FirePoint Datasheet Pack v4
Transcription
FirePoint Datasheet Pack v4
FirePoint Control Panel Features ■ Analogue/addressable detection devices ■ Digital processing based ■ LED zone indication ■ Keyswitch access ■ Laptop programming ■ Configurable system code ■ Device isolate ■ VHF remote receiver facility ■ Keypad programming ■ Integral pager transmitter Overview 5000 FirePoint is designed using EMS radio technology allowing flexibility and expansion of wireless fire detection systems. There are various panel options available with the added benefits of wireless installation. The fire alarm control panel incorporates state of the art radio technology, coupled with the panel features, providing the user with a cost effective and practical fire alarm panel. 5000 FirePoint uses industry standard devices such as the Ziton detector, KAC call point and the Signature Industries sounder. The analogue/addressable detectors, callpoints and sounders are alkaline battery powered with up to 5 years typical life cycle. The panel technology meets the requirements of BS5839 and EN54 standards and has been fully tested by the DTI to satisfy the requirements of MPT 1305 and 1328 radio standards. VHF technology is used for receiving information from devices and is combined with UHF (at 500mW) for command signals to radio sounders and personal pagers. The fire panel and its peripheral equipment benefit from over 20 years of design, development and manufacturing experience, providing leading edge solutions to complex radio technology problems. Optional system support facilities • Optional wireless (radio) local area network • Optional modem technical support • Interface compatibility with the EMS fire detection range Specification Dimensions: 330 x 450 x 116mm (Including back box) Fascia: Injection moulded, with steel backbox Colour: Two-tone contrasting beige Operating Temperature: -10 to 55 °C Humidity: Up to 75% non-condensing Power: 230Vac, 50Hz Battery Space: 2 x 12volt 9AH batteries (not supplied) Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (receiver) UHF - 458.5 MHz - 459.5 MHz (transmitter) Channel Spacing: 25 kHz Output Transmitter Power: 0.75W (500 Mw) (+27DBH) Outputs: 2 x .25amp 24v DC sounder output circuits individually fused with end of line by reverse polarity, open circuit & short circuit monitoring. 1 x hardwire call point with end of line, open circuit and short circuit monitoring. 2 x sets of auxiliary fire contacts. 2 x sets of auxiliary fault contacts. 1 x RS485 serial port 1 x RS232 serial port 1 x Power supply and charger 230VAC 50 Hz Transformer giving a total of 3 amps. Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Addressable 4 Zone Controller: Analogue Addressable 12 Zone Controller: Analogue Addressable 24 Zone Controller: Analogue Addressable 96 Zone Controller: Part Part Part Part Number Number Number Number 53 53 53 53 - 5004 5012 5024 5096 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 1, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Optical Detector Features ■ Analogue/addressable ■ Proprietary sensor ■ Protected sensing chamber ■ Universal transmitter module ■ Up to 5 Years battery life ■ Detector / transmitter tamper ■ Range in excess of 250 metres Overview The model 53-5100 Analogue Addressable Optical Smoke Detector is bayonet fitted to a radio address/transmitter module, incorporating alkaline batteries and supplied with a surface-mount base unit. Removal of the detector or address/transmitter module will indicate a fault condition. The detector is manufactured by Ziton and complies with BS5839 Part 5 and EN54 Part 7. The Optical Smoke Detector operates on an advanced light scattering principle, using a wide-angle light beam together with an extra high sensitivity photodiode receiver. An internal polling system checks for smoke particles every 5 seconds, initial detection of smoke traces accelerates polling to every 2 seconds. The alarm is verified twice to ensure freedom from false alarms. The detector incorporates a selectable automatic lock, which, if enabled locks it into its base when plugged in, preventing unauthorised removal. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The radio address module is programmed to report at regular intervals of 5 – 9 minutes. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The address/transmitter module is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery pack has been tested to provide up to 5 years life at normal site operations (10 - 30°C). The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, allowing 30 days for the battery pack to be changed before unit failure. Specification Dimensions: 106x75 mm with transmitter/address module Weight: 119g Operating Temperature: -10 to 85 °C Humidity: Up to 95% non-condensing Supply: 6 x 1.5 volt alkaline AAA cells Battery life up to 5 years (at normal site conditions 10 - 30°C) Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Detector alarm – Fire and Fault Detector identity Battery condition Auto report signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Detector / address module complete: Part Number 53 - 5100 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 2, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Callpoint Features ■ Fully addressable ■ Wireless activation ■ LED activation indication ■ Up to 5 Years battery life ■ Rear tamper protection ■ Range in excess of 250 metres Overview The model 5200 Radio Callpoint is battery operated, incorporating a radio address module. This eliminates the need for wiring back to the fire alarm control panel. The callpoint is designed to meet BS5839 part 2. The callpoint is fitted into an industry standard ABS moulding which allows for testing by insertion of a test key. When the glass is broken, the micro-switch is released, triggering an alarm transmission by radio, to the alarm panel. Each unit has a unique address configured during manufacture and is individually addressable by the system controller during commissioning. The unit is programmed to report at regular intervals of 5 – 9 minutes. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The Callpoint is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide up to 5 years of normal site operations. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, allowing 30 days for the battery pack to be replaced before unit failure. Specification Dimensions: 87 x 87 x 61.5mm Weight: 276g Operating Temperature: -10 to 55 °C Supply: 6 x 1.5 volt alkaline AAA cells Battery life up to 5 years (at normal site conditions 10 - 30°C) Operating Frequencies: Channel Spacing: Output Transmitter Power: Outputs: Standards: VHF - 173.2 MHz -173.5 MHz (transmitter) 25 kHz 1 mW ERP Alarm signal Callpoint identity Battery condition Auto report signal LED to confirm alarm transmission Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Red Radio Callpoint: White Radio Callpoint: Blue Radio Callpoint: Yellow Radio Callpoint: Green Radio Callpoint: Part Part Part Part Part Number Number Number Number Number 53 53 53 53 53 – – – – – 5200/R 5200/W 5200/B 5200/Y 5200/G An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 3, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Sounder Features ■ Fully addressable ■ Wireless activation ■ 2-way radio communication ■ 96Db(adjustable at 1 metre) ■ Sounder/Visual indicator option ■ Hardwired Callpoint option ■ Up to 5 Years battery life Overview The model 5300 Radio Sounder is a battery operated sounder remotely activated and monitored by the system 5000 FirePoint controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. Each unit is controlled individually or by zone, dependant on the system design. The Radio Sounder is housed in an industry standard, impact resistant ABS moulding. The sounder has 2-way radio communication with the fire system controller using UHF wavebands to receive command instructions and VHF for auto reporting. The model 5320 Radio Sounder has a set of monitored contacts for the wiring of a remote callpoint, thereby providing a very cost effective component. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The sounder is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide up to 5 years of normal site operations. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, leaving approximately 30 days for the battery pack to be changed. Specification Dimensions: 53-5300 = 88 x 88 x 93 mm Weight: 379g Operating Temperature: Humidity: -10 to 55 °C Up to 95% non-condensing Supply: 3 x 1.5 volt AA cells 3 x 1.5 volt C cells Battery life up to 5 years (at normal site conditions 10 - 30°C) Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) UHF - 458.5 MHz - 459.5 MHz (receiver) Standard Fire Tone 1024Khz,819Khz Channel Spacing: 25 kHz 1 mW ERP Output Transmitter Power: Outputs: 4 tone patterns Sounder identity Battery condition Auto report signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Radio Radio Radio Radio Radio Sounder Sounder Sounder Sounder Sounder (red): (red) weather resistant: (white): Visual indicator: with Auxiliary contacts: Part Part Part Part Part Number Number Number Number Number 53 53 53 53 53 – – – – – 5300/R 5300/RWP 5300/W 5310 5320 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 4, v1.3 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Heat Detector Features ■ Analogue/addressable ■ Proprietary sensor ■ Universal transmitter module ■ Up to 5 Years battery life ■ Detector / transmitter tamper ■ Range in excess of 250 metres Overview The model 5120 Analogue Addressable Heat Detector is bayonet fitted to a radio address/transmitter module, incorporating alkaline batteries and supplied with a surface-mount base unit. Removal of the detector or address/transmitter module will indicate a fault condition. The detector is manufactured by Ziton limited and complies with BS5839 Part 5 and EN54 Part 5 (Class B) and part 8 (Class B). The Heat Detector operates on a highly sensitive thermistor, which measures actual temperature and the rate of temperature rise change. At regular intervals, the detector carries out a self test that checks and verifies every function, including the thermistor and sensitivity to temperature. Any failure is automatically reported to the control panel. The detector incorporates a selectable automatic lock, which, if enabled locks it into its base when plugged in, preventing unauthorised removal. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The radio address module is programmed to report at regular intervals of 5 – 9 minutes. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The address/transmitter module is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery pack has been tested to provide up to 5 years life at normal site operations (10 - 30°C). The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, leaving approximately 30 days for the battery pack to be changed. Specification Dimensions: 106 x 75 mm with transmitter/address module Weight: 119g Operating Temperature: -10 to 85 °C Humidity: Up to 95% non-condensing Supply: 6 x 1.5 volt Alkaline AAA cells Up to 5 years battery life (at normal site conditions 10 - 30°C) Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Detector alarm – Fire and Fault Detector identity Battery condition Auto report signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Detector / address module complete: Part Number 53 - 5120 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 5, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Combined Detector Sounder Features ■ Analogue/addressable ■ Proprietary sensor ■ Unique 1st stage audible alert feature, designed for hotels etc ■ 2-Way radio communication ■ Up to 5 Years battery life ■ Selectable tone patterns for: fire, fire evacuation, bomb alert & class change ■ Device removal detection ■ Range in excess of 250 metres Overview Designed and manufactured using the latest techniques including surface-mount technology, the combined detector / sounder offers easy and quick installation with the added benefit of a lower quantity of physical devices required for a system. The sounder section of the unit consists of its own integral energy source of up to 5 years and is remotely activated and monitored by the system 5000 FirePoint controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The address module base is compatible with the range of system 5000 FirePoint heads; these include optical, heat and combined sensor heads. The sounder element is designed to be omni – directional with an output of 90 dBA at 1 metre. Making it ideal for hotels, boarding schools and nursing homes where a detector and sounder would be required in each room. The internal polling of the sensor is every 5 seconds, which accelerates to every 2 seconds when traces of smoke are detected. The alarm is then verified twice to ensure freedom from false alarms. Specification Dimensions: 145 x 90mm Weight: 650g Operating Temperature: -10 to 85 °C Humidity: Up to 95% non-condensing Supply: Up to 5 years integral energy source Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) UHF - 458.5 MHz - 459.5 MHz (receiver) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Detector alarm Detector fault Detector pre-alarm Detector tamper Battery condition Call in signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Combined sounder & optical detector: Combined sounder & heat detector: Part Number 53 - 5191 Part Number 53 - 5192 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 6, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Input / Output Unit Features ■ Fully addressable ■ Wireless activation ■ 2-way radio communication ■ Volt free relay output ■ Monitored input for fire & fault ■ Up to 5 Years battery life ■ Rear tamper protection ■ Range in excess of 250 metres Overview The EMS wireless input/output device is a battery operated device remotely activated and monitored by the System 5000 FirePoint controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The input/output unit provides the facility to transmit alarm signals from a beam smoke detector system, aspirating detection and reporting to other fire related systems or products. The radio input transmitter is fully monitored for fire and fault conditions. The unit provides the facility to operate various contact operated devices such as magnetic door holders. The standard unit is capable of switching 24 volts Dc at a maximum of 1 amp. Mains switching units are also available. Specification Dimensions: 250mm x 160mm x 40mm Injection moulded Operating Temperature: -10 to 55 °C Humidity: Up to 95% non-condensing Supply: Up to 5 years integral energy source Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) UHF - 458.5 MHz - 459.5 MHz (receiver) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Standards: Volt free contact rated 24vdc at 1 amp “Call in” Signalling Battery condition reporting Designed to comply with EN54 part 18 Ordering Information Addressable I/O unit: I/O unit with external aerials: Mains Switching I/O: Part Number 53 - 5610 Part Number 53 - 5610/MH Part Number 53 - 5620/230V An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 7, v1.3 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Dual Sensor Features ■ Analogue/addressable ■ Proprietary sensor ■ Universal transmitter module ■ Up to 5 years battery life ■ Detector / transmitter tamper ■ Ziton Sensor alarm management (Verification) using dual technology ■ Range in excess of 250 metres Overview The dual technology analogue addressable (combined) optical / heat detector is bayonet fitted to a radio address / transmitter module incorporating an integral energy source of up to 5 years. It is supplied with a surface-mount base unit. Removal of the detector or address / transmitter module will indicate a fault condition. The heat detector section of the head operates on a highly sensitive thermistor, which measures actual temperature and the rate of temperature rise change. At regular intervals, the detector carries out a self- test that checks and verifies every function. The optical detector section of the head operates on an advanced light scattering principle, using a wide-angle light beam together with an extra high sensitivity photodiode receiver. The internal polling system checks for smoke particles every 5 seconds, initial detection of smoke traces accelerates polling to every 2 seconds. The alarm is then verified twice to ensure freedom from false alarms. When used in its dual technology verification mode, both heat and optical smoke detection properties have to be activated again with 4 sensitivity levels, before sending the alarm status to the controller. Specification Dimensions: 106 x 75 mm Weight: 119g Operating Temperature: -10 to 55 °C Humidity: Up to 95% non-condensing Supply: Up to 5 years integral energy source Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Detector alarm Detector fault Detector pre-alarm Battery condition Call in signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Dual Sensor complete: Part Number 53 - 5150 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 8, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Radio LAN Module Features ■ Typical range in excess of 500 metres ■ Fully monitored ■ Networking via radio (up to 27 panels) ■ Mains powered with battery backup ■ High strength steel enclosure ■ 485 bus connection to EMS System 5000 fire panel Overview The 5000 FirePoint range of controllers is capable of being expanded using network signalling. This can be achieved with the connection of a 53-5438 Radio LAN module to the RS-485 Bus of the control panel. Up to 27 panels can be radio linked on a site, giving device and signal expansion for up to 7560 radio devices. The Radio LAN is fully monitored by the system controllers and gives the added ability to control mimic / repeater panels Utilising the functionality of the Radio LAN eliminates the need for excess cable runs between control panels, this not only cuts the overall installation cost of the system, but also considerably reduces the amount of time required for installation. Specification Dimensions: Operating Temperature: 390 x 320 x 80mm -10 to 55 °C Humidity: Up to 75% non-condensing Supply: 230 V Operating Frequencies: UHF - 458.5 MHz - 459.5 MHz (receiver) Channel Spacing: 25 kHz Output Transmitter Power: 500 mW ERP Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information LAN Module Part Number 53 - 5438 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 9, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint High Gain Aerials DIMENSIONS: 660mm Long DIMENSIONS: 660mm Long OPERATING FREQUENCIES: OPERATING FREQUENCIES: UHF 458.5 - 459.5 Mhz UHF 458.5 – 459.5 Mhz Ordering information : 5-5501 (UHF high gain aerial complete with 3m RG58 cable and fixing bracket). 5-5501/BP10 (UHF high gain aerial complete with mounting bracket, extension pole & 10m RG213 cable). 5-5501/BP20 (UHF high gain aerial complete with mounting bracket, extension pole & 20m RG213 cable). 5-5501/BP30 (UHF high gain aerial complete with mounting bracket, extension pole & 30m RG213 cable). Ordering information : 5-7329 (UHF 3dB high gain aerial). 5-7329/BP10 (UHF 3dB high gain aerial c/w mounting bracket, extension pole & 10m RG213 cable). 5-7329/BP20 (UHF 3dB high gain aerial c/w mounting bracket, extension pole & 20m RG213 cable). 5-7329/BP30 (UHF 3dB high gain aerial c/w mounting bracket, extension pole & 30m RG213 cable). DIMENSIONS : 160mm Long DIMENSIONS: 160mm Long OPERATING FREQUENCY :VHF 173Mhz OPERATING FREQUENCY :UHF 458Mhz Ordering information : Ordering information : 5-5521 (UHF helical aerial supplied with BNC connector) 5-5520 (VHF helical aerial supplied with BNC connector) DIMENSIONS: 860mm Long DIMENSIONS: 540mm OPERATING FREQUENCY: OPERATING FREQUENCY: VHF 173 Mhz UHF 458.5 – 459.5 Mhz Ordering information : Ordering information : 5-5500 (VHF high gain aerial complete with 10m RG58 cable and fixing bracket). 