Architectural Drawings ROOF

Transcription

Architectural Drawings ROOF
Architectural Drawings
ROOF
May 2015
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
For Latest Drawing Updates Visit: http://swdurethane.com/cms.php?id=250
Detail #
Deck Penetrations
QSR-020A
QSR-020
QSR-018
QSR-015
TABLE OF CONTENTS
Detail Description
Page #
Roof Drain without Mechanical Fastener..........................................3
Roof Drain with Mechanical Fastener................................................4
Deck Supported Penetration.............................................................5
Structural Member Through Roof Deck.............................................6
Dividers and Joints
QSR-008
Typical Existing Area Divider Concrete Wall.......................................7
QSR-008A
Typical Existing Area Divider..............................................................8
QSR-007
New Expansion Joint..........................................................................9
QSR-007A
Remedial Expansion Joint............................................................... 10
QSR-111
Flat Roof to Shingles or Tile Tie-in.................................................. 11
Drains and Scuppers
QSR-121
Sloped Roof and Crickets ............................................................... 12
QSR-122
Slope to Drain................................................................................. 13
QSR-020A
Roof Drain without Mechanical Fastener....................................... 14
QSR-020
Roof Drain with Mechanical Fastener............................................. 15
QSR-021
Scupper Detail at Parapet Wall....................................................... 16
QSR-022
Overflow Scupper at Parapet Wall.................................................. 17
Equipment
QSR-013
QSR-014
QSR-010
QSR-151
QSR-152
QSR-153
QSR-131
QSR-011
QSR-132
QSR-133
QSR-134
QSR-135
Prefabricated Metal Curb............................................................... 18
Wood Raised Curb.......................................................................... 19
Mechanical Equipment Support New and Remedial...................... 20
Roof Hatch...................................................................................... 21
Raised Curb for Skylight.................................................................. 22
Raised Curb for Down Draft Equipment.......................................... 23
Remedial Air Conditioner Treatment Using Slip Sheet................... 24
Equipment Support Stand.............................................................. 25
Existing Pitch Pan............................................................................ 26
Equipment Support on Existing Stand............................................ 27
Roof Equipment Protective Wall..................................................... 28
AC Duct Elbow................................................................................ 29
Fire Rated Assemblies
QSR-146
2 Hour Class ‘A’ Concrete Deck Roof Assembly............................... 30
QSR-142
1-3 Hour Class ‘A’ Metal Deck Roof Assembly................................ 31
QSR-143
Class ‘A’ Metal Fluted Deck with Tape............................................ 32
QSR-147
Class ‘A’ Roof on Combustible Deck with Cementitous Coating..... 33
QSR-144
Class ‘B’ Roof on Combustible Deck............................................... 34
QSR-145
Class ‘B’ Roof on Combustible Deck with Polyiso Board................. 35
Raised Curbs
QSR-013
QSR-014
QSR-151
QSR-152
QSR-153
Prefabricated Metal Curb............................................................... 36
Wood Raised Curb.......................................................................... 37
Roof Hatch...................................................................................... 38
Raised Curb for Skylight New and Remedial................................... 39
Raised Curb for Down Draft Equipment.......................................... 40
