test report
Transcription
test report
TEST REPORT Applicant: PKG Maxlife 136 Motu Road, Kumeu, Auckland, NZ Number: Date: HK13030903-1 8 April 2013 Sample Description Product Brand Name : AA ALKALINE BATTERIES : Maxlife / Duracell / Energizer / Eveready / E-tech / Chevron / Warrior / Dick Smith / Arlec / Zone Model No. : Maxlife – Alkaline / Energizer – Max / E-tech – Alkaline / Warrior – Alkaline / Arlec – Alkaline / : 1.5V : 9 (Nine) per brand Electrical Rating No. of Samples Duracell – Coppertop / Eveready – Gold / Chevron – Alkaline / Dick Smith – Exxtra Plus Alkaline / Zone – Alkaline Date Received Date Test Conducted : : 20 March 2013 21 March 2013 to 4 April 2013 Test Requested : IEC 60086-1: 2011 1. Clause 4.2.1 - Discharge Performance AA type battery discharge performance test for an application of Digital still camera for reference test condition Test Method : IEC 60086-1: 2011 in conjunction with IEC 60086-2 Test Results Conclusion : : See the attached sheets See the attached sheets Remark : When determining the test conclusion, the Measurement Uncertainty of test has been considered. ********************************************* End of Page *********************************************** Reviewed by : Digitally signed by Felix Kong Location: Intertek Testing Services HK Ltd. ____________________ Kong Ka Hang, Felix Assistant Manager - The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. PAGE 1 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 A COMPARISON MATRIX FOR DIFFERENT BRANDS Test result: Brand Average Discharge Duration Time (pulses) Application of Digital still camera Complied With The Acceptance Criteria Maxlife Duracell Energizer Eveready E-tech Chevron Warrior Dick Smith Arlec Zone 98 55 79 53 54 95 66 90 73 63 Yes Yes Yes No (See note 1) Yes Yes Yes Yes Yes Yes Note 1: The average is greater than the minimum average duration, however more than one battery has a service output of less than 80 % of the minimum average duration (30 pulses). Therefore the batteries are NOT complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 2 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 1. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Maxlife Datecode: 11-2019 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 106 107 97 97 88 98 97 104 88 98 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 3 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 2. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Duracell Datecode: MAR 2017 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 47 55 59 58 56 54 57 57 58 55 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 4 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 3. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Energizer Datecode: 03-2023 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 75 85 79 78 79 78 77 78 87 79 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 5 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 4. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Eveready Datecode: 03-2016 for sample number 1 - 8 & 03-2017 for sample number 9 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 69 58 58 57 26 47 66 27 74 53 Average: The average is greater than the minimum average duration, however more than one battery has a service output of less than 80 % of the minimum average duration (32 pulses). Therefore the batteries are NOT complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 6 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 5. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: E-tech Datecode: 02-2016 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 59 54 58 47 56 48 54 58 58 54 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 7 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 6. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Chevron Datecode: 01-2016 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 99 97 97 96 99 79 97 96 99 95 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 8 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 7. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Warrior Datecode: 09-2015 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 67 66 67 65 66 66 66 66 68 66 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 9 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 8. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Dick Smith Datecode: 01-2017 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 89 87 86 86 96 88 96 89 96 90 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 10 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 9. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Arlec Datecode: 06-2017 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 77 77 49 77 77 77 78 69 79 73 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 11 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Number : HK13030903-1 10. IEC 60086-1:2011 Clause 4.2.1 - Discharge performance (Digital still camera) Test Method and Acceptance criteria: LR6 (AA) discharge performance of primary batteries is specified in IEC 60086-2:2011 and is conducted in accordance with an application test, which is to simulate an application of Digital still camera. Nine samples are discharged by a 1500/650/0mW power drains load 5 minutes per hour and 24h per day, until end-point voltage reached to 1.05V. The minimum average duration (MAD) of the test is 40 pulses. Test result: Results are recorded as below. Brand: Zone Datecode: 08-2017 Sample Number Discharge Duration Time (Pulses) 1 2 3 4 5 6 7 8 9 67 66 56 55 67 65 67 64 64 63 Average: The average is greater than the minimum average duration and no more than one battery has a service output of less than 80 % of the minimum average duration. Therefore the batteries are complied with the acceptance criteria. *********************************************** End of Page ************************************************ PAGE 12 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Maxlife *********************************************** End of Page ************************************************ PAGE 13 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Duracell *********************************************** End of Page ************************************************ PAGE 14 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Energizer *********************************************** End of Page ************************************************ PAGE 15 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Eveready *********************************************** End of Page ************************************************ PAGE 16 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 E-tech *********************************************** End of Page ************************************************ PAGE 17 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Chevron *********************************************** End of Page ************************************************ PAGE 18 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Warrior *********************************************** End of Page ************************************************ PAGE 19 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Dick Smith *********************************************** End of Page ************************************************ PAGE 20 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Arlec *********************************************** End of Page ************************************************ PAGE 21 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com TEST REPORT Product Photo Number : HK13030903-1 Zone ****************************************** End of Report ******************************************* PAGE 22 OF 22 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com