Stylish Thermostats For Modern Living
Transcription
Stylish Thermostats For Modern Living
Stylish Thermostats For Modern Living Domestic Heating Control Systems Dial Type Thermostats Stylish Dial Type Thermostats These thermostats are used in conjunction with a separate programmer. Headline Information Product Ranges Key Features Mounting Type Flush Mount with Set Back Function - DS-SB 1 Model, suitable for radiator and water Set Back Function Standard dial thermostats are either on or off according to the time clock controlling the system. A set back thermostat is different. It will follow the temperature set on the dial during the timed period and will automatically reduce the set temperature by 4°C when its timed to be off. Surface mounting: DS1/DS1-L and DS1-E/DS1-EL Flush mounting: DS-SB Temperature Range 05-35°C A slide switch on the side of the thermostat allows you to switch between On, Permanent Off or Time Clock. In On mode, the thermostat will maintain the set temperature on the dial, but will ignore the time clock input. Lock Facility DS1-L / DS1-EL Indication Type LED: DS1/DS1-E/DS-SB LCD: DS1-L/DS1-EL Surface Mount with LED Indication - DS1 Series 2 Models, suitable for water & electric heating systems. Set Back Facility DS-SB Dimensions DS1/DS1-L/DS1-E/DS1-EL 92x92x34mm (L,H,D) DS-SB 92x92x17mm (L,H,D) E.U. Back Box DS-SB Dial Type Thermostats Surface Mount with LCD Indication - DS1-L Series 2 Models, suitable for water & electric heating systems. Power and Heating Indication The DS1 series provides power Power and Heating Indication and heating on indication in The DS1 series provides power the form of coloured LEDs. and heating on indication in the of colouredRead-out LEDs. LCDform - Temperature Surface Mount for Easy Installation The DS1 and DS1-L series are surface mounting for easy installation. Modern styling remains in keeping with the rest of the Heatmiser range. Dial Lock Facility The DS1-L series offers a dial lock, allowing you to reduce tampering of the heating system. A simple way of reducing your energy costs. The DS1-L is equipped with an LCD. A turn of the dial will display the set temperature for 5 seconds before reverting back to the actual room temperature Temperature Range Limit read-out. On the DS-SB Public thermostat MAX MAX you can limit the temperature Temperature Range Limit range. Adjustment is only On the DS-SB Public thermostat possible by removing a screw you can the limitDS-SB the temperature making Public features range.for Adjustment is applications. only ideal commercial possible byisremoving a screw The DS-SB shipped ready making DS-SB but Public to work the in On/Off canfeatures be ideal for applications. wired to commercial work in SetBack Mode. The DS-SB is shipped ready to work in On/Off but can be wired to work in SetBack Mode. 02 FEATURES AIR ONLY MODELS AIR & FLOOR MODELS DS1 DS1-L DS-SB DS-SB Public DS1-E DS1-EL Temperature Range 05-35 °C 05-35 °C 05-35 °C 05-35 °C 05-35 °C 05-35 °C Mounting Type Surface Surface Flush Flush Surface Surface Set Back Function N N Y Y N N Digital Display N Y N N N Y Time Clock Override Switch N N Y N N N Dial Lock N Y N Y N Y Built In Air Sensor Y Y Y Y Y Y Remote Air Sensor N N Y Y N N Floor Sensing Mode N N N N Y Y Floor Probe Included N N N N Y Y Built In Air & Floor N N N N Y Y Y Y N N Y Y N N N Y N N Range Limit (Screw required to adjust) Accuracy Dimensions +/- 1.5°C +/- 1.5°C +/- 1.5°C +/- 1.5°C +/- 1.5°C +/- 1.5°C 92x92x34mm 92x92x34mm 92x92x17mm 92x92x17mm 92x92x34mm 92x92x34mm 3A 3A 3A 3A 13A 13A Supply 230VAC 230VAC 230VAC 230VAC 230VAC 230VAC Weight 150g 150g 150g 150g 150g 150g Max Switching Current Flush Mount with Set Back Function DS-SB Public Thermostat with Range Limit DS–SB Public Stylish Thermostats For Modern Living Surface Mount with LCD Indication DS1-L Series Surface Mount with LED Indication DS1 Series 03 Slimline Thermostats Our most popular product line Three ranges are available, available, including including our 230v Slimline Models230v for standard model, Slimline-E systems, Electric 12v Network Floor Heating Models for model those and looking our 12v toNetwork control their Models system ideal for those lookingFloor to control their centrally. centrally and Electric Models for system those with Electric Floor Heating. Headline Information Product Ranges Key Features Mounting Type Flush mounting 230v Models Model Can be used to upgrade existing thermostats and can be used in conjunction with our UH2 and UH3 UH8 wiring centres. Modern Slimline Appearance The slimline thermostat series 12v Network Models Have been designed to work as part of a network system, 12v Network Models and can be used in conjunction Have been designed to work with our UH1 wiring centre and as part of a network system, network products. and can be used in conjunction *See pages 25 for system with our UH1 wiring centre and overview. network products. Electric Floor *See pages 25 Model for system Supplied overview.with a remote floor sensor, the Slimline-E offers the ability to measure room temperature, floor temperature or both. The Slimline-E is rated at 16A making it ideal for electric Electric Floor Model floor heating. Supplied with a remote floor sensor, the Slimline-E offers the ability to measure room temperature, floor temperature Sensor Housing or both. The Slimline-E is rated Part Heatmiser EN030 at 16A making Ref: it ideal for electric This sensor housing is ideal for floor heating. use in en-suites to house the remote sensor probe. Holiday Function Energy Saving Optimum Start Reduces the set temperature Calculates the amount of heat in your home for the duration up time required to ensure Holiday Function Energy Saving Optimum Start of your holiday and returns your home is warm when you Reduces the set temperature Calculates the amount of heat to programmed settings to wake and return home. This in your home for the duration up time required to ensure ensure your home is warm on is automatically optimised of your holiday and returns your home is warm when you your return. throughout the year to save you to programmed settings to wake and return home. This money. ensure your home is warm on is automatically optimised Temperature Temperature Hold your return. Override throughout the yearFacility to save you Allows you to adjust the desired Allows you to hold a set money. temperature in your home without the need to fully duration - ideal for parties. re-program the thermostat. After which, the thermostat This new set temperature will will revert back to the Temperature Override Temperature Hold Facility be maintained until the next programmed setting. Allows you to adjust the desired Allows you to hold a set programmed setting. temperature in your home without the need to fully duration - ideal for parties. re-program the thermostat. Remote Sensor AfterProbe which, the thermostat MISC103 This new set temperature will Part Ref: Heatmiser will revert back to the probe can be used to be maintained until the next This remote sensor programmed setting. programmed setting. probe is supplied with a 3 meter cable which can be extended to 20 meters if required. Temperature Range 05-35°C 41-95°F Lock Facility Yes - All models Indication Type LCD with Blue Back Light Optional Extras Infrared Remote Control Dimensions 98x85x16mm (L,H,D) (13mm Installed) E.U. Back Box Slimline Thermostats a depth of only 13mm after installation. Remote Control All models within our slimline series are compatible with our Infrared remote control. (Part Reference: RM1) 04 FEATURES 230V 12V ELECTRIC FLOOR MODEL Slimline Slimline-N Slimline-HW-N Slimline-E Temperature Range 05-35 °C 41-95 °F 05-35 °C 41-95 °F 05-35 °C 41-95 °F 05-35 °C 05-95 °F Blue Back Lit Screen Y Y Y Y 5/2 Day Programming Mode Y Y Y Y 7 Day Programming Mode Y Y Y Y Number of Heating Levels 4 4 4 4 Optimum Start Y Y Y Y Number of HW Times N N Y N Holiday Function Y Y Y N Keylock Function Y Y Y Y Temperature Hold Function Y Y Y Y Temperature Override Y Y Y Y Temperature Override Limit Y Y Y Y Frost Protection Y Y Y Y Networking Facility N Y Y N °C / °F Option Y Y Y Y Remote Air Sensor Connection Y Y N Y Remote Air Sensor Included N N N N Built In Air Sensor N Y Y Y Floor Sensing Mode N Y N Y Floor Sensor Included N N N Y Max Switching Current 3A 3A 3A 16A +/-1 °C +/-1 °C +/-1 °C +/-1 °C Infrared Remote Control Option Y Y Y Y Adjustable Switching Differential Y Y Y Y 230VAC 12VDC 12VDC 230VAC Accuracy Supply 98x85x13mm(L,H,D) Installed Dimensions 195g Weight 98x85x13mm(L,H,D) 195g 195g 98x85x13mm(L,H,D) 195g Thimble Sensor Remote Sensor Probe Part Ref: Heatmiser Thimble Sensor The Heatmiser Thimble sensor is ideal for discrete temperature monitoring and is compatible with all Heatmiser Thermostats with a remote sensor connection. Part Ref: Heatmiser MISC103 This remote sensor probe can be used to measure air and floor temperature. This probe is supplied with a 3 meter cable which can be extended to 20 meters if required. Stylish Thermostats For Modern Living 05 TouchScreen Thermostats Making your life a little easier The intuitive TouchScreen display makes searching for the user manual a thing of the past. Headline Information Product Ranges Key Features Mounting Type Flush mounting 230v Models 5/2 & 7 Day Programming Frost Protection Can be used to upgrade existing thermostats and can be used in conjunction with our UH2 and UH8 wiring centres. 5/2 Day mode is ideal for those who keep to one schedule Monday - Friday and another for the weekend. 