Walls
QSR-003
QSR-003A
QSR-002
QSR-001
QSR-001A
QSR-161
QSR-162
QSR-163
QSR-164
QSR-165
QSR-021
QSR-022
Base Flashing for Wall-Supported Deck.......................................... 41
Base Flashing for Wall-Supported Deck Tall Wall............................ 42
Roof Edge Foam Stop...................................................................... 43
New Metal Parapet Cap.................................................................. 44
Existing Metal Parapet Cap............................................................. 45
Parapet Wall Detail......................................................................... 46
Foam and Coating Short Parapet Wall............................................ 47
New Flashing for Concrete Wall-Supported Deck........................... 48
Stucco Finish on Parapet Wall......................................................... 49
Mansard Wall Top and Bottom....................................................... 50
Scupper Detail at Parapet Wall....................................................... 51
Overflow Scupper at Parapet Wall.................................................. 52
QUIK-SHIELD
COATING
ROOF DECK
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
CLAMPING RING
DRAIN BOWL
SPARYED POLYURETHANE
FOAM APPLIED TO BOWL
DRAIN STRAINER
AFFIXED TO
ELASTOMERIC COATING
WITH DAB OF COMPATIBLE
SEALANT
ROOF DRAIN WITHOUT
MECHANICAL FASTENER (PREFERED)
QSR-020A 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD
COATING
EXISTING ROOF
DECK
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
CLAMPING RING
DRAIN BOWL
QUIK-SHIELD COATING
TO EXTEND INTO
DRAIN BOWL
INSTALL SEALANT
UNDER CLAMPING
RING BEFORE SECURING
BOWL
ROOF DRAIN WITH MECHANICAL FASTENER
QSR-020 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
TEE TOP OR TYPICAL VENT PIPE
EXTEND COATING ABOVE FOAM
TERMINATION LINE
QUIK-SHIELD COATING
EXISTING ROOF JACK
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
NEW OR EXISTING
ROOFING
DECK SUPPORTED PENETRATION
QSR-018 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
ROOF DECK PREPARE AS REQUIRED
STRUCTURAL MEMBER THROUGH
ROOF DECK
QSR-015 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL CAP
CONCRETE
AREA DIVIDER
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
EXISTING ROOF DECK
TYPICAL EXISTING AREA DIVIDER
CONCRETE WALL
QSR-008 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL CAP
AREA DIVIDER
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
EXISTING ROOF DECK
EXISTING ROOFING
TYPICAL EXISTING AREA DIVIDER
QSR-008A 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
JOINT CAP
FLEXIBLE MEMBRANE
EXPANSION JOINT
8” MINIMUM BETWEEN
ROOF DECK AND JOINT CAP
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
NEW ROOF DECK
NEW EXPANSION JOINT
QSR-007 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
JOINT CAP
FLEXIBLE MEMBRANE
EXPANSION JOINT
8” MINIMUM BETWEEN
ROOF DECK AND JOINT CAP
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
EXISTING ROOF DECK
EXISTING ROOFING
REMEDIAL EXPANSION JOINT
QSR-007A 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
SHINGLES OR TILES
QUIK-SHIELD COATING
BASE SHEET
WOOD DECK
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
NOTE:
SPRAYED POLYURETAHNE FOAM MUST BE APPLIED BENEATH THE BASE SHEET
FLAT ROOF TO SHINGLE OR TILE TIE-IN
QSR-111 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
RAISED PERIMETER ROOF
THROUGH EDGE SCUPPERS
SL
OP
SHEET METAL
CONDUCTOR HEAD
E
QUIK-SHIELD SPRAY FOAM
APPLIED CRICKET
QUIK-SHIELD COATING
SL
OP
E
QUIK-SHIELD
SPRAY FOAM
APPLIED
CRICKET
QUIK-SHIELD SPRAY
POLYURETHANE FOAM 1”
MINIMUM
QUIK-SHIELD SPRAY
POLYURETHANE TO
INSIDE TOP OF
PERIMETER EDGE
NOTE:
1- SADDLES SHOULD BE LOCATED BETWEEN THROUGH-EDGE OR
WALL SCUPPERS & CRICKETS ON THE HIGH SIDE OF CURBS
2- RAISED PERIMETER EDGES WHERE TAPERED CRICKETS ARE USED
NECESSSITATE THE SPECIFICATION OF RELATIVELY WIDE (TALL)
DIMENSIONAL LUMBER OR THE ERECTION OF FRAMED WALLS.
