topjob ® s

Transcription

topjob ® s
TOPJOB®
The Rail-Mounted Terminal Block System​
1
The range of rail-mounted terminal blocks
for a perfect electrical installation
Largest portfolio of rail-mounted terminal blocks 4
TOPJOB®S technology 6
Smallest to the largest 8
smartPRINTERTM by WAGO
10
TOPJOB®S jumper system
12
XCOM®S pluggable system
14
Special function terminal blocks
16
TOPJOB®S benefits at a glance
18
Rail-mounted terminal blocks 16 AWG / 1.0 (1.5) mm2 20
Rail-mounted terminal blocks 14 AWG / 1.5 (2.5) mm2 21
Rail-mounted terminal blocks 12 AWG / 2.5 (4) mm 23
Rail-mounted terminal blocks 10 AWG / 4 (6) mm2 24
Rail-mounted terminal blocks 8 AWG / 6 (10) mm2 25
2
Rail-mounted terminal blocks 6 AWG / 10 (16) mm2 26
Rail-mounted terminal blocks 4 AWG / 16 (25 "f-st") mm2 27
35° Rail-mounted terminal blocks 12 AWG / 2.5 (4) mm2 28
Test plug adapter and testing tap, push-in type wire jumpers,
motor configuration jumpers
29
Vertical jumpers, colored jumpers, endless jumpers
30
Modular connectors
31
Double deck terminal blocks 16 AWG / 1 (1.5) mm 35
2
Double deck terminal blocks 12 AWG / 2.5 (4) mm2 37
Double deck terminal blocks: 4 conductors per deck
39
Triple deck terminal blocks 12 AWG / 2.5 (4) mm 40
2
Motor terminal blocks 12 AWG / 2.5 (4) mm241
Disconnect terminal blocks for test
and measurement 12 AWG / 2.5 (4) mm2 44
Double deck disconnect terminal blocks for test
and measurement 12 AWG / 2.5 (4) mm2 47, 54
Fuse terminal blocks 12 AWG / 2.5 (4) mm 48
2
Double deck fuse and disconnect blocks
12 AWG / 2.5 (4) mm254
Disconnect terminal blocks for test and measurement
8 AWG / 6 (10) mm257
Fuse terminal blocks 8 AWG / 6 (10) mm260
Plug-in component modules
66
Diode and LED terminal blocks 14 AWG / 1.5 (2.5) mm272
Diode and LED terminal blocks 12 AWG / 2.5 (4) mm273
Double deck diode and LED terminal blocks
12 AWG / 2.5 (4) mm2 74
Triple deck diode and LED terminal blocks
12 AWG / 2.5 (4) mm2 76
X-COM®S terminal blocks 16 AWG / 1.0 (1.5) mm2
80
X-COM S terminal blocks 12 AWG / 2.5 (4) mm
86
®
Oversized end plates/separators
2
92
Mounting accessories and stickers for operating instructions93
Ferrules and crimping tools94
Marking of terminal blocks96
List of approvals102
4
The Industry‘s Largest Portfolio for Industrial,
Process and Transportation Applications​
Industry‘s widest range of conductor sizes:
24 AWG - 350 kcmil (0.14–185 mm2)​
Comprehensive range of feed-through and
special function terminal blocks​
Connect all conductor types​
5
TOPJOB®S – Vibration-Proof,
WAGO – The Spring Pressur
Simply
pushed in!​
Simple, push-in termination of
solid and ferruled conductors –
no operating tool needed​
Save time!​
Reduce wiring time by
up to 75%
Always
reliable!​
Just like the original CAGE CLAMP® (patented in 1977),
TOPJOB®S with CAGE CLAMP®S ensures reliability with
spring pressure connection technology that automatically
adjusts for environmental influences such as temperature
cycling and vibration
6
, Fast, Maintenance-Free​
e Connection Technology​
What does this mean for you?​
• Maintenance-free connections – wire it once and forget it
• Wiring independent of operator skill – no torque values or special tools needed
• Eliminate service calls due to loose connections
• Corrosion-resistant, gas-tight connections for corrosive atmospheres
Both hands free
for faster wiring!​
CAGE CLAMP®S for all conductor types​
Simple, push-in termination of solid and
ferruled conductors​
Once inserted, the operating tool holds the spring
open allowing the use of both hands for wiring
7
POWER CAGE CLAMP®
• The industry’s first and only spring pressure
terminal block for 350 kcmil
• See www.wago.us/powercageclamp.htm
8
The Smallest, the Biggest and
Always the Right Terminal Blocks​
The Smallest
• Maximizes cabinet space
• Up to 16 AWG (1.5 mm2) at 600V/10A
The Biggest
• Wire size up to 350 kcmil (185 mm2)
• Terminate large conductors with a single turn
• 8 - 2 AWG (35 mm2) up to 600V/115A
• 8 AWG – 2/0 (50 mm2) up to 600V/150A
• 4 AWG – 4/0 (95 mm2) up to 600V/200A​
• 1/0 - 350 kcmil (185 mm2) up to 1000V/310A
And In Between
• Including feed-through, ground, double deck, triple deck,
pluggable, fuse, disconnect, LED and diode terminal blocks
Industry‘s widest range of spring pressure
terminal blocks
For conductor sizes 24 AWG – 350 kcmil (0.14-185 mm2)​
Save additional space with the use of multi-level terminal
blocks (up to 66%)
9
smartPRINTERTM by WAGO –
The Fastest and Most Efficient Marking System​
• Print on both strip and tag style
terminal block markers; as well as
wire markers, push button plates
and adhesive labels
• Multi-line marking capable – more
detail means less wiring errors
• Clear, smudge free thermal printing
– no drying time
• All marking material on continuous
reel – reduces reload for faster
marking
• Mark up to 9,615 terminal blocks on
a single reel
10
Industry exclusive continuous marker strip with
multi-line marking
One system for all marking requirements:
components, wire marking, etc.
Printing software integrated in “free of charge”
ProServe engineering tool
Watch us go from 0 to 100 in 10 seconds:
www.smartprinter.us/video
11
TOPJOB®S Jumper System​
Ready to Solve Any Commoning Tasks​
WAGO’s range of jumpers
provide the greatest possibilities and convenience:​
Multi-pole, push-in jumpers can
be easily customized by removing
a single contact leg (factory preconfigured jumpers also available).
Unique solutions include Delta or
Wye motor wiring.​
Push-In Type Jumper Bars
Jumper Retention Spring
12
Endless jumpers for endless possibilities. This two position adjacent
jumper takes up only jumper slot
and allows continuous commoning
– no limits. ​
Adjacent Jumpers for
Continuous Commoning
Our step-down jumpers easily
common terminal blocks rated for
different conductors sizes (e.g.
POWER CAGE CLAMP® rated
8 - 2 AWG to TOPJOB®S Series
2010 rated 20 - 6 AWG). Resulting in a cost saving and modular
approach for power distribution
applications.
Step-Down Jumper
Using push-in type wire jumpers, commoning over longer
distances, across multiple levels, or
around plug-in component accessories is easily achieved.​
Slim style jumpers are similar to
our standard multi-pole jumpers,
except they are thinner to accommodate alternate commoning
within a single jumper slot row, offering an industry best commoning
of up to 4 different potentials.
The perfect solution for multi-level
terminal blocks: Vertical jumpers
easily connect two or three levels
within a single terminal block.
Vertical Jumper
Slim Style Jumper
Push-In Type Wire Jumper
Exclusive jumper retention spring – ensures reliable
commoning​
Comprehensive jumper system for virtually any
application
Minimum two jumper slots on every terminal block
Simple, easy to use push-in design
13
X-COM®S and TOPJOB®S
Create Synergies​
X-COM®S: Pluggable Connector
System for Modular Rail-Mounted
Terminal Blocks
Benefits of Pre-harnessed Assemblies:​
• Connectorize your test fixture…plug-in, test,
un-plug and ship
• Fast and error free wiring during equipment
dismantle and assembly
• Cost effective alternative to rectangular
connectors
Features of X-COM®S:​
• Protection against accidental contact in
the un-mated condition
• Coding provides protection against
mis-mating
• Marking on both connector and terminal
block for fast reliable connections
• Industry’s first and only 3.5mm wide
pluggable rail mounted terminal block
14
Common profile makes
X-COM®S and TOPJOB®S
compatible for:​
•Commoning
•Marking
Benefit from pre-harnessed assemblies​
Protection against accidental contact
Coding provides additional safety
15
Comprehensive Range of Sp
For Application Specific Sol
Disconnect Terminal
Blocks​
• Isolation of a circuit for test and
measurement of a signal
• Plug-in and knife pivot disconnect
versions
• Available in single and multi-level
terminal blocks
Easy self-assembly of component plugs​
Wide variety of function terminal blocks​
Disconnect terminal block up to 1,000 V
(e.g., photovoltaic applications)​
16
ecial Function Terminal Blocks –
utions
Component Plugs for Self-Assembly​
• Creation of a custom circuit containing
diode, LED, resistor, etc.
• Single and multi-level carrier terminal
blocks to accept component plugs
• Component plugs also available for
plug-in to the existing jumper slot of
terminal blocks
Fuse Terminal Blocks​
• Protection of a circuit
• Plug-in and pivot style fuse terminal
blocks for glass fuses (5 x 20mm and
¼ x 1¼) and auto style fuses
• Available in single and multi-level
terminal blocks with and without blown
fuse indication
Diode and LED Terminal Blocks​
• Polarity protection and status indication
of a circuit
• Available in single and multi-level
terminal blocks
• Custom solutions available – contact
factory
17
Benefits at a Glance​
18
The Industry‘s Largest Portfolio for Industrial, Process and Transportation Applications​
Industry‘s widest range of conductor sizes: 24 AWG - 350 kcmil (0.14–185 mm2)​
Comprehensive range of feed-through and special function terminal blocks​
Connect all conductor types​
TOPJOB®S – Vibration-Proof, Fast, Maintenance-Free
WAGO – The Spring Pressure Connection Technology​
CAGE CLAMP®S for all conductor types​
Simple, push-in termination of solid and ferruled conductors​
Once inserted, the operating tool holds the spring open allowing the use of both hands for wiring
The Smallest, the Biggest and Always the Right Terminal Blocks​
Industry‘s widest range of spring pressure terminal blocks
For conductor sizes 24 AWG – 350 kcmil (0.14-185 mm2)​
Save additional space with the use of multi-level terminal blocks (up to 66%)
smartPRINTERTM by WAGO – The Fastest and Most Efficient Marking System​
Industry exclusive continuous marker strip with multi-line marking
One system for all marking requirements: components, wire marking, etc.
Printing software integrated in “free of charge” ProServe engineering tool
TOPJOB®S Jumper System
Ready to Solve Any Commoning Tasks​
Exclusive jumper retention spring – ensures reliable commoning​
Comprehensive jumper system for virtually any application
Minimum two jumper slots on every terminal block
Simple, easy to use push-in design
X-COM®S and TOPJOB®S Create Synergies​
Benefit from pre-harnessed assemblies​
Protection against accidental contact
Coding provides additional safety
Comprehensive Range of Special Function Terminal Blocks –
For Applications​Specific Solutions
Easy self-assembly of component plugs​
Wide variety of function terminal blocks​
Disconnect terminal block up to 1,000 V (e.g., photovoltaic applications)
19
?
Rail-Mounted Terminal Blocks 1.0 (1.5) mm2/AWG 16
2000 Series
0.14–1.0(1.5) mm2
800 V/6 kV/3 IN 13.5 A (18 A)
AWG 24 – 16
600 V, 10 A U
600 V, 10 A 2
Terminal block width 3.5 mm / 0.137 in
L 9 – 11 mm / 0.39 in
0.14 –1.0( 1.5) mm2
800 V/6 kV/3 IN 13.5 A (18 A)
AWG 24 – 16
600 V, 10 A U
600 V, 10 A 2
Terminal block width 3.5 mm / 0.137 in
L 9 – 11 mm / 0.39 in
0.14 –1.0( 1.5) mm2
800 V/6 kV/3
IN 13.5 A (18 A)
AWG 24 – 16
600 V, 10 A U 600 V, 10 A 2
Terminal block width 3.5 mm / 0.137 in
L 9 – 11 mm / 0.39 in
<____ 48.5 mm /1.91 in ____>
ItemPack.-unit
No.pcs
4
4
4
4
4
4
2-conductor through terminal blocks
2000-1201
gray
blue
2000-1204 2
2000-1202
orange
red
2000-1203
black 2000-1205
yellow
2000-1206
4
2-conductor ground (earth) terminal block
2000-1207
green-yellow
ItemPack.-unit
No.pcs
4
4
4
4
4
4
100
100
100
100
100
100
3-conductor through terminal blocks
2000-1301
gray
blue
2000-1304 2
2000-1302
orange
red
2000-1303
black 2000-1305
yellow
2000-1306
100
3-conductor ground (earth) terminal block
2000-1307
green-yellow
Suitable for Ex i applications
<____________ 68 mm /2.67 in ____________>
4
ItemPack.-unit
No.pcs
4
4
4
4
4
4
100
100
100
100
100
100
4-conductor through terminal blocks
2000-1401
gray
blue
2000-1404 2
2000-1402
orange
red
2000-1403
black
2000-1405
yellow
2000-1406
100
4-conductor ground (earth) terminal block
2000-1407
green-yellow
4
2 Suitable for Ex i applications
2 Suitable for Ex i applications
Item-Specific Accessories
Item-Specific Accessories
Item-Specific Accessories
End and intermediate plate, 0.7 mm thick
orange 2000-1292100 (4 x 25)
gray
2000-1291100 (4 x 25)
End and intermediate plate, 0.7 mm thick
orange 2000-1392100 (4 x 25)
gray
2000-1391100 (4 x 25)
2000 Series Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Push-in type jumper bar, insulated,
IN 14 A
light gray
2-way 2000-402200 (8 x 25)
3-way 2000-403200 (8 x 25)
4-way 2000-404200 (8 x 25)
5-way 2000-405100 (4 x 25)
6-way 2000-406100 (4 x 25)
7-way 2000-407100 (4 x 25)
8-way 2000-408100 (4 x 25)
9-way 2000-409100 (4 x 25)
10-way 2000-410100 (4 x 25)
Push-in type jumper bar, insulated,
IN 14 A
light gray
from 1-3 2000-433200 (8 x 25)
from 1-4 2000-434200 (8 x 25)
from 1-5 2000-435100 (4 x 25)
from 1-6 2000-436100 (4 x 25)
from 1-7 2000-437100 (4 x 25)
from 1-8 2000-438100 (4 x 25)
from 1-9 2000-439100 (4 x 25)
from 1-10 2000-440100 (4 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow
2000-115 100 (4 x 25)
Delta jumper, insulated,
IN = IN terminal block, light gray
1-2 3-4 5-6 2000-406/020-000
100 (4 x 25)
Star point jumper, insulated,
IN = IN terminal block, light gray
1-3-52000-405/011-000
100 (4 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap, for max. 2.5 mm2
Banana plug,
for socket 4 mm Ø
color mixed
215-111 50
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
Testing plug,
with 500 mm cable,
2 mm Ø
210-136 50
red
Testing plug,
with 500 mm cable,
2.3 mm Ø
210-137 50
yellow
20
<_______ 59.5 mm /2.34 in ________>
mm /
<___ 33
1.3 in ___>
mm /
<___ 33
1.3 in ___>
mm /
<___ 33
1.3 in ___>
2000 Series terminal blocks can accomodate: 0.14mm2 (24 AWG) - 1.5mm2 (16 AWG) solid or stranded wire;
or direct insertion of: 0.5mm2 (20 AWG) - 1.5mm2(16 AWG) solid or 0.5mm2 (20 AWG) - 0.75mm2 (18AWG) stranded wire with ferrule (10mm barrel length)
2
100
100
100
100
100
100
100
End and intermediate plate, 0.7 mm thick
orange 2000-1492100 (4 x 25)
gray
2000-1491100 (4 x 25)
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
for 3.5 mm terminal block width
plain
793-3501
5
?
Rail-Mounted Terminal Blocks 1.5 (2.5) mm2/AWG 14
2001 Series
2
0.25 –1.5 (2.5) mm AWG 22 – 14
800 V/8 kV/3 600 V, 15 A U
18 A
600 V, 15 A 2
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
0.25 –1.5 (2.5) mm2 AWG 22 – 14
800 V/8 kV/3 600 V, 15 A U
18 A
600 V, 15 A 2
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
2
0.25 –1.5 (2,5) mm AWG 22 – 14
800 V/8 kV/3 600 V, 15 A U
18 A
600 V, 15 A 2
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
ItemPack.-unit
No.pcs
4
4
4
4
4
4
2-conductor through terminal blocks
2001-1201
gray
blue
2001-1204 2
2001-1202
orange
red
2001-1203
black
2001-1205
yellow
2001-1206
100
100
100
100
100
100
4
<_______ 59.5 mm /2.34 in ________>
ItemPack.-unit
No.pcs
4
4
4
4
4
4
3-conductor through terminal blocks
2001-1301
gray
blue
2001-1304 2
2001-1302
orange
red
2001-1303
black
2001-1305
yellow
2001-1306
100
100
100
100
100
100
4
4
<_12 _>
mm/
<___ 33
1.3 in ___>
4
<____ 48.5 mm /1.91 in ____>
mm /
<___ 33
1.3 in ___>
4
mm /
<___ 33
1.3 in ___>
2001 Series terminal blocks can accomodate: 0.25mm2 (22 AWG) - 2.5mm2 (14 AWG) solid or stranded wire;
or direct insertion of: 0.5mm2 (20 AWG) - 2.5mm2 (14 AWG) solid or 0.75mm2 (18 AWG) - 1.5mm2 (16AWG) stranded wire with ferrule (12mm barrel length)
<____________ 70 mm /2.76 in ____________>
ItemPack.-unit
No.pcs
4
4
4
4
4
4
4-conductor through terminal blocks
2001-1401
gray
blue
2001-1404 2
2001-1402
orange
red
2001-1403
black
2001-1405
yellow
2001-1406
100
100
100
100
100
100
4
2-conductor ground (earth) terminal block
2001-1207
100
green-yellow
Suitable for Ex e II applications 550 V, 17 A
2 Suitable for Ex i applications
3-conductor ground (earth) terminal block
2001-1307
100
green-yellow
Suitable for Ex e II applications 550 V, 17 A
2 Suitable for Ex i applications
4-conductor ground (earth) terminal block
2001-1407
100
green-yellow
Suitable for Ex e II applications 550 V, 17 A
2 Suitable for Ex i applications
Item Specific Accessories
Item Specific Accessories
Item Specific Accessories
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1292100 (4 x 25)
gray
2002-1291100 (4 x 25)
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1392100 (4 x 25)
gray
2002-1391100 (4 x 25)
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1492100 (4 x 25)
gray
2002-1491100 (4 x 25)
4
4
4
Oversized endplates and sperator plates on page 92
2001 Series Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Push-in type jumper bar, insulated,
IN 18 A
light gray
2-way 2001-402200 (8 x 25)
3-way 2001-403200 (8 x 25)
4-way 2001-404200 (8 x 25)
5-way 2001-405100 (4 x 25)
6-way 2001-406100 (4 x 25)
7-way 2001-407100 (4 x 25)
8-way 2001-408100 (4 x 25)
9-way 2001-409100 (4 x 25)
10-way 2001-410100 (4 x 25)
Push-in type jumper bar, insulated,
IN 18 A
light gray
from 1-3 2001-433200 (8 x 25)
from 1-4 2001-434200 (8 x 25)
from 1-5 2001-435100 (4 x 25)
from 1-6 2001-436100 (4 x 25)
from 1-7 2001-437100 (4 x 25)
from 1-8 2001-438100 (4 x 25)
from 1-9 2001-439100 (4 x 25)
from 1-10 2001-440100 (4 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow
2001-115 100 (4 x 25)
Step-down jumper, insulated,
IN 32 A
light gray 2006-499 50 (2 x 25)
Insulation stop,
5 pcs/strip,
0.25 - 0.5 mm2
light gray 2001-171200 (8 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap, for max. 2.5 mm2
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
Testing plug,
with 500 mm cable,
2 mm Ø
210-136 50
red
Testing plug,
with 500 mm cable,
2.3 mm Ø
210-137 50
yellow
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 4 - 4.2 mm
plain
793-4501
5
WMB Inline, plain,
stretchable 4 - 4.2mm,
2,000 WMB markers, 4mm, on roll
white
2009-114 1
Modular TOPJOB®S connector,
can be snapped together,
for jumper contact slot
gray
2001-511100 (4 x 25)
Spacer module, can be snapped together,
e.g., for bridging commoned
terminal blocks
gray
2001-549100 (4 x 25)
End plate,
for modular TOPJOB®S connectors,
1.5 mm thick
gray
2002-541100 (4 x 25)
21
?
Double Potential Terminal Blocks
2000 Series
2001 Series
<___________ 85.9 mm /3.38 in ____________>
ItemPack.-unit
No.pcs
Double potential terminal block,
both potentials can be commoned
2000-2141
gray 0.25 –1.5 (2.5) mm2 AWG 22 – 14
800 V/8 kV/3 600 V, 15 A U
IN 18 A (24 A)
600 V, 15 A 2
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
<____________ 70 mm /2.76 in ____________>
ItemPack.-unit
No.pcs
Double potential terminal block,
2001-1441
gray 100
mm /
<___ 37.5
1.48 in ___>
<____________ 70 mm /2.76 in ____________>
ItemPack.-unit
No.pcs
Double potential terminal block,
2002-1441
gray 100
50
Attention! This double potential terminal block cannot be
commoned with push-in type jumper bars!
Attention! This double potential terminal block cannot be
commoned with push-in type jumper bars!
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 0.7 mm thick
orange 2000-2196100 (4 x 25)
gray
2000-2195100 (4 x 25)
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1492100 (4 x 25)
gray
2002-1491100 (4 x 25)
200 strips
Insulation stop, 5 pcs/strip
light gray2001-171 0.25-0.5 mm2
Double potential terminal blocks are space savers. Two independent through terminal blocks are
placed in one insulated housing on one level.
Input and output contacts of one circuit are
placed on the same side of the terminal block.
Both circuits can be individually marked according to input and output.
22
AWG 22 – 12
0.25 –1.5 (4) mm2 800 V/8 kV/3 600 V, 20 A U
IN 24 A (32 A)
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
mm /
<___ 37.5
1.48 in ___>
mm /
<___ 32.5
1.28 in ___>
0.14–1(1.5) mm2 AWG 24 – 16
800 V/8 kV/3 IN 13.5 A (18 A)
Terminal block width 3.5 mm / 0.138 in
L 9 – 11 mm / 0.39 in
2002 Series
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1492100 (4 x 25)
gray
2002-1491100 (4 x 25)
200 strips
Insulation stop, 5 pcs/strip
light gray2002-171 0.25-0.5 mm2
dark gray2002-172 0.75-1 mm2
Protective warning marker,
for 5 terminal blocks
yellow 2002-115100 (4 x 25)
?
Rail-Mounted Terminal Blocks 2.5 (4) mm2/AWG 12
2002 Series
2
AWG 22 – 12
0.25 – 2.5 (4) mm 800 V/8 kV/3 600 V, 20 A U
24 A
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3 600 V, 20 A U
24 A
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3 600 V, 20 A U
24 A
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<____ 48.5 mm /1.91 in ____>
ItemPack.-unit
No.pcs
<________ 59.5 mm /2.34‑in _________>
4
4
4
4
4
4
ItemPack.-unit
No.pcs
4
<_____________ 70 mm /2.76 in _____________>
4
4
4
4
4
4
<_12 _>
mm /
<___ 33
1.3 in ___>
4
mm /
<___ 33
1.3 in ___>
4
mm /
<___ 33
1.3 in ___>
2002 Series terminal blocks can accomodate: 0.25mm2 (22 AWG) - 4mm2 (12 AWG) solid or stranded wire;
or direct insertion of: 0.75mm2 (18 AWG) - 4mm2 (12 AWG) solid or 0.75mm2 (18 AWG) - 2.5mm2 (14 AWG) stranded wire with ferrule (12mm barrel length)
ItemPack.-unit
No.pcs
4
4
4
4
4
4
2-conductor through terminal blocks
3-conductor through terminal blocks
4-conductor through terminal blocks
2002-1201
100
gray
2002-1301
100
gray
2002-1401
100
gray
blue
2002-1204 2
100
blue
2002-1304 2
100
blue
2002-1404 2
100
2002-1202
100
orange
2002-1302
100
orange
2002-1402
100
orange
red
2002-1203
100
red
2002-1303
100
red
2002-1403
100
black 2002-1205
100
black 2002-1305
100
black
2002-1405
100
yellow
2002-1206
100
yellow
2002-1306
100
yellow
2002-1406
100
brown2002-1201/0000-0014
brown2002-1301/0000-0014
brown2002-1401/0000-0014
light gray2002-1209 100
light gray2002-1309 100
light gray2002-1409 100
2-conductor ground (earth) terminal block
3-conductor ground (earth) terminal block
4-conductor ground (earth) terminal block
2002-1207
100
green-yellow
2002-1307
100
green-yellow
2002-1407
100
green-yellow
2 Suitable for Ex e II applications 550 V, 22 A
2 Suitable for Ex e II applications 550 V, 22 A
2 Suitable for Ex e II applications 550 V, 22 A
Suitable for Ex i applications
Suitable for Ex i applications
Suitable for Ex i applications
4
4
4
4
4
4
Item Specific Accessories
Item Specific Accessories
Item Specific Accessories
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1292100 (4 x 25)
gray
2002-1291100 (4 x 25)
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1392100 (4 x 25)
gray
2002-1391100 (4 x 25)
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-1492100 (4 x 25)
gray
2002-1491100 (4 x 25)
Oversized endplates and sperator plates on page 92
2002 Series Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Push-in type jumper bar, insulated,
IN 25 A
light gray
2-way 2002-402200 (8 x 25)
3-way 2002-403200 (8 x 25)
4-way 2002-404200 (8 x 25)
5-way 2002-405100 (4 x 25)
6-way 2002-406100 (4 x 25)
7-way 2002-407100 (4 x 25)
8-way 2002-408100 (4 x 25)
9-way 2002-409100 (4 x 25)
10-way 2002-410100 (4 x 25)
Push-in type jumper bar, insulated,
IN 25 A
light gray
from 1-3 2002-433200 (8 x 25)
from 1-4 2002-434200 (8 x 25)
from 1-5 2002-435100 (4 x 25)
from 1-6 2002-436100 (4 x 25)
from 1-7 2002-437100 (4 x 25)
from 1-8 2002-438100 (4 x 25)
from 1-9 2002-439100 (4 x 25)
from 1-10 2002-440100 (4 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow
2002-115 100 (4 x 25)
Slim style jumper, insulated,
IN 25 A
light gray
2-way 2002-472 200 (8 x 25)
3-way 2002-473 200 (8 x 25)
4-way 2002-474 200 (8 x 25)
5-way 2002-475 100 (4 x 25)
:
12-way 2002-482 100 (4 x 25)
Step-down jumper, insulated,
IN 32 A
light gray 2006-499 50 (2 x 25)
Adjacent jumper for continuous commoning, insulate
1N 25 A
light gray
2-way
2002-400100 (4 x 25)
Insulation stop,
5 pcs/strip,
0.25 - 0.5 mm2
light gray 2002-171200 (8 x 25)
0.75 - 1 mm2
dark gray 2002-172200 (8 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap, for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
Modular TOPJOB®S connector,
for jumper contact slot
gray
2002-511100 (4 x 25)
Spacer module,
gray
2002-549100 (4 x 25)
End plate,
for modular TOPJOB®S connectors,
1.5 mm thick
gray
2002-541100 (4 x 25)
23
?
Rail-Mounted Terminal Blocks 4 (6) mm2/AWG 10
2004 Series
2
AWG 20 – 10
0.5 – 4 (6) mm 800 V/8 kV/3 600 V, 30 A U
32 A
600 V, 30 A 2
Terminal block width 6.2 mm / 0.244 in
L 11 – 13 mm / 0.47 in
0.5 – 4 (6) mm2 AWG 20 – 10
800 V/8 kV/3 600 V, 30 A U
32 A
600 V, 30 A 2
Terminal block width 6.2 mm / 0.244 in
L 11 – 13 mm / 0.47 in
0.5 – 4 (6) mm2 AWG 20 – 10
800 V/8 kV/3 600 V, 30 A U
32 A
600 V, 30 A 2
Terminal block width 6.2 mm / 0.244 in
L 11 – 13 mm / 0.47 in
ItemPack.-unit
No.pcs
<________ 65.5 mm /2.58 in ________>
4
4
4
4
4
4
ItemPack.-unit
No.pcs
4
4
4
4
4
4
2-conductor through terminal blocks
2004-1201 50
gray
blue
2004-1204 50
2
2004-1202 50
orange
red
2004-1203 50
black
2004-1205 50
yellow
2004-1206 50
3-conductor through terminal blocks
2004-1301 50
gray
blue
2004-1304 50
2
2004-1302 50
orange
red
2004-1303 50
black
2004-1305 50
yellow
2004-1306 50
4
4
<_12 _>
mm /
<___ 33
1.3 in ___>
4
<____ 52.5 mm /2.07 in ____>
mm /
<___ 33
1.3 in ___>
4
mm /
<___ 33
1.3 in ___>
2004 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 6mm2 (10 AWG) solid or stranded wire;
or direct insertion of: 1mm2 (18 AWG) - 6mm2 (10 AWG) solid or 0.75mm2 (18 AWG) - 4mm2 (12 AWG) stranded wire with ferrule (12mm barrel length)
4
<_____________ 79 mm /3.11 in _____________>
ItemPack.-unit
No.pcs
4
4
4
4
4
4
4-conductor through terminal blocks
2004-1401 50
gray
blue
2004-1404 50
2
2004-1402 50
orange
red
2004-1403 50
black
2004-1405 50
yellow
2004-1406 50
2-conductor ground (earth) terminal block
2004-1207 50
green-yellow
Suitable for Ex e II applications 550 V, 30 A
3-conductor ground (earth) terminal block
2004-1307 50
green-yellow
Suitable for Ex e II applications 550 V, 30 A
4-conductor ground (earth) terminal block
2004-1407 50
green-yellow Suitable for Ex e II applications 550 V, 30 A
2 Suitable for Ex i applications
2 Suitable for Ex i applications
2 Suitable for Ex i applications
4
4
4
Item Specific Accessories
Item Specific Accessories
Item Specific Accessories
End and intermediate plate, 1 mm thick
orange 2004-1292100 (4 x 25)
gray
2004-1291100 (4 x 25)
End and intermediate plate, 1 mm thick
orange 2004-1392100 (4 x 25)
gray
2004-1391100 (4 x 25)
End and intermediate plate, 1 mm thick
orange 2004-1492100 (4 x 25)
gray
2004-1491100 (4 x 25)
Oversized endplates and sperator plates on page 92
2004 Series Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Push-in type jumper bar, insulated,
IN 32 A
light gray
2-way 2004-402200 (8 x 25)
3-way 2004-403200 (8 x 25)
4-way 2004-404200 (8 x 25)
5-way 2004-405100 (4 x 25)
6-way 2004-406100 (4 x 25)
7-way 2004-407100 (4 x 25)
8-way 2004-408100 (4 x 25)
9-way 2004-409100 (4 x 25)
10-way 2004-410100 (4 x 25)
Push-in type jumper bar, insulated,
IN 32 A
light gray
from 1-3 2004-433200 (8 x 25)
from 1-4 2004-434200 (8 x 25)
from 1-5 2004-435100 (4 x 25)
from 1-6 2004-436100 (4 x 25)
from 1-7 2004-437100 (4 x 25)
from 1-8 2004-438100 (4 x 25)
from 1-9 2004-439100 (4 x 25)
from 1-10 2004-440100 (4 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow
2004-115 100 (4 x 25)
Delta jumper, insulated,
IN = IN terminal block, light gray
1-2 3-4 5-6 2004-406/020-000
100 (4 x 25)
Star point jumper, insulated,
IN = IN terminal block, light gray
1-3-52004-405/011-000
100 (4 x 25)
Step-down jumper, insulated,
IN 32 A
light gray 2006-499 50 (2 x 25)
Insulation stop,
5 pcs/strip,
0.25 - 0.5 mm2
light gray 2002-171200 (8 x 25)
0.75 - 1 mm2
dark gray 2002-172200 (8 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
24
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
Modular TOPJOB®S connector,
for jumper contact slot
gray
2004-511100 (4 x 25)
Spacer module,
gray
2004-549100 (4 x 25)
?
Rail-Mounted Terminal Blocks 6 (10) mm2/AWG 8
2006 Series
0.5 – 6 (10) mm2 AWG 20 – 8
800 V/8 kV/3 600 V, 50 A U
41 A
600 V, 50 A 2
Terminal block width 7.5 mm / 0.295 in
L 13 – 15 mm / 0.55 in
2
AWG 20 – 8
0.5 – 6 (10) mm 800 V/8 kV/3 600 V, 50 A U
41 A
600 V, 50 A 2
Terminal block width 7.5 mm / 0.295 in
L 13 – 15 mm / 0.55 in
Commoning with step-down jumpers
Application notes see page 7
<_____ 57.5 mm /2.26 in ______>
ItemPack.-unit
No.pcs
2-conductor through terminal blocks
2006-1201 50
gray blue 2006-1204 50
2006-1202 50
orange 4
4
4
4
2-conductor ground (earth) terminal block
2006-1207 50
green-yellow
Suitable for Ex e II applications 550 V, 38 A
Suitable for Ex i applications
4
Item Specific Accessories
End and intermediate plate, 1 mm thick
orange 2006-1292100 (4 x 25)
gray
2006-1291100 (4 x 25)
4
<____________ 73.5 mm /2.89 in ___________>
ItemPack.-unit
No.pcs
3-conductor through terminal blocks
2006-1301 25
gray blue 2006-1304 25
2006-1302 25
orange 4
4
4
4
3-conductor ground (earth) terminal block
2006-1307 25
green-yellow
Suitable for Ex e II applications 550 V, 36 A
Suitable for Ex i applications
4
<_12 _>
mm /
<___ 33
1.3 in ___>
4
mm /
<___ 33
1.3 in ___>
2006 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 10mm2 (8 AWG) solid or stranded wire;
or direct insertion of: 1mm2 (18 AWG) - 10mm2 (8 AWG) solid or 1.5mm2 (16 AWG) - 6mm2 (10 AWG) stranded wire with ferrule (14mm barrel length)
ItemPack.-unit
No.pcs
Commoning with step-down jumpers
An end plate must always be used between the terminal
blocks that are commoned with step-down jumpers.
Step-down jumper 2006-499 is suitable for commoning series
2006 or 2004 terminal blocks with series 2002, 2001 or
2000 terminal blocks.
Step-down jumpers are simply pushed down to full insertion, in
the same way as all other push-in type jumper bars.
Item Specific Accessories
End and intermediate plate, 1 mm thick
orange 2006-1392100 (4 x 25)
gray
2006-1391100 (4 x 25)
Step-down jumper, light gray, insulated
32 A
2006-499
50 (2 x 25)
Oversized endplates and sperator plates on page 92
2006 Series Accessories
Push-in type jumper bar, insulated,
IN 41 A
light gray
2-way 2006-402 50 (2 x 25)
3-way 2006-403 50 (2 x 25)
4-way 2006-404 50 (2 x 25)
5-way 2006-405 50 (2 x 25)
Push-in type jumper bar, insulated,
IN 41 A
light gray
from 1-3 2006-433 50 (2 x 25)
from 1-4 2006-434 50 (2 x 25)
from 1-5 2006-435 50 (2 x 25)
Star point jumper, insulated,
IN = IN terminal block, light gray
1-3-52006-405/011-000
50 (2 x 25)
Step-down jumper, insulated,
IN 32 A
light gray 2006-499 50 (2 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow 2006 -115 100 (4 x 25)
Appropriate marking systems:
WMB/Marking Strips (see pages 96 -101)
Lockout cap,
for conductor entry hole and
operating slot
gray 2006-19125
®
Modular TOPJOB S connector,
can be snapped together,
for jumper contact slot
gray
2006-511 100 (4 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
Note:
The total current flowing cannot exceed the
rating of the step-down jumper/push-in type
jumper bar.
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
25
?
