GSE Lining Technology GmbH
Transcription
GSE Lining Technology GmbH
GSE Lining Technology GmbH Landfill Landfill Content • Landfill Design • Landfill Detail • Slope Design – Orientation • Product GSE Liner and GSE Liner MRS / DRS • Shipment • Installation • Colortex Landfill Grass ≥50cm Drainage layer Protection layer Geomembrane ≥2,5mm ≥50cm Sub grade Combination sealing Subsoil ≥30cm Clay lining ≥100cm Waste Drainage layer Drainage pipe Protection layer Geomembrane ≥2,5mm ≥75cm ≥30cm Standard Landfill Design – German Regulation Tasi Clay lining Leveling layer Waste Basis Capping Landfill Plan View - Details Trench Toe Fixation Mechanical Fixation-Attachment Pipe Penetration Mechanical Fixation-Embedded Landfill Trench - Detail Anchor Trench with backfill or sand B A 150 R 1000 R1 000 C 50 R2 300 Pit Covering see 2500.02.01 or 2500.03.01 GSE Liner HD Sand layer, d=100 Rough grading A [m ] B [m ] C [m ] < 10 0 ,6 0 0 ,6 0 10 - 40 1 ,0 0 ,8 0 1 ,5 0 1 ,0 > 40 Landfill Pipe Penetration - Detail Landfill 30 148 74 Embedded Fixation - Detail GSE Liner HD 74 Extrusion weld 23 3S-Profile 74 23 74 148 3-S-Profile Landfill Attachment Fixation - Detail Sealing Strip Flat Steel Bar, Stainless Steel Hilti-Impact Anchor (e.g. HPS 8/12) GSE Liner HD Batten System Landfill Toe Fixation - Detail Landfill Slope Design - Orientation GSE Liner HD GSE Liner MRS / DRS Geotextile Geotextile GSE Liner HD GSE Liner HD MRS / DRS Geotextile 17° 31° 1:3,3 1:1,7 GSE Liner HD MRS / DRS GSE Liner HD Clay Clay Clay 34° 17° 1:3,3 1:1,5 Landfill GSE HD or GSE HD MRS / DRS Property Unit Test Method Thickness mm DIN EN ISO 2286-3 1,0 1,5 2,0 2,5 3,0 Density g/cm³ DIN 53479-A ≥ 0,94 ≥ 0,94 ≥ 0,94 ≥ 0,94 ≥ 0,94 Tensile Properties (each direction) •Strength at Break •Strength at Yield •Elongation at Break •Elongation at Yield MPa MPa % % Io = 50 mm / 33 mm Io = 50 mm / 33 mm ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 Tear Resistance (each direction) N DIN 53515 ≥ 135 ≥ 200 ≥ 270 ≥ 335 ≥ 400 Puncture Resistance N FTMS 101, Method 2065 ≥ 220 ≥ 330 ≥ 440 ≥ 550 ≥ 660 Carbon Black Content % ASTM D 1603 ≥2 ≥2 ≥2 ≥2 ≥2 ASTM D 5596-94 cat. 1-2 cat. 1-2 cat. 1-2 cat. 1-2 cat. 1-2 Carbon Black Dispersion Nominal Value Dimension Stability (each direction) % DIN 53377, 120ºC, 1h ≤2 ≤2 ≤2 ≤2 ≤2 Environmental Stress Crack Resistance h ASTM D 1693, Cond. B ≥1500 ≥1500 ≥1500 ≥1500 ≥1500 Oxidative Induction Time min ASTM D 3895, 200ºC ≥100 ≥100 ≥100 ≥100 ≥100 Landfill Shipment Smooth MRS / DRS 1,0 1,5 2,0 2,5 1,0 1,5 2,0 2,5 15 15 15 15 9 15 15 15 Area m² 1500 975 750 600 1500 750 600 487,5 Weight tons 22,5 22,5 22,5 22,5 22,5 22,5 22,5 22,5 # Roll Landfill Installation - Unrolling Device • 1,5 ton Roll • Handling friendly Landfill Installation - Anchor Trench Landfill Installation on Slope • Loading Equipment Landfill Installation on the Bottom-Unrolling • Subgrade Control • Geomembrane Appearance Landfill Installation on the Bottom-Overlap • Protecting Strip for Welding • Wind Load Protection Landfill Installation – Hot Wedge Welding • Clean Surface • Constant Overlap Width Landfill Installation – Hot Wedge Welding • Roll Pressure • Temperature • Speed Landfill Installation – Hot Wedge Welding Air Pressure Testing • 10 Minutes • Pressure depends on Temperature • 10% Pressure Drop Landfill Installation – Extrusion Weld • Removal of Oxidation Layer Landfill Installation – Extrusion Weld • Granulat • Welding Rod • Same Raw Material Landfill Installation - Extrusion Weld Vakuum Box Testing • Soap • 0,5 Bars • 10 Seconds • Bubble Formation Landfill Installation - Drainage System Landfill Installation - Covering • Geotextile for Protection • Drainage Layer • No heavy Equipment Landfill Colortex - Application • Esthetic • Total covered area • Quality smooth geomembrane Landfill Colortex Properties Property Unit Test Method Thickness mm DIN EN ISO 2286-3 1,0 1,5 2,0 2,5 Density g/cm³ DIN 53479 ≥ 0,94 ≥ 0,94 ≥ 0,94 ≥ 0,94 Tensile Properties (each direction) •Strength at Break •Strength at Yield •Elongation at Break •Elongation at Yield MPa MPa % % Io = 50 mm Io = 50 mm ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 ≥ 26 ≥16 ≥700 ≥10 Tear Resistance (each direction) N DIN 53515 ≥ 135 ≥ 200 ≥ 270 ≥ 335 Puncture Resistance N FTMS 101, Verfahren 2065 ≥ 220 ≥ 330 ≥ 440 ≥ 550 Carbon Black Content % ASTM D 1603 ≥2 ≥2 ≥2 ≥2 ASTM D 3015 cat. 1-2 cat. 1-2 cat. 1-2 cat. 1-2 Carbon Black Dispersion Nominal Values Dimension Stability (each direction) % DIN 53377, 120ºC, 1h ≤2 ≤2 ≤2 ≤2 Environmental Stress Crack Resistance h ASTM D 1693, Cond. B ≥ 1500 ≥ 1500 ≥ 1500 ≥ 1500 Landfill Colortex – Product Description Green Army Yellow Sand Green Grass Blue Lagoon Your Contact at GSE European Headquarters GSE Lining Technology GmbH Großmoorring 4 D-21079 Hamburg Tel: 0049 40 76742-0 Fax: 0049 40 76742-34 E-Mail: [email protected] 20.12.2002
Similar documents
GSE TunnelLiner
GSE TunnelLiner Table of Content • Product Description • Application - Open Trench - Bored Tunnel • Installation • Accessories • Certification • References
More information