Technical details 2700 / 2750 / 2710

Transcription

Technical details 2700 / 2750 / 2710
10
Technical details
Compact design with integrated controller
scanCONTROL 2700/2710 combines technology and performance in a
single device, providing the dual benefits of an integrated controller and
compact dimensions.
2700 / 2750 / 2710
- z-axis measuring range up to 300mm
- x-axis measuring range up to 148mm
- Profile frequency up to 2,000Hz
Multiple scanner applications
- Measuring rate up to 1,280,000 points per second
For many applications, it is necessary to measure or acquire data simultaneously using multiple sensors. With its combination of compact design, simple wiring and attractive price, scanCONTROL 2700 / 2710 is
ideally suited to performing multi scanner applications.
- z-axis reference resolution <4μm
- Resolution x-axis up to 640 points
Alternating laser toggle
scanCONTROL 2700
When using multiple sensors for a measuring task, it is sometimes necessary to work with overlapping laser lines. To rule out optical interference,
the scanCONTROL 2700 and 2750 have a special synchronisation feature. This „180° phase shift“ mode provides an alternating laser ON/OFF.
The laser beam of one sensor is switched off for a fraction of a second
while the other sensor performs measurements. This is done automatically and has no effect on the overall measurement frequency.
The scanCONTROL 2700 sensors are the most economic sensors for
static and dynamic applications. The sensor provides a profile frequency
of 100Hz and up to 64,000 measuring points per second.
scanCONTROL 2750
The scanCONTROL 2750 sensors offer everything you need for advanced high speed 3D applications. Up to 1,280,000 points per second with
a profile frequency of up to 2,000Hz are possible using these sensors.
Extended measuring ranges for large targets
Extended measuring ranges are available for larger objects. Using software, the user can switch over from the standard range to the extended
range. To document the measuring ranges, each sensor is equipped with
a calibration protocol.
Protective cover plate for harsh environments
A protective cover plate is available for harsh industrial environments.
This plate can be equipped with a purge air system. The cover plate is
attached to the sensor and has a protective window, through which the
beam passes through.
scanCONTROL 2710
The smart series scanCONTROL 2710 offers a Plug & Play solution with
integrated controller for simple measurement tasks. The sensor design is
identical to the 2700 and 2750 series.
11
Compact and HighSpeed: Calibrated profile data
The scanCONTROL 2700 and 2750 models are used for the transfer of
calibrated profile data for external profile analysis, for example in a PC.
The sensor can be configured via a FireWire or Ethernet interface. The
profile information is also transferred via this same interface. Details of
the software interface can be found in the „Integrating scanCONTROL in
application software“ chapter.
The programmable RS422 port can be used as a trigger or encoder input.
scanCONTROL 2700-25
scanCONTROL 2750-25
scanCONTROL 2700-50
scanCONTROL 2750-50
scanCONTROL 2700-100
scanCONTROL 2750-100
Scope of delivery:
Sensor, power supply cable 4.5m, RS422 connector,
Demo-CD, SDK, sensor protocol
Profile transfer
scanCONTROL 2700: 64,000 measuring points per second
scanCONTROL 2750: 1,280,000 measuring points per second
Power supply
FireWire
Ethernet
Trigger
Encoder
SMART: Profile analysis
The SMART series scanCONTROL 2710 offers a Plug & Play solution
within the integrated controller for simple measurement tasks such as
step, angle, seam and groove inspection.
The sensor is programmed via a PC using the scanCONTROL Configuration Tools. This setup is stored inside the integrated controller. The sensor
can run in the standalone mode without a PC. In addition to the measurement output via RS422, switch outputs and analogue measuring values
are available via the external output unit. The RS422 can be programmed
as a serial interface (measurement value output) or as a trigger input.
Power supply
scanCONTROL 2710-25
scanCONTROL 2710-50
scanCONTROL 2710-100
Scope of delivery:
Sensor, power supply cable 4.5m, RS422 connector,
sensor protocol, software Configuration Tools
Setup
Output Unit
IEEE 1394
PHY
ISO
ASYN
C
B
D
24V 0V
I/O
01 02 03 04
Trigger
RS422
13
01 02
A
13 14
14
A
A
C
B
D
+
Ñ
C
B
D
13 14
C
B
D
+
+
+
+
- -
-
-
-
-
+
-
15 16
S
750-531
750-550
750-626
A
C
B
D
A1 A2
+ +
PE PE
Analogue measurement values
13 14
A
M M
Digital output
S
750-600
Measurement values
5.6±1
A
34
30
C
max. ø10
10
max. ø18
1
34.5
29
ø 17.9
109.5
73.2
12
20.5
0
scanCONTROL 2700-25 / 2750-25 / 2710-25
0
0
69
68
73
63
0
53.3
18
13
5
0
84.4
R 20
ø8
13
13
0
0
81
65
20.5
34.5
extended
measuring range
22
sensor field of view
85
90
115
125
85
90
Standard
measuring range
Extended
measuring range
102.5
115
125
23
25
27
extended measuring range
29
laser line
20°
0
18
13
127
R1
0
117
B
106
84
64
0
5.5
4x thread M4 for protection cover plate
mounting; not intended for sensor mounting
29
30
34.5
34
Three mounting holes M4x5
on each side A, B, C
63
ø5.5
73
12
0
12
13
Model
Compact
Highspeed
SMART
2700-25
2750-25
2710-25
scanCONTROL
Start of measuring range
z-axis (height)
Standard measuring range
25mm
Extended measuring range
40mm
Linearity
1)
x-axis (width)
102.5mm
End of measuring range
115mm
Start of measuring range
85mm
End of measuring range
125mm
±0.2% FSO (3sigma)
±50μm
Resolution
Reference resolution
90mm
Midrange
0.04% FSO
10µm
Start of measuring range
23mm
4µm
2) 3)
Standard measuring range
Extended measuring range
Midrange
25mm
End of measuring range
27mm
Start of measuring range
22mm
End of measuring range
29mm
Point distance
Midrange
40µm
Resolution x-axis
640 points/profile
Profile frequency
Measurement rate
100Hz
2,000Hz
100Hz
64,000 points/sec
1,28 mio points/sec
-
FireWire