5-5500/BP10 (VHF high gain aerial complete with mounting bracket, extension pole & 10m RG213 cable). 5-5500/BP20 (VHF high gain aerial complete with mounting bracket, extension pole & 20m RG213 cable). 5-5500/BP30 (VHF high gain aerial complete with mounting bracket, extension pole & 30m RG213 cable). 5-7326/BP10 (UHF directional aerial bracket, extension pole & 10m RG213 5-7326/BP20 (UHF directional aerial bracket, extension pole & 20m RG213 5-7326/BP30 (UHF directional aerial bracket, extension pole & 30m RG213 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 10, v1.2 c/w mounting cable). c/w mounting cable). c/w mounting cable). Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Combined Voice Sounder Sensor Features ■ Proprietary sensor st ■ Unique 1 stage audible alert feature, designed for hotels etc ■ Programmable Alert message ■ Up to Four messages ■ 2-Way radio communication ■ Up to 3 Years battery life ■ Device removal detection ■ Range in excess of 250 metres Overview Designed and manufactured using the latest techniques including surface-mount technology, the combined detector / voice sounder offers quick and easy installation with the added benefit of a lower quantity of physical devices required for a system. he wireless voice message evacuation / smoke detection device is a battery operated unit, remotely activated and monitored by the 5000 FirePoint controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. Each unit can produce up to 4 separate fully synchronised, locally stored audio messages. These messages can be triggered either by a standard EMS 5000 FirePoint control panel or a separate voice evacuation controller. The sounder section of the unit consists of its own integral energy source, typically lasting up to 3 years and is remotely activated and monitored by the 5000 FirePoint controller. The detection section of the unit is available with various options; these include optical, heat and combined sensor heads. The sounder element is designed to be omni – directional with an output of 90 dBA at 1 metre. Making it ideal for hotels, boarding schools and nursing homes where a detector and sounder would be required in each room. The internal polling of the sensor is every 5 seconds, which accelerates to every 2 seconds when traces of smoke or heat are detected. The alarm is then verified twice to ensure freedom from false alarms. Specification Dimensions: 145 x 90mm Weight: 650g Operating Temperature: -10 to 85 °C Humidity: Up to 95% non-condensing Supply: Up to 3 years integral energy source Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) UHF - 458.5 MHz - 459.5 MHz (receiver) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Detector alarm Detector fault Detector pre-alarm Detector tamper Battery condition Call in signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Voice sounder with Optical Sensor: Voice Sounder with Dual Sensor: Voice Sounder with Heat Sensor: Part Number 53 - 5196 Part Number 53 - 5165 Part Number 53 - 5197 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 11, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Transponder Features ■ Fully addressable ■ Wireless signalling path ■ Dual frequency radio communication ■ Monitored for fault ■ Mains powered ■ Tamper protection ■ Range in excess of 500 metres Overview The EMS wireless transponder is a mains powered device that is used to enhance the signalling range of EMS 5000 FirePoint detection devices, without the need to use hardwired range extenders. The units are supplied with their own integral power supply and battery backup. The 5000 FirePoint transponder is compatible with our entire range fire control panels when the controller is coupled to a UHF remote receiver, connected to the RS485 BUS of the 5000 FirePoint controller. Specification Dimensions: Transponder 390mm x 320mm x 80mm Remote Receiver 390mm x 320mm x 80mm Operating Temperature: -10 to 55 °C Humidity: Up to 95% non-condensing Supply: 230v 50Hz Operating Frequencies: VHF - 173.2 MHz -173.5 MHz UHF - 458.5 MHz - 459.5 MHz Channel Spacing: 25 kHz Output Transmitter Power: 500 mW ERP Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information VHF Signal Transponder UHF Remote Reciever Part Number 53 – 5400 Part Number 53 – 5428 An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 12, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. Radio Door Closer Features ■ Fast, automatic fire door release when alarm sounds ■ Installs in under five minutes ■ Easy, foot-operated manual release / adjustment operation ■ Reliable, acoustic detection ■ Smart, unobtrusive design ■ Integral power-on LED indicator ■ Low battery, automatic door release ■ Optional