7 Day mode allows you to have a different schedule for each day of the week. Ideal for families with changing schedules. A function designed to protect your home against frost. An adjustable frost temperature level can be programmed, between 7°C - 17°C, ensuring your home is always protected against the elements whilst you are away. 12v Network Models Adjustable Switching Differential Keylock Function Temperature Range 05-35°C 41-95°F Lock Facility Yes - All models Indication Type LCD with Blue Back Light Adjustable Switching Differential 0.5-3°C Dimensions 110x100x17mm (L,H,D) E.U. Back Box Touch Screen Thermostats Have been designed to work as part of a network system, and can be used in conjunction with our UH1 wiring centre and network products. See page 24 and 25 for our system overview. Our TouchScreen Series has an adjustable switching differential from 0.5°C - 3°C. This function allows you to get even tighter control of your heating system. Locking the thermostat keypad is an easy way to save energy. Allowing access to only those that require it. Air / Floor Models Networking Facility Two Zone Models Are supplied with a remote floor sensor and provide the ability to measure room temperature, floor temperature or both. The Touch-E offer 16A switching making them ideal for electric floor heating. Control your heating from anywhere. Our 12v network thermostats offer you the ability to control your heating centrally, with the use of our TouchPad. Take a look at pages 24-25 for more details on our network products. The Touch-Duo is ideal for bedrooms with ensuite. Zone one uses the built in air sensor whilst zone two uses the remote thimble sensor provided. 06 FEATURES 230V 230V MODELS Touch-Duo Touch PRT-TS | PRT-RPTS DT-TS | DT-RPTS ELECTRICFLOOR FLOORMODEL MODEL ELECTRIC 12V 12V NETWORK MODELS PRT/HW-TS Touch-N DT-NTS Touch-HWN PRT-ENTS PRT-NTS PRT/HW-NTS Touch-E PRT-ETS DT-ETS Blue Back Lit Screen Y Y YY Y YY Y Y Y Y Y Y 5/2 Day Programming Mode N Y YY Y NY Y Y Y N Y Y 7 Day Programming Mode N Y YY Y NY Y Y Y N Y Y Number of Heating Levels 1 4 44 4 14 4 4 4 1 4 4 Optimum Start N Y YY Y NY Y Y Y N Y Y Number of HW Times 0 N 0N 4 0N 0 Y4 0 0 N 0 Holiday Function Number of Zones N 1 Y2 Y N- Y Y- Y N - Y Keylock Function Holiday Y Y YY Y YY Y Y Y Y Y Y Temperature Hold Function Keylock Function N Y YY Y NY Y Y Y N Y Y Override Temperature Hold Function Y Y YY Y YY Y Y Y Y Y Y Temperature Override Limit Y Y YY Y YY Y Y Y Y Y Y Frost Protection Temperature Override Limit Y Y YY Y YY Y Y Y Y Y Y Networking Facility Frost Protection N Y NY N YY Y Y Y N Y N °C / °F OptionFacility Networking Y N YN Y YY Y Y Y Y N Y Built Air Sensor °C / °FInOption Y Y YY Y YY Y Y Y Y Y Y Remote AirSensor Sensor Built In Air N|Y Y N | YY N NY N N Y Y Y Y Y Remote Air Sensor Included N|Y N NN N NY N N N N Y N Floor Sensing ModeIncluded Remote Air Sensor N N NN N NN N N Y Y N Y Floor Sensor Included Thimble Air Sensor Included N N NY N NN N N Y Y N Y Max Switching Current Floor Sensing Mode 3A N 3AN 3A 3AY 3A 3A N 3A 16A Y 16A +/-1°C Y Accuracy Floor Sensor Included +/-1°C N N +/-1°C +/-1°C +/-1°C N +/-1°C +/-1°C N +/-1°C Max Switching Current 0.5 - 3°C 3A 3A 0.5 - 3°C 0.5 - 3°C 0.5 -3A 3°C 0.5 - 3°C 0.53A - 3°C 0.5 - 3°C 0.5 - 3°C 16A Accuracy Supply 230VAC+/-1°C +/-1°C 230VAC 230VAC 12VDC +/-1°C 12VDC 12VDC +/-1°C 12VDC 230VAC+/-1°C 230VAC +/-1°C 0.5 - 3°C Adjustable Switching Differential 0.5 - 3°C 0.5 - 3°C 0.5 - 3°C 0.5 - 3°C 0.5 - 3°C Supply 230VAC 230VAC 12VDC 12VDC 230VAC Available In Three Plastic Colour Finishes Thimble Sensor White Part Ref: Heatmiser Sensor HousingThimble Sensor The Heatmiser Thimble sensor is ideal for Part Ref: Heatmiser EN030 discrete temperature monitoring and is This sensor housing is ideal for use in compatible with all Heatmiser Thermostats en-suites to house the remote sensor probe. with a remote sensor connection. Stylish Thermostats For Modern Living Silver Remote Sensor Probe Black Part Ref: Heatmiser Remote Sensor MISC103 Probe This remote sensor probe can be used to measure air and floor Part Ref: Heatmiser MISC103 temperature. This probe is supplied with a 3 meter cable which can be extended to 20 meters if required. temperature. This probe is supplied with a 3 meter cable which can be extended to 20 meters if required. 07 Battery Thermostats & Time Clocks Slimline design to compliment any environment Battery Thermostat Series Headline Our battery thermostats are a viable upgrade route for those with a dial thermostat working on a 2 wire system. Information The design follows our slimline thermostat series with Non-programmable and Programmable models being available. Key Mounting Type Battery Thermostats: Features Surface mounting Time Clocks: Flush mounting Battery Thermostat Temperature Range 05-35°C Lock Facility Battery powered Surface mount Powered from 2 x AAA Batteries – suitable for 2 wire heating systems. Our battery thermostats are surface mounted for easy installation, making them perfect for the Optimum Start Key Lock Function A feature whereby the thermostat calculates the amount of heat up time required, is standard on the Programmable model (PRT-B). Our battery thermostats are equipped with a key lock helping to prevent energy usage by restricting access. Yes - All models Indication Type LCD with Blue Back Light FEATURES Dimensions Battery Thermostats: 86x99x24mm (L,H,D) Slimline Time Clocks: 98x85x16mm (L,H,D) TouchScreen Time Clocks: 92x92x17mm (L,H,D) E.U. Back Box Time Clock Only BATTERY THERMOSTATS DT-B PRT-B 5/2 Day Programming Mode N Y 7 Day Programming Mode N Y Number of Heating Levels 1 4 Optimum Start N Y Holiday Function N Y Keylock Function Y Y Temperature Hold Function N Y Temperature Override Limit Y Y Frost Protection Y Y °C / °F Option Y Y Built In Air Sensor Y Y Accuracy +/-1°C +/-1°C Y Y Supply 2 x AAA 2 x AAA Battery Thermostats & Time Clocks Battery Thermostat Part Ref: Heatmiser PRT-B 08 FEATURES Slimline Time Clock Part Ref: Heatmiser TM1 TIME CLOCKS 230V MODELS TIME CLOCKS 12V NETWORK MODELS TM1 TM4-TS TM1-N Blue Back Lit Screen Keypad TTouchScreen Touch Screen Keypad Keypad/TouchScreen Y Y Y Number of Zones 1 4 1 5/2 Day Programming Mode Y Y Y 7 Day Programming Mode Y Y Y Number of Switching Times 4 4 4 + Boost Facility N Y N N Y N Copy Facility N Y N Countdown Timer Function Y N Y Holiday Function Y Y Y Keylock Function Y Y Y Manual Override Y Y Y Networking Facility N N Y Max Switching Current 3A 3A 3A Changeover Output Option Supply Product Ranges Key Features 230v Models Are designed to work with our UH8 wiring centre and dial thermostat with set back function, providing Number of Zones A single zone can be controlled on the TM1 series and 4 zones can be controlled on the TM4 series. Y N N 230VAC 230VAC 12VDC + Boost Facility A mode select button providing an easy method of switching between permanent on, permanent This programmable function allows you to extend the program time, in 30 minute increments - ideal for unscheduled operation of the system. mode) TM4 only. 12v Network Models Have been designed to work as part of a network system, and can be used in conjunction with our UH1 wiring centre and network products. Number of Switching Times provided on all time clock models, allowing heating system. Stylish Thermostats For Modern Living Countdown Timer From Towel Rails to Lighting A simple yet useful function that enables the output for the duration of the programmed countdown time. All time clock models can be used to control anything - not just your heating system. In fact, those using our networking system can control each time clock independently from the TouchPad or over the internet, so it makes sense to use one of our time clocks wherever you want complete control. 09 Wireless Thermostats Wireless design for easy installation alternative, and are the ideal choice for extensions or when you are looking to relocate your thermostat. Headline Information Key Features Mounting Type Relocate Rechargeable Battery Fail Safe TouchScreen: Desk & Wall mounting Slimline: Wall mounting (TouchScreen models only) Our Wireless TouchScreen series incorporate a rechargeable battery, saving money on replacement batteries. A USB recharge cable is provided, and an optional plug-in charger is available. A loss of wireless connection could leave your home vulnerable to frost damage. The fail safe function enables the heating for 20% of the time, ensuring the temperature in your home does not drop to dangerous levels. Yes - All models Many thermostats are sited incorrectly, causing your boiler to come on more than necessary. A wireless thermostat allows you to move your thermostat to a more suitable position, without the need to run additional cables. What’s more, our TouchScreen models have a desk stand, enabling you to move the thermostat around the house with you. Indication Type Key Lock Function Compatible Electric FloorReceivers Model Easily Change Batteries LCD with Blue Back Light A simple way to reduce tampering of the system settings, and standard across our wireless thermostat series. Our Wireless thermostats are compatible withof our models are capable 2switching channel RF-Switch and up to 16A and 8 zone UH8-RF wireless receivers. Temperature Range 05-35°C 41-95°F Lock Facility Dimensions TouchScreen Thermostats: 110x100x21mm (L,H,D) Battery Thermostats: 86x99x24mm (L,H,D) TouchScreen Wireless Thermostat Series Wireless Thermostats Rechargable Battery (via USB) (Slimline models only) Slimline Wireless Thermostat Series 10 FEATURES AIR ONLY MODELS FEATURES ELECTRIC FLOOR MODELS Slimline-RF SLIMLINE WIRELESS SERIES COMPATIBLE RECEIVERS Compatible Receivers PRT-W DT-W RF Switch RC1-W Compatible UH8-RF Y TOUCHSCREEN WIRELESS SERIES