Rail-Mounted Terminal Blocks 10 (16) mm2/AWG 6
2010 Series
2
AWG 20 – 6
0.5 – 10 (16) mm 800 V/8 kV/3 600 V, 65 A U
57 A
600 V, 65 A 2
Terminal block width 10 mm / 0.394 in
L 17 – 19 mm / 0.71 in
2
AWG 20 – 6
0.5 – 10 (16) mm 800 V/8 kV/3 600 V, 65 A U
57 A
600 V, 65 A 2
Terminal block width 10 mm / 0.394 in
L 17 – 19 mm / 0.71 in
Commoning with step-down jumpers
Application notes see page 7
<________ 68 mm /2.68 in _________>
ItemPack.-unit
No.pcs
4
4
4
2-conductor through terminal blocks
2010-1201 25
gray
blue
2010-1204 25
2010-1202 25
orange
4
2-conductor ground (earth) terminal block
2010-1207 25
green-yellow
Suitable for Ex e II applications 550 V, 51 A
4
Suitable for Ex i applications
4
<________ 89 mm /3.5 in _________>
ItemPack.-unit
No.pcs
4
4
4
3-conductor through terminal blocks
gray
2010-1301 25
blue
2010-1304 25
orange
2010-1302 25
4
3-conductor ground (earth) terminal block
green-yellow
2010-1307 25
Suitable for Ex e II applications 550 V, 50 A
4
Suitable for Ex i applications
Item Specific Accessories
Item Specific Accessories
End and intermediate plate, 1 mm thick
orange 2010-1292100 (4 x 25)
gray
2010-1291100 (4 x 25)
End and intermediate plate, 1 mm thick
orange 2010-1392100 (4 x 25)
gray
2010-1391100 (4 x 25)
Oversized endplates and sperator plates on page 92
2010 Series Accessories
Push-in type jumper bar, insulated,
IN 57 A
light gray
2-way 2010-402 50 (2 x 25)
3-way 2010-403 50 (2 x 25)
4-way 2010-404 50 (2 x 25)
5-way 2010-405 50 (2 x 25)
Push-in type jumper bar, insulated,
IN 57 A
light gray
from 1-3 2010-433 50 (2 x 25)
from 1-4 2010-434 50 (2 x 25)
from 1-5 2010-435 50 (2 x 25)
Star point jumper, insulated,
IN = IN terminal block, light gray
1-3-52010-405/011-000
50 (2 x 25)
Step-down jumper, insulated,
IN 57 A
light gray 2016-499 50 (2 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow
2010 -115 50 (8 x 25)
26
<_18 _>
/
<___ 37‑mm
1.46 in ___>
4
/
<___ 37‑mm
1.46 in ___>
2010 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 16mm2 (6 AWG) solid or stranded wire;
or direct insertion of: 2.5mm2 (14 AWG) - 16mm2 (6 AWG) solid or 2.5mm2 (14 AWG) - 10mm2 (8 AWG) stranded wire with ferrule (18mm barrel length)
Appropriate marking systems:
WMB/Marking Strips (see pages 96 -101)
Finger guard,
touchproof cover protects unused
conductor entries
yellow 2010-100 100 (4 x 25)
Modular TOPJOB®S connector,
can be snapped together,
for jumper contact slot
gray
2010-511 50 (2 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
ItemPack.-unit
No.pcs
Commoning with step-down jumpers
An end plate must always be used between the terminal
blocks that are commoned with step-down jumpers.
Step-down jumper 2016-499 is suitable for commoning series
2016 or 2010 terminal blocks with series 2010, 2006,
2004 or 2002 terminal blocks.
Step-down jumpers are simply pushed down to full insertion, in
the same way as all other push-in type jumper bars.
Step-down jumper, light gray, insulated
57 A
2016-499
50 (2 x 25)
Note:
The total current flowing cannot exceed the
rating of the step-down jumper/push-in type
jumper bar.
Finger guard cover snapped into unused clamping unit
(Example: Series 2016)
?
Rail-Mounted Terminal Blocks 16 (25 ”f-st”) mm2/AWG 4
2016 Series
2
0.5 – 16 (25 „f“) mm AWG 20 – 4
800 V/8 kV/3 600 V, 85 A U
76 A
600 V, 85 A 2
Terminal block width 12 mm / 0.472 in
L 18 – 20 mm / 0.75 in
2
0.5 – 16 (25 „f“) mm AWG 20 – 4
800 V/8 kV/3 600 V, 85 A U
76 A
600 V, 85 A 2
Terminal block width 12 mm / 0.472 in
L 18 – 20 mm / 0.75 in
Commoning with step-down jumpers
Application notes see page 7
<__­­_________ 70 mm /2.76 in _________>
ItemPack.-unit
No.pcs
2-conductor through terminal blocks
2016-1201 20
gray
blue
2016-1204 20
orange
2016-1202 20
4
4
4
4
2-conductor ground (earth) terminal block
2016-1207 20
green-yellow
Suitable for Ex e II applications 550 V, 70 A
Suitable for Ex i applications
4
<_18 _>
/
<___ 37‑mm
1.46 in ___>
4
/
<___ 37‑mm
1.46 in ___>
2016 Series terminal blocks can accomodate: 0.5mm2 (20 AWG) - 25mm2 (4 AWG) solid or stranded wire;
or direct insertion of: 2.5mm2 (14 AWG) - 16mm2 (6 AWG) solid or 2.5mm2 (14 AWG) - 16mm2 (6 AWG) stranded wire with ferrule (18mm barrel length)
4
<__­­_________ 92 mm /3.62 in _________>
ItemPack.-unit
No.pcs
3-conductor through terminal blocks
gray
2016-1301 20
blue
2016-1304 20
orange
2016-1302 20
4
4
4
4
3-conductor ground (earth) terminal block
green-yellow
2016-1307 20
Suitable for Ex e II applications 550 V, 67 A
Suitable for Ex i applications
4
Item Specific Accessories
Item Specific Accessories
End and intermediate plate, 1 mm thick
orange 2016-1292100 (4 x 25)
gray
2016-1291100 (4 x 25)
End and intermediate plate, 1 mm thick
orange 2016-1392100 (4 x 25)
gray
2016-1391100 (4 x 25)
ItemPack.-unit
No.pcs
Commoning with step-down jumpers
An end plate must always be used between the terminal
blocks that are commoned with step-down jumpers.
Step-down jumper 2016-499 is suitable for commoning series
2016 or 2010 terminal blocks with series 2010, 2006,
2004 or 2002 terminal blocks.
Step-down jumpers are simply pushed down to full insertion,
in the same way as all other push-in type jumper bars.
Step-down jumper, light gray, insulated
57 A
2016-499
50 (2 x 25)
Oversized endplates and sperator plates on page 92
2016 Series Accessories
Push-in type jumper bar, insulated,
IN 76 A
light gray
2-way 2016-402 50 (2 x 25)
3-way 2016-403 50 (2 x 25)
4-way 2016-404 50 (2 x 25)
5-way 2016-405 50 (2 x 25)
Push-in type jumper bar, insulated,
IN 57 A
light gray
from 1-3 2016-433 50 (2 x 25)
from 1-4 2016-434 50 (2 x 25)
from 1-5 2016-435 50 (2 x 25)
Star point jumper, insulated,
IN = IN terminal block, light gray
1-3-52016-405/011-000
50 (2 x 25)
Step-down jumper, insulated,
IN 57 A
light gray 2016-499 50 (2 x 25)
Protective warning marker,
with high voltage symbol, black,
for 5 terminal blocks
yellow
2016 -115 50 (8 x 25)
Appropriate marking systems:
WMB/Marking Strips (see pages 96 -101)
Finger guard,
touchproof cover protects unused
conductor entries
yellow 2016-100 100 (4 x 25)
Modular TOPJOB®S connector,
can be snapped together,
for jumper contact slot
gray
2016-511 50 (2 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
Marking strip, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
Note:
The total current flowing cannot exceed the
rating of the step-down jumper/push-in type
jumper bar.
Commoning from 35mm2/2 AWG POWER CAGE
CLAMP® terminal blocks to 10/16mm2 (8/10 AWG)
TOPJOB®S terminal blocks is available with 285-430
step-down jumper.
27
?
3- and 4-Conductor Rail-Mounted Terminal Blocks 2.5 (4) mm2/AWG 12
2002Series
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3 600 V, 20 A U
24 A
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
2
AWG 22 – 12
0.25 – 2.5 (4) mm 800 V/8 kV/3 600 V, 20 A U
24 A
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<_____ 52 mm /2.05 in _____>
4
4
4
4
4
4
3-conductor through terminal blocks
gray
2002-6301
blue
2002-6304
2002-6302
orange
red
2002-6303 2002-6305 black
2002-6306 yellow
3-conductor ground (earth) terminal block
2002-6307
green-yellow
Suitable for Ex i applications
4
<_____ 52 mm /2.05 in _____>
ItemPack.-unit
No.pcs
100
100
100
100
100
100
100
Accessories
4
4
4
4
4
4
ItemPack.-unit
No.pcs
4-conductor through terminal blocks
gray
2002-6401
blue
2002-6404
2002-6402
orange
red
2002-6403 2002-6405 black
2002-6406 yellow
4-conductor ground (earth) terminal block
2002-6407
green-yellow
Suitable for Ex i applications
4
100
100
100
100
100
100
100
Attention! These terminal blocks cannot be commoned!
Appropriate marking systems:
WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 0.8 mm /0.031 in thick
End and intermediate plate, 0.8 mm /0.031 in thick
orange 2002-6392100 (4 x 25) orange 2002-6392100 (4 x 25)
gray
2002-6391100 (4 x 25) gray
2002-6391100 (4 x 25)
Oversized endplates and separator plates on page 92
Insulation stop, 5 pcs/strip
200 strips
Push-in type jumper bars, light gray, insulated, IN 25 A
2-way 2002-402200 (8 x 25)
3-way 2002-403200 (8 x 25)
light gray2002-171 0.25-0.5 mm2
dark gray2002-172 0.75-1 mm2
4-way 2002-404200 (8 x 25)
5-way 2002-405100 (4 x 25) Protective warning marker,
: :
for 5 terminal blocks
yellow 2002-115100 (4 x 25)
10-way 2002-410100 (4 x 25)
Marking strip, plain,
11 mm wide
Push-in type jumper bars, light gray, insulated, IN 25 A
50 m roll
white
2009-110
1
1 - 3 2002-433200 (8 x 25)
WMB Multi marking system,
1 - 4 2002-434200 (8 x 25)
10 strips with 10 markers per card,
1 - 5 2002-435100 (4 x 25)
stretchable 5 - 5.2 mm
: :
plain
793-5501
5
1 - 10 2002-440100 (4 x 25)
®
Modular TOPJOB S connector**,
WMB Inline, plain,
for jumper contact slot
stretchable 5 - 5.2mm,
1 pole 2002-511100 (4 x 25)
1,500 WMB markers, 5mm, on roll
white
2009-115 1
Spacer, modular
2002-549100 (4 x 25)
Test plug adapter,
for test plug 4 mm Ø
2009-174 100 (4 x 25)
gray
Testing tap,
for max. 2.5 mm2
gray
2009-182 100 (4 x 25)
28
<_12 _>
/
<____ 39‑mm
1.54 in _____>
/
<____ 39‑mm
1.54 in _____>
2002 Series terminal blocks can accomodate: 0.25mm2 (22 AWG) - 4mm2 (12 AWG) solid or stranded wire;
or direct insertion of: 0.75mm2 (18 AWG) - 4mm2 (12 AWG) solid or 0.75mm2 (18 AWG) - 2.5mm2 (14 AWG) stranded wire with ferrule (12mm barrel length)
3- and 4-conductor terminal blocks
The TOPJOB®S rail-mounted terminal blocks
have a conductor entry angle of 35 degrees
allowing for a very small bend radius and an
extremely short wiring distance to the cable
duct. For applications in switchgear and control cabinets using the LSC wiring system from
Lütze, for example, the new terminal blocks
offer a space and cost saving solution. This
way, conductors can be placed very close to
the terminal blocks and their height can be
kept relatively low.
Product features
®
• CAGE CLAMP S connection for all types
of conductors, with the additional benefit
that stripped solid wires and fine-stranded
ferruled wires can be simply pushed in
ibration-proof, fast, maintenance-free con•V
nection
• 3-conductor through and ground (earth)
conductor terminal blocks equipped with
dual jumper slot
• 4-conductor terminal blocks allow for the
multiplication of potentials without using
any jumpers and any additional terminal
blocks
• 3- and 4-conductor terminal blocks have
the same dimensions
Push-In Type
Wire Jumpers
Test Plug Adapter
and Testing Tap
Test plug adapter and testing tap
for testing rail-mounted terminal blocks
of Series
2001/2002/2004/2006/2010/2016
Motor Configuration
Jumpers
Push-in type wire jumper
Nominal voltage: 800 V/8 kV/3
Nominal current: 16 A
Rated cross section: 1.5 mm2
Wire lengths:
60/110/250 mm
Motor Configuration Jumpers
Nominal voltage: 800 V/8 kV/3
Nominal current: In = In terminal block
of relevant series
Push-in type jumper bar
2002-405/011-000
2002-406/020-000
Item
Pack. unit
No.pcs
Test plug adapter,
for test plugs 4 mm/0.157 in Ø,
for testing rail-mounted terminal blocks
of Series
2001/2002/2004/2006/2010/2016
2009-174
100 (4 x 25)
Testing tap,
for connecting individual test wires of AWG 28 to 14
(0.08 mm2 – 2.5 mm2) without tools
2009-182
100 (4 x 25)
Testing TOPJOB®S rail-mounted terminal blocks
using a test plug adapter or testing tap
ItemPack.-unit
No.pcs
ItemPack.-unit
No.pcs
Push-in type wire jumpers,
insulated, conductor cross section 1.5 mm2,
suitable for rail-mounted terminal blocks of Series 2001,
2002 and 2022
Wye configuration jumpers,
light gray, insulated​
Suitable for Series:​
2000
2000-405/011-000
2001
2001-405/011-000
2002
2002-405/011-000
2004
2004-405/011-000
2006
2006-405/011-000
2010
2010-405/011-000
2016
2016-405/011-000
Wire length
60 mm2009-412 100
110 mm2009-414 100
250 mm2009-416 100
Push down the wire jumper until fully inserted.
Lift the jumper with a screwdriver for rewiring.
Push-in type wire jumpers, insulated cross section,
0.75 mm2, suitable for rail-mounted terminal blocks of
series 2000 and 2020.
Wire length
60 mm
110 mm
250 mm
2009-402
2009-404
2009-406
This jumper has been specially developed to create
awye configuration and is used on motor terminal
boardsequipped with TOPJOB®S rail-mounted terminal blocks​
Delta jumpers,
light gray, insulated​
Suitable for Series:​
2000
2000-406/020-000
2001
2001-406/020-000
2002
2002-406/020-000
2004
2004-406/020-000
100
100
100
Lockout cap, for conductor entry hole and operating slot
gray
gray
2002-191
2006-191
25
25
This jumper has been specially developed to create
a "delta" configuration and is used on motor terminal boards equipped with TOPJOB®S rail-mounted
terminal blocks
Lockout cap for covering unused clamping units
of the 2002 or 2006 Series terminal blocks.
29
?
Adjacent Jumpers for Continuous Commoning, Vertical Jumpers,
Adjacent Colored Push-In Jumper Bars
Adjacent jumper for continuous commoning
Slim style jumper bar
Push-in type jumper bars
Vertical jumpers
ItemPack.-unit
No.pcs
Adjacent jumper for continuous commoning,
insulated,
IN 25 A
2-way
2002-400
100 (4x25)
Double-deck vertical jumper, insulated,
IN 24 A
light gray
2002-492
50 (2 x 25)
Triple-deck vertical jumper, insulated,
IN 24 A
light gray
2002-493
50 (2 x 25)
Double-deck vertical jumper, insulated,
IN 13.5 A
light gray
2000-492
50 (2 x 25)
Vertical jumper
30
ItemPack.-unit
No.pcs
Push-in slim style jumper bar, insulated,
IN 25 A
2-way
2002-472
3-way
2002-473
4-way
2002-474
5-way
2002-475
:
:
12-way
2002-482
Slim style jumper
100 (4x25)
100 (4x25)
100 (4x25)
50 (2x25)
50 (2x25)
ItemPack.-unit
No.pcs
Push-in type jumper bar, insulated,
IN 25 A
blue
2-way
2002-402/000-006
3-way
2002-403/000-006
4-way
2002-404/000-006
5-way
2002-405/000-006
6-way
2002-406/000-006
7-way
2002-407/000-006
8-way
2002-408/000-006
9-way
2002-409/000-006
10-way
2002-410/000-006
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
Push-in type jumper bar, insulated,
IN 25 A
red
2-way
2002-402/000-005
3-way
2002-403/000-005
4-way
2002-404/000-005
5-way
2002-405/000-005
6-way
2002-406/000-005
7-way
2002-407/000-005
8-way
2002-408/000-005
9-way
2002-409/000-005
10-way
2002-410/000-005
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
Colored push-in type jumper bars are used with sensor
terminal blocks
?
Connector Strips with CAGE CLAMP ®S Connection
2001 Series
2002 Series
2004 Series
0.25 – 1.5 (2.5) mm2 AWG 22 – 14
500 V/6 kV/3 300 V, 15 A U
18 A
300 V, 15 A 2
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
0.25 – 2.5 (4) mm2
AWG 22 – 12
500 V/6 kV/3 300 V, 20 A U
24 A
300 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
0.5 – 4 (6) mm2
AWG 20 – 10
500 V/6 kV/3 300 V, 30 A U
32 A
300 V, 30 A 2
Terminal block width 6.2 mm / 0.244 in
L 11 – 13 mm / 0.47 in
Item
No.
Item
No.
Item
No.
Pack.-unit
pcs
Pack.-unit
pcs
Pack.-unit
pcs
Modular TOPJOB®S connector strips
with CAGE CLAMP ®S connection, modular, gray,
2-pole
2001-552
3-pole
2001-553
4-pole
2001-554
5-pole
2001-555
6-pole
2001-556
7-pole
2001-557
8-pole
2001-558
9-pole
2001-559
10-pole
2001-560
Modular TOPJOB®S connector strips
with CAGE CLAMP ®S connection, modular, gray,
2-pole
2002-552
3-pole
2002-553
4-pole
2002-554
5-pole
2002-555
6-pole
2002-556
7-pole
2002-557
8-pole
2002-558
9-pole
2002-559
10-pole
2002-560
Modular TOPJOB®S connector strips
with CAGE CLAMP ®S connection, modular, gray,
2-pole
2004-552
2004-553
3-pole
2004-554
4-pole
2004-555
5-pole
Item-specific accessories
Item-specific accessories
Item-specific accessories
WMB Multi marking card, 10 strips with 10 markers each, white with black printing,
4 – 4.2 mm/0.157 - 0.165 in wide
5 cards
793-4 . . .
794-4 . . .
5 cards
see pages 90-92
WMB Multi marking card, 10 strips with 10 markers each, white with black printing,
5 – 5.2 mm/0.197 - 0.205 in wide
5 cards
793-5 . . .
794-5 . . .
5 cards
see pages 90-92
The modular connectors provide an additional
connection option for conductors of the same cross
section range as the terminal blocks being used.
WMB Multi marking card, 10 strips with 10 markers each, white with black printing,
5 – 5.2 mm/0.197 - 0.205 in wide
5 cards
793-5 . . .
794-5 . . .
5 cards
see pages 90-92
The connector has a test socket for 2 mm/0.079 in
or 2.3 mm/0.091 in test plugs.
Accessories for TOPJOB®S connectors
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Test plug, with cable 500‑mm /1’7.7’’
2.3 mm/0.091 in Ø
yellow210-137
50 (5 x 10)
Test plug, with cable 500‑mm /1’7.7’’
2 mm/0.079 in Ø
red210-136
50 (5 x 10)
Strain relief plate, gray
snappable onto connector strips
6 mm /0.236 in wide
12.5 mm /0.492 in wide
25 mm /0.984 in wide
35 mm /1.378 in wide
734-327
734-328
734-329
734-326
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
Marker strips, plain, on roll
11 mm /0.039 in wide
50 m
2009-110
1
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
31
?
Modular Connectors with CAGE CLAMP ®S Connection
2001 Series
2002 Series
2004 Series
0.25 – 1.5 (2.5) mm2 AWG 22 – 14
500 V/6 kV/3 300 V, 15 A U 18 A
300 V, 15 A 2
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
Item
No.
Pack.-unit
pcs
0.5 – 4 (6) mm2
AWG 20 – 10
500 V/6 kV/3 300 V, 30 A U
32 A
300 V, 30 A 2
Terminal block width 6.2 mm / 0.244 in
L 11 – 13 mm / 0.47 in
Item
No.
Item
No.
Pack.-unit
pcs
Pack.-unit
pcs
Modular TOPJOB S connectors
with CAGE CLAMP ®S connection, modular, gray,
1 pole
2001-511
100 (4 x 25)
Modular TOPJOB S connectors
with CAGE CLAMP ®S connection, modular, gray,
1 pole
2002-511
100 (4 x 25)
Modular TOPJOB S connectors
with CAGE CLAMP ®S connection, modular, gray,
1 pole
2004-511
100 (4 x 25)
Spacer, for bridging over commoned terminal blocks, for
example, modular, gray
2001-549 100 (4 x 25)
Spacer, for bridging over commoned terminal blocks, for
example, modular, gray
2002-549 100 (4 x 25)
Spacer, for bridging over commoned terminal blocks, for
example, modular, gray
2004-549 100 (4 x 25)
®
®
®
Item-specific accessories
Item-specific accessories
Item-specific accessories
End plate, 1.5 mm/0.059 in thick
gray
2002-541 100 (4 x 25)
End plate, 1.5 mm/0.059 in thick
gray
2002-541 100 (4 x 25)
End plate, 1.5 mm/0.059 in thick
gray
2004-541 100 (4 x 25)
WMB Multi marking card, 10 strips with 10 markers each, white with black printing,
4 – 4.2 mm/0.157 - 0.165 in wide
5 cards
793-4 . . .
794-4 . . .
5 cards
see pages 90-92
WMB Multi marking card, 10 strips with 10 markers each, white with black printing,
5 – 5.2 mm/0.197 - 0.205 in wide
5 cards
793-5 . . .
794-5 . . .
5 cards
see pages 90-92
WMB Multi marking card, 10 strips with 10 markers each, white with black printing,
5 – 5.2 mm/0.197 - 0.205 in wide
5 cards
793-5 . . .
794-5 . . .
5 cards
see pages 90-92
Snapping together of connectors and spacers to assemble
a multi-pole connector
32
2
AWG 22 – 12
0.25 – 2.5 (4) mm 500 V/6 kV/3 300 V, 20 A U
24 A
300 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Wire connection:
Screwdriver actuation for connection of all conductor
types, i.e. stripped stranded conductors, or push-in connection of solid or ferruled stranded conductors.
Snapping on a strain relief plate
Accessories for TOPJOB®S connectors
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Test plug, with cable 500‑mm /1’7.7’’
2.3 mm/0.091 in Ø
yellow210-137
50 (5 x 10)
Test plug, with cable 500‑mm /1’7.7’’
2 mm/0.079 in Ø
red210-136
50 (5 x 10)
Strain relief plate, gray
snappable onto connector strips
6 mm /0.236 in wide
12.5 mm /0.492 in wide
25 mm /0.984 in wide
35 mm /1.378 in wide
734-327
734-328
734-329
734-326
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
Marker strips, withe, plain, on roll
11 mm /0.039 in wide
50 m
2009-110
1
WMB Inline, plain,
stretchable 5 - 5.2mm,
1,500 WMB markers, 5mm, on roll
white
2009-115 1
?
Modular Connectors with CAGE CLAMP®S Connection,
2006 Series
2010 Series
2016 Series
0.5 – 4 (6) mm2 AWG 20 – 10
500 V/6 kV/3 IN 32 A
Terminal block width 7.5 mm / 0.295 in
L 11 – 13 mm / 0.47 in
2
AWG 20 – 10
0.5 – 4 (6) mm 500 V/6 kV/3 IN 32 A
Terminal block width 10 mm / 0.394 in
L 11 – 13 mm / 0.47 in
2
AWG 20 – 10
0.5 – 4 (6) mm 500 V/6 kV/3 IN 32 A
Terminal block width 12 mm / 0.472 in
L 11 – 13 mm / 0.47 in
ItemPack.-unit
No.pcs
ItemPack.-unit
No.pcs
®
TOPJOB S connector,
for jumper contact slot,
modular, gray
2006-511
50 (2x25)
1-pole
ItemPack.-unit
No.pcs
®
TOPJOB S connector,
for jumper contact slot,
modular, gray
2010-511
50 (2x25)
1-pole
TOPJOB®S connector,
for jumper contact slot,
modular, gray
2016-511
1-pole
Spacer module, can be snapped together,
e.g., for bridging commoned terminal blocks
2006-549
50 (2x25)
gray
Spacer module, can be snapped together,
e.g., for bridging commoned terminal blocks
2010-549
50 (2x25)
gray
Spacer module, can be snapped together,
e.g., for bridging commoned terminal blocks
2016-549
50 (2x25)
gray
Accessories Connector Strips
End plate,
for modular TOPJOB®S connectors,
1.5 mm thick
gray
2004-541 100 (4 x 25)
Test plug,
500 mm /17.7 in cable
2.3 mm Ø
yellow 210-137 50
Test plug,
500 mm /17.7 in cable
2 mm Ø
red
210-136 50
50 (2x25)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Strain relief plate, gray
3.5 mm wide
6 mm wide
12.5 mm wide
25 mm wide
734-326
734-327
734-328
734-329
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
Marker strips, plain,
11 mm wide
50 m roll
white
2009-110
1
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
33
0.25 – 2.5 (4) mm2 AWG 22 – 12
300 V/6 kV/3 IN 18 A
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Simply push-in to conductor entry and pull out to remove
34
?
Double Deck Terminal Blocks 1 (1.5) mm2 /AWG 16
2000 Series
<_____ 69.7‑mm /2.74‑in _____>
<_____ 69.7‑mm /2.74‑in _____>
Pack.-unit
pcs
50
50
50
50
Through/through terminal block,
without marking carrier, housing color blue
N/N
2000-2204
50
Pack.-unit
pcs
50
50
50
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Through/through terminal block,
without marking carrier, housing color gray
2000-2201
L /L N/L 2000-2202
L/N
2000-2203
Item
No.
Through/through terminal block,
with marking carrier, housing color blue
N/N
2000-2234
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
L
2000-2238 50
<_____ 69.7‑mm /2.74‑in _____>
<_____ 69.7‑mm /2.74‑in _____>
Item
No.
Ground conductor/through terminal block,
with marking carrier, housing color gray
PE/N
2000-2247
PE/L
2000-2257
Pack.-unit
pcs
50
50
Ground conductor/through terminal block,
without marking carrier, housing color gray
PE/N
2000-2217
PE/L
2000-2227
50
50
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color blue
N
2000-2239 50
4-conductor through terminal block,
4-conductor through terminal block,
without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
position colored in violet, housing color blue
L
2000-2208
50
N
2000-2209
50
Accessories
Terminal block width 3.5 mm / 0.138 in
L 9 – 11 mm / 0.39 in
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Item
No.
Through/through terminal block,
with marking carrier, housing color gray
2000-2231
L /L N/L 2000-2232
L/N
2000-2233
AWG 24 – 16
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Terminal block width 3.5 mm / 0.138 in
L 9 – 11 mm / 0.39 in
4-Zulassungen in Vorbereitung
0.14 – 1 (1.5) mm2
500 V/6 kV/3
IN 13.5 A
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Terminal block width 3.5 mm / 0.138 in
L 9 – 11 mm / 0.39 in
4-Zulassungen in Vorbereitung
AWG 24 – 16
600 V, 10 A U
600 V, 10 A 2
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
0.14 – 1 (1.5) mm2
500 V/6 kV/3
IN 13.5 A
AWG 24 – 16
600 V, 10 A U
600 V, 10 A 2
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
0.14 – 1 (1.5) mm2
500 V/6 kV/3
IN 13.5 A
Item
No.
4-conductor ground terminal block,
with marking carrier, internal commoning
Housing color green-yellow
PE
2000-2237 4-conductor ground terminal block,
without marking carrier, internal commoning
Housing color green-yellow
PE
2000-2207
Pack.-unit
pcs
50
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 0.7 mm thick
orange 2000-2292 100 (4 x 25)
gray 2000-2291 100 (4 x 25)
Double-deck marker carrier,
pivotable, gray
2000-121
Push-in type jumper bars, light gray, insulated, IN 14 A
2-way 2000-402 200 (8 x 25)
3-way 2000-403 200 (8 x 25)
4-way 2000-404 200 (8 x 25)
5-way 2000-405 100 (4 x 25)
:
:
10-way 2000-410 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 14 A
1 - 3 2000-433 200 (8 x 25)
1 - 4 2000-434 200 (8 x 25)
1 - 5 2000-435 100 (4 x 25)
: :
1 - 10 2000-440 100 (4 x 25)
50 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks
yellow 2000-115 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 3.5 mm terminal block width
plain
793-3501 5
35
?
Double Deck Terminal Blocks 1 (1.5) mm2 with End Plate/AWG 16
2000 Series
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
Through/through terminal block, with end plate
with marking carrier, housing color gray
2000-2231/099-000
50
L /L N/L 2000-2232/099-000
50
L/N
2000-2233/099-000
50
Through/through terminal block, with end plate
with outmarking carrier, housing color blue
N/N
2000-2204/099-000
50
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Through/through terminal block, with end plate
without marking carrier, housing color gray
2000-2201/099-000
50
L /L N/L 2000-2202/099-000
50
L/N
2000-2203/099-000
50
Item
Pack.-unit
No.
pcs
Through/through terminal block, with end plate
with marking carrier, housing color blue
N/N
2000-2234/099-000
50
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block, with end plate
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
L
2000-2238/099-000
50
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block, with end plate
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color blue
N
2000-2239/099-000 50
36
Item
Pack.-unit
No.
pcs
Ground conductor/through terminal block, with end plate
with marking carrier, housing color gray
PE/N
2000-2247/099-000
50
PE/L
2000-2257/099-000
50
Ground conductor/through terminal block, with end plate
without marking carrier, housing color gray
PE/N
2000-2217/099-000
50
PE/L
2000-2227/099-000
50
Item
Pack.-unit
No.
pcs
4-conductor ground terminal block, with end plate
with marking carrier, internal commoning
Housing color green-yellow
PE
2000-2237/099-000 50
4-conductor ground terminal block, with end plate
without marking carrier, internal commoning
Housing color green-yellow
PE
2000-2207/099-000
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Double-deck marker carrier,
pivotable, gray
2000-121
Push-in type jumper bars, light gray, insulated, IN 18 A
2-way 2001-402 200 (8 x 25)
3-way 2001-403 200 (8 x 25)
4-way 2001-404 200 (8 x 25)
5-way 2001-405 100 (4 x 25)
:
:
10-way 2001-410 100 (4 x 25)
<_____ 69.7‑mm /2.74‑in _____>
<_____ 69.7‑mm /2.74‑in _____>
4-conductor through terminal block, with end plate
4-conductor through terminal block, with end plate
without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
position colored in violet, housing color blue
L
2000-2208/099-000
50
N
2000-2209/099-000
50
Accessories
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
<_____ 69.7‑mm /2.74‑in _____>
AWG 24 – 16
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
4-Zulassungen in Vorbereitung
0.14 – 1 (1.5) mm2
800 V/8 kV/3
IN 13.5 A (18 A)
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
4-Zulassungen in Vorbereitung
AWG 24 – 16
600 V, 10 A U
600 V, 10 A 2
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
0.14 – 1 (1.5) mm2
800 V/8 kV/3
IN 13.5 A (18 A)
AWG 24 – 16
600 V, 10 A U
600 V, 10 A 2
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
0.14 – 1 (1.5) mm2
800 V/8 kV/3
IN 13.5 A (18 A)
50 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 18 A
1 - 3 2001-433 200 (8 x 25)
1 - 4 2001-434 200 (8 x 25)
1 - 5 2001-435 100 (4 x 25)
: :
1 - 10 2001-440 100 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks
yellow 2000-115 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 4-4.2 mm terminal block width
plain
793-4501 5
?
Double Deck Terminal Blocks 2.5 (4) mm2/AWG 12
2002 Series
<_____ 70mm /2.76in _____>
Pack.-unit
pcs
50
50
50
50
Through/through terminal block,
with outmarking carrier, housing color blue
N/N 4
2002-2204
50
Pack.-unit
pcs
50
50
50
<_ 52 mm /2.04‑in _>
<___ 62 mm /2.44‑in ____>
Through/through terminal block,
without marking carrier, housing color gray
2002-2201
L /L 4
N/L 4
2002-2202
2002-2203
L/N 4
Item
No.
Through/through terminal block,
with marking carrier, housing color blue
N/N 4
2002-2234
<_____ 70mm /2.76in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
L 4
2002-2238 50
<_____ 70mm /2.76in _____>
<_ 52 mm /2.04‑in _>
<___ 62 mm /2.44‑in ____>
Item
No.
Ground conductor/through terminal block,
with marking carrier, housing color gray
PE/N 4
2002-2247
PE/L 4
2002-2257
Pack.-unit
pcs
50
50
Ground conductor/through terminal block,
without marking carrier, housing color gray
PE/N 4
2002-2217
PE/L 4
2002-2227
50
50
<_____ 70mm /2.76in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color blue
N 4
2002-2239 50
4-conductor through terminal block,
4-conductor through terminal block,
without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
position colored in violet, housing color blue
L 4
2002-2208
50
N 4
2002-2209
50
Accessories
<_____ 70mm /2.76in _____>
<_ 52 mm /2.04‑in _>
<___ 62 mm /2.44‑in ____>
Item
No.
Through/through terminal block,
with marking carrier, housing color gray
2002-2231
L /L 4
N/L 4
2002-2232
2002-2233
L/N 4
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
300 V, 20 A U IN 24 A
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
<_ 52 mm /2.04‑in _>
<___ 62 mm /2.44‑in ____>
<_____ 70mm /2.76in _____>
<_ 52 mm /2.04‑in _>
<___ 62 mm /2.44‑in ____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
300 V, 20 A U IN 24 A
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
<_ 52 mm /2.04‑in _>
<___ 62 mm /2.44‑in ____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
300 V, 20 A U IN 24 A
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
Item
No.
4-conductor ground terminal block,
with marking carrier, internal commoning
Housing color green-yellow
PE 4
2002-2237 4-conductor ground terminal block,
without marking carrier, internal commoning
Housing color green-yellow
PE 4
2002-2207
Pack.-unit
pcs
50
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 0.7 mm thick
orange 2002-2292 100 (4 x 25)
gray 2002-2291 100 (4 x 25)
Double-deck marker carrier,
pivotable, gray
2002-121
Push-in type jumper bars, light gray, insulated, IN 14 A
2-way 2002-402 200 (8 x 25)
3-way 2002-403 200 (8 x 25)
4-way 2002-404 200 (8 x 25)
5-way 2002-405 100 (4 x 25)
:
:
10-way 2002-410 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 14 A
1 - 3 2002-433 200 (8 x 25)
1 - 4 2002-434 200 (8 x 25)
1 - 5 2002-435 100 (4 x 25)
: :
1 - 10 2002-440 100 (4 x 25)
50 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks
yellow 2002-115 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 4-4.2 mm terminal block width
plain
793-5501 5
37
?
