Válvulas Pilotadas Por Aire
Transcription
Válvulas Pilotadas Por Aire
Desde1963 Válvulas Pilotadas Proveedor Integral de Soluciones para Por Aire la Industria Válvulas angulares 290/ 390 La mejor en su tipo, ideal para manejo de agua caliente, vapor y fluidos viscosos o con sólidos en suspensión, fabricados en cuerpos de acero Inoxidable 316L y Bronce. 4 8290 SERIES | Angle Body Piston Valves Broad range of pressure operated valves for air, water, steam, and light slurries Bronze & stainless steel constructions Sizes 3/8" through 2 1/2" w w w. a s c o v a l v e . c o m 4 SERIES | 8290 4 8290 SERIES ...tough and packed with features POSITION MONITORING (OPTIONAL) • • • • Signaling box with dual mechanical or inductive contacts (shown) Compact signaling unit for magnetic position detectors Linear position indicator (HS4 Series) 50mm NC & 63mm through 125mm NC and NO STANDARD VISUAL POSITION INDICATOR With clear polypropylene cover on 63mm through 125mm (optional on 32mm & 50mm). PISTON ACTUATOR Rotates 360˚ to allow easy assembly and positioning of pilot port. ASCO PILOT VALVES The industry standard for reliability and durability in all industrial environments. (See back cover) RUGGED WATERTIGHT ACTUATOR Made from tough fiber composite and protected with double o-ring seal. ONE PIECE COLD ROLLED S.S. STEM RELIABILITY Smooth stem movements guided by two oversized bearings. Provides added strength and less resistance. SPRING LOADED STEM SEAL The FKM flouroelastomer wiper keeps harmful grit away from the stem area. As a backup, there are multiple-ribbed shearing rings that provide a cleaning action in the stem grooves. These rings provide a longer life by preventing debris from reaching the chevron packing. STUFFING BOX Externally sealed using a flat embedded seal ring. HIGH FLOW RATE Optimization of the fluid flow path. PTFE DISC SEAL For bubble tight shutoff. 2 ANTI-WATER HAMMER The fluid passes under the disc resulting in slower closure. 4 SERIES | 8290 The 8290 Angle Body Piston Valve is a 2-way direct acting valve available in a normally closed or normally open construction. They have proven durability in handling aggressive fluids, such as steam, hot water, solvents, and light slurries. The 8290 Series is pressure operated with a straight-through design available with bronze or stainless steel bodies built for demanding applications. There are many optional features including position indication and proportional control. 8290 SERIES | ASSEMBLY CONFIGURATOR ASCO has simplified the 8290 selection process and added the ability to create assemblies using pilot valves and position indicators. After you have determined your product requirements, you can easily construct a catalog number by clicking on each feature required and clicking on the View Details button. A second screen will then appear providing the product catalog number, product specification, and various drawings. You can also enter an existing catalog number that the configurator has created before to decipher the specifications of the catalog number. Type the configured catalog number into the text box next to the Enter Catalog Number button (CAPs only). The configurator will automatically highlight the corresponding features of the product. In order to use the online configurator go to: www.ascovalve.com/8290Configurator 3 4 SERIES | 8290 Angle Body Multi-Purpose Valves Air or Water Pilot Operated Bronze or 316L Stainless Steel Bodies • 3/8" to 2 1/2" NPT The 8290 Series consists of 2-way direct acting valves available in normally closed or normally open constructions. Built for demanding applications, these valves come in a straight-through body design made of bronze or stainless steel. There are many optional features including visual/electrical position indicator or a stroke limiter. The 8290 Series is suitable for the following applications: • General Service (air, inert gas, water, oil, light slurries) • Steam and Hot Water Construction Valve Parts in Contact with Fluids 32mm 50mm-125mm Part 50mm-125mm Body 316L Stainless Steel Bronze 316L Stainless Steel Stem 316L Stainless Steel 431 Stainless Steel 431 Stainless Steel Stuffing Box 316L Stainless Steel Brass 303 Stainless Steel Stuffing Box Seal PTFE PTFE Chevron PTFE Chevron Wiper Seal FKM FKM FKM 316L Stainless Steel Brass 304L Stainless Steel PTFE PTFE PTFE 316L Stainless Steel - - Disc Disc Seal Screw For all optional AISI 316L Stainless Steel constructions, contact ASCO Specifications Ambient Temperature Range: 15˚F to 140˚F (32˚F to 122˚F for proportional and water service) Pilot Fluid Temperature Range: 15˚F to 140˚F (32˚F to 122˚F for proportional and water service) Maximum Viscosity: 2,700 SSU For higher viscosity applications, please consult ASCO. Alternate Valve Constructions • Oxygen service, add suffix "N". • Medium vacuum service up to 7 x 10-3 Torr, add suffix "VM". • Visual Position Indicator for normally closed valve with 32mm or 50mm operator, add suffix “VI” (note: position indicator standard on 63mm through 125mm operators). • NET-INOX treatment (stainless steel valve body pickled in nitric/hydrofluoric acid bath), add suffix “NI”. See inside back cover for the following constructions: • Signaling Box • Compact Positioners for proportional control • Linear Position Indicator • Stroke Limiter Visit www.ascovalve.com/8290Configurator to create an 8290 assembly that fits your needs. Options include position indication, pilot valves, and other accessories. 4 1 NC 2 NO 4 SERIES | 8290 Specifications Operating Pressure Differential (psi) Pipe Size (in) Orifice Size (in) Cv Flow On-Off Prop. Normally Closed - Entry Under the Disc 3/8 3/8 2.3 - Max. Max. Min. Fluids Steam Max. Fluid Temp.°F 32 mm Operator Air or Water Pilot Pressure (psi) Bronze Stainless Steel Min. Max. Approx. Shipping Weight (lbs.) 0 240 150 366 - 8290A791 60 150 1.3 1/2 1/2 4.1 - 0 180 150 366 - 8290A792 60 150 1.4 3/4 3/4 7.6 - 0 90 90 366 - 8290A793 60 150 1.6 Normally Open - Entry Under the Disc 3/8 3/8 2.3 - 0 240 150 366 - 8290A794 I 150 1.3 1/2 1/2 4.1 - 0 240 150 366 - 8290A795 I 150 1.4 3/4 3/4 7.6 - 0 200 150 366 - 8290A796 I 150 1.6 Normally Closed - Entry Above the Disc for Rapid Cycling Steam Applications 3/8 3/8 2.3 - 0 - 150 366 - 8290A797 II 150 1.6 1/2 1/2 4.1 - 0 - 150 366 - 8290A798 II 150 1.4 3/4 3/4 7.6 - 0 - 150 366 - 8290A799 II 150 1.6 50 mm Operator Normally Closed - Entry Under the Disc 1/2 1/2 5.7 5.3 0 240 150 366 8290A384 8290A393 60 150 2.7 3/4 3/4 11 8.3 0 150 150 366 8290A385 8290A394 60 150 2.9 1 1 15 - 0 90 90 366 8290A386 8290A395 60 150 3.7 Normally Open - Entry Under the Disc 1/2 1/2 5.7 - 0 240 150 366 8290A387 8290A396 III 150 2.7 3/4 3/4 11 - 0 240 150 366 8290A388 8290A397 III 150 2.9 1 1 15 - 0 240 150 366 8290A389 8290A398 III 150 3.7 Normally Closed - Entry Above the Disc for Rapid Cycling Steam Applications 1/2 1/2 5.7 0 150 366 8290A390 8290A399 IV 150 2.7 3/4 3/4 11 - 0 - 150 366 8290A391 8290A400 IV 150 2.9 1 1 15 - 0 - 150 366 8290A392 8290A401 IV 150 3.7 63 mm Operator Normally Closed - Entry Under the Disc 1/2 1/2 5.7 - 0 240 150 366 8290B002 8290B045 38 150 3.6 3/4 3/4 11 8.3 0 240 150 366 8290B005 8290B048 60 150 3.9 1 1 19 17 0 150 150 366 8290B010 8290B053 60 150 4.7 1 1/4 1 1/4 32 24 0 90 90 366 8290A016 8290A059 60 150 6.0 1 1/2 1 1/2 52 33 0 60 60 366 8290A020 8290A063 60 150 8.0 2 2 68 46 0 40 40 366 8290A024 8290A067 60 150 10.0 Normally Open - Entry Under the Disc 1/2 1/2 5.7 - 0 240 150 366 8290B026 8290B069 V 150 3.6 3/4 3/4 11 - 0 240 150 366 8290B027 8290B070 V 150 3.9 1 1 19 - 0 240 150 366 8290B028 8290B071 V 150 4.7 1 1/4 1 1/4 32 - 0 240 150 366 8290A030 8290A073 V 150 6.0 1 1/2 1 1/2 52 - 0 160 150 366 8290A032 8290A075 V 150 8.0 2 2 68 - 0 105 105 366 8290A034 8290A077 V 150 10.0 Normally Closed - Entry Above the Disc for Rapid Cycling Steam Applications 1/2 1/2 5.7 - 0 - 150 366 8290B036 8290B079 VI 150 3.6 3/4 3/4 11 - 0 - 150 366 8290B037 8290B080 VI 150 3.9 1 1 19 - 0 - 150 366 8290B038 8290B081 VI 150 4.7 1 1/4 1 1/4 32 - 0 - 150 366 8290A039 8290A082 VI 150 6.0 1 1/2 1 1/2 52 - 0 - 150 366 8290A040 8290A083 VI 150 8.0 2 2 68 - 0 - 135 366 8290A042 8290A085 VI 150 10.0 Available with NET-INOX treatment, add suffix "NI"; Minimum pilot pressure varies, see identified graph for appropriate values; For Visual Position Indicator add suffix "VI". 