HTR-202 - QuickMedical

Transcription

HTR-202 - QuickMedical
Befour, Inc.
102 Progress Drive
Saukville, WI 53080
Phone: 262-284-5150
Toll Free: 1-800-367-7109
Fax: 262-284-5966
Email: [email protected]
www.befour.com
HTR-202
Portable
Digital Height Rod
©2014 Befour, Inc.
Rev.1
INSTRUCTION MANUAL
Warranty Service
Table of Contents
Introduction .............................................................................................
3
Cautions & Warnings ..............................................................................
4
Assembly Instructions
Before Assembly .................................................................................
Headpiece Battery Insertion & Display Format .……...……...……...…
Assemble the Height Rod …………………………………………….…..
Mounting the HTR-202 to the Door ……………………………..……….
HTR-202 images……...…………………………………………………….
5
6
7
8
9
Call (800) 367-7109 to obtain a Return Authorization number (RA#) for
warranty service. Then, send the product with freight and insurance to:
Befour, Inc.
RA# _______________
102 Progress Drive
Saukville, WI 53080
Make certain your height rod is properly packaged to avoid damage in transit
to the factory. If your height rod is not covered by warranty, or has been
damaged, an estimate of repair or replacement costs will be provided to you
for approval prior to servicing or replacing.
Serial Number
Operation Instructions
Calibration……………...........................................................................
.
Measuring Height ………………………………………………………….
10
13
Your model and serial identification numbers are located on the back of the
measurement rail and on the inside of the battery cover. Take the time to
record the serial number for future reference when communicating with the
Befour service department.
Care and Maintenance
Cleaning ..............................................................................................
Troubleshooting and Frequently Asked Questions …..........................
15
16
Model Number
HTR-202
Serial Number
___________________
Specifications
Befour Model HTR-202 Specifications ................................................
17
Warranty
Befour Model HTR-202 Warranty .........................................................
How to Obtain Warranty Service .........................................................
Serial Number ……………………………………………………………..
2
18
19
19
Date Purchased ___________________
19
WARRANTY
Befour Model HTR-202 Warranty
This electronic height rod has been inspected and tested in accordance with
rigid quality specifications at Befour, Inc. As a result, Befour, Inc. warrants
for a period of three (3) years from the date of purchase that this product is
free from defects in material and workmanship. Warranty excludes
batteries.
Befour’s obligation under this warranty is limited to the repair and/or
replacement of defective parts or (at the discretion of Befour) the complete
replacement of the height rod or a related component.
This warranty does not apply to a product that has been altered, subject to
apparent misuse, abuse, accidents, unauthorized repair, or operated other
than in accordance with the instructions herein. Befour, Inc. must be notified
promptly and within the warranty period of the existence of a defect. Befour
shall have the sole right to determine whether a defect exists.
Introduction
This Befour, Inc. HTR-202 digital height rod (stadiometer) is a precision
instrument designed to provide accurate, reliable, and repeatable
measurements. In addition, it incorporates many unique features making
the height measurement process simple, fast, and convenient.
This operations manual contains instructions for installation and use of this
HTR-202. In order to achieve optimal results, the operator must read this
manual thoroughly before using this instrument.
If any questions arise regarding this height rod or its use, please contact
Befour, Inc. at 800-367-7109.
If a product is to be returned to the factory for repair, call for a Return
Authorization number (RA#). Products returned without an RA# will be
refused. Purchaser must pay freight charges on a height rod authorized for
return.
If the product is within the warranty period and the defect is in material or
workmanship, the product will be repaired or replaced and shipped back at
no charge.
If the product is out of warranty or some other defect exists due to misuse,
etc, Befour will call with an estimate for repair and return freight.
This warranty is the exclusive obligation of Befour, and the exclusive remedy
of the purchaser regarding defects in the product. Befour, Inc. makes no
other warranties expressed or implied. No person is authorized to modify in
any manner Befour’s obligation as described above. In the event of
questions related to this warranty, to report defects, or to request an
authorization for return, please contact the Befour, Inc. customer service
department at 800-367-7109.
18
3
SPECIFICATIONS
Cautions & Warnings
Befour Model HTR-202 Specifications
Failure to comply with the following may void the warranty on the digital
height rod.

