1435 ePos - Williams
Transcription
1435 ePos - Williams
Intelligent Positioner Construction The digital electro-pneumatic positioner detects the valve position with an external LongLife travel sensor. It has a solid housing with protected operating keys and an easy to read LCD display. The operating times can be set by integrated throttles. Connection and mounting to NAMUR is also possible. Features • • • • • • • Simple and self-explanatory menu Automatic initialisation function Safety function during power or compressed air supply failure Protection class IP 65 3/4-wire type Can be used with linear and quarter turn actuators Operation with single and double acting actuators Advantages • • • • • Separate mounting of positioner and travel sensor Simple handling and commissioning Simple electrical connection by detachable terminals Automatic optimization of valve control during initialisation No air consumption when idle Front view GEMÜ 1435 ePos ePos 1435 1435 ePos Technical data General specifications Operating conditions Protection class acc. to EN 60529 IP 65 Dimensions L x W x H 160 x 90 x 84 mm Weight 1.6 kg Mounting position optional EC EMC directive 89/336/EEC EC low voltage directive 73/23/EEC Emission of interference EN 50081-2 Immunity to interference EN 50082-2 Characteristic feature - During power or compressed air supply failure the valve adopts a safe position (see table on page 3) - For control function 2 (NO function) please also order throttle 1435DR_Z Air output Air consumption (when idle) Main functions Control function · Normally closed · Normally open · Double acting · Automatic initialisation of actuator and positioner · Position standardization Min. Position · Position standardization Max. Position · Close tight function at MIN/MAX POSITION · Linearization function for set value-> Position (linear, 1:25, 1:50, programmable) · Definition of programmable characteristic curve via 11 points Electrical data Power supply Power supply Power consumption Characteristic accuracy 24 V DC ± 10% ≤ 7.2 W (during operation) ≤ 2.4 W (when idle) ≤1% Input / output signals Input signals Input resistance Position feedback Binary outputs (24 V DC / 0.5 A) Permissible minimum stroke a) 0-10V; b) 0/4...20 mA a) 10 kΩ; b) 50 Ω 0-10 V; 4...20 mA (optional) 2 alarm outputs 1 error message output 3 mm Electrical connections Standard Power supply Input signal Travel sensor Recommended diameter of connection cable Terminals Cross section of wire For details see parameter table of operating instructions Materials 5 - 10 mm WAGO 236 0.5 ... 2.5 mm² AWG 20 ...12 M12 plug, 5-pin M12 plug, 5-pin M12 socket, 5-pin Ambient temperature 0 to 60°C -20 to 60°C with heating element (≤ 25 W @ 24 V DC) Storage temperature 0 to 60°C Control medium Dust content Quality classes to DIN ISO 8573-1 Class 3 max. particle size 5 μm) (max. particle density 5 mg/m³) Class 4 (max. pressure dew point 3 °C) Class 3 (max. oil concentration 25 mg/m³) 0 - 6 bar Oil concentration Air supply 1435 Aluminium, epoxy coated PMMA PMMA Travel sensor Anod. Alu PEEK PAI NBR } linear design turn } quarter design Travel sensor Operating conditions Pressure dew point Housing Display cover Key cover M16 cable entry M16 cable entry M12 cable entry Optional Power supply, alarm outputs Input / output signals Travel sensor 50, 90 Nl/min, dependent on type (PZ = 6 bar) 0 Nl/min Linear design Mounting Stroke Resistance R Connection Remote 0-30 / 0-50 / 0-75 mm 3 / 5 / 5 kΩ Pre-fitted cable (max. 20 m) Quarter turn design Mounting Angle of rotation Resistance R Connection Remote 0-93° 3 kΩ Pre-fitted cable (max. 20 m) Additional diagnostics from version index 01 Available in ”Advanced” system mode - Diagnostic functions - 3 parameter sets can be saved and reloaded - 3 user levels (access authorization) - Operating hours counter - Event list (For details see operating instructions) 2 Safety function Type of error