This document MUST be forwarded to your architect or building
contractor to ensure that the site is prepared correctly as any
mistakes could be extremely costly.
Pre-Installation Document
Interbath
General Site Requirements.
The wall decoration and floor covering must be complete and finished.
Positioning and fixing the unit.
The Interbath stands on and is secured to the floor. Floors must have sufficient depth in
order to receive 50mm long anchors.
Under-floor heating CANNOT be laid under the bath area.
Adjacent walls need to be plumb, flat and clear of obstructions up to 1220mm above the
floor. Skirting boards may be left in place.
Fig 1
If the unit is to be installed in an alcove or into a corner the side wall/walls will also have
to be clear for a height of 1220mm.
The bath can be fitted as a Corner unit, Peninsular unit or an Island unit.
In all configurations a minimum clearance of 850mm must be left on the door side for
access.
A minimum clearance of 40mm is required against any adjacent walls (WG & LWG) and
fixed appliances (FG) including toilets, radiators, sinks and shower units.
Note: If the bath(corner fitting) is ordered with neatfold stretcher, the gap at
the long side of the bath (LWG) would have to be 65mm.
If a Peninsular or Island layout is required with a neatfold stretcher there
must be enough clearance for the stretcher to swing and fold to the side of the
bath, 400mm minimum on the opposite side to the door.
Fig 1
LWG
FG
WG
Bath length
Page 850mm
FG
Positioning and fixing the unit - Continued
Fig 2,2a and 2b
When calculating the footprint of the bath use the diagram below and ensure the
clearances are provided at the ends and at the sides.
The red shaded areas must be kept clear of any pipework, wiring or underfloor heating
above and below the floor.
The floor must be strong enough (especially in the foot areas) to carry the weight of the
bath when full and occupied.
NOTE: Floors must be flat and level in the area where the bath is to be installed.
If this is not possible Astor Bannerman MUST be informed prior to installation.
Fig 2
Available bath lengths
1710/1910/2110/2310mm
Bath length 1710 = 660mm
Bath length 1900+ = 890mm
40 mm minimum clearance at each end
290mm
40 mm minimum clearance at each side
Indicates electrical outlet
=
=
No obstructions can be
laid in these areas
800 540
mm mm
Hot and cold ball type
isolation valves and 40mm
waste to be fitted in the
green area
250
mm
CL
1050mm
760mm
1220 mm
470mm
1
280mm min
240
mm
180mm
2
3
25min
Fig 2a
Fig 2b
50mm
Anchor depth
290mm
6 anchors in each footplate
540mm
Each footplate is fixed to the floor as
shown.
Page Plumbing Options
Fig 3
The plumbing options and the outlet positions of the water and waste services must be at
the tap end of the bath.
22mm ball type isolation valves (V) should be positioned and orientated exactly as shown
but can be fed through the wall, floor or along the wall from either side. See Fig 5.
Fig 3
View looking
from tap end
220mm Centres
=
=
V
200mm
Floor to
Centre
H
C
W
Fig 4
A 40mm waste pipe (W) is required and should be positioned and orientated exactly as
shown but can be fed through the wall, floor or along the wall from either side.
Fig 4
Through Floor Waste Option
125mm wall to centre
of 40mm waste pipe
Through Wall Waste Option
100mm wall to end of
40mm waste pipe
100mm wall to
end of valve
VALVE
H
VALVE
C
Page Plumbing Options Continued.
Fig 5 and 6
If the water sevice pipes need to be fitted along the wall from a side wall they need to be
kept tight against the wall.
The water service pipes can be offset vertically (V and Vo) providing the centre of the top
pipe is no more than 200mm from the floor.
If the waste is to be fed along the the wall from a side wall it must be kept tight to the
wall and be positioned below the water service pipes.
The 40mm waste pipe can be fed through the wall (WW) or floor (WF) as shown and cut
to the lengths indicated.
Fig 5
Fig 6
2 different waste options
WW
V
SW
100mm
Vo
WF
200mm
VALVE
100mm
VALVE
125mm
SF
15mm
REDUCER
22mm
Note: If the site piping is
15mm then this should be
expanded to 22mm piping
at the valve end to
accommodate the valves.
VALVE
Tap Options
The Interbath can be supplied with various tap/mixer sets.
The minimum water pressure on each supply must be 1 bar and a maximum of 10 bar
with a differential of no more than 5 bar. Equal Pressures are recommended.
Page Electrical Connection.
Fig 7 & 8
The bath requires a 1 off 230 volt, 1.25kW, waterproof flex outlet, located at any of the
positions shown and supplied from a protected fused spur.
Fig 7
A waterproof surface mounted,
protected flex outlet with a
20mm gland fitted at the bottom
is required in one of the
positions shown
100mm
180mm
Fig 8
180mm
100mm
Page Technical Information.
Electrics
A.C. Input 220 - 240V~, 50/60Hz, 1.25kW Maximum.
DC Output, 24v, 8 Amps.
Safe Working Load
300 Kilograms
Test Load
375 Kilograms
Length
1725mm.
1925mm.
2125mm.
2325mm.
1805mm
2005mm
2205mm
2405mm
Width
800mm
required
required
required
required
to
to
to
to
provide
provide
provide
provide
minimum
minimum
minimum
minimum
clearance.
clearance.
clearance.
clearance.
1690mm required to provide minimum clearance
including the clearance for the door.
Height Range
760mm Minimum
1220mm Maximum.
Bath Water Capacity
Interbath 170
Interbath 190
Interbath 210
Interbath 235
230
256
283
317
litres
litres
litres
litres
to
to
to
to
the
the
the
the
overflow.
overflow.
overflow.
overflow.
Water Pressures
A Minimum of 1 bar is required on both Hot and Cold water supplies.
Maximum 10 bar.
Maximum differential between Hot and Cold 5:1.
NOTE:
If the Interbath is ordered with an additional waste outlet then an
View looking
extra
from waste
tap endpipe is required (DW). The two waste pipes should be positioned
50mm either side of the centreline of the bath orientated as shown for a single
waste pipe. 220mm Centres
=
=
V
200mm
Floor to
Centre
C
H
DW