PRTHW-W DT-EW PRT-EW Y N N Y N N N Y Operating Type N N N RC1-WTS Compatible N Temperature Range N N N RC2-WTS Compatible N Heating Only Mode (Selectable by User) Y Y Y UH1-W Compatible N Heating & Hot Water Mode (Selectable by User) 05-35 °C 05-35 °C 05-35 °C 05-35 °C Non Programmable Mode Temperature Range 41-95 °F 41-95 °F 41-95 °F 41-95 °F 5/2 Day Programming Mode Y Y N N 5/2 Day Programming Mode 7 Day Programming Mode Y Y N N 7 Day Programming Mode Number of Heating Levels 4 4 1 1 Number of Heating Levels Optimum Start Y Y N N Optimum Start Number of HW Times RC2-W Compatible ELECTRIC FLOOR MODELS Touch-RF AIR ONLY MODELS Y N N N 05-35 °C 41-95 °F Y Y 4 Y DT-WTS DT-UWTS Y N Y PRT-WTS PRT-UWTS N N N N N Button N Y 05-35 °C - 41-95 °F N N Y Y N Y 05-35 °C Y 41-95 °F Y N Y N 4 1 Y N 4 N N Y N N N N Y 05-35 °C 41-95 °F Y Y 4 Y PRTHW-WTS PRTHW-UWTS Y NY N Touchscreen Y 05-35 °C - 41-95 °F N Y N Y 05-35 °C Y 41-95 °F Y Y Y Y 4 4 Y Y 4 DT-EWTS PRT-EWTS N N N N N N N N N N Y Y Y N N 05-35 °C 05-35 °C 41-95 °F 41-95 °F N Y N Y 1 4 N Y 0 Holiday Function N Keylock Function 0 4 0 0 Y 4 0 0 Y Y N Y Y 0 Y N 0 Holiday Function Y Y Y N Y Number of HW Times Keylock Function Y Hold Temperature Y Y Y Y Y Y Y Y Y Y Y Temperature Hold N Override Y Temperature Y N Y Y N Y Y Y N Y Temperature Override Y Frost Protection Y Y Y Y Y Y Y Y Y Y Y Frost Protection C/F FunctionY Y Y Y Y Y Y Y Y Y Y Y °C / °F Option Built in Air Sensor Y Y Y Y Y Y Y Y Y Y Y Y Built in Air Sensor Remote Air Y Sensor Connection Y Y Y Y Y Y Y N Y Y Y N Y Y 1 °C N N 1 °C N N N N N N Y N N N Y Y Y N Y N N N N Y N Y Y N 868MhZ N N N +/-1°C +/-1°C +/-1°C Y Y Y Y Remote Air Sensor ConnectionAccuracy N Diff N erential N Remote Air Sensor Included Adjustable Switching Floor Sensing Mode Wireless FailNSafe Function N Floor Sensor Included RF Frequency N N N Operational Radio Range (Open Space) +/-1°C +/-1°C +/-1°C Power Y Y Y Battery Lifetime Y Y Y USB Power Lead Included 868MHz 868MHz 868MHz Mounting Type Up to Up to Up to Dimensions 100M 100M 100M Accuracy Wireless Fail Safe Function RF Frequency Operational Radio Range (Open Space) N +/-1°C Y Y 868MHz Up to 100M 868MhZ N Up to 100M +/-1°C +/-1°C 2 X AAA Y Y 1 Year Y Y N 868MHz 433MHz | 868MHz Wall Up to Up to 85mm(L) x 98mm (H) x 24mm 100M 100M N Up to 100M +/-1°C Rechargeable Battery Y 1 Year Y Y Y 433MHz | 868MHz 433MHz | 868MHz Wall/Desk Up to Up to 110mm(L) 100mm (H) x 20mm (D) 100M 100M Y Y 433MHz Up to 100M Power 2 x AAA 2 x AAA 2 x AAA 2 x AAA 2 x AAA Battery Lifetime Typically Typically Typically Typically Typically Typically Typically Typically Typically 1 Year 1 Year 1 Year 1 Year 1 Year 6-8 Months 6-8 Months 6-8 Months 6-8 Months USB Power Lead Included Mounting Type Dimensions Rechargable Battery (Mini USB Connection) N N N N N Y Y Y Y Wall Wall Wall Wall Wall Wall/Desk Stand Wall/Desk Stand Wall/Desk Stand Wall/Desk Stand 85mm(L) x 98mm(H) x 24mm(D) Stylish Thermostats For Modern Living 110mm(L) x 100mm(H) x 20mm(D) 11 Wireless Receivers H HW-UWTS A H PRT-W Wireless Thermostat Inc HW) A H PRT-W (Programmable Wireless Thermostat) PRTHW-UWTS (Programmable Wireless Thermostat) ply Headline Headline Information Information ADDRESS N L nals) FUSE 1 ACTUATORS W alve ess Thermostat) Slimline Thermostat Wireless Receivers FUSE 4 12V FUSE CONTROL FUSE 3 CONTROLS Mounting Type PRT-W PRTHW-UWTS H A H Wireless Antenna A PRT-W UH1-W RF Switch / Boost Slimline & TouchScreen Receivers: Flush Mounting Surface Wiring Mounting UH1-W Centre: Wall Mount (Programmable Wireless Thermostat Inc HW) (Programmable Wireless Thermostat) (Programmable Wireless Thermostat) Heating UH8-RF ostat N L ADDRESS L DHW SL ZONE1 N FUSE 4 12V FUSE CONTROL N ntrol To Boiler Enable N L N L FUSE 2 ZONE 8 PUMP VALVE N L L ZONE 7 N L ZONE 8 108x90x24mm (L,H,D) Receivers: Slimline & TouchScreen Radiator Zone Valve UH8-RF: 86x86x16mm (L,H,D) 384x148x60mm (L,H,D) Wiring Centre Receiver: 290x200x70mm (L,H,D) PUMP VALVE N L L Compatability Compatability UFH Manifold (Using 230v Actuators) Wireless Slimline Thermostat Wireless Slimline Thermostat Part Ref: Slimline-RF Wireless Receivers (Using 230v Actuators) Part Ref: Heatmiser RC1-W The Heatmiser RF Switch is our surface mount 2 channel RF Receiver compatible with the Slimline RF and Touch RF Thermostats. capable of controlling two heating zones, using our DT-W/PRT-W or one heating and one hot water zone, using our PRTHW-W. A single Slimline RF / Touch RF in Heating Only mode or a single Slimline RF / Touch RF in Heating/Hot Water mode can be paired to the RF Switch. Part Ref: Heatmiser RC2-W The RF Switch can be paired to multiple UH8-RF, providing a wireless link for the boiler signal. Slimline Wireless Repeater Part Ref: WR1 The WR1 is our 230v powered wireless repeater, designed to extend the communication 8 Zone Wiring Centre distance between the thermostat and receiver. Part Ref: Heatmiser UH8-RF Wireless Slimline Thermostats DT-W, PRT-W, PRT-EW, PRTHW-W Wireless TouchScreen Thermostats DT-UWTS, PRT-UWTS, PRTHW-WUTS UFH Manifold Part Ref: Heatmiser PRT-W Heatmiser RF Switch Wireless Receiver for Twin Heating Zones In addition to the two changeover contacts for the heating and hot water circuits, the RF Switch provides a volt free switch for the boiler. with our DT-EW or PRT-EW thermostat and is supplied with a 3 meter Wireless Antenna To Boiler FUSE 2 Enable ZONE 6 N e Thermostat miser PRT-W N L ZONE 7 STAT 6 VALVE AND PUMP ENABLE Radiator Zone Valve Centre H1-W ZONE 6 Dimensions RF Switch / Boost Dimensions UH1-W oducts ZONE 5 N L Radiator Zone Valve ermostat) L ZONE 4 STAT 6 VALVE AND PUMP ENABLE To Boiler Enable W N ZONE 3 N L LED Radiator Zone Valve To Boiler Enable ZONE 5 ZONE 2 Indication Type LED Indication Type L L A BOILER ENABLE (VOLT FREE) Fused Spur) N H PRT-W (Programmable Wireless Thermostat) (Programmable Wireless Thermostat) Our wireless receivers are designed Heating to work with our wireless thermostats and are ideally suited for water underfloor heating and conventional heating systems. as well as conventional radiator systems. adiators ZONE 4 A PRT-W (Programmable Wireless Thermostat Inc HW) Heatmiser Boost Wireless TouchScreen Thermostat Part Ref: Heatmiser PRT-UWTS UH1-W, RC1-W, RC2-W E.U. Back Box The Heatmiser Boost is our surface mount 230v powered wireless repeater for the RF and Neo systems designed to extend the TouchScreen Thermostat Wirelesscommunication Receivers distance between the thermostat and receiver. Wireless Receiver for Twin Heating Zones Part Ref: Heatmiser RC1-WTS Wireless TouchScreen Thermostat Wireless TouchScreen Thermostat Part Ref: Heatmiser PRT-UWTS Part Ref: Touch-RF Wireless Receivers TouchScreen wireless thermostats. Two heating zones can be controlled using our DT-WTS/PRT-WTS or alternatively, one heating and one hot water zone can be controlled from this receiver using our PRTHW-WTS. 12 FEATURES Mounting Type Compatible with RF-Switch UH8-RF Surface Surface Slimline RF / Touch RF Slimline RF / Touch RF Number of Channel 2 8 Fail Safe Y Y Power 230V AC 230V AC Rating 3A 3A Optional Extendable Aerial N Y 868MHz 868Mhz Operating Frequency Range(Open Space) 100M 100M Pump Output N Y Zone, HW & Pump Output Test Mode N Y Boiler Enable Y Y HW Cylinder Thermostat Connection N Y Per Zone UFH / Radiator Selection N Y Wireless Wiring Centre Wireless 230v 8 Zone Wiring Centre Part Ref: Heatmiser UH8-RF The UH8-RF is designed to be used in conjunction with our Slimline RF and Touch RF Wireless Thermostats. The UH8-RF provides central switching and is therefore ideally situated next to the underfloor heating manifold. Eight zones can be controlled as well as providing an output for a hot water cylinder. On demand from any zone, a 230v output is provided to switch the relevant zone actuators, underfloor heating pump and valve. A volt free connection is supplied for the boiler making it compatible with almost all types of boilers. The RF Switch can also be paired to multiple UH8-RF providing a wireless link for the boiler enable signal. Up to 6 actuators can be connected to each zone. An external aerial is available for use when the UH8-RF is being mounted in a metal cupboard or when the wireless signal is restricted. A software option in the thermostat allows you to configure which zones are underfloor heating and which zones are radiators. Radiator zones will not enable the underfloor heating pump and underfloor heating valve when there is a call for heat. Stylish Thermostats For Modern Living 13 WiFi Smart Thermostat SmartStat is our all-new WiFi Connected Thermostat with full colour LCD. Now is the time to take control of your multi zone heating and hot water system from anywhere. What’s more, our Geo Location feature ensures you never heat an empty home. Headline Information Key Features Mounting Type Flush mounting Control from your SmartPhone Temperature Range 05-35°C 41-95°F Indication Type 2.8” Full Colour LCD Dimensions 95x95x45mm (15mm installed) E.U. Back Box SmartStat has built in WiFi so connects directly to your Home Router. As SmartStat connects to your SmartPhone via our cloud server setup is a dream and will take minutes – no technical setup here. SmartStat is compatible with iPhone & iPad and with Android SmartPhones & Tablets. Heat or Timer Option The SmartStat can be setup to work in either Heat or Timer mode, so is perfect for controlling heating zones or timer zones such as towel rails and hot water. Auto Dimming The SmartStat Display can be programmed to automatically dim in low light – making SmartStat perfect for bedrooms. SmartStat Frost Protection Geo Location Don’t worry we have your home covered. The