5 4 SERIES | 8290 Specifications Pipe Size (in) Orifice Size (in) Operating Pressure Differential (psi) Cv Flow On-Off Max. Prop. Min. Fluids Max. Fluid Temp.°F Steam 90 mm Operator Normally Closed - Entry Under the Disc 1 1 19 17 0 240 1 1/4 1 1/4 32 24 0 180 1 1/2 1 1/2 52 33 0 120 2 2 68 46 0 90 Normally Open - Entry Under the Disc 1 1 19 0 240 1 1/4 1 1/4 32 0 240 1 1/2 1 1/2 52 0 240 2 2 68 0 200 Normally Closed - Entry Above the Disc for Rapid Cycling Steam Applications 1 1/4 1 1/4 32 0 1 1/2 1 1/2 52 0 2 2 68 0 Normally Closed - Entry Under the Disc 1 1/4 1 1/4 34 1 1/2 1 1/2 56 2 2 77 2 1/2 2 1/2 130 Normally Open - Entry Under the Disc 1 1/4 1 1/4 34 1 1/2 1 1/2 56 2 2 77 2 1/2 2 1/2 130 Air or Water Pilot Pressure (psi) Bronze Stainless Steel Min. Max. Approx. Shipping Weight (lbs.) 150 150 120 90 366 366 366 366 8290B011 8290A017 8290A021 8290A025 8290B054 8290A060 8290A064 8290A068 60 60 60 60 150 150 150 150 6.5 7.7 9.5 16.0 150 150 150 150 366 366 366 366 8290B029 8290A031 8290A033 8290A035 8290B072 8290A074 8290A076 8290A078 VII VII VII VII 150 150 150 150 6.5 7.7 9.5 16.0 150 366 150 366 150 366 125 mm Operator 8290A136 8290A041 8290A043 8290A137 8290A084 8290A086 VIII VIII VIII 150 150 150 7.7 9.5 16.0 34 56 77 86 0 0 0 0 240 240 150 90 150 150 150 90 366 366 366 366 8290A642 8290A482 8290A485 8290A488 8290A646 8290A495 8290A498 8290A501 60 60 60 60 150 150 150 150 13.5 15.0 17.0 21.5 - 0 0 0 0 240 240 240 240 150 150 150 150 366 366 366 366 8290A643 8290A489 8290A490 8290A492 8290A647 8290A502 8290A503 8290A505 IX IX IX IX 150 150 150 150 13.5 15.0 17.0 21.5 Available with NET-INOX treatment, add suffix "NI"; Minimum pilot pressure varies, see identified graph for appropriate values. Dimensions: inches 32 mm Operator Graphs for Steam and Fluids 32 mm Operator B C D E ØF 3.62 3.66 3.21 2.17 0.93 3.90 3.82 3.29 2.56 1.10 4.21 4.11 3.46 2.95 1.26 Normally Open Valve - Entry Under Disc Normally Closed Valve - Entry Above Disc 150 150 Min. Pilot Pressure (psi) Min. Pilot Pressure (psi) in in in ØA 3/8 1/2 3/4 3/4 120 90 1/2 3/8 60 30 I 0 60 120 180 120 90 3/4 3/8,1/2 60 30 II 0 240 30 60 90 120 150 Differential Pressure ∆p (psi) Differential Pressure ∆p (psi) Normally Closed Normally Open é 1.7 Ø 1.7 1/8 FILTER PLUG 0Ê ˚ 60 36 3 ØF 6 B Ê 1. 50 ˚ 50 ØA 7 C D C D 1/8 E éA éF B E 4 SERIES | 8290 Dimensions: inches 50 mm Operator Graphs for Steam and Fluids Normally Closed Valve - Entry Above Disc Normally Open Valve - Entry Under Disc 150 Min. Pilot Pressure (psi) Min. Pilot Pressure (psi) 150 120 1 90 3/4 1/2 60 30 120 90 1 3/4 1/2 60 30 III 0 120 60 180 IV 0 240 Differential Pressure ∅P (psi) 90 120 150 Normally Open F 1.06 1.26 1.61 Ø 2.7 1/8 FILTER PLUG 0˚ 36 ˚ 50 ØA F B E Normally Closed Ø 2.7 0˚ 36 1/8 7 1. 50 ˚ E 2.56 2.95 3.54 C D 50 mm Operator B C D 5.59 6.08 5.55 5.92 6.26 5.63 6.10 6.50 5.71 60 C D in in in ØA 1/2 3/4 1 30 Differential Pressure ∅P (psi) ØA F B E 7 4 SERIES | 8290 Dimensions: inches 63 mm Operator Graphs for Steam and Fluids Normally Open Valve - Entry Under Disc 2 150 1 1/4 Min. Pilot Pressure (psi) Min. Pilot Pressure (psi) 1 1/2 2 150 Normally Closed Valve - Entry Above Disc 120 1 90 3/4 1/2 60 30 120 1 1/2 90 1 1/4 1 3/4 1/2 60 30 V 0 60 120 180 VI 0 240 Differential Pressure ∅P (psi) 63 mm Operator B C D 6.70 7.20 6.60 6.80 7.30 6.70 7.20 7.70 6.90 8.54 9.01 8.03 8.82 9.64 8.46 9.80 10.20 8.82 60 90 120 150 Normally Open E 2.56 2.95 3.54 4.33 4.72 5.90 F 1.06 1.26 1.61 1.97 2.36 2.76 Ø 3.4 FILTER PLUG 0˚ 1/8 36 C D in in in in in in ØA 1/2 3/4 1 1 1/4 1 1/2 2 30 Differential Pressure ∅P (psi) 0 50 ˚ 2. ØA F E B Normally Closed Ø 3.4 FILTER PLUG 1/8 0˚ C D 36 0 50 ˚ 2. ØA 8 F B E 4 SERIES | 8290 Dimensions: inches 90 mm Operator Graphs for Steam and Fluids Normally Open Valve - Entry Under Disc 2 150 Min. Pilot Pressure (psi) 150 Min. Pilot Pressure (psi) Normally Closed Valve - Entry Above Disc 120 1-1/2 90 1-1/4 60 1 30 0 120 120 180 2 1-1/2 60 1-1/4 30 VII 60 90 VIII 0 240 Differential Pressure ∅P (psi) 60 90 120 150 Differential Pressure ∅P (psi) Normally Open F 1.61 1.97 2.36 2.76 Ø 4.7 FILTER PLUG 0˚ 1/4 36 6 2. 50 ˚ C D ØA F E B Normally Closed Ø 4.7 FILTER PLUG 1/4 0˚ 36 6 2. ˚ 50 E 3.54 4.33 4.72 5.91 C D in in in in 90 mm Operator ØA B C D 1 8.00 8.50 7.70 1 1/4 9.29 9.69 8.70 1 1/2 9.57 10.31 9.13 2 10.51 10.87 9.49 30 ØA F B E 9 4 SERIES | 8290 Dimensions: inches 125 mm Operator Graphs for Steam and Fluids Normally Open Valve - Entry Under Disc Min. Pilot Pressure (psi) 150 120 2 1/2 90 2 60 1 1/2 1 1/4 30 IX 0 60 120 180 240 Differential Pressure ∅P (psi) ØA B 125 mm Operator C D E in 1 1/4 11.10 11.70 10.70 4.30 G H 3.10 2.00 in 1 1/2 11.50 12.30 11.20 4.70 3.10 2.40 in 12.40 12.90 11.50 6.00 3.10 2.80 in 2 1/2 13.70 13.90 12.10 7.50 3.10 3.10 2 Normally Open Ø 6.1 FILTER PLUG 0˚ 1/4 C D 36 50 ˚ G ØA H E B Normally Closed Ø 6.1 FILTER PLUG 1/4 0˚ 36 50 ˚ C D G ØA 10 H B E 4 SERIES | 8290 8290 SERIES | ACCESSORIES Signaling Box Supplied with two mechanical or inductive switches with LEDs and mounts on top of the valve operator in place of the standard visual indicator. As the valve cycles, cams on the signaling box lengthening stem operate the switches to provide electrical signaling of the valve position. The signaling box can rotate 360˚. Switches Add Suffix Two Mechanical SM2 Assembly available on 50mm normally closed and Two Inductive SI2 63mm through 125mm normally open and normally Two Intrinsically Safe SH2 closed. (e.g., 8290A384SM2) Compact Positioners for Proportional Control Varies flow proportional to a 0-10 VDC, 0-20 mA or 4-20 mA control signal. Feedback of valve stem position via a linear potentiometer. Uses a profiled disc for flow characterization. Assembly available on 50mm through 125mm operators, normally Control Signal Add Suffix 0-10 VDC PDB04 closed with fluid entry under disc. Positioner not suitable 0-20 mA PDB05 for water piloting. (e.g., 8290A384PDB04) 4-20 mA PDB06 Stroke Limiter The stroke limiter allows Cv flow to be adjusted from 0% to 100%, and mounts on top of the 8290 Series valve in place of the position indicator. Assembly available onto 50mm (normally closed) and 63mm through 125mm normally open or normally closed valves with fluid entry under the disc. Add suffix M: (e.g., 8290B002M) Linear Position Indicator (HS4 Series) Supplied with two mechanical switches and mounts on top of the valve operator in place of the standard visual indicator. Provides a wiring box with 1/2" NPT conduit connections. The HS4 linear position indicator is Type 4, 4X and IP 66 suitable for indoor and outdoor use in non-hazardous locations. Switches Two (2) Mechanical SPDT Gold (IS) Switches Two (2) Mechanical SPDT Silver (15A) Switches Part Number HS4D1YCH2NGA HS4D1YCA2NGA Pilot Valves ASCO offers a variety of 3-way direct acting normally closed pilot valves to pilot 32mm through 125mm 8290 valves. Available in direct, in-line, and remote mounting. To order, specify catalog number and voltage: 24, 120, 240 AC/60Hz or 110, 220 AC/50Hz or 6, 12, 24, 120/DC Series 189 Series 8320 Numatics® G3 • Direct mount • Swivel “Banjo” fittings, 1/8" NPT male • Inlet for 4mm plastic tube • DIN plug connection • • • • • Remote mount • 4 to 16 valves • Compatible with AS-interface®, DeviceNet™, Profibus® DP, FOUNDATION Fieldbus™, and others • Air service only In-line mount 1/8" or 1/4" NPT Brass or stainless steel (Explosionproof optional, add prefix EF) AS-interface is a registered trademark of AS-International. DeviceNet is a trademark of ODVA. Profibus is a registered trademark of Profibus International.FOUNDATION Fieldbus is a trademark of Fieldbus Foundation. 11 Global Contacts Australia Canada France Japan Singapore Tel (61) 2-9-451-7077 Tel (1) 519-758-2700 Tel (33) 1-47-14-32-00 Tel (81) 798-65-6361 Tel (65) 6556-1100 Brazil China Germany Mexico United Kingdom Tel (55) 11-4208-1700 Tel (86) 21-3395-0000 Tel (49)-7237-9960 Tel (52) 55-5809-5640 Tel (44) 1695-713600 ASCO Valve, Inc. | Tel (1) 800.972.2726 | www.ascovalve.com | e-mail: [email protected] 05/12 — V7393 R5 VALVES 2/2 E290 NC pressure operated bronze or stainless steel body threaded ports, 3/8 to 2 1/2 Series 1 NO 2 FEATURES • • • • High flow due to angled seat design Anti-waterhammer design (fluid entry under the disc) Vacuum operation up to 10-2 mbar Wide range of piston-type operators (32 - 50- 63 - 90 -125 mm dia.) rotatable through 360°, for maximum performance at different minimum pilot pressures • High performance, maintenance-free stuffing box • The valves satisfy Pressure Equipment Directive 97/23/EC, category 1 (DN > 25) or article 3.3 (DN ≤ 25) GENERAL Differential pressure Maximum allowable pressure Ambient temperature range Maximum viscosity Pilot fluid Max. pilot pressure Min. pilot pressure Pilot fluid temperature Response time See «SPECIFICATIONS» [1 bar =100 kPa] 16 bar -10°C to +60°C 5000 cSt (mm2/s) Filtered air or water (1) 10 bar See below and following page -10°C to +60°C See page V402-7 fluids (✴) temperature range disc seal (✴) DN ≤ 50: air and gas groups 1 & 2 DN 65: air and gas group 2 all DN: water, oil, liquids groups 1 & 2 and steam - 10°C to + 184°C PTFE D 1 MATERIALS IN CONTACT WITH FLUID 2 (✴) Ensure that the compatibility of the fluids in contact with the materials is verified Bronze body Stainless steel body Valve body Bronze AISI 316L Stuffing box housing Brass AISI 316L Stem Stainless steel Stainless steel Disc Brass Stainless steel Stuffing box packing PTFE chevrons PTFE chevrons Wiper seal FPM FPM Disc seal PTFE PTFE Valve body seal PTFE PTFE NC function, entry under the disc, 32 and 50 mm operators OTHER MATERIALS 1 Operator Optical position indicator (1) Glass fibre filled PA PA 12, supplied standard on valves with 63, 90 and 125 mm operators 2 For dia. 32, 50, 63, 90 and 125 mm operators: At service fluid temperatures inside the valve body above 100°C, it is prohibited to pilot the valve with water. NC function, entry under the disc, 63, 90 and 125 mm operators 00049GB-2011/R02 Availability, design and specifications are subject to change without notice. All rights reserved. SPECIFICATIONS piping (ISO 6708) pipe size DN flow coefficient Kv (m3/h) (l/min) (G*) pilot pressure (bar) min. operating pressure differential (bar) min. max. NC - Normally closed, entry under the disc 3/8 10 1/2 15 3/4 1 20 25 2,8 4,1 4,9 82 6,5 108 9,4 157 12,8 213 16,5 275 27 1 1/4 47 68 10 10 10 10 10 0 0 0 0 0 4 10 0 2,5 4 10 10 0 0 4 10 0 2,5 10 0 4 10 0 2,5 10 0 4 2,5 10 10 0 0 450 32 29 4 4 4 2,5 4 483 catalogue number operator diameter air, inert gas, aggressive fluids max. water, oil, liquids, aggressive liquids (✴) (✴) (✴) (≤184°C) (mm) 16 12 16 16 6 10 16 12 6 10 16 6 12 6 12 3 7 16 16 16 12 16 16 6 10 16 12 6 10 16 6 12 6 12 3 7 16 16 10 10 10 10 6 10 10 10 6 10 10 6 10 6 10 3 7 10 10 32 32 50 63 32 50 63 63 50 63 90 63 90 63 90 63 90 125 125 steam bronze stainless steel E290A384 E290B002 E290A385 E290B005 E290B004 E290A386 E290B010 E290B011 E290B008 E290B009 E290A016 E290A017 E290A014 E290A015 E290A642 E290A641 E290A791 E290A792 E290A393 E290B045 E290A793 E290A394 E290B048 E290B047 E290A395 E290B053 E290B054 E290B051 E290B052 E290A059 E290A060 E290A057 E290A058 E290A646 E290A645 (1) All leaflets are available on: www.asconumatics.eu V410-1 VALVES SERIES E290 SPECIFICATIONS piping (ISO 6708) pipe size DN flow coefficient Kv (m3/h) (l/min) (G*) pilot pressure (bar) min. operating pressure differential (bar) min. max. catalogue number operator diameter air, inert gas, aggressive fluids max. water, oil, liquids, aggressive liquids (✴) (✴) (✴) (≤184°C) (mm) 4 8 4 16 10 2,5 6 2,5 10 5 2 6 4 8 4 16 10 2,5 6 2,5 10 5 2 6 4 8 4 10 10 2,5 6 2,5 10 5 2 6 16 16 16 16 16 16 16 16 16 16 16 16 16 11 16 16 7 13 16 7 16 16 16 16 16 16 16 16 16 16 16 16 16 16 11 16 16 7 13 16 7 16 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 7 10 10 7 10 steam bronze stainless steel 63 90 90 125 125 63 90 90 125 125 90 125 E290A020 E290A021 E290A019 E290A482 E290A481 E290A024 E290A025 E290A023 E290A485 E290A484 E290A487 E290A488 E290A063 E290A064 E290A062 E290A495 E290A494 E290A067 E290A068 E290A066 E290A498 E290A500 E290A501 32 32 50 63 32 50 63 50 63 90 63 90 125 63 90 125 63 90 125 90 125 E290A387 E290B026 E290A388 E290B027 E290A389 E290B028 E290B029 E290A030 E290A031 E290A643 E290A032 E290A033 E290A489 E290A034 E290A035 E290A490 E290A491 E290A492 E290A794 E290A795 E290A396 E290B069 E290A796 E290A397 E290B070 E290B071 E290B072 E290A073 E290A074 E290A647 E290A075 E290A076 E290A502 E290A077 E290A078 E290A503 E290A504 E290A505 NC - Normally closed, entry under the disc (1) 45 1 1/2 2 2 1/2 750 40 48 800 59 983 66 1100 94 111 1567 1850 50 65 4 10 0 2,5 4 2,5 10 10 10 0 0 0 4 10 0 2,5 4 2,5 4 4 10 10 10 10 10 0 0 0 0 0 NO - Normally open, entry under the disc 3/8 10 1/2 15 3/4 20 1 25 1 1/4 32 1 1/2 40 2 50 2 1/2 65 2,8 4,1 47 68 4,9 82 6,5 108 9,4 157 12,8 213 16,5 275 27 450 29 483 45 750 48 800 59 983 66 94 111 1100 1567 1850 IX (✻) IX (✻) I (✻) II (✻) IX (✻) I (✻) II (✻) I (✻) II (✻) III (✻) II (✻) III (✻) IV (✻) II (✻) III (✻) IV (✻) II (✻) III (✻) IV (✻) III (✻) IV (✻) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3/8 10 1/2 15 3/4 20 2,8 4,1 47 68 4,9 82 6,5 108 9,4 157 213 275 1 25 12,8 16,5 1 1/4 32 27 450 1 1/2 40 45 750 2 50 59 983 65 94 111 1567 1850 2 1/2 X (✻) X (✻) V (✻) VI (✻) X (✻) V (✻) VI (✻) V (✻) VI (✻) VI (✻) VII (✻) VI (✻) VII (✻) VI (✻) VII (✻) VII (✻) VIII (✻) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 - 10 10 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 32 32 50 63 32 50 