Standard Arborist Plan Details
Transcription
Standard Arborist Plan Details
CITY OF ALPHARETTA, GEORGIA LANDSCAPE STANDARDS INDEX L-1 TREE PLANTING (TYPICAL SECTION) L-2 TREE ANCHORING - TYPE A (FOR TREES LARGER THAN 2 INCHES CALIPER) L-3 TREE ANCHORING - TYPE B (FOR TREES UP TO 2 INCHES CALIPER) L-4 TREE ANCHORING - TYPE C (FOR CONTAINER GROWN TREES OR B&B TREES UP TO 2 INCHES CALIPER) L-5 TREE PLANTING IN PARKING LOTS (TYPICAL SECTION) L-6 L-7 L-8 TREE PROTECTION / L.O.D. FENCING SHRUB PLANTING BED ROOT BARRIER DETAIL (FOR PUBLIC SIDEWALKS OR CURBING) L-9 L-10 TREE PROTECTION - WOOD SLATS TREE WELL IN BRICK SIDEWALK TREE GRADING CUE CARD (PROVIDED BY ROOTS PLUS FIELD GROWERS ASSOCIATION OF FLORIDA) COVER SHEET 08/01/2015 BY REVISION DATE INDEX CROWN SET AND MAINTAIN IN A PLUMB VERTICAL POSITION. PRUNE ALL DEAD, DAMAGED OR CROSSING BRANCHES AND ALL WATERSPOUTS AND SUCKERS. DO NOT CUT CENTRAL LEADER OR OTHER BRANCH TIPS. WATER RING USE ONLY IF TREES ARE TO BE HAND WATERED WITH A HOSE. BUILD NO HIGHER THAN 3" AND PLACE JUST BEYOND ROOT BALL. DESTROY AFTER ONE GROWING SEASON. ORGANIC MULCH 2" TO 4" DEEP TO LIMITS OF CULTIVATED AREA. KEEP 2" AWAY FROM TRUNK. PLANTING HOLE ROOT BALL DIG ONLY DEEP ENOUGH TO HAVE TOP OF ROOT BALL AT GRADE OR 2" HIGHER IN HEAVY OR POORLY DRAINED REMOVE ALL STRAPPING. CUT AND REMOVE AT LEAST TOP 2 RINGS OF WIRE BASKET. CUT AND REMOVE AT LEAST TOP 12" OF BURLAP. CUT ENCIRCLING ROOTS (CONTAINER-GROWN TREES). SCARIFY IF NECESSARY. SET ROOT BALL ON SOLID GROUND. TILLED SOIL COMPACTED SUBGRADE PLANTING HOLE 3x THE DIAMETER OF THE ROOT BALL TREE PLANTING (TYPICAL SECTION) 08/01/2015 BY REVISION DATE STD. L-1 STAKES ATTACHMENT HEIGHT 2"x2" WOODEN STAKES OR METAL ANCHORS. CUT STAKES LONG ENOUGH FOR SECURE GRIP IN SUBGRADE. ANGLE ATTACH IN A BRANCH CROTCH APPROXIMATELY 1/3 THE HEIGHT OF THE MAIN STEM, OR AT FIRST AVAILABLE BRANCH CROTCH ABOVE THAT POINT. USE 3 STAKES PLACED EQUAL STRAPS STAKES MAY BE NECESSARY FOR TREES GREATER THAN 4" CALIPER. WIDE, SOFT, FLEXIBLE MATERIAL MANUFACTURED FOR THE PURPOSE OF TREE ANCHORING SUCH AS WOVEN POLYPROPYLENE WEBBING OR RUBBER STRIPS WITH GROMMETS FOR WIRE ATTACHMENT. DO NOT USE HOSE AND WIRE. USE ANCHORING SYSTEMS ONLY WHERE WIND OR SOIL CONDITIONS MAKE IT NECESSARY OR AS REQUIRED BY CITY ARBORIST. REMOVE AFTER ONE YEAR. TREE ANCHORING - TYPE A (FOR TREES LARGER THAN 2 INCHES CALIPER) 08/01/2015 BY REVISION DATE STD. L-2 STRAPS STAKES WIDE, SOFT, FLEXIBLE MATERIAL MANUFACTURED FOR THE PURPOSE OF TREE ANCHORING. TWO EXAMPLES SHOWN HERE ARE A WOVEN POLYPROPYLENE WEBBING AND A RUBBER STRIP WITH GROMMETS FOR WIRE ATTACHMENT. 