OPERATING MANUAL PCR Pneumatically Controlled Regulator
Transcription
OPERATING MANUAL PCR Pneumatically Controlled Regulator
PCR Pneumatically Controlled Regulator OPERATING MANUAL Aviation Oxygen System Solutions by Mountain High Table of Contents PCR System Description 1 Basic PCR system operation 2 Basic PCR Components & Suggested Installation Layouts 3-5 Mechanical & Pneumatic Technical Information 6 on Congratulations on choosing the Mountain High PCR (Pneumatically Controlled Regulator) system. The PCR system is a completely integrated, pneumatic powered oxygen regulator, designed to provide you with unmatched control, safety, comfort, and convenience at an affordable price. The design intent of the PCR is to allow it to be used with any off-the-shelf CGA-540 valve cylinder, providing the ability to remove the cylinder for refilling purposes. If removing the cylinder is not convenient, a 4-sae high pressure access port ( photo B ) was provided on the back of the PCR to allow for an installation of a remote fill port and/or a remote pressure gauge, thus providing you with a variety options for your installation application needs. (see pages 3,4,5 & 6 for diagram installation suggestions). The PCR is not intended to be used as the main high pressure shut off, rather it is for giving the customer ease of use during flights and cylinder installation location options. The valve of the cylinder should be turned off during times of aircraft storage as to mitigate any oxygen system drainage. It is not necessary to close the cylinder valve during refueling, lunch stops, leg stretches, etc. The 1/8" O.D. pneumatic lines that connect the remote ON/OFF toggle switch to the PCR are flow restricted to a minute 1/64 liter-per-minute to prevent against the low pressure oxygen contributing to a shut-off event emergency. The PCR is intended to be use with any CGA-540 valve cylinder with a service pressure range of 500 psig. to 2400 psig. (nominal 1850 psig.). The functioning high pressure inlet range is 3,000 psig MAX. Operating past this inlet pressure will not cause damage, rather it may cause the PCR to be forced open, causing a "safety venting" through the low pressure outlet. The 3-way control switch option must be ordered if the PCR system will be used in a pressurized aircraft. PCR Aviation Oxygen System Description A standard PCR-4p system kit includes items the following items: L 01 02 03 04 05 06 07 08 Qty 1 1 1 1 3 4 4 1 Description PCR regulator kit with remote on/off switch & 25’ of pneumatic control lines. AL-682 cylinder. Optionally upgradeable to KF or CFF cylinders. ‘Ω’ or ‘A’ style CMK for that cylinder (your choice, ‘Ω’ style shown). 6 mm. polyurethane tubing kit. (25’). ‘T’ & ‘Y’ union kits for the 6 mm. tubing. CPC bulkhead style oxygen station outlet kits. XCP Breathing stations & tote-bags with your choice of MH3 or MH4 flowmeters. SCD and instruction inserts for all items in kit. A product of customer requests, the new PCR is a completely selfcontained remote-controlled oxygen regulator. It connects directly to any oxygen cylinder with a CGA-540 (USA) or optionally with DIN-477 (European) valve. Flow of oxygen to the user is controlled pneumatically through a set of color-coded pneumatic signal-lines that run to a panel mounted on/off switch. The PCR can be ordered in various phases from just the PCR regulator to complete PCR multi-place built-in aviation oxygen systems. Once your PCR system is plumbed, you can use any of our oxygen delivery systems including the EDS pulse-demand system and operate them at the same time others are using MH3 or MH4 flowmeters. A maximum number of six (6) slef-sealing bulkhead outlets can be mounted in many ways to suite your needs. You can add EDS stations at any time. EDS O2D2 Two-Place Pulse-Demand Oxygen unit The intended use of the PCR is for use as an aviation oxygen system where a typical cylinder pressure range would be from 500 to 2,400 psig (nominally 1850 psig). The PCR is intended to be used with any