Split FTV Series
Transcription
Split FTV Series
PLXRVN1601 Wall Mounted Series COOLING ONLY [50Hz] 220-240V “R32, The Environment Friendly Refrigerant” What Is R32 Refrigerant? Advantages Of R32 Refrigerant “ZERO” Ozone Layer Depletion Easy To Recycle & Reuse Lower Global Warming Impact Higher Energy Efficiency R32 refrigerant is a solution to tackle global warming with h higher efficiency and perfomance. R32 refrigerant has the ffavorable global warming potential (GWP) and reduce in ccharge amount. With this, CO2 emission can be reduced by 7 75%. Lower Global Warming Potential (GWP) R32 has lower global warming impact with ZERO ozone layer depletion. 1 Less Refrigerant Charge Amount R32 is also lower in density which means less refrigerant charge amount is used. x al es according acco accordi cordin ording rding diing ngg too Intergovermental In Interg Intergove Intergover Intergo Inter Intergovermental Intergov t rgovermental tergovermental gover vermental eer ermental rmental mental t l Panel P l On O Climate Cli t Change C Ch (IPCC) (IPCC (IPCC) (IPC C) 4th 4 * GWP values assessment report. Higher Efficiency, Better Performance R32 has higher energy efficiency as a result of lower fluid resistance. R32 has better performance due to better heat transfer over R22 and R410A. HIGHER COST EFFICIENCY SAVING 2 Features Stylish Panel Ideal blend of style and function. Easier cleaning by just wiping the panel. This ensures the air-conditioner looks brand new at all time. Sleep Mode Compact & Easy-to-Use Handset Once activated, sleep mode ensures a comfortable environment for restful sleep. The set temperature will increase gradually according to normal sleeping temperature patterns. • • • Prominent 40mm LCD display. Real time clock display. Dedicated buttons for Quiet and Turbo functions. ling 1 2 Cooling mode rs 0 Sleep 1/2 Set O n +1˚C +0.5˚C +0.5˚C Hou Temperature Coo Turbo Mode Lower Sound Level Once turbo function is activated, the air-conditioner will run at MAX speed for 20 minutes. This enables the set temperature to be achieved faster. With up to five selectable fan speeds, users are given more choices. By selecting Quiet mode, the sound pressure level can be reduced down to an unobtrusive 25 dBA. T room T set Start 20min 25 30min dBA If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared. Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout. Power Failure Op era tion Power Returns Re Sto p E P2 R OM Setting stored before power failure 3 sta rt Indoor Air Quality (IAQ) Protection Titanium Apatite Filter Micron-scale fibers trap dust while titanium apatite absorbs organic contaminants such as bacteria and viruses. In addition, the titanium oxide is activated by natural light, allowing it to break down and eliminate odours. The filter effectively deactivates bacteria and viruses. It lasts for three years without replacement if washed about once every six months. Titanium Oxide • Photocatalytic deodorizing filter • Mechanism of photocatalyst: - Titanium Oxide is activated by exposure to light. - Becomes highly oxidative. - Dissolves absorbed substances into harmless water (H2O) and carbonn dioxide di (CO2). Step 1 • Absorption of dangerous airbone particles like dust, pollen and cigarette smoke. • Dissolves odour, bacteria and virus. Step 2 Step 3 Natural Sunlight When photocatalyst is exposed to light, it is activated and absorbs odour particles A chemical reaction decomposes the odours into CO2 and H2O The odourless substance is then released into the air. Absorption power is more than doubled, dissolution force is increased. Decomposed Deac vated Ac ve Airborne Virus Power to absorb bacteria and viruses more than DOUBLED! Dissolu on efficiency is also improved This product is not a medical device, medical treatment device or therapeuƟc goods. This product is not intended to have any therapeuƟc use or to be used for the diagnosis, treatment relief or prevenƟon of illness. If you have a health concern or are not feeling well, please consult a health care professional. 