in built frost protection feature will protect your home against the elements. Geo Location uses the mobile phone masts, nearby WiFi and your GPS to calculate your position. When you setup Geo Location on the SmartStat App, you set a leaving and returning trigger. When you pass these triggers, SmartStat will adjust the temperature in your home automatically. Thermostat and Programmer in One Gone are the days of having a separate programmer and thermostat. SmartStat is both in one so you no longer have to fiddle with the awkwardly positioned thermostat. Comfort Programming Now is the time to re-think how you heat your home. SmartStat lets you have different temperatures at different times of the day, not only an energy saving feature but one that creates for a more comfortable living environment too. The Self Learning Optimum Start feature will automatically calculate when your heating should be on, so it’s one less thing for you to worry about. Multi-Zone Up to 32 SmartStats can be controlled within one location without the need for any network hub. Global features such as Temperature Hold, Key Lock and Home/Away are all available on the SmartStat App. Multi User Multiple users can login to the SmartStat App and take control of the heating & hotwater from anywere. In addition, Geo Location can be configured on each persons device meaning the heating is turned off when the last person has left home and back on when the first person returns. 14 FEATURES SMARTSTAT Available In Two Stunning Colours 05-35 °C 41-95 °F Temperature Range Blue Back Lit Screen Y Non-Programmable Mode Y 5/2 Day Programming Mode Y 7 Day Programming Mode Y 24 Hour Programming Mode Y Number of Heating Levels 4 Optimum Start Y Number of HW Times 0 Holiday Function Y Temperature Hold Function Y Temperature Override Y Temperature Override Limit Frost Y Protection Y App Control Y °C / °F Option Y Remote Air Sensor Connection Y Built In Air Sensor Y Floor Sensing Mode Y Floor Sensor Included N Max Switching Current 3A Sapphire Black +/- 1°C Accuracy Adjustable Switching Differential +/- 1-3°C Supply 230VAC Output Volt Free Contact 95x95x15mm (L,H,D) Installed Dimensions 128g Weight Glacier White Thimble Sensor Remote Sensor Probe Part Ref: Heatmiser Thimble Sensor The Heatmiser Thimble sensor is ideal for discrete temperature monitoring and is compatible with all Heatmiser Thermostats with a remote sensor connection. Part Ref: Heatmiser MISC103 This remote sensor probe can be used to measure air and floor temperature. This probe is supplied with a 3 meter cable which can be extended to 20 meters if required. Stylish Thermostats For Modern Living 15 Modern touch touch technology technology Modern TheneoStats neoStatshave havebeen beendesigned designedto tobe besimple simpleto touse useand andmake makeprogramming programmingsimple simplewith withthe thenew newintuitive intuitivemenu menunavigation. navigation. The TheneoStats neoStatscan canbe becontrolled controlledfrom fromanywhere anywherethanks thanksto tothe theplug plugand andplay playneoHub, neoHub,and andare areavailable availableininGlacier GlacierWhite Whiteand andSapphire SapphireBlack. Black. The Headline Headline Information Information Key Key Features Features MountingType Type Mounting Flushmounting mounting Flush ModernSlimline SlimlineAppearance Appearance Modern TheneoStat neoStatthermostat thermostatseries series The flushmounting, mounting,resulting resultinginin isisflush depthof ofonly only15mm 15mmafter after aadepth installation. installation. EnergySaving SavingOptimum OptimumStart Start Energy Calculatesthe theamount amountof ofheat heat Calculates uptime timerequired requiredto toensure ensure up yourhome homeisiswarm warmwhen whenyou you your wakeand andreturn returnhome. home. This This wake automaticallyoptimised optimised isisautomatically throughoutthe theyear yearto tosave saveyou you throughout money. money. TemperatureHold HoldFacility Facility Temperature Allowsyou youto tohold holdaaset set Allows temperaturefor foraaspecific specific temperature duration- -ideal idealfor forparties. parties. duration Afterwhich, which,the thethermostat thermostat After willrevert revertback backto tothe the will programmedsetting. setting. programmed Heator orTimer TimerOption Option Heat TheneoStat neoStatcan canbe besetup setup The towork workinineither eitherHeat Heator or to Timermode, mode,so soisisperfect perfectfor for Timer controllingheating heatingzones zonesor or controlling timerzones zonessuch suchas astowel towelrails rails timer andhot hotwater. water.The Thequick quicksetup setup and menuenables enablesthe theinstaller installeror or menu homeowner ownerto toselect selectbetween between home thetwo twomodes, modes,and andby by the incorporatingthe thetwo twomodes modes incorporating intoone oneproduct productmeans meansone one into lessSKU SKUfor forstockists. stockists. less WirelessNetworking Networking Wireless Althoughthe theheating heatingsignal signalisis Although hardwired, wired,the thecommunication communication hard dataisissent sentwirelessly wirelesslyvia viaour our data meshnetwork networkto tothe theneoHub. neoHub. mesh OurNeo Neonetwork networkhas hasbeen been Our designedto tooffer offeraareliable reliableand and designed scaleablenetwork networksystem, system,offering offering scaleable controlof ofup upto to32 32neoStats neoStatson on control onenetwork. network.The TheneoHub neoHubwill will one automaticallyroute routethe thedata data automatically aroundyour yourhome homeensuring ensuringrange range around neveran anissue. issue. isisnever Perfectfor forNew NewBuild Build & Perfect &Retrofit Retrofit As Asthe theneoStat neoStatisismains mains powered, powered,ititisisperfect perfectfor fornew new homes homesand andfor forretrofitting retrofittingto to existing existingproperties propertiesas asthere there are areno norequirements requirementsfor forCAT5 CAT5 Data cable and you don’t Data cable and you don’t need needto toworry worryabout aboutreplacing replacing batteries either! batteries either! EasyNavigation Navigation Easy TheneoStat neoStatseries seriesoffers offersan an The easyto tonavigate navigateprogramming programming easy system,providing providingall allof ofthe the system, optionsacross acrossthe thebottom bottomof of options theblue blueback backlitlitdisplay. display. the SoftTouch TouchOperation Operation Soft Moderntouch touchsensitive sensitive Modern keysprovide provideaaclean cleansmooth smooth keys interface,adding addingfurther furtherto tothe the interface, premiumfeel feelof ofthe theneoStat neoStat premium series. series. Remote Sensing Neo can be used with remote air and floor sensors to cater for applications where remote temperature monitoring is required. TemperatureRange Range Temperature 05-35°C 05-35°C 41-95°F 41-95°F LockFacility Facility Lock Yes- -All Allmodels models Yes IndicationType Type Indication LCDwith withBlue BlueBack BackLight Light LCD Dimensions Dimensions 85x85x40mm(L,H,D) (L,H,D) 85x85x40mm (15mmInstalled) Installed) (15mm E.U.Back BackBox Box E.U. Wireless Thermostats neoStat neoStat 16 16 FEATURES STANDARD MODELS Temperature Range ELECTRIC FLOOR MODEL neoStat neoStat-hw neoStat-e 05-35 °C 41-95 °F N/A 05-35 °C 41-95 °F Blue Back Lit Screen Y Y Y Non-Programmable Mode Y N Y 5/2 Day Programming Mode Y Y Y 7 Day Programming Mode Y Y Y 24 Hour Programming Mode Y Y Y Number of Heating Levels 4 N/A 4 Optimum Start Y N Y Number of HW Times 0 4 0 Holiday Function Y Y Y Temperature Hold Function Y N Y Temperature Override Y N Y Temperature Override Limit Frost Y N Y Protection Y N Y Networking Facility Y Y Y °C / °F Option Y N Y Remote Air Sensor Connection Y N Y Built In Air Sensor Y N Y Floor Sensing Mode Y N Y Floor Sensor Included N N Y Max Switching Current Accuracy 3A 3A 16A +/- 1°C N/A +/- 1°C Adjustable Switching Differential +/- 1-3°C N/A +/- 1-3°C Supply 230VAC 230VAC 230VAC Output Volt Free Contact Changeover 85x85x15mm (L,H,D) Installed Dimensions 128g Weight 128g Available In Three Stunning Colours Sapphire Black Glacier White 230VAC 85x85x15mm (L,H,D) 128g Platinum Silver Thimble Sensor Remote Sensor Probe Part Ref: Heatmiser Thimble Sensor The Heatmiser Thimble sensor is ideal for discrete temperature monitoring and is compatible with all Heatmiser Thermostats with a remote sensor connection. Part Ref: Heatmiser MISC103 This remote sensor probe can be used to measure air and floor temperature. This probe is supplied with a 3 meter cable which can be extended to 20 meters if required. Stylish Thermostats For Modern Living 17 Multi-Zone Control Modern touch technology The The neoStat neoStat has has been been designed designed to to replace replace aa standard standard mains mains powered powered thermostat thermostat and and provides provides the the ability ability to to create create aa network network system, system, with with local local and and remote remote access. access. With With neo neo you you can can control control your your heating heating from from anywhere anywhere using using your your smartphone smartphone or or tablet. tablet. Headline Information Mounting Mounting Type Type Flush Flush mounting mounting Connectivity Connectivity Standard Standard Wireless Wireless Mesh Mesh Network Network Technology Technology Lock Lock Facility Facility Yes Yes -- All All models models SmartPhone SmartPhone App App iPhone iPhone // iPad iPad Android Android Tablet Tablet & & Phone Phone Kindle Kindle Devices Devices Windows Windows Phone Phone Supported Supported Dimensions Dimensions 85x85x40mm 85x85x40mm (L,H,D) (L,H,D) (15mm (15mm Installed) Installed) Key