AAC BARE OVERHEAD SUPPORTING NEUTRAL
Transcription
AAC BARE OVERHEAD SUPPORTING NEUTRAL
AAC BARE OVERHEAD SUPPORTING NEUTRAL AAC - All Aluminum Conductor - 1350 Series Alloy Engineering Specifications: Standards: ASTM B230: Standard Specification for Aluminum 1350-H19 Wire for Electrical Purposes. ASTM B231: Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors. Construction: Conductors: Stranded, Concentric-Lay Aluminum Conductors,1350 Series Alloy per ASTM B231. Assembly: AAC bare overhead supporting neutrals are concentric-lay-stranded aluminum alloy 1350 conductors with a straight, round central wire surrounded by one or more layers of helically applied wires. Outer layer has right-handed lay. APPLICATIONS: Suitable for overhead transmission and distribution applications that do not require the rated strength of ACSR type neutrals. Encore's AAC overhead neutrals include Class AA for bare conductors usually used in overhead lines, and/or Class A for conductors to be covered with weather-resistant materials. Class A also for bare conductors where greater flexibility is required. ➊Concentric Stranded All Aluminum Conductor (AAC), 1350 Series Alloy AAC BARE OVERHEAD SUPPORTING NEUTRAL AAC - ALL ALUMINUM CONDUCTOR - 1350 SERIES ALLOY AWG Area Code Word KCMIL (mm²) Peachbell Rose Iris Pansy Poppy Aster Phlox Oxlip Daisy Tulip Canna Cosmos Dahlia Orchid Petunia Arbutus Magnolia Bluebell 6 4 2 1 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477.0 556.5 636.0 750.0 795.0 954.0 1033.5 13.3 21.1 33.6 42.4 53.5 67.4 85.0 107.2 135.2 170.5 201.4 241.1 282.0 322.3 380.0 402.8 483.4 523.7 Resistance DC Resistance at 20C AC Resistance at 60 Hz (Ohms/1000ft) Nominal Diameters Conductor Sizes Area (in²) No. of Strands 0.0206 0.0328 0.0522 0.0657 0.0829 0.1045 0.1317 0.1662 0.2095 0.2644 0.3124 0.3744 0.4369 0.4995 0.5893 0.6245 0.7495 0.8114 7 7 7 7 7 7 7 7 7 19 19 19 19 37 37 37 37 37 Reactance @ 60 Hz 1 ft. equiv. spacing (Megohms/1000ft) Class Each Finished Approximate Rated Net Weight Strength Strand OD (lbs) (in) (in) (lbs/1000 ft) DC 20°C AC 25°C AC 50°C AC 50°C Capacitive Inductive Ampacity (Amps) A A AA, A AA, A AA, A AA, A AA, A AA, A AA A AA, A AA AA AA, A AA AA AA AA 0.0612 0.0772 0.0974 0.1093 0.1228 0.1379 0.1548 0.1739 0.1953 0.1331 0.1446 0.1584 0.1711 0.1311 0.1424 0.1466 0.1606 0.1671 0.661 0.416 0.261 0.207 0.164 0.130 0.103 0.0820 0.0648 0.0513 0.0435 0.0363 0.0311 0.0272 0.0230 0.0217 0.0181 0.0167 0.673 0.423 0.266 0.211 0.167 0.133 0.105 0.0835 0.0663 0.0527 0.0445 0.0373 0.0320 0.0282 0.0251 0.0227 0.0191 0.0177 0.739 0.465 0.293 0.232 0.184 0.146 0.116 0.0917 0.0727 0.0578 0.0489 0.0409 0.0352 0.0309 0.0263 0.0248 0.0208 0.0193 0.806 0.506 0.318 0.253 0.200 0.159 0.126 0.100 0.0794 0.0629 0.0534 0.0445 0.0383 0.0335 0.0286 0.0269 0.0227 0.0210 0.7660 0.7296 0.6929 0.6716 0.6550 0.6346 0.6188 0.6029 0.5810 0.5600 0.5490 0.5330 0.5220 0.5110 0.4980 0.4940 0.4790 0.0473 0.1193 0.1140 0.1087 0.1061 0.1034 0.1008 0.0981 0.0955 0.0926 0.0888 0.0869 0.0848 0.0830 0.0811 0.0792 0.0780 0.0763 0.0756 103 138 185 214 247 286 331 383 443 513 570 639 703 765 847 878 982 1031 0.184 0.232 0.292 0.328 0.368 0.414 0.464 0.522 0.586 0.665 0.723 0.792 0.856 0.918 0.997 1.026 1.124 1.170 24.6 39.1 62.2 78.4 98.9 124.8 157.2 198.4 250.2 315.5 372.9 446.8 521.4 596.0 703.2 745.3 894.5 968.4 563 881 1350 1640 1990 2510 3040 3830 4830 6150 7110 8360 9750 11400 13100 13900 16400 17700 DC Resistance based on 16.95 Ohms-cmil/ft (20°C); 61.20% IACS per ASTM B231. AC Resistance at 60Hz. Ampacity based on 75°C conductor temp; 25°C ambient temp; 0.5 coefficients emissivity and absorption; 2ft./sec wind; 961 watts/sq. foot sun. 46 800.962.9473 www.encorewire.com TYPE duplex - EC-1350 SERIES ALUMINUM - overhead service DROP / 600V AAC 1350 - ALL ALUMINUM CONDUCTOR SUPPORTING NEUTRAL Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductor: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded All Aluminum Conductor (AAC), 1350 Series Alloy Bare Neutral Conductor per ASTM B230; ASTM B609; ASTM B231. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Duplex overhead service drop cable with AAC Series 1350 alloy neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Duplex overhead service drop cable has one black XLPE insulated aluminum conductor cabled around a bare stranded AAC 1350 alloy supporting neutral. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Conductor is surface printed for identification. ➊ ➋ ➊XLPE Insulation ➋Compact Stranded Aluminum Conductor, EC-1350 Series ➌Concentric Stranded All Aluminum Conductor (AAC), ➌ EC-1350 Series Supporting Neutral TYPE DUPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD ALUMINUM SERVICE DROP - 600V AAC 1350 - ALL ALUMINUM CONDUCTOR SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) Collie Spaniel Doberman Malemute 6-6 4-4 2-2 1/0-1/0 Bare Neutral Conductor Insulation Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) 6 4 2 1/0 7 7 7 10 0.045 0.045 0.045 0.060 0.259 0.303 0.358 0.456 Type Size (AWG) No. of Strands Rated Strength (lbs) AAC AAC AAC AAC 6 4 2 1/0 7 7 7 7 563 881 881 881 Diameter of Final Approximate Finished *Ampacity Construction Net Weight OD (XLPE) (in) (lbs/1000 ft) (in) 0.169 0.213 0.268 0.336 110 145 195 260 0.428 0.516 0.626 0.792 65 90 150 235 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 800.962.9473 www.encorewire.com 47 TYPE TRIplex - EC-1350 series ALUMINUM - overhead service DROP - 600V AAC 1350 - all aluminum conductor supporting neutral Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM 233; ASTM B836; ARRA 2009/FAR Subpart 25.6 “Buy American” Compliant. Construction: Conductors: Insulated Conductors: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded All Aluminum Conductor (AAC), 1350 Series Alloy Bare Neutral Conductor per ASTM B230; ASTM B609; ASTM B231. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Triplex overhead service drop cable with AAC 1350 Series alloy neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare stranded AAC 1350 Series alloy supporting neutral. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C for operation. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductors are surface printed for identification. ➊ ➌ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Concentric Stranded All Aluminum Conductor (AAC), 1350 Series Supporting Neutral ➋ TYPE TRIPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V AAC 1350 - ALL ALUMINUM CONDUCTOR SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) Patella Oyster Clam Purpura Nassa Melita Portunus 6-6-6 4-4-4 2-2-2 1/0-1/0-1/0 2/0-2/0-2/0 3/0-3/0-3/0 4/0-4/0-4/0 Bare Neutral Conductor XLPE Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) 6 4 2 1/0 2/0 3/0 4/0 7 7 7 10 12 15 19 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.259 0.303 0.358 0.456 0.496 0.543 0.595 Type Size (AWG) No. of Strands Rated Strength (lbs) AAC AAC AAC AAC AAC AAC AAC 6 4 2 1/0 2/0 3/0 4/0 7 7 7 7 7 7 7 563 881 1350 1990 2510 3310 4020 Diameter of Final Approximate Finished *Ampacity Construction Net Weight OD (XLPE) (in) (lbs/1000 ft) (in) 0.169 0.213 0.268 0.336 0.376 0.423 0.475 110 145 195 260 300 350 405 0.552 0.645 0.763 0.971 1.056 1.157 1.267 120 160 240 375 470 560 700 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 48 800.962.9473 www.encorewire.com TYPE QUADRUPLEX - EC-1350 series aluminum - overhead service DROP - 600V AAC 1350 - ALL ALUMINUM CONDUCTOR SUPPORTING NEUTRAL Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM 233; ASTM B836; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductors: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded All Aluminum Conductor (AAC), 1350 Series Alloy Bare Neutral Conductor per ASTM B230; ASTM B609; ASTM B231. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Quadruplex overhead service drop cable with AAC 1350 alloy neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Quadruplex overhead service drop cable has three black XLPE insulated aluminum conductors cabled around a bare stranded AAC 1350 alloy supporting neutral. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C for operation. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductors are surface printed for identification. ➊ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Concentric Stranded All Aluminum Conductor (AAC), ➌ EC-1350 Series Supporting Neutral ➋ TYPE QUADRUPLEX - EC-1350 ALUMINUM - OVERHEAD SERVICE DROP - 600V AAC 1350 - ALL ALUMINUM CONDUCTOR SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) Pinto Mustang Shire Criollo Percheron Hanoverian Oldenburg 4-4-4-4 2-2-2-2 1-1-1-1 1/0-1/0-1/0-1/0 2/0-2/0-2/0-2/0 3/0-3/0-3/0-3/0 4/0-4/0-4/0-4/0 Bare Neutral Conductor XLPE Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) 4 2 1 1/0 2/0 3/0 4/0 7 7 8 10 12 15 19 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.303 0.358 0.389 0.456 0.496 0.543 0.595 Type Size (AWG) No. of Strands Rated Strength (lbs) AAC AAC AAC AAC AAC AAC AAC 4 2 1 1/0 2/0 3/0 4/0 7 7 7 7 7 7 7 881 1350 1640 1990 2510 3040 3830 Finished OD (in) Ampacity (XLPE) 0.213 0.268 0.299 0.336 0.376 0.423 0.475 135 175 205 240 280 325 375 Diameter of Final Approximate Construction Net Weight (in) (lbs/1000 ft) 0.727 0.859 0.934 1.094 1.190 1.303 1.428 210 320 410 500 635 775 960 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 800.962.9473 www.encorewire.com 49 ACSR BARE OVERHEAD SUPPORTING NEUTRAL ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED - 1350 SERIES ALLOY WITH STEEL SUPPORT CENTER WIRE ENGINEERING SPECIFICATIONS Standards ASTM B230: Standard Specification for Aluminum 1350-H19 Wire for Electrical Purposes ASTM B232: Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) CONSTRUCTION Conductors Stranded, Concentric-Lay Aluminum 1350 Series Conductors with Steel Support Center Wire(s) per ASTM B232 Assembly ACSR bare overhead supporting neutrals are concentric-lay-stranded conductors with a single steel core wire or stranded steel core wires surrounded by one or more layers of helically applied aluminum alloy 1350 wires. Outer layer has right-handed lay. APPLICATIONS Suitable for overhead transmission and distribution applications that require rated strengths for steel support. Encore's ACSR overhead neutrals include Class AA for bare conductors commonly used in overhead lines, and/or Class A for conductors to be covered with weather-resistant materials. Please inquire about availability on sizes and constructions not listed below. ➊ ➊Aluminum Coated Steel Reinforced (ACSR), 1350 Series Alloy ➋Steel Support Center Wire ➋ ACSR BARE OVERHEAD SERVICE DROP NEUTRAL ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED - 1350 SERIES ALLOY WITH STEEL SUPPORT CENTER WIRE Conductor Sizes Nominal Diameters Strands Code Name KCMIL AWG (Alum/Stl) Class Turkey Swan Swanate Sparrow Sparate Robin Raven Quail Pigeon Penguin Waxwing Merlin Chickadee Pelican Osprey Kingbird Coot Skylark 26.24 41.40 41.74 66.36 66.36 83.69 105.60 133.10 167.80 211.60 266.80 336.40 397.50 477.00 556.20 636.00 795.00 1272.00 6 4 4 2 2 1 1/0 2/0 3/0 4/0 - 6/1 6/1 7/1 6/1 7/1 6/1 6/1 6/1 6/1 6/1 18/1 18/1 18/1 18/1 18/1 18/1 36/1 36/1 AA, A AA, A AA, A AA, A AA, A AA, A AA, A AA, A AA, A AA, A AA AA AA AA AA AA AA AA Alum Diam Steel Diam 0.0661 0.0834 0.0772 0.1052 0.0974 