Ethernet



RS422 4)



Trigger
4)



Counter (encoder) 4)


Interfaces profile data
Signal output SMART
RS422 4)

Analogue 5)

Switching signal

5)
Display (LED)
1x laser, 1x power/error/status
Protection class
IP 64
Operating temperature
0°C up to 50°C
Storage temperature
-20°C up to 70°C
up to 20m
Cable length
Ethernet with Switch
FireWire with HUB
Weight
up to 50m
appr. 700g
Only at RS422, no isolation of 24V-supply, internal circuit and FireWire bus.
If isolation necessary, external 24V-DC-DC-converter required
Galvanic isolation
Vibration
2g / 20 ... 500Hz
Shock
15g / 6ms
Supply
8-30 VDC, 500mA
Light source
semiconductor laser 658nm
Aperture angle laser line
Laser power
20°
standard
10mW (class 2M)
optional
20mW (class 3B)
Laser off
Permissible ambient light (fluorescent light) 2)
Standard measuring range
2)
Measuring object: Micro-Epsilon standard object (metallic, diffusely reflecting material)
3)
According to a one-time averaging across the measuring field (640 points)
4)
Programmable as serial interface or synchronisation input or encoder input
5)
Only with Output Unit
FSO = Full scale output
1)
via software (standard) / via external contact (optional)
10,000lx
5.6 ±1
A
34
30
C
max. ø10
max. ø18
10
0
1
34.5
29
0
ø 17.9
124.5
93.3
21
12
0
scanCONTROL 2700-50 / 2750-50 / 2710-50
69
68
12
0
18
13
63
73
29
34.5
R10
130
B
121.2
99.2
77
0
5.5
4x thread M4 for protection cover plate
mounting; not intended for sensor mounting
30
34
Three mounting holes M4x5
on each side A, B, C
142
5.5
73
63
64.9
0
18
13
5
0
105
R20
ø8
13
13
0
0
102
85
21
34.5
0
14
laser line
20°
extended
measuring range
41
sensor field of view
160
160
175
175
200
225
Standard
measuring range
Extended
measuring range
225
260
260
44
50
56
extended measuring range
64
15
Model
z-axis (height)
Smart
2750-50
2710-50
175mm
Midrange
200mm
Extended measuring range
100mm
1)
End of measuring range
225mm
Start of measuring range
160mm
End of measuring range
260mm
±0.2% FSO (3sigma)
±100μm
Resolution
Reference resolution
x-axis (width)
Highspeed
2700-50
Start of measuring range
Standard measuring range
50mm
Linearity
Compact
scanCONTROL
0.04% FSO
20µm
Start of measuring range
44mm
10µm
2) 3)
Standard measuring range
Extended measuring range
Midrange
50mm
End of measuring range
56mm
Start of measuring range
41mm
End of measuring range
64mm
Point distance
Midrange
80µm
Resolution x-axis
640 points/profile
Profile frequency
Measurement rate
100Hz
2,000Hz
100Hz
64,000 points/sec
1,28 mio points/sec
-
FireWire



