revista haemostasis.FH11 - Ral-sa

Transcription

revista haemostasis.FH11 - Ral-sa
C
TÉCNICA PARA EL LABORATORIO, S.A.
M
Y
CM
MY
CY CMY
K
The cleverest
and best
system for
haemostasis
Clot line
C
M
Y
CM
MY
CY CMY
K
Introduction
Haemostasys
analysis
HAEMOSTASIS analysis and specially the PLASMATIC PHASE
has deserved special attention in RAL since its foundation
in 1980, it was and still is a priority field.
On January 1969 we began with the presentation of
Fibrometer, an instrument with mechanical detection of the
clot, that was the first step to automatisation. Later, on
1973 we presented the Digiclot Elvi 818 coagulometer with
optical detection of the Clot formation that, together with
Biodynamics, were the up-dated newness technology.
Thanks to the unconditional support of some people that
well know this field, we began on April 1976 the publication
of short divulge notebooks to our customers under the name
of “TEMAS DE HEMOSTASIA” (Haemostasis themes). These
publications were given to the interested people, till June
1979.
Simultaneously, during this period, we have done a lot of
presentations in the main Spanish cities, generally supported
by the local analysts associations, presenting the new
technology and the practice of more advanced methods.
At RAL’s foundation, we agreed as priority to follow the
initial work and spend in R+D to get our own product line,
with high quality to cover the needs of the most demanding
customers, and we still work in this direction.
TÉCNICA PARA EL LABORATORIO, S.A.
Today we offer a whole service
for the HAEMOSTASIS
PLASMATIC PHASE analysis,
based on an instrument line and
complementary reagents too.
Now, and after instruments as TURBICLOT, STIRR CLOT 2000
and CLOT 1 A, we are focusing our line on CLOTTY,
CLOT SP, CLOT 2 B and AUTOCLOT.
C
M
Y
CM
MY
CY CMY
K
Description
Short description
of plasmatic
haemostasis phase
Haemostasis cascade
TÉCNICA PARA EL LABORATORIO, S.A.
Instruments
1
2
Placement of cuvette in measuring cell.
3
Addition of starter reagent (or plasma).
4
Security time (5 seconds).
5
Fibrin polymers formation (clot).
Reset the chronometer.
3 5
Clotting time.
PRINCIPLE OF WORK
C
Clotty
One channel
coagulometer
One channel coagulometer for
automatic detection of Clot
formation by turbodensitometric
principle.
Easy to use and program, including
calibration curves. Microprocessor
built-in-it. Sequential results
obtainment.
TÉCNICA PARA EL LABORATORIO, S.A.
Clot 2B
Dual channel
coagulometer
M
Y
CM
MY
CY CMY
K
C
M
Y
CM
MY
CY CMY
K
Clot SP
One channel
coagulometer
One channel coagulometer
for automatic detection of
Clot
formation
by
turbodensitometric principle.
Memory capacity for 10 test.
Easy to use and program,
including calibration curves.
Printer built-in-it.
Two models: macro and
microcuvettes.
TÉCNICA PARA EL LABORATORIO, S.A.
Dual channel coagulometer for automatic detection of fibrin
formation, under turbodensitometer principle. Consecutive or
dupplicate measurements.
Easy to program, with a capacity of 10 stored methods.
Automatic optical start and stop system.
Mixing procedure during test development, to well homogenise
sample and reagent, and help to detect weak clots.
Possibility to introduce the activity curve obtained by using a
pool of normal local patient’s plasmas.
Calibration curve for Fibrinogen tests.
Deficiency plasmas factors can be studied too.
Two models: macro and microcuvettes.
C
M
Y
CM
MY
CY CMY
K
Autoclot
Automatic
coagulometer
TÉCNICA PARA EL LABORATORIO, S.A.
Turbodensitometric detection principle with LED
technology.
Automatic analysis and calculation of PT, APTT,
Fibrinogen, TT and factor studies.
Automatic calibration of PT and Fibrinogen with
calibrator and samples automatic dilution, when
needed.
Samples are automatically rerun when results do not
fit the programmed range.
Rotor capacity for 32 samples and 32 reaction cuvettes.
Reagents compartment for 6 vials.
Washing and deproteinizant compartment.
Probe with level detection.
Throughput: 50 PT or Fibrinogen per hour. 25 APTT
per hour.
Macro and microcuvettes.
C
M
Y
CM
MY
CY CMY
K
Reagents
1 Quick test- PT
GN 1015
GN 1011
HEMOPLASTIN L
HEMOPLASTIN L
ISI 1.0-1.3
ISI 1.0-1.3
6 x 5 ml
6 x 10 ml
2 APTT test
GN 1033
GN 1030
GN 1031
GN 1080
GN 1060
GN 1081
HEMOS PTT KIT
3 + 3 x 4 ml
Ellagic Acid + Calcium chloride
HEMOS PTT KIT
3 + 3 x 10 ml
Ellagic Acid + Calcium chloride
HEMOSPTT - Ellagic Acid
6 x 4 ml
Calcium chloride
6 x 4 ml
HEMOSPTT - Ellagic Acid
6 x 10 ml
Calcium chloride
6 x 10 ml
3 Fibrinogen test
GN 1045
GN 1145
HEMOFIBRIN
5 x 2 ml + 125ml + 1ml
Bovine Thrombin + Imidazole Buffer + Calibrator
HEMOFIBRIN L
5 x 2 ml + 125ml + 1ml
Bovine Thrombin + Imidazole Buffer + Calibrator
4 Control plasmas
GN 1100
GN 1200
HEMOTROL N
HEMOTROL P
6 x 1 ml
6 x 1 ml
Gernon liquid
reagents line
C
M
Y
CM
MY
CY CMY
K
TÉCNICA PARA EL LABORATORIO, S.A.
COMPANY CERTIFIED
ISO 13485:2012 / ISO 9001:2008 / ISO 14001:2004
Av. Mare de Déu de Montserrat, 51 - 08970 Sant Joan Despí - Barcelona - Spain
Tel. (+34) 93 480 80 47 - Fax (+34) 93 373 00 92 - e-mail: [email protected] - www.ral-sa.com

Similar documents

North America Clot Management Devices Market Size, Application Analysis, Regional Outlook, Competitive Strategies and Forecasts to 2020

North America Clot Management Devices Market Size, Application Analysis, Regional Outlook, Competitive Strategies and Forecasts to 2020 The new report, North America Clot Management Devices Market Outlook to 2021, provides key market data on the North America Clot Management Devices market. The report provides value, in millions of US dollars, volume (in units) and average price data (in US dollars), within market segments - Peripheral Venous Thrombectomy Devices and Embolectomy Balloon Catheters.

More information