TRD-2T/2TH
Transcription
TRD-2T/2TH
Sa fe t y Co n s i d e r at i o n leading to loss of life or severe injury when the indication is disregarded and wrong handling is executed. Incremental Encoder TRD-2T/2TH Totem-pole output TRD-2T□AF/BF TRD-2TH□AF/BF Output A,B,Z Main circuit Main circuit Protection circuit Do not use in a combustible or explosive atmosphere. Use only with the wiring and layout specified in the specifications. Otherwise personal injury or fire may be caused. ! Otherwise fire,electric shock,or accidents may be caused. Do not use this product for applications related to human safety. Use is assumed in an application where an accident or incorrect use will not immediately cause danger to humans. ! Otherwise electric shock or fire may be caused. Type No. Power supply 4.75~5.25V TRD―2T□A/B TRD―2T□AF/BF TRD―2T□V TRD―2T□V 1 TRD―2T□V H TRD―2TH□A/B TRD―2TH□AF/BF TRD―2TH□V TRD―2TH□V1 TRD―2TH□VH 4.75~28V Output A,B,Z 0V supply 0V A/AF: DC4.5V~13.2V Operating voltage Power Output A , B , Z 0V Do not apply any kind of stress to the wires. El e c t r i c a l s p e c i f i c at i o n s TRD-2T□V/V1/VH TRD-2TH□V/V1/VH Output A,B,Z Use only with the power supply voltage listed in the specifications. Otherwise fire,electric shock,or accidents may be caused. ! ! Wa r n i n g Line driver output Power supply 4.5~13.2V, 10.8~26.4V ! Wa r n i n g [Operating environment and conditions] Ou t p u t c i r c u i t Power supply 4.5~13.2V, 10.8~26.4V [Installation and wiring ] This symbol indicates a compulsory item or an instruction. ! Addr: No.118 Lixi Road Wuxi,Jiangsu,P.R.China Pc:214072 Tel: (0510)85167888 Fax: (0510)85161393 KEW-M8162E-E Understand the product first before use it. ! This symbol indicates a general prohibition. K OYO EL ECT RON I CS (WU X I ) CO.,LT D. TRD-2T□A /B TRD-2TH□A/B Otherwise fire or product damage may be caused. Explanation of the pictograms Thank you for purchasing series TRD-2T and TRD-2TH Incremental Encoder. Please read this Operation Manual carefully before applying this product. Use and store the equipment within the scope of the environment (vibration,impact,temperature,humidity,etc.) ,which specified in the specifications. ! This indicates contents which can cause injury or mat erial damage when the indication is disregarded or improper handling is executed. ! Ca u t i o n Operation Manual Open collector output ! Ca u t i o n This indicates contents which can cause large accidents ! Wa r n i n g R ○ [Operating environment and conditions] DC4.75V~5.25V B/BF: DC10.8V~26.4V Allowable ripple ≤3%rms Current consumption Co n n e c t i o n ≤50mA ≤80mA Signal format The shield wire(GND)is not connected to the encoder body. TRD-2T□A/B/AF/BF TRD-2 TH□A/B/AF/BF TRD-2T□V/V1/VH TRD-2TH□V/V1/VH Blue:0V Brown:Power supply Black:OUT A White:OUT B Orange:OUT Z Shield:G(ground) Ou t p u t s i g n a l t i m i n g c h a r t 200kHz Operating speed (Maximum response frequency/Pulse)×60 waveform Blue:0V Brown:Power supply Black:OUT A Purple:OUT A White:OUT B Gray:OUT B Orange:OUT Z Yellow:OUT Z Shield:GND(ground) Two-phase + home position output Max. response frequency Output Duty Ratio 50±25% Quadrature phasing 25±12.5% Home