Ethernet



RS422 4)



Trigger
4)



Counter (encoder) 4)


Interfaces profile data
Signal output SMART
RS422 4)

Analogue 5)

Switching signal

5)
Display (LED)
1x laser, 1x power/error/status
Protection class
IP 64
Operating temperature
0°C up to 50°C
Storage temperature
-20°C up to 70°C
up to 20m
Cable length
Ethernet with Switch
FireWire with HUB
Weight
up to 50m
appr. 800g
Only at RS422, no isolation of 24V-supply, internal circuit and FireWire bus.
If isolation necessary, external 24V-DC-DC-converter required
Galvanic isolation
Vibration
2g / 20 ... 500Hz
Shock
15g / 6ms
Supply
8-30 VDC, 500mA
Light source
semiconductor laser 658nm
Aperture angle laser line
Laser power
20°
standard
10mW (class 2M)
optional
20mW (class 3B)
Laser off
Permissible ambient light (fluorescent light) 2)
Standard measuring range
Measuring object: Micro-Epsilon standard object (metallic, diffusely reflecting material)
According to a one-time averaging across the measuring field (640 points)
4)
Programmable as serial interface or synchronisation input or encoder input
5)
Only with Output Unit
FSO = Full scale output
1)
2)
3)
via software (standard) / via external contact (optional)
10,000lx
A
34
30
C
max. ø10
10
max. ø18
1
5.6±1
34.5
29
ø17,9
152.5
125.3
20.5
12
0
scanCONTROL 2700-100 / 2750-100 / 2710-100
0
0
69
68
12
0
82
18
13
5
0
137.4
R 20
ø8
13
0
13
0
134
117
20.5
34,5
sensor field of view
laser line
20°
300
Standard
measuring range
Extended
measuring range
extended
measuring range
76
300
350
350
400
450
450
88
100
112
extended measuring range 148
600
600
0
18
13
29
34.5
63
30
34
Three mounting holes M4x5
on each side A, B, C
R 1 160
0
170
73
63
B
149.2
127.2
77
0
5.5
4x thread M4 for protection cover plate
mounting; not intended for sensor mounting
73
ø5.5
0
16
17
Model
scanCONTROL
z-axis (height)
Linearity
1)
x-axis (width)
SMART
2750-100
2710-100
350mm
Midrange
400mm
End of measuring range
450mm
Start of measuring range
300mm
End of measuring range
600mm
±0.2% FSO (3sigma)
±200μm
Resolution
Reference resolution
Highspeed
2700-100
Start of measuring range
Standard measuring range
100mm
Extended measuring range
300mm
Compact
0.04% FSO
40µm
Start of measuring range
88mm
Midrange
100mm
End of measuring range
112mm
15µm
2) 3)
Standard measuring range
Extended measuring range
Start of measuring range
76mm
End of measuring range
148mm
Point distance
Midrange
160µm
Resolution x-axis
640 points/profile
Profile frequency
Measurement rate
Interfaces profile data
100Hz
2,000Hz
64,000 points/sec
1,28 mio points/sec
-
FireWire



Ethernet



RS422 4)




Trigger
4)


Counter (encoder) 4)


Signal output SMART
100Hz
RS422 4)

Analogue 5)

Switching signal 5)
Display (LED)

1x laser, 1x power/error/status
Protection class
IP 64
Operating temperature
0°C up to 50°C
Storage temperature
-20°C up to 70°C
up to 20m
Cable length
Ethernet with Switch
FireWire with HUB
Weight
up to 50m
appr. 850g
Only at RS422, no isolation of 24V-supply, internal circuit and FireWire bus.
If isolation necessary, external 24V-DC-DC-converter required
Galvanic isolation
Vibration
2g / 20 ... 500Hz
Shock
15g / 6ms
Supply
8-30 VDC, 500mA
Light source
semiconductor laser 658nm
Aperture angle laser line
Laser power
20°
standard
10mW (class 2M)
optional
20mW (class 3B)
Laser off
Permissible ambient light (fluorescent light) 2)
Standard measuring range
2)
Measuring object: Micro-Epsilon standard object (metallic, diffusely reflecting material)
3)
According to a one-time averaging across the measuring field (640 points)
4)
Programmable as serial interface or synchronisation input or encoder input
5)
Only with Output Unit
FSO = Full scale output
1)
via software (standard) / via external contact (optional)
10,000lx