63 50 63 63 90 63 90 63 90 90 125 E290A390 E290B036 E290A391 E290B037 E290A392 E290B038 E290A039 E290A136 E290A040 E290A041 E290A042 E290A043 E290A623 E290A624 E290A797 E290A798 E290A399 E290B079 E290A799 E290A400 E290B080 E290A401 E290B081 E290A082 E290A137 E290A083 E290A084 E290A085 E290A086 E290A625 - (✻) Minimum pilot pressure varies with differential pressure, see page V402-7. (1) Calculation of the minimum pilot pressure at a ΔP of max. 10 bar with allowable backpressure (backpressure not recommended with liquids as waterhammer may occur). - 32 and 50 mm operators, 4 bar minimum pilot pressure version: add 2 bar to the minimum pilot pressure of chart V or X, page V402-7. - 63, 90 and 125 mm operators, 4 bar minimum pilot pressure version: add 1,5 bar to the minimum pilot pressure of chart VI, VII or VIII, page V402-7. All leaflets are available on: www.asconumatics.eu V410-2 00049GB-2010/R02 Availability, design and specifications are subject to change without notice. All rights reserved. NC - Normally closed, entry above the disc (version recommended for rapid-cycling steam applications) VALVES SERIES E290 OPTIONS AND ACCESSORIES (see page V435/V436) • • • • • • • • • • • Signaling box or compact signaling unit Stroke limiter for opening Manual safety device Optical position indicator on 32-50 mm operators, NC function Adapter plate for NAMUR pad mounting pilot (63-90-125 mm operators only) Oxygen service (except DN 65), pressure limited to 15 bar, temperature limited to + 60°C Vacuum applications up to 1,33 10-3 mbar NET-INOX passivation treatment on stainless steel body valve ATEX 94/9/EC versions for potentially explosive atmospheres Pilot operated drain valve assembly with electronic timer (see Solenoids, Coils & Accessories section) Other pipe connections are available on request INSTALLATION • • • • The valves can be mounted in any position without affecting operation Compatible with ASTM 1, 2 and 3 oils Pipe connections (G*) have standard combination thread according to ISO 228/1 and ISO 7/1 Installation/maintenance instructions are included with each valve SPARE PARTS KITS ORDERING EXAMPLES: spare parts kit no. DN 10 15 20 25 32 40 50 65 Ø 32 mm Ø 50-63-90-125 mm C140100 C140101 C140102 - C131204 (1) C131205 (1) C131206 (1) C131207 (1) C131208 (1) C131209 (1) C131622 (1) E E E E D 290 A 792 290 B 002 SM2 290 A 791 SU 290 A 082 pipe thread basic number suffix ORDERING EXAMPLES KITS: (1) Standard suffix VM also applies to kits (see V435). - Not available C140100 C140205 C140205 VM suffix basic number 32 mm operator 50 mm operator 63, 90 and 125 mm operators 00049GB-2011/R01 Availability, design and specifications are subject to change without notice. All rights reserved. 1 1 2 2 1 2 NO function 1 1 2 2 1 2 NC function, fluid entry above disc All leaflets are available on: www.asconumatics.eu V410-3 VALVES SERIES E290 DIMENSIONS (mm), WEIGHT (kg) TYPE 01-02 32 and 50 mm operators Fluid entry: under the disc at 2 above the disc at 1 ØF 1/8 0˚ D G 50 ˚ C 36 ØA type operator diameter 01 32 mm 02 50 mm (1) E H B ØA B C D E ØF G ØH weight (1) 3/8 1/2 3/4 1/2 3/4 1 92 99 107 142 150,5 155 93 97 104,5 154,5 159 165 81,5 83,5 88 141 143 145 55 65 75 65 75 90 43,5 43,5 43,5 69 69 69 27 27 27 43 43 43 23,5 28 30 27 32 41 0,35 0,4 0,45 0,9 1 1,4 Weight of valve without pilot. Solenoid pilot valves: see V440 (32 and 50 mm operators). TYPE 03-04-05 63, 90 and 125 mm operators Fluid entry: under the disc at 2 above the disc at 1 Ø 158 Ø 156 1 ØF 36 0° C D 1/8 (Ø63 mm) 1/4 (Ø90-125 mm) ØA H E B 1 Operator dia. 125 mm, NO function type (1) operator diameter 03 63 mm 04 90 mm 05 125 mm ØA 1/2 3/4 1 1 1/4 1 1/2 2 1 1 1/4 1 1/2 2 2 1/2 1 1/4 1 1/2 2 2 1/2 B C D 170 182 169 175 185 170 179 192 172 217 229 204 224 245 215 249 259 224 197 209 189 236 246 221 243 262 232 267 276 241 299 300 257 284 298 273 291 313,5 283,5 315 328 293 347 352 308 E ØF G ØH weight (1) 65 75 90 110 120 150 90 110 120 150 190 110 120 150 190 85 85 85 85 85 85 118 118 118 118 118 156 156 156 156 50,5 50,5 50,5 50,5 50,5 50,5 67 67 67 67 67 86 86 86 86 27 32 41 50 60 70 41 50 60 70 86 50 60 70 86 1,2 1,3 1,7 2,1 2,9 3,7 2,3 2,7 3,5 4,3 6,3 5,2 6 6,8 8,9 Weight of valve without pilot. Add 0,2 for dia. 125 mm operator NO. Solenoid pilot valves: see V439 (63 mm operator) / V444 (90 and 125 mm operators). All leaflets are available on: www.asconumatics.eu V410-4 00049GB-2009/R01 Availability, design and specifications are subject to change without notice. All rights reserved. 50 ° G VALVES 3/2 E390 2 NC pressure operated bronze body threaded ports, 1/2 to 2 Series 1 3 2 NO 1 3 FEATURES • • • • Remote-controlled valves with disc for industrial fluids Anti-waterhammer design (fluid entry under the disc) Vacuum operation up to 10-2 mbar Wide range of piston-type operators (63 - 90 -125 mm dia.) rotatable through 360°, for maximum performance at different minimum pilot pressures • High performance, maintenance-free stuffing box • The valves satisfy Pressure Equipment Directive 97/23/EC, category 1 (DN > 25) or article 3.3 (DN ≤ 25) GENERAL Differential pressure Maximum allowable pressure Ambient temperature range Maximum viscosity Pilot fluid Max. pilot pressure Min. pilot pressure Pilot fluid temperature Response time See «SPECIFICATIONS» [1 bar =100 kPa] 16 bar -10°C to +60°C 5000 cSt (mm2/s) Filtered air or water (1) 10 bar See below and following page -10°C to +60°C See page V402-7 fluids (✴) air and gas groups 1 & 2 water, oil, liquids groups 1 & 2 and steam temperature range disc seal (✴) - 10°C to + 184°C PTFE MATERIALS IN CONTACT WITH FLUID (✴) Ensure that the compatibility of the fluids in contact with the materials is verified Valve body Bronze Stuffing box housing Brass Stem Stainless steel Disc Stainless steel Stuffing box packing PTFE chevrons Wiper seal FPM Disc seal PTFE Valve body seal PTFE 3 NC function OTHER MATERIALS Operator Optical position indicator (1) 2 1 Glass fibre filled PA PA 12, supplied standard on valves with 63, 90 and 125 mm operators 2 1 3 NO function For dia. 63, 90 and 125 mm operators: At service fluid temperatures inside the valve body above 100°C, it is prohibited to pilot the valve with water. SPECIFICATIONS 00083GB-2011/R02 Availability, design and specifications are subject to change without notice. All rights reserved. piping (ISO 6708) pipe size DN (G*) flow coefficient Kv pilot pressure (bar) 3 2 2 1 min. (m3/h) (l/min) (m3/h) (l/min) min. max. operating pressure differential (bar) max. water, oil, air liquids gas operator diameter steam (✴) catalogue number (✴) (✴) (184°C) (mm) 16 4 16 10 16 5 11 6 12 4 8 16 6 10 4 10 10 10 5 10 6 10 4 8 10 6 63 63 63 63 90 63 90 63 90 63 90 125 90 E390B002 E390B001 E390B005 E390B010 E390B011 E390B008 E390B009 E390A016 E390A017 E390A020 E390A021 E390A482 E390A025 16 16 16 16 11 16 16 10 10 10 10 10 10 10 63 63 63 90 63 125 125 E390B026 E390B027 E390B028 E390A031 E390A032 E390A489 E390A490 NC - Normally closed, entry under the disc 1 1/4 32 24 400 18 300 5 10 0 1 1/2 40 42,9 715 31,8 530 5 10 0 2 50 52,8 880 39 650 5 10 0 16 4 16 10 16 5 11 6 12 4 8 16 6 II (✻) II (✻) II (✻) III (✻) II (✻) IV (✻) IV (✻) 10 10 10 10 10 10 10 0 0 0 0 0 0 0 16 16 16 16 11 16 16 1/2 15 6 100 4,5 75 3/4 20 9,6 160 7,2 120 1 25 16,2 270 12 200 3 2 5 10 10 10 0 0 0 5 10 0 