SH-VT250-M2, VT250A-M2 Rev C
Transcription
SH-VT250-M2, VT250A-M2 Rev C
SH-VT250-M2, VT250A-M2 Rev C NDIR CO2 Dual sensor Needless calibration on long-term use Can measure over 95% RH condition Applicable to humid storage, mushroom farm and floricultural industry Communication Method RS-485 (Standard) 4~20 mA (Option) 0~5 V analog (Option) RoHS CO2, Temperature & Humidity Transmitter Applications - Ventilation Control - Heat Ventilation Air Conditioning System - Mushroom Farming Greenhouse - Greenhouse and Humid Storage - Floricultural Industry - Cold storage, vegetable storage SOHA TECH CO,.Ltd. Suite 104, Hagye technotown A,250-3, Hagye-dong,Nowon-gu,Seoul, Korea TEL : +82 -2-978-0461,2,5 FAX : +82-2-978-0463 http://www.soha-tech.com This product can be changed for quality improvement without notification. - 1 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C Input Power : DC 12 ~ 24 V, over 200 mA Features Power consumption: Normal 40 mA, Peak 135 mA Model: SH-VT250 = RS-485 Communication SH-VT250A = 4 ~20 mA output type SH-VT250V = 0 ~ 5 V output type CO2 (Carbon Dioxide), Temperature, Humidity Transmitter Analog output tupy : 4~20 mA Current Loop (option) : 0~5V (0ption) Communication output: RS485 Precision Temperature and Humidity sensor Can be connected with PLC or MICOM controller Suitable for humid and weeping water condition Low Cost, High Quality IP65 Protection grade - 2 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C CAUTION Cautions for the installation of SH-VT250 You have to install SH-VT250 in the direction of O mark. And don’t turn the power off when using SH-VT250. It causes dampness inside the product. In case of turn the power off, you have to store this product in non-condensing condition. When user spray agricultural pesticides, VT250 transmitter should be covered with plastic bag - 3 - www.soha-tech.com SH-VT250-M2, SPECIFICATIONS VT250A-M2 Rev C CO2 sensor List Contents Measuring method Remarks NDIR Measuring Range 0~3000/5000/10,000 ppm option Accuracy ±2% @10~50℃ Response time 0 ~ 80% < 30 Sec Signal update term Every 2.0 Seconds Warm-up Time @25℃ < 90Sec Working Temp Working Humidity @25℃ 0 ~ 50℃ ( -10~50℃ Option) 0 ~ 99.9% RH Temperature sensor List Contents Measuring Range Accuracy -25 ~ 85℃ (RS485) -10 ~ 50℃ (Analog) Remarks SH-VT250 SH-VT250A Max. ±0.4 ℃ ±0.3℃ . Response Time 5 ~ 30 sec Humidity sensor List Contents Measuring Range 0 ~ 99.9 %RH Accuracy ±2 %RH Response time 8 sec Remarks - 4 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C Communication Protocol 1. Data Transmission Format Byte 1 2 Contents STX ID Byte 15 14 Contents 3 4 5 6 7 9 CO2 Value 16 17 18 10 11 12 13 Temperature Value 19 Humidity Value 8 20 21 22 23 24 SHT Mode Check Sum CR LF Each content is displayed by ASCII type - STX: Start Code (0x02) - ID: Transmitter ID (Initial value : 0x00) - CO2 Value: a number of four byte ASCII cords - Temperature Value Display Below zero, 9th Byte is „-„(0x2D) Above zero, 9th Byte is Space(0x20) 12th Byte decimal point display is „.‟(0x2E) - Humidity Value Display 17th Byte decimal point display is „.