THE MONASTERY of JERONIMOS, LISBON, PORTUGAL
Transcription
THE MONASTERY of JERONIMOS, LISBON, PORTUGAL
NEW INTEGRATED KNOWLEDGE BASED APPROACHES TO THE PROTECTION OF CULTURAL HERITAGE FROM EARTHQUAKE INDUCED RISK FP7-ENV-2009-1 COORDINATOR: Case Study Monastery of Jerónimos, Lisbon, Portugal Paulo B. Lourenço Universidade do Minho Department of Civil Engineering Guimarães, Portugal NIKER Workshop, Israel, December 16-17, 2012 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 2 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Description Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 3 The crown asset of Portuguese heritage buildings Construction from 1499 Built with limestone Considerable dimensions in plan, more than 300 50 m2, and an average height of 20 m (50 m in the towers) Evolves around two courts. The larger court is bordered by a long arcade of two levels that hosts the Ethnographic Museum of Archaeology and the Maritime Museum. The smaller court or the Cloister is bordered by the Church, the Sacristy, the Chapter Room, the Refectory Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Local Seismicity Gathered data Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 4 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço | 5 5 Church 5 1 3 4 2 6 5 Cross -section Views Institute for Sustainability and Innovation in Structural Engineering Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço In situ investigation Tiles removal for visual inspection Wallets for supporting tiles (20th century) Institute for Sustainability and Innovation in Structural Engineering Radar inspection Ribs visual inspection | 6 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço In situ geometrical survey Transept cross-section Longitudinal cross-section Nave cross-sections Plan of the nave Institute for Sustainability and Innovation in Structural Engineering | 7 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço Tilting of the columns and GPR of the columns Institute for Sustainability and Innovation in Structural Engineering | 8 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Modal Identification of the Church Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 9 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Mode I Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 10 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Mode II Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 11 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço | 12 Static Monitoring System (I) Measure deformations and temperature variations of two columns in the main nave The system is focused on the columns structural observation, because they are the best measure of the nave structural behavior C2 TS1 TS4 TS2 C2 TS5 TS6 C1 TS3 D TS4 TS4 Institute for Sustainability and Innovation in Structural Engineering TS3 C1 TS2 TS1 Paulo B. Lourenço Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal | 13 Static Monitoring System (II) North Tiltmeter (Daily Moving Average) 0.1 25 0.0 20 -0.1 15 -0.2 10 -0.3 5 Temperature [ºC] 30 Temperature Date Date North Tiltmeter vs Temperature 0.3 Rotation [mm/m] 0.2 0.1 0.0 -0.1 -0.2 Temperature [ºC] Institute for Sustainability and Innovation in Structural Engineering 35.0 30.0 25.0 20.0 15.0 5.0 -0.3 10.0 0.2 35 North Tiltmeter Sep-05 Oct-05 Nov-05 Dec-05 Jan-06 Feb-06 Mar-06 Apr-06 May-06 Jun-06 Jul-06 Aug-06 Sep-06 Oct-06 Nov-06 Dec-06 Jan-07 Feb-07 Mar-07 Apr-07 May-07 Jun-07 Rotation [mm/m] 0.3 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço | 14 Dynamic Monitoring System (I) Accelerations measurements in two points: in the base and in the main nave Due to the different technical characteristics and sampling rates data acquisitions, the dynamic monitoring system is physically separated from the static one. A1 A2 Legenda: Cablagem SENSORES Cn A1 TSn An D Clinómetro ( Temperatura Acelerómetr Sistema de a de dados Legenda: Notas: - Todas as cotas deve Cablagem SENSORES: Cn TSn An D Clinómetro (número) Temperatura na superfície (número) Acelerómetro (número) Sistema de aquisição e armazenamento de dados Notas: Institute for Sustainability and Innovation in Structural Engineering - Todas as cotas devem ser confirmadas no local Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço | 15 1st Frequency versus Temperature 4.2 4.1 4.0 3.9 3.8 3.7 3.6 3.5 Estimated Model 98% CI Series4 Date Institute for Sustainability and Innovation in Structural Engineering Apr-07 Feb-07 Estimated Model 98% CI Upper CI Oct-06 Aug-06 Jun-06 Date Apr-06 Feb-06 Feb-05 4.2 4.1 4.0 3.9 3.8 3.7 3.6 3.5 Dec-05 Confidence Intevals Dec-06 35 Oct-05 30 Aug-05 15 20 25 Temperature [ºC] Jun-05 10 Apr-05 5 Frequency [Hz] Frequency [Hz] Dynamic Monitoring System (II) Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Full Building Analysis Paulo B. Lourenço | 16 1 Full model with 135.000 dof6 Modal superposition Non-linear with equivalent static loading Deformed Nó 21747 Torremesh 1.3 25.49 1.2 22.60 1.1 16.11 Factor de Carga 1.0 11.36 0.9 0.8 0.7 4.71 0.6 3.48 0.5 2.48 0.4 0.3 0.2 0.1 0.0 0.00 1.34 0.87 0.43 5.00 10.00 15.00 20.00 Deslocamento z (cm) Institute for Sustainability and Innovation in Structural Engineering 25.00 Load-displacement diagram 30.00 Details Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Nave Analysis | 17 1 7 2.5 2.0 Load Factor Paulo B. Lourenço Non-linear Analysis: Loading = Self-weight ft = 0 fc, masonry = 6 N/mm2 fc, infill = 1 N/mm2 1.5 1.0 Column 0.5 Vault key 0.0 0.00 0.10 0.20 0.30 Vertical displacement (m) Load displacement diagram Institute for Sustainability and Innovation in Structural Engineering Incremental deformed mesh Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Transept Analysis | 18 1 8 1.8 1.6 Load Factor Paulo B. Lourenço 1.4 1.2 1 0.8 0.6 0.4 0.2 0 0 0.05 0.1 0.15 0.2 0.25 0.3 Vertical displacement (m) Incremental deformed mesh Load-displacement diagram Max. principal strains Institute for Sustainability and Innovation in Structural Engineering Min. principal stresses Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Laboratory Testing Stone and masonry testing Institute for Sustainability and Innovation in Structural Engineering Paulo B. Lourenço | 19 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Model for Dynamic Analysis Paulo B. Lourenço | 20 2 0 3D beam element model Calibration of the model – Dynamic identification Institute for Sustainability and Innovation in Structural Engineering Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Results Paulo B. Lourenço | 21 Seismic action vs. horizontal displacement envelop for different nodes Example of column response in Institute analysis for Sustainability and Innovation in Structural Engineering dynamic Example of collapse mechanism Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço Rz [kN] 5000 yrp earthquake 0 -500 -1000 -1500 -2000 -2500 -3000 -3500 -4000 -4500 Norte (nó 3633) Sul (nó 3651) 0 2 4 6 8 10 12 14 16 18 20 tempo (s) Vertical reaction in the columns General view of the failure Institute for Sustainability and Innovation in Structural Engineering mechanism Failure mode for the church 22 | 22 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Paulo B. Lourenço Virtual Collapse Mechanisms Vertical loading North façade Institute for Sustainability and Innovation in Structural Engineering South façade | 23 Seismic safety assessment of the church of monastery of Jeronimos, Lisbon, Portugal Possible Strengthening Measures Paulo B. Lourenço | 24 2 4 1: Pre-stress the columns 2: Load transfer 3: Increase column strength Institute for Sustainability and Innovation in Structural Engineering Case Study Monastery of Jerónimos, Lisbon, Portugal Paulo B. Lourenço [email protected] www.civil.uminho.pt/masonry