Outlet A1 Outlet A2 Electrical power supply failure Single acting: vented Double acting: vented Single acting: non existent Double acting: pressurized Pneumatic supply failure Single acting: vented Double acting: not defined, depending on the operating options of the actuator Single acting: non existent Double acting: not defined, depending on the operating options of the actuator The safety function is not a substitute for specific plant safety requirements Order data - Positioner Field bus Without Accessory Accessory Action Code Code Z Code 1 Double acting 3 Without explosion-proof rating Code Without 000 Single acting Explosion-proof class Options 0 Electrical connections M12 5-pin 1* 4-20 mA actual value output 2 4-20 mA actual value output Electrical connections M12 5-pin 3* 4-20 mA actual value output and heating element 4 Electrical connections M12 5-pin and heating element 5* Heating element 6 4-20 mA actual value output, electrical connections M12 5-pin and heating element 7* * Versions with M12 connections: Order suitable cable sockets / plugs (see page 11) Version Code 0 Electro-pneumatic 4-20 mA, 50 l/min 01 Electro-pneumatic 4-20 mA, 90 l/min only for action code 1 (single acting) 02 Order example 1435 Type 1435 Field bus (code) Code 000 Z 1 0 0 01 000 Accessory (code) Z Action (code) 1 Explosion-proof class (code) 0 Options (code) 0 Version (code) 01 3 1435 Parts required for direct mounting Linear actuators Quarter turn actuators GEMÜ 1435... (positioner) GEMÜ 1435... (positioner) GEMÜ 1445 000 Z... (mounting kit for travel sensor) GEMÜ 1445 000 Z... (mounting kit for travel sensor) GEMÜ 1440... (air connections) GEMÜ 1440... (air connections) GEMÜ 1219... (cable socket - cable plug M12)* GEMÜ 1219... (cable socket - cable plug M12)* Note: Mounting kit 1445 000 Z... (plastic spindle, spring, threaded adapter, if applicable) depends on the valve type. Please order separately specifying valve type, DN and control function. Please order air connections 1440 (fittings for 6 mm tube) if required, (double acting = 2x). * Versions with M12 connections: Order suitable cable sockets / plugs (see page 11) Order data - Mounting kits for direct mounting - Linear actuators Direct mounting: with mounting bracket GEMÜ 1445 000 Z 10* Order example 1445 Type 1445 Field bus (code) Z 10 000 Accessory (code) Z Mounting kit (code) 10* Note: The mounting kit 1445 000 Z... includes the travel sensor and the mounting parts. Please order air connections 1440 (fittings for 6 mm tube) if required, (double acting = 2x) 1435 000 4 Order data - Mounting kits for direct mounting - Quarter turn actuators GEMÜ 1445 000 Z 00... GEMÜ 1445 000 Z 60...V Mounting: Mounting bracket Mounting: NAMUR adapter V Field bus Without Accessory 000 Version Code AT (Control connection “OPEN“ left) AT IA (Control connection “OPEN“ right) IA Mounting kit Version IA Code Hole spacing Shaft height 80 x 30 80 x 30 130 x 30 80 x 30 130 x 30 130 x 30 AT Code Z Mounting: NAMUR adapter H NAMUR size (VDI/VDE) Code Accessory GEMÜ 1445 000 Z 60...H Code 20 30 50 20 30 50 01 02 04 01 03 04 NAMUR adapter Code Mounting bracket 00 Adapter V V NAMUR adapter V/H 60 Adapter H H Order example 1445 Type 1445 Field bus (code) 000 Z AT 60 01 H 000 Accessory (code) Z Version (code) AT Mounting kit (code) 60* NAMUR size (VDI/VDE) (code) 01 NAMUR adapter (code) H Note: The mounting kit 1445 000 Z... includes the travel sensor and the mounting parts. Please order air connections 1440 (fittings for 6 mm tube) if required, (double acting = 2x) 5 1435 Parts required for remote mounting Linear actuators Quarter turn actuators GEMÜ 1435... (positioner) GEMÜ 4232... (travel sensor) GEMÜ 4232 S01 Z... (mounting kit for travel sensor) GEMÜ 1440... (air connections) GEMÜ 1445 000 Z MP (mounting bracket) GEMÜ 1219... (cable socket - cable plug M12)* GEMÜ 1435... (positioner) GEMÜ 4231... (travel sensor) GEMÜ 4231 S01 