3 10 0 NO - Normally open, entry under the disc 1/2 3/4 1 1 1/4 15 20 25 32 6 9,6 16,2 24 100 160 270 400 4,5 7,2 12 18 75 120 200 300 1 1/2 40 42,9 715 31,8 530 2 50 52,8 880 39 650 (✻) Minimum pilot pressure varies with differential pressure, see page V402-7. All leaflets are available on: www.asconumatics.eu V703-1 F VALVES SERIES E390 OPTIONS AND ACCESSORIES (see page V435/V436) • • • • • • • • Signaling box or compact signaling unit Stroke limiter for opening Adapter plate for NAMUR pad mounting pilot Oxygen service, pressure limited to 15 bar, temperature limited to + 60°C Vacuum applications up to 1,33 10-3 mbar 3/2 version for mixing or distributing operations ATEX 94/9/EC versions for potentially explosive atmospheres Other pipe connections are available on request INSTALLATION • • • • The valves can be mounted in any position without affecting operation Compatible with ASTM 1, 2 and 3 oils Pipe connections (G*) have standard combination thread according to ISO 228/1 and ISO 7/1 Installation/maintenance instructions are included with each valve ORDERING EXAMPLES SPARE PARTS KITS DN 15 20 25 32 40 50 (2) E E E spare parts kit no. Ø 63-90-125 mm C140021 (2) C140022 (2) C140023 (2) C140024 (2) C140025 (2) C140026 (2) 390 B 002 390 B 011 SM2 390 A 030 pipe thread basic number suffix Standard suffix VM also applies to kits (see V435).. ORDERING EXAMPLES KITS: C140021 C140022 C140024 VM suffix basic number DIMENSIONS (mm), WEIGHT (kg) TYPE 01-02-03 63, 90 and 125 mm operators Fluid entry: under the disc at 3 ØF 1/8 (Ø63 mm) 1/4 (Ø90-125 mm) 1 C 360° G ØA 1 type B 2 D 1 operator diameter 3 01 63 mm 02 90 mm 03 125 mm Operator dia. 125 mm, NO function (3) All leaflets are available on: www.asconumatics.eu V703-2 ØA B C D ØF G weight (3) 1/2 3/4 1 1 1/4 1 1/2 1 1 1/4 1 1/2 2 1 1/2 2 39 44 52 57 61 52 57 61 69 61 69 198 203 212 237 244 223,5 248 255 264 309 318 68 84 92 110 125 92 110 125 145 125 145 85 85 85 85 85 118 118 118 118 156 156 50,5 50,5 50,5 50,5 50,5 67 67 67 67 86 86 1,6 1,9 2,6 3,2 4,5 3,2 3,7 5,2 6,2 7,7 8,7 Weight of valve without pilot. Add 0,2 for dia. 125 mm operator NO. Solenoid pilot valves: see V439 (63 mm operator) / V443 (90 and 125 mm operators). 00083GB-2010/R02 Availability, design and specifications are subject to change without notice. All rights reserved. Ø 158 Ø 156 VALVES 2/2 S290 NC pressure operated stainless steel body CLAMP or butt welding connection DN 10 to 65 Series 1 NO 2 FEATURES • Valve with clamp type connection to ISO 2852 for quick disconnection, a system commonly used in the food processing industry or with butt welding connection to ISO 6761 for stainless steel pipe to ISO 1127 • CLAMP valve body pickled in nitric/fluoric acid bath (NET-INOX passivation treatment) • High flow due to angled seat design • Anti-waterhammer design (fluid entry under the disc) • Vacuum operation up to 10-2 mbar • Wide range of piston-type operators (32 - 50- 63 - 90 -125 mm dia.) rotatable through 360°, for maximum performance at different minimum pilot pressures • High performance, maintenance-free stuffing box • The valves satisfy Pressure Equipment Directive 97/23/EC, category 1 (DN > 25) or article 3.3 (DN ≤ 25) GENERAL Differential pressure Maximum allowable pressure Ambient temperature range Maximum viscosity Pilot fluid Max. pilot pressure Min. pilot pressure Pilot fluid temperature Response time See «SPECIFICATIONS» [1 bar =100 kPa] 16 bar -10°C to +60°C 5000 cSt (mm2/s) Filtered air or water (1) 10 bar See below and following page -10°C to +60°C See page V402-7 fluids (✴) temperature range disc seal (✴) DN 50 : air et gaz groupes 1 & 2 DN 65: air and gas group 2 all DN: water, oil, liquids groups 1 & 2 and steam - 10°C to + 184°C PTFE D 1 2 NC function, entry under the disc, 32 and 50 mm operators MATERIALS IN CONTACT WITH FLUID (✴) Ensure that the compatibility of the fluids in contact with the materials is verified Valve body CLAMP connection AISI 316L (NET-INOX treatment) Butt welding connection AISI 316L Stuffing box housing AISI 316L Stem Stainless steel Disc Stainless steel Stuffing box packing PTFE chevrons Wiper seal FPM Disc seal PTFE Valve body seal PTFE 1 2 NC function, entry under the disc, 63, 90 and 125 mm operators CLAMP connection (not supplied) CLAMP connection Operator Optical position indicator (1) Butt welding connection Glass fibre filled PA PA 12, supplied standard on valves with 63, 90 and 125 mm operators For dia. 32, 50, 63, 90 and 125 mm operators: At service fluid temperatures inside the valve body above 100°C, it is prohibited to pilot the valve with water. SPECIFICATIONS DN O.D. of stub (clamp) O.D. of stub (butt) 00052GB-2011/R02 Availability, design and specifications are subject to change without notice. All rights reserved. OTHER MATERIALS flow coefficient Kv pilot pressure (bar) operating pressure differential (bar) max. min. (mm) (mm) (m3/h) (l/min) min. max. air, inert gas, aggressive fluids(✴) catalogue number operator diameter water, oil, liquids, aggressive liquids(✴) steam (✴) (184°C) (mm) 16 12 16 16 6 10 16 12 6 10 16 6 12 10 10 10 10 6 10 10 10 6 10 10 6 10 32 32 50 63 32 50 63 63 50 63 90 63 90 clamp connection butt welding connection S290A800 S290A804 S290A408 S290B137 S290A808 S290A409 S290B140 S290B139 S290A410 S290B145 S290B146 S290B143 S290B144 S290A802 S290A806 S290A417 S290B205 S290A810 S290A418 S290B208 S290B207 S290A419 S290B211 S290B212 S290B210 - NC - Normally closed, entry under the disc (1) 10 34 17,2 15 34 21,3 20 50,5 26,9 25 50,5 33,7 2,8 4,1 47 68 4,9 82 6,5 108 9,4 157 12,8 213 16,5 275 4 4 4 2,5 4 10 10 10 10 10 0 0 0 0 0 4 10 0 2,5 4 10 10 0 0 4 10 0 2,5 10 0 16 12 16 16 6 10 16 12 6 10 16 6 12 All leaflets are available on: www.asconumatics.eu V420-1 VALVES SERIES S290 DN O.D. of stub (clamp) O.D. of stub (butt) SPECIFICATIONS flow coefficient Kv pilot pressure (bar) operating pressure differential (bar) max. min. (mm) (mm) (m3/h) (l/min) min. max. water, oil, liquids, aggressive liquids(✴) steam (✴) (184°C) (mm) 6 12 3 16 4 8 4 16 2,5 6 2,5 10 5 2 6 1 6 12 3 16 4 8 4 16 2,5 6 2,5 10 5 2 6 1 6 10 3 10 4 8 4 10 2,5 6 2,5 10 5 2 6 1 16 16 16 16 16 16 16 16 16 16 11 13 16 7 16 16 16 16 16 16 16 16 16 16 16 11 13 16 7 16 10 10 10 10 10 10 10 10 10 10 10 10 10 7 10 air, inert gas, aggressive fluids(✴) catalogue number operator diameter clamp connection butt welding connection 63 90 63 125 63 90 90 125 63 90 90 125 125 90 125 125 S290A151 S290A155 S290A156 S290A154 S290A521 S290A687 S290A688 S290A685 S290A689 S290A686 S290A691 S290A690 S290A692 S290A215 S290A216 S290A214 S290A670 S290A217 S290A218 S290A573 S290A719 S290A720 S290A721 S290A722 S290A723 32 32 50 63 32 50 63 50 63 63 63 63 90 90 125 S290A812 S290A816 S290A411 S290B161 S290A820 S290A412 S290B162 S290A413 S290B163 S290A164 S290A165 S290A693 S290A694 S290A695 S290A696 S290A814 S290A818 S290A420 S290B221 S290A822 S290A421 S290B222 S290A422 S290B223 S290A224 S290A225 S290A724 S290A725 S290A726 S290A727 NC - Normally closed, entry under the disc (1) 32 40 50 65 64 64 77,5 91 42,4 48,3 27 450 29 483 45 750 48 800 59 983 60,3 76,1 66 1100 94 1567 111 1850 4 10 0 2,5 4 10 10 0 0 4 10 0 2,5 4 10 10 0 0 4 10 0 2,5 4 2,5 4 4 2,5 10 10 10 10 10 10 0 0 0 0 0 0 NO - Normally open, entry under the disc 10 34 17,2 2,8 4,1 15 34 21,3 20 50,5 26,9 25 