Model S2 - LABRepCo
Transcription
Model S2 - LABRepCo
www.biometra.com Model S2 Sequencing Gel Electrophoresis System • Produces a 30 cm x 40 cm gel that fits easily on a standard 14 in x 17 in X-ray film • Integral aluminum plate for even heat distribution to minimise band curvation (“smiling”) • Removable lower buffer tray with a separate chamber for collecting the buffer from the upper reservoir, eliminating the need to move the apparatus for buffer disposal • Built-in integral clamps hold the gel in place • Unique gasket sealing system ensures leak-free operation without grease or notched plates • Safety interlock lids • Additional combs and apparatus components available separately The Model S2 Sequencing Gel Electrophoresis Apparatus is designed for vertical polyacrylamide gel separations of oligo- and polynucleotides, nucleic acid sequencing, genotyping and polymorphic studies. Gel Casting Clamp Apparatus dimensions (W x D x H) Gel dimensions (W x H) 42.2 cm x 21.6 cm x 44.5 cm 31.0 cm x 38.5 cm Working buffer volume: 1 L Item Order No. Model S2 21105010 (USA) Complete with power cords, four 14 cm 0.4 mm vinyl sharktooth 21105036 (EU) combs, set of 0.4 mm thick vinyl side spacers; pair of glass plates, roll of gel sealing tape; surface temperature monitor Model S2 including gel casting clamp (21105432) 21105499 (USA) 21105481 (EU) DNA sequence analysis performed on the Model S2 System. 8 % polyacrylamide/8.3 M urea gel Tris-borate-EDTA buffer electrophoresed at 1.5 kV for 2.5 h. 70 Ordering Information for Accessories see page 72 - 73 Elect rophoresis Sequencing Model SA Adjustable Sequencing Gel Electrophoresis System • Snap-action section clamps allow quick and easy adjusting of the height • Adjustable levelling feet and built-in levelling indicator ensure consistent and reproducible results • Integral aluminium plate for even heat distribution to minimise “smiling” • Removable lower buffer tray with a separate chamber for collecting the buffer from the upper reservoir eliminating the need to move the apparatus for buffer disposal • Built-in integral clamps hold the gel in place •Unique gasket sealing system ensures leak-free operation • Safety interlock lids •Combs and apparatus components available The Model SA sequencing apparatus is designed for the separation of oligonucleotides, polynucleotides and nucleic acid sequences in vertical polyacrylamide gels. With optional extensions the unit can easily be adjusted to three different heights: 32 cm, 43 cm or 60 cm. Model Apparatus dimensions (W x D x H) Gel dimensions (W x H) SA-32 29 cm x 22 cm x 41 cm 17 cm x 32 cm SA-43 29 cm x 22 cm x 52 cm 17 cm x 43 cm SA-60 29 cm x 22 cm x 68 cm 17 cm x 60 cm Working buffer volume: 500 ml Item Order No. Model SA-32 31096019 (USA) Complete with top and base sections, power cords; two 14 cm vinyl 31096027 (EU) sharktooth combs; set of 0.4 mm thick spacers; pair of glass plates; roll of gel sealing tape; surface temperature monitor. Model SA-43 (one extension) 21105499 (USA) 21105481 (EU) Model SA-60 (one extension) 31096035 (USA) 31096043 (EU) Gel Casting Clamp 31096324 SA Extension (27 cm) 31096076 SA Extension (11 cm) 31096423 DNA sequence analysis performed on the Model SA-60 System. GEL-MIX 6, 6 % SDS-polyacrylamide gel Tris-borate-EDTA buffer electrophoresed at 55 W constant power (2.3 to 2.7 kV) for 3 h. Ordering Information for Accessories see page 72 - 73 71 www.biometra.com Combs for Sequencing Apparatus Shark tooth combs •The teeth form barriers between adjacent lanes for sample loading • Reduced risk of torn or deformed wells cause by square-toothed combs •The