Architectural Drawings ROOF
Transcription
Architectural Drawings ROOF
Architectural Drawings ROOF May 2015 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com For Latest Drawing Updates Visit: http://swdurethane.com/cms.php?id=250 Detail # Deck Penetrations QSR-020A QSR-020 QSR-018 QSR-015 TABLE OF CONTENTS Detail Description Page # Roof Drain without Mechanical Fastener..........................................3 Roof Drain with Mechanical Fastener................................................4 Deck Supported Penetration.............................................................5 Structural Member Through Roof Deck.............................................6 Dividers and Joints QSR-008 Typical Existing Area Divider Concrete Wall.......................................7 QSR-008A Typical Existing Area Divider..............................................................8 QSR-007 New Expansion Joint..........................................................................9 QSR-007A Remedial Expansion Joint............................................................... 10 QSR-111 Flat Roof to Shingles or Tile Tie-in.................................................. 11 Drains and Scuppers QSR-121 Sloped Roof and Crickets ............................................................... 12 QSR-122 Slope to Drain................................................................................. 13 QSR-020A Roof Drain without Mechanical Fastener....................................... 14 QSR-020 Roof Drain with Mechanical Fastener............................................. 15 QSR-021 Scupper Detail at Parapet Wall....................................................... 16 QSR-022 Overflow Scupper at Parapet Wall.................................................. 17 Equipment QSR-013 QSR-014 QSR-010 QSR-151 QSR-152 QSR-153 QSR-131 QSR-011 QSR-132 QSR-133 QSR-134 QSR-135 Prefabricated Metal Curb............................................................... 18 Wood Raised Curb.......................................................................... 19 Mechanical Equipment Support New and Remedial...................... 20 Roof Hatch...................................................................................... 21 Raised Curb for Skylight.................................................................. 22 Raised Curb for Down Draft Equipment.......................................... 23 Remedial Air Conditioner Treatment Using Slip Sheet................... 24 Equipment Support Stand.............................................................. 25 Existing Pitch Pan............................................................................ 26 Equipment Support on Existing Stand............................................ 27 Roof Equipment Protective Wall..................................................... 28 AC Duct Elbow................................................................................ 29 Fire Rated Assemblies QSR-146 2 Hour Class ‘A’ Concrete Deck Roof Assembly............................... 30 QSR-142 1-3 Hour Class ‘A’ Metal Deck Roof Assembly................................ 31 QSR-143 Class ‘A’ Metal Fluted Deck with Tape............................................ 32 QSR-147 Class ‘A’ Roof on Combustible Deck with Cementitous Coating..... 33 QSR-144 Class ‘B’ Roof on Combustible Deck............................................... 34 QSR-145 Class ‘B’ Roof on Combustible Deck with Polyiso Board................. 35 Raised Curbs QSR-013 QSR-014 QSR-151 QSR-152 QSR-153 Prefabricated Metal Curb............................................................... 36 Wood Raised Curb.......................................................................... 37 Roof Hatch...................................................................................... 38 Raised Curb for Skylight New and Remedial................................... 39 Raised Curb for Down Draft Equipment.......................................... 