off-the-shelf CGA-540 valve cylinder at pressures up to 3,000 psig. The PCR provides a means to remotely control the low pressure outlet circuit for convenience and safety sake. The PCR regulator directly connects (by hand) to the service/refill port of any oxygen cylinder with the standard CGA-540 (USA) or optionally DIN-477 (Euro) valve allowing the cylinder to be easily removed for refilling or service. An auxiliary port on the rear side of the regulator body (not shown) is provided for an optional remote oxygen fill station and presure gauge. The PCR system is not intend to be the main turn-off for the high pressure of the cylinder used. The PCR has a minute amount of weepage under operating pressure, therefore, the main cylinder valve must be turned off during times of storage to mitigate cylinder drainage. The PCR operates by using a small fraction of the regulated out let oxygen to pneumatically operate a control valve in the PCR body. The 1/8" O.D. pneumatic lines that connect the PCR to the on/off control switch are flow restricted so that the regulated lowpressure oxygen does not contribute to any safety hazard in the event shut-off emergencies are required. In distressed situations, the amount of oxygen that may flow from a complete line cut would be about 1/64 liter per minute. This flow is many orders lower than what will be spilled from a severed 1/16" high-pressure remote gauge capillary line. Over-pressure relief of the PCR is intrinsic of its design. During times of over pressure by means of the regulator not limiting to the specified pressure, the pneumatically operated control valve then acts as a pressure relief valve where the oxygen from the cylinder will be safely vented through the over-pressure fitting outlets of the installed system. 1 Basic PCR System Operation Basic PCR system configuration Special considerations with the on/off control switch: The PCR (Pnuematically Controlled Regulator) has three (3) main parts: 1) The PCR unit with on/off control switch 2) The oxygen source (Tank / Cylinder). 3) Oxygen plumbing & outlets 1 B ON A While the switch is in the ‘ON’ position a very small fraction of oxygen pressure from the regulator is used to hold the low-pressure valve open. The control switch operates the low-pressure valve on the PCR to allow oxygen to flow to the oxygen station outlets it does not turn the high-pressure supply of oxygen on & off. It is not intend to be the main turn-off for the high pressure of the cylinder used. The PCR has a minute amount of weepage under operating pressure, therefore, the main cylinder valve must be turned off during times of storage to mitigate cylinder drainage. OFF The 3-way control switch option must be ordered if the PCR system will be used in a pressurized aircraft. 2 B A 3 1800 2200 1000 124 500 69 152 35 207 3000 PSI bar MH 3 0 0 OXYGEN SUPPLY USE NO 2 OIL Basic PCR Components & Suggested Installation Layouts Optional remote gauge & fill station kit includes: L Qty 01 1 02 1 02a 1 03 1 04 1 Description MH-300 gauge with rear-mount bezel & fitting kit (for AL & KF cylinders) 25’ coil of 1/8” OD copper line tubing kit (Standard issue) 25’ coil of 1/16” OD stainless-steel ‘capillary-line’ tubing kit. (Optional upgrade) Basic remote oxygen fill-station kit. Can be upgraded to the deluxe fill, (right). SCD and instruction inserts for all items in this kit. Optional MH-300 Remote pressure gauge ON Optional Remote Fill Stations OFF 1800 1000 2200 124 500 69 152 35 207 3000 PSI bar MH 3 0 0 OXYGEN SUPPLY USE NO OIL 1800 2200 1000 124 500 69 152 35 207 3000 PSI bar M H 3 0 0 OXYGEN SUPPLY USE NO OIL 3 Basic PCR Components & Suggested Installation Layouts ON B A The 3-way control switch option must be ordered if the PCR system will be used in a pressurized aircraft. OFF 1800 1000 2200 124 500 69 152 35 207 PSI bar 3000 MH 3 0 0 OXYGEN SUPPLY USE NO OIL 1 6 1 4 2 0 1 8 2 2 ALTITUDE 2 4 1 2 1 0 5 2 8 A34-2ip B A PILOT STATION MUST BE FREE-FLOW TYPE OUTLET ALL OTHERS MUST HAVE CHECK VALVES B A HP IN 1800 