SLOPED ROOF AND CRICKETS
QSR-121 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
1/4” PER FOOT MINIMUM
SLOPE RECOMMENDED
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
1/4” PER FOOT MINIMUM
SLOPE RECOMMENDED
ANY NEW OR EXISTING
ROOF DECK
STEEL JOISTS
STEEL JOIST
WALL
SLOPE TO DRAIN
QSR-122 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD
COATING
ROOF DECK
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
CLAMPING RING
DRAIN BOWL
SPARYED POLYURETHANE
FOAM APPLIED TO BOWL
DRAIN STRAINER
AFFIXED TO
ELASTOMERIC COATING
WITH DAB OF COMPATIBLE
SEALANT
ROOF DRAIN WITHOUT
MECHANICAL FASTENER (PREFERED)
QSR-020A 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD
COATING
EXISTING ROOF
DECK
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
CLAMPING RING
DRAIN BOWL
QUIK-SHIELD COATING
TO EXTEND INTO
DRAIN BOWL
INSTALL SEALANT
UNDER CLAMPING
RING BEFORE SECURING
BOWL
ROOF DRAIN WITH MECHANICAL FASTENER
QSR-020 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
INSTALL APPROPRIATE
SEALANT ON ALL SIDES
AND TOOL TO FACILITATE
WATER RUNOFF
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM TAPERS TO END OF
SCUPPER
QUIK-SHIELD COATING
TO EXTEND TO SIDES
AND TOP OF SCUPPER
WATER RUN-OFF
THROUGH SCUPPER
ROOF DECK
STEEL JOISTS
WALL
(ANY WALL TYPE)
SCUPPER
INSTALL APPROPRIATE
SEALANT ON ALL SIDES
AND TOOL TO FACILITATE
WATER RUNOFF
SCUPPER DETAIL AT PARAPET WALL
QSR-021 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
PROPERLY PREPARE METAL
FLANGE BEFORE APPLYING
SPRAY FOAM AND COATING
TO ADHERE TO SURFACE
EXTEND QUIK-SHIELD
COATING ONTO SHEET
METAL SCUPPER LINER
2” MIN. PAST SPRAY
FOAM TERMINATION
OPEN TO BE 2” ABOVE
FINISHED SPRAY
FOAM
PREPARE WALL AS
REQUIRED, PRIME IF
NECESSARY
SHEET METAL SCUPPER
SOLDERED/ WELDED
SECURED TO WALL
QUIK-SHIELD COATING
QUIK-SHIELD SPRAY
POLYURETHANE FOAM
1” MINIMUM
PARAPET WALL
(ANY WALL TYPE)
ROOF DECK
(PREPARE AS REQUIRED)
Note:
This detail to be used only when roof deck is supported by the wall.
OVERFLOW SCUPPER AT PARAPET WALL
QSR-022 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL CURB
PREPARE AS REQUIRED
SEALING MATERIAL
SHEET METAL FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
8” MINIMUM TO
TOP OF COATING
QUIK SHIELD COATING
QUIK SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
ROOF DECK PREPARE AS REQUIRED
PREFABRICATED METAL CURB
QSR-013 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
WOOD CURB
PREPARE AS REQUIRED
COUNTER FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
ROOF DECK PREPARE AS REQUIRED
WOOD RAISED CURB
QSR-014 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
STRUCTURAL FRAME
W
ID
TH
OF
EQ
UI
PM
EN
T
(S
EE
CH
AR
T)
HEIGHT OF LEGS
PIPE COLUMN ATTACHED TO
STRUCTURAL SUPPORT
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
WIDTH OF EQUIPMENT
HEIGHT OF LEGS
UP TO 24”
14”
25” TO 36”
18”
36” TO 48”
24”
48” TO 60”
30”
60 AND WIDER
48”
MECHANICAL EQUIPMENT SUPPORT
NEW AND REMEDIAL
QSR-010 07-2012
NEW OR EXISTING DECK
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
ROOF HATCH
ASSEMBLY
INTEGRATED HATCH
CURB FLASHING
EXTEND COATING
INTO INTEGRATED
HATCH CURB FLASHING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