Features Features Local Local Control Control (In (In case case of of loss loss of of Broadband Broadband Connection) Connection) Should Should the the internet internet connection connection fail, fail, the the heating heating system system can can still still be be operated operated within within the the home home by by using using the the thermostat thermostat keypad. keypad. As As soon soon as as the the internet internet connection connection is is restored, restored, your your neoHub neoHub will will automatically automatically logon logon to to the the Cloud Cloud Server Server re-enabling re-enabling app app control. control. Multi-Zone Multi-Zone The The Heatmiser Heatmiser Neo Neo Network Network system system has has been been built built from from the the ground ground up up with with multi-zone multi-zone homes homes in in mind. mind. The The neoHub neoHub coordinates coordinates the the data data between between each each neoStat neoStat thermostat thermostat on on the the network. network. API API API -- Third Third Party Party Integration Integration Our Our published published API API (JSON) (JSON) makes makes it it easy easy for for third third party party integration integration companies companies to to integrate integrate our our Neo Neo Network Network System System with with leading leading home home automation automation brands brands products products from from companies companies such such as as Control4 Control4 and and Crestron. Crestron. Multi-Locations Multi-Locations During During the the installation installation of of the the app, app, you you are are prompted prompted to to create create an an account account on on the the Heatmiser Heatmiser Cloud Cloud Server Server after after which which multiple multiple locations locations can can be be created. created. Logging Logging into into to to your your account account from from another another device device will present all ofallyour Locations for will present of your Locations quick andand easyeasy access. for quick access. Plug Plug and and Play Play The neoHub connects connects directly directly to to aaspare spareport porton onyour yourrouter, router,obtaining obtainingananIPIP The neoHub Address and joining joining itself itself to to your your home homenetwork. network. ItIthas hasbeen beendesigned designedtotobe be Address and simple simple to to install install and and setup, setup, and and is is compatible compatible with with broadband broadband connections connections with with Dynamic Dynamic IP IP Addresses. Addresses. The The neoHub neoHub connects connects to to our our Cloud Cloud Server Server eliminating eliminating any any complex complex setup setup requirements requirements including including port port forwarding. forwarding. E.U. E.U. Back Back Box Box Multi-Zone Control Multi-Zone Control 18 18 Multi User Control A new feature of the neoApp is the ability to have multiple users, providing an easy way of giving friends and family access to your heating system. The Share and Geo Location features mean that you never need to heat an empty home – or return to a cold home any longer. Share Modes Geo Location & Share Guest Share A Guest Share has limited access to the Neo System providing the ability to Hold a Temperature, Lock a Thermostat, Place the Heating into Standby mode and make temporary temperature changes. They cannot reprogram heating levels, remove zones or setup Geo Location. Energy Saving when you Leave Geo Location works on a User Level, so each user can setup their own preferred Leave and Return Trigger Distances, Temperatures and Applicable Zones. When the last person has left home, the Leave temperature will be sent to the zones configured. Rest assured Neo won’t turn the heating off if somebody is still at home – it only works when the last person has left. In addition, Guest user access will be revoked on the date set in the neoApp - so is perfect for holiday rental applications. A Warm Welcome Home When the first person heads home, the Return temperatures will be sent to the configured zones ensuring that your home is warm for your return. Adjustment Notifications Whenever Neo makes an adjustment to your heating system a notification will be presented in your phones notification centre so you’re always kept informed of the status of your Neo System. Admin Share Admin users have full access to the system including the Geo Location feature. Stylish Thermostats For Modern Living 19 Base Level Heating & Radiator System Our base level water underfloor heating system uses our UH8, 8 Zone wiring centre. With the flush mount set back thermostats and 4 zone touchscreen time clock, this creates a simple, yet cost effective solution. Headline Information Key Features Set Back Function Connections for 8 x Zone outputs (suitable for 230v actuators) 230v Output for UFH Pump & Valve Control Volt Free Boiler Enable Component Dimensions Time Clock 110x100x17mm (L,H,D) Set Back Thermostat 86 x 86 x 19mm (L,H,D) Wiring Centre 384 x 148 x 60mm (L,H,D) Our base level heating system offers simple but effective control of up to eight zones*. The UH8 wiring centre is the hub of this system and is designed to work with our four channel 230v Time Clock (TM4) and 230v Set Back Thermostat (DS-SB). On board the UH8 are two heating time channels. Each zone allows you to specify which time channel it should follow. Two additional time channel connections are provided for hot water control or other auxiliary devices. * Additional zones can be controlled with the use of a second UH8. The set back function is a simple way of reducing temperature when the heating is timed to be according to the time clock controlling the system. temperature set on the dial during the timed period and will automatically reduce the set temperature DIN Rail Mounting The UH8 wiring centre can be DIN Rail Mounted for simple, easy installation. Providing Wiring centre, controlling up to 8 zones 4 Zone Master Time Clock 230v Set Back Thermostat in each room Neon Indication Radiator Zone Control Neon indicators are provided on the UH8 allowing you to see the power, valve, boiler and zone status without the need to remove the cover. A simple slide switch makes zone eight suitable for controlling a radiator zone. When used for controlling radiators, zone 8 does not enable the Simple Connectivity 230v Models Are designed to work with our UH8 wiring centre and dial thermostat with set back function, Product List 8 Zone Wiring Centre Part Ref: Heatmiser UH8 (See page 31) 4 Zone Time Clock Part Ref: Heatmiser TM4 (See page 09) Set Back Thermostat Part Ref: Heatmiser DS-SB (See page 03) The UH8 allows the connection of up to eight 230v room thermostats. On demand from any zone, a 230v output is provided to switch the pump and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers. Base Level Water Underfloor Heating & Radiator System 20 neoStat (Timer) neoStat 230VAC CYLINDER NOT NOT USED USED L N A1 A2 neoStat (Connected to Zone 2) (Connected to Zone 1) HOT WATER DS-SB Thermostat DS-SB Thermostat VALVE (Connected to Channel 2) (Connected to Channel 1) TM4THERMOSTAT Time Clock (4 Independant NC Channels) UH8 MOTOR C NO UFH POWER SUPPLY 3A 230V L N UFH UFH L HEATING L A1 N N SL DS-SB STAT DS-SB STAT DS-SB STAT L L L N SL R T+ R T- L N 2 3 4 1 TIME CLOCK SL L N 1 3 4SL TIME CLOCK 1 R T+ R T- L N L 1N 2 L N N SL L N ZONE1 2 1 ZONE1 N SL ZONE 2 1 2 ZONE 2 L R T+ R T- ZONE 3 2 1 ZONE 3 1 ZONE 4 L N SL L N 1 ZONE 4 2 L L N SL 2 DS-SB STAT R T+ R T- SL L N 1 SL 2 N SL L N SL L N 1 SL 2 SL DS-SB STAT L N SL L N 1 SL 2 A2 L N CH1 CH2 CH3 CH4 A1 N A2 L N TM4-TS TIMER L UFH BOILER ENABLE ZONE 5 2 1 ZONE 5 SL L N 1 SL 2 L N ZONE 6 2 1 ZONE 6 L N SL L N1 SL 2 SL 2 1 ZONE 7 2 1 ZONE 7 FOUR CORE AND EARTH 1.5 CABLE NO E L N E N 1 UH3 ZONE 1 L 2 E HEAT ENABLE LS E LR LS AND LR IS VOLT FREE 1 ZONE 2 2 MAINS UFH SUPPLY PUMP L L E L SL MAINS SUPPLY R1 R2 N GR OR BOILER L N N L N ZONE 3 1 2 L L L L E N N L N N ZONE 2 L L N L UFH PUMP 2 L SL L N N ZONEL4 ZONE 3 L L N L N N SL L L N L N N ZONE 5 N L E N 1 ZONE ZONE54 L L ZONE 6 N L SL ZONE 6 N ZONE 7 L E N ZONE 7 ZONE 5 L N 1 LN L SL L L N ZONE 1 ZONE 2 ZONE 3 ZONE 4 ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V 1 N 2 L SL N UFH SL ZONE 8 E N 1 A1 2 SL RAD ZONE 8 ZONE 7 N L L N N L L N N N neoStat (Connected to Zone 8) DS-SB Thermostat (Connected to Channel 1)Zone Valve Radiator Boiler Radiator Zone Valve To Enable N LN ACTUATOR 230V E ZONEZONE 8 6 N ZONE 8 L ZONE 7 2 L N LN ZONE 6 2 A2 L L ZONE 5 2 1 ZONEZONE 3 3ZONE 4 ZONE 2 ZONE 2 L E N YES YES ZONE 4 1 N N LN UFH VALVE Boiler N ZONE 1 N L N N (Via Heating/Hot ENABLE Water System Fused Spur) Boiler E ZONE 1 ZONE 1 230V AC Supply (Via Heating/Hot Water System Fused Spur) 230V AC Supply BOILER (Heating Enable Terminals) L SL UFH PUMP UFH VALVE BOILER UFH PUMP N E NO ZONE 8 TYPE L 2 ZONE 8 ZONE 8 UH3 FUSE Heating or Manifold Valve Heating or Manifold ValveMAINS TIME CLOCK 5A FUSE R T+ R T- 2 FUSE MAINS SUPPLY N SL SL RADIATOR VALVE Zone 8 Isolation Switch If set to YES, Zone 8 enables the Boiler Pump and Valve. If set to NO Zone 8 is isolated. Zone 8 Isolation Switch VALVE WITH ENDSWITCH PLEASE ADD LINK TO GR AND OR IF VALVE NOT FITTED If set to YES, Zone 8 enables the Boiler Pump and Valve. If set to NO Zone 8 is isolated. (Heating Enable Terminals) PL SL PL SL PL PERMANENT LIVE UFM UNDER FLOOR SL MANIFOLD SWITCH LIVE PL PERMANENT LIVE LIVE SL SWITCH LIVE TIMER LIVE SWITCH LIVE This equipment should be installed by an appropiately qualified/registered electrician. Fully read the instructions for proper wiring before applying power. The