124 69 LP IN LP OUT 2200 1000 500 152 35 207 PSI bar 3000 MH 3 0 0 OXYGEN SUPPLY USE NO OIL 4 OFF Place the A34 between the outlet of the PCR and station outlets to regulate the flow to all stations with cannulas and facemasks. PILOT STATION MUST BE FREE-FLOW TYPE OUTLET ALL OTHERS MUST HAVE CHECK VALVES 2 6 X 1 0 0 0 MH The PCR regulator compliments the A34! ON B A Basic PCR Components & Suggested Installation Layouts The use of an optional pulse oximeter (see below) may be used to determine optimum settings in unique situations such as with persons who are elderly and/or are known to have respiratory issues. The PCR regulator system can be used with virtually any oxygen cylinder with a CGA-540 valve. Use the EDS O2D1 or O2D2, MH3 or MH4 with the PCR regulator system. FlightStat by NONIN CheckMate by SPO MH-3 With Oxymizer MH-4 With Facemask 5 Cannulas and Face Masks Cannula Oxymizer Cannula Standard Avator type cannulas are compatable with the MH-4 flowmwter and aare specifically selected to operate with the standard flow protocol of 1 liter per minute per 10,000 ft. to operate with the PCR system. They complement the physiological needs of a person for flight operations from sea level to the edge of class-A airspace, 18,000 ft. The Aviator cannulas are silicone molded with a 1 meter length of high quality PVC tubing and fitting. They fit to the face with a set of over-the-ear feed tubes to accommodate almost any face. Beards and mustaches will not compromise the delivery properties of cannulas in general. However, even the slightest amount of nasal congestion can. Therefore, it is advisable Standard that a face mask be used in tip the event of such problem. The Oxymizer cannula is specifically calibrated to operate with the MH-3 flowmeter and is compatable wit the PCR system. In most Flared cases the tip standardtip cannula suits the needs of most people, while the flare-tip type may be needed to fit a large person or one that has large nasal openings. Standard-tip cannulas are issued by default unless otherwise stated at time of purchase. Cannulas are a personal device and should not be shared between persons. In addition, it is the only item in the system that should be replaced frequently, because even with the best cleaning efforts, bacteria and such can contaminate cannulas and pose a health risk. Head-Set Boom Mounted Cannula Our optionally available MH E-Z-Flow Boom Cannula is a head-set mountable cannula system that can be used with the PCR system. Face masks should be on board in the event someone should develop nasal congestion where a nasal c a n n u l a would fall short in performance. Alps Face Mask (with or without microphone) Oxygen admission port with swivel quick disconnect fitting Oxygen feedtube to distributor unit Voice port or optional Microphone Ambient air admission port Expiratory valve port The Alps face mask is compatable with the MH-4 flowmeter to complement the physiological needs of a person for flight operations from sea level through pressure altitudes up to 25,000 ft. They have a four-point detachable clip system with two independently adjustable straps to accommodate almost any face. Beards and mustaches will compromise the sealing properties of face masks in general. These face masks can be cleaned with mild detergents and water. The Alps face masks have a voice-port so vocal communication is possible without mask removal. The microphone of a head-set can be placed close to the voice-port Alps and used with satisfactory results. microphone The Alps face mask can be ordered with an optional noise canceling electret-condenser microphone & cord set compatible with most com & audio systems in place of the voice port. Please specify during ordering. The Alps face mask comes in three sizes: medium, small and large. In most cases the medium and small fit most women, while the medium and large fit most men. The medium size face mask is issued by default unless otherwise stated at time of purchase. 