ROOF HATCH
QSR-151 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
SKYLIGHT
COUNTER FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
WOOD OR METAL CURB
PREPARE AS REQUIRED
ROOF DECK PREPARE AS REQUIRED
RAISED CURB FOR SKYLIGHT
QSR-152 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
WOOD OR METAL CURB
PREPARE AS REQUIRED
ROOF EQUIPMENT
COUNTER FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK-SHIELD SPRAY
POLYURETHANE FOAM
1.5” MINIMUM
ROOF DECK PREPARE AS REQUIRED
RAISED CURB
FOR DOWN DRAFT EQUIPMENT
QSR-153 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
TREATED WOOD
EQUIPMENT SUPPORTS
QUIK-SHIELD
COATING
PIPE SUPPORT
SLIP-SHEET MEMBRANE
PLACED BENEATH ROOF
EQUIPMENT AND COVERED
IN SPRAYED POLYURTHANE
FOAM TO MATCH ROOF
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
DECK AND STEEL
STRUCTURE
REMEDIAL AIR CONDITIONER TREATMENT
USING SLIP SHEET
QSR-131 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
STRUCTURAL FRAME
SUPPORT COLUMN
PRIME SUPPORT COLUMN
BEFORE APPLYING SPRAY
FOAM
8” MIN. FLASHING HEIGHT
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
FILL GAPS WITH SPRAY FOAM
EQUIPMENT SUPPORT STAND
QSR-011 07-2012
ROOF DECK - PREPARE AS
REQUIRED
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
8” MINIMUM
TO TOP OF
COATING
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE
FOAM 1” MINIMUM
ASPHALT
EXISTING PITCH PAN
FLASHING
EXISTING PITCH PAN
QSR-132 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
ISOLATED BASE PLATE
METAL CAP FLASHING
CONCRETE CURB
DENS DECK OR SHEATHING
QUIK-SHIELD COATING
ROOF DECK
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
EQUIPMENT SUPPORT ON EXISTING STAND
QSR-133 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
PROTECTIVE METAL
WALL
ROOF EQUIPMENT
QUIK SHIELD COATING
STEEL COLUMNS
NEW OR EXISTING
DECK / SUBSTRATE
QUIK SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
ROOF EQUIPMENT
PROTECTIVE WALL
QSR-134 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
FASTENING PLATE WITH
SCREWS EXPOSED FOR
A.C. ACCESS
QUIK-SHIELD COATING
A.C. DUCT ELBOW INTO
BUILDING COVERED WITH
QUIK-SHIELD POLYURETHANE
FOAM 1” MINIMUM
AIR CONDITIONING UNIT
METAL PLATE
ROOF DECK PREPARE AS REQUIRED
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
AC DUCT ELBOW
QSR-135 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
CONCRETE DECK
QUIK-SHIELD PRIMER
SEE UL DESIGN NO. P904 FOR FIRE RATING DETAILS
2 - HOUR - CLASS ‘A’ CONCRETE DECK
ROOF ASSEMBLY
QSR-146 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
MECHANICALLY OR ADHESIVE- FASTENED
5/8” TYPE X GYPSUM BOARD STOCK
FLUTED METAL DECK
FIRE PROTECTIVE
CEMENTITOUS MIXTURE
SEE UL DESIGN NO. P733 AND P826 FOR FIRE RATING DETAILS
1 - 3 HOUR - CLASS ‘A’ METAL DECK
ROOF ASSEBMLY
QSR-142 05-2015
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
TELGRAPHING OF TAPE CAN OCCUR
3” MAX
QUIK-SHIELD PRIMER
4” CLEAR ADHESIVE TAPE
FLUTED METAL DECK
SEE UL CONSTRUCTION NO. 206 FOR DETAILS
CLASS ‘A’ METAL FLUTED DECK
WITH TAPE
QSR-143 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD CEMENTITOUS
COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