Z... (mounting kit for travel sensor) GEMÜ 1440... (air connections) GEMÜ 1445 000 Z MP (mounting bracket) GEMÜ 1219... (cable socket - cable plug M12)* Note: Mounting kit 4232 S01 Z.../4231 S01 Z... (threaded adapter, if applicable, ...) depends on the valve type. Please order separately specifying valve type, DN and control function. Please order air connections 1440 (fittings for 6 mm tube) if required, (double acting = 2x). * Versions with M12 connections: order suitable cable sockets/plugs (see page 11) Order data - Mounting kits for remote mounting - Linear actuators GEMÜ 4232 (travel sensor) GEMÜ 4222 S01 (mounting kit for travel sensor) Field bus Without Accessory Accessory Code Travel 000 Code Code Potentiometer, 30 mm length 030 Potentiometer, 50 mm length 050 Potentiometer, 75 mm length 075 Cable length Z Code Length 2.0 m 02M0 Length 5.0 m 05M0 Others on request Housing material Code Cable connection Code PP coated 05 Open wires with multicore cable ends 0000 Aluminium, black anodized 14 M12 cable plug, straight, 5-pin, plastic 4001* PVDF coated (suitable for High Purity) 20 * required for positioner version with M12 5-pin electrical connections Order data 4232 Type Field bus (code) Accessory (code) Housing material (code) Travel (code) Cable length (code) Cable connnection (code) 4232 000 000 Z Z 14 14 030 030 05M0 05M0 0000 0000 Note: Mounting kit 4232 S01 Z... ( plastic spindle, spring, threaded adapter, if applicable) for travel sensor 4232 dependent on valve type. Please order separately with specification of valve type, DN and control function. Please order air connections 1440 (fittings for 6 mm tube) if required (double acting = 2x) 1435 6 Order data - Mounting kits for remote mounting - Quarter turn actuators GEMÜ 4231 (travel sensor) GEMÜ 4231 S01 (mounting kit for travel sensor) Field bus Without Accessory Accessory Housing material PAI Travel Code Cable length 000 Code Code Length 2.0 m 02M0 Length 5.0 m 05M0 Others on request Z Code Cable connection XF Code Potentiometer, 90° 090 Order example 4231 Type 4231 Code Open wires with multicore cable ends 0000 M12 cable plug, straight, 5-pin, plastic 4001* * required for positioner version with M12 5-pin electrical connections 000 Field bus (code) Z XF 090 05M0 0000 000 Accessory (code) Z Housing material (code) XF Travel (code) 090 Cable length (code) 05M0 Cable connnection (code) 0000 Note: Mounting kit 4231 S01Z... (distance piece, mounting bracket) dependent on valve type. Please order separately with specification of valve type, DN and control function. Please order air connections required for positioner version with M12 5-pin electrical connections 1440 (fittings for 6 mm tube) if required (double acting = 2x) 7 1435 Positioner dimensions [mm] Rear view Front view Side view (from left) Side view (from right) Side view (from top) Side view (from below) Legend A1: Pneumatic outlet A1 (connection for single acting actuators) A2: Pneumatic outlet A2 (connection for double acting actuators) P: Air supply inlet 1435 R: D1: D2: RV: Exhaust Throttle D1 acts on A1 Throttle D2 acts on A2 Check valve 8 Dimensions - GEMÜ 4232 travel sensor for linear actuators Direct und remote mounting [mm] Travel x (Stroke in mm) 30 62,2 50 84,2 75 109,2 Pre-fitted cable lengths for remote mounting: 2 m, 5 m up to max. 20 m Stroke Dimensions - Mounting bracket GEMÜ 1445 for wall mounting of positioner Remote mounting [mm] Mounting bracket for wall mounting of positioner Order no. 1445 000 Z MP Please order mounting bracket and travel sensor separately, see following pages. Dimensions - Travel sensor GEMÜ 4231 for quarter turn actuators incl. bracket Direct und remote mounting [mm] Shaft height WH Hole spacing D A B C 20 30 50 80 80 130 40 50 70 59 69 89 100 100 150 9 1435 Electrical connection - Standard version Legend 10 V X ┴ IW+ IWUW+ UWX+ XGND 24V or gn bl gr A1 A2 ERR orange green blue grey ┴ green brown white