2"x2"x5' WOODEN STAKES OR 5' LONG METAL FENCE POSTS. PLACE PERPENDICULAR TO PREVAILING SUMMER WINDS. WEST WIND ATTACHMENT HEIGHT ATTACH AT APPROXIMATELY 1/3 THE HEIGHT OF THE MAIN STEM. USE ANCHORING SYSTEMS ONLY WHERE WIND OR SOIL CONDITIONS MAKE IT NECESSARY. REMOVE AFTER ONE YEAR. TREE ANCHORING - TYPE B (FOR TREES UP TO 2 INCHES CALIPER OR FOR TREES IN BEAUTY STRIPS, SIDEWALK CUTOUTS, PLANTING PITS, ETC.) NOTE: THIS DETAIL MAY BE UTILIZED FOR TREES GREATER THAN 2 INCHES CALIPER WHICH ARE TO BE PLANTED IN BEAUTY STRIPS, SIDEWALK CUTOUTS, PLANTING PITS, AND SIMILAR LOCATIONS WHERE THERE IS NO ROOM FOR STRAPPING AS PER STD. L-2. 08/01/2015 BY REVISION DATE STD. L-3 CROSS STAKES 2"x2" UNTREATED WOOD. CUT STAKES LONG ENOUGH TO PROVIDE STABILITY. ANCHOR STAKES 2"x2" UNTREATED WOOD. CUT STAKES LONG ENOUGH FOR SECURE GRIP IN SUBGRADE. DRYWALL SCREWS - 2-1/2" ROOT BALL USE ANCHORING SYSTEMS ONLY WHERE WIND OR SOIL CONDITIONS MAKE IT NECESSARY. REMOVE AFTER ONE YEAR. TREE ANCHORING - TYPE C (FOR CONTAINER GROWN TREES OR B&B TREES UP TO 2 INCHES CALIPER) 08/01/2015 BY REVISION DATE STD. L-4 GROUND COVER COVER ENTIRE PLANTER AREA WITH 2-4" DEEP ORGANIC MULCH. USE GROUNDCOVER OR SHRUBS ONLY AS SHOWN ON THE CITY OF ALPHARETTA APPROVED LANDSCAPE PLAN (FOR LAND DISTURBANCE PERMIT). BACKFILL PLANTING HOLE EXCAVATE AND BACKFILL ENTIRE PARKING LOT ISLAND WITH A MINIMUM OF 3' DEEP FRIABLE TOPSOIL OR CLEAN CULTIVATED SUBSOIL. TAMP SOIL BENEATH TREE FIRMLY TO PREVENT SETTLING. ROOT BARRIER OPTIONAL. PREVENTS ROOTS FROM GROWING BETWEEN PAVEMENT AND BASE MATERIAL. DRAINAGE SYSTEM AS NEEDED. PERFORATED DRAIN PIPE IN GRAVEL BED CONNECTED TO STORM DRAIN OR FRENCH DRAIN. CURB & GUTTER PAVEMENT BASE SUBGRADE 8'-0" MINIMUM BACK OF CURB TO BACK OF CURB (TOTAL AREA SHALL BE A MINIMUM OF 200 SQ. FT.) TREE PLANTING IN PARKING LOTS (TYPICAL SECTION) 08/01/2015 BY REVISION DATE STD. L-5 FENCE LOCATION 2'-6" 4'-0" AT LIMITS OF CRITICAL ROOT ZONE (CRZ RADIUS = 1.3' PER 1" DBH) OR AS SHOWN ON THE TREE PROTECTION PLAN FENCE POSTS FENCE MATERIAL TYPE "A" 2"x2" WOOD OR METAL STAKE ORANGE LAMINATED SAFETY NETTING 5' O.C. SIGN 2'-6" 4'-0" KEEP OUT TREE PROTECTION AREA PROHIBIDO ZONA PROTECTORA PARA LOS ARBOLES FENCE POSTS FENCE MATERIAL TYPE "B" METAL STAKE OR "U" POST ORANGE LAMINATED