Ag Leader ParaDyme v3.8.30475 Firmware Release Notes
Transcription
Ag Leader ParaDyme v3.8.30475 Firmware Release Notes
Ag Leader ParaDyme v3.8.30475 Firmware Release Notes Ag Leader is pleased to announce the release of new ParaDyme firmware. Features and improvements in this version are listed below. This ParaDyme version requires the system be on 3.0.25494 or higher firmware. If on older firmware the system needs to be upgraded to version 3.0.25494 prior to upgrading to version 3.8.30475. Contact Ag Leader customer support for version 3.0.25494. ParaDyme upgrades must be performed within 5 minutes of powering the system up; If the system was previously powered, power-cycle the system prior to performing the upgrade. ParaDyme System Enhancement: The following items have been added with version 3.8.30475 release: Prepared: GNSS Leap second in June 2015 Fixed: Miller 5000 Series WAS ground fault Fixed: No WAS calibration failures for combines Fixed: Curvature display in Steering Components screen for applicable platforms Fixed: JD ISO error when coming to a stop while engaged Fixed: MT9xxC disengage messages during field operation Fixed: Displays correct “Authorization Failed” message if NTRIP client reports a username or password as not valid Fixed: Factory remote engage switch on MT7xx series vehicles Fixed: WAS calibration failure during auto-calibration related to valve polarity Fixed: AGCO CAN profiles successfully load after system power cycle Enhanced: ECU4 firmware upgrade for new profiles Enhanced: Displays base satellites including GLONASS satellites when system is not GLONASS unlocked Enhanced: Low Speed operation on JD ISO 4WD and Versatile 4WD vehicles New Vehicle Kit Support: Versatile 260/290/310 MFWD with Steer Ready Option Versatile 4WD and Delta Track 350/375/400/450/500/550 with Steer Ready Option RoGator RG 700/900B/1100B/1300B CAN Steer Ready TerraGator TG 7300B/8300B/9300B CAN Steer Ready John Deere Sprayer R4030/R4038/R4045 AutoTrac Ready Gleaner Super 8 Combine S68/S78/S88 AutoGuide Ready Case Titan Floater 4030/4530 AccuGuide Ready Case Patriot Sprayer 3240/3340/4440 AccuGuide Ready Case Magnum Tier 4b 180/200/220/240/250/280/310/340/380 AccuGuide Ready New Holland T8 Tier 4b T8.320/T8.350/T8.380/T8.410/T8.435 IntelliSteer Ready Case Steiger 4WD/QuadTrac/RowTrac 370/420/470/500/540/580/620 AccuGuide Ready New Holland T9 4WD/SmartTrax T9.435/T9.480/T9.530/T9.565/T9.600/T9.645/T9.700 AccuGuide Ready NOTE: Current Preferred Roaming List (PRL) for North America 20119 – Verizon Prioritized 10933 – Verizon Only 24091 – 850 MHz 40112 – Sprint Prioritized 20119 is the recommended PRL. After selecting this PRL, power cycle the system to accept the change. Known Limitation: ParaDyme Firmware Upgrade can take up to 15 minutes to complete Do not remove power from system during upgrade. If upgrade doesn’t complete after 30 minutes contact technical support Power Cycle after Copying System Logs The system should be power cycled after copying system logs to ensure proper GNSS startup NTRIP – use the numerical IP address for an NTRIP server – not a name Typing the name of the NTRIP server, rather than typing the IP address can cause problems. Always use the numeric IP address if available After Import or Export Vehicle, GPS may not return automatically, requiring a reboot The GeoSteer system stops tracking GPS during a vehicle import/export to speed up the operation. If the system does not return to tracking GPS, the system may need to be power cycled. After Auto-Steering reverse for a very long distance, ParaDyme performance may degrade Steering in reverse for long distances may result in degraded performance. If this occurs, drive forward for a short period of time before engaging the system. Changing RTK Connection Type Changing RTK Connection type (e.g. from NTRIP to Internal) can result in a system reset. A power cycle may be required. Changing Differential Types from SBAS to Autonomous A system reboot is required when differential type is changed between SBAS and Autonomous. Changing vehicle profiles The ParaDyme system supports multiple vehicle profiles so you can move your ParaDyme between vehicles. A reboot may be required after changing vehicles and profiles to ensure the new profile is being used correctly especially if the orientation of the GCU is different between the vehicles. Australian Cellular Services Require GPS Fix In Australia, the cellular modem will not connect to the service provider the first time unless the ParaDyme System has a valid GPS position. The cellular network uses this information to activate the cellular plan and allow communications. This only has to be performed once. Conditions Requiring a System Reboot In rare situations, the ParaDyme system may require a power cycle in order to restore operational status to the unit. If any of the following situations should occur, power-cycle the ParaDyme System before moving on to other troubleshooting options. The display freezes during the “loading” screen when attempting to enter the ParaDyme menu. Cellular communications do not work and the user finds that the cell modem has not been detected in the ParaDyme My Account tab under Details / Cell Modem. After copying system logs to ensure the GNSS engine starts up correctly. ParaDyme Steering Controller Firmware Upgrade Instructions Subject This document outlines the procedures required to upgrade the ParaDyme roof module to the latest firmware version. Refer to the firmware release notes for information on the features and enhancements that have been added with the newest release of firmware. Process Overview Procedure 1 – Download the ParaDyme Upgrade File…………………………………………………….2 Procedure 2 – Determine Roof Module Upgrade