50,5 33,7 32 40 64 64 42,4 48,3 12,8 16,5 27 45 50 77,5 60,3 59 65 91 76,1 94 111 4,9 6,5 9,4 IX (✻) IX (✻) I (✻) 82 II (✻) 108 IX (✻) I (✻) 157 II (✻) I (✻) 213 275 II (✻) 450 II (✻) 750 II (✻) II (✻) 983 III (✻) 1567 III (✻) 1850 IV (✻) 47 68 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 34 17,2 15 34 21,3 20 50,5 26,9 25 50,5 33,7 32 64 40 50 65 2,8 4,1 47 68 4,9 82 6,5 108 9,4 157 42,4 12,8 16,5 27 213 275 450 64 48,3 45 750 77,5 60,3 59 983 76,1 94 111 1567 1850 91 X (✻) X (✻) V (✻) VI (✻) X (✻) V (✻) VI (✻) V (✻) VI (✻) VI (✻) VI (✻) VII (✻) VI (✻) VII (✻) VII (✻) VIII (✻) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 - 10 10 10 10 10 10 10 10 10 10 10 10 9 10 10 10 32 32 50 63 32 50 63 50 63 63 63 90 63 90 90 125 S290A824 S290A828 S290A414 S290B167 S290A832 S290A415 S290B168 S290A416 S290B169 S290A170 S290A171 S290A697 S290A698 S290A699 S290A700 S290A826 S290A830 S290A423 S290B227 S290A834 S290A424 S290B228 S290A425 S290B229 S290A230 S290A231 S290A259 S290A728 S290A729 S290A730 S290A731 (✻) Minimum pilot pressure varies with differential pressure, see page V402-7. (1) Calculation of the minimum pilot pressure at a ΔP of max. 10 bar with allowable backpressure (backpressure not recommended with liquids as waterhammer may occur). - 32 and 50 mm operators, 4 bar minimum pilot pressure version: add 2 bar to the minimum pilot pressure of chart V or X, page V402-7.. - 63, 90 and 125 mm operators, 4 bar minimum pilot pressure version: add 1,5 bar to the minimum pilot pressure of chart VI, VII or VIII, page V402-7. All leaflets are available on: www.asconumatics.eu V420-2 00052GB-2010/R03 Availability, design and specifications are subject to change without notice. All rights reserved. NC - Normally closed, entry above the disc (version recommended for rapid-cycling steam applications) 10 VALVES SERIES S290 OPTIONS AND ACCESSORIES (see page V435/V436) • • • • • • • • • Signaling box or compact signaling unit Stroke limiter for opening Manual safety device Optical position indicator on 32-50 mm operators, NC function Adapter plate for NAMUR pad mounting pilot (63-90-125 mm operators only) Oxygen service (except DN 65), pressure limited to 15 bar, temperature limited to + 60°C Vacuum applications up to 1,33 10-3 mbar NET-INOX passivation treatment on valve body with butt welding connection ATEX 94/9/EC versions for potentially explosive atmospheres INSTALLATION • The valves can be mounted in any position without affecting operation • On clamp connection version: The connection stubs comply with ISO 2852. The strength of the quick-disconnect connection clamp must be compatible with the maximum pressure applied to the valve • On butt welding version: Compatible with ASTM 1, 2 and 3 oils Butt welding connections comply with ISO 6761 and are compatible with pipe to ISO 1127 • Installation/maintenance instructions are included with each valve SPARE PARTS KITS ORDERING EXAMPLES: spare parts kit no. DN 10 15 20 25 32 40 50 65 Ø 32 mm Ø 50-63-90-125 mm C140100 C140101 C140102 - C131204 (1) C131205 (1) C131206 (1) C131207 (1) C131208 (1) C131209 (1) C131622 (1) S S S S D 290 A 804 290 B 137 SM2 290 A 155 SU 290 A 170 pipe thread basic number suffix ORDERING EXAMPLES KITS: (1) Standard suffix VM also applies to kits (see V435). - Not available C140100 C140205 C140205 VM suffix basic number DIMENSIONS (mm), WEIGHT TYPE 01-02-03-04-05 Ø 158 Ø 156 1 ØF type 1/8 (Ø32-50-63 mm) 1/4 (Ø90-125 mm) 01 0° 36 C D 02 50 ° G ØH 2 ØJ 03 1 E ØA B ØJ ØH 04 ØA 00052GB-2011/R01 Availability, design and specifications are subject to change without notice. All rights reserved. 32, 50, 63, 90 and 125 mm operators Fluid entry: under the disc at 2 above the disc at 1 05 (1) 1 Operator dia. 125 mm, NO function operator DN diameter 10 32 15 20 15 50 20 25 15 20 25 63 32 40 50 25 32 40 90 50 65 32 40 125 50 65 ØA B C D 10 16 20 15,5 21,5 26 15,5 21,5 26 35 41 50 26 35 41 50 65 35 41 50 65 102,5 110,7 111,6 153 158 167 182 184 191 226 235 257 209 245 254 275 302 291 301 322,5 349,5 104,7 105,8 113,6 158,5 168 170,5 186 195 197 236 247 263 214 253 264 280 302,5 307 316 332 353,5 87,7 88,8 88,4 141 143 145 169 170 172 204 215 224 189 221 232 241 257 273 284 293 308 E ØF 80 43,5 101,6 43,5 114 43,5 102 69 114 69 129 69 102 85 114 85 129 85 140 85 159 85 180 85 129 118 140 118 159 118 180 118 205 118 140 156 159 156 180 156 205 156 G ØH ØJ 27 27 27 43 43 43 50,5 50,5 50,5 50,5 50,5 50,5 67 67 67 67 67 86 86 86 86 34 34 50,5 34 50,5 50,5 34 50,5 50,5 64 64 77,5 50,5 64 64 77,5 91 64 64 77,5 91 27,5 27,5 43,5 27,5 43,5 43,5 27,5 43,5 43,5 56,5 56,5 70,5 43,5 56,5 56,5 70,5 83,5 56,5 56,5 70,5 83,5 weight (1) 0,4 0,43 0,59 0,9 1 1,4 1,2 1,3 1,7 2,1 2,8 3,7 2,2 2,7 3,4 4,2 6,2 5,2 5,9 6,7 8,8 Weight of valve without pilot. Add 0,2 for dia. 125 mm operator NO. Solenoid pilot valves: see V439 (63 mm operator) / V444 (90 and 125 mm operators). All leaflets are available on: www.asconumatics.eu V420-3 VALVES SERIES S290 DIMENSIONS (mm), WEIGHT TYPE 01-02-03-04-05 32, 50, 63, 90 and 125 mm operators Fluid entry: under the disc at 2 above the disc at 1 Ø 158 Ø 156 1/8 (Ø32-50-63 mm) 1/4 (Ø90-125 mm) ØF type 1 01 0° D 02 G 50 ° C1 36 ØA 03 2 1 E1 H1 B1 ØH1 ØA 04 05 1 (1) Operator dia. 125 mm, NO function 32 mm operator operator DN diameter 10 32 15 20 15 50 20 25 15 20 25 63 32 40 50 25 32 40 90 50 65 32 40 125 50 65 ØA B1 C1 D 10 16 20 15,5 21,5 26 15,5 21,5 26 35 41 50 26 35 41 50 65 35 41 50 65 102,5 101,9 103,6 144 150 159 172 175 183 218 227 249 201 237 246 267 294 283 294 314,5 341,5 96,9 100,5 102,4 152 157 162 181 184 190 226 240 254 207 243 257 271 295 295 308 323 346 87,7 88,8 88,4 141 143 145 169 170 172 204 215 224 189 221 232 241 257 273 284 293 308 E1 ØF 80 84 98 84 98 113 84 98 113 124 143 164 113 124 143 164 189 124 143 164 189 43,5 43,5 43,5 69 69 69 85 85 85 85 85 85 118 118 118 118 118 156 156 156 156 G ØH1 27 27 27 43 43 43 50,5 50,5 50,5 50,5 50,5 50,5 67 67 67 67 67 86 86 86 86 17,2 21,3 26,9 21,3 26,9 33,7 21,3 26,9 33,7 42,4 48,3 60,3 33,7 42,4 48,3 60,3 76,1 42,4 48,3 60,3 76,1 weight (1) 0,37 0,4 0,45 0,9 1 1,3 1,2 1,3 1,6 2 2,7 3,6 2,1 2,6 3,3 4,1 6,1 5,1 5,8 6,7 8,7 Weight of valve without pilot. Add 0,2 for dia. 125 mm operator NO. Solenoid pilot valves: see V439 (63 mm operator) / V444 (90 and 125 mm operators). 50 mm operator 63, 90 and 125 mm operators 1 2 1 2 2 NO function 1 1 2 1 2 2 NC function, entry above the disc All leaflets are available on: www.asconumatics.eu V420-4 00052GB-2009/R01 Availability, design and specifications are subject to change without notice. All rights reserved. 