Double Deck Terminal Blocks 2.5 (4) mm2 with End Plate/AWG 12
2002 Series
Item
Pack.-unit
No.
pcs
Through/through terminal block, with end plate
with marking carrier, housing color gray
2002-2231/099-000
50
L /L N/L 2002-2232/099-000
50
L/N
2002-2233/099-000
50
Through/through terminal block, with end plate
without marking carrier, housing color blue
N/N
2002-2204/099-000
50
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Through/through terminal block, with end plate
without marking carrier, housing color gray
2002-2201/099-000
50
L /L N/L 2002-2202/099-000
50
L/N
2002-2203/099-000
50
Item
Pack.-unit
No.
pcs
Through/through terminal block, with end plate
with marking carrier, housing color blue
N/N
2002-2234/099-000
50
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block, with end plate
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
L
2002-2238/099-000
50
<_____ 69.7‑mm /2.74‑in _____>
Item
Pack.-unit
No.
pcs
4-conductor through terminal block, with end plate
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color blue
N
2002-2239/099-000 50
38
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
Ground conductor/through terminal block, with end plate
without marking carrier, housing color gray
PE/N
2002-2217/099-000
50
PE/L
2002-2227/099-000
50
Item
Pack.-unit
No.
pcs
4-conductor ground terminal block, with end plate
with marking carrier, internal commoning
Housing color green-yellow
PE
2002-2237/099-000 50
4-conductor ground terminal block, with end plate
without marking carrier, internal commoning
Housing color green-yellow
PE
2002-2207/099-000
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Double-deck marker carrier,
pivotable, gray
2002-121
Push-in type jumper bars, light gray, insulated, IN 32 A
2-way 2004-402 200 (8 x 25)
3-way 2004-403 200 (8 x 25)
4-way 2004-404 200 (8 x 25)
5-way 2004-405 100 (4 x 25)
:
:
10-way 2004-410 100 (4 x 25)
Item
Pack.-unit
No.
pcs
Ground conductor/through terminal block, with end plate
with marking carrier, housing color gray
PE/N
2002-2247/099-000
50
PE/L
2002-2257/099-000
50
<_____ 69.7‑mm /2.74‑in _____>
4-conductor through terminal block, with end plate
4-conductor through terminal block, with end plate
without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
position colored in violet, housing color blue
L
2002-2208/099-000
50
N
2002-2209/099-000
50
Accessories
<_____ 69.7‑mm /2.74‑in _____>
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
<_____ 69.7‑mm /2.74‑in _____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
IN 24 A
Terminal block width 6.2 / 0.244 in
L 10 – 12 mm / 0.43 in
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
<_____ 69.7‑mm /2.74‑in _____>
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
0.25 – 2.5 (4) mm2
AWG 22 – 12
800 V/8 kV/3
600 V, 20 A U
IN 24 A
600 V, 20 A 2
Terminal block width 6.2 / 0.244 in
L 10 – 12 mm / 0.43 in
<_ 51.7 mm /2.04‑in _>
<___ 61.8 mm /2.43‑in ____>
0.25 – 2.5 (4) mm2
AWG 22 – 12
800 V/8 kV/3
600 V, 20 A U
IN 24 A
600 V, 20 A 2
Terminal block width 6.2 / 0.244 in
L 10 – 12 mm / 0.43 in
50 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 32 A
1 - 3 2004-433 200 (8 x 25)
1 - 4 2004-434 200 (8 x 25)
1 - 5 2004-435 100 (4 x 25)
: :
1 - 10 2004-440 100 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks
yellow 2000-115 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 5-5.2 mm terminal block width
plain
793-5501 5
?
4-Conductor, Double Deck Terminal Blocks 2.5 (4) mm2/AWG 12
2002 Series
<_____ 105.5mm /4.15in _____>
50
50
50
Item
No.
Through/through terminal block,
with marking carrier, housing color blue
N/N 2002-2434
Pack.-unit
pcs
50
Through/through terminal block,
without marking carrier, housing color blue
N/N 2002-2404
50
50
50
50
<_ 52.5 mm /2.07in _>
<___ 63 mm /2.48in ____>
Through/through terminal block,
without marking carrier, housing color gray
2002-2401
L /L N/L 2002-2402
L/N 2002-2403
Pack.-unit
pcs
<_____ 105.5mm /4.15in _____>
Item
Pack.-unit
No.
pcs
8-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
L
2002-2438 50
<_____ 105.5mm /4.15in _____>
<_ 52.5 mm /2.07in _>
<___ 63 mm /2.48in ____>
Pack.-unit
pcs
50
50
Ground conductor/through terminal block,
without marking carrier, housing color gray
PE/N 2002-2417
PE/L 2002-2427
50
50
<_____ 105.5mm /4.15in _____>
Item
Pack.-unit
No.
pcs
8-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color blue
N
2002-2439 50
8-conductor through terminal block,
8-conductor through terminal block,
without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
position colored in violet, housing color blue
L
2002-2408
50
N
2002-2409
50
Accessories
Item
No.
Ground conductor/through terminal block,
with marking carrier, housing color gray
PE/N 2002-2447
PE/L 2002-2457
<_ 52.5 mm /2.07in _>
<___ 63 mm /2.48in ____>
Item
No.
Through/through terminal block,
with marking carrier, housing color gray
2002-2431
L /L N/L 2002-2432
L/N 2002-2433
<_____ 105.5mm /4.15in _____>
<_ 52.5 mm /2.07in _>
<___ 63 mm /2.48in ____>
<_____ 105.5mm /4.15in _____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
600 V, 20 A U IN 24 A (28 A)
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
<_ 52.5 mm /2.07in _>
<___ 63 mm /2.48in ____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
600 V, 20 A U IN 24 A (28 A)
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
<_ 52.5 mm /2.07in _>
<___ 63 mm /2.48in ____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
800 V/8 kV/3
600 V, 20 A U IN 24 A (28 A)
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
Item
No.
8-conductor ground terminal block,
with marking carrier, internal commoning
Housing color green-yellow
PE 2002-2437 8-conductor ground terminal block,
without marking carrier, internal commoning
Housing color green-yellow
PE 2002-2407
Pack.-unit
pcs
50
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 0.7 mm thick
orange 2002-2492 100 (4 x 25)
gray 2002-2491 100 (4 x 25)
Double-deck marker carrier,
pivotable, gray
2002-121
Push-in type jumper bars, light gray, insulated, IN 14 A
2-way 2002-402 200 (8 x 25)
3-way 2002-403 200 (8 x 25)
4-way 2002-404 200 (8 x 25)
5-way 2002-405 100 (4 x 25)
:
:
10-way 2002-410 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 14 A
1 - 3 2002-433 200 (8 x 25)
1 - 4 2002-434 200 (8 x 25)
1 - 5 2002-435 100 (4 x 25)
: :
1 - 10 2002-440 100 (4 x 25)
50 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks
yellow 2002-115 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 5-5.2 mm terminal block width
plain
793-5501 5
39
?
Triple Deck Terminal Blocks 2.5 (4) mm2/AWG 12
2002 Series
50
50
<_ 69.5 mm /2.74‑in _>
<___ 81.5 mm /3.21in ____>
Through/through terminal block,
without marking carrier, housing color gray
2002-3201
L /L /L 4
L/L/N 4
2002-3203
<_____ 93.5mm /3.68in _____>
Item
Pack.-unit
No.
pcs
6-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
L 4
2002-3238 50
Item
Pack.-unit
No.
pcs
Through/through/through terminal block,
with marking carrier, housing color blue
N/N/N 4
2002-3234
50
Through/through terminal block,
without marking carrier, housing color blue
N/N/N 4
2002-3204
50
40
Ground conductor/through terminal block,
without marking carrier, housing color gray
PE/N/L 4
2002-3217
PE/L/L 4
2002-3227
50
50
<_____ 93.5mm /3.68in _____>
<_____ 93.5mm /3.68in _____>
Item
Pack.-unit
No.
pcs
6-conductor through terminal block,
with marking carrier, internal commoning, conductor entry
position colored in violet, housing color blue
N 4
2002-3239 50
6-conductor through terminal block,
6-conductor through terminal block,
without marking carrier, internal commoning, conductor entry without marking carrier, internal commoning, conductor entry
position colored in violet, housing color gray
position colored in violet, housing color blue
L 4
2002-3208
50
N 4
2002-3209
50
Accessories
Item
Pack.-unit
No.
pcs
Ground conductor/through/through terminal block,
with marking carrier, housing color gray
PE/N/L 4
2002-3247
50
PE/L/L 4
2002-3257
50
<_ 69.5 mm /2.74‑in _>
<___ 81.5 mm /3.21in ____>
Item
Pack.-unit
No.
pcs
Through/through/through terminal block,
with marking carrier, housing color gray
2002-3231
50
L /L /L 4
L/L/N 4
2002-3233
50
<_ 69.5 mm /2.74‑in _>
<___ 81.5 mm /3.21in ____>
<_____ 93.5mm /3.68in _____>
<_____ 93.5mm /3.68in _____>
<_ 69.5 mm /2.74‑in _>
<___ 81.5 mm /3.21in ____>
<_____ 93.5mm /3.68in _____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
500 V/6 kV/3
IN 24 A (28 A)
Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
<_ 69.5 mm /2.74‑in _>
<___ 81.5 mm /3.21in ____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
500 V/6 kV/3
300 V, 20 A U
600 V, 20 A 2 IN 24 A (28 A)
Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
<_ 69.5 mm /2.74‑in _>
<___ 81.5 mm /3.21in ____>
0.25 – 2.5 (4) mm2 AWG 22 – 12
500 V/6 kV/3
300 V, 20 A U IN 24 A (28 A)
600 V, 20 A 2 Terminal block width 5.2 / 0.205 in
L 10 – 12 mm / 0.43 in
Item
No.
6-conductor ground terminal block,
with marking carrier, internal commoning
Housing color green-yellow
PE 4
2002-3237 6-conductor ground terminal block,
without marking carrier, internal commoning
Housing color green-yellow
PE 4
2002-3207
Pack.-unit
pcs
50
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 0.7 mm thick
orange 2002-3292 100 (4 x 25)
gray 2002-3291 100 (4 x 25)
Triple-deck marker carrier,
pivotable, gray
2002-131
Push-in type jumper bars, light gray, insulated, IN 14 A
2-way 2002-402 200 (8 x 25)
3-way 2002-403 200 (8 x 25)
4-way 2002-404 200 (8 x 25)
5-way 2002-405 100 (4 x 25)
:
:
10-way 2002-410 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 14 A
1 - 3 2002-433 200 (8 x 25)
1 - 4 2002-434 200 (8 x 25)
1 - 5 2002-435 100 (4 x 25)
: :
1 - 10 2002-440 100 (4 x 25)
50 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks
yellow 2002-115 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 5-5.2 mm terminal block width
plain
793-5501 5
?
Quadruple Deck, Rail-Mounted Terminal Blocks or
Rail-Mounted Terminal Blocks for Wiring of Electric Motors, 2002 Series/AWG 12
mm2​
0.25 — 2.5 (4)
800 V/8 kV/3 IN 24 A AWG 22 — 12​
mm2​
Terminal block width 5.2 mm / 0.205 in​
L 10 — 12 mm / 0.43 in​
<_____ 103,5 mm /4.08 in ____>
Item no.​
mm2​
AWG 22 — 12​
Terminal block width 5.2 mm / 0.205 in​
L 10 — 12 mm / 0.43 in​
<____ 83,9 mm / 3.3 in____>
96,8 mm / 3.8 in
<____ 83,9 mm / 3.3 in____>
96,8 mm / 3.8 in
Terminal block width 5.2 mm / 0.205 in​
L 10 — 12 mm / 0.43 in​
0.25 — 2.5 (4)
800 V/8 kV/3 IN 24 A AWG 22 — 12​
<____ 83,9 mm / 3.3 in____>
96,8 mm / 3.8 in
0.25 — 2.5 (4)
800 V/8 kV/3 IN 24 A <_____ 103,5 mm /4.08 in ____>
Pack. unit​
Item no.​
<_____ 103,5 mm /4.08 in ____>
Pack. unit​​
Item no.​
Pack. unit​​
Quadruple-deck, rail-mounted terminal block
or
Rail-mounted terminal block for wiring of electric
motors,
without marker carrier, gray
L1 - L2 - L3 - PE
2002-4127
25
Quadruple-deck, rail-mounted terminal block
or
Rail-mounted terminal block for wiring of electric
motors,
without marker carrier, gray
L1 - L2 2002-4111
25
Quadruple-deck, rail-mounted terminal block
or
Rail-mounted terminal block for wiring of electric
motors,
without marker carrier, gray
L1 - L2 - L3 2002-4101
25
Quadruple-deck, rail-mounted terminal block
or
Rail-mounted terminal block for wiring of electric
motors,
with marker carrier, gray
L1 - L2 - L3 - PE 2002-4157
25
​
Quadruple-deck, rail-mounted terminal block
or
Rail-mounted terminal block for wiring of electric
motors,
with marker carrier, gray L1 - L2
2002-4141
25
Quadruple-deck, rail-mounted terminal block
or
Rail-mounted terminal block for wiring of electric
motors,
with marker carrier, gray
L1 - L2 - L3
2002-4131
25
Appropriate marking systems: WMB/Marking
Strips (see pages 96 -101)
​
Accessories
End and intermediate plate, 1 mm thick​
orange​ 2002-4192100 (4 x 25)
gray​
2002-4191100 (4 x 25)
Protective warning marker, with high voltage symbol,
for 5 terminal blocks​
yellow​ 2002-115 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​
2-
2002-402 200 (8 x 25)
3-
2002-403 200 (8 x 25)
4-
2002-404 200 (8 x 25)
5-
2002-405 100 (4 x 25)
:​
:​
10-
2002-410 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​
1-3 2002-433 200 (8 x 25)
1-4​
2002-434 200 (8 x 25)
1-5
2002-435 100 (4 x 25)
::
1-10 2002-440 100 (4 x 25)
Lockout cap,
Triple-deck marker carrier
pivoting
gray
2002-131
50 (2 x 25)
For motor and sensor applications
for conductor entry and operating
slot
orange​ 2002-192
25
gray
2002-191
25
blue
2002-194
25
Star point jumper, insulated,
IN = IN terminal block, light gray
1-3-52002-405/011-000
100 (4 x 25)
Delta jumper, insulated,
IN = IN terminal block, light gray
1-3 3-4 5-6 2002-406/020-000
100 (4 x 25)
Adjacent jumper for continuous commoning,
insulated, IN 25 A
light gray
2-way
2002-400 100 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 5-5.2 mm terminal block width
plain
793-5501 5
41
Movable knife
disconnects clearly
indicate the circuit
state.
2- and 4-conductor disconnect terminal blocks
The 5.2 mm wide 2- and 4-conductor disconnect
terminal blocks, that can be used in both control and
process measurement systems as well as transformer
circuits, are an addition to the range of TOPJOB®S
rail-mounted terminal blocks.
Two lateral and one center marker receptacle
for WMB markers or marking strips. Dual jumper slots, in the same position as the other 2002
Series terminal blocks. Commoning options in
front of or behind the knife disconnect, depending on which is the power supply side.
Double deck double disconnect terminal blocks
Disconnect terminal blocks of different potentials are
accommodated on two levels in a double deck disconnect
terminal block. This results in a space saving arrangement
without compromising the clarity of operation. The knife
disconnects are located between the conductors and are
therefore always in full view of the operator.
Disconnect terminal block for test and measurement, with knife disconnect, mechanical interlock and extra jumper location.
One disconnect and one through terminal
block are accommodated on two levels in a
terminal block that is only 5.2 mm wide.
42
Disconnect and ground conductor disconnect terminal blocks
Through terminal blocks and
disconnect terminal blocks
up to 8 AWG (6 mm2)
Fuse terminal blocks
Fuse terminal for automotive fuse
according to DIN 72581-3f
Fuse disconnect terminal with
pivoting fuse holder for 5 x 20 mm
and ¼" x 1 ¼" fuses
Double-deck fuse and disconnect terminal blocks
Terminal blocks combining functions
of fusing or disconnect on upper level
and through or ground connections
on lower level save valuable space
on the DIN-rail
Pivoting fuse holder to locked open position
43
?
Disconnect Terminal Blocks for Test and Measurement with
Movable Knife Disconnect and Through Terminal Blocks, 2002 Series
0.25 – 2.5 (4)
400 V/6 kV/3
16 A
mm2 0.25 – 2.5 (4)
400 V/6 kV/3
IN 16 A
AWG 22 – 12
300 V, 15 A U
600 V, 10 A 2 Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<_________ 66.5 mm /2.61 in _________>
mm2 AWG 22 – 12
300 V, 15 A U
600 V, 10 A 2
/
<___ 33‑mm
1.29 in ___>
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
/
<___ 33‑mm
1.29 in ___>
/
<___ 33‑mm
1.29 in ___>
<___ 38‑mm /1. 49‑in ___>
0.25 – 2.5 (4) mm2 AWG 22 – 12
300 V, 15 A U
400 V/6 kV/3 16 A
600 V, 10 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
!1
<_________ 66.5 mm /2.61 in _________>
<_________ 66.5 mm /2.61 in _________>
97
ItemPack.-unit
No.pcs
2-conductor disconnect terminal block for test and
measurement
2002-1671
gray
blue
2002-1674
2002-1672
orange
Carrier terminal block with disconnect plug in operating
position.
Application example showing a 2-conductor carrier terminal block 2002-1661 with disconnect plug
Item-specific accessories
End and intermediate plate, 1 mm /0.039 in thick
orange 2002-1692100 (4 x 25)
gray
2002-1691100 (4 x 25)
ItemPack.-unit
No.pcs
2-conductor disconnect terminal block for test and
measurement with mechanical interlock,
with test point,
orange disconnect
link
2002-1671/401-000
gray
blue 2002-1674/401-000
2002-1672/401-000
orange End and intermediate plate, 1 mm /0.039 in thick
orange 2002-1692100 (4 x 25)
gray
2002-1691100 (4 x 25)
ItemPack.-unit
No.pcs
2-conductor through terminal blocks,
profile as disconnect terminal block
same
gray
2002-1601
sizes: 0.25
mm¤ o 4 mm¤ is + f-stw;
2002-1604
1 Conductor
blue
Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw
2002-1602
orange
and
0.75
mm¤
o
2.5
mm¤
iinsulated ferrules, 12 mmw
2 400 V = rated voltage
6 kV = rated surge voltage
1 Conductor sizes: 0.25 mm¤ o
Push-in conductor sizes: 0.75
and 0.75 mm¤ o 2.5 mm¤
iinsulated ferrules, 12 mmw
3 = pollution degree
(see Section 14)
2 400 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(see Section 14)
3 Strip length, see packaging or instructions.
4 See application notes for:
Colored push-in type jumper bars, page 139
Carrier
terminaljumper,
block with
plug in operating
Staggered
pagedisconnect
141
3
position.
Adjacent jumper for continuous commoning,
Application
example showing a 2-conductor carrier termi4
page
139
Endnaland
intermediate
plate,
1 mmplug
/0.039 in thick
block
2002-1661
with
disconnect
Push-in type wire jumper, page 140
orange
2002-1692
1
00
(4
x
25)
¥
TOPJOB S connector, page 134
plug module,
page 136
TOPJOB¥S L-type test
gray
2002-1691
100 (4 x 25)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Accessories
200 strips
Insulation stop, 5 pcs/strip
light gray2002-171 0.25-0.5 mm2
dark gray2002-172 0.75-1 mm2
Protective warning marker,
for 5 terminal blocks
yellow 2002-115 100 (4 x 25) Push-in type jumper bars, light gray, insulated, IN 25 A
2-way 2002-402200 (8 x 25)
3-way 2002-403200 (8 x 25)
4-way 2002-404200 (8 x 25)
5-way 2002-405100 (4 x 25)
:
:
10-way 2002-410100 (4 x 25)
Slim style jumper, light gray, insulated, IN 25 A
2-way 2002-472100 (4 x 25)
3-way 2002-473100 (4 x 25)
4-way 2002-474100 (4 x 25)
terminal
2002-475
x 25)
5-way
2-conductor disconnect
block50
for(2test
and
measurement, with
disconnect
and mechanical
: knife :
interlock
2002-482
50
(2
x
25)
12-way
Open position
Push-in type jumper bars, light gray, insulated, IN 25 A
Test plug adapter, for test plug 4 mm/0.157 in Ø
2009-174
100 (4 x 25)
215-111
50
Strip length, see packaging o
See application notes for:
Colored push-in type jumper
Staggered jumper, page 141
Adjacent jumper for continuo
page 139
Push-in type wire jumper, pag
TOPJOB¥S connector, page 1
TOPJOB¥S L-type test plug m
1 - 3 2002-433200 (8 x 25)
1 -adapter,
4 2002-434200 (8 x 25)
Test plug
2002-435100
1 - 5 for
test plug 4 mm (4 x 25)
: gray
:
2009-174 100 (4x25)
Testfor
plug
adapter,
max.
2.5 mm2
1 - 10 2002-440100 (4 x 25) Testing tap,
for test plug 4 mm  100 (4 x 25)
Testing tap,
2009-182
gray
2009-174 100 (4x25)
for max. 2.5 mm¤
Two-way marking adapter,
Modular TOPJOB®S connector**,
gray
2009-182 100 (4x25)
for jumper contact slot
pivotable
Testing tap,
2002-121
50 (4 x 25)
1
pole 2002-511100 (4 x 25) for max. 2.5 mm¤
Banana plug,
gray
2009-182 100 (4x25)
for socket 4 mm ,
2002-549100
(4 x 25)
Spacer, modular color
mixed
1
!
2-conductor
disconnect
terminal block
for testblock
and
2-conductor
disconnect
terminal
measurement, with knife disconnect and mechanical
for test and measurement, with knife
interlock
Open position
disconnect and mechanical interlock
(open position)
Banana plug,
for socket 4 mm ,
Double-deck
Test plug, with cable
500‑mmmarker
/1’7.7’’carrier,
color mixed
2-conductor
disconnect
terminal
2-conductor disconnect
terminal block for test and
2-conductor
disconnect
terminal block
for testblock
and
pivoting
2 mm/0.079
in Ø
measurement,
with
knife disconnect
and mechanical
215-111
50 measurement, with knife disconnect and mechanical
gray
2002-121
for test and measurement, with knife
red210-136
50
(5 x 10) 50 (2x25) interlock
interlock
Double-deck marker carrier,
44
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
Marking strip, plain,
11 mm wide,
50 m roll
Top view
5
pivoting
gray
2002-121
Closing
of knife disconnect
disconnect
and mechanical
2-conductor
disconnect
terminal block interlock
for test and
with
knife
disconnect and mechanical
50 (2x25) measurement,
(closing
of
knife
disconnect)
interlock
Top view
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
Marking strip, plain,
5
2-conductor disconnect termin
measurement, with knife disc
interlock
Closing of knife disconnect
?
TOPJOB¥@
Disconnect
TerminalBlocks
Blocksfor
with
Mechanical
Disconnect Terminal
Testand
andwithout
Measurement
withoutInterlock
and with
with
Additional
Jumper
Position,
2002
Series
Mechanical Interlock with Additional Jumper Position 2.5 (4) mm¤, 2002 Series
102
0.25 - 2.5 (4) mm¤ 12 AWG
22 - 12
0.25 – 2.5 (4)
mm AWG 22 – 12
2
400
300 V, 15 A U
400V/6
V/6kV/3
kV/3 IN16
16A
A
600 V, 10 A 2
Terminal
in in
Terminalblock
blockwidth
width5.2
5.2mm
mm/ 0.205
/ 0.205
L1010
– mm
12 mm
/ 0.43
- 12
/ 0.43
in 3in
L
32,9 mm/1.3 in
37,9 mm/1.49 in
40,8 mm/1.61 in
72,9 mm/2.87 in
Item No.
Ǔ
Ǔ
Ǔ
0.25 - 2.5 (4) mm¤ 1
0.25 – 2.5 (4)2mm2 400
400 V/6
V/6 kV/3
kV/3
IINN 16
16 AA
Item No.
2-conductor disconnect terminal block for test and
measurement,
with test point, orange disconnect link,
with additional jumper position
gray
2002-1971
50
blue
2002-1974
50
orange
2002-1972
50
300 V, 15 A U
600 V, 10 A 2
Terminal block width 5.2 mm / 0.205 in
Terminal block width 5.2 mm / 0.205 in
- 12
mmmm
/ 0.43
in 3
L
L 1010
– 12
/ 0.43
in
40,8 mm/1.61 in
72,9 mm/2.87 in
Pack.
Unit
AWG 22 - 12
AWG 22 – 12
32,9 mm/1.3 in
38,9 mm/1.53 in
Terminal
mm
/ 0.205
in in
Terminalblock
blockwidth
width5.2
5.2
mm
/ 0.205
L10 10
12 mm
/ 0.43
- 12– mm
/ 0.43
in 3in
L
0.25 - 2.5 (4) mm¤ 1
AWG 22 - 12
mm2 AWG 22 – 12
0.25 – 2.5 (4)
2
400
300 V, 15 A U
400V/6
V/6kV/3
kV/3
IN16
16AA
600 V, 10 A 2 32,9 mm/1.3 in
1
Ǔ
Ǔ
Ǔ
40,8 mm/1.61 in
72,9 mm/2.87 in
Pack.
Unit
2-conductor disconnect terminal block for test and
measurement with mechanical interlock,
with test point, orange disconnect link,
with additional jumper position
gray
2002-1971/401-000
50
orange
2002-1972/401-000 50
50
blue
2002-1974/401-000
blue
2002-1974/401-000 50
2002-1972/401-000
orange
Item No.
Pack.
Unit
2-conductor through terminal block,
with test point, with additional jumper position,
same profile as 2-conductor disconnect terminal block
Ǔ
Ǔ
Ǔ
gray
blue
orange
2002-1901
2002-1904
2002-1902
50
50
50
Ǔ
2-conductor ground terminal block
green-yellow
2002-1907
50
Ǔ
Ǔ
2002 Series Accessories
Accessories
Other terminal blocks with the same profile:
Carrier
2002-1961 Page
PageǓ114
47
40
Fuse
2002-1981 Page
PageǓ105
Appropriate
marking systems:
WMB/Marking
strips/WMB Inline
Appropriate
marking
systems: WMB/Marking
Strips (see pages 96 -101)
(see Section 13)
End and intermediate plate, 1 mm thick
orange
2002-1992 100 (4x25)
gray
2002-1991 100 (4x25)
Push-in type jumper bar, insulated,
IN 25 A,
light gray
from 1 to 3
2002-433
from 1 to 4
2002-434
from 1 to 5
2002-435
from 1 to 6
2002-436
from 1 to 7
2002-437
from 1 to 8
2002-438
from 1 to 9
2002-439
from 1 to 10 2002-440
200
200
Insulation stop,
100
5 pcs/strip,
100
0.25 - 0.5 mm¤
100
light gray
2002-171 200 (8x25)
100
Insulation stop,
100
5 pcs/strip,
100
0.75 - 1 mm¤
dark gray
2002-172 200 (8x25)
Push-in type jumper bar, insulated,
Staggered
jumper,
Slim
style jumper,
4
4
insulated,
IN 25 A,
IN 25 A,
light gray
light gray
2-way
2002-402 200 (8x25)
3-way
2002-403 200 (8x25)
2-way
2002-472 100
4-way
2002-404 200 (8x25)
3-way
2002-473 100
5-way
2002-405 100 (4x25)
4-way
2002-474 100
6-way
2002-406 100 (4x25)
5-way
2002-475
50
7-way
2002-407 100 (4x25)
6-way
2002-476
50
8-way
2002-408 100 (4x25)
7-way
2002-477
50
9-way
2002-409 100 (4x25)
8-way
2002-478
50
10-way
2002-410 100 (4x25)
9-way
2002-479
50
10-way
2002-480
50
Push-in type wire jumper,
4
11-way
2002-481
50
insulated,
12-way
2002-482
50
IN 16 A,
wire size 1.5 mm¤
L = 60 mm
2009-412 100 (10x10) Adjacent jumper for continuous commoning,
L = 110 mm 2009-414 100 (10x10) 4
insulated, I N 25 A,
L = 250 mm 2009-416 100 (10x10)
light gray
2-way
2002-400 100
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2002-115 100 (4x25)
Test plug adapter,
for test plug 4 mm 
gray
2009-174 100 (4x25)
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25) Testing tap,
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
for max. 2.5 mm¤
gray
2009-182
100 (4x25)
Modular TOPJOB¥S connector,
4
can be snapped together,
for jumper contact slot
gray
2002-511 100 (4x25)
Spacer module, can be snapped together,
e.g., for bridging commoned terminal
blocks
gray
2002-549 100 (4x25)
End plate,
for modular TOPJOB¥S connectors,
1.5 mm thick
gray
2002-541 100 (4x25)
TOPJOB¥S test plug module,
4
can be snapped together
gray
2002-611 100 (4x25)
Test plug,
(4x25)
with 500 mm cable,
2 mm 
red
210-136
50
For list of approvals and user guide, see pages 634 to 637.
45
?
Disconnect Terminal Blocks for Test and Measurement with
Movable Knife Disconnect and Through Terminal Blocks, 2002 Series
0.25 – 2.5 (4)
400 V/6 kV/3
IN 16 A
2
AWG 22 – 12
0.25 – 2.5 (4) mm 300 V, 15 A U
400 V/6 kV/3
16 A
600 V, 15 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
AWG 22 – 12
300 V, 15 A U
600 V, 10 A 2
/
<___ 33‑mm
1.29 in ___>
/
<___ 32.9‑mm
1.3 in ___>
<___
!1
<______________ 87.5 mm /3.45 in ______________>
<______________ 87.5 mm /3.45 in ______________>
mm2 Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
38.9‑mm / ___>
1.53 in
/
<___ 33‑mm
1.29 in ___>
<___ 38‑mm /1. 49‑in ___>
0.25 – 2.5 (4) mm2 AWG 22 – 12
300 V, 15 A U
400 V/6 kV/3 16 A
600 V, 15 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<______________ 87.5 mm /3.45 in ______________>
97
ItemPack.-unit
No.pcs
4-conductor disconnect terminal block for test and
measurement
2002-1871
2002-1874
2002-1872
gray blue
orange ItemPack.-unit
No.pcs
4-conductor disconnect terminal block for test and
measurement with mechanical interlock,
with test point,
orange disconnect link
2002-1871/401-000 50
gray
blue 2002-1874/401-000 50
2002-1872/401-000 50
orange
4-conductor through terminal blocks,
same profile as disconnect terminal block
End and intermediate plate, 1 mm /0.039 in thick
orange 2002-1892100 (4 x 25)
gray
2002-1891100 (4 x 25)
1 Conductor sizes: 0.25 mm¤ o 4
Push-in conductor sizes: 0.75 m
and 0.75 mm¤ o 2.5 mm¤
iinsulated ferrules, 12 mmw
2 400 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(see Section 14)
2 400 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(see Section 14)
3 Strip length, see packaging or instructions.
4 See application notes for:
Colored push-in type jumper bars, page 139
Carrier
terminaljumper,
block with
plug in operating
Staggered
pagedisconnect
141
3
position.
Adjacent jumper for continuous commoning,
Application
example showing a 2-conductor carrier termi4
page
139
End
1 mm /0.039 in thick
nal and
blockintermediate
2002-1661
withplate,
disconnect
Push-in
type wire jumper,
page 140plug
orange
2002-1892100 (4 x 25)
page 134
TOPJOB¥S connector,
plug module,
page 136100 (4 x 25)
TOPJOB¥S L-type testgray
2002-1891
End and intermediate plate, 1 mm /0.039 in thick
orange 2002-1892100 (4 x 25)
gray
2002-1891100 (4 x 25)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Accessories
200 strips
Insulation stop, 5 pcs/strip
light gray2002-171 0.25-0.5 mm2
dark gray2002-172 0.75-1 mm2
Protective warning marker,
for 5 terminal blocks
yellow 2002-115 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A
2-way 2002-402200 (8 x 25)
3-way 2002-403200 (8 x 25)
4-way 2002-404200 (8 x 25)
5-way 2002-405100 (4 x 25)
:
:
10-way 2002-410100 (4 x 25)
Slim style jumper, light gray, insulated, IN 25 A
2-way 2002-472100 (4 x 25)
3-way 2002-473100 (4 x 25)
4-way 2002-474100 (4 x 25)
2-conductor disconnect terminal
block 50
for test
2002-475
(2 xand
25)
5-way
measurement, with knife disconnect and mechanical
:
:
interlock
2002-482 50 (2 x 25)
12-way
Open position
Push-in type jumper bars, light gray, insulated, IN 25 A
Test plug adapter, for test plug 4 mm/0.157 in Ø
2009-174
100 (4 x 25)
215-111
50
Strip length, see packaging or i
See application notes for:
Colored push-in type jumper ba
Staggered jumper, page 141
Adjacent jumper for continuous
page 139
Push-in type wire jumper, page
TOPJOB¥S connector, page 13
TOPJOB¥S L-type test plug mod
1 - 3 2002-433200 (8 x 25)
1adapter,
- 4 2002-434200 (8 x 25)
Test plug
test plug 4 mm  (4 x 25)
1 - 5for2002-435100
2009-174 100 (4x25)
: gray
:
Test plug adapter,
1 - 10 2002-440100 (4 x 25) Testing tap, for max. 2.5 mm2
for test plug 4 mm 
Testing tap,
2009-182
100 (4 x 25)
gray
2009-174 100 (4x25)
for max. 2.5 mm¤
Two-way
marking
adapter,
Modular TOPJOB®S connector**,
gray
2009-182 100 (4x25)
for jumper contact slot
Testing tap, pivotable
2002-121
50 (4 x 25)
1
pole 2002-511100 (4 x 25) for max. 2.5 mm¤
Banana plug,
gray
2009-182 100 (4x25)
for socket 4 mm ,
mixed
2002-549100
(4 x 25)
Spacer, modular color
1
1 Conductor sizes: 0.25 mm¤ o 4 mm¤ is + f-stw;
2002-1801
gray Push-in conductor sizes:
0.75 mm¤ o 4 mm¤ isw
mm¤
blue
and 0.75 mm¤ o 2.5
2002-1804
iinsulated ferrules, 12 mmw
2002-1802
orange Carrier terminal block with disconnect plug in operating
position.
Application example showing a 2-conductor carrier terminal block 2002-1661 with disconnect plug
Item-specific accessories
ItemPack.-unit
No.pcs
!
2-conductor
disconnect
terminal block
for testblock
and
2-conductor
disconnect
terminal
measurement, with knife disconnect and mechanical
for test and measurement, with knife
interlock
Open position
disconnect and mechanical interlock
(open position)
Banana plug,
for socket 4 mm ,
marker carrier,
Test plug, with Double-deck
cable 500‑mm
/1’7.7’’
color mixed
2-conductor
disconnect
terminal
2-conductor disconnect
terminal block for test and
2-conductor
disconnect
terminal block
for testblock
and
pivoting
2 mm/0.079 in Ø
and mechanical
215-111
50 measurement, with knife disconnect and mechanical
gray
2002-121
50 (2x25) measurement, with knife disconnect
for
test
and
measurement,
with
knife
interlock
interlock
red210-136
50 (5 x 10)
Double-deck marker carrier,
46
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
Marking strip, plain,
11 mm wide,
50 m roll
Top view
5
pivoting
gray
2002-121
Closing
of knife disconnect
disconnect
and mechanical
2-conductor
disconnect
terminal block interlock
for test and
knife
disconnect and mechanical
50 (2x25) measurement,
(closing ofwith
knife
disconnect)
interlock
Top view
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
2-conductor disconnect termina
measurement, with knife discon
interlock
Closing of knife disconnect
?
Double Deck Double Disconnect Terminal Blocks for Test
and Measurement with Movable Knife Disconnect, 2002 Series
/
<___ 42‑mm
1.65 in ___>
<
_
_
_
47.5‑mm /1. 87‑in ___>
Double-Deck Disconnect Terminal Blocks
with Movable Knife Disconnect
<______________ 108 mm /4.25 in ______________>
ItemPack.-unit
No.pcs
4-conductor double deck double disconnect
terminal blocks
gray blue gray N/L Ciruit:
2002-2951
2002-2954
2002-2952
2
AWG 22 – 12
0.25 – 2.5 (4) mm 300 V, 15 A U
400 V/6 kV/3
16 A
300 V, 15 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<______________ 108 mm /4.25 in ______________>
ItemPack.-unit
No.pcs
4-conductor double deck double disconnect terminal
blocks, lower deck and upper deck internally commoned
on right side and with violet marking
block assembly
gray
Terminal
2002-2958
blue
2002-2959
Circuit:
<______________ 108 mm /4.25 in ______________>
Item-specific accessories
End and intermediate plate, 1 mm /0.039 in thick
orange 2002-2992100 (4 x 25)
gray
2002-2991100 (4 x 25)
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
200 strips
Insulation stop, 5 pcs/strip
light gray2002-171 0.25-0.5 mm2
dark gray2002-172 0.75-1 mm2
Protective warning marker,
for 5 terminal blocks
yellow 2002-115100 (4 x 25)
Push-in
light
Testingtype
with jumper
test plugbars,
2 mm
.gray, insulated, IN 25 A
Push-in type jumper bars, light gray, insulated, IN 25 A
2-way 2002-402200 (8 x 25)
3-way 2002-403200 (8 x 25)
4-way 2002-404200 (8 x 25)
5-way 2002-405100 (4 x 25)
:
:
10-way 2002-410100 (4 x 25)
Modular TOPJOB®S connector**,
for jumper contact slot
1 pole 2002-511100 (4 x 25)
2002-549100 (4 x 25)
Spacer, modular
1 Conductor sizes: 0.25 mm
Push-in conductor sizes: 0.
and 0.75 mm¤ o 2.5 mm¤
iinsulated ferrules, 12 mm
ItemPack.-unit
2
No.pcs
4-conductor double deck disconnect terminal blocks,
with disconnect on uper deck only, same profile as double
3
deck double disconnect terminal blocks
gray
2002-2971
4
blue
2002-2974
gray
2002-2972
N/L
Circuit:
End and intermediate plate, 1 mm /0.039 in thick
orange 2002-2992100 (4 x 25)
gray
2002-2991100 (4 x 25)
1 - 3
1 - 4
1 - 5
:
1 - 10
2002-433200 (8 x 25)
2002-434200 (8 x 25)
2002-435100 (4 x 25)
:
2002-440100 (4 x 25)
Strip length, see packagin
See application notes for:
Colored push-in type jump
Star point jumper, page 1
Delta jumper, page 140
Staggered jumper, page 1
Adjacent jumper for contin
page 139
Push-in type wire jumper, p
TOPJOB¥S connector, pag
TOPJOB¥S L-type test plug
Accessories
10 strips wit
stretchable 5
plain
Test plug, with cable 500‑mm /1’7.7’’
WMB Multi marking syste
2 mm/0.079 in Ø
10 strips wit
red210-136
50 (5 x 10)
stretchable 5
yellow
Slim style
jumper
, light
gray, insulated,inINjumper
25 A
Group
marker
carrier
accommodated
red
contact
slot.