warranty does not cover damage from improper wiring or installation. UFH Manifold (Using 230v Actuators) UFH Manifold NEUTRAL (Using 230v Actuators) EARTH Standard Products Standard Products END SWITCH AND BOILER ENABLE 8 Zone Wiring Centre Part Ref: Heatmiser UH3 8 Zone Wiring Centre 8 Zone WiringUH3 Centre Part Ref: Heatmiser Part Ref: Heatmiser UH8 neoStat (Heat Mode) Part Ref: neoStat Stylish Thermostats For Modern Living neoStat (Timer Mode) Part Ref: neoStat 4 Zone Time Clock Part Ref: Heatmiser TM4-TS neoHub Part Ref: neoHub Back Thermostat Set BackSet Thermostat Ref: Heatmiser Part Ref: Part Heatmiser DS-SB DS-SB 21 To Boiler Enable Wireless Heating & Radiator System Designed to be easy to install and operate Our wireless system is compatible with our wireless thermostats. Communication between the thermostat and wiring centre is achieved by reliable RF (radio frequency) communication, using the 868Mhz frequency band. This means the installer only needs to wire the boiler, pump and actuator connections, which are normally all local to the wiring centre. Headline Information Key Features Features Providing Simple Process SimplePairing Pairing Process Up within thethe Up to to 99 99UH8-RF’s UH8-RF'scan canbebeused used within same ofof upup to to a a same building, building,allowing allowingcontrol control possible has anan possible792 792zones. zones.Each EachUH8-RF UH8-RF has address onon the PCB. addresssetting settingclearly clearlymarked marked the PCB. This relevant zone This address, address,along alongwith withthe the relevant zone number in the thermostat numberisiscongured configured in the thermostat and setup and and that’s that’sitit––aasimple simpletotoinstall, install, setup and operate operatesystem. system. Connectivity Connectivity Hot Water Control The UH8-RF also takes care of the hot water. Hot Water Control A volt free changeover output is provided The UH8-RF also takes care of the hot water. for the cylinder stat/hot water valve. A volt free changeover output is provided The Slimline-RF & Touch-RF provide time and for the cylinder stat/hot water valve. temperature control of the heating and The Slimline-RF & Touch-RF offer time and time control of the hot water. temperature control of the heating and time control of the hot water. Pump & Boiler Delay DIN Rail Mounting A software option in the thermostat allows The UH8-RF wiring centre can be DIN Rail you to configure which zones are underfloor Mounted for simple, easy installation. heating and which zones are radiators. Radiator zones will not enable the underfloor heating pump and underfloor heating valve where there is a call for heat. The UH8-RF offers an optional pump and boiler delay feature. This 2 minute delay is designed to prevent boilers from going to lockout by giving the zone actuators External Aerial time to open. Our external aerial is designed to work with our UH8-RF wiring centre. Should the Radiator or Underfloor UH8-RF be installed in a metal cupboard A software option in the thermostat allows or where the RF signal is weak, an external you to configure which zones are underfloor aerial can be used. This 3 meter long aerial heating and which zones are radiators. is equipped with a magnetic base for simple Radiator zones will not enable the underfloor installation. It is also perfect for extending heating pump and underfloor heating valve the RF coverage within your property. where there is a call for heat. The UH8-RF wiring centre can be DIN Rail Mounted External for simple, Aerial easy installation. Part Ref: EA1 Wiring centre, controlling up to eight zones Wireless thermostat in each room Product List 8 Zone Wiring Centre (expandable up to 792 Zones) Part Ref: UH8-RF (See page 30) Compatible wireless thermostats Examples: Wireless Slimline Thermostat Part Ref: Slimline-RF Wireless TouchScreen Thermostat Part Ref: Touch-RF (See page 10-11 for Optionalrange) Products complete External Aerial Part Ref: EA1 Optional Products External Aerial Repeater Slimline Wireless Part Ref: EA1 Boost Slimline Wireless Repeater Part Ref: RF Link The UH8-RF works with up to eight compatible wireless thermostats. On demand On from any compatible wireless thermostats. demand zone, a 230v output is provided to switch to the from any zone, a 230v output is provided relevant zone actuator, heating switch the relevant zoneunderfloor actuator, underfloor pump and valve. A volt free connection is heating pump and valve. A volt free supplied foristhe boiler, making it compatible connection supplied for the boiler, making with almost allwith types of boilers. it compatible almost all types of boilers. DIN Rail Mounting External Aerial Part Ref: EA1 Heatmiser Boost The Heatmiser Boost is our surface mount repeater for the RF System, designed to extend the communication distance between the thermostat and receiver. Wireless Water Underfloor Heating & Radiator System 22 neoStat (Timer) neoStat CYLINDER THERMOSTAT A2 NC PRTHW-UWTS PRT-W C (Programmable Wireless Thermostat Inc HW) (Programmable Wireless Thermostat) (Programmable Wireless Thermostat) PRTHW-UWTS (Programmable Wireless Thermostat) BOILER ENABLE L Boiler L N L N 1 PL SL 2 SL FUSE 1 ACTUATORS 1 2 3 4 TIME CLOCK L A1 N A2 ZONE1 L N L N SL 1 SL 1 2 ZONE 2 L N 2 ZONE 3 L N SL 1 2 ZONE 4 L N SL 1 2 A2 ZONE 5 L N SL 1 DHW Zone Valve L N SL FUSE 4 12V FUSE CONTROL 1 2 2 ZONE 6 ZONE 7 FUSE 3 CONTROLS SL 1 FUSE UH3 (TENS) 1 FUSE 5A 800MA MA IN S IN MAINS SUPPLY C B O IL E R UFH PUMP BOILER H/W N L L NO NC L L N N L L ZONE 1 N L SL N L N DHW ZONE1 LZONE N N1 ZONE 2 L N N N L ZONE 4 N N L N L N L NO ZONE LZONE N8 N8 ZONE 6 L N ZONE 5 N L 7 7L ZONE 6 N ZONE ZONE LZONE L 6 N STAT 6 VALVE AND PUMP ENABLE L A2 A1 1 2 3 4 5 6 7 8 9 10 1112 FUSE 2 N N ZONE 7 PUMP VALVE N L L NO L L L N N ZONE 8 L E N E L N VALVE PUMP neoStat (Connected to Zone 8) 230V AC Supply BOILER ENABLE L ZONE 5 5 ZONE ZONE L 4L 4 N ZONE N ZONE ZONE N N33 ZONE 3 N L L N N L MAINS SUPPLY 3 AMP ZONEL22 L ZONE N L BOILER PAIRING YES (UNITS) BOILER RF TEST CREEPAGE ENABLE PUMP DELAY ENABLE NO NC Wireless Antenna ZONE 8 10 Heating or Manifold Valve C 2 BOILER RF TEST CREEPAGE ENABLE UH1-W PUMP DELAYNOENABLE To Boiler Enable N PRT-W (Programmable Wireless Thermostat) (Programmable Wireless Thermostat) ADDRESS (Heating Enable Terminals) E A N L L H PRT-W (Programmable Wireless Thermostat Inc HW) UH8-RF A1 N BOILER ENABLE (VOLT FREE) (Via Heating/Hot Water System Fused Spur) DHW Thermostat A Heating 230V AC Supply PERMANENT LIVE SWITCH LIVE H NO Radiators POWER SUPPLY 3A 230V PRT-W MOTOR FUSE 2A A1 A 1 2 3 4 5 6 7 8 PRT-W N H ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE L neoStat (Connected to Zone 2) (Connected to Zone 1) A H/W P UMP B OIL ER NOT NOT USED USED HOT WATER H VALVE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 H/W PUMP BOILER A 1 2 3 4 5 230VAC H HW STAT LN LN LN LN LN LN LN Radiator Zone Valve (Via Heating/Hot Water System Fused Spur) Radiator Zone Valve ZONE 1 H A To Boiler Enable PRTHW-W Boiler (Programmable Wireless Thermostat) (Heating Enable Terminals) PL SL To Boiler Enable ACTUATOR 230V ACTUATOR 230V Z O NE 4 ACTUATOR 230V ZONE 5 ACTUATOR 230V ACTUATOR 230V RADIATOR VALVE VALVE WITH ENDSWITCH Radiator Zone Valve To Boiler Enable Radiator Zone Valve (Using 230v Actuators) UFM UNDER FLOOR MANIFOLD Standard Products Products Standard NEUTRAL EARTH UFH VALVE To Boiler Enable UFH Manifold LIVE Zone 8 Isolation Switch If set to YES, Zone 8 enables the Boiler Pump and Valve. If set to NO Zone 8 is isolated. (Optional) PERMANENT LIVE SWITCH LIVE UFH PUMP ZONE 7 Z O NE 6 ACTUATOR 230V HOT WATER VALVE Hot Water Control PL SL ACTUATOR 230V ZONEValve 3 Zone ZONE Radiator 2 UFH Manifold (Using 230v Actuators) This equipment should be installed by an appropriately qualified/ registered electrician. Fully read the instructions for proper wiring before applying power. The warranty does not cover damage from improper wiring or installation. END SWITCH AND BOILER ENABLE 8 Zone Wiring Centre Wireless 88Zone Wiring Centre Zone Wiring Centre UH8-RF Part Ref: Heatmiser UH1-W Part Ref: Heatmiser UH3 neoStat (Timer Mode) neoStat (HeatWireless Mode) Slimline Thermostat Part Ref:Ref: Heatmiser PRT-W Part Ref: neoStat Part Slimline-RF Part Ref: neoStat Stylish Thermostats For Modern Living Wireless TouchScreen Thermostat neoHub Part Ref: PRT-UWTS PartHeatmiser Ref: Touch-RF Part Ref: neoHub 23 To Boiler Enable Low Voltage Network Control Solution Total control of your home heating system Use the Heatmiser Touchpad for instant access to your heating system. Headline Information Key Features Providing Complete Network Control Wiring Centre, controlling up to 8 zones 12v Programmable Thermostats in each room Optional Central Control Product List 8 Zone Wiring Centre (expandable up to 32 Zones) Part Ref: Heatmiser UH1 (See page 30) Slimline Thermostat Part Ref: Heatmiser Slimline-N (See page 04-05 for complete slimline range) TouchScreen Thermostat Part Ref: Heatmiser Touch-N (See page 06-07 for complete TouchScreen range) Cable Type Belden 9538 or Cat5(e)-ftp Optional Products 32 zones. What’s more, it provides the ability to control the entire heating system centrally, with the TouchPad. Designed to be used in conjunction with our Slimline or TouchScreen 12v Network Thermostats, our deluxe heating system really is a complete package for those wanting superior control of their heating system. Simple Connectivity The UH1 allows the connection of up to eight 12v Network Thermostats. On demand from any zone, a 230v output is provided to switch pump and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers. Hot