1 PROPORTIONAL VALVES WITH POSITIONERD 2 way 3 way 1• • • P • NC pressure operated all standard connection types 2 Series • (2) (1) 290/390 2• 3 1 • •• P • • (2) (1) FEATURES Kv • Precise, quick-acting and robust valve suitable for use in outside industrial environments • Exceptional long service life • Variable flow proportional to the control signal • Real-time control • Ready-to-use valve • The positioner can be directly connected to an external sensor (double loop control) • Power saving function and no air consumption when position is reached • Manual valve operator • LED indicators for valve status display B input control signal GENERAL Differential pressure 0 to 16 bar [1 bar =100 kPa] Maximum allowable pressure 16 bar Ambient temperature range 0°C to +50°C Maximum viscosity 5000 cSt (mm2/s) Pilot fluid Air or inert gas, filtered 25 µm, unlubricated, condensate-free and water-free (observe the pressure dew point) (6) Pilot pressure 4 to 8 bar Pilot fluid temperature 0°C to +50°C Response time See page V402-7 Fluids For type, temperature and materials compatibility, see the catalogue pages for the standard valves V410, V420, V431 and V703 ELECTRICAL CHARACTERISTICS Setpoint reached output ON/OFF, 24 V PNP / max. 500 mA Analog position feedback signal 0-10 V / 4-20 mA Analog setpoint 0-10V (Rin = 200 kΩ); 4-20 mA (Rin = 250 Ω) Nominal supply voltage 24 V DC ± 10%, max. ripple 10% Power 7,6 W (3,6 W, setpoint reached) Connection Screw terminals, cable gland (cable Ø 5-10 mm) or connection M12 (CNOMO E03.62.520.N) Degree of protection IP66 (EN 60529) Electromagnetic compatibility EMC 2004/108/EC Regulation characteristics Hysteresis < 2% ; Accuracy < 2 % ; Repeatability < 1 % CONSTRUCTION Valve construction Valve disc (2/2) Valve disc (3/2) Positioner body Cable gland Cover 2 See sections D and F Profiled disc, stainless steel and PTFE Standard disc PA (polyamide), 6/6 GF 30% (glass fibre reinforced) Steel (cable Ø 4,5-9 mm) PA 12, transparent double loop for positioner with directly connected external sensor single loop 00196GB-2012/R03 Availability, design and specifications are subject to change without notice. All rights reserved. 1 Pp Pp (1) (1) (2) (2) open or closed loop control Setpoint Value measured by the process sensor (1) closed loop control (2) SPECIFICATIONS (NC valves, fluid entry under the disc) suffix for proportional valve and positioner (3) delivered assembled analog setpoint 2 way fail in last position (4) fail close (5) 2 way 3 way (7) 3 way (7) cable gland M12 cable gland M12 cable gland M12 cable gland M12 0 - 10 V DC 4 - 20 mA PDB64 PDB65 PDB68 PDB69 B64 B65 B68 B69 PDB66 PDB67 PDB70 PDB71 B66 B67 B70 B71 0 - 10 V DC 4 - 20 mA - - - - PDB72 PDB73 PDB74 PDB75 B72 B73 B74 B75 Positioner , single loop D PositionerD, double loop Place the indicated suffix after the catalogue number of the valve selected. Valve disc remains in its last position on loss of power. Valve returns to closed position on loss of power. The actuator exhaust air is used to ventilate the electronics housing. Top orifice of this version is not tight, for the tight version contact us. (3) (6) (4) (7) (5) All leaflets are available on: www.asconumatics.eu V162-1 PROPORTIONAL VALVE + PositionerD SERIES 290/390 VALVE SPECIFICATIONS orifice size pipe size (DN) 2 way (2) operator diameter max. min. (mm) flow coefficient (Kv), programmable opening of proportional valve 2 way, threaded 2 way, flanges 3 way, threaded pilot pressure (bar) (1) 3 way bronze, stainless steel (E290) (V410) clamp / butt welding (S290) (V420) bronze (E390) (V703) bronze (T290) (V431) (mm) (m3/h) (l/min) (m3/h) (l/min) (m3/h) (l/min) 63 63 90 63 63/90 63/90 125 63/90 125 63/90 125 90 125 7,1 15 21 22 29 44 40 66 68 74 118 250 350 367 483 733 667 1100 1133 1233 11 14 15 21 32 26,5 44 - 183 233 250 350 533 442 733 - 6 9,6 16,2 24 42,9 42,9 52,8 52,8 - 100 160 270 400 715 715 880 880 - NC - Normally closed, entry under the disc 1/2 (15) 15 3/4 (20) 20 1 (25) 25 1 1/4 (32) 32 1 1/2 (40) 40 2 (50) 50 2 1/2 (65) 65 3/5 3/5 3/5 3/5 4 4 4 4 4 4 2/3 3/5 3/5 5 3/5 3/5 5 5 5 - 8 8 8 8 8 8 8 8 8 8 8 8 For best control loop operation, we recommend the following pilot pressures: max. 3 bar (valve with 1,5 bar operator) ; max. 5 bar (valve with 2,5 bar operator) ; max. 7 bar (valve with 4 bar operator) (2) 3 bar (valve with 2,5 bar operator) ; 5 bar or 4 bar (valve with 4 bar operator) (1) OPTIONS AND ACCESSORIES • Standard 2/2 NC valve, fluid entry under the disc, with profiled disc only, use suffix PD, example: E290A016PD • Female M12 connector: straight - 5 pins, with screw terminals, catalogue number: 88100256 - Supply cable 5 m, 5 x 0,25 mm2, catalogue number: 88130212 - Supply cable 5 m, 6 x 0,5 mm2, catalogue number: 88100728 - Supply cable 10 m, 6 x 0,5 mm2, catalogue number: 88100730 • APC software for modification of control parameters (software required for double loop control) available for download at: www.asconumatics.eu • RS-232 converter, 2 m cable with 9 pin Sub-D connector for PC link, catalogue number 88100732 • Oxygen service (except DN 65), pressure limited to 15 bar, temperature limited to + 60°C, suffix N • Vacuum applications up to 1,33 10-3 mbar, suffix VM • Other pipe connections are available on request INSTALLATION diagnostics hold position valve OPEN valve CLOSED valve moves to open valve moves to close positioner in initialisation mode positioner in manual mode setpoint > 20,5 mA / 10,25 V setpoint < 3,5 mA positioner not initialised component error Electrical connection: PositionerD, single loop PositionerD, double loop screw terminals M12 1 screw terminals 4 M12 1 5 2 1 2 3 4 6 7 + 24 V DC, supply GND supply + setpoint (0-10 V or 4-20 mA) GND setpoint disc position feedback + 24V ON/OFF output 3 1 3 2 3 4 5 2 1 2 3 4 5 7 All leaflets are available on: www.asconumatics.eu V162-2 4 5 + 24 V DC, supply GND supply + setpoint (0-10 V or 4-20 mA) GND setpoint external sensor input + 24V ON/OFF output 3 1 3 2 3 4 5 00196GB-2012/R02 Availability, design and specifications are subject to change without notice. All rights reserved. Pilot port G 1/8 according to ISO 228/1 Compatible with ASTM 1, 2 and 3 oils Installation/maintenance instructions are included with each valve LED indicators for operating status display and diagnostic functions (Unit can be rotated through 360° around the centreline of the valve operator) status • • • • PROPORTIONAL VALVE + PositionerD SERIES 290/390 SPARE PARTS KITS ORDERING EXAMPLES: spare parts kit no. PositionerD only cable gland (cable Ø 5-10 mm) E E E E connection M12 Fail position maintained, single loop 0-10 V 4-20 mA 60568108 60568308 60569108 60569308 0-10 V 4-20 mA 60568118 60568318 60569118 60569318 Fail close, single loop Fail close, double loop 0-10 V 4-20 mA 60568418 60568518 60569418 60569518 all C140423 C140423 Mounting kit bronze, stainless steel (E290) clamp / butt welding (S290) PDB64 B64 PDB68 PDB71 pipe thread basic number suffix ORDERING EXAMPLES KITS: C131204 C140206 C140205 VM suffix basic number spare parts kit no. pipe size (DN) 290 A 016 390 A 016 290 A 059 290 A 102 bronze (T290) bronze (E390) C140017 (1) C140018 (1) C140019 (1) C140020 (1) - C140021 (1) C140022 (1) C140023 (1) C140024 (1) C140025 (1) C140026 (1) - Valve disc seals C131204 (1) C131205 (1) C131206 (1) C131207 (1) C131208 (1) C131209 (1) C131622 (1) 1/2 (15) 3/4 (20) 1 (25) 1 1/4 (32) 1 1/2 (40) 2 (50) 2 1/2 (65) (1) Standard suffix VM is also applicable to kits (see V435). - Not available. DIMENSIONS (mm), WEIGHT (kg) TYPE 01 TYPE 02 Enclosure with cable gland 63 to 125 mm operator Fluid entry: under the disc at 2 Enclosure with M12 connection 63 to 125 mm operator Fluid entry: under the disc at 2 85 84 112 57 00196GB-2012/R01 Availability, design and specifications are subject to change without notice. All rights reserved. 