2-way
2002-472100 (4 x 25)
blue
3-way 2002-473100 (4 x 25)
gray
4-way 2002-474100 (4 x 25)
orange
5-way 2002-475 50 (2 x 25)
light green
green
:
:
violet
12-way 2002-482 50 (2 x 25)
100 (4 x 25)
Carrier terminal block 2002-2961 with disconnect plug
2002-401 in parked position.
400 V = rated voltage
6 kV = rated surge volta
3 = pollution degree
(also see Section 14)
End and intermediate plate, 1 mm /0.039 in thick
orange 2002-2992100 (4 x 25)
gray
2002-2991100 (4 x 25)
WMB Multi marking syste
Test plug adapter, for test plug 4 mm/0.157 in Ø
2009-174
100 (4 x 25)
Testing tap, for max. 2.5 mm2
2009-182
!
/
<___ 42‑mm
1.65 in ___>
<
_
_
_
47.5‑mm /1. 87‑in ___>
2
AWG 22 – 12
0.25 – 2.5 (4) mm 300 V, 15 A U
400 V/6 kV/3
16 A
300 V, 15 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
/
<___ 42‑mm
1.65 in ___>
<
_
_
_
47.5‑mm /1. 87‑in ___>
0.25 – 2.5 (4) mm2 AWG 22 – 12
300 V, 15 A U
400 V/6 kV/3 16 A
300 V, 15 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Carrier terminal block 2002-2961 with disconnect plug
Carrierinterminal
block 2002-2961 with
2002-401
operating position.
disconnect plug 2002-401 in operating
position. See page 52.
WMB Inline, plain,
stretchable 5
1,500 WMB
white
TOPJOB¥S group marker c
snap-on type
5 mm wide
gray
Screwless end stop,
for DIN 35 r
6 mm wide
gray
Screwless end stop,
for DIN 35 r
10 mm wide
gray
47
?
Fuse Terminal Blocks for (Mini-Automotive) Blade-Type Fuses
acc. to DIN 72581-3f, ISO 8820-3, 2002 ​Series
0.25 — 2.5 (4)
400 V/6 kV/3
IN 10 A​
AWG 22 — 12​
300 V, 10 A U
600 V, 6.3 A 2
Terminal block width 5.2 mm / 0.205 in​
L 10 — 12 mm / 0.43 in​
mm2​
AWG 22 — 12​
300 V, 10 A U
600 V, 6.3 A 2
<________ 66,5 mm/2.61 in _______>
Item no.​
AWG 22 — 12​
300 V, 10 A U
600 V, 6.3 A 2
Terminal block width 5.2 mm / 0.205 in​
L 10 — 12 mm / 0.43 in​
<________77.9 mm /2.87 in ________>
<______________ 87,5 mm/3.45 in _____________>
Pack. unit​​
Item no.​
Pack. unit​​
4-conductor fuse terminal blocks​
2-conductor fuse terminal blocks​
gray​ mm2​
( 33 mm/ 1.29 in )
(__ 33 mm/1.29 in _)
<__ 38 mm/1.49 in __>
Terminal block width 5.2 mm / 0.205 in​
L 10 — 12 mm / 0.43 in​
0.25 — 2.5 (4)
400 V/6 kV/3
IN 10 A​
32.9‑mm /
1.3 in ___>
mm2​
<___
0.25 — 2.5 (4)
400 V/6 kV/3
IN 10 A​
2002-1681
gray​ 2002-1881
2-conductor fuse terminal blocks​
gray​ 2002-1981
Article-specific accessories​
End and intermediate plate, 1 mm/0.039 in thick​
orange​ 2002-1692100 (4 x 25)
gray​
2002-1691100 (4 x 25)
Accessories
End and intermediate plate, 1 mm/0.039 in thick​
orange​ 2002-1892100 (4 x 25)
gray​
2002-1891100 (4 x 25)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Insulation stop, 5 pcs/strip​
200 strips​ Protective warning marker, with high voltage symbol, black,
for 5 terminal blocks​
light gray​ 2002-171 0.25-0.5 mm2​
dark gray​ 2002-172 0.75-1 mm2​ yellow​ 2002-115 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​ Slim style jumpers, light gray, insulated, IN 25 A​
2-way​ 2002-402 200 (8 x 25) 2-way​ 2002-472 100 (4 x 25)
3-way​ 2002-403 200 (8 x 25) 3-way​ 2002-473 100 (4 x 25)
4-way​ 2002-404 200 (8 x 25) 4-way​ 2002-474 100 (4 x 25)
5-way​ 2002-405 100 (4 x 25) 5-way​ 2002-475 50 (2 x 25)
:​
:​
:​
:​
10-way​ 2002-410 100 (4 x 25) 12-way​ 2002-482 50 (2 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​ Test plug adapter, for test plug Ø 4 mm/0.157 in​
2009-174
100 (4 x 25)
1 - 3​ 2002-433 200 (8 x 25) 1 - 4​ 2002-434 200 (8 x 25)
1 - 5​ 2002-435 100 (4 x 25)
:​
:​
1 - 10​ 2002-440 100 (4 x 25) Testing tap, for max. 2.5 mm2/AWG 14​
2009-182
100 (4 x 25)
Two-way marking adapter,
Modular TOPJOB®S connector,
for jumper contact slot​
pivotable​
1 pole​ 2002-511 100 (4 x 25) 2002-121
50 (2 x 25)
Spacer, modular​2002-549
100 (4 x 25)
Blade-type fuses acc. to DIN 72581-3f /
ISO 8820-3 (contact WAGO)​
48
End and intermediate plate, 1 mm/0.039 in thick​
orange​ 2002-1992100 (4 x 25)
gray​
2002-1991100 (4 x 25)
Test plug, with cable 500mm/1’7.7’’, Ø 2 mm/0.079 in
red​
210-136 50 (5 x 10)
The rated currents of the fuse cartridges are
defined differently in international standards.
Due to the different current rating definitions,
the recommended current-carrying permanent
capacity of the fuses is max. 80% of their rated
current according to DIN 72581 part 3 (for an
ambient operating temperature of 23°C).
Selecting the correct fuse cartrigde is important
for product safety within applications as well as
the service life/operational reliability of the fuse
cartrigdes. Fuse cartrigdes can operate perfectly
as protection (break-off point) if they are properly
selected and are used in accordance with
the manufacturers specifications.
In general it is necessary to test fuse cartridges
under normal conditions and operational failures
within your application.
With regard to the product safety, it is in
general necessary to test the fuse in the
appliance under normal conditions and
operational failures.​
?
TOPJOB¥@
¥ Blocks
Fuse
Terminal
for2.5
(Mini-Automotive)
Blade-Type Fuses
1 TOPJOB
Fuse
Terminal
(4) mm¤
@ Blocks
with
Indication
Additional
Seriesor Blocks
1 2002
Fuse
Terminal
2.5 (4)Jumper
mm¤ Position, 2002 Series
104
AWG 22 — 12​
12 V, 22
10- A12U
AWG
600 V, 6.3 A 2
Terminal
IN 10 A block width 5.2 mm / 0.205 in
Terminal
block
5.2/ 0.43
mm /in 0.205
in​
3
10width
- 12 mm
L
Terminal
mmin​
/ 0.205 in
L
10 block
— 12width
mm /5.2
0.43
L 10 - 12 mm / 0.43 in 3
40,8 mm/1.61 in
72,9 mm/2.87 in
Circuit I
40,8 mm/1.61
in
Circuit
II
72,9 mm/2.87 in
Circuit I
Circuit II
Terminal
IN 10 A block width 5.2 mm / 0.205 in
Terminal
5.2 mm
10 - 12width
mm / 0.43
in 3/ 0.205 in​
L block
Terminal block
5.2 mm
/ 0.205
L
10 —width
12 mm
/ 0.43
in​ in
L 10 - 12 mm / 0.43 in 3
32,9 mm/1.3
32,9 mm/1.3
in
in
38 mm/1.5
38 mm/1.5
in
in
(4) mm¤ 1
22 - 12
0.25 — 2.5 (4) mm2​ AWGAWG
22 — 12​
400 V/6 kV/3 2
10 A U
400
(4) mm¤ 1 AWG24
0.25V/6
- 2.5kV/3
22V,
- 12
IN 10 A
IN400
10 V/6
A​ kV/3 2
600 V, 6.3 A 2
40,8 mm/1.61 in
72,9 mm/2.87 in
Circuit I
40,8 mm/1.61
in
Circuit
II
72,9 mm/2.87 in
Circuit I
Circuit II
0.25 - 2.5 (4) mm¤ 1 AWG
- 12
0.25 — 2.5 (4) mm2​ 22 AWG
22 — 12​
400 V/6 kV/3 2
400
V/6
(4)kV/3
mm¤ 1 AWG 22 48
0.25
- 2.5
- 12V, 10 A U IN 10 A
INV/6
10 kV/3
A​ 2
600 V, 6.3 A 2 400
Terminal
IN 10 A block width 5.2 mm / 0.205 in
Terminal
10 - block
12 mmwidth
/ 0.435.2
in 3mm / 0.205 in​
L
Terminal
block 10
width
5.2 mm
mm // 0.205
in
L
— 12
0.43 in​
L 10 - 12 mm / 0.43 in 3
40,8 mm/1.61 in
72,9 mm/2.87 in
Circuit I
Circuit I
32,9 mm/1.3
32,9 mm/1.3
in
in
38 mm/1.5
38 mm/1.5
in
in
0.25 - 2.5
AWG 22 - 12
32,9 mm/1.3
32,9 mm/1.3
in
in
38 mm/1.5
38 mm/1.5
in
in
mm¤
0.25 - 2.5 Series
2​ 1
2002
104
2.5 (4)(4)mm
0.25 —
400 V/6 kV/3 2
400 V/6
0.25kV/3
- 2.5 (4) mm¤ 1
IN 10 A
IN 10 400
A​ V/6 kV/3 2
40,8 mm/1.61
in
Circuit
II
72,9 mm/2.87 in
Circuit II
Pack.
Pack.
Pack.
Item No.
Item No.
Unit
Unit
Unit
Pack.
Pack.
Pack.
2-conductor fuse terminal
Itemblock
No. for mini-automotive 2-conductor fuse terminal
Itemblock
No. for mini-automotive 2-conductor fuse terminal
Itemblock
No. for mini-automotive
Unit
Unit
Unit
blade-style fuses,
blade-style fuses,
blade-style fuses,
Item No.
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
2-conductor
block
mini-automotive
12V, with test fuse
point,terminal
with blown
fusefor
indication
by LED,
blade-style
fuses,
LED power consumption:
4.8 mA, gray
12V,
with
test
point,
with
blown
fuse
indication
by LED,
Nominal voltage and current are given by the LED
or fuse.
LED power fuses,
consumption:
4.8 mA,
gray protection for
Blade-style
please note
touchproof
Nominal
42V and voltage
higher. and current are given by the LED or fuse.
Blade-style
note touchproof protection for
Circuit Ifuses, please2002-1981/1000-429
50
42VCircuit
and higher.
II
2002-1981/1000-449
50
Circuit I
2002-1981/1000-429
50
Circuit
II
Other
terminal
blocks2002-1981/1000-449
with the same profile: 50
Ǔ
Ǔ
Ǔ
Ǔ
2-conductor
terminal
block
mini-automotive
24 V, with testfuse
point,
with blown
fusefor
indication
by LED,
blade-style
fuses,
LED power consumption:
4.8 mA, gray
24
V,
with
test
point,
with
blown
fuse
indication
by or
LED,
Nominal voltage and current are given by the LED
fuse.
LED power fuses,
consumption:
4.8 mA,
gray protection for
Blade-style
please note
touchproof
Nominal
42V and voltage
higher. and current are given by the LED or fuse.
Blade-style
note touchproof protection for
Circuit Ifuses, please2002-1981/1000-413
50
42VCircuit
and higher.
II
2002-1981/1000-434
50
Circuit I
2002-1981/1000-413
50
Circuit II
2002-1981/1000-434
50
Ǔ
Ǔ
Ǔ
Ǔ
2-conductor
terminal
block
mini-automotive
48 V, with testfuse
point,
with blown
fusefor
indication
by LED,
blade-style
fuses,
LED power consumption:
4.8 mA, gray
48
V,
with
test
point,
with
blown
fuse
indication
by or
LED,
Nominal voltage and current are given by the LED
fuse.
LED power fuses,
consumption:
4.8 mA,
gray protection for
Blade-style
please note
touchproof
Nominal
42V and voltage
higher. and current are given by the LED or fuse.
Blade-style
note touchproof protection for
Circuit Ifuses, please2002-1981/1000-414
50
42VCircuit
and higher.
II
2002-1981/1000-435
50
Circuit I
2002-1981/1000-414
50
Circuit II
2002-1981/1000-435
50
Through
2002-1901
PageǓ102
Other terminal blocks with the same profile:
Page
37
Through
2002-1901
PageǓ102
2002 Series Accessories
2002 Series Accessories
Accessories
End and intermediate plate, 1 mm thick
orange
2002-1992
End and intermediate
mm thick
gray plate, 12002-1991
orange
2002-1992
2002-1991
Insulation stop,gray
Appropriate marking systems: WMB/Marking strips/WMB Inline
(see Section
13)
Appropriate
marking systems:
WMB/Marking
strips/WMB Inline
Appropriate
marking
systems: WMB/Marking
Strips (see pages 96 -101)
Push-in type wire jumper,
Staggered jumper,
(see Section 13)
100
100
100
100
(4x25)
(4x25)
(4x25)
(4x25)
5 pcs/strip,
Insulation stop,0.25 - 0.5 mm¤
5
pcs/strip,
light
gray
2002-171 200 (8x25)
Insulation stop,0.25 - 0.5 mm¤
light
gray
2002-171 200 (8x25)
5
pcs/strip,
Insulation stop,0.75 - 1 mm¤
5
pcs/strip,
dark
gray
2002-172 200 (8x25)
0.75 -bar,
1 mm¤
Push-in type jumper
insulated,
gray
2002-172 200 (8x25)
4
Idark
N 25 A,
Push-in type jumper
bar, insulated,
light gray
4
I2-way
N 25 A,
2002-402 200 (8x25)
light
gray
3-way
2002-403 200 (8x25)
2-way
2002-402
4-way
2002-404 200
200 (8x25)
(8x25)
3-way
2002-403
5-way
2002-405 200
100 (8x25)
(4x25)
4-way
2002-404
200
6-way
2002-406 100 (8x25)
(4x25)
5-way
2002-405
7-way
2002-407 100
100 (4x25)
(4x25)
6-way
2002-406
8-way
2002-408 100
100 (4x25)
(4x25)
7-way
2002-407
9-way
2002-409 100
100 (4x25)
(4x25)
8-way
2002-408
10-way
2002-410 100
100 (4x25)
(4x25)
9-way
2002-409 100 (4x25)
For list of approvals and user guide, see pages 634 to 637.
10-way
2002-410 100 (4x25)
For list of approvals and user guide, see pages 634 to 637.
4
insulated,
Push-in type wire
jumper,
A,
IN 16
4
insulated,
wire size 1.5 mm¤
ILN=16
60A,mm
2009-412 100
wire
sizemm
1.5 mm¤
L = 110
2009-414 100
LL =
= 60
250mm
mm 2009-412
2009-416 100
100
L = 110 mm 2009-414 100
L =for
250
mm 2009-416
100
Adjacent jumper
continuous
commoning,
(10x10)
(10x10)
(10x10)
(10x10)
(10x10)
(10x10)
4
insulated, I N 25 A,
Adjacent jumper
forgray
continuous commoning,
light
4
A,
insulated, I N 252002-400
2-way
100
light gray
Push-in type jumper
bar, insulated,
2-way
2002-400 100
IN 25 A,
Push-in type jumper
bar, insulated,
light gray
IN 251A,to 3
from
2002-433 200
light
from gray
1 to 4
2002-434 200
from
2002-433
from 1
1 to
to 3
5
2002-435 200
100
from
2002-434
from 1
1 to
to 4
6
2002-436 200
100
from
1
to
5
2002-435
from 1 to 7
2002-437 100
100
from
2002-436
from 1
1 to
to 6
8
2002-438 100
100
from
2002-437
from 1
1 to
to 7
9
2002-439 100
100
from
from 1
1 to
to 8
10 2002-438
2002-440 100
100
from 1 to 9
2002-439 100
from 1 to 10 2002-440 100
(4x25)
(4x25)
(8x25)
(8x25)
(8x25)
(4x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
4
insulated,
Slim style jumpers
Staggered
jumper,
IN 25 A,
4
insulated,
light
gray
I2-way
N 25 A,
light
gray
3-way
2-way
4-way
3-way
5-way
4-way
6-way
5-way
7-way
6-way
8-way
7-way
9-way
8-way
10-way
9-way
11-way
10-way
12-way
11-way
12-way
Protective warning
marker,
2002-472
2002-473
2002-472
2002-474
2002-473
2002-475
2002-474
2002-476
2002-475
2002-477
2002-476
2002-478
2002-477
2002-479
2002-478
2002-480
2002-479
2002-481
2002-480
2002-482
2002-481
2002-482
100
100
100
100
100
50
100
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(2x25)
(4x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
with high-voltage symbol, black,
Protective warning
for 5marker,
terminal blocks
with high-voltage2002-115
symbol, black,
yellow
100 (4x25)
for 5 terminal blocks
yellow
2002-115 100 (4x25)
49
?
Fuse Disconnect Terminal Blocks with Pivotable Fuse Holder
for Miniature Metric Fuses 5 x 20 mm, 2002 Series​
0.25 — 2.5 (4) mm2​ AWG 22 — 12​
250 V/6 kV/3
250 V, 6.3 A U
IN 6.3 A
250 V, 6.3 A 2​ Terminal block width 6.2 mm / 0.244 in​
L 10 — 12 mm / 0.43 in​
Item no.​
Pack. unit​​
2-conductor fuse terminal block with end plate,
without blown fuse indication​
gray​
2002-1611
50
2-conductor fuse terminal block with end plate,
with blown fuse indication​by LED
gray 12 — 30 V gray 30 — 65 V gray 110 — 250 V 2002-1611/1000-541​
2002-1611/1000-542​
2002-1611/1000-836
Accessories
50
50
50
Item no.​
______>
<_______ 87.5mm /3.45in​ _______>
Pack. unit​​
Item no.​
Pack. unit​​
2-conductor fuse terminal block with end plate,
with additional jumper position,
without blown fuse indication​
gray​
2002-1911
50
4-conductor fuse terminal block with end plate,
without blown fuse indication
2-conductor fuse terminal block with end plate,
with blown fuse indication​by LED
4-conductor fuse terminal block with end plate,
with blown fuse indication by LED
gray 12 — 30 V gray 30 — 65 V
gray 110 — 250 V 2002-1911/1000-541​
2002-1911/1000-542​
2002-1911/1000-836
50
50
50
gray​
gray 12 - 30 V gray 30 - 65 V gray 110 - 250 V
2002-1811​
2002-1811/1000-541​
2002-1811/1000-542​
2002-1811/1000-836​
50
50
50
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End plate for fuse terminal blocks, 2 mm/0.079 in thick​ Protective warning marker, with high voltage symbol, black,​
for 5 terminal blocks​
gray​
2002-991 100 (4x25) yellow​ 2002-115100 (4 x 25)
orange​ 2002-992 100 (4x25) must be applied individually
Insulation stop, 5 pcs/strip​
200 strips​ Push-in type jumper bars, light gray, insulated, IN 25 A​
2-way​ 2004-402200 (8 x 25)
light gray​ 2002-171 0.25-0.5 mm2​ 3-way​ 2004-403200 (8 x 25)
dark gray​ 2002-172 0.75-1 mm2​ 4-way​ 2004-404200 (8 x 25)
must be applied individually
5-way​ 2004-405100 (4 x 25)
:​
:​
10-way​ 2004-410100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​
1 - 3​
2004-433200 (8 x 25)
1 - 4​
2004-434200 (8 x 25)
1 - 5​
2004-435100 (4 x 25)
:​
:​
1 - 10​ 2004-440100 (4 x 25)
50
<_____
<_____
<_______ 72.9mm /2.87in​ _______>
57.2mm /2.26 in​
57.2mm /2.26 in​
<_____ 57.2mm /2.26in​ _____>
<_______ 66.5mm /2.62in​ _______>
0.25 — 2.5 (4) mm2​ AWG 22 — 12​
250 V/6 kV/3 250 V, 6.3 A U
6.3 A​ 250 V, 6.3 A 2
Terminal block width 6.2 mm / 0.244 in​
L 10 — 12 mm / 0.43 in​
______>
0.25 — 2.5 (4) mm2​ AWG 22 — 12​
250 V/6 kV/3 250 V, 6.3 A U
6.3 A​ 250 V, 6.3 A 2
Terminal block width 6.2 mm / 0.244 in​
L 10 — 12 mm / 0.43 in​
WMB Multi Marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-55015
WMB Multi Marking system, plain
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
yellow
793-5501/000-002
red
793-5501/000-005
blue
793-5501/000-006
gray
793-5501/000-007
orange
793-5501/000-012
light green 793-5501/000-017
green
793-5501/000-023
violet
793-5501/000-024
5
WMB Inline, plain
stretchable 5 - 5.2 mm
1,500 WMB markers, 5mm, on roll
white
2009-1151
!1
101
WG 22 - 12
1
57,2 mm/2.25 in
mm / 0.244 in
3 in 3
1 Conductor sizes: 0.25 mm¤ o 4 mm¤ is + f-stw;
Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw
and 0.75 mm¤ o 2.5 mm¤
iinsulated ferrule, 12 mmw
Fuse terminal blocks with a width of 6.2 mm/0.244 in can
be assembled adjacently. If there is no adjacent fuse terminal block at the end of the assembly, an end plate must
be used.
2 250 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(also see Section 14)
3 Strip length, see packaging or instructions.
4 See application notes for:
Push-in type wire jumper, page 140
44 in
o.
Pack.
Unit
erminal block with
mm,
D, gray
e given by the LED or fuse.
n fuse: LED 2 mA
811/1000-541
50
811/1000-542
50
811/1000-836
50
811/1000-867
50
When selecting miniature metric fuses, the maximum
power loss listed below should not be exceeded. The
power loss is determined according to IEC or EN 609477-3/VDE 0611-6 at 23¡C. The temperature rise of the terminal blocks must be checked according to their application and mounting. Higher ambient temperatures place
additional strain on fuse cartridges. Therefore, in such
applications, the rated current must be reduced if necessary. More details available from the manufacturer.
Pivoting the fuse holder in the locked open position.
Miniature metric fuses 5 x 20​
Miniature metric fuses
5 x 20
Overload
and
Series
short circuit protection​
Item No.​
Series
Item No.
Overload and
short
circuit protection
Individual
Group
Short circuit
protection only​
Short circuit
protection
only
Individual
Group
arrangement​Group
arrangement​
arrangement​
Individual
Individual
Grouparrangement​
argmt.
argmt.
argmt.
argmt.
Fuse terminal blocks​
Fuse terminal blocks
2002-1611
2002-1611
2002-1811
Exchanging fuse.
1.6 W​2.5 W 2.5 W​
1.61.6
W W​ 1.6 W
2.5 W
2002-1811​
2002-1611/....-....
2002-1911
1.6 W
1.6 W
2.5 W
2.5 W
2002-1811/....-....
1.6 W​
1.6 W​
2.5 W​
2002-1811/....-....
2002-1611/....-....​
Protective
warning marker and insulation stop must be
2002-1911/....-....
2.5 W​
2.5 W​
applied individually. Due to the 6.2 mm/0.244 in width of
the fuse terminal blocks with pivoting fuse holder, 2004
Protective
warning
Series jumpers
must bemarker
used. and insulation stop
must be singularized.
Due to the 6.2 mm/0.244 in width of the
fuse terminal blocks with pivotable fuse holder,
2004 Series jumpers must be used.​
51
?
TOPJOB¥@
2004 Fuse
Fuse Plugs
Plugs
1 Series
2004 Series
on
2002
Series
Carrier
TerminalBlocks
Blocks
114 on 2002 Series Carrier Terminal
Fuse plug with pull-tab
for miniature metric fuses 5 x 20 mm
250 V / IN 6.3 A
Plug width 6.1 mm / 0.24 in
Fuse plug with pull-tab
for miniature metric fuses 5 x 20 mm
250 V / IN 6.3 A
Plug width 6.1 mm / 0.24 in
Circuit I
Circuit I
009\097\00099798_0.eps
009\097\00099803_0.eps
Item No.
Pack.
Unit
Fuse plug with pull-tab,
for miniature metric fuses 5 x 20 mm
Nominal voltage and current are given by the fuse.
Ǔ
gray
2004-911
50
Accessories
Item No.
Ǔ
Ǔ
Ǔ
Ǔ
Pack.
Unit
Fuse plug with pull-tab,
for miniature metric fuses 5 x 20 mm,
with indicator lamp, gray
Nominal voltage and current are given by the LED or fuse.
Leakage current in case of blown fuse: LED 2 mA
12 - 30 V
2004-911/1000-541
50
30 - 65 V
2004-911/1000-542
50
120 V
2004-911/1000-867
50
230 V
2004-911/1000-836
50
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
WMB Multi marking system, plain,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
yellow
793-5501/000-002
red
793-5501/000-005
blue
793-5501/000-006
gray
793-5501/000-007
orange
793-5501/000-012
light green
793-5501/000-017
green
793-5501/000-023
violet
793-5501/000-024
Accessories
Appropriate marking systems:
WMB/Marking
strips systems: WMB/Marking Strips (see pages 96 -101)
Accessories
Appropriate
marking
(see Section 13)
2-conductor carrier terminal block,
Double-deck carrier terminal block,
1
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
Terminal block width 5.2 mm / 0.205 in
Terminal block width 5.2 mm / 0.205 in
gray
2002-1661
50
L/L
2002-2961
50
End and intermediate plate, 1 mm thick
Double-deck carrier terminal block,
orange
2002-1692 100 (4x25)
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
gray
2002-1691 100 (4x25)
Terminal block width 5.2 mm / 0.205 in
L/N
2002-2963
50
End and intermediate plate, 1 mm thick
4-conductor carrier terminal block,
2
orange
2002-2992 100 (4x25)
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
gray
2002-2991 100 (4x25)
Terminal block width 5.2 mm / 0.205 in
gray
2002-1861
50
End and intermediate plate, 1 mm thick
End plate for fuse terminal blocks,
orange
2002-1892 100 (4x25)
2 mm thick
gray
2002-1891 100 (4x25)
orange
2002-992 100 (4x25)
gray
2002-991 100 (4x25)
2-conductor carrier terminal block,
Shorting link, 5 x 20 mm,
3
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
if the fuse plug is used as disconnect plug
IN 6.3 A
Terminal block width 5.2 mm / 0.205 in
281-503 250 (10x25)
gray
2002-1961
50
Disconnect Plug,
End and intermediate plate, 1 mm thick
orange 2002-401 100 (4x25)
orange
2002-1992 100 (4x25) gray
2002-1991 100 (4x25)
Component Plug
gray
2002-8xx
See pages 67 - 69
For list of approvals and user guide, see pages 634 to 637.
52
Double-deck carrier terminal block,
0.25 - 2.5 (4) mm2/AWG 22-12
L/L
2002-2661
N/L
2002-2662
PE/L
2002-2667
End and Intermediate Plate, 1mm thick
orange
2002-2692
gray
2001-2691
5
5
5
5
5
5
5
5
5
5
Technical Information
71 mm/2.79 in 4
1 2 3
Fuse plug dimensions:
1 66.5 mm/2.62 in for 2002-1661
2 87.5 mm/3.45 in for 2002-1861
3 72.9 mm/2.87 in for 2002-1961
4 with inserted fuse plug
Using pluggable fuse holders with rail-mount terminal
blocks for control circuit protection is highly advantageous
for the user since the function and the wiring are accomplished by two separate parts:
r No additional cost for assembly and wiring
r No risk of accidental contact with live parts during
disconnection of fuse plug
r If exchanging a defective fuse, the fuse plug is
completely separated from the carrier terminal block.
This provides safe fuse changeout away from current
carrying parts.
r The fuse plug can be removed by service personnel,
avoiding unintentional reclosing of the circuit by another
person.
r Quick replacement a fuse by using a prepared istandby plug.i
Miniature metric fuses 5 x 20
Series
Item No.
Overload and
short circuit protection
Individual
argmt.
Group
argmt.
Short circuit
protection only
Individual
argmt.
Group
argmt.
Fuse terminal blocks
2004-911
2004-911/....-....
1.6 W
1.6 W
2.5 W
2.5 W
The following fuse plug features provide quick and safe
handling:
r Optional LED indicates blown fuse
r Marking slot on the fuse plug for clear coordination to
the correct carrier terminal block
r Two touch-proof test slots
r High density with only 6.1 mm/0.24 in width of
terminal block/fuse plug
r Instead of a fuse, a shorting link may be used as a
disconnect plug.
0,9
5,2
N L1 N L2 N L3
Open side of terminal block left
Please note:
The extra width of the plug (6.1 mm/0.24 in compared to
5.2 mm/0.2 in for carrier terminal blocks) must be compensated for by intermediate plates (1 mm/0.039 in)
when building an assembly of carrier terminal blocks
equipped with fuse plugs.
53
?
Double-Deck Disconnect Terminal Blocks and Carrier Terminal Blocks
2.5 (4) mm²/AWG 12, 2002 Series
0.25 - 2.5 (4)
400 V/6 kV/3
IN 16 A
mm²
0.25 - 2.5 (4)
400 V/6 kV/3
IN 16 A
AWG 22 - 12
AWG 22 - 12
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
51,7 mm/2.04 in
51,7 mm/2.04 in
56,4 mm/2.22 in
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
mm²
93 mm/3.66 in
Item No.
93 mm/3.66 in
Pack.
Unit
Item No.
Double-deck carrier terminal block,
upper deck carrier,
gray housing
L/L
2002-2661
N/L
2002-2662
50
50
51,7 mm/2.04 in
Double-deck disconnect terminal block,
with movable knife disconnect,
gray housing
L/L
50
2002-2671
N/L
50
2002-2672
Pack.
Unit
93 mm/3.66 in
Item No.
Double-deck carrier terminal block,
upper deck carrier,
gray housing
PE/L
2002-2667
Accessories
Fuse Plug
gray 2004-911
see page 52
Pack.
Unit
50
50
Disconnect Plug
2002-401 100 (4x25)
orange
Component Plug
gray 2002-8xx
see pages 67-69
54
50
2002 Series Accessories
Appropriate marking systems: WMB/Marking
strips/WMB Inline (See pages 96 -101)
End and intermediate plate,
1 mm thick
orange
2002-2692
gray
2002-2691
Double-deck marker carrier,
pivoting
gray
2002-121
1
1
50 (2x25)
Insulation stop,
5 pcs/strip,
0.25 - 0.5 mm²
light gray
2002-171
Insulation stop,
5 pcs/strip,
0.75 - 1 mm²
dark gray
2002-172
Push-in type jumper bar, insulated,
IN 25 A,
light gray
2-way
2002-402
3-way
2002-403
4-way
2002-404
5-way
2002-405
6-way
2002-406
7-way
2002-407
8-way
2002-408
9-way
2002-409
10-way
2002-410
Push-in type jumper bar, insulated,
IN 25 A,
light gray
from 1 to 3
2002-433
from 1 to 4
2002-434
from 1 to 5
2002-435
from 1 to 6
2002-436
from 1 to 7
2002-437
from 1 to 8
2002-438
from 1 to 9
2002-439
from 1 to 10 2002-440
200
200
200
100
100
100
100
100
100
(8x25)
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
200
200
100
100
100
100
100
100
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
Double-deck vertical jumper, insulated,
IN 24 A
light gray
2002-492
100 (4x25)
200 (8x25)
200 (8x25)
?
Double-Deck Terminal Blocks 2.5 (4) mm²/AWG 12
2002 Series
mm²
0.25 - 2.5 (4)
500 V/6 kV/3
IN 24 A (28 A)
AWG 22 - 12
mm²
AWG 22 - 12
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
51,7 mm/2.04 in
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
93 mm/3.66 in
Item No.
0.25 - 2.5 (4)
500 V/6 kV/3
IN 24 A (28 A)
AWG 22 - 12
51,7 mm/2.04 in
Terminal block width 5.2 mm / 0.205 in
L10 - 12 mm / 0.43 in
mm²
51,7 mm/2.04 in
0.25 - 2.5 (4)
500 V/6 kV/3
IN 24 A (28 A)
93 mm/3.66 in
Pack.
Unit
Item No.
Through/through terminal block,
same profile as double-deck disconnect terminal block
without marker carrier,
gray housing
L/L
50
2002-2601
N/L
50
2002-2602
L/N
50
2002-2603
93 mm/3.66 in
Pack.
Unit
Item No.
Through/through terminal block,
same profile as double-deck disconnect terminal block
without marker carrier,
blue housing
N/N
50
2002-2604
Pack.
Unit
Ground conductor/through terminal block,
same profile as double-deck disconnect terminal block
without marker carrier,
gray housing
PE/N
50
2002-2647
PE/L
50
2002-2657
93 mm/3.66 in
Item No.
93 mm/3.66 in
Pack.
Unit
Item No.
4-conductor through terminal block,
same profile as double-deck disconnect terminal block,
without marker carrier, internal commoning, conductor
entry position colored in violet,
gray housing
L
50
2002-2608
Accessories
51,7 mm/2.04 in
51,7 mm/2.04 in
51,7 mm/2.04 in
Other terminal blocks with the same profile:
Carrier
2002-2661
Disconnect
2002-2671
93 mm/3.66 in
Pack.
Unit
4-conductor through terminal block,
same profile as double-deck disconnect terminal block,
without marker carrier, internal commoning, conductor
entry position colored in violet,
blue housing
N
50
2002-2609
Item No.
Pack.
Unit
Through/through terminal block,
same profile as double-deck disconnect terminal block
without marker carrier, internal commoning,
green-yellow housing
PE
2002-2607
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate
1 mm thick
orange 2002-2692 1
gray
2002-26911
Double-deck marker carrier
pivoting
gray 2002-121
50 (2 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​
2-way​ 2002-402200 (8 x 25)
3-way​ 2002-403200 (8 x 25)
4-way​ 2002-404200 (8 x 25)
5-way​ 2002-405100 (4 x 25)
:​
:​
10-way​ 2002-410100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A​
1 - 3​
2002-433200 (8 x 25)
1 - 4​
2002-434200 (8 x 25)
1 - 5​
2002-435100 (4 x 25)
:​
:​
1 - 10​ 2002-440100 (4 x 25)
Double-deck vertical jumper, insulated,
IN 24 A​
light gray2002-492 100 (4 x 25)
55
?
Double-Deck Fuse Disconnect Terminal Blocks with Pivoting Fuse Holder 2.5
(4) mm²/AWG 12, 2002 Series
0.25 - 2.5 (4)
400 V/6 kV/3
IN 16 A
mm²
0.25 - 2.5 (4)
400 V/6 kV/3
IN 16 A
AWG 22 - 12
76,4 mm/3.01 in
Terminal block width 6.2 mm / 0.244 in
L10 - 12 mm / 0.43 in
93 mm/3.66 in
Item No.