COMBUSTIBLE WOOD DECK
SEE UL ROOFING MATERIALS & SYSTEMS - SWD URETHANE - CLASS ‘A’ ASSEMBLY 35 FOR DETAILS
CLASS ‘A’ ROOF ON COMBUSTIBLE DECK
WITH CEMENTITOUS COATING
QSR-147 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
COMBUSTIBLE WOOD DECK
CLASS ‘B’ ROOF ON COMBUSTIBLE DECK
QSR-144 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
COMBUSTIBLE WOOD DECK
POLYISO BOARD
CLASS ‘B’ ROOF ON COMBUSTIBLE DECK
WITH POLYISO BOARD
QSR-145 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL CURB
PREPARE AS REQUIRED
SEALING MATERIAL
SHEET METAL FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
8” MINIMUM TO
TOP OF COATING
QUIK SHIELD COATING
QUIK SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
ROOF DECK PREPARE AS REQUIRED
PREFABRICATED METAL CURB
QSR-013 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
WOOD CURB
PREPARE AS REQUIRED
COUNTER FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
ROOF DECK PREPARE AS REQUIRED
WOOD RAISED CURB
QSR-014 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
ROOF HATCH
ASSEMBLY
INTEGRATED HATCH
CURB FLASHING
EXTEND COATING
INTO INTEGRATED
HATCH CURB FLASHING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
ROOF HATCH
QSR-151 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
SKYLIGHT
COUNTER FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
WOOD OR METAL CURB
PREPARE AS REQUIRED
ROOF DECK PREPARE AS REQUIRED
RAISED CURB FOR SKYLIGHT
QSR-152 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
WOOD OR METAL CURB
PREPARE AS REQUIRED
ROOF EQUIPMENT
COUNTER FLASHING
8” MIN.
FLASHING HEIGHT
FOAM COATING TO EXTEND
TO TOP OF OUTSIDE EDGE
QUIK-SHIELD COATING
QUIK-SHIELD SPRAY
POLYURETHANE FOAM
1.5” MINIMUM
ROOF DECK PREPARE AS REQUIRED
RAISED CURB
FOR DOWN DRAFT EQUIPMENT
QSR-153 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
4” MINIMUM TO
TOP OF COATING
EXISTING WALL
(ANY TYPE)
QUIK-SHIELD COATING
(SELF FLASHING)
PRIME CONCRETE BEFORE
APPLYING SPRAYED
POLYURETHANE FOAM
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
NEW ROOF DECK PREPARE AS REQUIRED
NOTE:
THIS DETAIL TO BE USED ONLY WHEN DECK IS SUPPORTED BY THE WALL
BASE FLASHING FOR
WALL-SUPPORTED DECK
QSR-003 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
SELF FLASHING
QUIK-SHIELD SPRAY
POLYURETHANE FOAM TO
MAINTAIN 1” MINIMUM
FOR HEIGHT OF WALL
EXISTING WALL
HEIGHT VARIABLE
PRIME CONCRETE BEFORE
APPLYING SPRAYED
POLYURETHANE FOAM
QUIK SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
NEW ROOF DECK PREPARE AS REQUIRED
NOTE:
THIS DETAIL TO BE USED ONLY WHEN DECK IS SUPPORTED BY THE WALL
BASE FLASHING WALL SUPPORTED DECK
TALL WALL
QSR-003A 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
TYPICAL FOAM
STOP
TAPER TO FOAM STOP HEIGHT
EXISTING DECK
EXISTING WALL
ROOF EDGE FOAM STOP
QSR-002 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL CAP
WEATHER PROOF
MEMBRANE
4” MINIMUM TO
TOP OF COATING
NEW WALL
(ANY WALL TYPE)
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
ROOF DECK PREPARE AS REQUIRED
NOTE:
FREE HEIGHT SHOULD BE 8” ABOVE ROOF SURFACE
THIS DETAIL SHOULD BE USED ONLY WHEN THE DECK IS SUPPORTED BY THE WALL
NEW METAL PARAPET CAP