SAFETY NETTING WITH WIRE BACKING ("HOG WIRE" - 14 GAUGE, 2"x4" MESH) 5' O.C. SIGN 2'-6" 4'-0" KEEP OUT TREE PROTECTION AREA PROHIBIDO ZONA PROTECTORA PARA LOS ARBOLES FENCE POSTS FENCE MATERIAL TYPE "C" METAL STAKE OR "U" POST ORANGE LAMINATED SAFETY NETTING 5' O.C. 31.2' ACCESS POINT ALL TREE PROTECTION/LOD FENCING MUST HAVE A MINIMUM OF ONE ACCESS POINT EVERY 200' OF FENCING. ACCESS POINT SHALL BE CONSTRUCTED AS BELOW. NOTES: 1. 2. 3. 4. 5. ALL TREE PROTECTION DEVICES ARE TO BE INSTALLED PRIOR TO THE START OF LAND DISTURBANCE AND MAINTAINED UNTIL FINAL LANDSCAPING IS INSTALLED. NO PARKING, STORAGE OR OTHER CONSTRUCTION SITE ACTIVITIES ARE TO OCCUR WITHIN THE TREE PROTECTION AREA. PROVIDE 4" DEEP WOOD CHIP MULCH OVER ANY UNPROTECTED ROOT ZONE. MAKE CLEAN CUTS ON ROOTS EXPOSED BY GRADING AND BACKFILL IMMEDIATELY. INSTALLATION SHALL INVOLVE NO TRENCHING. SIGNS TO BE PLACED AT 50' INTERVALS ALONG 5' FENCE ACCESS POINT 3' FENCE CRZ 5' 24" DBH TREE TREE PROTECTION / L.O.D. FENCING FENCING. SIGNS TO BE A MINIMUM OF 8 21" X 11". SIGNS TO READ: KEEP OUT TREE PROTECTION AREA PROHIBIDO ZONA PROTECTORA PARA LOS ARBOLES 08/01/2015 BY REVISION DATE STD. L-6 EDGE OF PLANTING BED FINAL GRADE 6 TYP. STAGGERED ROWS UP TO MAX. 12" @ CENTER OF BED 1 EXISTING GRADE EQUAL SPACING BETWEEN ALL PLANTS TYPICAL BED MOUNDING TYPICAL PLANTING BED PLAN SPACING VARIES SEE LANDSCAPE PLAN REMOVE ANY BROKEN, DEAD OR DISEASED LIMBS TYP. COLLAR MIN. 2" HT. 6" MIN. 10" DEPTH 4" MIN. 3" LAYER OF APPROVED MULCH "V" TRENCH AROUND ENTIRE PLANTING BED PLANT MIX EDGE OF PLANTING BED TAMP SOIL MIX UNDER EACH PLANT BALL TO MINIMIZE SETTLEMENT CUT ROOTS AS NECESSARY IN CONTAINERIZED PLANTS THAT ARE POT BOUND TYPICAL PLANTING BED DETAIL NOTES: 1. 2. 3. 4. OMIT COLLAR AROUND EACH SHRUB WHEN IRRIGATION SYSTEM IS PRESENT. INSTALL TOP OF PLANT BALL 2"-3" ABOVE ADJACENT GRADE. TAMP PLANTING MIX FIRMLY AS PIT IS FILLED AROUND EACH PLANT BALL. SOAK EACH PLANT BALL AND PIT IMMEDIATELY AFTER INSTALLATION. SHRUB PLANTING BED 08/01/2015 BY REVISION DATE STD. L-7 MINIMUM 8'-0" 2" X 4" WOOD SLATS BOTTOM AS NEAR TO GROUND AS ROOTS ALLOW SAND BAGS NOTES: 1. WHERE ANY EXCEPTIONS RESULT IN A FENCE BEING CLOSER THAN TEN FEET (10'-0") TO A TREE TRUNK; PROTECT THE TRUNK WITH STRAPPED-ON-PLANKING TO A HEIGHT OF EIGHT FEET (8'-0"), OR TO THE LIMITS OF LOWER BRANCHING, IN ADDITION TO THE REQUIRED ORANGE LAMINATE FENCING. 