floor plate for especially heavy doors / slippery floor surfaces ■ No unsightly cabling Overview Wedging open a fire door is illegal, dangerous and opens you, the employer, to the risk of personal prosecution. Because as an integral part of any building’s fire safety strategy, the fire doors are routinely propped open with wedges, waste bins, fire extinguishers or whatever else may be close at hand so people can move as quickly and as easily as possible, whatever they may be carrying or pushing. Understandable perhaps, but incredibly dangerous and in direct contravention of the UK Fire Precautions (Workplace) Regulations 1997. In the event of a fire, this hazardous practice will almost certainly guarantee the fire spreads more quickly, causes more damage and ultimately, puts people’s lives and property under much greater threat. It can also count against subsequent insurance claims. There is a cost-effective alternative. One that can keep each and every one of your fire doors open at any time of day or night, and can do so, easily, safely and legally. Radio door close is the simple, reliable acoustic device that holds a fire door open in any position and then automatically releases the door should a fire alarm sound. Inexpensive to buy, Radio door close is also quick and easy to install. It simply screw-fits to the bottom of the chosen fire door in a matter of minutes with no risk to the fire door’s integrity. The unit’s rubber plunger/stopper is in contact with the floor and unlike magnetic retainers, can hold the door open in any selected position. When a fire alarm sounds, Radio door close’s integral audio-electronic device signals the plunger stopper to retract and releases the door to close. Radio door close is battery operated so there is no need for complex and expensive wiring. Fast, simple and already effective in thousands of buildings across the UK today. Recognised and endorsed by fire industry institutions, reduce your fire risk with Radio door close – your automatic, inexpensive door retainer solution. Specification Dimensions: 153 x 195 x 45mm Operating Temperature: -10 to 55 °C Humidity: Up to 95% non-condensing Supply: Door Release: 2 x 1.5v “C” cells Radio TX Unit: 2 x 1.5v “C” cells Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Acoustically Operated Door Close: Doorgard X (Transmitter Unit): Doorgard X (Radio Door Release Unit): Part Number 53 - ADR/B Part Number 53 - RDT/W Part Number 53 - 53-RDR/B An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 13, v1.2 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. FirePoint Sounder Sensor Visual Indicator Features ■ Analogue/addressable ■ Proprietary sensor ■ LED Flashing visual indicator ■ Unique 1st stage audible / visual alert feature, designed for hotels, DDA, etc ■ 2-Way radio communication ■ Up to 5 Years battery life ■ Selectable tone patterns for: fire evacuation, bomb, alert & class change ■ Device removal detection ■ Range in excess of 250 metres Overview Designed and manufactured using the latest techniques, including surfacemount technology the combined detector / sounder / visual indicator offers quick and easy installation with the added benefit of a lower quantity of physical devices required for a system. The sounder / visual indicator part of the unit consists of its own integral energy source of up to 5 years and is remotely activated and monitored by the system 5000 FirePoint controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The device is available with detector options for optical, heat and multi-sensor heads. The sounder element is designed to be omni – directional with an Output of 90 dBA at 1 metre. Making it ideal for hotels, boarding schools and nursing homes where a detector and sounder would be required in each room, with the added benefit of the LED beacon designed to comply with the requirements of the DDA. The internal polling of the sensor is every 5 seconds, which accelerates to every 2 seconds when traces of smoke are detected. The alarm is then verified twice to ensure freedom from false alarms Specification Dimensions: 145 x 90mm Operating Temperature: -10 to 55 °C Humidity: Up to 95% non-condensing Supply: Up to 5 years integral energy source Operating Frequencies: VHF - 173.2 MHz -173.5 MHz (transmitter) UHF - 458.5 MHz - 459.5 MHz (receiver) Channel Spacing: 25 kHz Output Transmitter Power: 1 mW ERP Outputs: Detector alarm Detector fault Detector pre-alarm Detector tamper Battery condition Call in signal Standards: Designed to comply with relevant parts of BS5839 and EN54 Ordering Information Combined Sounder Optical Sensor Visual Indicator Combined Sounder Heat Sensor Visual Indicator Part Number 53 – 5191/S Part Number 53 – 5192/S An ISO9001:2008 approved company EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] www.emsgroup.co.uk Part No: FirePoint 14, v1.3 Dealer Information: The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.