‟(0x2E) - SHT: display condition of temperature and humidity sensors „0‟(0x30) = normal running „1‟(0x31) = measured temp. & humidity value error Or temp. & humidity sensor connection error (temp. & humidity data will be displayed former one) - Mode: „0‟(0x30) = data transmission every 2 sec „1‟(0x31) = data transmission when DTE needs data (Initial value : 0x30) - Check Sum: Sum of 1~21Byte, use low data 1Byte only - CR: 0x0D - LF: 0x0A - 3, 8, 14, 19 Byte: Space (0x20) ** Compare the Check Sum after receiving 24 Byte and check the error. ** If the value of SHT is „1‟, the measured temp. & humidity values are error. Or the connection wire of temp. & humidity has problems. In this case , transmitted data is former measured data - 5 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C 2. Set up Byte Contents 1 2 3 4 5 STX ID S Set ID Mode 6 7 Reserve 8 9 10 Check Sum CR LF - STX: Start Code (0x02) - ID: Transmitter ID ( if this byte set as 0x00 :every transmitter accepts command) - „S‟(0x53): set up Command - Set ID: Transmitter ID set(0x00 ~ 0xFF) - Mode: „0‟(0x30) = data transmission every 2 sec „1‟(0x31) = data transmission only when controller request data (Initial value : 0x30) - Reserve - Check Sum: Sum of 1~7Byte, use low data 1Byte only - CR: 0x0D - LF: 0x0A ** If user want to set Transmitter‟s ID, don‟t use 0x00. ( ID 0x00 has reserved as automatic transmission) If transmitter has set as some of specific ID except 0x00, it will respond automatically when transmitter receive 0x00 Call. This function allow you to set up transmitter, even if you don‟t know the ID. ** Notice : When many transmitter connected in parallel, if controller call ID 0x00 , every transmitter will respond. - 6 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C 3. Data Command (Mode „1‟only) Byte Contents 1 2 3 STX ID R 4 5 6 7 Reserve 8 9 10 Check Sum CR LF - STX: Start Code (0x02) - ID: Terminal ID - „R‟(0x52): Data request Command - ID set: Terminal ID set (0x00 ~ 0xFF) - Reserve - Check Sum: Sum of 1~7 Byte, use low data 1 Byte only - CR: 0x0D - LF: 0x0A Modbus protocol Modbus Address Map Address contents read Hex Dec (2 byte) /write 0x64 100 CO2 Value Read 0x66 102 Temperature Value Read 0x68 104 Humidity Value Read 0x6A 106 Temp. RH sensor error status read 0x00 0x30 : Normal 0x00 0x31 : Error 0x6C 108 Device ID read/write (Refer to additional description) ※ Notice: measured values of temperature and humidity must be divided by 10 before use the data. Ex) Read Value 253(0x00FD) -> Real Value 25.3℃, Read Value -123(0xFF85) -> Read Value -12.3℃, - 7 - www.soha-tech.com SH-VT250-M2, ※ When user apply Device ID writing instruction, VT250A-M2 Rev C DIP switch should be set as “1” before sending instruction. ID writing sequences are like bellows, 1. Turn off the power. 2. Set Dip S/W as “01” 3. Switch on the power. 4. Write Device ID . 5. Turn off the power again. 6. Set Dip S/W as “F” (1111). 7. Switch on the power again. 8. Device is ready to communicate as a set ID. [DIP S/W “1” (only No. 4 pin ON(UP)) - 8 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C Dip Switch setting method Data transmission every 2 sec ID 1 Setting, Data transmission when DTE needs data ID 2 Setting, Data transmission when DTE needs data ID 3 Setting, Data transmission when DTE needs data | | | | | | ID 14 Setting, Data transmission when DTE needs data When use ID(15 ~ 255) of which Serial communication set up * Note: When DIP switch value is “0“ (all dip switch are Off), serial communication setup is not available. Other dip switch setting except “0” are available of serial communication. Before set ID and apply new setting, Ex) power should be off. 1) Turn off the power 2) set dip switch (ID) 3) Switch on the power ※ Select output mode (SH-VT250A only) output OFF 0~5V output output OFF 4~20mA output - 9 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C - 10 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C - 11 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C ■ Analog wiring diagram - 12 - www.soha-tech.com SH-VT250-M2, VT250A-M2 Rev C ■ Dimension - 13 - www.soha-tech.com