93 mm/3.66 in
Pack.
Unit
Double-deck fuse disconnect terminal block with
pivoting fuse holder,
Through/fuse terminal block,
for miniature metric fuses 5 x 20 mm,
without blown fuse indication
Nominal voltage and current are given by the fuse.
L/L
N/L
2002-2611
2002-2612
AWG 22 - 12
76,4 mm/3.01 in
Terminal block width 6.2 mm / 0.244 in
L10 - 12 mm / 0.43 in
mm²
Item No.
Double-deck fuse disconnect terminal block with
pivoting fuse holder,
Through/fuse terminal block,
for miniature metric fuses 5 x 20 mm,
with blown fuse indication by LED, gray
Nominal voltage and current are given by the LED or fuse.
Leakage current in case of blown fuse: LED 2mA
12 - 30 V
30 - 65 V
230 V
25
25
Pack.
Unit
2002-2611/1000-541
2002-2611/1000-542
2002-2611/1000-836
25
25
25
Protective warning marker and insulation stop must be
applied individually. Due to the 6.2 mm/0.244 in width of
the fuse terminal blocks with pivoting fuse holder, 2004
Series jumpers must be used.
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate,
1 mm thick
Included with above blocks
Push-in type jumper bar, insulated,
IN 32 A,
light gray
2-way
2004-402
3-way
2004-403
4-way
2004-404
5-way
2004-405
6-way
2004-406
7-way
2004-407
8-way
2004-408
9-way
2004-409
10-way
2004-410
Push-in type jumper bar, insulated,
IN 32 A,
light gray
from 1 to 3
2004-433
from 1 to 4
2004-434
from 1 to 5
2004-435
from 1 to 6
2004-436
from 1 to 7
2004-437
from 1 to 8
2004-438
from 1 to 9
2004-439
from 1 to 10 2004-440
56
200
200
100
100
100
100
100
100
100
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
200
200
100
100
100
100
100
100
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
End plate for fuse terminal blocks,
2 mm thick
orange
2002-1092 100 (4x25)
gray
2002-1091 100 (4x25)
Insulation stop,
5 pcs/strip,
0.25 - 0.5 mm²
light gray
2002-171 200 (8x25)
Insulation stop,
5 pcs/strip,
0.75 - 1 mm²
dark gray
2002-172 200 (8x25) Pivoting the fuse holder in the locked open position.
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2002-115 100 (4x25)
Marking strip, plain,
11 mm wide,
50 m roll
white
1
2009-110
Double-deck vertical jumper, insulated,
IN 24 A
light gray
2002-492 100 (4x25)
Fuse replacement
?
Disconnect Terminal Blocks for Test and Measurement, 6 mm²/AWG 8,
for Current and Voltage Transformer Circuits, 2007 Series
0.5 - 6 (10) mm²
500 V/6 kV/3
IN 30 A
AWG 20 - 8
99,6 mm/3.92 in
Item No.
AWG 20 - 8
Terminal block width 8 mm / 0.315 in
L 13 - 15 mm / 0.55 in
65,3 mm/2.57 in
Terminal block width 8 mm / 0.315 in
L 13 - 15 mm / 0.55 in
65,3 mm/2.57 in
Terminal block width 8 mm / 0.315 in
L 13 - 15 mm / 0.55 in
0.5 - 6 (10) mm²
500 V/6 kV/3
IN 30 A
AWG 20 - 8
46,8 mm/1.85 in
0.5 - 6 (10) mm²
500 V/6 kV/3
IN 30 A
99,6 mm/3.92 in
Pack.
Unit
Item No.
2-conductor disconnect terminal block for test and
measurement, e.g., current and voltage transformer
circuits, with touch-proof test sockets,
for 4 mm Ø test plug
gray
20
2007-8821
99,6 mm/3.93 in
Pack.
Unit
Item No.
2-conductor disconnect terminal block,
with touch-proof test sockets,
for 4 mm Ø test plug
gray
2007-8811
2-conductor through terminal block,
with touch-proof test socket,
for 4 mm Ø test plug
gray
2007-8801
2-conductor ground terminal block,
with touch-proof test socket,
for 4 mm Ø test plug
20
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
green yellow
End and separator plate, 1.5 mm thick,
without use of lock-out seal
orange
2007-8892
gray
2007-8891
End and separator plate, 1.5 mm thick,
for use of lock-out seal
orange
2007-8894
gray
2007-8893
Lock-out,
for disconnect link
yellow
2007-8899
Locking cover, transparent,
mechanically locks multiple links
1-pole
50
282-881
2-pole
50
282-882
3-pole
50
282-883
4-pole
50
282-884
5-pole
50
282-885
6-pole
50
282-886
7-pole
50
282-887
8-pole
50
282-888
1
1
1
1
Pack.
Unit
Adjacent jumper for switch lever, insulated, orange,
IN 30 A
2-way
2007-8442
3-way
2007-8443
4-way
2007-8444
5-way
2007-8445
6-way
2007-8446
7-way
2007-8447
8-way
2007-8448
2007-8807
20
20
1
1
1
1
1
1
1
1
(5x10)
(5x10)
(5x10)
(5x10)
(5x10)
(5x10)
(5x10)
(5x10)
Jumper, insulated,
IN 30 A,
orange
2-way
50 (5x10)
282-432
3-way
50 (5x10)
282-433
4-way
50 (5x10)
282-434
5-way
50 (5x10)
282-435
6-way
50 (5x10)
282-436
7-way
50 (5x10)
282-437
8-way
50 (5x10)
282-438
9-way
50 (5x10)
282-439
10-way
50 (5x10)
282-440
Jumper with safety lid, insulated,
IN 30 A,
orange
2-way
282-432/100-000
3-way
282-433/100-000
4-way
282-434/100-000
50 (5x10)
Interlocking link,
mechanically locks multiple links,
1 m/3’3’’ long
transparent
1
210-254
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2006-115 100 (4x25)
Jumper, special design,
WMB Multi marking system
IN 30 A,
10 strips with 10 markers per card,
orange
for terminal widths 5 - 17.5 mm
1-3-5
plain
793-501
5
1-3-5-7
Marking strip, plain,
11 mm wide,
50 m roll
white
2009-110
1
Integrated test sockets for touchproof 4 mm Ø test plugs.
Lock-out prevents accidental operation of disconnect link.
282-435/011-000
282-437/011-000
50 (5x10)
57
?
Disconnect and Ground Conductor Terminal Blocks, 6mm2/AWG 8
6 (10) mm2/30 A and Through Terminal Blocks of Same Profile, 2006 Series
0.5 — 6 (10) mm2​
800 V/6 kV/3 ➊
IN 30 A​
AWG 20 — 8​
600 V, 30 A, U
600 V, 30 A, 2
Terminal block width 7.5 mm / 0.295 in​
L 13 — 15 mm / 0.55 in​
<38,2 mm /1.50 in >
​
<______________ 96,3 mm/3.79 in​_______________>
25
25
AWG 20 — 8​
600 V, 30 A, 2
Terminal block width 15 mm / 0.59 in​
L 13 — 15 mm / 0.55 in​
<38,2 mm/1.50 in >
​
<______________ 96,3 mm /3.79 in​_______________>
Description​
2-conductor disconnect terminal blocks,
with testing facility,
disconnect link orange
gray​
2006-1671
blue​
2006-1674
0.5 — 6 (10) mm2​
500 V/6 kV/3 ➊
IN 30 A​
mm /​
<__ 32,9
1.29 in​ __>
<_ 37 mm /1.46 in​ _>
<___ 49 mm /1.93 in​___>
Terminal block width 7.5 mm / 0.295 in​
L 13 — 15 mm / 0.55 in​
AWG 20 — 8​
600 V, 30 A, U
600 V, 30 A, 2
mm /​
<__ 32,9
1.29 in​ __>
0.5 — 6 (10) mm2​
800 V/6 kV/3 ➊
IN 30 A​
Item no.​
Pack. unit​​
2-conductor through terminal blocks,
with testing facility,
of same shape as disconnect terminal blocks at the left​
gray​
2006-1601
25
blue​
2006-1604
25
<38,2 mm /1.50 in >
​
<______________ 96,3 mm /3.79 in​_______________>
Item no.​
Ground cond. disconnect term. block, gray​
24 V​
2006-1671/1000-0848
48 V​
2006-1671/1000-0849
120 V​
2006-1671/1000-0850
30 V​
2006-1671/1000-0851
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
2-conductor disconnect end plates, 1 mm/0.039 in thick​
orange​ 2006-1692100 (4 x 25)
gray​
2006-1691100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 41 A​
2-way​ 2006-402 50 (2 x 25)
3-way​ 2006-403 50 (2 x 25)
4-way​ 2006-404 50 (2 x 25)
5-way​ 2006-405 50 (2 x 25)
Protective warning marker, with high voltage symbol, black,​
for 5 terminal blocks​
yellow​ 2006-115 100 (4 x 25)
Double-deck marker carrier,
pivoting
gray
2002-121
50 ( 2 x25)
H 2​
LED/Neon lamp​
green​
T 1​
Push-in type jumper bars, light gray, insulated, IN 41 A​
1 - 3​
1 - 4​
1 - 5​
2006-433 50 (2 x 25)
2006-434 50 (2 x 25)
2006-435 50 (2 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
H 1​
LED/Neon lamp​​
red
K 2​
K1​
Operating condition
slide link closed, auxiliary circuit grounded,
green lamp illuminates.​
H 2​
LED/Neon lamp​
green
Start point jumper, insulated,
WMB Multi marking system,
10 strips with 10 markers per card,
IN = IN terminal block, light gray​
for 5-5.2 mm terminal block width
1-3-5​
2006-405/011/000
plain
793-5501 5
50 (2 x 25) T 1​
H 1​
LED/Neon lamp​
red
K 2​
K1​
Test condition – no grounding
slide link open, auxiliary circuit not grounded.​
H 2​
LED/Neon lamp​
green
T 1​
H 1​
LED/Neon lamp​
red
K 2​
K1​
Fault condition – grounding
slide link open, auxiliary circuit not grounded,
red lamp illuminates.​
58
Pack. unit​​
12​
12​
12​
12​
?
Disconnect Terminal Blocks for Test and Measurement 1500 VDC,
Carrier/Through Terminal Blocks, 2006 Series (15mm width)
0.5 - 6 (10) mm²
AWG 20 - 8
AC/DC 1000 V/ DC 1500 V/12 kV/3
IN 30 A
Terminal block width 15 mm / 0.591 in
L 13 - 15 mm / 0.55 in
Terminal block width 15 mm / 0.591 in
L 13 - 15 mm / 0.55 in
Terminal block width 15 mm / 0.591 in
L 13 - 15 mm / 0.55 in
33 mm/1.3 in
106,9 mm/4.21 in
Item No.
33 mm/1.3 in
0.5 - 6 (10) mm²
AWG 20 - 8
AC/DC 1000 V/ DC 1500 V/12 kV/3
IN 30 A
59,2 mm/2.33 in
0.5 - 6 (10) mm²
AWG 20 - 8
AC/DC 1000 V/ DC 1500 V/12 kV/3
IN 30 A
106,9 mm/4.21 in
Pack.
Unit
Item No.
106,9 mm/4.21 in
Pack.
Unit
Item No.
2-conductor disconnect terminal block for test and
measurement,
with test point,
orange disconnect link
gray
12
2006-8671
blue
12
2006-8674
2-conductor carrier terminal block,
with test point
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
gray
blue
2006-8661
2006-8664
Pack.
Unit
2-conductor through terminal block,
with test point,
same profile as 2-conductor disconnect terminal block
12
12
gray
blue
2006-8601
2006-8604
12
12
WMB Multi marking system,
End and intermediate plate,
WMB Multi marking system,
10 strips with 10 markers per card,
1 mm thick
10 strips with 10 markers per card,
orange
1
stretchable 5 - 5.2 mm
2006-8692
for terminal widths 5 - 17.5 mm
plain
gray
1
plain
5
793-5501
793-501
2006-8691
WMB Inline, plain,
Marking strip, plain,
Protective warning marker,
stretchable 5 - 5.2 mm,
11 mm wide,
with high-voltage symbol, black,
1,500 WMB markers, 5 mm, on roll
50 m roll
for 5 terminal blocks
white
white
1
2009-115
2009-110
yellow
2006-115 100 (4x25)
Push-in type jumper bar, insulated,
Disconnect plug
IN 41 A,
orange
2006-8401 48 (4x12)
light gray
from 1 to 2
50 (2x25)
2006-433
from 1 to 3
50 (2x25)
2006-435
Lockout cap,
for conductor entry hole and operating
slot
gray
25
2006-191
5
1
59
?
TOPJOB¥@
/AWG 8
Fuse
Terminal
Blocks
forfor
Automotive
Blade-Type
FusesFuses
6 (10)6 (10)
mm2mm¤
1 Fuse
Terminal
Blocks
Mini-Automotive
Blade-Style
2006​
Series
Series
110 2006
1 AWG 20 - 8
0.5 - 6 (10) mm¤
0.5 —500
6 (10)
mm22​ AWG 20 — 8​
V/8 kV/3
500 V/8 kV/3
12 V, 30 A, U
N 25 A (30 A) 3
IN 25 IA
(30 A)
600 V, 30 A 2
0.5 - 6 (10) mm¤ 2​AWG 20 - 8
0.5
— 6 (10) 2mm AWG 20 — 8​
500 V/8
V/8 kV/3
500
kV/3
24 V, 30 A, U
25 A
A (30
ININ25
(30A)
A)3
600 V, 30 A 2
1
38,2 mm/1.5 in
Circuit I
Circuit II
Circuit I
32,9 mm/1.29 in
37,9mm/1.49 in
Terminal
blockblock
width width
7.5 mm7.5
/ 0.295
Terminal
mm in
/ 0.295 in​
13 - 1513
mm—/ 15
0.55
in 4
L
L
mm
/ 0.55 in​
32,9 mm/1.29 in
37,9mm/1.49 in
38,2 mm/1.5 in
96,3 mm/3.79 in
Terminal block
mmmm
/ 0.295
in in​
Terminal
blockwidth
width7.57.5
/ 0.295
- 15
/ 0.55
in 4 in​
L 1313
L
— mm
15 mm
/ 0.55
32,9 mm/1.29 in
37,9mm/1.49 in
Terminal block width 7.5 mm / 0.295 in
Terminal
block width 7.5 mm / 0.295 in​
L 13 - 15 mm / 0.55 in 4
L
13 — 15 mm / 0.55 in​
0.5 - 6 (10) mm¤ 1 AWG
-8
0.5 — 6 (10) mm2​ 20AWG
20 — 8​
2
500500
V/8 kV/3
V/8 kV/3
48 V, 30 A, U
3 A)
IN 25INA25
(30AA)(30
600 V, 30 A 2
38,2 mm/1.5 in
96,3 mm/3.79 in
Circuit II
Circuit I
96,3 mm/3.79 in
Circuit II
Pack.
Pack.
Pack.
Item No.
Item No.
Unit
Unit
Unit
2-conductor fuse terminal block for automotive
mini-automotive
2-conductor fuse terminal block for automotive
mini-automotive
2-conductor fuse terminal block for automotive
mini-automotive
Item No.
Ǔ
Ǔ
blade-style fuses,
12V, with test point, with blown fuse indication by LED,
LED power consumption: 4.8 mA, gray
Nominal voltage and current are given by the LED or fuse.
Blade-style fuses, please note touchproof protection for
42V and higher.
Circuit I
2006-1681/1000-429
25
Circuit II
2006-1681/1000-449
25
Ǔ
Other terminal blocks with the same profile:
50
Through
2006-1601
PageǓ108
Ǔ
Ǔ
blade-style fuses,
24V, with test point, with blown fuse indication by LED,
LED power consumption: 4.8 mA, gray
Nominal voltage and current are given by the LED or fuse.
Blade-style fuses, please note touchproof protection for
42V and higher.
Circuit I
2006-1681/1000-413
25
Circuit II
2006-1681/1000-434
25
Ǔ
Ǔ
blade-style fuses,
48V, with test point, with blown fuse indication by LED,
LED power consumption: 4.8 mA, gray
Nominal voltage and current are given by the LED or fuse.
Blade-style fuses, please note touchproof protection for
42V and higher.
Circuit I
2006-1681/1000-414
25
Circuit II
2006-1681/1000-435
25
2006 Series Accessories
Accessories
Appropriate
marking
systems:
WMB/Marking
strips Strips (see pages 96 -101)
Appropriate
marking
systems:
WMB/Marking
(see Section 13)
End and intermediate plate, 1 mm thick
orange
2006-1692 100 (4x25)
gray
2006-1691 100 (4x25)
Push-in type jumper bar, insulated,
IN 41 A,
light gray
2-way
2006-402
3-way
2006-403
4-way
2006-404
5-way
2006-405
50
50
50
50
Push-in type jumper bar, insulated,
IN 41 A,
light gray
from 1 to 3
2006-433
from 1 to 4
2006-434
from 1 to 5
2006-435
50 (2x25)
50 (2x25)
50 (2x25)
(2x25)
(2x25)
(2x25)
(2x25)
For list of approvals and user guide, see pages 634 to 637.
60
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2006-115 100 (4x25)
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
Marking strip, plain,
11 mm wide,
50 m roll
white
2009-110
1
Double-deck marker carrier,
pivoting
gray
2002-121
50 (2x25)
End and Intermediate Plate, 2.9 mm thick
orange​ 2006-1696100 (4 x 25)
gray
2006-1695100 (4 x 25)
Note: Use thicker end plate when using ETA breakers
rather than fuses
!1
? Current-Carrying Capacity Curves​
111
Terminal
width
7.57.5
mmmm
/ 0.295
in
Terminalblock
block
width
/ 0.295
in​
4 in​
- 15—mm
0.55/in0.55
L
L13 13
15/mm
Irat — Displacement %
40
20
10
0
-10
-20
-30
23°C
-40
-20
0
20
40
60
1 Conductor sizes: 0.5 mm¤ o 10 mm¤ is + f-stw;
Push-in conductor sizes: 1 mm¤ o 10 mm¤ isw
and 1.5 mm¤ o 6 mm¤
iinsulated ferrule, 12 mmw
32,9 mm/1.29 in
37,9mm/1.49 in
38,2 mm/1.5 in
1
30
Ambient temperature °C
AWG
1 2​
6 (10)
mm¤
0.5
AWG
20 - 820 — 8​
0.5 - —
6 (10)
mm
500
500V/8
V/8kV/3
kV/32
600 V, 30 A, U
3
INN 25
25AA(30
(30A)A)
600 V, 30 A 2
2 500 V = rated voltage
8 kV = rated surge voltage
3 = pollution degree
(also see Section 14)
3 LED power consumption: 4.8 mA
96,3 mm/3.79 in
4 Strip length, see packaging or instructions.
Current-carrying capacity
[A]
Ǔ
Pack.
Item No.
Unit
2-conductor fuse terminal block for mini-automotive
automotive
blade-style fuses,
with test point,
without blown fuse indication
Nominal voltage and current are given by the fuse. Bladestyle fuses, please note touchproof protection for 42V and
higher.
gray
2006-1681
25
Blade-style fuses
(not offered by WAGO)
Excess-current circuit-breaker, thermal
(not offered by WAGO)
Recommended excess-current circuit-breakers from
ETA
Blade-type fuse cartridges,​
acc. to DIN 72581-3c/ISO 8820​
(contact WAGO)
Over-current circuit-breaker,​
thermal,​
(contact WAGO)
Requires the use of an end plate
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
Commning
It
4
Fuse ... A
/ Cross section ... mm²
Individual arrangement
3
2
1
2
3
4
10 A / 2.5 mm²
15 A / 2.5 mm²
20 A / 2.5 mm²
30 A / 4 mm²
1
0
10
20
30
85
75
65
55
Temperature rise
40 45 50 Δ T [K]
Ambient operating
45 40 35 temperature [°C]
Diagram: Individual arrangement
The rated currents of the fuse cartridges are defined differently in international standards. Due to the different current
rating definitions, the recommended current-carrying permanent capacity of the fuses is max. 80% of their rated
current according to DIN 72581 part 3 (for an ambient
operating temperature of 23¡C).
Selecting the correct fuse cartridge is important for product
safety within applications, as well as for fuse cartridge service life and reliability. Fuse cartridges may be used as
protection (break-off point) if they are properly selected
and used according to manufacturer specifications.
Current-carry capacity
[A]
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
Commoning
It
Fuse ... A
/ Cross section ... mm²
4
In a group
1
2
3
4
3
2
10 A / 2.5 mm²
15 A / 2.5 mm²
20 A / 4 mm²
25 A / 4 mm²
1
0
10
20
30
85
75
65
55
Temperature rise
40 45 50 Δ T [K]
Ambient operating
45 40 35 temperature [°C]
Diagram: Block arrangement
Information from the mini-automotive
blade-type fuse manufacturers
FT
%
Derating
Tamb /°C
– 25
14
0.877
– 20
13
0.885
– 15
12
0.893
– 10
11
0.901
– 5
10
0.909
0
9
0.917
5
8
0.926
10
6
0.943
15
4
0.962
20
2
0.980
23
0
1.000
30
– 2
1.020
35
– 4
1.042
40
– 6
1.064
45
– 8
1.087
50
– 10
1.111
55
– 13
1.149
60
– 16
1.190
65
– 19
1.235
70
– 22
1.282
Regarding product safety, it is in generally necessary to
test fuse cartridges under normal conditions and operational failures within your application.
61
1
Fuse Disconnect Terminal Blocks with Pivoting Fuse Holder
for Miniature Metric Fuses 5 x 20 mm, 5 x 30 mm, ž" x1ž", 2006 Series
112
!
!
¥
?
800
V/8 kV/3 2 @ 600 V, 15 AU
800 V/8 kV/3 2
TOPJOB
I
10
A
I 10 A
Disconnect
Terminal
Blocks
withPivoting
PivotingFuse
Fuse
Holder,
1 Fuse
Fuse Disconnect Terminal Blocks
with
Holder
Terminal block width 7.5 mm / 0.295 in
Terminal block width 7.5 mm / 0.295 in
Miniature
Metric
Fuses55
20
mm,/ 0.55
5x x
30 mm, 1⁄4" x 1 1⁄4", 2006​Series
for
Miniature
Metric
Fuses
xx20
30
112 for
13 - 15¥mm / 0.55
in 3
13mm,
- 15 mm5
in 3 mm, ž" x1ž", 2006 Series
L
L
0.5 - 6
TOPJOB @1
0.5 - 6 (10) mm¤ 2​AWG
0.5 - 6 (10) mm¤ 1 2​AWG
20 - 8
20 - 8
AWG
AWG
Fuse
Disconnect
Blocks
with
Pivoting
Fuse
0.5 —
0.5 —
(10)2mm 600
(10)2mm
20
20
— 8​ Holder
800
V/86kV/3
800
V/86kV/3
V, Terminal
15 A
U— 8​
600 V, 15 A U
600 V, 15 A U
I800
10 V/8
A kV/3
10 V/8
A kV/3
for
Metric
5I800
30V,mm,
I 10 Miniature
I x
A​
600 V, 15Fuses
A2
1020
A​ mm, 5 x 600
15 A 2ž" x1ž", 2006 Series
N
N
Ǔ
Terminal
block
width
mm / 0.295 in
1 7.5
mm¤
0.5
- 6 (10)
AWG
20 - 8/ 0.295 in​
Terminal
block
width
7.5 mm
mm / 0.55 in 3
L 13 - 15
2
800
V/8 kV/3
600/V,0.55
15 Ain​
U
L
13 — 15 mm
IN 10 A
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
62
N
Terminal block width 7.5 mm / 0.295 in
L 13 - 15 mm / 0.55 in 3
Ǔ
Ǔ
N
Terminal
block
width
mm / 0.295 in
1 7.5
mm¤
0.5
- 6 (10)
AWG
20 - 8/ 0.295 in​
Terminal
block
width
7.5 mm
mm / 0.55 in 3
L 13 - 15
2
800
V/8 kV/3
L
13 — 15 mm / 0.55 in​
IN 10 A
1 Conductor sizes: 0.5 mm¤ o 10 mm¤ is + f-stw;
Push-in conductor sizes: 1 mm¤ o 10 mm¤ isw
and 1.5 mm¤ o 6 mm¤
iinsulated ferrule, 12 mmw
2 800 V = rated voltage
8 kV = rated surge voltage
3 = pollution degree
(see
Sectionsizes:
14) 0.5 mm¤ o 10 mm¤ is + f-stw;
1 Conductor
conductor
sizes: 1 mm¤
o 10 mm¤ isw
Strip length,
see packaging
or instructions.
3 Push-in
and 1.5 mm¤ o 6 mm¤
See application
for:
4 iinsulated
ferrule,notes
12 mmw
96,3 mm/3.79 in
96,3 mm/3.79 in
Star point jumper, page 140
2 800 V = rated voltage
sizes:
0.5 voltage
mm¤ o 10 mm¤ is + f-stw;
1 Conductor
8 kV = rated
surge
Push-in
1 mm¤ o 10 mm¤ isw
Pack.
Pack.
3 =conductor
pollution sizes:
degree
Item No.
Item No.
and
1.5
mm¤
o
6
mm¤
Unit
Unit
(see Section 14)
iinsulated ferrule, 12 mmw
2-conductor fuse disconnect terminal block with
2-conductor fuse disconnect terminal block with
3 Strip length, see packaging or instructions.
2 800 V = rated voltage
pivoting fuse holder,
pivoting fuse holder, gray,
8 kV
= rated surge
application
notesvoltage
for:
4 See
96,3 mm/3.79 in
96,3 mm/3.79
without blown fuse indication
with blown fuse indication
by LEDin
3 = pollution
degree140
Star point
jumper, page
Nominal voltage and current are given by the fuse.
Nominal voltage and current are given by the LED or fuse.
(see Section 14)
Pack.
for miniature metric fuses 5 x 20 mm
Leakage current in case of blown fuse: LED 2 mA, Pack. 3 Strip length, see packaging or instructions.
Item No.
Item No.
Unit
Unit
for miniature metric fuses 5 x 20 mm
4 See application notes for:
96,3 mm/3.79
in
96,3 mm/3.79
in
2-conductor fuse disconnect
terminal
block with
2-conductor fuse disconnect
terminal
block with
Star point jumper, page 140
pivoting
pivoting
fuse
gray fuse holder, 2006-1611
25
12 - 30
V holder, gray,
2006-1611/1000-541
25
Pack.
Pack.
without blown fuse indication
with30
blown
by LED
- 65 fuse
V indication
2006-1611/1000-542
25
Item No.
Item No.
Unit
Nominal voltage and current are given byUnit
the fuse.
Nominal
are given by the LED or25
fuse.
120 Vvoltage and current
2006-1611/1000-867
Pivoting the fuse holder in the locked open position.
for miniature metric
fuses 5 x 20terminal
mm
Leakage
in case
of blown
fuse: LED
2 mA,
230 Vcurrent
2006-1611/1000-836
2-conductor
fuse disconnect
block with
2-conductor
fuse
disconnect
terminal
block
with25
for miniature
fusesgray,
5 x 20 mm
pivoting fuse holder,
pivoting
fusemetric
holder,
for miniature
fuses 5 x 30 mm
for miniature
metric
fuses 5by
x 30
without
blownmetric
fuse indication
with
blown fuse
indication
LEDmm
gray voltage and current
2006-1611
25the fuse.
12 - 30
V
2006-1611/1000-541
2006-1621
2006-1621/1000-541
Nominal
are given by
Nominal
voltage
and current
are given by the LED or25
fuse.
2006-1611/1000-542
30 - 65
V in case 2006-1621/1000-542
for miniature metric fuses 5 x 20 mm
Leakage
current
of blown fuse: LED 2 mA, 25
2006-1611/1000-867
120 V metric fuses2006-1621/1000-867
25
for miniature
5 x 20 mm
Pivoting the fuse holder in the locked open position.
2006-1611/1000-836
230 V
2006-1621/1000-836
25
380- 30
- 500
2006-1621/1000-859
gray
2006-1611
25
12
V V
2006-1611/1000-541
25
for miniature metric fuses 5 x 30 mm
for miniature
5 x 30 mm
30 - 65 Vmetric fuses2006-1611/1000-542
25
gray
12 - 30
2006-1621/1000-541
for miniature
metric fuses2006-1621
1/4" x 11/4" 25
for miniature
1/4" x 11/4"
120
V Vmetric fuses2006-1611/1000-867
25
Pivoting the fuse holder in the locked open position.
30
2006-1621/1000-542
gray
2006-1631
25
12 - 65
30
2006-1631/1000-541
230
V V
2006-1611/1000-836
25
120- 65
V V
2006-1621/1000-867
30
2006-1631/1000-542
25
230 V metric fuses2006-1631/1000-867
2006-1621/1000-836
120
25
for miniature metric fuses 5 x 30 mm
for miniature
5 x 30 mm
380- 30
- 500
2006-1621/1000-859
230
V
2006-1631/1000-836
gray
2006-1621
25
12
V V
2006-1621/1000-541
25
380- 65
- 500
2006-1631/1000-859
30
V V
2006-1621/1000-542
25
for miniature metric fuses 1/4" x 11/4"
for miniature
1/4" x 11/4"
120 V metric fuses2006-1621/1000-867
25
gray Series Accessories
2006-1631
25
12 - 30
2006-1631/1000-541
230
V V
2006-1621/1000-836
25
2006
30 - 65
V V
2006-1631/1000-542
380
- 500
2006-1621/1000-859
25
Appropriate marking systems: WMB/Marking
strips
120 V
2006-1631/1000-867
25
(see Section
13) V metric fuses2006-1631/1000-836
230
25
for miniature metric fuses 1/4" x 11/4"
for miniature
1/4" x 11/4"
380- 30
- 500
V
2006-1631/1000-859
Endgray
and intermediate2006-1631
plate, 1 mm thick
Push-in
type
bar,
insulated,
25
12
V jumper
2006-1631/1000-541
25
Opening the cover to replace the fuse.
orange
2006-1692 100 (4x25)
30 - 65 V IN 41 A,2006-1631/1000-542
25
gray
2006-1691 100 (4x25)
light gray
120 V
2006-1631/1000-867
25
2006
Series
Accessories
Accessories
from 1 2006-1631/1000-836
to 3
230 V
25
Appropriate marking systems: WMB/Marking
strips 2006-433 50 (2x25)
1 2006-1631/1000-859
to 4 96 2006-434
50 (2x25)
End plate for fuse
terminal blocks,
380
- 500
V from
25
Appropriate
marking
systems: WMB/Marking
Strips
(see
pages
-101)
(see Section 13)
from 1 to 5
2006-435
50 (2x25)
2 mm thick
End andSeries
intermediate
plate, 12006-992
mm thick
orange
100 (4x25) Push-in type jumper bar, insulated,
2006
Accessories
Opening the cover to replace the fuse.
orange
2006-1692
IN 41 A,
gray
2006-991 100 (4x25)
Appropriate
marking
systems: WMB/Marking
strips
gray bar, insulated,
2006-1691 100 (4x25) Protective warning
light gray
Push-in type jumper
marker,
(see Section 13)
from
1 to 3
2006-433
IN 41 A,
with high-voltage
symbol, black,50 (2x25)
from
to 4insulated,
2006-434
50 (2x25)
plateintermediate
for fuse
lightterminal
gray
for 5 1terminal
blocks
End and
plate,blocks,
1 mm thick
Push-in type jumper
bar,
from
to 5
2006-435
50 (4x25)
(2x25) Opening the cover to replace the fuse.
2
mm thick
2-way
2006-402 100
50 (4x25)
(2x25)
2006-115 100
orange
2006-1692
Iyellow
N 411A,
orange
2006-992 100
3-way
2006-403
50 (4x25)
(2x25) Test plug,
gray
2006-1691
light gray
gray
2006-991 100
(4x25)
4-way
2006-404
50 (2x25)
with 500
from
1 to mm
3 cable,
2006-433
50 (2x25)
Push-in
type
bar, insulated,
5-way
2006-405
50 (2x25) Protective warning
2 mmmarker,
from
1to 4
2006-434
50 (2x25)
End
plate
forjumper
fuse
terminal
blocks,
41 A,
IN mm
with high-voltage
symbol, black,50 (2x25)
red
210-136
50
from
1 to 5
2006-435
2
thick
lightinsulated,
gray
for 5 terminal
system,blocks
Star point jumper,
orange
2006-992 100 (4x25) WMB Multi marking
4
2006-402
50 (4x25)
(2x25)
yellow
10 strips with 102006-115
markers per 100
card,(4x25)
light gray
I2-way
gray
2006-991
100
N = IN terminal block,
3-way
2006-403
50 (2x25) Protective
Test plug, warning
stretchable
5 - 5.2 mm
1-3-5 bar, insulated,
2006-405/011-000
Push-in type jumper
marker,
2006-404
50 (2x25)
500 mm cable,
plainhigh-voltage
793-5501
5
I4-way
with
symbol, black,
N 41 A,
5-way
2006-405
50 (2x25)
2 mm

light
gray
for
5 terminal
blocks
For list of approvals
and
user guide,
see pages 634
to 637.
red
210-136
50
2-way
2006-402
50 (2x25)
yellow
2006-115
100 (4x25)
WMB
Multi marking system,
Star point jumper,
insulated, 2006-403
3-way
50 (2x25) Test
plug,
4
10 strips
10 markers per card,
light gray50 (2x25)
IN = IN terminal block,
4-way
2006-404
with
500 with
mm cable,
stretchable
1-3-5
2006-405/011-000
5-way
2006-405
50 (2x25)
2
mm  5 - 5.2 mm
50 (2x25)
plain
793-5501
5
red
210-136
50
Starlistpoint
jumper,and
insulated,
For
of approvals
user guide, see pages 634 to 637. WMB Multi marking system,
4
10 strips with 10 markers per card,
IN = IN terminal block, light gray
stretchable 5 - 5.2 mm
1-3-5
2006-405/011-000
50 (2x25)
plain
793-5501
5
Terminal block width 7.5 mm / 0.295 in
L 13 - 15 mm / 0.55 in 3
N
59 mm/2.32 in
(10) mm¤ 1 AWG 20 - 8
59 mm/2.32 in 59 mm/2.32 in
112
N
59 mm/2.32 in
1
0.5 - 6
59 mm/2.32 in 59 mm/2.32 in
(10) mm¤ 1 AWG 20 - 8
?
TOPJOB¥@
Fuse
Blockswith
withPivoting
PivotingFuse
FuseHolder
Holder,
FuseDisconnect
Disconnect Terminal
Terminal Blocks
for
Fuses ž"
¼"xx1ž",
1¼",2006
2006​
Series
forMiniature
Miniature Metric Fuses
Series
0.5 - 6 (10) mm¤ 1 AWG 20 - 8
AWG 20 — 8​
0.5 V/8
— 6kV/3
(10)2mm2​600
800
V, 15 AU
800
V/8
kV/3
600 V, 15 A U
IN 10 A
IN 10 A​
600 V, 15 A 2
0.5 - 6
Terminal block width 10.4 mm / 0.409 in
Terminal block width 10.4 mm / 0.409 in​
L 13 - 15 mm / 0.55 in 3
113
(10) mm¤ 1 AWG 20 - 8
0.5
6 kV/3
(10)2mm2​
800—
V/8
800
V/8
IN 10 A kV/3
IN 10 A​
!1
AWG 20 — 8​
600 V, 15 A U
600 V, 15 A 2
1
Terminal block width 10.4 mm / 0.409 in
Terminal block width 10.4 mm
/ 0.409 in​
L 13 - 15 mm / 0.55 in 3
59 mm/2.32 in
L 13 — 15 mm / 0.55 in​
59 mm/2.32 in
L 13 — 15 mm / 0.55 in​
1 Conductor sizes: 0.5 mm¤ o 10 mm¤ is + f-stw;
Push-in conductor sizes: 1 mm¤ o 10 mm¤ isw
and 1.5 mm¤ o 6 mm¤
iinsulated ferrule, 12 mmw
2 800 V = rated voltage
8 kV = rated surge voltage
3 = pollution degree
(see Section 14)
3 Strip length, see packaging or instructions.
96,3 mm/3.79 in
Pack.
Unit
Item No.
gray
2006-1631/099-000
25
Pack.
Unit
Item No.