minimal space between lanes facilitates accurate reading of sequences • Generate flatter, more uniform loading surface than square-toothed combs Shark tooth combs are ideally suited for facilitating the analysis of sequencing reactions. They are designed for use with all sequencing apparatus models (S2, S2001 and SA). In addition, the combs can be used with all other systems with 0.4 mm spacers. Square tooth combs for model S2001 and S2 Number of wells Comb thickness Volume/well Order No. 16 0.4 mm 25 µl 21035043 16 0.8 mm 50 µl 21035050 16 1.6 mm 100 µl 21035068 20 0.4 mm 19 µl 21035076 20 0.8 mm 38 µl 21035084 20 1.6 mm 76 µl 21035092 32 0.4 mm 10 µl 21035100 32 0.8 mm 20 µl 21035118 32 1.6 mm 40 µl 21035126 Sample application. Shark tooth combs for all models 72 Comb length Comb thickness Number of teeth Volume/well Pcs./Pckg. Order No. 14 cm 0.4 mm 25 2 – 4 µl 6 21045018 28 cm 0.4 mm 50 2 – 4 µl 2 21046016 14 cm 0.4 mm 49 1 – 2 µl 4 21045026 14 cm 0.19 mm 25 2 – 4 µl 6 21105317 14 cm 0.35 mm 25 2 – 4 µl 6 21105341 28 cm 0.35 mm 62 2 – 4 µl 2 21035134 Elect rophoresis Sequencing Combs for Sequencing Apparatus Order Information Square tooth combs for model SA Number of wells Comb thickness Volume/well Order No. 3 0.4 mm 240* µl 11092012 3 0.8 mm 480* µl 11092020 3 1.6 mm 960* µl 11092038 12 0.4 mm 15 µl 11092061 12 0.8 mm 30 µl 11092079 12 1.6 mm 60 µl 11092087 18 0.4 mm 8 µl 11092095 18 0.8 mm 16 µl 11092103 18 1.6 mm 32 µl 11092111 * Central, preparative well Accessories Item Dimensions Content Order No. Spacer set for Model S2001/S2 0.19 mm 2 Spacer, 12 End blocks 21105309 Spacer set for Model S2001/S2 0.35 mm 2 Spacer, 12 End blocks 21105366 Spacer set for Model S2001/S2 0.4 mm 2 Spacer, 12 End blocks 21108014 Spacer set for Model S2001/S2 0.8 mm 2 Spacer, 12 End blocks 31109010 Spacer set for Model S2001/S2 1.6 mm 2 Spacer, 12 End blocks 31109028 Wedge spacer for Model S2001/S2 0.4 – 1.2 mm 2 Spacer 21107016 Wedge spacer for Model SA-32 0.4 – 1.2 mm 2 Spacer 21093083 Wedge spacer for Model SA-60 0.4 – 1.2 mm 2 Spacer 21093133 End spacer for Model S2001/S2 0.4 mm 1 Spacer 21105077 End spacer for Model S2001/S2 0.8 mm 1 Spacer 21105069 End spacer for Model S2001/S2 1.2 mm 1 Spacer 21105325 End spacer for Model S2001/S2 1.6 mm 1 Spacer 21105051 12 Pieces 21965017 Spacer silicon blocks 12 Pieces 21105382 Glass plate set for S2001/S2 33 cm x 39 cm 2 Plates 11034014 Glass plate set for SA-32 19.7 cm x 33.8 cm 2 Plates 21093067 Spacer foam blocks Glass plate set for SA-60 2 Plates 21093117 Gel casting clamp for S2001/S2 1 Piece 21105432 Gel casting clamp for SA-32 1 Piece 31096324 Gel sealing tape 1 Roll 11032018 Gel sealing tape 10 Rolls 11032026 Sealing for buffer chamber S2001/S2 1 Piece 21105358 Sealing for buffer chamber SA 1 Piece 21093034 Top clamp 1 Piece 21047014 Clamps for gel sandwich 12 Pieces 11098019 Clamps for gel sandwich (stainless) 12 Pieces 21105333 Surface temperature monitor strips 3 Pieces 21105358 73 www.biometra.com Gel Casting Clamps • Easy assembly and clean up • Provides a tight, leak-free seal and even pressure over the entire surface •Cast gels from 0.2 to 0.8 mm thickness and wedge gels from 0.4 to 1.2 mm thickness • Gels can be cast from the top or through the bottom port using a syringe or gradient former. The S2/2001 and SA gel casting clamp provides an easy way to cast sequencing gels without the use of tape or binder clamps. 74 Model Glass plate (W x H) Gel (W x H) Order No. Casting clamp for S2/2001 33.0 cm x 39.0 cm 31.0 cm x 39.0 cm 21105432 Casting clamp for SA 19.7 cm x 33.8 cm 17.0 cm x 33.8 cm 31096324 Elect rophoresis Sequencing 75