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.1367 0.1486 0.1628 0.1758 0.1880 0.1486 0.1880 0.0661 0.0834 0.1029 0.1052 0.1299 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.1367 0.1486 0.1628 0.1758 0.1880 0.1486 0.1880 Content % of Weight Finished Alum Steel OD % % 0.198 0.250 0.257 0.316 0.325 0.354 0.398 0.447 0.502 0.563 0.609 0.684 0.743 0.814 0.879 0.940 1.040 1.316 67.8 67.9 58.2 67.9 58.1 67.9 67.9 67.9 67.9 67.9 86.4 86.4 86.4 86.4 86.4 86.4 92.7 92.7 32.2 32.1 41.8 32.1 41.9 32.1 32.1 32.1 32.1 32.1 13.6 13.6 13.6 13.6 13.6 13.6 7.3 7.3 Approximate Rated Net Weight Strength (lbs/1000 ft) (lbs) 36 57 67 91 107 115 145 183 231 291 289 365 431 517 603 690 804 1286 1190 1860 2360 2850 3640 3550 4380 5300 6620 8350 6880 8700 9900 11800 13700 15700 16800 26400 Resistance DC Resistance at 20C AC Resistance at 60 Hz (Ohms/1000 ft) Reactance 25°C / @ 60 Hz 1ft. equiv. spacing (Megohms/1000 ft) DC 20°C AC 25°C AC 50°C AC 50°C Capacitive Inductive Ampacity (amps) 0.642 0.403 0.399 0.253 0.251 0.201 0.159 0.127 0.100 0.080 0.0644 0.0510 0.0432 0.0360 0.0309 0.0269 0.0217 0.0135 0.655 0.412 0.407 0.259 0.256 0.206 0.163 0.130 0.103 0.082 0.0657 0.0523 0.0443 0.0369 0.0318 0.0278 0.0225 0.0145 0.750 0.479 0.463 0.308 0.297 0.247 0.197 0.162 0.121 0.107 0.0723 0.0574 0.0487 0.0405 0.0348 0.0306 0.0247 0.0159 0.816 0.522 0.517 0.336 0.330 0.270 0.216 0.176 0.145 0.116 0.0788 0.0625 0.0528 0.0441 0.0379 0.0332 0.0268 0.0173 0.751 0.715 0.710 0.679 0.674 0.660 0.642 0.624 0.606 0.597 0.576 0.560 0.544 0.528 0.518 0.507 0.492 0.455 0.1201 0.1152 0.1153 0.1100 0.1081 0.1068 0.1040 0.1017 0.0992 0.0964 0.0934 0.0877 0.0856 0.0835 0.0818 0.0805 0.0780 0.0720 105 140 140 185 185 210 240 275 315 365 445 515 575 640 710 773 884 1084 DC Resistance based on 16.95 Ohms-cmil/ft (20°C); 61.20% IACS for EC-1350; 8% of ACS for steel AC Resistance at 60Hz Ampacity based on 75°C conductor temp; 25°C ambient temp; 0.5 coefficients emissivity and absorption; 2ft./sec wind; 96 watts /sq. ft sun 50 800.962.9473 www.encorewire.com TYPE duplex - EC-1350 SERIES ALUMINUM - overhead service DROP - 600V ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED supporting neutral Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductor: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Duplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C wet or dry. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Duplex overhead service drop cable has one black XLPE insulated aluminum conductor cabled around a bare stranded ACSR 1350 Series alloy supporting neutral with steel support center wire. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation wet or dry. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductor is surface printed for identification. ➊ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Aluminum Conductor Steel Reinforced Supporting Neutral (ACSR), ➋ EC-1350 Series ➍Steel Support Center Wire ➍ ➌ TYPE DUPLEX- EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) Shepard Terrier Chow Bull 6-6 4-4 2-2 1/0-1/0 Bare Neutral Conductor Insulation Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) 6 4 2 1/0 7 7 7 10 0.045 0.045 0.045 0.060 0.259 0.303 0.358 0.456 Type Size (AWG) ACSR ACSR ACSR ACSR 6 4 2 1/0 Diameter of Final Approximate Rated Finished *Ampacity Construction Net Weight No. of Strength OD (XLPE) (in) (lbs/1000 ft) Strands (lbs) (in) 6+1 6+1 6+1 6+1 1190 1860 2850 4380 0.198 0.250 0.316 0.398 110 145 195 260 0.457 0.553 0.674 0.854 75 110 180 280 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 800.962.9473 www.encorewire.com 51 TYPE TRIplex - EC-1350 SERIES aluminum - overhead service DROP - 600V ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED supporting neutral Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductors: Compact Stranded Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C wet or dry. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare stranded ACSR 1350 Series alloy supporting neutral with steel support center wire. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation wet or dry. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductors are surface printed for identification. ➌ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Aluminum Conductor Steel Reinforced Supporting Neutral (ACSR), ➍ EC-1350 Series ➍Steel Support Center Wire ➋ ➊ TYPE TRIPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) Voluta Strombus Periwinkle Cockle Conch Janthina Clio Neritina Runcina Aega Mursia Cerapsus Zuzara 6-6-6 4-4-6 4-4-4 2-2-4 2-2-2 1/0-1/0-2 2/0-2/0-1 1/0-1/0-1/0 2/0-2/0-2/0 3/0-3/0-1/0 3/0-3/0-3/0 4/0-4/0-2/0 4/0-4/0-4/0 Bare Neutral Conductor XLPE Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) 6 4 4 2 2 1/0 2/0 1/0 2/0 3/0 3/0 4/0 4/0 7 7 7 7 7 10 12 10 12 15 15 19 19 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.060 0.060 0.060 0.259 0.303 0.303 0.358 0.358 0.456 0.496 0.456 0.496 0.543 0.543 0.595 0.595 Type Size (AWG) ACSR ACSR ACSR ACSR ACSR ACSR ACSR ACSR ACSR ACSR ACSR ACSR ACSR 6 6 4 4 2 2 1 1/0 2/0 1/0 3/0 2/0 4/0 Diameter of Final Approximate Rated Finished *Ampacity Construction Net Weight No. of Strength OD (XLPE) (in) (lbs/1000 ft) Strands (lbs) (in) 6+1 6+1 6+1 6+1 6+1 6+1 6+1 6+1 6+1 6+1 6+1 6+1 6+1 1190 1190 1860 1860 2850 2850 3550 4380 5300 4380 6620 5300 8350 0.198 0.198 0.250 0.250 0.316 0.316 0.354 0.398 0.447 0.398 0.502 0.447 0.563 110 115 115 150 150 200 230 200 230 350 350 405 405 0.558 0.648 0.653 0.761 0.771 0.967 1.052 0.980 1.066 1.151 1.167 1.261 1.279 105 160 175 230 270 375 450 430 520 560 645 690 800 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 52 800.962.9473 www.encorewire.com TYPE QUADRUPLEx - EC-1350 SERIES Aluminum - overhead service DROP - 600V ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED SUPPORTING NEUTRAL Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductors: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Quadruplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C wet or dry. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Quadruplex overhead service drop cable has three black XLPE insulated aluminum conductors cabled around a bare stranded ACSR 1350 Series alloy supporting neutral with steel support center wire. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation wet or dry. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductors are surface printed for identification. ➌ ➍ ➊XLPE Insulation ➋Compact Stranded Conductor EC-1350 Series ➌ Aluminum Conductor Steel Reinforced Supporting Neutral (ACSR), EC-1350 Series ➍Steel Support Center Wire ➋ ➊ TYPE QUADRUPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V ACSR - ALUMINUM CONDUCTOR STEEL REINFORCED SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) XLPE Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) Bare Neutral Conductor Type Chola 6-6-6-6 6 7 0.045 0.259 ACSR Hackney 4-4-4-4 4 7 0.045 0.303 ACSR Palomino 2-2-2-2 2 7 0.045 0.358 ACSR Costena 1/0-1/0-1/0-1/0 1/0 10 0.060 0.456 ACSR Grullo 2/0-2/0-2/0-2/0 2/0 12 0.060 0.496 ACSR Suffolk 3/0-3/0-3/0-3/0 3/0 15 0.060 0.543 ACSR Appaloosa 4/0-4/0-4/0-4/0 4/0 19 0.060 0.595 ACSR *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Size (AWG) 6 4 2 1/0 2/0 3/0 4/0 Rated Finished No. of Strength OD Strands (lbs) (in) 6+1 6+1 6+1 6+1 6+1 6+1 6+1 1190 1860 2850 4380 5300 6620 8350 0.198 0.250 0.316 0.398 0.447 0.502 0.563 Diameter of Final Approximate Ampacity Construction Net Weight (XLPE) (in) (lbs/1000 ft) 105 135 175 240 280 325 375 0.623 0.729 0.861 1.097 1.193 1.306 1.431 150 215 350 560 690 850 1060 