Water Control Radiator Zone Control The UH1 also takes care of the hot water. A cylinder thermostat connection and a 230v hot water valve output are provided. Controlling the hot water from A simple slide switch makes zone 8 suitable for controlling a radiator zone. When used for controlling radiators, zone 8 does not enable the wiring, but also because it enables you to control your hot water centrally from the TouchPad and remotely from the NetMonitor. Optional Products Central Control Central Control Part Ref: Heatmiser TouchPad (See page 28-29 for details) Low Voltage Network Control Solution 24 Network Link Central TouchPad Slimline-HWN (Optional Central Control) (To Other UH1 Units) Touch-N (Hot Water Control Thermostat) (TouchScreen Thermostat) Fri 10:23h Y B H + BOILER ENABLE (VOLT FREE) 230V AC Supply (Via Heating/Hot Water System Fused Spur) L - B + Y Y - B A Y + + B - A1 + Y B1 A2 B B2 - - A1 + Y B1 B2 A2 B - Y A1 A2 B + Y A1 A2 B - A1 A2 + Y B TOUCHPAD SLIMLINE-HWN ZONE 1 A2 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 B ZONE 8 H (Heating Enable Terminals) Y A1 NETWORK N Boiler PERMANENT LIVE SWITCH LIVE - FUSE 1 ACTUATORS FUSE 4 12V FUSE CONTROL A Slimline-N (Programmable Thermostat) PL SL Radiator Zone Valve FUSE 3 CONTROLS To Boiler Enable UH1 DHW Zone Valve To Boiler Enable FUSE 2 STAT 6 VALVE AND PUMP Y ENABLE N DHW Thermostat L N ZONE1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 PUMP DHW L SL Zone 8 Isolation Switch If set to YES, Zone 8 enables the Boiler Pump and Valve. If set to NO Zone 8 is isolated. N N L N L N L N L N L N L L VALVE Hot Water Control (Optional) UFH Manifold (Using 230v Actuators) Standard Products 8 Zone Wiring Centre Part Ref: Heatmiser UH1 Stylish Thermostats For Modern Living Slimline Thermostat Part Ref: Heatmiser Slimline-N TouchScreen Thermostat Part Ref: Heatmiser Touch-N 25 Mains Voltage Network System Network control of your mains wired heating system from your Smartphone and Tablet Headline Information Key Features Connections for Neo Network 8 x Zone outputs (suitable for 230v actuators) 230v Output for UHF Pump and Valve control Volt free Boiler Enable The Neo Network System is designed to provide reliable communication of the thermostat data whilst at the same time providing an extended communication range. Each neoStat thermostat acts as a repeater on the network, helping to eliminate range issues which are common on standard RF systems. Component Dimensions UH8 Wiring Center 384 x 148 x 60mm (L,H,D) Providing Wiring centre, controlling up to 8 zones 8 Neo Mains Network Thermostats Easy Upgrade Customers with existing 230v thermostats can upgrade to the Neo Network System and take control of their system from anywhere. The neoHub gateway connects the neoStats to the internet for access via a Smartphone or Tablet both in the home and remotely from anywhere in the world. Neon Indication Neon indicators are provided on the UH8 allowing you to see the power, valve, boiler and zone status without the need to remove the cover. NeoStat Thermostat Flexibility The neoStat can be set to operate in heating or timer mode, allowing the installer to select on installation if the thermostat will be used to control a heating zone or a timed appliance, such as the hot water or perhaps a towel rail. 230v Models Are designed to work with our UH8 wiring centre and dial thermostat with set back function, DIN Rail Mounting The UH8 wiring centre can be DIN Rail Mounted for simple, easy installation. Product List 8 Zone wiring centre Part ref: Heatmiser UH8 (See page 31) 7 x neoStat in Heating mode 1 x neoStat in Timer mode (See page 16-17) NeoHub Optional Products neoX (Range Extender) Heatmiser Boost has been designed the range The neoX to hasextend been designed of Neo System, ensuring to your extend the range of your the can reachthe every Neonetwork system, ensuring part of your network canhome. reach every part of your home. Mains Voltage Network System Simple Connectivity The UH8 allows the connection of up to eight 230v thermostats. On demand from any zone, a 230v output is provided to switch the pump and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers. Radiator Zone Control A simple slide switch make’s zone eight suitable for controlling a radiator zone. When used for controlling radiators, zone 8 does not enable 26 neoStat (Timer) 230VAC UFM UNDER FLOOR MANIFOLD NOT NOT USED USED LIVE L N CYLINDER THERMOSTAT A1 A2 UH8 HOT WATER VALVE neoStat neoStat (Connected to Zone 1) (Connected to Zone 2) NC MOTOR C TIMER LIVE SWITCH LIVE UFH UFH NEO STAT NEO STAT NO UFH UFH HEATING NEO STAT A1 NEO STAT NEUTRAL EARTH POWER SUPPLY 3A 230V BOILER ENABLE END SWITCH AND BOILER ENABLE L N L N A1 A2 - R T 1 R T 2 1 2 L N THREE CORE AND EARTH 1.5 CABLE L N 3 4 TIME CLOCK MAINS SUPPLY L N SL 1 N A1 A2 - R T 1 R T 2 L 2 ZONE1 L L N SL 1 ZONE 2 N A1 A2 - R T 1 R T 2 L N SL 1 2 L 2 ZONE 3 2 ZONE 4 L N SL 1 A2 N A1 A2 - R T 1 R T 2 L L N SL 1 NEO STAT A1 N A2 2 SL 1 ZONE 5 2 L N ZONE 6 L N SL 1 2 N TIME CLOCK E N 1 L E L E ZONE 1 N 1 SL 2 L E ZONE 2 N 1 2 SL L E ZONE 3 N 1 2 SL L N YES ZONE 4 N 1 E 2 SL L E ZONE 5 N 1 2 SL L ZONE 6 N 1 E 2 SL L E E A2 L ZONE 7 1 N 2 A1 SL UFH ZONE 8 N 1 2 SL RAD HEAT ENABLE LS 2 UFH MAINS PUMP SUPPLY LR L IN OUT IS VOLT FREE L E N UFH PUMP BOILER N UFH VALVE GR OR L L L E N N ZONE 1 L ZONE 1 L N N L N L ZONE 2 L N L ZONE 3 L L N N ZONE 4 ZONE 3 ZONE 2 N N ZONE 4 L L N ZONE 5 N ZONE 6 L L N ZONE 6 ZONE 5 N ZONE 7 N L ZONE 8 L L N N L L N ZONE 8 ZONE 7 N L L N N L L N N N neoStat (Connected to Zone 8) LN 230V AC Supply LN LN LN ZONE 2 ZONE 3 ZONE 4 ACTUATOR 230V ACTUATOR 230V ACTUATOR 230V Radiator Zone Valve BOILER (Via Heating/Hot Water System Fused Spur) ENABLE UFH VALVE Boiler UFH PUMP (Heating Enable Terminals) ZONE 1 ACTUATOR 230V PLEASE ADD LINK TO GR AND OR IF VALVE IS NOT FITTED RADIATOR VALVE VALVE WITH Zone 8 Isolation Switch ENDSWITCH If set to YES, Zone 8 enables the Boiler Pump and Valve. If set to NO Zone 8 is isolated. PL SL PL SL PERMANENT LIVE SWITCH LIVE This Equipment should be installed by an appropiately qualified/ registered electrician. Fully read the instructions for proper wiring before applying power. The warranty does not cover damage from improper wiring or installation. UFH Manifold (Using 230v Actuators) Standard Products 8 Zone Wiring Centre Part Ref: Heatmiser UH8 UH3 neoStat (Heat Mode) Part Ref: neoStat Stylish Thermostats For Modern Living neoStat (Timer Mode) Part Ref: neoStat neoHub Part Ref: neoHub 27 To Boiler Enable ZONE 8 TYP E E L NO UH3 L 2 ZONE 8 FUSE Heating or Manifold ValveMAINS 5A FUSE N A1 A2 - R T 1 R T 2 SL 1 ZONE 7 L Central Control Designed to give Central Control within your home Designed to work with our 12v Network Thermostats, the Heatmiser Touchpad provides central control of your home heating system. Headline Information Key Features Central Control Home and Away Holiday Temperature Hold Part Ref: Heatmiser TouchPad This feature gives you a simple Use this function to hold a desired temperature Up to 32 rooms can be controlled from the full colour TFT Display meaning that walking around each room to turn up or down the heating is a thing of the past. system whilst you are away. On your return, pressing the Home button will re-enable the system. Ideal when you have a holiday home and are not sure when you will return. Use the holiday feature to put the heating into frost mode whilst you are away. At the end of the holiday, each room will revert back to the programmed time, ensuring your home is warm on your return. Display TouchScreen 4.3” TFT Colour LCD Number Of Zones 32 (Max) Titles for unexpected activities. Apply to a single or multiple rooms. Copy Facility Auto GMT Correction Gives the ability to store a set of comfort levels for a group of rooms. This setting can be applied as and when required, for example at the start of a new shift. Save time - copy comfort levels between rooms. Automatically adjusts the clocks in all of the thermostats at the start of summer and winter time. History USB Export Key Lock The TouchPad will store hours of temperature history. The temperature log can be exported via the USB connection. Lock each thermostat to prevent misuse. Hot Water Boost Quick View Auto Time Sync Use the hot water boost to quickly override the hot water settings. See at a glance the current thermostat status throughout your building. Syncronises all of the thermostat clocks on the network. Give each room a title Passcode Protect When enabled, the user must enter a passcode in order to access the system. Central Control 28 Intuitive User Interface Interfac Central Control Stylish Thermostats For Modern Living Temperature Hold Home & Away 29 Central Wiring Switch Boxes Multi-zone wiring centres - Designed to Mains make installation Thermostatssimple Compatible Wiring C Our central wiring switch boxes have been designed to simplify the wiring process. Using our wiring centres your application that Our UH2 and UH3 wiring centres areindesigned to work means with our 230v therm the actuator, boiler and pump connections are wired from a single point. and the UH3 for eight zones. 