120109-BAC-CF-H2018-B01X ENG.cdr

Transcription

120109-BAC-CF-H2018-B01X ENG.cdr
Ceiling floor split air conditioners
Blaupunkt series Intercooler CF
Sales start
January 2012
Order numbers
BAC-CF-H2018-B01X
BAC-CF-H2624-B01X
BAC-CF-H3936-B01X
BAC-CF-H5248-B01X
EAN numbers
Highlights
Universal installation
Functions
EU energy label (efficiency class)
Max. noise level
Refrigerant
COP (heating)
EER (cooling)
Large air circulation
Effective ventilation
Remote control
Outdoor unit of series U1
Design„Intercooler CF”
Warranty
www.blaupunkt.de
vertical or horizontal
cooling and heating
A
38/43/44/45 dB (A)
R410A (environment-friendly)
3.42 – 2.85
2.97 – 2.72
3
790/1100/1700/2300 m /h
multilayered double
system of louvers
intelligent management function
full selection of power ranges
from 5 to 17 kW
by Blaupunkt
24 months
Ceiling floor split air conditioners
Blaupunkt series Intercooler CF
Blaupunkt model
BAC-CF-H2018-B01X
EAN number
Heating
BAC-CF-H3936-B01X
BAC-CF-H5248-B01X
5902596575168
5902596575175
5902596575182
5902596575199
V/Ph/Hz
220~240V/1Ph/50Hz
220~240V/1Ph/50Hz
220~240V/1Ph/50Hz
380~415V/3Ph/50Hz
Cooling capacity
Btu/h
18000
24000
36000
48000
kW
5.3
7.1
10.5
14
EER
W/W
2.97
2.80
2.77
2.72
Heating capacity
Btu/h
19800
26000
39000
52500
kW
5.8
7.8
11.6
15.4
COP
W/W
3.4
3.36
3.42
2.85
W
65
150
300
165+165
Power supply
Cooling
BAC-CF-H2624-B01X
Indoor fan
Power
Evaporator
Fin type
hydropholic
Dimensions (L x H x D)
610 x 255 x 66
982 × 250 × 43.3
982 × 250 × 64.95
1403 × 250 × 43.3
790/670/540
1100/860/740
1700/1300/1100
2300/1900/1500
m3/h
Air circulation
Noise level (high/medium/low)
dB(A)
Indoor unit
mm
Dimensions (L x H x W)
Net/gross weight
Liquid/gas
hydropholic
hydropholic
48/46/44
52/48/45
57/54/52
1245 × 680 × 247
1245 × 680 × 247
1670 × 680 × 247
35/41
37/43
47/54
kg
30/32
R410A
R410A
R410A
R410A
mm
Φ6.35/Φ12.7
Φ9.52/Φ15.88
Φ9.52/Φ19.05
Φ9.52/Φ19.05
Refrigerant
Pipe installation
52/48/44
880 × 635 × 203
hydropholic
Condensate installation
mm
30
30
30
30
Wiring
Power supply
mm2
2.5
2.5
4
2.5
Communication
mm 2
Control system
1.5
0.75
0.75
0.75
Remote control
Remote control
Remote control
Remote control
Temperature range
°C
16 ~ 32
16 ~ 32
16 ~ 32
16 ~ 32
Range of outdoor temperature
°C
-7 ~ 43
-7 ~ 43
-7 ~ 43
-7 ~ 43
BAC-U1-H18R-01X
BAC-U1-H24R-01X
BAC-U1-H36R-01X
BAC-U1-H48R-01X
5902596575014
5902596575021
5902596575038
5902596575045
V/Ph/Hz
220~240V/1Ph/50Hz
220~240V/1Ph/50Hz
380-415V/3Ph/50Hz
380~415V/3Ph/50Hz
Cooling capacity
kW
5.3
7.1
10.5
14
Power consumption
W
1900
2400
3800
5000
Current input
A
7.35
9.2
6.5
8.4
Heating capacity
kW
5.8
7.81
11.55
15.4
Power consumption
W
1690
2100
3600
5100
Current input
A
7.35
9.2
6.5
8.4
W
2500
2700
4900
6000
Blaupunkt model
EAN number
Power supply
Cooling
Heating
Max. power consumption
Compressor
Type
Rotary
Rotary
Rotary
Rotary
Made
HITACHI
HITACHI
SANYO
SANYO
W
1900
2200
3650
4750
Air circulation
3
m /h
2800
3800
6000
6100
Noise level
dB(A)
53
65
65
Power consumption
Outdoor unit
Dimensions (L*H*D)
Net/gross weight
Refrigerant type/amount
Pipe installation
Refrigerant/gas
Max. installation length
Max. height difference
Outdoor temperature range
mm
866 × 535 × 304
930 × 700 × 370
1070 × 995 × 400
60
911 × 1335 × 400
kg
49/51
58/61
92/100
96/107
g
R410A/1200
R410A/1800
R410A/2100
R410A/3600
mm
φ6.35/φ12.7
Φ9.52/Φ15.88
Φ9.52/Φ19.05
Φ9.52/Φ19.05
m
20
20
20
20
m
12
12
12
12
°C
-7 ~ 43
-7 ~ 43
-7 ~ 43
-7 ~ 43
Blaupunkt Competence Center Aircons & Solar Cooling Mateko Sp. z o.o.
Tel. 022 519 73 63 [email protected], www.blaupunkt.de