QSR-001 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL CAP
WEATHER PROOF
MEMBRANE
4” MINIMUM TO
TOP OF COATING
EXISTING WALL
(ANY WALL TYPE)
QUIK-SHIELD COATING
QUIK-SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
EXISTING ROOFING
EXISTING ROOF DECK
NOTE:
THIS IS A WALL SUPPORTED BY DECK
EXISTING METAL PARAPET CAP
QSR-001A 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
METAL PARAPET CAP
EXTEND SPRAY FOAM AND
TOP COAT UP WALL
ROOF DECK
QUIK-SHIELD COATING
ON ROOF AND WALL
STEEL JOISTS
WALL
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
NEW OR EXISTING ROOF DECK
STEEL JOISTS
PARAPET WALL DETAIL
QSR-161 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
SHEET METAL EDGE FLASHING
QUIK-SHIELD COATING TO UNDER FLASHING
METAL CAP
QUIK-SHIELD COATING
CONTINUOUS ON ROOF
FOAM
STOP
PARAPET
WALL
VENT PIPE
GALVANIZED ROOF
JACK
NEW OR EXISTING
DECK / SUBSTRATE
DRAIN
FOAM AND COATING
SHORT PARAPET WALL
QSR-162 07-2012
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
Z-BAR COUNTER-FLASHING INSTALLED
OVER 2” X 2” WOOD STOP OR
EQUIVALENT J-WEEP FLASHING
QUIK-SHIELD COATING
SELF FLASHING
EXISTING WALL
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
NEW ROOF DECK PREPARE AS REQUIRED
NOTE:
1- WOOD STOP BY FRAMES
2- THIS DETAIL TO BE USED ONLY WHEN THE DECK IS SUPPORTED BY THE WALL
NEW FLASHING FOR CONCRETE
WALL-SUPPORTED DECK
QSR-163 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
EXISTING WALL
STUCCO FINISHED SYSTEM
CORROSION
RESISTANT
FLASHING
Z-BAR COUNTER-FLASHING INSTALLED
OVER 2” X 2” WOOD STOP OR
EQUIVALENT J-WEEP FLASHING
QUIK-SHIELD
COATING
NEW ROOF DECK
STUCCO FINISH ON PARAPET WALL
QSR-164 07-2012
QUIK SHIELD CLOSED-CELL
SPRAY POLYURETHANE FOAM
1” MINIMUM
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
MANSARD ROOF
QUIK-SHIELD COATING
TRUSS
WALL STUD
WALL SHEATING
QUIK-SHIELD COATING
CONTINUOUS ON ROOF
ROOF DECKING
MANSARD WALL
TOP AND BOTTOM
QSR-165 07-2012
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM 1” MINIMUM
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
INSTALL APPROPRIATE
SEALANT ON ALL SIDES
AND TOOL TO FACILITATE
WATER RUNOFF
QUIK-SHIELD CLOSED-CELL
SPRAYED POLYURETHANE
FOAM TAPERS TO END OF
SCUPPER
QUIK-SHIELD COATING
TO EXTEND TO SIDES
AND TOP OF SCUPPER
WATER RUN-OFF
THROUGH SCUPPER
ROOF DECK
STEEL JOISTS
WALL
(ANY WALL TYPE)
SCUPPER
INSTALL APPROPRIATE
SEALANT ON ALL SIDES
AND TOOL TO FACILITATE
WATER RUNOFF
SCUPPER DETAIL AT PARAPET WALL
QSR-021 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com
PROPERLY PREPARE METAL
FLANGE BEFORE APPLYING
SPRAY FOAM AND COATING
TO ADHERE TO SURFACE
EXTEND QUIK-SHIELD
COATING ONTO SHEET
METAL SCUPPER LINER
2” MIN. PAST SPRAY
FOAM TERMINATION
OPEN TO BE 2” ABOVE
FINISHED SPRAY
FOAM
PREPARE WALL AS
REQUIRED, PRIME IF
NECESSARY
SHEET METAL SCUPPER
SOLDERED/ WELDED
SECURED TO WALL
QUIK-SHIELD COATING
QUIK-SHIELD SPRAY
POLYURETHANE FOAM
1” MINIMUM
PARAPET WALL
(ANY WALL TYPE)
ROOF DECK
(PREPARE AS REQUIRED)
Note:
This detail to be used only when roof deck is supported by the wall.
OVERFLOW SCUPPER AT PARAPET WALL
QSR-022 07-2012
SWD Urethane
Mesa, Arizona
800-828-1394
swdurethane.com