12v Network Thermostat Wiring Centre Wireless 230vWiring 8 ZoneCentre Wiring Centre 230v 4 Zone 230 Part Ref: Heatmiser UH1 Part Ref: Heatmiser UH8-RF UH2 Part The UH1 is designed to be used in conjunction with our 12v network thermostats. The UH1 provides central switching and is therefore ideally as well as providing an output for a hot water cylinder. On demand from any zone, a 230v output is provided to switch the relevant zone actuators, boiler, making it compatible with almost all types of boilers. Up to six actuators can be connected to each zone. An option is provided to turn zone 8 into a not enabled when there is a call for heat from zone 8. The UH8-RF designed be used inwith conjunction with our compatible UH2 canisbe used in to conjunction our mains thermostats. The UH3 is desi wireless The UH8-RF provides switching andas is therefore thermostat (DS The UH2thermostats. provides central switching of up tocentral four zone actuators ideally next to the underfloor heating manifold. Eight zones can be zones can be co well as situated providing an output for a hot water cylinder and the heating controlled as well as providing an output for hot water control. On demand zone allows you from any zone, a 230v is provided to switch control. the relevant is available to use zoneoutput 4 for conventional radiator Up tozone six connections ar actuators, underfloor heatingtopump and valve. A volt free connection is actuators can be connected each zone. supplied for the boiler, making it compatible with almost all types of boilers. and valve. A vo Up to six actuators can be connected to each zone. An external aerial is available all types of boil for use when the UH8-RF is being mounted in a metal cupboard or when the wireless signal is restricted. A software option in the thermostat allows you to valve and boile configure which zones are underfloor heating and which zones are radiators. MAINS SUPPLY BOILER BOILER PRT/HW MAINS SUPPLY PRT PRT/HW PRT PRT PRT PRT PRT TIM THER TIM THER T THERMOSTATS THERMOSTATS ACTUATORS T ACTUATORS ZONE 1 ZONE 1 ZONE 2 ZONE 2 ZONE 3 ZONE 3 ZONE 4 ZONE 4 M MA SU SU HOT WATER HOT WATER PIPE PIPE HOT WATERHOT WATER HEATING HEATING THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT VALVE/PUMP PUMP PUMP VALVE/PUMP Heatmiser UH1 UH1 Heatmiser Central Wiring Switch Boxes Heatmiser UH8-RF Heatmiser UH1-W Heatmiser UH2 Heatmiser UH2 Heatmiser UH2 UH1-W is not suitable for use in Australia New Zealand. UH8-RF is not suitable for useand in Australia. 30 Central CentralWiring WiringSwitch SwitchBoxes Boxes e Wiring Centres Multi-zone Multi-zonewiring wiringcentres centres- Designed - Designedtotomake makeinstallation installationsimple simple with our 230v thermostats. The new UH4 is boxes ideal for smaller systems, uptoto four zones Our Our central central wiring wiring switch switch boxes have have been been designed designed to simplify simplify thethe wiring wiring process. process. Using Using ourour wiring wiring centres centres in your in your application application means means that that thethe actuator, actuator, boiler boiler and and pump pump connections connections areare wired wired from from a single a single point. point. Mains Thermostats Compatible Wiring Centres Our UH4 and UH8 wiring centres are designed to work with our 230v thermostats. The new UH4 is ideal for smaller systems, up to four zones and the UH8 for eight zones. 230v 8 Zone Wiring Centre 12v 12v Network Network Thermostat Thermostat Wiring Wiring Centre Centre Wireless Wireless 230v 230v 8 Zone 8 Zone Wiring Wiring Centre Centre Part Ref: Heatmiser UH8 Part Part Ref: Ref: Heatmiser Heatmiser UH1 UH1 Part Part Ref:Ref: Heatmiser Heatmiser UH8-RF UH8-RF UH8 is designed The UH3 toiswork with to ourbe channel 230v timewith clock and 230v Set back TheThe UH1 UH1 designed is designed tofour be used used in conjunction in conjunction with our(TM4) our 12v12v network network TheThe UH8-RF UH8-RF is designed is designed to be to be used used in conjunction in conjunction with with ourour compatible compatible 230v 4 Zone Wiring Centre 230v 8 Zone Wiring Centre Up to thermostat (DS-SB) but equally could be usedcentral with any 230v room thermostat. Upideally toeight eight thermostats. thermostats. TheThe UH1 UH1 provides provides central switching switching andand is therefore is therefore ideally wireless wireless thermostats. thermostats. TheThe UH8-RF UH8-RF provides provides central central switching switching andand is therefore is therefore Part Ref: Heatmiser UH4 Part Ref: Heatmiser UH8 UH8. On zones can be controlled from the UH3. Onboard boardthe theUH8 UH3are aretwo twoheating heatingtime timechannels, channels,each each ideally ideally situated situated next next to the to the underfloor underfloor heating heating manifold. manifold. Eight Eight zones zones cancan be be zone allows you towell specify which an time channel it should follow. Two additional time channel as well as as providing as providing an output output for for a hot a hot water water cylinder. cylinder. OnOn demand demand from from controlled controlled as well as well as providing as providing an an output output for for hothot water water control. control. OnOn demand demand connections are provided hot water control orto other auxiliary devices. On demand from any from anyany zone, zone, a 230v afor 230v output output is provided is provided switch to switch thethe relevant relevant zone zone actuators, actuators, from anyany zone, zone, a 230v a 230v output output is provided is provided to switch to switch thethe relevant relevant zone zone The UH4 can be used in conjunction with our 230v mains thermostats. The UH3 is designed to work with our four channel 230v time clock (TM4) and 230v Set back zone, a 230v output is provided to switch the relevant zone actuator, underfloor heating pump actuators, actuators, underfloor underfloor heating heating pump pump andand valve. valve. A volt A volt freefree connection connection is is The UH4 provides central switching of up to four zones as well as thermostat (DS-SB) but equally could be used with any 230v room thermostat. Up to eight free connection isissupplied for the boiler, ititboilers. compatible with almost and valve. AAvolt voltboiler, free connection supplied foralmost the boiler, making compatible with almost boiler, making making it compatible it compatible with with almost all types allmaking types of boilers. of UpUp to six to six actuators actuators supplied supplied for for thethe boiler, boiler, making making it compatible it compatible with with almost almost all types all types of boilers. of boilers. providing an output for hot water, system boiler and pump. zones can be controlled from the UH3. On board the UH3 are two heating time channels, each simple slide makes 88suitable for aaradiator all types of boilers. simple slide switch makes zone suitable forcontrolling controlling radiator zone. cancan beAAbe connected connected toswitch each to each zone. zone. Anzone An option option is provided is provided to turn to turn zone zone 8 into 8 into a zone. a UpUp to six to six actuators actuators cancan be be connected connected to each to each zone. zone. An An external external aerial aerial is available is available When used for underfloor heating, an option is available to use zone allows you to specify which time channel it should follow. Two additional time channel When used for controlling radiators, zone 8 does not enable the underfloor heating pump, for for useuse when when thethe UH8-RF UH8-RF is being is being mounted mounted in ainmetal a metal cupboard cupboard or when or when thethe zone 4 for conventional radiator control. Up to six actuators connections are provided for hot water control or other auxiliary devices. On demand from any Up to actuators can be connected to each zone. valve and boiler. Upenabled tofour four actuators can be connected to each zone. notnot enabled when when there there is aiscall a call for for heat heat from from zone zone 8. 8. wireless wireless signal signal is restricted. is restricted. A software A software option option in the in the thermostat thermostat allows allows youyou to to can be connected to each zone. configure configure which which zones zones areare underfloor underfloor heating heating andand which which zones zones areare radiators. radiators. and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers. A simple slide switch makes zone 8 suitable for controlling a radiator zone. TIME CLOCK THERMOSTAT DIAL TYPE THERMOSTAT DIAL TYPE THERMOSTAT MAINS PRT/HW PRT SUPPLY DS-SB DS-SB BOILER TM4 DIAL TYPE THERMOSTAT PRT DS-SB valve and boiler. Up to four actuators can be connected to each zone. NO PRT YES VALVE MAINS SUPPLY TO BOILER ZONE 1 ZONE 2 THERMOSTATS ACTUATORS SUPPLY TO SUPPLY TO ACTUATORS ACTUATORS UFH UFH OR VALVES PUMP ZONE 1 VALVE ZONE 2 OR VALVES ZONE 3 ZONE 4 TIME CLOCK THERMOSTAT DIAL TYPE THERMOSTAT DIAL TYPE THERMOSTAT DIAL TYPE THERMOSTAT TM4 DS-SB DS-SB DS-SB ZONE 8 NO YES SUPPLY TO ACTUATORS OR VALVES VALVE Heatmiser Heatmiser UH1 UH1 Heatmiser Heatmiser UH1 UH1 Heatmiser UH3 Heatmiser UH8 HOT WATER THERMOSTAT HOT WATER VALVE/PUMP HEATING PUMP PIPE THERMOSTAT Heatmiser HeatmiserUH2 UH4 Stylish Thermostats For Modern Living ZONE 1 ZONE 2 ZONE 8 Heatmiser Heatmiser UH8-RF UH8-RF Heatmiser Heatmiser UH1-W UH1-W UH1-W UH1-W is not is suitable notnot suitable for use for in useAustralia in Australia and and New New Zealand. Zealand. UH8-RF UH8-RF is is not suitable suitable for for useuse in Australia. in Australia. MAINS SUPPLY TO BOILER UFH PUMP UFH VALVE SUPPLY TO ACTUATORS OR VALVES SUPPLY TO ACTUATORS OR VALVES SUPPLY TO ACTUATORS OR VALVES Heatmiser UH3 Heatmiser UH8 31 Stylish Thermostats For Modern Living Heatmiser UK Ltd 8 & 9 Hurstwood Court, Mercer Way Shadsworth Business Park, Blackburn Lancashire. BB1 2QU, England Tel: +44 (0)1254 669090 Fax: +44 (0)1254 669091 Email: [email protected] Registered in England: 3747773 www.heatmiser.com Twitter: @heatmiseruk Facebook: facebook.com/thermostats 09/15 WEEE Registration Number: WEE/GF0052TQ