112 60 2 1 2 1/8 1 1/8 2 1 3 3 1 1 2 2 1 2 3 M16 x 1,5 mm cable gland (cable Ø 4,5-9 mm) M12 connection G 1/8 pilot connection Weight of positioner without valve: 0,3 kg All leaflets are available on: www.asconumatics.eu V162-3 B 00196GB-2008/R01 Availability, design and specifications are subject to change without notice. All rights reserved. PROPORTIONAL VALVE + PositionerD SERIES 290/390 All leaflets are available on: www.asconumatics.eu V162-4 VALVES 2/2 T290 NC pressure operated bronze body with flanges PN16, DN 25 to 50 Series 1 NO 2 FEATURES • • • • Remote-controlled valves with disc for industrial fluids Anti-waterhammer design (fluid entry under the disc) Vacuum operation up to 10-2 mbar Wide range of piston-type operators (63 - 90 -125 mm dia.) rotatable through 360°, for maximum performance at different minimum pilot pressures • High performance, maintenance-free stuffing box • The valves satisfy Pressure Equipment Directive 97/23/EC, category 1 (DN > 25) or article 3.3 (DN 25) GENERAL Differential pressure Maximum allowable pressure Ambient temperature range Maximum viscosity Pilot fluid Max. pilot pressure Min. pilot pressure Pilot fluid temperature Response time See «SPECIFICATIONS» [1 bar =100 kPa] 16 bar -10°C to +60°C 5000 cSt (mm2/s) Filtered air or water (1) 10 bar See below and following page -10°C to +60°C See page V402-7 fluids (✴) temperature range disc seal (✴) air and gas groups 1 & 2 water, oil, liquids groups 1 & 2 and steam - 10°C to + 184°C PTFE D CONSTRUCTION 2 Connection Facing MATERIALS IN CONTACT WITH FLUID NC function, entry under the disc (✴) Ensure that the compatibility of the fluids in contact with the materials is verified Valve body Bronze Stuffing box housing Brass Stem Stainless steel Disc Brass Stuffing box packing PTFE chevrons Wiper seal FPM Disc seal PTFE Valve body seal PTFE 2 1 OTHER MATERIALS Operator Optical position indicator (1) 1 Flange type 21 (ISO 7005) - PN 16 Type A Glass fibre filled PA PA 12, supplied standard on valves with 63, 90 and 125 mm operators NO function 2 1 NC function, entry above the disc For dia. 63, 90 and 125 mm operators: At service fluid temperatures inside the valve body above 100°C, it is prohibited to pilot the valve with water. 00053GB-2011/R02 Availability, design and specifications are subject to change without notice. All rights reserved. SPECIFICATIONS DN orifice size (mm) flow coefficient Kv pilot pressure (bar) operating pressure differential (bar) max. min. (m3/h) (l/min) min. max. operator diameter catalogue number air inert gas (✴) water, oil, liquids (✴) steam (✴) (184°C) (mm) 10 16 6 12 6 12 7 4 8 16 10 2,5 6 10 5 10 10 6 10 6 10 7 4 8 10 10 2,5 6 10 5 63 90 63 90 63 90 90 63 90 125 125 63 90 125 125 T290A010 T290A011 T290A008 T290A009 T290A016 T290A017 T290A015 T290A020 T290A021 T290A482 T290A481 T290A024 T290A025 T290A485 T290A484 16 16 16 16 10 10 10 10 63 90 63 125 T290A028 T290A029 T290A030 T290A643 NC - Normally closed, entry under the disc (1) 25 32 40 50 25 32 18 300 2,5 10 32 530 4 10 0 35 583 4 2,5 10 10 0 0 39 650 4 10 0 733 4 2,5 10 10 0 0 10 16 6 12 6 12 7 4 8 16 10 2,5 6 10 5 0 0 0 0 16 16 16 16 12 10 0 2,5 10 0 4 10 0 0 200 40 50 44 4 NO - Normally open, entry under the disc 25 25 12 200 32 32 18 19 300 317 II (✻) III (✻) II (✻) IV (✻) 10 10 10 10 All leaflets are available on: www.asconumatics.eu V431-1 VALVES SERIES T290 SPECIFICATIONS DN flow coefficient Kv orifice size pilot pressure (bar) operating pressure differential (bar) max. min. (m3/h) (l/min) min. max. (mm) operator diameter air inert gas (✴) water, oil, liquids (✴) steam (✴) (184°C) (mm) 11 16 16 13 16 11 16 16 13 16 10 10 10 10 10 63 90 125 90 125 catalogue number NO - Normally open, entry under the disc 40 40 50 50 32 530 35 39 44 583 650 733 II (✻) III (✻) IV (✻) III (✻) IV (✻) 10 10 10 10 10 0 0 0 0 0 T290A032 T290A033 T290A489 T290A035 T290A490 NC - Normally closed, entry above the disc (version recommended for rapid-cycling steam applications) 25 25 12 200 32 32 18 300 40 40 32 530 50 50 39 650 VI (✻) VI (✻) VII (✻) VI (✻) VII (✻) VI (✻) VII (✻) 10 10 10 10 10 10 10 0 0 0 0 0 0 0 10 10 10 10 10 9 10 - 10 10 10 10 10 9 10 63 63 90 63 90 63 90 T290A038 T290A039 T290A136 T290A040 T290A041 T290A042 T290A043 (✻) Minimum pilot pressure varies with differential pressure, see page V402-7. (1) Calculation of the minimum pilot pressure at a ΔP of max. 10 bar with allowable backpressure (backpressure not recommended with liquids as waterhammer may occur) 63, 90 and 125 mm operators, 4 bar minimum pilot pressure version: add 1,5 bar to the minimum pilot pressure of chart VI, VII or VIII, page V402-7. OPTIONS AND ACCESSORIES (see page V435/V436) • • • • • • • Signaling box or compact signaling unit Stroke limiter for opening Manual safety device Adapter plate for NAMUR pad mounting pilot Oxygen service, pressure limited to 15 bar, temperature limited to + 60°C Vacuum applications up to 1,33 10-3 mbar ATEX 94/9/EC versions for potentially explosive atmospheres INSTALLATION • The valves can be mounted in any position without affecting operation • Compatible with ASTM 1, 2 and 3 oils • Installation/maintenance instructions are included with each valve SPARE PARTS KITS ORDERING EXAMPLES: spare parts kit no. Ø 63-90-125 mm C140017 (2) C140018 (2) C140019 (2) C140020 (2) 25 32 40 50 (2) T T T Standard suffix VM also applies to kits (see V435). pipe thread basic number C140017 C140018 C140019 63, 90 and 125 mm operators Fluid entry: under the disc at 2 above the disc at 1 2 type C 01 B 1 G 2 1 ØJ ØA 02 ØL 4 x ØK E D E Flange type 21 with flat faces, type A (ISO 7005) Operator dia. 125 mm, NO function All leaflets are available on: www.asconumatics.eu V431-2 suffix ØF 1/8 (Ø63 mm) 1/4 (Ø90-125 mm) 2 VM basic number 360° 1 suffix ORDERING EXAMPLES KITS: DIMENSIONS (mm), WEIGHT TYPE 01-02-03 Ø 158 Ø 156 290 A 010 290 A 011 SM2 290 A 030 03 (3) operator ØA diameter 25 32 63 40 50 25 32 90 40 50 32 125 40 50 B C D 288 313 329 354 303 325 341 365 378 394 418 230 243 254 271 246 255 266 283 308 319 336 110 130 140 160 110 130 140 160 130 140 160 E ØF 12 14 14 16 12 14 14 16 14 14 16 85 85 85 85 118 118 118 118 156 156 156 G 50,5 50,5 50,5 50,5 67 67 67 67 86 86 86 ØJ ØK ØL 115 140 150 165 115 140 150 165 140 150 165 14 18 18 18 14 18 18 18 18 18 18 85 100 110 125 85 100 110 125 100 110 125 Weight of valve without pilot. Add 0,2 for dia. 125 mm operator NO. Solenoid pilot valves: see V439 (63 mm operator) / V444 (90 and 125 mm operators). weight (3) 3,9 5,9 7,1 10,5 4,5 6,5 7,7 11,1 9 10,2 13,6 00053GB-2010/R02 Availability, design and specifications are subject to change without notice. All rights reserved. DN www.eci.co Sede Bogotá D.C, Colombia Transversal 18Bis No 38-41 Calle 23 No 116-31 Bod. 32 Tel: +57(1) 3275151 Fax: +57(1) 2884838 / 2885589 [email protected] [email protected] Sede Quito, Ecuador Suiza 361 y República de El Salvador Ed. Euro, Oficina 7B Tel: +593(2) 600 6882 Fax: +593(2) 333 2567
Similar documents
8290 SERIES| Angle Body Piston Valves
• Visual Position Indicator for normally closed valve with 32mm or 50mm operator, add suffix “VI” (note: position indicator standard on 63mm through 125mm operators). • NET-INOX treatment (stainles...
More informationPopular Parts List - oe
LOWER LINK END ASSY OEM 464-2 OUTER TRACK ROD END ASSY OEM 478-2 ROD END TFR ROD END RH OEM 953-1 ROD END LH OEM 954-2 UPPER LINK END ASSY OEM 453-3 CYLINDER ASSY, CLUTCH MASTER CYLINDER KIT, CLUTC...
More information