4 Microchannel Heat Exchanger (MCHX) Microchannel coil is constructed utilizing all-aluminium brazed fin which is metallurgically bonded to a series of multiple parallel flow microchannels that have been optimized to increase heat transfer. Improved Heat Transfer Performance Improved Durability Refrigerant side heat transfer tra is maximized Dummy tube placed on top via multiple tiny refrigerant refrigera channels which and nd bottom to protect the provide increased in primary prim surface first rst and the last functional pressure drop without excessive press tube ube Air side heat transfer is maximized by the insertion of angled and louvered fins in between the flat tubes Improved coil design that is The he brazed bond between the not as susceptible to fin fin and tube further maximizes damage compared to conductive heat transfer conventional fin design The heat transter performance can reach 10 - 30% more than standard copper tube coil that allow comparable performance to be achieved with a smaller coil microchannel coil design. Microchannel Coil Construction Improved Corrosion Resistance The use of two dissimilar materials in Cu-Al coil are exposed to premature corrosion by their nature due to the galvanic couple inherent. Comparatively, the mono-metal Aluminium MCHX coil minimizing the possibility of galvanic corrosion. The Salt Spray Test below indicates that both Hydrophilic Coated Cu-Al coil and zinc enriched Microchannel coil exceeds the minimum test duration criteria, hence maximizing system reliability. Testing Condition Copper-Aluminium Coil with Hydrophilic Coating Microchannel Coil Fins still have full contact with copper tubes Fins still have full contact with microchannel tubes Salt Type : Sodium Chloride (JIS K8150) Salt Concentra : 50 + 5g/L pH Range : 6.2 - 7.2 Temperature : 35 C o Water : Distrill water not more than 22us/cm in electric o o conductivity 25 C + 2 C Salt Test Duration : 1000hr Reduced d Refrigerant Refri R efrig efrige ffrige riger rige rigera igerant igeran erant rant ant ntt Charge C Cha Char Ch harge harge rge Due to its effective design, microchannel coil can be built with smaller volume, thus lowering the refrigerant charge by more than 30%, subjected to model specification. Lower Weight In addition, microchannel coil offers a weight advantage over copper tube. This translates into unit weight reduction which eases unit installation. 5 Wall Mounted (50Hz) * MCHX GOLD * OpƟonal FTV25/35/50/60BXV1V RV50/60BXV1V RV25/35BXV1V › › › › › Uniform air distribution Quiet operation Easy maintenance Stylish panel Turbo mode › › › › › With Titanium Apatite filter Low sound level Wireless handset BRC52A62 (C/O) is supplied as standard Anti corrosion hydrophilic gold fin heat exchanger (RV25BXV1V) Microchannel coil heat exchanger (RV35/50/60BXV1V) Specification for Wall Mounted - Cooling only (R32) FTV25BXV1V FTV35BXV1V FTV50BXV1V FTV60BXV1V RV25BXV1V RV35BXV1V RV50BXV1V RV60BXV1V Btu/h kW W/W 9300 2.73 3.01 3 Star 12000 3.52 3.01 3 Star 18500 5.42 3.00 3 Star 21300 6.24 2.92 3 Star V/Ph/Hz CFM dBA mm mm mm kg 220-240/1/50 358/342/282/225/209 39/37/33/27/25 288 859 209 9 220-240/1/50 372/355/298/242/225 40/39/35/29/28 288 859 209 9 220-240/1/50 594/531/474/422/381 44/42/39/36/35 310 1124 237 14 220-240/1/50 641/614/537/474/418 48/46/43/39/37 310 1124 237 14 Indoor Model Name Outdoor Model Name Nominal Cooling Capacity Indoor Nominal EER Star Level Power Supply Air Flow Sound Pressure Level Height Width Depth Net Weight Gross Weight kg 10.5 10.5 15.5 15.5 V/Ph/Hz dBA mm mm 220-240/1/50 48 550 658 220-240/1/50 48 550 658 220-240/1/50 51 651 855 220-240/1/50 52 651 855 Depth Net Weight mm kg 273 28 273 28 328 41 328 41 Gross Weight Pipe Connection - Liquid Pipe Connection - Gas kg mm mm 30 6.35 9.52 30 6.35 9.52 44 6.35 12.70 44 6.35 12.70 m m 25 15 25 15 30 15 30 15 Outdoor Power Supply Sound Pressure Level Height Width Max. Piping Length Max. Elevation 6 Icon Features COMFORT Turbo Mode - Rapid cooling/hea ng with highest fan speed for immediate comfort FIN TYPE AL Bare Aluminium Fin Quiet Mode - Effec ve cooling with lower noise level GOLD An Corrosion Hydrophilic Gold Fin Dry Mode - Keeping the room dehumidified, while maintaining room temperature MCHX Microchannel Heat Exchanger Auto Mode - Auto switching between cooling and hea ng mode depending on room and set temperature Sleep Mode AIR FLOW CONTROLLER Selectable Fan Speed - Different fan speed is available for comfort selec on With wireless remote controller Belt Driven Evaporator Motor With wired remote controller Variable Pitch Pully Drive Package Automa c Ver cal Swing - Automa c movement of air discharge louver for uniform air distribu on Manual Horizontal Air Flow - Adjustable horizontal discharge grille for desired air flow direc on 4 Way Air Discharge POWER SUPPLY IAQ Washable Saranet Filter - Removal of airborne dust par cles through saranet filter ensures cleaner air supply Power from Indoor Titanium Apa te Photocataly c Air-Purifying Filter Power from Outdoor Bio An body Filter Ionizer Note: Dealer Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia www.daikinmalaysia.com Head office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan. Specifications, designs and other content appearing in this brochure are current as of December 2015 but subject to change without . notice c All rights reserved