To ensure proper operation of the Model HTR-202, this operator’s
manual should be reviewed carefully before operation. Keep this
manual available for future reference and also for use in the orientation
of new personnel.

If the height rod becomes damaged, it should not be used until properly
serviced. All repairs should only be performed by Befour, Inc.

Locate the height rod so it is out of the way of normal foot traffic.

When not in use, position the headpiece slide above head height to
minimize accidentally walking into the head-piece.

Do not force the head-piece slide past its upper and lower stops.

Always move the head-piece slide only by the headpiece knob.

Do not use abrasive cleaners on the height rod.
DIMENSIONS
Height
Width
Depth from wall
Measurement Rail Only
Headpiece on Rail
Weight
0.5 inches (1.3 cm)
8 inches (20 cm)
2.5 lbs. ( 1.1 kg)
POWER REQUIREMENTS
Batteries
Battery Life
(2) aaa alkaline (included)
Approx. 10,000 measurements
OPERATING CONDITIONS
Temperature
Humidity
Normal Room Temperature
Normal Room Humidity
PERFORMANCE
Measurement Span
Accuracy
Maximum Rate of Motion
4
57.5 inches (146 cm)
2.2 inches (5.6 cm)
51 inches (130 cm)
+/-0.1 inch (+/- 0.1 cm)
60 inches per second (152 cm)
17
ASSEMBLY INSTRUCTIONS
Troubleshooting / FAQ’s
Headpiece only displays “Strt”.
The headpiece must travel past the reference dot after it is turned on to
display a numeric value.
The display does not change while the headpiece is being raised.
The measurement value only changes while the headpiece is moving
downwards. This is an intentional design feature that is part of the autohold function. Once the measurement is taken, the headpiece can be
raised out of way so the subject can move away from the height rod and
the measurement value is retained.
If I don’t like the measurement, can I quickly re-measure?
Sure, while the subject is still under the headpiece, simply raise the
headpiece a little ways and then lower to take a second measurement.
Before Assembly
Carefully inspect the carton for shipping damage before unpacking. If
significant damage is found, keep all packaging and contact your shipper or
Befour immediately. Claims must be filed with the shipper as soon as
possible after receipt of damaged goods.
Carefully unpack the components from the shipping container. Your
height rod contains the following items:







Calibration rod
Rail assembly
Headpiece with digital readout
(1) lower end cap with two mounting screws
(2) “aaa” alkaline batteries
(1) Door mount bracket
(2) Rubber feet
Bracket knob
connector
Is there a quick way to do a calibration check?
Yes, once calibrated, the value when the headpiece is all the way down
(against the lower endcap) is a constant. You can record this value and
quickly check whenever desired.
Top mounting hole
in upper endcap
(BEFOUR label)
Knob
Why does the height rod display 5’ 7.3” as 5. 7.3?
This is a limitation of the bright LED digits. We have found people become
accustomed to this format very quickly.
Battery
holder
Reference
dot
Rail
Portable
mounting
bracket
Adjustable
door clamp
Display
On/off
button
16
Calibration
rod
5
Bottom rail
rubber feet
CARE AND MAINTENANCE
Headpiece Battery Insertion & Display Format
At the same time the batteries are inserted, you may also select the desired
display unit of measure format.
1. Open the battery cover on the top of the headpiece.
2. Insert the (2) aaa batteries, leaving one end up as shown below.
3. Press the on/off button. While continuing to hold the on/off button down,
insert the battery fully in to the headpiece.
4. After 3 seconds, “InIt” will display. Thereafter, the display will continue to
sequence through your three display options while you hold down the
button:
Inch
nnnn
Feet
(inch display)
(i.e. 79.3)
(centimeter display)
(i.e. 201.4)
(feet & inch display)
(i.e. 6. 7.3)
Cleaning Procedures
Proper care and cleaning of the HTR-202 is essential to ensure a long life of
accurate and effective operation.
All external surfaces can be wiped clean with a damp cloth or tissue. A mild
soap and water solution may be used as well. Wipe unit dry with a clean,
soft towel.