Fuse disconnect terminal block with pivoting fuse
holder and end plate, gray,
with blown fuse indication by LED
Nominal voltage and current are given by the LED or fuse.
Leakage current in case of blown fuse: LED 2 mA,
for miniature metric fuses 1/4" x 11/4"
Fuse disconnect terminal block with pivoting fuse
holder and end plate,
without blown fuse indication
Nominal voltage and current are given by the fuse.
for miniature metric fuses 1/4" x 11/4"
Ǔ
4 See application notes for:
Star point jumper, page 140
96,3 mm/3.79 in
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
12 - 30 V
30 - 65 V
120 V
230 V
380 - 500 V
2006-1631/1099-541
2006-1631/1099-542
2006-1631/1099-867
2006-1631/1099-836
2006-1631/1099-859
25
25
25
25
25
2006
Series Accessories
Accessories
Appropriate marking systems: WMB/Marking strips
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
(see Section 13)
End plate for fuse terminal blocks,
2 mm thick
2006-992
orange
gray
2006-991
Push-in type jumper bar, insulated,
IN 25 A,
light gray
from 1 to 3
2002-433
from 1 to 5
2002-435
from 1 to 7
2002-437
from 1 to 9
2002-439
100 (4x25)
100 (4x25)
200
100
100
100
(8x25)
(4x25)
(4x25)
(4x25)
Star point jumper, insulated,
4
IN = IN terminal block, light gray
1-3-5
2002-405/011-000
100 (4x25)
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2006-115 100 (4x25)
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
5
Test plug,
with 500 mm cable,
2 mm 
red
210-136
50
For list of approvals and user guide, see pages 634 to 637.
Screwless end stop,
for DIN 35 rail,
6 mm wide
gray
249-116
Screwless end stop,
for DIN 35 rail,
10 mm wide
gray
249-117
Pivoting fuse holder with spare fuse holders
Protective warning markers must be applied individually.
Due to the 10.4 mm/0.409 in width of the fuse terminal
blocks with pivoting fuse holder, 2002 Series jumpers
must be used.
Miniature metric fuses
100 (4x25)
Series
Item No.
Overload and
short circuit protection
Individual
argmt.
50 (2x25)
2006-1611 7.5
2006-1621 7.5
2006-1631 7.5
2006-1631
/099-... 10.4
2006-1631
/1099-... 10.4
Group
argmt.
Short circuit
protection only
Individual
argmt.
Group
argmt.
Fused disconnect terminal blocks
1.6 W
1.6 W
2.5 W
2.5 W
1.6 W
1.6 W
2.5 W
2.5 W
1.6 W
1.6 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
When selecting miniature metric fuses, the maximum
power loss listed below should not be exceeded. The
power loss is determined according to IEC or EN 609477-3/VDE 0611-6 at 23¡C. The temperature rise of the terminal blocks must be checked according to their application and mounting. Higher ambient temperatures represent
an additional impact on miniature metric fuses. Therefore,
in such applications the rated current must be reduced if
necessary. More details are available from the fuse manufacturer.
63
?
TOPJOB¥@
TOPJOB¥@
Carrier
Blocks
1 Fuse
1Terminal
FusePlugs
Plugs and
on Carrier
Terminal
FuseBlocks
Plugs
6on(10)
Carrier
mm¤Terminal Blocks 6 (10) mm¤
2006
Series
2006
Series
2006
Series
116
116
Fuse plug with pull-tab
Fuse plug with pull-tab
Fuse plug with pull-tab
Fuse plug with pull-
800 V / IN 10 A
Plug width 7.4 mm / 0.291 in
800 V / IN 10 A
Plug width 7.4 mm / 0.291 in
800 V / IN 10 A
Plug width 10.4
7.4 mm
mm/ /0.291
0.409inin
800 V / IN 10 A
Plug width 10.4 mm
Circuit I
Circuit I
Circuit I
Circuit I
011\051\00115171_0.eps
011\051\00115211_0.eps
011\051\00115171_0.eps
011\051\00115201_0.eps
011\051\00115211_0.eps
011\051\00115201_0.eps
Item No.
Pack.
Unit
Item No.
gray
2006-911
Pack.
Unit
Ǔ
25
Ǔ
Ǔ
Ǔ
12
gray- 30 V
30 - 65 V
120 V
230 V
2006-911/1000-541
2006-911
25
2006-911/1000-542
2006-911/1000-867
2006-911/1000-836
25
25
25
25
Ǔ
for miniature metric fuses 5 x 30 mm
gray
2006-921
Ǔ
25
Ǔ
Ǔ
Ǔ
Ǔ
for miniature metric fuses 1/4" x 11/4"
gray
2006-931
25
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Item-Specific Accessories
End and intermediate plate, 1 mm thick
orange
2006-1692
gray
2006-1691
Accessories fuse plugs
Accessories
Item No.
for miniature metric fuses 5 x 30 mm
12
gray- 30 V
2006-921/1000-541
2006-921
25
30 - 65 V
2006-921/1000-542
120 V
2006-921/1000-867
230 V
2006-921/1000-836
380 - 500 V
2006-921/1000-859
25
25
25
25
25
pull-tab, gray,
Fuse plug with pull-tab
with indicator
lamp
Nominal
voltage
and current are given by the fuse.
Nominal
voltage
and
current
given by the LED or fuse.
for
miniature
metric
fuses
1/4"are
x 11/4"
Leakage current in case of blown fuse: LED 2 mA,
for miniature metric fuses 5 x 20 mm
Ǔ
Ǔ
Ǔ
Ǔ
gray
12 - 30 V
30 - 65 V
120 V
230 V
2006-931/099-000
2006-911/1000-541 2525
2006-911/1000-542
25
2006-911/1000-867
25
2006-911/1000-836
25
Fuse plug with pull-ta
Nominal voltage and cu
for miniature metric fuse
Ǔ
gray
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
for miniature metric fuses 5 x 30 mm
12 - 30 V
2006-921/1000-541
30 - 65 V
2006-921/1000-542
120 V
2006-921/1000-867
230 V
2006-921/1000-836
380 - 500 V
2006-921/1000-859
25
25
25
25
25
for miniature metric fuses 1/4" x 11/4"
12 - 30 V
2006-931/1000-541
30 - 65 V
2006-931/1000-542
120 V
2006-931/1000-867
230 V
2006-931/1000-836
380 - 500 V
2006-931/1000-859
25
25
25
25
25
for miniature metric fuses 1/4" x 11/4"
12
gray- 30 V
2006-931/1000-541
2006-931
25
30 - 65 V
2006-931/1000-542
120 V
2006-931/1000-867
230 V
2006-931/1000-836
380 - 500 V
2006-931/1000-859
25
25
25
25
25
Item-Specific Accessories
100 (4x25)
100 (4x25)
Pack.
Pack.
Unit
Unit
Ǔ
Fuse plug with pull-tab
pull-tab, gray,
with
indicator
lamp
Nominal
voltage
and current are given by the fuse.
Nominal
voltage
and
current
aremm
given by the LED or fuse.
for miniature
metric
fuses
5 x 20
Leakage current in case of blown fuse: LED 2 mA,
for miniature metric fuses 5 x 20 mm
Fuse plug with pull-tab
Nominal voltage and current are given by the fuse.
for miniature metric fuses 5 x 20 mm
Ǔ
Pack.
Unit
End and intermediate plate, 1 mm thick
orange
2006-1692
gray
2006-1691
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Item-Specific Accessories
100 (4x25)
100 (4x25)
Intermediate
End and intermediate
plate, 2.9plate,
mm thick
1 mm thick
orange
2006-1696
2006-1692
gray
2006-1695
2006-1691
Item-Specific Acc
100 (4x25)
100 (4x25)
Intermediate plate, 2.
orange
gray
Accessories fuse plugs
Appropriate
marking
systems:
WMB/Marking
strips
Appropriate
systems:
strips
Appropriate
marking
systems:
WMB/Marking
Stripsmarking
(see pages
96WMB/Marking
-101)
(see Section 13)
(see Section 13)
Screwless
end5stop,
Screwless end stop,
End plate for fuse terminal blocks,
Shorting
End platelink,
for fuse
5 x 20
terminal
mm, blocks,
Shorting link,
x 20 mm,
for
DIN
rail,is used as disconnect plug
for DIN
2 mm thick
if2 the
mmfuse
thickplug is used as disconnect plug
if the
fuse35plug
Iorange
IN mm
6.3 wide
A
6
6 mm w
orange
2006-992 100 (4x25)
281-503
2006-992 250
100(10x25)
(4x25)
281-503 250
100(10x25)
(4x25)
249-116
N 6.3 A
10
mm wide
gray
2006-991 100 (4x25)
gray
2006-991 100 (4x25)
gray
249-116
100 (4x25)
gray
249-117
2-conductor carrier terminal block,
2-conductor
carrier terminal
system, block,
Screwless
WMB Multiend
marking
stop, system,
Screwless end stop,
WMB
MultiPlug
marking
Disconnect
0.5 - 6 (10) mm¤ / AWG 20 - 8
10
0.5
strips
- 6 (10)
withmm¤
102006-401
markers
/ AWG per
20 100
-card,
8 (4x25)
for
10 DIN
strips35
with
rail,
10 markers per card,
for DIN
orange
Terminal block width 7.5 mm / 0.295 in
stretchable
Terminal block
5 - 5.2
width
mm7.5 mm / 0.295 in
10
stretchable
mm wide5 - 5.2 mm
10 mm
gray
2006-1661
25
plain
gray
793-5501
2006-1661
25
5
gray
plain
249-117
793-5501
50 (2x25)
5
gray
For list of approvals and user guide, see pages 634 to 637. For list of approvals and user guide, see pages 634 to 637.
64
116
!1
Fuse
Plugs and Carrier Terminal
Blocks, 2006 SeriesFuse plug with pull-tab
Fuse plug with pull-tab
Fuse plug with pull-tab
800 V / IN 10 A
Fuse
plug with
pull-tab
Plug width
7.4 mm
/ 0.291 in
800 V / IN 10 A
800 V / IN 10 A
The following features of the fuse plug ensure quick and
Using pluggable fuse holders with rail-mounted terminal
Plug
7.4 circuit
mm /protection
0.291 inis highly advantageous Plug
width 10.4 mm / 0.409 in
safe use:
blockswidth
for control
117
r Optional LED indicates blown fuse
r Markable fuse plug for clear coordination to the correct
carrier terminal block
r Two touch-proof test slots
r High density with only 7.5 mm/0.295 in width of
terminal block and fuse plug width 7.4 (10.4) mm
r Instead of a fuse, a shorting link may be used as a
disconnect plug
for the user, as the function and the wiring are accomplished by two separate parts:
r No additional cost for assembly and wiring
r No risk of accidental contact with live parts during
disconnection of fuse plug
r If exchanging a defective fuse, the fuse plug is
completely separated from the carrier terminal block.
This provides changeout away from current carrying
parts.
r The fuse plug can be removed by service personnel,
avoiding unintentional reclosing of the circuit by another
person
r Quick replacement a fuse by using a prepared istandby plug.w
800 V / IN 10 A
Plug width 10.4 mm / 0.409 in
Circuit I
Circuit I
011\051\00115211_0.eps
011\051\00115201_0.eps
Circuit I
1
Circuit I
011\051\00115171_0.eps
011\052\00115241_0.eps
Miniature metric fuse
Series
Item No.
Item No.
Ǔ
Pack.
Unit
Item No.
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
12 - 30 V
2006-931/1099-541
30 - 65 V
2006-931/1099-542
for miniature metric fuses 5 x 30 mm
120 V
2006-931/1099-867
gray
2006-921
25
230 V
2006-931/1099-836
380 - 500 V
2006-931/1099-859
25
25
25
25
25
Pack.
Unit
Fuse plug dimensions
12 - 30 V
2006-911/1000-541
30 - 65 V
2006-911/1000-542
120 V
2006-911/1000-867
230 V
2006-911/1000-836
25
25
25
25
for miniature metric fuses 5 x 30 mm
12 - 30 V
2006-921/1000-541
30 - 65 V
2006-921/1000-542
120 V
2006-921/1000-867
230 V
2006-921/1000-836
0,1
7,5
380 - 500 V
2006-921/1000-859
25
25
25
25
25
for miniature metric fuses 1/4" x 11/4"
12 - 30 V
2006-931/1000-541
30 - 65 V
2006-931/1000-542
120 V
2006-931/1000-867
230 V
2006-931/1000-836
380 - 500 V
2006-931/1000-859
25
25
25
25
25
Overload and
short circuit protection
Individual
argmt.
Fuse plug with pull-tab, gray,
with indicator lamp
Nominal voltage and current are given by the LED or fuse.
Leakage current in case of blown fuse: LED 2 mA,
for miniature metric fuses
5 xmm/3.79
20 mm in
93,3
Fuse plug with pull-tab
Nominal voltage and current are given by the fuse. Pack.
No.
for miniature metric fusesItem
5 x 20
mm
Unit
Fuse plug with pull-tab, gray,
with indicator lamp
Nominal voltage and current are given by the LED or fuse.
gray
2006-911
25
Leakage current in case of blown fuse: LED 2 mA,
for miniature metric fuses 1/4" x 11/4"
72 mm/2.83 in
1
TOPJOB¥@
Fuse Plugs on Carrier Terminal Blocks 6 (10) mm¤
?
2006 Series
Group
argmt.
Short circuit
protection only
Individual
argmt.
Group
argmt.
Pack.
FusedNo.
disconnect terminal blocks
Item
2006-911 7.5
1.6 W
1.6 W
2.5 W Unit
2.5 W
2006-921
7.5pull-tab
1.6 W
1.6 W
2.5 W
2.5 W
Fuse
plug with
2006-931 7.5
1.6 W
1.6 W
2.5 W
2.5 W
Nominal voltage and current are given by the fuse.
for 2006-931
miniature metric fuses 1/4" x 11/4"
/099-... 10.4
2006-931
/1099-... 10.4
Ǔ
gray
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2.5 W
2006-931/099-000
25
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
for miniature metric fuses 1/4" x 11/4"
gray
2006-931
25
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Item-Specific Accessories
End and intermediate plate, 1 mm thick
orange
2006-1692
gray
2006-1691
Item-Specific
Accessories
100 (4x25)
100 (4x25)
Intermediate plate, 2.9 mm thick
Accessoriesorange
fuse plugs2006-1696
gray
2006-1695
Item-Specific Accessories
Item-Specific Accessories
End and intermediate
plate,
N L1
N 1
L2 mm
N thick
L3
orange
2006-1692 100 (4x25)
gray
2006-1691 100 (4x25)
Open side of terminal block left
Intermediate plate, 2.9 mm thick
orange
2006-1696
gray
2006-1695
100 (4x25) When using the 10.4 mm/0.409 in wide plug,
Appropriate
marking systems: WMB/Marking strips
please note:
100 (4x25)
The extra width of the plug (10.4 mm/0.409 in compared
(see Section 13)
to 7.5 mm/0.295 in for carrier terminal blocks) must be
compensated
plates (2.9 mm) when
Screwless end stop,
End plate for fuse terminal blocks,
Shorting
link,for
5 xby20intermediate
mm,
building an assembly
carrier
terminal
equipped
for DIN 35 rail,
2 mm thick
if the of
fuse
plug is
used asblocks
disconnect
plug
with fuse plugs.
IN 6.3 A
6 mm wide
orange
2006-992 100 (4x25)
281-503 250 (10x25)
gray
2006-991 100 (4x25)
gray
249-116
2-conductor carrier terminal block,
WMB Multi marking system,
Screwless end stop,
10 strips with 10 markers per card,
for DIN 35 rail,
0.5 - 6 (10) mm¤ / AWG 20 - 8
stretchable 5 - 5.2 mm
10 mm wide
Terminal block width 7.5 mm / 0.295 in
gray
2006-1661
25
plain
793-5501
5
gray
249-117
100 (4x25)
100 (4x25)
100 (4x25)
50 (2x25)
For list of approvals and user guide, see pages 634 to 637.
65
Component Plugs, Diode and LED Modules
Carrier Version
Jumper Version
53,3 mm/2.1 in
Component plugs are available for carrier
terminal blocks and for insertion into adjacent
jumper slots. Empty component plugs can be
custom configured with component or small
PCB. In addition, pre-configured diode or LED
modules are available. Custom configurations
are available on request.
1 2 3
AC/DC
Marking with WMB markers or with
continuous marking strip
66
Testing can be peformed with 2-pole
test plugs
?
Plug-In Component Module for Carrier Terminal Block, 2002 Series
Diode Module; Diode 1N 4007
UN 250 V; URM 1000 V; 1 A max.
LED IF 25 mA
LED Module:
IN ≤ 5,6 mA; IF ≤ 25 mA
Width 5.2 mm / 0.205 in
Width 5.2 mm / 0.205 in
Item No.
Pack Unit​
Item No.​
Pack Unit​
Empty Module, 5.2 mm wide,
2002-800100
LED Module, 5.2 mm wide, with red LED
AC/DC 12 - 30 V
2002-800/1000-541 100
Diode Module, 5.2 mm wide,
Diode 1N 4007
2002-800/1000-411100
LED Module, 5.2 mm wide, with red LED
AC/DC 30 - 65 V
2002-800/1000-542 100
LED Module, 5.2 mm wide, with red LED
AC/DC 110 - 250 V
2002-800/1000-836 100
Accessories
2-Conductor Terminal Block, ➊
0.25 – 2.5 (4) mm2/AWG 22 –12
width 522 mm /0.205 in
gray
2002-166150
End and Intermediate Plate, 1 mm thick
orange​ 2002-1692100 (4 x 25)
gray
2002-1691100 (4 x 25)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Push-In Type Jumper, light gray, insulated, IN 25 A
2-Conductor Carrier Terminal Block, ➊
0.25 – 2.5 (4) mm2/AWG 22 –12
width 5.2 mm /0.205 in
gray
2002-166150
End and Intermediate Plate, 1 mm thick
orange​ 2002-1692100 (4 x 25)
gray
2002-1691100 (4 x 25)
2-way
2002-402 200 (8 x 25)
3-way
2002-403 200 (8 x 25)
4-way
2002-404 200 (8 x 25)
5-way
2002-405 100 (4 x 25)
6-way
2002-406 100 (4 x 25)
7-way
2002-407 100 (4 x 25)
8-way
2002-408 100 (4 x 25) 4-Conductor Carrier Terminal Block, ➋
4-Conductor Carrier Terminal Block, ➋
2002-409 100 (4 x 25) 0.25 – 2.5 (4) mm2/AWG 22 –12
0.25 – 2.5 (4) mm2/AWG 22 –12 9-way
10-way
2002-410
100
(4
x
25)
width
5.2 mm /0.205 in
width 5.2 mm /0.205 in
gray
2002-186150
gray
2002-186150
Push-In Type Jumper, light gray, insulated, IN 25 A
End and Intermediate Plate, 1 mm thick
End and Intermediate Plate, 1 mm thick
orange 2002-1892100 (4 x 25)
orange 2002-1892100 (4 x 25)
1 - 3
2002-433 200 (8 x 25) gray
2002-1891100 (4 x 25)
gray
2002-1891100 (4 x 25) 1 - 4
2002-434 200 (8 x 25)
1 - 5
2002-435 100 (4 x 25) Insulation Stop, 5 pcs/strip 200 Strips
Insulation Stop, 5 pcs/strip 200 Strips
1 - 6
2002-436 100 (4 x 25) light gray2002-171 0.25-0.5 mm2
light gray2002-171 0.25-0.5 mm2 1 - 7
2002-437 100 (4 x 25) dark gray2002-172 0.75-1 mm2
dark gray2002-172 0.75-1 mm2 1 - 8
2002-438 100 (4 x 25) 1 - 9
2002-439 100 (4 x 25) Test Plug Adapter, for test plug 4 mm Ø,
Test Plug, for test plug 4 mm Ø,
1 - 10 2002-440 100 (4 x 25) 2009-174 100 (4 x 25)
2009-174 100 (4 x 25) Slim Style Jumpers, light gray, insulated, IN 25 A
Testing Tap, for max. 2.5 mm²
2002-472 100 (4 x 25)
2009-182 100 (4 x 25) 2-way
3-way
2002-473 100 (4 x 25)
4-way
2002-474 100 (4 x 25)
5-way
2002-475 50 (2 x 25)
Protective Warning Marker, high voltages symbol,
5-way
2002-476 50 (2 x 25)
for 5 terminal blocks
2002-477 50 (2 x 25)
yellow 2002-115 100 (4 x 25) 5-way
5-way
2002-478 50 (2 x 25)
5-way
2002-479 50 (2 x 25)
5-way
2002-480 50 (2 x 25)
➊ 66.5 mm / 2.62 in (2-Conductor)
5-way
2002-481 50 (2 x 25)
➋ 87.5 mm / 3.45 in (4-Conductor)
12-way
2002-482 50 (2 x 25)
Testing Tap, for max. 2.5 mm²
2009-182 100 (4 x 25)
Protective Warning Marker, high voltages symbol,
for 5 terminal blocks
yellow 2002-115 100 (4 x 25)
➊ 66.5 mm / 2.62 in (2-Conductor)
➋ 87.5 mm / 3.45 in (4-Conductor)
67
?
Plug-In Component Module for Terminal Jumper Location, 2002 Series
Diode Module; Diode 1 N 4007
UN 250 V; URM 1000 V; 1 A max.
LED-Module:
IN ≤ 5,6 mA; IF ≤ 25 mA
Width 10.4 mm / 0,409 in
Width 10.4 mm / 0.409 in
Item No.
Empty Module, 10.4 mm wide,
2002-880
Item No.
Pack Unit​
Pack Unit​
LED Module, 10.4 mm wide, with red LED
AC/DC 12 - 30 V
+
AC/DC
2002-880/1000-541 50
50
_
LED Module, 10.4 mm wide, with red LED
AC/DC 30 - 65 V
+
AC/DC
2002-880/1000-542 50
Diode Module, 10.4 mm wide,
Diode 1N 4007
2002-880/1000-411 50
_
LED Module, 10.4 mm wide, with red LED
AC/DC 110 - 250 V
+
AC/DC
2002-880/1000-836 50
_
Accessories
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
2-Conductor Terminal Block, ➊
0.25 – 2.5 (4) mm2/AWG 22 –12
width 5.2 mm /0.205 in
gray
2002-1201100
End and Intermediate Plate, 0.8 mm thick
orange​ 2002-1292100 (4 x 25)
gray​
2002-1291100 (4 x 25)
2-Conductor Terminal Block, ➊
0.08 – 2.5 (4) mm2/AWG 28 –12
width 5.2 mm /0.205 in
gray
2002-1201100
End and Intermediate Plate, 0.8 mm thick
orange 2002-1292100 (4 x 25)
gray
2002-1291100 (4 x 25)
3-Conductor Terminal Block, ➋
0.25 – 2,5 (4) mm2/AWG 22 –12
width 5.2 mm /0.205 in
gray
2002-1301100
End and Intermediate Plate, 0.8 mm thick
orange​ 2002-1392100 (4 x 25)
gray​
2002-1391100 (4 x 25)
3-Conductor Terminal Block, ➋
0.08 – 2.5 (4) mm2/AWG 28 –12
width 5.2 mm /0.205 in
gray
2002-1301100
End and Intermediate Plate, 0.8 mm thick
orange 2002-1392100 (4 x 25)
gray
2002-1391100 (4 x 25)
4-Conductor Terminal Block, ➌
0.25 – 2.5 (4) mm2/AWG 22 –12
width 5.2 mm /0.205 in
gray
2002-1401100
End and Intermediate, 0.8 mm thick
orange​ 2002-1492100 (4 x 25)
gray​
2002-1491100 (4 x 25)
4-Conductor Terminal Block, ➌
0.08 – 2.5 (4) mm2/AWG 28 –12
width 5.2 mm /0.205 in
gray
2002-1401100
End and Intermediate Plate, 0.8 mm thick
orange 2002-1492100 (4 x 25)
gray
2002-1491100 (4 x 25)
➊ 48.5 mm / 1.91 in (2-Conductor)
➋ 59.5 mm / 2.34 in (3-Conductor)
➌ 70.0 mm / 2.76 in (4-Conductor)
68
?
!
TOPJOB
@
Component
Plug Housings on Carrier Terminal Blocks 2.5 (4) mm2
1 Empty
Empty Component Plug Housings on Carrier Terminal Blocks 2.5 (4) mm¤
2002 Series
Series
132 2002
¥
Empty component plug housing
Empty component plug housing
Plug width 5.2 mm / 0.205 in
(1 Watt Max.)
Plug width 10.4 mm / 0.409 in
(2 Watt Max.)
1 Length of 2002-1661: 66.5 mm / 2.62 in
2-conductor carrier terminal block
2 Length of 2002-1861: 87.5 mm / 3.45 in
4-conductor carrier terminal block
3 Length of 2002-1961: 72.9 mm / 2.87 in
2-conductor carrier terminal block with additional jumper position
4 See application notes for:
Colored push-in type jumper bars, page 139
Staggered jumper, page 141
Push-in type wire jumper, page 140
Item No.
Ǔ
Pack.
Unit
Empty component plug housing type 1,
2-pole,
5.2 mm wide
gray
2002-800
100
Item No.
Ǔ
Pack.
Unit
Accessories
Empty component plug housing type 2,
2-pole,
10.4 mm wide
gray
2002-810
50
Ǔ
Empty component plug housing type 3,
4-pole,
10.4 mm wide
gray
2002-820
50
Carrier
Term. Blocks and Accessories
Accessories
Appropriate marking system:
Appropriate marking systems: WMB/Marking
Strips (see pages 96 -101)
WMB/Marking strips
Push-in type wire jumper,
2-conductor carrier terminal block,
1
4
insulated,
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
IN 16 A,
Terminal block width 5.2 mm / 0.205 in
wire size 1.5 mm¤
gray
2002-1661
50
End and intermediate plate, 1 mm thick
L = 60 mm
2009-412 100 (10x10)
orange
2002-1692 100 (4x25)
L = 110 mm 2009-414 100 (10x10)
L = 250 mm 2009-416 100 (10x10)
gray
2002-1691 100 (4x25)
4-conductor carrier terminal block,
Push-in type jumper bar, insulated,
2
4
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
IN 25 A,
light gray
Terminal block width 5.2 mm / 0.205 in
gray
2002-1861
50
2-way
2002-402
End and intermediate plate, 1 mm thick
3-way
2002-403
orange
2002-1892 100 (4x25)
4-way
2002-404
5-way
2002-405
gray
2002-1891 100 (4x25)
6-way
2002-406
7-way
2002-407
2-conductor carrier terminal block,
3
8-way
2002-408
0.25 - 2.5 (4) mm¤ / AWG 22 - 12
9-way
2002-409
Terminal block width 5.2 mm / 0.205 in
10-way
2002-410
gray
2002-1961
50
End and intermediate plate, 1 mm thick
Push-in type jumper bar, insulated,
orange
2002-1992 100 (4x25)
IN 25 A,
gray
2002-1991 100 (4x25)
light gray
from 1 to 3
2002-433
from 1 to 4
2002-434
Insulation stop,
from 1 to 5
2002-435
5 pcs/strip,
from 1 to 6
2002-436
0.25 - 0.5 mm¤
from 1 to 7
2002-437
light gray
2002-171 200 (8x25)
from 1 to 8
2002-438
Insulation stop,
from 1 to 9
2002-439
5 pcs/strip,
from 1 to 10 2002-440
0.75 - 1 mm¤
dark gray
2002-172 200 (8x25)
Protective warning marker,
Multi-purpose operating tool,
with high-voltage symbol, black,
for component plugs
for 5 terminal blocks
2002-116
yellow
2002-115 100 (4x25)
For list of approvals and user guide, see pages 634 to 637.
200
200
200
100
100
100
100
100
100
(8x25)
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
200
200
100
100
100
100
100
100
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
Slim
style jumper
Staggered
jumper,
4
insulated,
IN 25 A,
light gray
2-way
3-way
4-way
5-way
6-way
7-way
8-way
9-way
10-way
11-way
12-way
2002-472
2002-473
2002-474
2002-475
2002-476
2002-477
2002-478
2002-479
2002-480
2002-481
2002-482
100
100
100
50
50
50
50
50
50
50
50
(4x25)
(4x25)
(4x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
(2x25)
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
WMB Multi marking system, plain,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
yellow
793-5501/000-002
red
793-5501/000-005
blue
793-5501/000-006
gray
793-5501/000-007
orange
793-5501/000-012
light green
793-5501/000-017
green
793-5501/000-023
violet
793-5501/000-024
5
5
5
69
Technical Information
Technical Information
1
133
53,3 mm/2.1 in
1
1 2 3
<______________ 25,8‒27 ______________>
Ø max.*
*  max. 3.4 mm at 5.2 mm module width and
*  max. 5.4 mm at 10.4 mm/0.409 in module width
Notice: Reconnection only possible with similar or larger
wire diameter. Smaller wire diameters must be soldered.
Component plugs for building custom circuits.
Solder-free assembly of diodes, resistors, etc.
Picture shows 1N4007 diode.
1±0,075
<__ 5 __>
Plugging a diode module into a through terminal block.
Diode module inserted in a through terminal block.
<___ 6 ___>
<________________ 19 ±0,2 ________________>
<____
When closing the cover, please insert cover as shown in
the illustration.
<____ 6 ____>
<_________ 12 +0,2
–0,1 _________>
Dimensions of self-assembled PCBs
Module height 2 mm at 5.2 mm module width and
module height 3.3 mm at 10.4 mm module width
Cutting component to the proper length.
70
Pressing component into plug contact via operating tool.
Pushing PCB into plug contact via operating tool.
>
Opening the cover via multi-purpose operating tool for
component plugs.
> max. 15,5 <
Ø 0,5‒1,1
_> <______
Application example showing a pluggable diode module.
Diode terminal blocks
These double and triple deck diode terminal blocks have been
specially developed for custom diode circuits such as lamp test
and collective fault signal circuits.
Using LED terminal blocks, monitoring units can be designed
for control and operating circuits.
The terminal blocks provide high density wiring maintaining a
width of only 5.2 mm.
Using push-in type jumper bars opens up additional
possibilities when designing custom circuits.
Custom configurations with diodes, resistor or LEDs available
on request.
Polarized diode gate,
common cathode
Double deck diode terminal blocks
+
+
++
–
Lamp test circuit
Triple deck diode terminal blocks
Open diode gate, can be
connected individually.
Using push-in type jumper
bars, individual levels can
be turned into polarized
diode gates.
71
?
Diode Terminal Blocks 1.5 (2.5) mm2 / AWG 14 and
LED Terminal Blocks 1.5 (2.5) mm2 / AWG 14; 2001 Series
0.25 – 1.5 (2.5) mm2 AWG 22 – 14
UN 250 V; URM 1000 V 1 N 4007 - 0.5 A continuous current
0.25 – 1.5 (2.5) mm2 AWG 22 – 14
UN 250 V; URM 1000 V 1 N 4007 - 0.5 A continuous current
0.25 – 1.5 (2.5)
DC 24 V
IF0.025 A max.
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
Terminal block width 4.2 mm / 0.165 in
L 9 – 11 mm / 0.39 in
mm2 AWG 22 – 14
can be connected: 0.25 mm2 - 4 mm2 "s+f-st";
can be pushed in directly; 0.5 mm2 - 2.5 mm2 "s" and 0.75 mm2 - 1.5 mm2 "insulated ferrule, 12 mm/0.472 in"
72
ItemPack.-unit
No.pcs
ItemPack.-unit
No.pcs
2-cond. diode term. blocks with diode 1 N 4007
2001-1211/1000-410 100
Circuit I, gray Circuit II, gray 2001-1211/1000-411 100
ItemPack.-unit
No.pcs
3-cond. diode term. blocks with diode 1 N 4007
2001-1311/1000-410 100
Circuit I, gray Circuit II, gray 2001-1311/1000-411 100
3-cond. LED term. blocks with red LED, 24 V DC
2001-1321/1000-434 100
Circuit I, gray Circuit II, gray 2001-1321/1000-413 100
Through terminal block with the same shape
gray
2001-1201
End and intermediate plate, 0.8 mm/0.032 in thick
orange 2002-1292
100 (4x25)
gray 2002-1291
100 (4x25)
Through terminal block with the same shape
gray
2001-1301
End and intermediate plate, 0.8 mm/0.032 in thick
orange 2002-1392
100 (4x25)
gray 2002-1391
100 (4x25)
Through terminal block with the same shape
gray
2001-1301
End and intermediate plate, 0.8 mm/0.032 in thick
orange
2002-1392
100 (4x25)
gray 2002-1391
100 (4x25)
ItemPack.-unit
No.pcs
4-cond. diode term. blocks with diode 1 N 4007
2001-1411/1000-410 100
Circuit I, gray Circuit II, gray 2001-1411/1000-411 100
4-cond. LED term. blocks with red LED, 24 V DC
2001-1421/1000-434 100
Circuit I, gray Circuit II, gray 2001-1421/1000-413 100
Through terminal block with the same shape
gray
2001-1401
End and intermediate plate, 0.8 mm/0.032 in thick
orange 2002-1492
100 (4x25)
gray 2002-1491
100 (4x25)
Through terminal block with the same shape
gray
2001-1401
End and intermediate plate, 0.8 mm/0.032 in thick
orange
2002-1492
100 (4x25)
gray 2002-1491
100 (4x25)
ItemPack.-unit
No.pcs
?
Diode Terminal Blocks 2.5 mm2 (4) mm2 / AWG 12 and
LED Terminal Blocks 2.5 (4) mm2 / AWG 12; 2002 Series
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
0.25 –2.5 (4) mm2 DC 24 V
IF 0.025 A max.
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
AWG 22 – 12
can be connected: 0.25 mm2 - 4 mm2 "s+f-st";
can be pushed in directly; 0.75 mm2 - 4 mm2 "s" and 0.75 mm2 - 2.5 mm2 "insulated ferrule, 12 mm/0.472 in"
ItemPack.-unit
No.pcs
ItemPack.-unit
No.pcs
2-cond. diode term. blocks with diode 1 N 4007
2002-1211/1000-410 100
Circuit I, gray Circuit II, gray 2002-1211/1000-411 100
ItemPack.-unit
No.pcs
3-cond. diode term. blocks with diode 1 N 4007
2002-1311/1000-410 100
Circuit I, gray Circuit II, gray 2002-1311/1000-411 100
3-cond. LED term. blocks with red LED, 24 V DC
2002-1321/1000-434 100
Circuit I, gray Circuit II, gray 2002-1321/1000-413 100
Through terminal block with the same shape
gray
2002-1201
End and intermediate plate, 0.8 mm/0.032 in thick
orange 2002-1292
100 (4x25)
gray 2002-1291
100 (4x25)
Through terminal block with the same shape
gray
2002-1301
End and intermediate plate, 0.8 mm/0.032 in thick
orange 2002-1392
100 (4x25)
gray 2002-1391
100 (4x25)
Through terminal block with the same shape
gray
2002-1301
End and intermediate plate, 0.8 mm/0.032 in thick
orange
2002-1392
100 (4x25)
gray 2002-1391
100 (4x25)
ItemPack.-unit
No.pcs
4-cond. diode term. blocks with diode 1 N 4007
2002-1411/1000-410 100
Circuit I, gray Circuit II, gray 2002-1411/1000-411 100
4-cond. LED term. blocks with red LED, 24 V DC
2002-1421/1000-434 100
Circuit I, gray Circuit II, gray 2002-1421/1000-413 100
Through terminal block with the same shape
gray
2002-1401
End and intermediate plate, 0.8 mm/0.032 in thick
orange 2002-1492
100 (4x25)
gray 2002-1491
100 (4x25)
Through terminal block with the same shape
gray
2002-1301
End and intermediate plate, 0.8 mm/0.032 in thick
orange
2002-1492
100 (4x25)
gray 2002-1491
100 (4x25)
ItemPack.-unit
No.pcs
73
?