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 800.962.9473 www.encorewire.com 53 AAAC BARE OVERHEAD SUPPORTING NEUTRAL AAAC - ALL ALUMINUM ALLOY CONDUCTOR - 6201 ALLOY Engineering Specifications: Standards: ASTM B398: Standard Specification for Aluminum-Alloy 6201-T81 Wire for Electrical Purposes. ASTM B399: Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors. Construction: Conductors: Stranded, Concentric-Lay Aluminum Alloy 6201 Conductors per ASTM B399. Assembly: AAAC bare overhead supporting neutrals are concentric-lay-stranded aluminum alloy 6201-T81 conductors in one or more layers wrapped helically around a central core. Outer layer has right-handed lay. Applications: Suitable for overhead transmission and distribution applications that require rated strengths for 6201 alloy at a T81 temper. Encore's AAAC overhead neutrals include Class AA for bare conductors usually used in overhead lines, and/or Class A for conductors to be covered with weather-resistant materials. Please inquire about availability on sizes and constructions not listed below. ➊Concentric Stranded AAAC 6201 Alloy Supporting Neutral AAAC BARE OVERHEAD SUPPORTING NEUTRAL AAAC - ALL ALUMINUM ALLOY CONDUCTOR - 6201 ALLOY Nominal Diameters Conductor Sizes Code Word Akron Alton Ames Azusa Anaheim Amherst Alliance Butte Canton Cairo Darien Elgin Flint Greely Area KCMIL (mm²) 30.58 48.69 77.47 123.30 155.40 195.70 246.90 312.80 394.50 465.40 559.50 652.40 740.80 927.20 15.5 24.7 33.6 62.4 78.6 99.3 125.0 159.0 200.0 236.0 522.0 331.0 375.0 470.0 Area (in²) 0.0240 0.0382 0.0608 0.0968 0.1221 0.1537 0.1939 0.2456 0.3099 0.3655 0.4394 0.5124 0.5818 0.7282 No. of Strands Class 7 7 7 7 7 7 7 19 19 19 19 19 37 37 A A AA, A AA, A AA, A AA, A AA A AA, A AA AA AA AA AA Resistance DC Resistance at 20C AC Resistance at 60 Hz (Ohms/1000ft) AAC 1350 Cdr Size with Equivalent Each Finished Approximate Rated Net Weight Strength Resistance Strand OD (lbs/1000 ft) (lbs) (AWG/KCMIL) (in) (in) DC 20°C AC 25°C AC 50°C AC 50°C 0.0661 0.0834 0.1052 0.1327 0.1490 0.1672 0.1878 0.1283 0.1441 0.1565 0.1716 0.1853 0.1415 0.1583 0.6589 0.4138 0.2600 0.1635 0.1297 0.1030 0.0816 0.0644 0.0511 0.0433 0.0360 0.0309 0.0272 0.0217 0.6700 0.4200 0.2650 0.1660 0.1320 0.1050 0.0831 0.0657 0.0523 0.0443 0.0369 0.0318 0.0280 0.0225 0.7270 0.4560 0.2880 0.1800 0.1430 0.1140 0.0902 0.0712 0.0566 0.0481 0.0400 0.0345 0.0305 0.0244 0.7840 0.4920 0.3110 0.1950 0.1550 0.1230 0.0973 0.0769 0.0610 0.0517 0.0431 0.0371 0.0328 0.0263 0.198 0.250 0.316 0.396 0.447 0.502 0.563 0.642 0.721 0.783 0.858 0.927 0.991 1.108 29 45 72 115 145 183 230 292 368 434 522 608 691 865 1110 1760 2800 4270 5390 6790 8560 10500 13300 15600 18800 21900 24400 30500 6 4 2 1/0 2/0 3/0 4/0 266.80 336.40 397.50 477.00 556.50 636.00 795.00 Reactance 25°C / @ 60 Hz 1 ft. equiv. spacing (Megohms/1000ft) Capacitive Inductive 0.7510 0.7150 0.6780 0.6420 0.6240 0.6060 0.5880 0.5670 0.5490 0.5360 0.5220 0.5100 0.4990 0.4820 0.1180 0.1120 0.1070 0.1020 0.0989 0.0963 0.0936 0.0896 0.0870 0.0851 0.0829 0.0812 0.0793 0.0768 DC Resistance based on 19.76 Ohms-cmil/ft (20°C); 52.5% IACS. AC Resistance at 60Hz. Ampacity based on 75°C conductor temp; 25°C ambient temp; 0.5 coefficients emissivity and absorption; 2ft./sec wind in sun. 54 800.962.9473 www.encorewire.com Ampacity (Amps) 107 143 191 256 296 342 395 460 532 590 663 729 790 908 TYPE duplex - EC-1350 SERIES aLUMINUM - overhead service DROP - 600V AAAC - aluminum conductor 6201 alloy supporting NEUTRAL Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B399; ARRA 2009/FAR Subpart 25.6 “Buy American” Compliant. Construction: Conductors: Insulated Conductor: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded Aluminum 6201 Alloy Conductor (AAAC) Bare Supporting Neutral per ASTM B398; ASTM B399. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Duplex overhead service drop cable with bare stranded AAAC 6201 aluminum alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C wet or dry. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Duplex overhead service drop cable has one black XLPE insulated aluminum conductor cabled around a bare stranded AAAC 6201 aluminum alloy supporting neutral. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation wet or dry. Manufactured and tested according to ANSI/ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductor is surface printed for identification. ➊ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Concentric Stranded AAAC 6201 Alloy Supporting Neutral ➋ ➌ TYPE DUPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V AAAC - ALUMINUM CONDUCTOR 6201 ALLOY SUPPORTING NEUTRAL Phase Conductors Bare Neutral Conductor Conductor Insulation Outside Sizes Size No. of Thickness Diameter Code Word (AWG) (AWG) Strands (in) (in) Vizsla Whippet Schnauzer Heeler 6-6 4-4 2-2 1/0-1/0 6 4 2 1/0 7 7 7 10 0.045 0.045 0.045 0.060 0.259 0.303 0.358 0.456 Type 6201 6201 6201 6201 Size Size No. of (AWG) (KCMIL) Strands 6 4 2 1/0 30.58 48.69 77.47 123.3 7 7 7 7 Rated Strength (lbs) 1110 1760 2800 4270 Diameter of Final Approximate Finished *Ampacity Construction Net Weight OD (XLPE) (in) (lbs/1000 ft) (in) 0.198 0.250 0.316 0.398 110 145 195 260 0.462 0.558 0.679 0.864 68 102 156 249 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 800.962.9473 www.encorewire.com 55 TYPE TRIplex - EC-1350 SERIES aluminum - overhead service DROP - 600V AAAC - aluminum conductor 6201 alloy supporting neutral Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B399; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductors: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded Aluminum 6201 Alloy Conductor (AAAC) Bare Supporting Neutral per ASTM B398; ASTM B399. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Triplex overhead service drop cable with bare stranded AAAC 6201 aluminum alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C wet or dry. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare stranded AAAC 6201 aluminum alloy supporting neutral. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation wet or dry. Manufactured and tested according to ANSI/ICEA S-76-474: Stranded For Neutral/Supported Power Cable Assemblies With Weather-Resistant Extended Insulations Rated 600 Volts. Insulated conductors are surface printed for identification. ➌ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Concentric Stranded AAAC 6201 Alloy Supporting Neutral ➋ ➊ TYPE TRIPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V AAAC - ALUMINUM CONDUCTOR 6201 ALLOY SUPPORTING NEUTRAL Phase Conductors Bare Neutral Conductor Conductor Insulation Outside Sizes Size No. of Thickness Diameter Code Word (AWG) (AWG) Strands (in) (in) Type Hippa Crab Barnacles Solaster Shrimp Echinus Leda Dungenese Cyclops Fulgar Flustra Arca Lepas 6201 6201 6201 6201 6201 6201 6201 6201 6201 6201 6201 6201 6201 6-6-6 4-4-6 4-4-4 2-2-4 2-2-2 1/0-1/0-2 1/0-1/0-1/0 2/0-2/0-2/0 2/0-2/0-2/0 3/0-3/0-1/0 3/0-3/0-3/0 4/0-4/0-2/0 4/0-4/0-4/0 6 4 4 2 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 7 7 7 7 7 10 10 12 12 15 15 19 19 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.060 0.060 0.060 0.259 0.303 0.303 0.358 0.358 0.456 0.456 0.496 0.496 0.543 0.543 0.595 0.595 Diameter of Final Approximate Rated Finished *Ampacity Construction Net Weight Size Size No. of Strength OD (XLPE) (in) (lbs/1000 ft) (AWG) (KCMIL) Strands (lbs) (in) 6 6 4 4 2 2 1/0 2/0 2/0 1/0 3/0 2/0 4/0 30.58 30.58 48.69 48.69 77.47 77.47 123.3 155.4 155.4 123.3 195.7 155.4 246.9 7 7 7 7 7 7 7 7 7 7 7 7 7 1110 1110 1760 1760 