position signal width 100±50% Rising/falling time Output (CW means clockwise rotation viewed from the shaft ) TRD-2T□A/B/AF/BF TRD-2T□V/V1/VH TRD-2 TH□A/B/AF/BF TRD-2TH□V/V1/VH ≤1µs *1 ≤3µs Output configuration NPN open collector Output logic *1 - Totem-pole output - Positive logic(active high) ― current Outflow ― ≤10mA Output “H” ― voltage “L” ≥[(LPV)-3V] ≤0.4V ≤0.4V ≤DC30V ≤DC30V ― *2 ≤0.5V ― 0° -10~+70℃ Store -25~+85℃ Ambient humidity 35~85%RH(non-condensing) 20N Withstand voltage AC500V(50/60Hz)for 1 min. 5000rpm Insulation resistance Oil-resistant PVC *3 0.14mm amplitude*4 11ms with 490m/s2 Shock resistance 0° Protection construction Φ5mm Approx. 160g (with 1m cable) 2T□A/B/ AF/BF、2TH□A/B/AF/BF :5-core shielded cable(AWG26) IP50:Dust proofed *4: Durable for 1h along 3 axes *5: Applied 3 times 3 axes :8-core shielded cable(AWG26) Ca u t i o n s fo r u s e Do not wire the cable in parallel with other power lines and do not share a duct with other cables. Ex t e r n a l d i m e n s i o n s Use capacitors or surge absorption elements to remove the sparks caused by relays and 3-M3 Screw(depth7) 15 10 0° 12 12 0° TRD-2T□A/B/AF/BF TRD-2T□V/V1/VH 5 switches in the control panel as far as possible. 36 Be sure to connect all wires properly, as wrong wiring can damage the internal circuitry. Erroneous pulses may be caused at the time of power ON and power OFF. After power ON, wait Φ38 0 Φ20-0.021 0 Φ6 -0.021 for at least 0.5 sec. before use. Do not disassemble the product. As the rotary encoder is composed of precision parts, its function will be impaired when it is subjected to shocks Use sufficient care for handling and mounting. Φ3 0.2 0± Op t i o n s 7 Coupling RU-075 GJ-6 19.1 21.6 2.4 0° 12 6.9 6.9 5.2 2.8 2.8 6+0.05 36 6+0.05 12 5 9 0.5 Φ38 0 Φ20-0.021 Φ12 1. 8 6 10 ° 12 0 12 0° 23 Φ8 +0.015 +0.002 3-M3x6 5.2 15 6+0.05 2.4 53 6+0.05 TRD-2TH□A/B/AF/BF TRD-2TH□V/V1/VH 50MΩ min. 10~55Hz with 0.75mm Vibration resistance 2 Nominal core cross section Adjustment is made by the shaft notch (facing down). Operation 30N External diameter Φ30±0.2 Ambient temperature Thrust Weight Φ20+0.02 hole 0 ≤2V ― Radial Material 12 12 - Max. allowable speed 2TH□V/V1/VH 4-M4 set screw 19.1 4-M5 set screw R ε α 0± Φ3 S 46 Φ 0.2 7 *2 Env i r o n m e n t a l r e q u i r e m e n t s 0.3×10 6㎏·m2 2T□V/V1/VH、 ≥[(LPV)-4V] Between output and power supply Max. 0.01N·m(+20℃) 3-Φ3.5 hole ≥2.5V *2:LPV:Load power voltage Starting torque Max. allowable shaft load *3 OL7272 equivalent ≤30mA Shaft moment of inertia Cable 26LS31 equivalent ≤30mA M e c h a n i c a l s p e c i f i c at i o n s TRD-2T□A/B/AF/BF TRD-2T□V/V1/VH Line driver 26C31 equivalent Negative logic (active low) Short-circuit protection TRD-2T□A/B/AF/BF TRD-2T□V/V1/VH Line driver Inflow Load power supply voltage Se t t i n g i n d ex p o s i t i o n Line driver Output *1 with a cable of 1m ; Mount ing DC4.75V~28V Type No. Material RU-075 Aluminum alloy(7075) GJ-6 α 5°MAX Glass-fiber reinforced polyacetal resin 5°MAX ε s 0.25mmMAX 0.12mmMAX 0.5mmMAX 0.12mmMAX *5
Similar documents
Haas Technical Publications
Standard: 20 Station Carousel Tool Changer Option: 24+1 Side Mount Tool Changer
More information