Double Deck Diode Terminal Blocks / Double Deck LED Terminal Blocks
2.5 mm2/4 mm2 / AWG 12, 2002 Series
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
2
“s + f-st“;
c an be connected: 0.25 mm2 – 4 mm
can be pushed in directly: 0
and
.75 mm22 – 4 mm2 “s“
2
<_12 _>
<____ 70 mm /2.76 in
____>
Through terminal blocks with the same shape
see page 37
Description
Double deck diode terminal block
and
double deck LED terminal block, for DIN 35 rail
Accessories
End and
intermediate plate
Push-in type jumper bars, light
gray, insulated,
IN 25 A
Push-in type jumper bars, light
gray, insulated,
IN 25 A
Two-way marking adapter,
pivotable
< 52 mm /2.05
in >
< 52 mm /2.05
in >
0.75 mm – 2.5 mm “insulated ferrule, 12 mm“
I
<____ 70 mm /2.76 in
____>
II
I
Item
Pack. unit
No.pcs
Double deck diode terminal blocks
with diode 1 N 4007
Circuit ‑I, gray
2002-2211/1000-0410
50
Circuit II, gray
2002-2211/1000-0411
50
II
Item
Pack. unit
No.pcs
Double deck diode terminal blocks
with 2 diodes 1 N 4007
Circuit ‑I, gray
2002-2214/1000-0492
50
Circuit II, gray
2002-2214/1000-0491
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
0.8 mm /0.031 in thick
2002-2292
orange
gray
2002-2291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
2002-410
10-way
2002-433
1 - 3
2002-434
1 - 4
2002-435
1 - 5
:
:
2002-440
1 - 10
0.8 mm /0.031 in thick
2002-2292
orange
gray
2002-2291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
100 (4 x 25) 10-way
2002-410
200 (8 x 25) 1 - 3
2002-433
200 (8 x 25) 1 - 4
2002-434
100 (4 x 25) 1 - 5
2002-435
:
:
100 (4 x 25) 1 - 10
2002-440
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
2002-121
50 (2 x 25)
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25) 200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
2002-121
50 (2 x 25)
Examples of circuit configuration
+
– +
Used as recovery diodes
74
– +
–
+
+
Used in lamp test circuit
++
–
?
Double Deck Diode Terminal Blocks / Double Deck LED Terminal Blocks
2.5 mm2/4 mm2 / AWG 12, 2002 Series
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
0.25 –2.5 (4) mm2 DC 24 V
IF 25 mA max.
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<____ 70 mm /2.76 in
____>
I
<____ 70 mm /2.76 in
____>
II
I
<____ 70 mm /2.76 in
____>
I –
II
–
+
Item
Pack. unit
No.pcs
Double deck diode terminal blocks
with 2 diodes 1 N 4007
Circuit ‑I, gray
2002-2213/1000-0487
50
Circuit II, gray
2002-2213/1000-0488
50
Accessories
0.8 mm /0.031 in thick
2002-2292
orange
gray
2002-2291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
2002-410
10-way
AWG 22 – 12
< 52 mm /2.05
in >
< 52 mm /2.05
in >
< 52 mm /2.05
in >
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
Item
Pack. unit
No.pcs
Double deck diode terminal blocks
with 2 diodes 1 N 4007
Circuit ‑I, gray
2002-2214/1000-0489
50
Circuit II, gray
2002-2214/1000-0490
50
II +
+
+
–
–
Item
Pack. unit
No.pcs
Double deck LED terminal blocks
with red LED, DC 24 V
2002-2221/1000-0434 50
Circuit ‑I, gray
Circuit II, gray
2002-2221/1000-0413 50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
100 (4 x 25)
0.8 mm /0.031 in thick
2002-2292
orange
gray
2002-2291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
2002-410
10-way
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
0.8 mm /0.031 in thick
2002-2292
orange
gray
2002-2291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
100 (4 x 25) 10-way
2002-410
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
1 - 3
1 - 4
1 - 5
:
1 - 10
2002-433
2002-434
2002-435
:
2002-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
1 - 3
1 - 4
1 - 5
:
1 - 10
2002-433
2002-434
2002-435
:
2002-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
1 - 3
1 - 4
1 - 5
:
1 - 10
2002-433
2002-434
2002-435
:
2002-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
2002-121
50 (2 x 25)
2002-121
50 (2 x 25)
2002-121
50 (2 x 25)
+
+
+
Used in lamp test circuit
+
+
–
+
+
+
+
+
Used for collective fault indication
–
–
+ –
+ –
+
Used for voltage indication
75
?
Triple Deck Diode Terminal Blocks / Triple Deck LED Terminal Blocks
2.5 mm2/4 mm2 / AWG 12, 2002 Series
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
2
“s + f-st“;
c an be connected: 0.25 mm2 – 4 mm
can be pushed in directly: 0
.75 mm2 – 4 mm2 “s“ and 0.75 mm2 – 2.5 mm2 “insulated ferrule, 12 mm“
<___ 69,5 mm /2.74 in ___>
<___ 69,5 mm /2.74 in ___>
<________ 93,5 mm /3.68 in
________>
Through terminal blocks with the same shape
see page 40
Description
Triple deck diode terminal block
and
Triple deck LED terminal block, for DIN 35 rail
I
Accessories
End and
intermediate plate
Push-in type jumper bars, light
gray, insulated,
IN 25 A
Push-in type jumper bars, light
gray, insulated,
IN 25 A
Three-way marking adapter,
pivotable
76
<________ 93,5 mm /3.68 in
________>
II
I
Item
Pack. unit
No.pcs
Triple deck diode terminal blocks
with diode 1 N 4007
Circuit ‑I, gray
2002-3211/1000-0410
50
Circuit II, gray
2002-3211/1000-0411
50
<_12 _>
II
Item
Pack. unit
No.pcs
Triple deck diode terminal blocks
with diode 1 N 4007
Circuit ‑I, gray
2002-3211/1000-0675
50
Circuit II, gray
2002-3211/1000-0676
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
0.8 mm /0.031 in thick
2002-3292
orange
gray
2002-3291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
2002-410
10-way
2002-433
1 - 3
2002-434
1 - 4
2002-435
1 - 5
:
:
2002-440
1 - 10
2002-131
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
0.8 mm /0.031 in thick
2002-3292
orange
gray
2002-3291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
2002-410
10-way
2002-433
1 - 3
2002-434
1 - 4
2002-435
1 - 5
:
:
2002-440
1 - 10
50 (2 x 25)
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
2002-131
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
50 (2 x 25)
?
Triple Deck Diode Terminal Blocks / Triple Deck LED Terminal Blocks
2.5 mm2/4 mm2 / AWG 12, 2002 Series
0.25 –2.5 (4) mm2 AWG 22 – 12
UN 250 V; URM 1000 V
1 N 4007 – 0.5 A continuous current
0.25 –2.5 (4) mm2 DC 24 V
IF 25 mA max.
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
Terminal block width 5.2 mm / 0.205 in
L 10 – 12 mm / 0.43 in
<___ 69,5 mm /2.74 in ___>
<___ 69,5 mm /2.74 in ___>
AWG 22 – 12
<________ 93,5 mm /3.68 in
________>
I
<________ 93,5 mm /3.68 in
________>
II
I
Item
Pack. unit
No.pcs
Triple deck diode terminal blocks
with 3 diodes 1 N 4007
Circuit ‑I, gray
2002-3212/1000-0673
50
Circuit II, gray
2002-3212/1000-0674
50
Item
Pack. unit
No.pcs
Triple deck LED terminal blocks
with red LED, DC 24 V
2002-3221/1000-0434
50
Circuit ‑I, gray
Circuit II, gray
2002-3221/1000-0413
50
Accessories
0.8 mm /0.031 in thick
2002-3292
orange
gray
2002-3291
2002-402
2-way
2002-403
3-way
2002-404
4-way
2002-405
5-way
:
:
2002-410
10-way
1 - 3
1 - 4
1 - 5
:
1 - 10
II
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
0.8 mm /0.031 in thick
100 (4 x 25) orange
2002-3292
100 (4 x 25) gray
2002-3291
200 (8 x 25) 2-way
2002-402
200 (8 x 25) 3-way
2002-403
200 (8 x 25) 4-way
2002-404
100 (4 x 25) 5-way
2002-405
:
:
100 (4 x 25) 10-way
2002-410
100 (4 x 25)
100 (4 x 25)
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
2002-433
2002-434
2002-435
:
2002-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
1 - 3
1 - 4
1 - 5
:
1 - 10
2002-433
2002-434
2002-435
:
2002-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
2002-131
50 (2 x 25)
2002-131
50 (2 x 25)
77
TOPJOB®S is pluggable:
with X-COM® and X-COM®-MINI-Terminal Blocks
Slide the locking latch into the
desired position.
5.2 mm
3.5 mm
Plugs can be locked individually.
78
Coding pins can be used to protect
against mis-mating.
Series 2020
The female plugs have an integrated end
plate. As a result, an end plate must be
added to the last base terminal in that
section.
To code the female plug, first remove
the desired coding finger.
X-COM®S terminal blocks use the same jumper system as
the TOPJOB®S terminal blocks allowing them to be jumpered together (e.g. see terminal #16 X-COM®S and terminal
#17 TOPJOB®S).
TOPJOB®S test plug adapters can
also be used with series 2020
and 2022.
X-COM®S terminal blocks
can be snapped together
to form groups. Individual
terminal blocks can also
be removed via the actuation tool.
The notches shown above
allow the terminal blocks
to be easily separated.
Terminal blocks in both the series 2020
and 2022 can be jumpered together as
the jumper locations align.
Both base terminal blocks and
female plugs are touch safe.
Additional marking available with adapter.
79
X-COM®-SYSTEM MINI
1-Conductor/1-Pin Receptacle Terminal Blocks; 2-Conductor/2-Pin Receptacle
​​
Terminal Blocks​, 1.0 (1.5)mm2/AWG 16, 2020 Series
32,5 mm / __>
1.28 in
0.14 – 1 (1.5) mm2 AWG 24 – 16​
500 V/6 kV/3
300 V, 10 A U
IN 13.5 A*​​
300 V, 10 A 2
Terminal block width 3.5 mm / 0.137 in​​
L 9 – 11 mm / 0.39 in​​
<__
mm /
<__ 32,5
1.28 in __>
0.14 – 1 (1.5) mm2 AWG 24 – 16​
500 V/6 kV/3
300 V, 10 A U
IN 13.5 A*​​
300 V, 10 A 2
Terminal block width 3.5 mm / 0.137 in​​
L 9 – 11 mm / 0.39 in​​
(28,6mm/1.13in)
<__ 48,5 mm /1.91 in __>
<__ 46,9 mm/1.85 in __>
<____________ 85,2 mm /3.35 in ____________>
Description​​
1-conductor/1-pin receptacle terminal block,
suitable for DIN 35 rail acc. to EN 60715​​
1-conductor/1-pin receptacle terminal block
gray​​
2020-1201100
blue​​
2020-1204100
2-conductor/2-pin receptacle terminal block
gray​​
2020-1401100
blue​​
2020-1404100
1-conductor/1-pin ground receptacle terminal block
green-yellow​​
2020-1207100
2-conductor/2-pin ground receptacle terminal block
green-yellow​​
2020-1407100
2-conductor/2-pin receptacle terminal block,
suitable for DIN 35 rail acc. to EN 60715​
Accessories
End and
intermediate plate​​
Push-in type jumper bars,
light gray, insulated, IN 14 A​
Push-in type jumper bars,
light gray, insulated, IN 14 A ​
Carrier with 6 coding pins,
for coding of female plugs​​
Protective warning marker, with
high-voltage symbol,
for 5 terminal blocks​​
Test pin, Ø 1 mm/0.039 in​​
WMB Multi marking card,
Pin spacing: 3.5 mm/0.138 in,​
10 strips with 10 markers per card, white​
Marker strips,
on roll, 50 m,​
11 mm/0.039 in wide, white​
Item no.​​
Pack. unit
Item no.​​
Pack. unit
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
1 mm/0.039 in thick
gray​​
2020-1291
orange​​
2020-1292
2-way​​
2000-402
3-way​​
2000-403
4-way​​
2000-404
5-way​​
2000-405
​
:​​
10-way​​
2000-410
​
100 (4 x 25)
100 (4 x 25)​
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
from 1 to 3​​
from 1 to 4​​
from 1 to 5​​
:​​
from 1 to 10​​
2000-433
2000-434
2000-435
:​​
2000-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
orange​​
1 mm/0.039 in thick
gray​​
2020-1491
orange​​
2020-1492
2-way​​
2000-402
3-way​​
2000-403
4-way​​
2000-404
5-way​​
2000-405
​
:​​
10-way​​
2000-410
​
100 (4 x 25)
100 (4 x 25)​
200 (8 x 25)
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)
2000-433
2000-434
2000-435
:​​
2000-440
200 (8 x 25)
200 (8 x 25)
100 (4 x 25)
100 (4 x 25)​
from 1 to 3​​
from 1 to 4​​
from 1 to 5​​
:​​
from 1 to 10​​
2020-100
100 (4 x 25)​
orange​​
2020-100
100 (4 x 25)​
yellow​​
2000-115
100 (4 x 25)​
yellow​​
2000-115
100 (4 x 25)​
859-500
859-500
plain​
793-35015
plain​
793-35015
plain​
2009-1101
plain​
2009-1101
100 (4 x 25)​
*Current-carrying capacity curves on request​​
80
Volume
500 V/6 kV/3 2
IN 13.5 A 3
500 V/6 kV/3 2
IN 13.5 A 3
500 V/6 kV/3 2
IN 13.5 A 3
Terminal block width 3.5 mm / 0.138 in
X-COM @-SYSTEM-MINI Terminal block width 3.5 mm / 0.138 in
L 9 - 11 mm / 0.39 in 4
L 9 - 11 mm / 0.39 in 4
®
7 X-COM
1-Conductor/1-Pin
Carrier Terminal Blocks
MINI
-SYSTEMDouble-Deck
2020 Series
48 1-Conductor/1-Pin
Double-Deck Carrier Terminal Blocks​
1
20.14​​Series
30.14 - 1 (1.5) mm² 1 AWG 24 - 16
0.14 - 1 (1.5) mm² 2
- 1 (1.5) mm² 1 AWG 24 - 16
1 AWG 24 - 16
1.0
(1.5)mm /AWG 16, 2020
500 V/6 kV/3 2
500 V/6 kV/3 2
500 V/6 kV/3 2
2
1
2
mm2 AWG 24 – 16​
500
V/6
kV/3
300 V, 10 A U
Terminal block width 3.5 mm / 0.138 in
IN 13.5 A*​​
300 V, 10 A 2
L
9 - 11 mm
/ 0.39 in 4
Kein
Produktbild
!!
Terminal block width 3.5 mm / 0.137 in​​
L 9 – 11 mm / 0.39 in​​
3
3(1.5)
IN0.14
13.5–A 1
2
Pack.
Item No.
3
mm2 AWG 24 – 16​
500
V/6
kV/3
300 V, 10 A U
Terminal block width 3.5 mm / 0.138 in
IN 13.5 A*​​
300 V, 10 A 2
L
9 - 11 mm
/ 0.39 in 4
Kein
Produktbild
!!
Terminal block width 3.5 mm / 0.137 in​​
L 9 – 11 mm / 0.39 in​​
Pack.
Item No.
Unit !!
Kein Produktbild
1-conductor/1-pin double-deck carrier terminal
Unit !!
Kein Produktbild
1-conductor/1-pin double-deck carrier terminal
block, through/through terminal block,
with marker carrier,
housing color: gray
46,9 mm/1.8550
in
L/L
2020-2231
80,1 mm/3.15 in
N/L
50
2020-2232
L/N
50Pack.-unit
2020-2233
block, through/through terminal block,
with marker carrier,
housing color: blue
46,9 mm/1.8550
in
N
2020-2234
block, ground conductor/through terminal block,
with marker carrier,
housing color: gray
46,9 mm/1.8550
in
2020-2247
PE/N
80,1 mm/3.15 in
PE/L
50
2020-2257
46,9 mm/1.85 in
80,1 mm/3.15 in
Kein Produktbild !!
1
Kein Produktbild !!
2
80,1 mm/3.15 in
Kein Produktbild !!
2
without marker carrier, housing color gray
50
PE/N
1-conductor/1-pin
double-deck
carrier terminal
2020-2217
block,
ground conductor/through
50
PE/L
2020-2227terminal block,
without marker carrier,
housing color: gray
PE/N
50
2020-2217
PE/L
50
2020-2227
Kein Produktbild !!
3
46,9 mm/1.85 in
80,1 mm/3.15 in
Pack.Pack.-unit
Unit pcs
2-conductor/2-pin
double deck
carrier
terminal
2-conductor/2-pin
double-deck
carrier
terminal
block,
2-conductor/2-pin
through
terminal
block,
block,
2-conductor/2-pin
through
terminal
block,
marking
carrier,
internal
commoning,
withwith
marker
carrier,
internal
commoning,
conductor entry
connector
entry
colored violet, housing color blue
position
colored
in violet,
46,9 mm/1.85 in 50
N color: blue
2020-2239
housing
Item
Item
No.No.
Pack. Pack.-unit
pcs
51,3 mm/2.02 in
61,4 mm/2.41 in
without marker carrier, housing color blue
50
N
1-conductor/1-pin
double-deck
carrier terminal
2020-2204
block, through/through terminal block,
without marker carrier,
housing color: blue
N
50
2020-2204
46,9 mm/1.85 in
80,1 mm/3.15 in
Pack.-unit
Pack.
Unit pcs
2-conductor/2-pindouble-deck
double deckcarrier
carrier
terminal
2-conductor/2-pin
terminal
block,2-conductor/2-pin
2-conductor/2-pinthrough
throughterminal
terminal
block,
block,
block,
with marker
marking
carrier,
internal
commoning,
with
carrier,
internal
commoning,
conductor entry
connector
entry incolored
position
colored
violet, violet, housing color gray
46,9 mm/1.85 in50
L
housing
color: gray 2020-2238
ItemNo.
No.
Item
50
50
51,3 mm/2.02 in
61,4 mm/2.41 in
1
2020-2204
2020-2234
ItemItem
No. No.
1-conductor/1-pin double-deck carrierUnit
terminal
1-conductor/1-pin
double carrier
deck carrier
terminal
1-conductor/1-pin
double-deck
terminal
block,
ground conductor/through
terminal
block,
block,
ground
conductor/through
terminal
block,
block,
ground
conductor/through
terminal
block,
without marker carrier,
with marker
carrier, housing color gray
with
marker
carrier,
housing color: gray
50
PE/N
2020-2247
housing
color: gray 2020-2217
PE/N
50
2020-2257 50 50
2020-2247
PE/NPE/L
PE/L
50
2020-2227
PE/L
50
2020-2257
80,1 mm/3.15 in
51,3 mm/2.02 in
61,4 mm/2.41 in
Kein Produktbild !!
Pack.-unit
Pack.
Item No.
Item No.
pcs
1-conductor/1-pin double-deck carrierUnit
terminal
1-conductor/1-pin
double deck
carrier
terminal
1-conductor/1-pin
double-deck
carrier
terminal
block, through/through terminal block,
block,
through/through
terminal
block,
block,
through/through
terminal
block,
without
marker
carrier,
with
marker
carrier, housing color blue
with
marker
carrier,
housing color: blue
50
N color: blue
2020-2234
housing
51,3 mm/2.02 in
61,4 mm/2.41 in
51,3 mm/2.02 in
61,4 mm/2.41 in
L/N
50
2020-2203
L/N
50
2020-2233
without marker carrier, housing color gray
L/L
1-conductor/1-pin double-deck
terminal
2020-2201 carrier 50
block, through/through
terminal block,50
N/L
2020-2202
without marker carrier,
50
L/N
2020-2203
housing color: gray
2020-2201
L/L
50
N/L
50
2020-2202
L/N
50
2020-2203
80,1 mm/3.15 in
N
N
3
Pack.
Unit !!
Kein Produktbild
1-conductor/1-pin double-deck carrier terminal
Pack.
ItemNo.
No.
Item
pcs
1-conductor/1-pin double-deck carrierUnit
terminal
1-conductor/1-pin
double deckcarrier
carrier
terminal
1-conductor/1-pin
double-deck
terminal
block, through/through terminal block,
block,
through/throughterminal
terminalblock,
block,
block, marker
through/through
without
carrier,
with
marker carrier,
carrier, housing color gray
with
marker
housing color: gray
L/L
50
2020-2231
housing color: gray 2020-2201
L/L
50
N/L
2020-2232
L/L
2020-2231
5050
N/L
50
2020-2202
L/N
2020-2233
N/L
5050
2020-2232
3
46,9 mm/1.85 in
80,1 mm/3.15 in
51,3 mm/2.02 in
61,4 mm/2.41 in
46,9 mm/1.85 in
80,1 mm/3.15 in
51,3 mm/2.02 in
61,4 mm/2.41 in
Item No.
51,3 mm/2.02 in
61,4 mm/2.41 in
IN0.14
13.5–A 13(1.5)
46,9 mm/1.85 in
80,1 mm/3.15 in
51,3 mm/2.02 in
61,4 mm/2.41 in
1
mm2 AWG 24 – 16​
500
V/6
kV/3
300 V, 10 A U
Terminal block width 3.5 mm / 0.138 in
IN 13.5 A
300 V, 10 A 2
L
9 - 11 mm
/ 0.39 in 4
Kein
Produktbild
!!
Terminal block width 3.5 mm / 0.137 in​​
L 9 – 11 mm / 0.39 in​​
51,3 mm/2.02 in
61,4 mm/2.41 in
IN0.14
13.5–A 13(1.5)
2
51,3 mm/2.02 in
61,4 mm/2.41 in
1
Volume 1
1
51,3 mm/2.02 in
61,4 mm/2.41 in
Terminal block®width 3.5 mm / 0.138 in
L 9 - 11 mm / 0.39 in 4
Pack.-unit
Bestellnr. Pack.
Item No.
pcs
Unit
3
2-conductor/2-pin
doublecarrier
deck carrier
terminal
2-conductor/2-pin
double-deck
terminal
block,block, 2-conductor/2-pin ground conductor terminal
block, with marking
carrier,
internal
commoning,
2-conductor/2-pin
ground
conductor
terminal
block,
housingcarrier,
color internal
green-yellow
with marker
commoning,
46,9 mm/1.85 in
PE color: green-yellow2020-2237
50
housing
Kein Produktbild !!
80,1 mm/3.15 in
L
50
N
2020-2239
50
PE
2020-2237
50
2020-2238
without marking carrier, internal commoning,
without marking carrier, internal commoning,
without marking carrier, internal commoning,
Pack.
Pack.
Pack.
2-conductor/2-pin
double-deck
carrier
terminal
2-conductor/2-pin
double-deck
terminal
2-conductor/2-pin
double-deck
conductor entry colored
color
gray
conductor entry colored
violet, carrier
housing
color gray
housing color green-yellow
Itemviolet,
No. housing
Item No.
Item No. carrier terminal
Unit block,
Unit block,
Unit
block,
2-conductor/2-pin
through
terminal
block,
2-conductor/2-pin
through
terminal
block,
50
50
50
L
N
PE
2020-2208
2020-2209
2020-2207
2-conductor/2-pin
carrier terminal
2-conductor/2-pin
carrier terminal
2-conductor/2-pin ground
double-deck
carrier
terminal
without
marker carrier,double-deck
internal commoning,
conductor
without
marker carrier,double-deck
internal commoning,
conductor
2-conductor/2-pin
conductor
terminal
block,
block,
2-conductor/2-pin
through
terminal
block,
block,
2-conductor/2-pin
through
terminal
block,
block,
Appropriate
systems: WMB/Marking Strips
(see
pages
96internal
-101)commoning,
Accessories
entry
position colored in violet,
entry positionmarking
colored in violet,
without
marker
carrier,
with marker carrier,
commoning, conductor entry
with marker
commoning, conductor entry
2-conductor/2-pin
ground conductor terminal block,
housing
gray internal
housing
color:carrier,
blue internal
housing
color: green-yellow
End andcolor:
intermediate
plate, 1 mm thick
Marking
strip, white, plain
Double-deck
carrier,
position
coloredmarker
in violet,
with marker carrier, 2020-2207
internal commoning, 50
Lposition colored in violet,
50
N
2020-2209
50
PE
2020-2208
orange 2020-2292 100 (4 x 25)
11 mm wide
pivotable, gray
housing color: gray
housing
color: blue
housing color: green-yellow
gray 2020-2291 100 (4 x 25)
50 m roll 2009-110 1
2000-121
L
50
N
2020-2239
50 50 (4 x 25)
PE 2020-2237
50
2020-2238
Push-in
type jumper double-deck
bars, light gray,carrier
insulated,
IN 25 A
2-conductor/2-pin
terminal
2-way
2000-402
200 (8block,
x 25)
block, 2-conductor/2-pin through
terminal
2000-403
200
(8 x 25)
3-way
without marker carrier, internal
commoning,
conductor
2000-404 200 (8 x 25)
4-way
entry position colored in violet,
2000-405 100 (4 x 25)
5-way
housing color: gray
L
:
:
50
2020-2208
10-way 2000-410 100 (4 x 25)
Push-in type jumper
bars, light gray,
insulated,
IN 25 A
2-conductor/2-pin
double-deck
carrier
terminal
1 - 3
2000-433
200block,
(8 x 25)
block,
2-conductor/2-pin
through
terminal
2000-434 conductor
200 (8 x 25)
1 - 4commoning,
without
marker carrier, internal
position colored in 1
- 5 2000-435 100 (4 x 25)
entry
violet,
housing
color: blue
: :
N
2020-2209
50100 (4 x 25)
1 - 10 2000-440
WMB Multi marking
system, carrier terminal
2-conductor/2-pin
double-deck
10 strips with 10 markers per card,
block,
for conductor
3.5 mm terminal
block block,
width
2-conductor/2-pin ground
terminal
marker carrier, internal
plain commoning,
793-3501 5
without
housing color: green-yellow
PE
2020-2207
50
81
X-COM®-SYSTEM MINI
1-Conductor Female Plugs; 2-Conductor Female Plugs​
2020​​ Series
0.14 – 1 (1.5)
500 V/6 kV/3
IN 13.5 A*​​
mm2
AWG 24 – 16​​
300 V, 10 A U
300 V, 10 A 2
Module width 3.5 mm / 0.138 in​​
L 9 – 11 mm / 0.39 in​
​
0.14 – 1 (1.5)
500 V/6 kV/3
IN 13.5 A*​​
mm2
Module width
3.5 mm / 0.138 in​
AWG 24 – 16​​
300 V, 10 A U
300 V, 10 A 2
L 9 – 11 mm / 0.39 in​ ​
1 500 V​​ = rated voltage​
6 kV​​ = rated surge voltage​
3 = pollution degree​​
2The female plugs come equipped with
​ an end plate,
​ 0.7 mm/0.027 in thick.
​ The receptacle terminal blocks must also be
​ fitted with end plates.​
Description​​
No. of poles​​
1-conductor female plug with CAGE CLAMPS,
to be inserted into receptacle terminal blocks​
1-conductor female plug, with coding fingers, gray,
2 poles​​
2020-102100
3 poles​​
2020-103 50
:​​
:
14 poles​​2020-114
10
15 poles​​2020-115
10
2-conductor female plug with CAGE CLAMPS,
to be inserted into receptacle terminal blocks​
Item no.​​
Pack. unit
Additional poles and/or mixed (gray/blue/greenyellow) female plugs on request​​
Accessories
Locking levers
can be snapped on female plugs
Protective warning marker,
with high-voltage symbol,
for 5 terminal blocks​​
Strain relief plate, gray,
snap-on type,
for 1- and 2-conductor female plugs
Item no.​​
Pack. unit
2-conductor female plug, with coding fingers, gray,
2 poles​​
2020-202100
3 poles​​
2020-203 50
:​​
:
14 poles​​2020-214
10
15 poles​​2020-215
10
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Female plugs with 2 poles 3 poles and more
gray​
2022-141
2022-151 100 (4 x 25)
orange​
2022-142
2022-152 100 (4 x 25)
yellow​
2000-115100 (4 x 25)​
 2 to 3 poles​​
 4 to  6 poles​​
 7 to  9 poles​​
10 to 15 poles​​
WMB Multi marking card
Pin spacing: 3.5 mm/0.138 in,
plain​
10 strips with 10 markers per card, white​
Marker strips,
on roll, 50 m,
plain​
11 mm/0.039 in wide, white​
Test pin, Ø 1 mm/0.039 in​
82
No. of poles​​
734-327
734-328
734-329
734-326
Female plugs with 2 poles 3 poles and more
gray​
2022-141
2022-151
100 (4 x 25)
orange​
2022-142
2022-152
100 (4 x 25)
yellow​
2000-115100 (4 x 25)​
 2 to 3 poles​​
 4 to  6 poles​​
 7 to  9 poles​​
10 to 15 poles​​
734-327
734-328
734-329
734-326
793-35015
plain​
793-35015
2009-1101
plain​
2009-1101
859-500
859-500
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)​
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)​
X-COM®¥-SYSTEM-MINI
@SYSTEM
X-COM
MINI
Female
Plugs
for
Self-Assembly
Female Plugs for Self-Assembly
2020Series
Series
2020​​
7
386
12 AWG 24 - 16
1 (1.5)
mm¤
0.14
0.14- –
1 (1.5)
mm
AWG 24 – 16​​
500
500V/6
V/6kV/3
kV/32
300 V, 10 A U
13.5AA​​3
300 V, 10 A 2
ININ13.5
Module block
widthwidth
3.5 mm
0.138
in​​ in
Terminal
3.5/mm
/ 0.138
/ 0.39
in 4in​
L
L9 -911– mm
11 mm
/ 0.39
​
12 AWG 24 - 16
mm¤
0.14
0.14- 1
– (1.5)
1 (1.5)
mm
AWG 24 – 16​​
500
500V/6
V/6kV/3
kV/32
300 V, 10 A U
13.5AA​​3
300 V, 10 A 2
ININ13.5
Terminal block width 3.5 mm / 0.138 in
Module width 3.5 mm / 0.138 in​
L 9 - 11 mm / 0.39 in 4
L 9 – 11 mm / 0.39 in​ ​
Self-Assembly of Individual Female Plugs
Using modular of
female
plugs from
the X-COM
Individual
Female
Plugs S Self-Assembly
Intended
SYSTEM, female plugs can be customized for applica®
Using modular female plugs from the X-COM¥S-SYSTEM,
female
plugs can
be customized
tions requiring
varying
numbersfor
of applications
poles (e.g., requiring
when
varying
numbers
of poles (e.g., when designing prototydesigning
prototypes).
pes).
According
rupting cap
live or und
Assembly
The approp
that the ind
other witho
Modulesand
andPole
PoleNumbers
Numbers
Modules
A self-assembled
of:of:
self-assembledfemale
femaleplug
plugconsists
consists
Base
module
withwith
endend
plateplate
• base
module
and
max.
14
end
modules.
• and max. 14 end modules
!7
Intended Use
According to EN 61984, connectors without current
interrupting capacity shall not be mated and unmated
when live or under load.
Assembly
The appropriate mounting tool shall be used to
guarantee that the individual modules are properly
Self-Assembly of Individual Female Plugs¥
Intended Use
Using modular female plugs from the X-COM S-SYSTEM,
According to EN 61984, connectors without current interattached to each other without damaging the locking
female plugs can be customized for applications requiring rupting capacity shall not be mated and unmated when
latches.
varying numbers of poles (e.g., when designing prototylive or under load.
387
pes).
Ǔ
Ǔ
Ǔ
Modules and Pole Numbers
Pack.
A self-assembled female plug
consists of:
Item
Base module
withNo.
end plateUnit
and max. 14 end modules.
1-conductor end module,
with coding fingers
gray
2020-181
250
blue
2020-184
250
green-yellow
2020-187
250
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Ǔ
Assembly
The appropriate mounting tool shall be used to guarantee
Pack.
that the individual modules are
properly attached to each
No. the locking latches.
other withoutItem
damaging
Unit
2-conductor end module,
with coding fingers
gray
2020-281
blue
2020-284
green-yellow
2020-287
250
250
250
1 Conductor sizes: 0.14 mm¤ o 1.5 mm¤ is + f-stw;
Push-in conductor sizes: 0.5 mm¤ o 1.5 mm¤ isw
and 0.5 mm¤ o 0.75 mm¤
iinsulated ferrule, 10 mmw
1-conductor base module with end plate,
with coding fingers
gray
2020-161
250
blue
2020-164
250
green-yellow
2020-167
250
Ǔ
Ǔ
Ǔ
2-conductor base module with end plate,
with coding fingers
gray
2020-261
250
blue
2020-264
250
green-yellow
2020-267
250
2 500 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
Self-Assembly of Individual Female Plugs
Intended Use
Using modular female plugs from the X-COM S-SYSTEM,
According to EN 61984, connectors without current interSection
14)requiring rupting
female plugs can(see
be customized
for applications
capacity shall not be mated and unmated when
varying End
numbers Module
of poles (e.g., when designing prototylive or under load.
pes).
Assembly
curves upon request
3 Current-carrying capacity
¥
Modules and Pole Numbers
A self-assembled female plug consists of:
Base module with end plate
and max. 14 end modules.
!
The appropriate mounting tool shall be used to guarantee
that the individual modules are properly attached to each
other withoutor
damaging
the locking latches.
instructions.
4 Strip length, see packaging
1 Conductor sizes: 0.14 mm¤ o
Push-in conductor sizes: 0.5 m
and 0.5 mm¤ o 0.75 mm¤
iinsulated ferrule, 10 mmw
Accessories Female Plugs
Accessories
Appropriate marking systems: WMB/Marking strips
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
(see Section 13)
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2000-115 100 (4x25)
Locking lever,
9.6 mm wide
2022-152 100 (4x25)
Endorange
Module
gray
2022-151 100 (4x25)
Locking lever,
4.8 mm wide
2022-142 100 (4x25)
orange
gray
2022-141 100 (4x25)
Strain relief plate, gray
35 mm width 734-326
100 (4x25)
6 mm wide
734-327
100 (4x25)
12.5 mm width 734-328
100 (4x25)
25 mm wide
734-329 5-Pole,
100 (4x25)
Example:
1-Conductor
2 500 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(see Section 14)
3 Current-carrying capacity curv
4 Strip length, see packaging o
Example: 5-Pole, 1-Conductor Fe
End Module
Base Module
Base Module
Example: 5-Pole, 1-Conductor Female Plug
Female Plug
Base module with end plate
2020-167
WMB Multi marking system,
10 strips with 10 markers per card,
for 3.5 mm terminal block width
plain
793-3501
Marking strip, plain,
11 mm wide,
50 m roll
white
2009-110
End module
2020-184
5
1
End modules
2020-181
83
7
®
X-COM
-SYSTEM
¥
X-COM
@-SYSTEM-MINI
Pre-Assembled
Female
7 Pre-Assembled
FemalePlugs
Plugs
2020
Series
Series
388 2020
0.14 - 1
(1.5) mm¤ 1 AWG 24 - 16
2
0.14 – 1 (1.5) mm
500 kV/3
V/6 kV/3 2
500 V/6
IN A​​
13.5 A 3
IN 13.5
0.14 - 1
L 9 - 11 mm / 0.39 in 4
L 9 – 11 mm / 0.39 in​
L 9 - 11 mm / 0.39 in 4
​
Ǔ
Item No.
Pole
1
Pole
1
Pack.
Unit
Pole No.
2-conductor female plug with ground base module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers
3
2020-203/000-036
50
Ǔ
Ǔ
Item No.
2-conductor female plug with ground end module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers
3
2020-203/000-037
50
Ǔ
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2000-115 100
Locking lever,
9.6 mm wide
2022-152 100
orange
gray
2022-151 100
Locking lever,
4.8 mm wide
2022-142 100
orange
gray
2022-141 100
Strain relief plate, gray
35 mm width 734-326
100
6 mm wide
734-327
100
12.5 mm width 734-328
100
25 mm wide 734-329
100
L 9 – 11 mm / 0.39 in​ ​
Pole
1
Pack.
Unit
Pole No.
Ǔ
Item No.
Pole
1
Pack.
Unit
2-conductor female plug with ground base module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers
5
2020-205/000-036
50
2-conductor female plug with ground end module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers, green-yellow, blue, gray
3
2020-203/000-039
50
Ǔ
2-conductor female plug with ground end module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers
5
2020-205/000-037
50
For other lengths up to maximum 15 poles,
please contact factory.
Accessories Female Plugs
Accessories
N
Pole
1
2-conductor female plug with ground base module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers, gray, blue, green-yellow
3
2020-203/000-038
50
For other lengths up to maximum 15 poles,
please contact factory.
0.14 - 1 (1.5) mm¤ 1 AWG
- 16
0.14 – 1 (1.5)
mm2 24AWG
24 – 16​​
2
500500
V/6 V/6
kV/3kV/3
300 V, 10 A U
3
IN 13.5
A
I 13.5 A​​
module
widthwidth
3.5 mm 3.5
/ 0.138
mmin/ 0.138 in​
Module
L 9 - 11 mm / 0.39 in 4
​
For other lengths up to maximum 15 poles,
please contact factory.