6 7 A B C D SAE-4 AUX PORT-1 4 3 MAIN REG. FIXED PRESSURE OF 1 BAR (15 PSIG @ 20 L/MIN VALVE CLOSED MAIN VALVE D.E. N.C. PORT 'A' PORT 'B' PORT-C PORT-B AMB 3 S1 COM A 06-12-05 B PLM PORT 'A': FEED TO CONTROL SWITCH (10-32) N.C. S2 N.O. (AMB) B S4 ±0.010 ±0.005 ±0.002 ANGLES ± 0.5° FRACTIONS ± 1/64 PLM ENGINEER: 2 APPR: 05-19-04 PLM DRAWN: DATE 05-19-04 DATE ISSUED: INTERPRET GD&T PER ASME 14.5 0.X 0.XX 0.XXX (FMT REV C) 63 UNLESS OTHERWISE SPECIFIED DIMS ARE IN INCHES. TOLERANCES ARE: S3 MAIN SUPPLY TO STATIONS TO PORT-A ON PCR (RED/ORN) TO PORT-B ON PCR (YEL) SERVICE PORT TO CONTROL SWITCH (RED/ORN) 00 SIZE A DWG. #: 1 SHEET 1 OF 3 DO NOT SCALE DRAWING REV B MOUNTAIN HIGH E&S CO. REDMOND, OR. USA IN THIS DRAWING / DOCUMENT PER MH DOC: ESR-001 [ KC ] NUMBER OF KEY CHARACTERISTICS S6 ON OFF SCHEMATIC PCR THIRD ANGLE PROJECTION S5 7.65 mm (3.014) B A ADDED CORRECT PORT MARKINGS CONTROL ORIFICE WILL BE IN FITTING 1 NOTES REFLECTING SMALLER FORM-FACTOR INITIAL RELEASE REVISION HISTORY SERVICE PORT, FROM CONTROL SWITCH (YEL) FLOW CONTROL ORIFICE INTEGRATED INTO BODY OR FITTING PORT-A PLM 01-02-05 PLM E . C . O . / APPR. DATE 05-19-04 A REV 2 PORT 'B': RETURN FROM CONTROL SWITCH (10-32) PORT 'C': BSPP TO 6 MM ELBOW TUBE OUTLET FITTING OPTIONAL REMOTE GAUE & FILL STATION: AUX HP-1 (SAE-4) CGA-540 (DIN-477) MAIN INLET PORT TO CYLINDER VALVE OPEN INLET PRESSURE: 0-207 BAR (0-3000 PSIG.) OUTLET PRESSURE: 1 BAR ± .125 (~15 PSIG.) MAX. OUTLET FLOW: 50 L / MIN @ ~1 BAR PNEUMATICALLY CONTROLLED OXYGEN SUPPLY REGULATOR PCR 4 A B C D D C B A 4 P CR PNEUMATICALLY CONTROLLED OXYGEN SUPPLY REGULATOR VALVE OPEN INLET PRESSURE: 0-207 BAR (0-3000 PSIG.) OUTLET PRESSURE: 1 BAR ± .125 (~15 PSIG.) MAX. OUTLET FLOW: 50 L / MIN @ ~1 BAR SAE-4 AUX PORT-1 PORT-A AMB PORT-B OUTLET 3 3 PORT 'A' PORT 'B' PORT C B COM PORT 'C' FROM THE CONTROL SWITCH MUST BE VENTED TO AREA WHERE THE PCR RESIDES IF IT RESIDES OUTSIDE OF THE PRESURIZED CABIN N.C. N.O. 01-05-07 03-21-07 MO-DA-YR PLM PLM E . C . O. / APPR. 2 A REV A N.C. PLM 05-01-07 REVISION HISTORY C 1 NOTES N.O. 7.65 mm (3.014) COM 00 OFF MOUNTAIN HIGH E&S CO. REDMOND, OR. USA IN THIS DRAWING / DOCUMENT PER MH DOC: ESR-001 [ KC ] NUMBER OF KEY CHARACTERISTICS A DWG. #: SIZE 1 SHEET 1 OF 1 DO NOT SCALEDRAWING REV A SCHEMATIC PCR PRESSURIZED APP THIRD ANGLE PROJECTION ON INITIAL RELEASE CORRECTED CALL-OUTS FOR CONTROL SWITCH B CONTROL ORIFICE WILL BE IN FITTING PORT 'A': FEED TO CONTROL SWITCH (10-32) MAIN SUPPLY TO STATIONS PORT 'B': RETURN FROM CONTROL SWITCH (10-32) A C ORIG: 05-01-07 05-01-07 PLM DATE PLM ENG: NAME 2 APPR: DRWN: PRESSURIZED ON APPLICATIO SERVICE PORT, FROM CONTROL SWITCH (YEL) SERVICE PORT TO CONTROL SWITCH (RED/ORN) FLOW CONTROL ORIFICE INTEGRATED INTO BODY OR FITTING MAIN OUTLET BSPP TO 6 MM ELBOW TUBE OUTLET FITTING OPTIONAL REMOTE GAUE & FILL STATION: AUX HP-1 (SAE-4) N.C. D.E. MAIN VALVE MAIN SUPPLY TO STATIONS VALVE CLOSED MAIN REG. FIXED PRESSURE OF 1 BAR (15 PSIG @ 20 L/MIN CGA-540 (DIN-477) MAIN INLET PORT TO CYLINDER 4 D C B A 8 9 A B C D SAE-4 AUX PORT-1 4 CGA-540 (DIN-477) MAIN INLET PORT TO CYLINDER MAIN VALVE D.E. N.C. OUTLET PORT-B AMB PORT-A MAIN SUPPLY TO STATIONS A PORT: NC MAIN REG. FIXED PRESSURE OF 1 BAR (15 PSIG @ 20 L/MIN PCR PORT A: NC PORT B: COM 4 C PORT: NO 3 SWITCH 'A' S1 PORT B: COM SWITCH 'A' B PORT: COM 3 04-11-07 - S2 S4 04-11-07 04-11-07 MO-DA-YR PLM PLM NAME ENG: APPR: 2 04-11-07 PLM DRWN: S5 00 MOUNTAIN HIGH E&S CO. REDMOND, OR. USA IN THIS DRAWING / DOCUMENT PER MH DOC: ESR-001 [ KC ] NUMBER OF KEY CHARACTERISTICS S6 PORT C: N.O. (AMB) PORT A: N.C. OFF ON SIZE A DWG. #: 1 SHEET 1 OF 1 DO NOT SCALE DRAWING REV - SCHEMATIC FOR PCR DUAL-SEAT THIRD ANGLE PROJECTION PORT B: COM NOTES 1 PORT C: NO (AMB VENT) SWITCH 'B' SWITCH 'B' B A INITIAL RELEASE REVISIONHISTORY DUAL-SEAT APPLICATIO ON S3 PLM E . C . O . / APPR. ORIG: PORT C: N.O. PORT A: N.C. A PORT: NC B PORT: COM MO-DA-YR REV 2 A B C D 625 SE Salmon Ave. Redmond, OR. 97756-8696 U S A 800-468-8185 World Voice: 541-923-4100 World Fax: 541-923-4141 www.mhoxygen.com PCR-001-00 rev 2