40 Walls QSR-003 QSR-003A QSR-002 QSR-001 QSR-001A QSR-161 QSR-162 QSR-163 QSR-164 QSR-165 QSR-021 QSR-022 Base Flashing for Wall-Supported Deck.......................................... 41 Base Flashing for Wall-Supported Deck Tall Wall............................ 42 Roof Edge Foam Stop...................................................................... 43 New Metal Parapet Cap.................................................................. 44 Existing Metal Parapet Cap............................................................. 45 Parapet Wall Detail......................................................................... 46 Foam and Coating Short Parapet Wall............................................ 47 New Flashing for Concrete Wall-Supported Deck........................... 48 Stucco Finish on Parapet Wall......................................................... 49 Mansard Wall Top and Bottom....................................................... 50 Scupper Detail at Parapet Wall....................................................... 51 Overflow Scupper at Parapet Wall.................................................. 52 QUIK-SHIELD COATING ROOF DECK QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM CLAMPING RING DRAIN BOWL SPARYED POLYURETHANE FOAM APPLIED TO BOWL DRAIN STRAINER AFFIXED TO ELASTOMERIC COATING WITH DAB OF COMPATIBLE SEALANT ROOF DRAIN WITHOUT MECHANICAL FASTENER (PREFERED) QSR-020A 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING EXISTING ROOF DECK QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM CLAMPING RING DRAIN BOWL QUIK-SHIELD COATING TO EXTEND INTO DRAIN BOWL INSTALL SEALANT UNDER CLAMPING RING BEFORE SECURING BOWL ROOF DRAIN WITH MECHANICAL FASTENER QSR-020 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com TEE TOP OR TYPICAL VENT PIPE EXTEND COATING ABOVE FOAM TERMINATION LINE QUIK-SHIELD COATING EXISTING ROOF JACK QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM NEW OR EXISTING ROOFING DECK SUPPORTED PENETRATION QSR-018 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM ROOF DECK PREPARE AS REQUIRED STRUCTURAL MEMBER THROUGH ROOF DECK QSR-015 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL CAP CONCRETE AREA DIVIDER QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM EXISTING ROOF DECK TYPICAL EXISTING AREA DIVIDER CONCRETE WALL QSR-008 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL CAP AREA DIVIDER QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM EXISTING ROOF DECK EXISTING ROOFING TYPICAL EXISTING AREA DIVIDER QSR-008A 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com JOINT CAP FLEXIBLE MEMBRANE EXPANSION JOINT 8” MINIMUM BETWEEN ROOF DECK AND JOINT CAP QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM NEW ROOF DECK NEW EXPANSION JOINT QSR-007 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com JOINT CAP FLEXIBLE MEMBRANE EXPANSION JOINT 8” MINIMUM BETWEEN ROOF DECK AND JOINT CAP QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM EXISTING ROOF DECK EXISTING ROOFING REMEDIAL EXPANSION JOINT QSR-007A 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com SHINGLES OR TILES QUIK-SHIELD COATING BASE SHEET WOOD DECK QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM NOTE: SPRAYED POLYURETAHNE FOAM MUST BE APPLIED BENEATH THE BASE SHEET FLAT ROOF TO SHINGLE OR TILE TIE-IN QSR-111 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com RAISED PERIMETER ROOF THROUGH EDGE SCUPPERS SL OP SHEET METAL CONDUCTOR HEAD E QUIK-SHIELD SPRAY FOAM APPLIED CRICKET QUIK-SHIELD COATING SL OP E QUIK-SHIELD SPRAY FOAM APPLIED CRICKET QUIK-SHIELD SPRAY POLYURETHANE FOAM 1” MINIMUM QUIK-SHIELD SPRAY POLYURETHANE TO INSIDE TOP OF PERIMETER EDGE NOTE: 1- SADDLES SHOULD BE LOCATED BETWEEN THROUGH-EDGE OR WALL SCUPPERS & CRICKETS ON THE HIGH SIDE OF CURBS 2- RAISED PERIMETER EDGES WHERE TAPERED CRICKETS ARE USED NECESSSITATE THE SPECIFICATION OF RELATIVELY WIDE (TALL) DIMENSIONAL LUMBER OR THE ERECTION OF FRAMED WALLS. SLOPED ROOF AND CRICKETS QSR-121 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com 1/4” PER FOOT MINIMUM SLOPE RECOMMENDED QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM 1/4” PER FOOT MINIMUM SLOPE RECOMMENDED ANY NEW OR EXISTING ROOF DECK STEEL JOISTS STEEL JOIST WALL SLOPE TO DRAIN