2. ANY ROOTS EXPOSED BY CONSTRUCTION ACTIVITY SHALL BE PRUNED FLUSH WITH THE SOIL. BACKFILL ROOT AREAS WITH GOOD QUALITY TOP SOIL AS SOON AS POSSIBLE. IF EXPOSED ROOT AREAS ARE NOT BACKFILLED WITHIN TWO (2) DAYS, COVER THEM WITH ORGANIC MATERIAL IN A MANNER WHICH REDUCES SOIL TEMPERATURE, AND MINIMIZES WATER LOSS DUE TO EVAPORATION. 3. PRIOR TO EXCAVATION OR GRADE CUTTING WITHIN TREE CRZ, MAKE A CLEAN CUT BETWEEN THE DISTURBED AND UNDISTURBED ROOT ZONES WITH A PRUNING SAW, DITCH WITCH OR SIMILAR EQUIPMENT, TO MINIMIZE DAMAGE TO REMAINING ROOTS. 4. TREES MOST HEAVILY IMPACTED BY CONSTRUCTION ACTIVITIES SHALL BE WATERED DEEPLY ONCE A WEEK DURING PERIODS OF HOT, DRY WEATHER. 5. SAND BAGS OR HAY BALES SHALL BE PLACED ON THE ROOT FLARES AND ANY EXPOSED STRUCTURAL ROOTS. 6. ALL EXPOSED, RIPPED, AND TORN ROOTS GREATER THAN ONE-HALF INCH (1/2") SHALL BE CLEAN CUT. 7. NO LANDSCAPE TOPSOIL DRESSING GREATER THE FOUR INCHES (4") SHALL BE PERMITTED WITHIN THE CRZ OF A TREE. NO SOIL IS PERMITTED ON THE ROOT FLARE OF ANY TREE. 8. PRUNING TO PROVIDE CLEARANCE FOR STRUCTURES, VEHICULAR TRAFFIC AND EQUIPMENT SHALL TAKE PLACE BEFORE CONSTRUCTION BEGINS. TREE PROTECTION WOOD SLATS 08/01/2015 BY REVISION DATE STD. L-9 NOTES: 1. INSTALLATION OF "CU STRUCTURAL SOIL" (OR APPROVED EQUAL) AND BRICK PAVING MUST BE UNDERTAKEN BY AN EXPERIENCED CONTRACTOR. THE CONTRACTOR MUST HAVE EXPERIENCE WORKING WITH THE SPECIFIED MATERIALS AND BE ABLE TO SHOW PROOF OF THIS EXPERIENCE. SAMPLES OF ALL MATERIALS MUST BE SUBMITTED AND BE APPROVED BY THE CITY. THIS WORK WILL BE SUPERVISED BY THE CITY OF ALPHARETTA. 2. IN AREAS NOT ADJACENT TO A TREE PLANTING AREA, THE "CU STRUCTURAL SOIL" (OR APPROVED EQUAL) EXTENDS TO THE BACK OF CURB. 3. LOCATE ALL UTILITIES PRIOR TO DIGGING TREE PITS. DO NOT SPRAY PAINT NEW PAVERS AND CONCRETE INDICATED TO REMAIN. IF AT ALL POSSIBLE WHEN LOCATING UTILITIES, NOTIFY ENGINEER OF ANY CONFLICTS WITH UTILITY LINES. 4. REFERENCE CITY OF ALPHARETTA LANDSCAPE DETAILS L1, L2, L3, L4 AND L8 FOR ADDITIONAL INFORMATION ON TREE PLANTING, ANCHORING AND ROOT BARRIER. INSTALL 18" MECHANICAL ROOT BARRIER ADJACENT TO CURB INSTALL 12" MECHANICAL ROOT BARRIER ADJACENT TO BRICK PAVERS (3 SIDES) HEADER CURB PAVEMENT "CU STRUCTURAL SOIL" (OR APPROVED EQUAL) PLANTING MIX 4' DEPTH COMPACTED SUBGRADE MINIMUM 6' X 6' TREE PLANTING AREA PERFORM DRAINAGE TEST AS DIRECTED BY CITY OF ALPHARETTA ARBORIST 3' MINIMUM ADJACENT TO BRICK PAVERS (3 SIDES) TREE WELL IN BRICK SIDEWALK 02/19/2016 BY REVISION DATE STD. L-10