Method.....................................................................4 Procedure 3 – Navigate to the ParaDyme AutoSteer screen................................................................5 Procedure 4 – Upgrade from ParaDyme Roof Module..........................................................................7 Procedure 5 – Upgrade from Display USB Port ...................................................................................9 Note: The screen shots and steps shown in this document are provided as a general guide only. Variations from the screens shown in this document may appear, depending on your Windows version and configuration. This document assumes the user has a basic understanding of the Windows operating system. JC 7/21/14 Page 1 of 10 Procedure 1 – Download the ParaDyme Upgrade File 1. Navigate to the Ag Leader dealer site: https://dealer.agleader.com/kbp/ Procedure 1 – Download the ParaDyme Upgrade File 2. Click on “Downloads” after logging in to the dealer site. 3. Click on “Guidance and Steering” 4. Select the latest ParaDyme firmware (.tgz) file to download. If you are using Google Chrome, the file may go to a default downloads location. JC 7/21/14 Page 2 of 10 Procedure 1 – Download the ParaDyme Upgrade File continued 4.5. Using Internet Explorer, after clicking on the file to download there should be an option to open or save the .tgz file. Click the drop down menu by the save option and choose save as. This will allow you to browse the computer and save the file to the external storage device (USB drive.) 5. Find the downloads folder on your computer. Locate the ParaDyme upgrade file and right click on it to send it to the USB drive. 6. Verify that the .tgz upgrade file is on the external storage device JC 7/21/14 Page 3 of 10 Procedure 2 – Determine Roof Module Upgrade Method There are two ways to upgrade the ParaDyme roof module: 1. ParaDyme Roof Module USB Port – Attach the ParaDyme Auxiliary Harness (201-043302) to the auxiliary port on the roof module. Then plug the USB drive with the update file into the USB port on the Auxiliary Harness and then update. • Follow Procedure 3 and Procedure 4 below to complete the upgrade. 2. Display USB Port – Plug the USB drive with the update file into the USB port on the Ag Leader® Integra /Versa/Compass and then update. • Follow Procedure 3 and Procedure 5 below to complete the upgrade. Note: This option is not available for EDGE displays. JC 7/21/14 Page 4 of 10 Procedure 3 – Navigate to the AutoSteer Setup Screen The following instructions are broken into two sections, one for each of the supported Ag Leader displays. Use the appropriate section to access the ParaDyme AutoSteer screen from the display being used. Procedure 3a – EDGE display – Navigate to the AutoSteer Setup Screen 1. Power on the Edge display. At the home screen, press the wrench button. 2. From the setup screen press the GPS button. 3. Press the guidance tab. 4. Verify the guidance/steering type selection is set to ParaDyme steering. 5. Press the wrench button next to guidance/steering type to enter the ParaDyme AutoSteer screen. Continue to Procedure 4 – Upgrade from ParaDyme Roof Module. JC 7/21/14 Page 5 of 10 Procedure 3b – Ag Leader®Integra/Versa/Compass display – Navigate to the AutoSteer Setup Screen 1. Start the Ag Leader®Integra/Versa/Compass display. At the home screen, press the wrench button. 2. From the setup screen press the GPS/guidance button. 3. Verify that the guidance/steering type selection is set to ParaDyme/GeoSteer steering. 4. Press the wrench button next to the guidance/steering selection to enter the ParaDyme AutoSteer screen. Continue to Procedure 5 – Upgrade from display USB port JC 7/21/14 Page 6 of 10 Procedure 4 – Upgrade from ParaDyme Roof Module Procedure 4 – Upgrade from ParaDyme Roof Module 1. Plug the ParaDyme Auxiliary Harness (part number 2010433-02) into the auxiliary port on the roof module. Note: Verify the cables are pointed towards the center of the roof module. Attempting to plug it in the other way will cause damage to the roof module. 2. Insert the USB into the USB port of the ParaDyme auxiliary harness. 3. On the display, press the System tab from the ParaDyme Home page. JC 7/21/14 Page 7 of 10 Procedure 4 – Upgrade from ParaDyme Roof Module continued 4. Press the software upgrade button. 5. Press “from roof USB” from the list on the right. 6. Select the upgrade file from the list then press the upgrade button to start the upgrade process. Note: If there is more than one file on the USB drive, they will be displayed as well. 7. Allow the upgrade to proceed automatically. JC 7/21/14 Page 8 of 10 Procedure 4 – Upgrade from ParaDyme Roof Module continued 8. Once the upgrade has completed, press the Check button to complete the process. The ParaDyme Roof Module is now updated. 9. For best results, power down the system and restart to finalize the installation. Procedure 5 – Upgrade from Display USB Port Procedure 5 – Upgrade from Display USB Port 1. Insert the USB drive with the upgrade file into the USB port on the Ag Leader®Integra/Versa/Compass display. 2. Press the software upgrade button. 3. Press browse button to select the upgrade bundle. JC 7/21/14 Page 9 of 10 Procedure 5 – Upgrade from USB Port continued Procedure 5 – Upgrade from Display USB Port 4. Select the upgrade file from the list then press the upgrade or check button to start the upgrade process. Note: If there is more than one upgrade file on the USB drive , they will be displayed as well. 5. Allow the upgrade to proceed automatically. 6. Once the upgrade has completed, press the check button to complete the process. The ParaDyme roof module is now updated. 7. For best results, power OFF the system and restart to finalize the installation. JC 7/21/14 Page 10 of 10