QSR-122 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING ROOF DECK QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM CLAMPING RING DRAIN BOWL SPARYED POLYURETHANE FOAM APPLIED TO BOWL DRAIN STRAINER AFFIXED TO ELASTOMERIC COATING WITH DAB OF COMPATIBLE SEALANT ROOF DRAIN WITHOUT MECHANICAL FASTENER (PREFERED) QSR-020A 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING EXISTING ROOF DECK QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM CLAMPING RING DRAIN BOWL QUIK-SHIELD COATING TO EXTEND INTO DRAIN BOWL INSTALL SEALANT UNDER CLAMPING RING BEFORE SECURING BOWL ROOF DRAIN WITH MECHANICAL FASTENER QSR-020 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com INSTALL APPROPRIATE SEALANT ON ALL SIDES AND TOOL TO FACILITATE WATER RUNOFF QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM TAPERS TO END OF SCUPPER QUIK-SHIELD COATING TO EXTEND TO SIDES AND TOP OF SCUPPER WATER RUN-OFF THROUGH SCUPPER ROOF DECK STEEL JOISTS WALL (ANY WALL TYPE) SCUPPER INSTALL APPROPRIATE SEALANT ON ALL SIDES AND TOOL TO FACILITATE WATER RUNOFF SCUPPER DETAIL AT PARAPET WALL QSR-021 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com PROPERLY PREPARE METAL FLANGE BEFORE APPLYING SPRAY FOAM AND COATING TO ADHERE TO SURFACE EXTEND QUIK-SHIELD COATING ONTO SHEET METAL SCUPPER LINER 2” MIN. PAST SPRAY FOAM TERMINATION OPEN TO BE 2” ABOVE FINISHED SPRAY FOAM PREPARE WALL AS REQUIRED, PRIME IF NECESSARY SHEET METAL SCUPPER SOLDERED/ WELDED SECURED TO WALL QUIK-SHIELD COATING QUIK-SHIELD SPRAY POLYURETHANE FOAM 1” MINIMUM PARAPET WALL (ANY WALL TYPE) ROOF DECK (PREPARE AS REQUIRED) Note: This detail to be used only when roof deck is supported by the wall. OVERFLOW SCUPPER AT PARAPET WALL QSR-022 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL CURB PREPARE AS REQUIRED SEALING MATERIAL SHEET METAL FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE 8” MINIMUM TO TOP OF COATING QUIK SHIELD COATING QUIK SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM ROOF DECK PREPARE AS REQUIRED PREFABRICATED METAL CURB QSR-013 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com WOOD CURB PREPARE AS REQUIRED COUNTER FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM ROOF DECK PREPARE AS REQUIRED WOOD RAISED CURB QSR-014 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com STRUCTURAL FRAME W ID TH OF EQ UI PM EN T (S EE CH AR T) HEIGHT OF LEGS PIPE COLUMN ATTACHED TO STRUCTURAL SUPPORT QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM WIDTH OF EQUIPMENT HEIGHT OF LEGS UP TO 24” 14” 25” TO 36” 18” 36” TO 48” 24” 48” TO 60” 30” 60 AND WIDER 48” MECHANICAL EQUIPMENT SUPPORT NEW AND REMEDIAL QSR-010 07-2012 NEW OR EXISTING DECK SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com ROOF HATCH ASSEMBLY INTEGRATED HATCH CURB FLASHING EXTEND COATING INTO INTEGRATED HATCH CURB FLASHING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM ROOF HATCH QSR-151 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com SKYLIGHT COUNTER FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM WOOD OR METAL CURB PREPARE AS REQUIRED ROOF DECK PREPARE AS REQUIRED RAISED CURB FOR SKYLIGHT QSR-152 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com WOOD OR METAL CURB PREPARE AS REQUIRED ROOF EQUIPMENT COUNTER FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK-SHIELD SPRAY POLYURETHANE FOAM 1.5” MINIMUM ROOF DECK PREPARE AS REQUIRED RAISED CURB FOR DOWN DRAFT EQUIPMENT QSR-153 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com TREATED WOOD EQUIPMENT SUPPORTS QUIK-SHIELD COATING PIPE SUPPORT SLIP-SHEET MEMBRANE PLACED BENEATH ROOF EQUIPMENT AND COVERED IN SPRAYED POLYURTHANE FOAM TO MATCH ROOF QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM DECK AND STEEL STRUCTURE REMEDIAL AIR CONDITIONER TREATMENT USING SLIP SHEET QSR-131 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com STRUCTURAL FRAME SUPPORT COLUMN PRIME SUPPORT COLUMN BEFORE APPLYING SPRAY FOAM 8” MIN. FLASHING HEIGHT QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM FILL GAPS WITH SPRAY FOAM EQUIPMENT SUPPORT STAND QSR-011 07-2012 ROOF DECK - PREPARE AS REQUIRED SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com 8” MINIMUM TO TOP OF COATING QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM ASPHALT EXISTING PITCH PAN FLASHING EXISTING PITCH PAN QSR-132 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com ISOLATED BASE PLATE METAL CAP FLASHING CONCRETE CURB DENS DECK OR SHEATHING QUIK-SHIELD COATING ROOF DECK QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM EQUIPMENT SUPPORT ON EXISTING STAND QSR-133 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com PROTECTIVE METAL WALL ROOF EQUIPMENT QUIK SHIELD COATING STEEL COLUMNS NEW OR EXISTING DECK / SUBSTRATE QUIK SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM ROOF EQUIPMENT PROTECTIVE WALL QSR-134 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com FASTENING PLATE WITH SCREWS EXPOSED FOR A.C. ACCESS QUIK-SHIELD COATING A.C. DUCT ELBOW INTO BUILDING COVERED WITH QUIK-SHIELD POLYURETHANE FOAM 1” MINIMUM AIR CONDITIONING UNIT METAL PLATE ROOF DECK PREPARE AS REQUIRED QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM AC DUCT ELBOW QSR-135 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM CONCRETE DECK QUIK-SHIELD PRIMER SEE UL DESIGN NO. P904 FOR FIRE RATING DETAILS 2 - HOUR - CLASS ‘A’ CONCRETE DECK ROOF ASSEMBLY QSR-146 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM MECHANICALLY OR ADHESIVE- FASTENED 5/8” TYPE X GYPSUM BOARD STOCK FLUTED METAL DECK FIRE PROTECTIVE CEMENTITOUS MIXTURE SEE UL DESIGN NO. P733 AND P826 FOR FIRE RATING DETAILS 1 - 3 HOUR - CLASS ‘A’ METAL DECK ROOF ASSEBMLY QSR-142 05-2015 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM TELGRAPHING OF TAPE CAN OCCUR 3” MAX QUIK-SHIELD PRIMER 4” CLEAR ADHESIVE TAPE FLUTED METAL DECK SEE UL CONSTRUCTION NO. 206 FOR DETAILS CLASS ‘A’ METAL FLUTED DECK WITH TAPE QSR-143 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD CEMENTITOUS COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM COMBUSTIBLE WOOD DECK SEE UL ROOFING MATERIALS & SYSTEMS - SWD URETHANE - CLASS ‘A’ ASSEMBLY 35 FOR DETAILS CLASS ‘A’ ROOF ON COMBUSTIBLE DECK WITH CEMENTITOUS COATING QSR-147 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM COMBUSTIBLE WOOD DECK CLASS ‘B’ ROOF ON COMBUSTIBLE DECK QSR-144 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM COMBUSTIBLE WOOD DECK POLYISO BOARD CLASS ‘B’ ROOF ON COMBUSTIBLE DECK WITH POLYISO BOARD QSR-145 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL CURB PREPARE AS REQUIRED SEALING MATERIAL SHEET METAL FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE 8” MINIMUM TO TOP OF COATING QUIK SHIELD COATING QUIK SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM ROOF DECK PREPARE AS REQUIRED PREFABRICATED METAL CURB QSR-013 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com WOOD CURB PREPARE AS REQUIRED COUNTER FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM ROOF DECK PREPARE AS REQUIRED WOOD RAISED CURB QSR-014 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com ROOF HATCH ASSEMBLY INTEGRATED HATCH CURB FLASHING EXTEND COATING INTO INTEGRATED HATCH CURB FLASHING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM ROOF HATCH QSR-151 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com SKYLIGHT COUNTER FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM WOOD OR METAL CURB PREPARE AS REQUIRED ROOF DECK PREPARE AS REQUIRED RAISED CURB FOR SKYLIGHT QSR-152 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com WOOD OR METAL CURB PREPARE AS REQUIRED ROOF EQUIPMENT COUNTER FLASHING 8” MIN. FLASHING HEIGHT FOAM COATING TO EXTEND TO TOP OF OUTSIDE EDGE QUIK-SHIELD COATING QUIK-SHIELD SPRAY POLYURETHANE FOAM 1.5” MINIMUM ROOF DECK PREPARE AS REQUIRED RAISED CURB FOR DOWN DRAFT EQUIPMENT QSR-153 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com 4” MINIMUM TO TOP OF COATING EXISTING WALL (ANY TYPE) QUIK-SHIELD COATING (SELF FLASHING) PRIME CONCRETE BEFORE APPLYING SPRAYED POLYURETHANE FOAM QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM NEW ROOF DECK PREPARE AS REQUIRED NOTE: THIS DETAIL TO BE USED ONLY WHEN DECK IS SUPPORTED BY THE WALL BASE FLASHING FOR WALL-SUPPORTED DECK QSR-003 