2800 2800 4280 5390 5390 4280 6790 5390 8560 0.198 0.198 0.250 0.250 0.316 0.316 0.398 0.447 0.447 0.398 0.502 0.447 0.563 110 145 145 195 195 260 260 300 300 350 350 405 405 0.581 0.678 0.678 0.797 0.797 1.009 1.009 1.097 1.097 1.197 1.197 1.313 1.313 106 140 157 210 237 338 381 469 469 513 581 633 719 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 56 800.962.9473 www.encorewire.com TYPE QUADRUPLEX - ec-1350 Series aluminum - overhead service DROP - 600v AAAC - ALUMINUM CONDUCTOR 6201 ALLOY SUPPORTING NEUTRAL Engineering Specifications: Standards: ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B399; ARRA 2009 Section 1605 “Buy American” Compliant. Construction: Conductors: Insulated Conductors: Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836. Neutral Conductor: Stranded Aluminum 6201 Alloy Conductor (AAAC) Bare Supporting Neutral per ASTM B398; ASTM B399. Insulation: Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90°C wet or dry. Applications: Quadruplex overhead service drop cable with bare stranded AAAC 6201 aluminum alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90°C wet or dry. Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure. Suitable for 120 volt aerial service for outdoor lighting or for temporary service at construction sites. Features: Quadruplex overhead service drop cable has three black XLPE insulated aluminum conductors cabled around a bare stranded AAAC 6201 aluminum alloy supporting neutral. Superior weather-, abrasion-, crush-, and sunlight-resistant XLPE insulation rated 90°C operation wet or dry. Manufactured and tested according to ANSI/ ICEA S-76-474: Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts. Insulated conductors are surface printed for identification. ➌ ➊XLPE Insulation ➋Compact Stranded Conductor, EC-1350 Series ➌Concentric Stranded AAAC 6201 Alloy Supporting Neutral ➋ ➊ TYPE QUADRUPLEX - EC-1350 SERIES ALUMINUM - OVERHEAD SERVICE DROP - 600V AAAC - ALUMINUM CONDUCTOR 6201 ALLOY SUPPORTING NEUTRAL Phase Conductors Code Word Conductor Sizes (AWG) French-Coat Arabian Belgian Shetland Thoroughbred Trotter Walking 6-6-6-6 4-4-4-4 2-2-2-2 1/0-1/0-1/0-1/0 2/0-2/0-2/0-2/0 3/0-3/0-3/0-3/0 4/0-4/0-4/0-4/0 Bare Neutral Conductor Insulation Outside Size No. of Thickness Diameter (AWG) Strands (in) (in) 6 4 2 1/0 2/0 3/0 4/0 7 7 7 10 12 15 19 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.259 0.303 0.358 0.456 0.496 0.543 0.595 Type 6201 6201 6201 6201 6201 6201 6201 Size Size No. of (AWG) (KCMIL) Strands 6 4 2 1/0 2/0 3/0 4/0 30.58 48.69 77.47 123.3 155.4 195.7 246.9 7 7 7 7 7 7 7 Rated Strength (lbs) 1110 1760 2800 4270 5390 6790 8560 Diameter of Final Approximate Finished *Ampacity Construction Net Weight OD (XLPE) (in) (lbs/1000 ft) (in) 0.169 0.213 0.268 0.336 0.376 0.423 0.475 105 135 175 240 280 325 375 0.635 0.745 0.886 1.113 1.212 1.323 1.448 140 210 330 515 640 790 970 Standard Packaging Reels (ft) 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' 500' 1000' 1500' *Ampacities shown are for non-NEC applications and are based on the following factors: a) conductor temperature of 65°C over 25°C ambient temperature b) 2 ft./sec crosswind c) .9 coefficient of emissivity, no sun For NEC® type applications, consult appropriate NEC ampacity section. The above data is approximate and subject to normal manufacturing tolerances. Print Legend: ENCORE WIRE CORP (SIZE) AWG EC-1350 AL CDR XLPE SUN RES 600 VOLT DATE/TIME/OPERATOR/QC 800.962.9473 www.encorewire.com 57
Similar documents
Overhead Line Conductors
The current rating mentioned above is based on ambient temp. of 50° C and max. conductor temp. of 80° C.
More informationBare Overhead Conductors
(AWG/kcmil) (ohm/kft) (ohm/kft) (ohm/kft) (ohm/kft) (megohm-kft) (ohm/kft) (ohm/kft)
More information