REVOLUTIONARY FLOW-THRU
Transcription
REVOLUTIONARY FLOW-THRU
REVOLUTIONARY FLOW-THRU ©2014 Flexcon Industries D E S I G N G U A R A N T E E S T HE F R E S H E S T WATER QUALITY POSSIBLE. [ F L O W- T H R U , B E C A U S E M O V I N G W AT E R D O E S N ’ T S TA G N AT E ] All Flexcon Flow-Thru well tanks feature our exclusive patented Flow-Thru technology. Patented watervane flushes water through the tank eliminating the possibility of s t a g n a n t w a t e r. This assures your system will provide the freshest water quality possible ___ simply unattainable with nonFlow-Thru tanks. The Flow-Thru connection diverts system water into, and more importantly out of the tank while the Flow-Thru technology assures total recirculation o f t h e t a n k ’s water content. pump is running. This constant flushing action assures that the water in the tank remains as fresh as possible and eliminates the possibility of stagnant water during normal system operation. Flexcon Patented Flow-Thru Water Connection FT 18S includes 2 mounting feet and a stand for mounting a CPWS control box. Can be mounted in a vertical or horizontal position. 16 gauge solid steel tank, finished with highest quality urethane paint. Flexcon’s steel and new line of composite tanks incor- Flow-Thru t a n k s are also available in a light weight weather proof composite shell. porate CAD-2 our patented controlled action diaphragm. CAD-2’s steel clench ring regulates movement and prevents the diaphragm from rubbing against the tank wall. It has made Flexcon tanks the Industry leader. Flow-Thru is the ideal 100% solution for constant H i g h p r e s sure helium tested. Backed by a 5 year w a r r a n t y. installers seeking to store pressure water system water without the risk of stagnation. FT 66 FT 18 FTC 38SQ T h e R e l i a b l e S o u r c e® Standard water systems operate with a 20 PSI differential between cut-in and cut-out, the water in the tank is flushed out and replenished every pump cycle, thus greatly reducing the risk of stagnant water in the tank. 1. 2. Newer constant pressure water systems bring the pump up to speed very quickly by operating on much lower differential pressures, as little as 2-5 PSI. This means stored water is never fully exchanged, only diluted with new system water. This creates the possibility of stagnant water remaining in the pressure tank for extended periods. 3. CONSTANT PRESSURE WATER SYSTEM INSTALLATION STANDARD TANK TEE INSTALLATION PIPED THROUGH TANK INLINE INSTALLATION F L O W- T H R U TA N K S A R E AVA I L A B L E I N S T E E L , S TA I N L E S S , C O M P O S I T E DIMENSIONS & CAPACITIES, STEEL Model FT FT FT FT FT 35 35S 66 144 266 Total Tank Volume gal liters 9 32 9 32 20 80 44 170 85 325 A B C Height/Length Diameter Connection in 18.90 18.90 29.00 36.25 44.50 cm 48.10 48.10 73.66 92.07 113.03 in 12.5 12.5 16.0 21.0 26.0 cm 31.80 31.80 40.64 53.34 66.04 Total Weight 2” NPT lbs kilos 15.4 7.0 15.4 7.0 36.0 16.4 68.0 30.9 122.0 55.5 Total Weight 1” NPT 1” NPT 1 1/4” NPT 1 1/4” NPT DIMENSIONS & CAPACITIES, STAINLESS Model FT 8 FT 18 FT 18S Total Tank Volume gal liters 2.1 8 4.5 18 4.5 18 A B C Height/Length Diameter Connection in 12.0 14.5 14.5 cm 30.00 37.00 37.00 in 8 11 11 cm 20.00 28.00 28.00 1” NPT 1” NPT 1” NPT lbs 5.0 10.0 12.0 A kilos 2.3 4.6 6.9 DIMENSIONS & CAPACITIES, COMPOSITE Model FTC FTC FTC FTC 15 22 38SQ 50 Total Tank Volume gal liters 15 56.8 22 83.0 38 143.8 50 189.3 A B C Height/Length Diameter Connection in 25.60 33.10 29.75 42.90 cm 64.0 84.1 74.7 109.0 in 16.5 16.5 24.2 21.4 cm 41.9 41.9 61.5 54.4 1 1/4” sch 80 1 1/4” sch 80 1 1/4” sch 80 1 1/4” sch 80 Total Weight lbs 19.0 24.0 35.0 41.0 kilos 8.6 10.9 15.9 18.6 B C Maximum working pressure 125 psig. Maximum working temperature, internal & external 140o F. Tank pre-charge 38 psig. Q U I C K S I Z I N G C H A R T, S T E E L , S T A I N L E S S , C O M P O S I T E Model Total Tank Volume gal liters FT 8 FT 18(S) FT 35(S) FTC 15 FT 66 FTC 22 FTC 38SQ FT 144 FTC 50 FT 266 2.1 4.5 9.0 15.0 20.0 22.0 38.0 44.0 50.0 85.0 8.0 18.0 32.0 56.8 80.0 83.0 143.8 170.0 189.3 325.0 B Total Drawdown* 50 psi (.23) 60 psi (.24) gal liters gal liters .48 1.03 2.07 3.45 4.60 5.06 8.74 10.12 11.5 19.55 1.84 4.14 7.36 13.10 18.40 19.09 33.07 39.10 43.54 74.75 .50 1.08 2.16 3.60 4.80 5.28 9.12 10.56 12.00 20.40 1.92 4.32 7.68 13.63 19.20 19.92 34.51 40.80 45.43 78.00 C A *Based on precharge set at 70% of set point of constant pressure controller. Drawdown can be affected by many factors, including temperature, pressure, and elevation. > > > > w 7 3 R w w . f l 8 1 - 9 8 0 0 P o a n d o l e 6 n p x c o n i n d . c o m - 2 4 2 4 d S t r e e t h , M A 0 2 3 6 8 T h e R e l i a b l e S o u r c e®