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING SELF FLASHING QUIK-SHIELD SPRAY POLYURETHANE FOAM TO MAINTAIN 1” MINIMUM FOR HEIGHT OF WALL EXISTING WALL HEIGHT VARIABLE PRIME CONCRETE BEFORE APPLYING SPRAYED POLYURETHANE FOAM QUIK SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM NEW ROOF DECK PREPARE AS REQUIRED NOTE: THIS DETAIL TO BE USED ONLY WHEN DECK IS SUPPORTED BY THE WALL BASE FLASHING WALL SUPPORTED DECK TALL WALL QSR-003A 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM TYPICAL FOAM STOP TAPER TO FOAM STOP HEIGHT EXISTING DECK EXISTING WALL ROOF EDGE FOAM STOP QSR-002 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL CAP WEATHER PROOF MEMBRANE 4” MINIMUM TO TOP OF COATING NEW WALL (ANY WALL TYPE) QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM ROOF DECK PREPARE AS REQUIRED NOTE: FREE HEIGHT SHOULD BE 8” ABOVE ROOF SURFACE THIS DETAIL SHOULD BE USED ONLY WHEN THE DECK IS SUPPORTED BY THE WALL NEW METAL PARAPET CAP QSR-001 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL CAP WEATHER PROOF MEMBRANE 4” MINIMUM TO TOP OF COATING EXISTING WALL (ANY WALL TYPE) QUIK-SHIELD COATING QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM EXISTING ROOFING EXISTING ROOF DECK NOTE: THIS IS A WALL SUPPORTED BY DECK EXISTING METAL PARAPET CAP QSR-001A 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com METAL PARAPET CAP EXTEND SPRAY FOAM AND TOP COAT UP WALL ROOF DECK QUIK-SHIELD COATING ON ROOF AND WALL STEEL JOISTS WALL QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM NEW OR EXISTING ROOF DECK STEEL JOISTS PARAPET WALL DETAIL QSR-161 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com SHEET METAL EDGE FLASHING QUIK-SHIELD COATING TO UNDER FLASHING METAL CAP QUIK-SHIELD COATING CONTINUOUS ON ROOF FOAM STOP PARAPET WALL VENT PIPE GALVANIZED ROOF JACK NEW OR EXISTING DECK / SUBSTRATE DRAIN FOAM AND COATING SHORT PARAPET WALL QSR-162 07-2012 QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com Z-BAR COUNTER-FLASHING INSTALLED OVER 2” X 2” WOOD STOP OR EQUIVALENT J-WEEP FLASHING QUIK-SHIELD COATING SELF FLASHING EXISTING WALL QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM NEW ROOF DECK PREPARE AS REQUIRED NOTE: 1- WOOD STOP BY FRAMES 2- THIS DETAIL TO BE USED ONLY WHEN THE DECK IS SUPPORTED BY THE WALL NEW FLASHING FOR CONCRETE WALL-SUPPORTED DECK QSR-163 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com EXISTING WALL STUCCO FINISHED SYSTEM CORROSION RESISTANT FLASHING Z-BAR COUNTER-FLASHING INSTALLED OVER 2” X 2” WOOD STOP OR EQUIVALENT J-WEEP FLASHING QUIK-SHIELD COATING NEW ROOF DECK STUCCO FINISH ON PARAPET WALL QSR-164 07-2012 QUIK SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM 1” MINIMUM SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com MANSARD ROOF QUIK-SHIELD COATING TRUSS WALL STUD WALL SHEATING QUIK-SHIELD COATING CONTINUOUS ON ROOF ROOF DECKING MANSARD WALL TOP AND BOTTOM QSR-165 07-2012 QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 1” MINIMUM SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com INSTALL APPROPRIATE SEALANT ON ALL SIDES AND TOOL TO FACILITATE WATER RUNOFF QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM TAPERS TO END OF SCUPPER QUIK-SHIELD COATING TO EXTEND TO SIDES AND TOP OF SCUPPER WATER RUN-OFF THROUGH SCUPPER ROOF DECK STEEL JOISTS WALL (ANY WALL TYPE) SCUPPER INSTALL APPROPRIATE SEALANT ON ALL SIDES AND TOOL TO FACILITATE WATER RUNOFF SCUPPER DETAIL AT PARAPET WALL QSR-021 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com PROPERLY PREPARE METAL FLANGE BEFORE APPLYING SPRAY FOAM AND COATING TO ADHERE TO SURFACE EXTEND QUIK-SHIELD COATING ONTO SHEET METAL SCUPPER LINER 2” MIN. PAST SPRAY FOAM TERMINATION OPEN TO BE 2” ABOVE FINISHED SPRAY FOAM PREPARE WALL AS REQUIRED, PRIME IF NECESSARY SHEET METAL SCUPPER SOLDERED/ WELDED SECURED TO WALL QUIK-SHIELD COATING QUIK-SHIELD SPRAY POLYURETHANE FOAM 1” MINIMUM PARAPET WALL (ANY WALL TYPE) ROOF DECK (PREPARE AS REQUIRED) Note: This detail to be used only when roof deck is supported by the wall. OVERFLOW SCUPPER AT PARAPET WALL QSR-022 07-2012 SWD Urethane Mesa, Arizona 800-828-1394 swdurethane.com