DO NOT immerse any part into cleaning or other liquid solution.

DO NOT use isopropyl alcohol or other such solutions to clean the
headpiece.

DO NOT use abrasive cleaners.
5. To select your format, release button when the desired format appears.
6. Replace the battery cover.
Note: Display format selection can also be made any time after the height
rod is mounted.
6
15
Assemble the Height Rod
3. Have the patient stand under the
headpiece.
Position the rail, the headpiece, and
the lower end cap. The lower end cap
will arrive with two small black phillips
screws partially tightened in the end
cap.
Lower the headpiece so it just
touches the crown of the head.
To re-measure, raise and then
lower the headpiece.
screws
When measurement is complete,
raise the headpiece and have the
patient walk away. Value will
remain locked on the display for
30 seconds. Push on/off button to
turn off. Display will turn off
automatically after 30 seconds of
non-activity.
Slide the headpiece into the dovetail
grooves in the rail.
Make sure headpiece is stored
near top position.
!
NOTICE
The height measurement value displayed does not change while the
headpiece is being raised.
For safety, leave the headpiece in the top position when unit is not in
use.
Slide the lower end cap into the rail
grooves and secure by screwing in the
(2) small black phillips screws. Do not
over tighten.
Keep magnets away from height rod.
You may change the display format at any time by repeating the steps
outlined on page 6.
14
7
Mounting the HTR-202 Portable Height Rod
The HTR-202 has a 51” measurement span. The actual measurement range
will vary slightly from set-up to set-up as each door’s top mounting surface is
at a different height.
Measuring Height
1. Press and release the on/off button.
“Strt” will be flashing.
1. Determine the location for the height rod. The ideal location will have
sufficient space on the right side for the health care professional to stand
as the display is on that side. It should also have a level, hard flooring
surface — carpeted flooring should be avoided, if possible. Also, the
location should be away from foot traffic to minimize the chance of a
person accidentally walking into the head-piece.
2. Using the bracket knob, attach the mounting bracket to the top of the
height rod. Check that the bracket is straight with the height rod rail and
then tighten the knob screw. Now attach rubber feet to the bottom of the
height rod rail.
3. Set mounting bracket on top of door and tighten the adjustable door
clamp if needed.
Reference
dot
2. Move the headpiece so it passes
the reference dot. “Strt” will stop
flashing and a beep will sound.
Raise the headpiece so it will be
well above the patient’s head.
8
13
HTR-202 Portable Digital Height Rod
5. Raise the headpiece until it passes the reference dot and the “100.0” stops
flashing.
Bracket knob
Calibration is now complete. Your height rod is ready to use.
Adjustable door
clamp
HTR-202
Mounting Bracket
reference dot
HTR-202 rubber feet on
bottom of rail
NOTE: You may change the display format at any time by repeating the steps
outlined on page 6.
HTR-202 Sliding head piece
12
9
Calibration
Calibration needs to be done with door mounting. Each time the
measurement rail is moved from one door to a different door location, it will
need to be re-calibrated. The height rod retains calibration during battery
changes.
4. Lower the headpiece until its bottom silver surface just touches the top of
the calibration rod. While holding the headpiece touching the calibration
rod, press and release the on/off button. “100.0” will now be flashing on the
display.
Use care and recheck your work as calibration is the key factor in the
accuracy of the height rod.
1. Turn on by pressing and releasing the on/off button. A flashing “Strt” will
display.
2. Press and hold the on/off button for 7 seconds until flashing “r100”
displays. Release the button.
calibration
rod
3. Position calibration rod under stadiometer and slide head piece down until
lower surface contacts calibration rod.
10
11