Connection of external travel sensor system Set value input 0 / 4-20 mA Set value input 0 - 10 V Actual value output 0 - 10 V 4-20 mA (optional) - internal supply Supply voltage 24 V DC Potential - earth Alarm 1 Alarm 2 Error message output GND out Electrical connection - M12 (optional) X1 X2 X3 Connection X1 A-coded M12 plug Connection X2 A-coded M12 plug Connection X3 A-coded M12 socket 1435 Pin 1 2 3 4 5 Ctr I O I O O Signal name Uv, 24V DC supply voltage Uo, Error message output, 24V DC Uv, GND supply voltage Uo, Alarm output 1, 24V DC Uo, Alarm output 2, 24V DC Pin 1 2 3 4 5 Ctr I I O O X Signal name IW+, Set value input 0 / 4-20 mA IW-, Set value input 0 / 4-20 mA X+, Actual value output 10 V / 4-20 mA X-, Actual value output 0 - 10 V / 4-20 mA n.c. Pin 1 2 3 4 5 Ctr O I O X X Signal name Uv, Actual value supply 10V DC Usig, Actual value input 0 - 10V DC Uv, Actual value supply GND n.c. n.c. 10 Accessories Siutable M12 cable sockets for GEMÜ GEMÜ 1435 Order code Designation Material 1219000Z03 00DG 00M0M125A M12 cable socket, straight, 5-pin Connector without cable Plastic 1219000Z03 00DW 00M0M125A M12 cable socket, angle, 5-pin Connector without cable Plastic 1219000Z00 00DG 00M0M125A M12 cable socket, straight, 5-pin Connector without cable Brass, nickel-plated 1219000Z00 00DW 00M0M125A M12 cable socket, angle, 5-pin Connector without cable Brass, nickel-plated 1219000Z02 00DG 00M0M125A M12 cable socket, straight, 5-pin Connector without cable Stainless steel 1219000Z02 00DW 00M0M125A M12 cable socket, angle, 5-pin Connector without cable Stainless steel 1219000Z03 00DW 02M0M125A M12 cable socket, angle, 5-pin Pre-fitted with 2M PUR cable, black Plastic 1219000Z00 00DG 02M0M125A M12 cable socket, straight, 5-pin Pre-fitted with 2M PUR cable, black Brass, nickel-plated 1219000Z00 00DW 02M0M125A M12 cable socket, angle, 5-pin Pre-fitted with 2M PUR cable, black Brass, nickel-plated 1219000Z00 00DG 05M0M125A M12 cable socket, straight, 5-pin Pre-fitted with 2M PUR cable, black Brass, nickel-plated 1219000Z00 00DW 05M0M125A M12 cable socket, angle, 5-pin Pre-fitted with 2M PUR cable, black Brass, nickel-plated 1219000Z00 00DW 10M0M125A M12 cable socket, angle, 5-pin Pre-fitted with 2M PUR cable, black Brass, nickel-plated 1219000Z02 00DW 10M0M125A M12 cable socket, angle, 5-pin Pre-fitted with 2M PUR cable, black Stainless steel 1219000Z00 00SG 00M0M125A M12 cable plug, straight, 5-pin for travel sensor 4231/4232 Brass, nickel-plated External throttle for control function 2 (spring opening) Order no. 1435DR6Z Mounting kit GEMÜ 1445 S01... Mounting kit GEMÜ 4231 S01... Mounting kit GEMÜ 4232 S01... (Spindle + mounting parts) 11 1435 Mounting examples GEMÜ 550 metal globe valve with GEMÜ 1435 ePos Direct mounting GEMÜ 690 plastic diaphragm valve with GEMÜ 1435 ePos GEMÜ 512 metal globe valve with GEMÜ 1435 ePos For further positioners, accessories and other products, please see our Product Range catalogue and Price List. Contact GEMÜ. VALVES, MEASUREMENT AND CONTROL SYSTEMS GEMÜ Gebr. Müller · Apparatebau GmbH & Co. KG · Fritz-Müller-Str. 6-8 · D-74653 Ingelfingen-Criesbach · Tel. +49 (0) 7940/123-0 · Telefax +49 (0) 7940/123-224 e-mail: [email protected] · http://www.gemue.de Subject to alteration · 09/2007 · 88101193 GEMÜ 650 metal diaphragm valve with GEMÜ 1435 ePos Should there be any doubts or misunderstandings, the German version of this data sheet is the authoritative document! Technical data sheet Remote mounting
Similar documents
1435 ePos - Gemu Group
- Linearization function for set value -> Position (linear, 1:25, 1:50, freely programmable) - Definition of programmable characteristic curve via 11 points For details see parameter table of...
More informationMeasuring Supports and Auxiliary Equipment
INTERAPID Magnetic Support with Flexible Arm For measurements in hard to reach locations. Instant and reliable locking through
More information