Appropriate
marking
systems: WMB/Marking
Strips (see pages 96 -101)
Appropriate
marking systems:
WMB/Marking
strips
(see Section 13)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
WMB Multi marking system,
10 strips with 10 markers per card,
for 3.5 mm terminal block width
plain
793-3501
Marking strip, plain,
11 mm wide,
50 m roll
white
2009-110
5
1
For list of approvals and user guide, see pages 634 to 637.
84
module width
width 3.5
in in​​
Module
3.5mm
mm/ 0.138
/ 0.138
Pole
1
Pole No.
AWG 24 – 16​​
300 V, 10 A U
module
width
/ 0.138in​​
in
Module
width
3.5 3.5
mmmm
/ 0.138
L 9 – 11 mm / 0.39 in​
(1.5) mm¤ 1 AWG 24 - 16
0.14 – 1 (1.5)2mm2
500V/6
V/6 kV/3
kV/3
500
13.5A​​
A 3
ININ13.5
AWG 24 – 16​​
300 V, 10 A U
!7
X-COM®-SYSTEM
Pre-Assembled Female Plugs
2020 Series
mm¤mm
0.14
0.14- 1
– (1.5)
1 (1.5)
2
500
500V/6
V/6kV/3
kV/3
IINN13.5
13.5AA​​3
2
1 AWG
24 - 16
AWG 24 – 16​​
300 V, 10 A U
389
module
3.5 mm
0.138
in
3.5/mm
/ 0.138
in​
Modulewidth
width
L 9 - 11 mm / 0.39 in 4
L 9 – 11 mm / 0.39 in​ ​
Pole
1
Pole
1
1 Conductor sizes: 0.14 mm¤ o 1.5 mm¤ is + f-stw;
Push-in conductor sizes: 0.5 mm¤ o 1.5 mm¤ isw
and 0.5 mm¤ o 0.75 mm¤
iinsulated ferrule, 10 mmw
2 500 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(see Section 14)
3 Current-carrying capacity curves upon request
4 Strip length, see packaging or instructions.
Pole No.
Ǔ
Item No.
Pack.
Unit
2-conductor female plug with ground base module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers, gray, blue, green-yellow
5
2020-205/000-038
50
Ǔ
2-conductor female plug with ground end module
(green-yellow),
for insertion into carrier terminal blocks,
with coding fingers, green-yellow, blue, gray
5
2020-205/000-039
50
7
For other lengths up to maximum 15 poles,
please contact factory.
85
X-COM
-SYSTEM
-SYSTEM
X-COM¥@
Carrier
Terminal
Block
7 1-Conductor/1-Pin
1-Conductor/1-Pin Carrier
Terminal
Blocks
2
(4)mm
2022
Series/AWG 12, 2022 Series
394 2.5
®
12 AWG 22 - 12
mm¤
0.25 -–2.5
0.25
2.5(4)(4)
mm
AWG 22 – 12
690 V/6
V/6 kV/3
690
kV/32
600 V, 20 A U
24 A
IINN 24
A (32
(32A)
A)​​3
600 V, 20 A 2
1 2AWG
(4) (4)
mm¤mm
0.25
22 - 12
0.25- 2.5
– 2.5
AWG
22 – 12
Terminal block
5.2
mmmm
/ 0.205
in in​​
Terminal
blockwidth
width
5.2
/ 0.205
L 10 – 12 mm / 0.43 in​
¥
L 10 - 12 mm / 0.43 in 4
​
Terminalblock
block
width
/ 0.205
in​​
Terminal
width
5.25.2
mm mm
/ 0.205
in
4
10
12
mm
/
0.43
in
L
L 10 – 12 mm / 0.43 in​
​
X-COM @-SYSTEM
1-Conductor/1-Pin Carrier Terminal Blocks
2022 Series
394
32,5 mm/
1.28 in
0.25 - 2.5 (4) mm¤ 1 AWG 22 - 12
690 V/6 kV/3 2
IN 24 A (32 A) 3
0.25 - 2.5
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in 4
28,6 mm/1.13 in
48,5 mm/1.91 in
Item No.
(4) mm¤ 1 AWG 22 - 12
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in 4
28,6 mm/1.13 in
50,8 mm/2 in
Pack.
Unit
Item No.
!
1 Conductor sizes: 0.25 mm¤ o 4 mm¤ is + f-stw;
Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw
and 0.75 mm¤ o 2.5 mm¤
iinsulated ferrule, 12 mmw
32,5 mm/
1.28 in
7
!
Pack.
Unit
2 690 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
(also see Section 14)
3 See "Current-carrying capacity curves upon request"
see packaging or instructions.
4 Strip length,
Insert coding pin into the corresponding slot and twist it
off.
notes for:
5 See application
Colored push-in type jumper bars, page 139
Staggered jumper, page 141
Push-in typesizes:
wire 0.25
jumper,
page
mm¤
o 4140
mm¤ is + f-stw;
1 Conductor
Push-in conductor sizes: 0.75 mm¤ o 4 mm¤ isw
and 0.75 mm¤ o 2.5 mm¤
Accessories
iinsulated ferrule, 12 mmw
2 690 V = rated voltage
6 kV = rated surge voltage
3 = pollution degree
WMB
marking
(alsoMulti
see Section
14)system,
10 strips with 10 markers per card,
3 See "Current-carrying capacity curves upon request"
stretchable 5 - 5.2 mm
Item-Specific Accessories
4 Strip length, see packaging or instructions.
plain
793-5501
5
See Multi
application
notessystem,
for:
5
Protective warning marker,
WMB
marking
plain,
Colored push-in type jumper bars, page 139
with
symbol, black,
10 strips
with 10 markers per card,
28,6high-voltage
mm/1.13 in
28,6 mm/1.13 in
Staggered
page
Carrierjumper,
terminal blocks
and141
female plugs are protected
48,5 mm/1.91
50,8 mm/2 in
for 5 terminal
blocksin
stretchable
5 - 5.2140
mm
contact. page
Push-inagainst
type accidental
wire
jumper,
yellow
2002-115
100 (4x25)
yellow
793-5501/000-002
Pack.
Pack.
793-5501/000-005
Accessoriesred
2022 Series Accessories
Item No.
Item No.
Unit
Unit
blue
793-5501/000-006
WMB/WMB Inline/Marking
strips
Accessories
Appropriate
marking
systems:
WMB/Marking
Strips (seegray
pages 96 793-5501/000-007
-101)
1-conductor/1-pin
carrier terminal block,
1-conductor/1-pin
ground carrier
terminal
block,
(see
Section
13)
for DIN 35 rail, acc. to EN 60715
for DIN 35 rail, acc. to EN 60715
orange
793-5501/000-012
Slim
style jumper
WMB Multi marking
system, 793-5501/000-017
100
green-yellow
100
light green
Endgray
and intermediate2022-1201
plate, 1 mm thick
Staggered
jumper, 2022-1207
10
strips with 10793-5501/000-023
markers per card,
blue
100 100 (4x25) 5
green
orange2022-1204
2022-1292
insulated,
stretchable
5 - 5.2
mm
violet
793-5501/000-024
IN 25 A,
2022-1291 100 (4x25)
Item-Specificgray
Accessories
plain
793-5501
55
light gray
Protective
marker,
Insulation warning
stop,
WMB Multi
Inline,marking
plain, system, plain,
2-way
2002-472 100 (4x25) WMB
with
high-voltage symbol, black,
10
strips with
5 pcs/strip,
stretchable
5 10
- 5.2markers
mm, per card,
3-way
2002-473 100 (4x25)
for
5 terminal
blocks
stretchable
5 -markers,
5.2 mm 5 mm, on roll
4-way
2002-474 100 (4x25)
0.25
- 0.5 mm¤
1,500 WMB
yellow
2002-115
100 (8x25)
(4x25)
yellow
793-5501/000-002
5-way
2002-475
50 (2x25)
light gray
2002-171 200
white
2009-115
1
red
793-5501/000-005
6-way
2002-476
50 (2x25) Marking strip, plain,
Insulation
stop, Accessories
2022
Series
blue
7-way
2002-477
50 (2x25)
5 pcs/strip,
11 mm wide, 793-5501/000-006
WMB/WMB Inline/Marking strips
gray
793-5501/000-007
8-way
2002-478
50 (2x25)
0.75 - 1 mm¤
50 m roll
(see
Section 13)
orange
793-5501/000-012
9-way
2002-479
50 (2x25)
dark gray
2002-172 200
(8x25)
white
2009-110
1
793-5501/000-017
10-way
2002-480
50 (2x25) Screwless end light
End
andtype
intermediate
plate,
1 mm thick
Staggered jumper,
Push-in
jumper bar,
insulated,
stop,green
5
green
11-way
2002-481
50 (2x25)
orange
2022-1292 100 (4x25) 5
insulated,
IN 25 A,
for DIN 35 rail,793-5501/000-023
violet
793-5501/000-024
2002-482
50 (2x25)
I12-way
gray
2022-1291 100 (4x25)
light gray
6 mm wide
N 25 A,
5
light gray
2-way
2002-402 200 (8x25)
gray
249-116
100 (4x25)
Insulation stop, 3-way
2-way
2002-472 100 (4x25) WMB Inline, plain,
2002-403 200 (8x25) Push-in type wire
jumper,
54-way
pcs/strip,
stretchable 5 - 5.2 mm,
3-way
2002-473 100 (4x25)
2002-404 200 (8x25) 5
insulated,
4-way
2002-474 100 (4x25)
0.25
1,500 WMB markers, 5 mm, on roll
5-way- 0.5 mm¤ 2002-405 100 (4x25)
IN 16 A,
5-way
2002-475
50 (2x25)
light
gray
2002-171
white
2009-115
1
6-way
2002-406 200
100 (8x25)
(4x25)
wire size 1.5 mm¤
6-way
2002-476
50(10x10)
(2x25) Marking strip, plain,
Insulation stop, 7-way
2002-407 100 (4x25)
L = 60 mm
2009-412 100
7-way
50(10x10)
(2x25)
2002-408 100 (4x25)
58-way
pcs/strip,
11 mm wide,
L = 110 mm 2002-477
2009-414 100
8-way
50(10x10)
(2x25)
9-way- 1 mm¤ 2002-409 100 (4x25)
0.75
50 m roll
L = 250 mm 2002-478
2009-416 100
9-way
2002-479
50 (2x25)
10-way
2002-410 200
100 (8x25)
(4x25)
dark
gray
2002-172
white
2009-110
1
10-way pins, 2002-480
50 (2x25) Screwless end stop,
Push-in
Push-in type
type jumper
jumper bar,
bar, insulated,
insulated,
Carrier with 6 coding
5
11-way
2002-481
50 (2x25)
IINN 25
for DIN 35 rail,
25 A,
A,
for coding female
plugs
12-way
2002-482
50 (2x25)
light
6 mm wide
light gray
gray
orange
2022-100 100
(4x25)
2-way
2002-402
gray
249-116
100 (4x25)
from 1 to 3
2002-433 200
200 (8x25)
(8x25)
3-way
2002-403
from 1 to 4
2002-434 200
200 (8x25)
(8x25) Push-in
Test pin,type wire jumper,
4-way
2002-404
insulated,
from 1 to 5
2002-435 200
100 (8x25)
(4x25) 5
1 mm 
5-way
2002-405
IN 16 A,
from 1 to 6
2002-436 100
100 (4x25)
(4x25)
859-500
1
6-way
2002-406
wire size 1.5 mm¤
from 1 to 7
2002-437 100
100 (4x25)
(4x25)
7-way
2002-407
L = 60plug
mm
2009-412 100 (10x10)
from 1 to 8
2002-438 100
100 (4x25)
(4x25) 1-conductor female
8-way
2002-408
Lgray
= 110 mm 2009-414
from 1 to 9
2002-439 100
100 (4x25)
(4x25)
2022-101 100 (10x10)
200
9-way
L = 250 mm 2009-416 100 (10x10)
from 1 to 10 2002-409
2002-440 100
100 (4x25)
(4x25)
10-way
2002-410 100 (4x25)
Push-in
jumper
bar,
For
list oftype
approvals
and
userinsulated,
guide, see pages 634 to 637. Carrier with 6 coding pins,
IN 25 A,
for coding female plugs
86
light gray
orange
2022-100 100 (4x25)
from 1 to 3
2002-433 200 (8x25)
Ǔ
1-conductor/1-pin ground carrier terminal block,
for DIN 35 rail, acc. to EN 60715
green-yellow
2022-1207
100
32,5 mm/
1.28 in
Ǔ
32,5 mm/
1.28 in
Ǔ
1-conductor/1-pin carrier terminal block,
for DIN 35 rail, acc. to EN 60715
gray
2022-1201
100
blue
2022-1204
100
Ǔ
Ǔ
Ǔ
X-COM®-SYSTEM
2-Conductor/1-Pin-Receptacle and 2-Conductor/2-Pin-Receptacle Terminal Block
2.5 (4)mm2/AWG 12, 2022 Series
AWG 22 - 12
600 V, 20 A U
600 V, 20 A 2
AWG 22 - 12
600 V, 20 A U
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
32,5 mm/
1.28 in
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
0.25 - 2.5 (4) mm²
690 V/6 kV/3
IN 24 A (28 A)
39,2 mm/1.55 in
59,2 mm/2.33 in
Item No.
2-Conductor/1-Pin-Receptacle,
suitable for DIN 35 rail
gray
2022-1301
blue
2022-1304
32,5 mm/
1.28 in
0.25 - 2.5 (4) mm²
690 V/6 kV/3
IN 24 A (32 A)
46,6 mm/1.83 in
86,2 mm/3.39 in
Pack.-unit
pcs
100
100
2-Conductor/1-Pin-Ground-Receptacle,
suitable for DIN 35 rail
100
green-yellow
2022-1307
Item No.
2-Conductor/2-Pin-Receptacle,
suitable for DIN 35 rail
gray
2022-1401
blue
2022-1404
Pack.-unit
pcs
50
50
2-Conductor/2-Pin-Ground-Receptacle,
suitable for DIN 35 rail
50
green-yellow
2022-1407
Accessories - Item Specific
End and intermediate plate, 1 mm thick
orange
2022-1392
gray
2022-1391
Accessories
100 (4x25)
100 (4x25)
End and intermediate plate, 1 mm thick
orange
2022-1492
gray
2022-1491
100 (4x25)
100 (4x25)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Push-in type wire jumpers, isolated,
Continuous marking strip, blank
IN 16 A,
11 mm wide,
wire size 1.5 mm²
0.25 - 0.5 mm²
50 m roll
60 mm
2009-412 100 (10x10)
light gray
2002-171 200 (8x25)
white
2009-110
110 mm
2009-414 100 (10x10) WMB Inline, blank,
0.75 - 1 mm²
dark gray
2002-172 200 (8x25)
5 - 5.2 mm
250 mm
2009-416 100 (10x10)
1,500 WMB-markers on 5 mm roll
Carrier wiht 6 coding pins
Push-in type jumper bars, light gray, insulated
white
1
2009-115
for coding of female plugs
IN 25 A,
2-way
2002-402 200 (8x25)
orange
2022-100 100 (4x25)
3-way
2002-403 200 (8x25)
Slim Style Jumpers, light gray, insulated, IN 25 A
4-way
2002-404 200 (8x25) Test pin,
2-way
2002-472 100 (4 x 25)
:
1 mm Ø
3-way
2002-473 100 (4 x 25)
10-fach
2002-410 100 (4x25)
1 4-way
859-500
2002-474 100 (4 x 25)
Push-in type jumper bars, light gray, insulated
Protective warning marker, with high voltage symbol
5-way
2002-475 50 (2 x 25)
IN 25 A,
for 5 mm terminal blocks
5-way
2002-476 50 (2 x 25)
yellow
2002-115 100 (4x25) 5-way
2002-477 50 (2 x 25)
1-3
2002-433 200 (8x25)
5-way
2002-478 50 (2 x 25)
1-4
2002-434 200 (8x25) 1-conductor female plug
5-way
2002-479 50 (2 x 25)
1-5
2002-435 100 (4x25)
gray
200 5-way
2022-101
2002-480 50 (2 x 25)
:
5-way
2002-481 50 (2 x 25)
1 - 10
2002-440 100 (4x25)
12-way
2002-482 50 (2 x 25)
WMB multi marking card
10 strips with 10 markers each
5 - 5.2 mm
blank
5
793-5501
Insulation stop, 5 pcs / Strip,
87
X-COM®-SYSTEM
1-Conductor/1-Pin Double Deck Receptacle Terminal Blocks
2.5 (4)mm2/AWG 12, 2022 Series
AWG 22 - 12
600 V, 20 A U
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
51,3 mm/2.02 in
61,4 mm/2.41 in
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
0.25 - 2.5 (4) mm²
690 V/6 kV/3
IN 24 A (28 A)
46,9 mm/1.85 in
80,1 mm/3.15 in
Item No.
46,9 mm/1.85 in
80,1 mm/3.15 in
Pack.-unit
pcs
AWG 22 - 12
600 V, 20 A 2
Terminal block width 5.2 mm / 0.205 in
L 10 - 12 mm / 0.43 in
Item No.
46,9 mm/1.85 in
80,1 mm/3.15 in
Pack.-unit
pcs
Item No.
Pack.-unit
pcs
without marker carrier, housing color gray
50
L/L
2022-2201
50
N/L
2022-2202
50
L/N
2022-2203
without marker carrier, housing color blue
50
N/N
2022-2204
without marker carrier, housing color gray
50
PE/N
2022-2217
50
PE/L
2022-2227
Item No.
Pack.-unit
pcs
46,9 mm/1.85 in
80,1 mm/3.15 in
Item No.
Pack.-unit
pcs
51,3 mm/2.02 in
61,4 mm/2.41 in
1-conductor/1-pin double deck receptacle,
ground/through
with marker carrier, housing color gray
50
PE/N
2022-2247
50
PE/L
2022-2257
51,3 mm/2.02 in
61,4 mm/2.41 in
1-conductor/1-pin double deck receptacle,
through/through
with marker carrier, housing color blue
50
N/N
2022-2234
51,3 mm/2.02 in
61,4 mm/2.41 in
1-conductor/1-pin double deck receptacle,
through/through
with marker carrier, housing color gray
L/L
50
2022-2231
50
N/L
2022-2232
50
L/N
2022-2233
46,9 mm/1.85 in
80,1 mm/3.15 in
46,9 mm/1.85 in
80,1 mm/3.15 in
Bestellnr.
Pack.-unit
pcs
2-conductor/2-pin double deck receptacle
feed through
with marking carrier, internal common
connector entry colored violet, housing color gray
L
50
2022-2238
2-conductor/2-pin double deck receptacle
feed through
with marking carrier, internal common
connector entry colored violet, housing color blue
N
50
2022-2239
2-conductor/2-pin double deck receptacle
ground
with marking carrier, internal common
housing color green-yellow
PE
50
2022-2237
without marking carrier, housing color gray
50
L
2022-2208
without marking carrier, housing color blue
50
N
2022-2209
with marking carrier, housing color green-yellow
50
PE
2022-2207
Accessories
88
0.25 - 2.5 (4) mm²
690 V/6 kV/3
IN 24 A (28 A)
51,3 mm/2.02 in
61,4 mm/2.41 in
AWG 22 - 12
600 V, 20 A U
600 V, 20 A 2
51,3 mm/2.02 in
61,4 mm/2.41 in
0.25 - 2.5 (4) mm²
690 V/6 kV/3
IN 24 A (28 A)
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
End and intermediate plate, 1 mm thick
orange 2022-2292 100 (4 x 25)
gray 2022-2291 100 (4 x 25)
Double-deck marker carrier,
pivotable, gray
2002-121
Push-in type jumper bars, light gray, insulated, IN 25 A
2-way 2002-402 200 (8 x 25)
3-way 2002-403 200 (8 x 25)
4-way 2002-404 200 (8 x 25)
5-way 2002-405 100 (4 x 25)
:
:
10-way 2002-410 100 (4 x 25)
Push-in type jumper bars, light gray, insulated, IN 25 A
1 - 3 2002-433 200 (8 x 25)
1 - 4 2002-434 200 (8 x 25)
1 - 5 2002-435 100 (4 x 25)
: :
1 - 10 2002-440 100 (4 x 25)
50 (4 x 25)
Marking strip, white, plain
11 mm wide
50 m roll 2009-110 1
WMB Multi marking system,
10 strips with 10 markers per card,
for 3.5 mm terminal block width
plain
793-5501 5
X-COM®-SYSTEM
1-Conductor Female Plugs​
2022​ Series
0,25 — 2.5 (4)
690 V/6 kV/3 IN 24 (32) A*
mm2
AWG 22 — 12
600 V, 20 A U
600 V, 20 A 2
Module width 5.2 mm / 0.205 in
L 10 — 12 mm / 0.43 in
Description
No. of poles
1-conductor female plug with CAGE CLAMPS connection,
to be fixed on receptacle terminal blocks
or male connectors
1-conductor female plugs, with coding fingers, gray,
1 pole
2022-101 200
2 poles
2022-102 100
3 poles
2022-103
50
:​
:
14 poles2022-114
10
15 poles2022-115
10
Higher number of poles and/or mixed
(gray/blue/green-yellow) female plugs on request
Item no.
Pack. unit​
For other lengths, please contact factory
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Accessories
Insulation stop ➋,
5 pieces/strip
light gray
dark gray
Locking levers,
can be snapped on female plugs gray
orange
Protective warning marker, yellow
with high-voltage symbol,
for 5 terminal blocks
Strain relief plate,
gray
snap-on type,
for 1-conductor
female plugs
Test pin, 1 mm/0.039 in Ø
0.25 — 0.5 mm2
0.75 — 1 mm2
2002-171
2002-172
200 strips
200 strips
Female plugs with 1 pole 2 poles and more
2022-141 2022-151 100 (4 x 25)
2022-142 2022-152 100 (4 x 25)
2002-115
100 (4 x 25)
2-pole
3- to 4-pole
5- to 6-pole
7- to 10-pole
11- to 14-pole
15-pole
734-327
734-328
734-329
734-326
734-430
734-431
859-500
To code a female plug, remove the desired
coding finger using a suitable tool . . .
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
100 (4 x 25)
50 (2 x 25)
50 (2 x 25)
*Current-carrying capacity curves on request
. . . and insert a 2022-100 coding pin into
the corresponding location of the receptacle
terminal block.
89
X-COM¥@-SYSTEM
®
X-COM
SYSTEM
Female Plugs
for Self-Assembly
Female
Plugs
for Self-Assembly,
2022
Series
402
7
0.25 - 2.5 (4) mm¤2​​1 AWG 22 - 12
0.25
– 2.5 (4) mm AWG 22 – 12​​
690 V/6
690
V/6 kV/3
kV/32
600 V, 20 A u
(32A
A) 3
IINN 24 A(32)
600 V, 20 A 2
Terminal block
mm
/ 0.205
in in​​
Terminal
blockwidth
width5.2
5.2
mm
/ 0.205
L 10 – 12 mm / 0.43 in​​
L 10 - 12 mm / 0.43 in 4
Item No.
Ǔ
Ǔ
Ǔ
1-conductor end module,
with coding fingers
gray
2022-181
blue
2022-184
green-yellow
2022-187
2022 Series​​
Self-Assembly of Individual Female Plugs
Using modular female plugs from the X-COM®SSYSTEM, female plugs can be customized for applications requiring varying numbers of poles (e.g., when
designing prototypes).
Modules and Pole Numbers
A self-assembled female plug consists of:
• base module with end plate
• and max. 14 end modules
Pack.
Unit
Intended Use
According to EN 61984, connectors without current
interrupting capacity shall not be mated and unmated
when live or under load.
Assembly
The appropriate mounting tool shall be used to
guarantee that the individual modules are properly
attached to each other without damaging the locking
latches.
250
250
250
End Module
Ǔ
Ǔ
Ǔ
1-conductor center module,
with coding fingers
gray
2022-171
blue
2022-174
green-yellow
2022-177
250
250
250
Ǔ
Ǔ
Ǔ
1-conductor base module, with integrated end plate,
with coding fingers
gray
2022-161
250
blue
2022-164
250
green-yellow
2022-167
250
Center Module
Accessories Female Plugs
Accessories
Appropriate marking systems: WMB/Marking strips/WMB Inline
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
(see Section 13)
Insulation stop,
5 pcs/strip,
0.25 - 0.5 mm¤
light gray
2002-171 200
Insulation stop,
5 pcs/strip,
0.75 - 1 mm¤
dark gray
2002-172 200
Locking lever,
4.8 mm wide
orange
2022-142 100
gray
2022-141 100
Locking lever,
9.6 mm wide
orange
2022-152 100
gray
2022-151 100
Protective warning marker,
with high-voltage symbol, black,
for 5 terminal blocks
yellow
2002-115 100
Strain relief plate, gray
35 mm width 734-326
100
6 mm wide
734-327
100
12.5 mm width 734-328
100
25 mm wide 734-329
100
55 mm width 734-430
50
75 mm width 734-431
50
(8x25)
(8x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(4x25)
(2x25)
(2x25)
For list of approvals and user guide, see pages 634 to 637.
90
WMB Multi marking system,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
plain
793-5501
WMB Multi marking system, plain,
10 strips with 10 markers per card,
stretchable 5 - 5.2 mm
yellow
793-5501/000-002
red
793-5501/000-005
blue
793-5501/000-006
gray
793-5501/000-007
orange
793-5501/000-012
light green
793-5501/000-017
green
793-5501/000-023
violet
793-5501/000-024
5
Base Module
Example: 5-Pole, 1-Conductor Female Plug​​
5
WMB Inline, plain,
stretchable 5 - 5.2 mm,
1,500 WMB markers, 5 mm, on roll
white
2009-115
Marking strip, plain,
11 mm wide,
50 m roll
white
2009-110
1
Base module
with integrated end plate
2022-167​
1
Center module
2022-174​
Center modules
2022-171​
End module
2022-181​
X-COM®-SYSTEM
Pre-Assembled Female Plugs​, 2022 Series
0.25 – 2.5 (4) mm2
690 V/6 kV/3 ➊
IN 24 (32) A*​​
AWG 22 – 12​​
600 V, 20 A U
Module width 5.2 mm / 0.205 in​​
Item no.​​
AWG 22 – 12​​
600 V, 20 A U
Pack. unit​
No. of poles​​
Item no.​​
Pack. unit​
1-conductor female plug, with coding fingers,
gray, green-yellow ​
1-conductor female plug, with coding fingers,
gray, blue, green-yellow, ​
2022-103/000-037
50
Accessories
200 (8x25)
200 (8x25)
Locking lever,
4.8 mm wide
orange
2022-142 100 (4x25)
gray
2022-141 100 (4x25)
Locking lever,
9.6 mm wide
orange
2022-152 100 (4x25)
gray
2022-151 100 (4x25)
Protective warning marker, with high voltage symbol
for 5 mm terminal blocks
yellow
2002-115 100 (4x25)
Strain relief plate, gray
3.5 mm wide
6 mm wide
12.5 mm wide
25 mm wide
55 mm wide
75 mm wide
734-326
734-327
734-328
734-329
734-430
734-431
2022-103/000-039
No. of poles​​
Item no.​​
Pack. unit​
1-conductor female plug, with coding fingers,
green-yellow, blue, gray, ​
50
5 poles​​
2022-105/000-038
50
1-conductor female plug, with coding fingers,
gray, blue, green-yellow, ​
50
5 poles​​
2022-105/000-039
50
Appropriate marking systems: WMB/Marking Strips (see pages 96 -101)
Insulation stop, 5 pcs / Strip,
0.25 - 0.5 mm²
light gray
2002-171
0.75 - 1 mm²
dark gray
2002-172
3 poles​​
2022-103/000-038
AWG 22 – 12​​
600 V, 20 A U
L 10 – 12 mm / 0.43 in​​
1-conductor female plug, with coding fingers,
green-yellow, blue, gray, ​
3 poles​​
0.25 – 2.5 (4) mm2
690 V/6 kV/3 ➊
IN 24 (32) A*​​
Module width 5.2 mm / 0.205 in​​
L 10 – 12 mm / 0.43 in​​
1-conductor female plug, with coding fingers,
green-yellow, gray,
​
3 poles​​
2022-103/000-036
50
3 poles​​
mm2
Module width 5.2 mm / 0.205 in​​
L 10 – 12 mm / 0.43 in​​
No. of poles​​
0.25 – 2.5 (4)
690 V/6 kV/3
IN 24 (32) A*​​
WMB Multi marking card
10 strips with 10 markers each
5 - 5.2 mm
blank
793-5501
WMB Inline, blank,
5 - 5.2 mm
1,500 WMB-markers on 5 mm roll
white
2009-115
Continuous marking strip, blank
11 mm wide,
50 m roll
white
5
1
100 (4x25)
100 (4x25)
100 (4x25)
100 (4x25)
50 (2x25)
50 (2x25)
91
?
Separator Plates, Oversized
Separator plates, oversized
suitable for 2002 Series Terminal Blocks​
Separator plates, oversized
suitable for 2004 Series Terminal Blocks​
Separator plates, oversized
suitable for 2006 Series Terminal Blocks​
Item no.​
Pack-unit pcs.
Item no.
Pack-unit pcs.​
Item no.​
Pack-unit pcs.
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 2-conductor terminal blocks​
orange​
2002-1294
100
gray​
2002-1293
100
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 2-conductor terminal blocks​
orange​
2004-1294
100
gray​
2004-1293
100
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 2-conductor terminal blocks​
orange​
2006-1294
100
gray​
2006-1293
100
Item no.​
Pack-unit pcs.
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 3-conductor terminal blocks​
orange​
2002-1394
100
gray​
2002-1393
100
Item no.​
Pack-unit pcs.
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 3-conductor terminal blocks​
orange​
2004-1394
100
gray​
2004-1393
100
Item no.​
Pack-unit pcs.
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 3-conductor terminal blocks​
orange​
2006-1394
100
gray​
2006-1393
100
Note: Exe/Exi separators can be used with all TOPJOB®S series
Item no.​
Pack-unit pcs.
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 4-conductor terminal blocks​
orange​
2002-1494
100
gray​
2002-1493
100
92
Item no.​
Pack-unit pcs.
Separator plate, oversized, 0.8 mm/ 0.031 in thick
suitable for 4-conductor terminal blocks​
orange​
2004-1494
100
gray​
2004-1493
100
Item no.​
Pack-unit pcs.
Exe/Exi, separator, 3 mm/ .117 in thick
orange
90 mm wide
209-190
100
120 mm wide​
209-191
100
125.5 mm wide
209-192*
50
*(shown above)
Mounting Accessories
Carrier Rails and Stickers for Operating Instructions
Rail end cap
Adjustable height group marker carriers
<__
28‑mm / __>
1.10 in
End stop
Screwdrivers
with partially insulated shaft
for optimum handling
in terminal blocks
<__ 45‑mm /1.77‑in __>
ItemPack.-unit
No.pcs
Rail end cap,
for DIN 35 rail (7.5 mm high)
209-109 50 (2 x 25)
ItemPack.-unit
No.pcs
Adjustable height group marker carriers,
249-119 50 (2 x 25)
Marker card . . ., from white cardboard,
for self-marking, 100 markers per sheet
209-113
1 sheet
. . . or self-adhesive label,
for self-marking, 7 x 25 pcs per sheet
210-345
1 sheet
Protection cover, transparent
209-114 50
End stop, for DIN 35 rail
6 mm/0.236 in wide249-116
100 (4 x 25)
10 mm/0.394 in wide249-117
50 (2 x 25)
ItemPack.-unit
No.pcs
Screwdriver with partially insulated shaft,
type 1, blade 2.5 x 0.4 mm /0.098 in x 0.016 in,
suitable for series 2001, 2000
210-719
1
type 2, blade 3.5 x 0.5 mm /0.137 in x 0.020 in,
suitable for Series 2002, 2004
210-720
1
type 3, blade 5.5 x 0.8 mm /0.217 in x 0.031 in,
suitable for Series 2006, 2010, 2016
210-721
1
Screwdrivers with partially insulated shaft, – set –
types 1 – 3 210-722
1
Operating sticker
for TOPJOB®S jumpers
Size 80 mm x 101 mm
Size 80 mm x 101 mm
1
3 4
Operating sticker
for TOPJOB®S rail-mounted terminal blocks
1 2 3 4
Carrier rail 35 x 7.5 mm,
1 mm/0.039 in thick,
acc. to EN 60715,
Steel, IN 76 A (referred to a length of 1 m)
max.
500V
U2 300V
TOPJOB®S tool with partially insulated shaft
suitable for Series 2003, 2005
2009-310
1
0210-0400/2000-0002
0210- 0400/2000-0001
<_ 36 _>
> <
5,2
<___ 27 ___>
1
> <_
> 7,5 <
-20%
2001/2002/ 2004/ 2006/ 2010 /2016
<____ 35 ____>
(_25_)
2000 ±1,5
ItemPack.-unit
No.pcs
2 m /6’6” long
Steel rail 35‑x‑7.5 mm, 1‑mm/0.039 in thick
unslotted210-113 10
Steel rail 35‑x‑7.5 mm, 1‑mm/0.039 in thick
210-112
10
slotted
ItemPack.-unit
No.pcs
Operating sticker,
for TOPJOB®S rail-mounted terminal blocks
Series 2001/2002/2004/2006/2010/2016
210-400/2000-0001 100
ItemPack.-unit
No.pcs
Operating sticker,
for TOPJOB®S jumpers
Series 2001/2002/2004/2006/2010/2016
210-400/2000-0002
100
93
?
Ferrules for Rail-Mounted Terminal Blocks and Crimping Tools
Insulated ferrules,
electrolytic copper, electro-tin plated,
acc. to DIN 46228, part 4/09.90
<
_ D1 >
_
<__ D __>
< D2 <
Dimensions (in mm)
<____ L1 ____>
<___________ L __________>
Insulated
ferrules
suitable for
series
2001 – 2002
2001 – 2002
2002 – 2006
2001 – 2002
2002 – 2006
2001 – 2002
2002 – 2006
2010 – 2016
2002
2002 – 2006
2010 – 2016
2004 – 2006
2010 – 2016
2006
2010 – 2016
2010 – 2016
2016
Sleeve for
Color
Stripped
L
L1
D
D1
D2
Item
mm2 AWG length mmmmNo
0.5 22 white 12
16 10 3.12.61.0 216-241
0.7520 gray 12
16 10 3.32.81.2 216-242
0.7520 gray 14
18 12 3.32.81.2 216-262
1.0 18 red 12
16 10 3.53.01.4 216-243
1.0 18 red 14
18 12 3.53.01.4 216-263
1.5 16 black 12
16 10 4.03.51.7 216-244
1.5 16 black 14
18 12 4.03.51.7 216-264
1.5 16 black 20
24 18 4.03.51.7 216-284
2.5 14 blue 12
17 10 4.74.22.2 216-246
2.5 14 blue 14
19 12 4.74.22.2 216-266
2.5 14 blue 20
25 18 4.74.22.2 216-286
4.0 12 gray 14
20 12 5.44.82.8 216-267
4.0 12 gray 20
26 18 5.44.82.8 216-287
6.0 10 yellow14
20 12 6.96.33.5 216-208
6.0 10 yellow20
26 18 6.96.33.5 216-288
10.0 8 red 20
28 18 8.47.64.5 216-289
16.0 6 blue 23
28 18 9.68.85.8 216-210
Pack.-unit
pcs
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
500
500
500
500
500
500
Notes: Twin ferrules are available. Contact WAGO for more information.
ith the Variocrimp 4 built-in crimping pressure
W
plates control the crimping force automatically
for the conductor cross section used.
With the Variocrimp 16 it is necessary to select
the wire gauge on the tool before crimping.
● Each tool has only one crimping station for all
the wire sizes handled.
● Uniform compact crimping from all four sides
for high conductor retention.
● No need to center the conductor in the ferrule
sleeve.
● Conductor and ferrule insertion possible from
both sides (for left- and right handed).
● Built-in ratchet to guarantee complete crimping
every time.
● Tools open automatically after crimping
­operation is complete.
● Comfortable handles for operator.
●
94
Item
Pack. unit
No.pcs
Variocrimp 4,
Crimping tool for ferrules
insulated and uninsulated,
0.25 mm2 – 4 mm2 / AWG 24 – 12
206-204
1
weight 400 g / 0.882 lbs
Item
Pack. unit
No.pcs
Variocrimp 16,
Crimping tool for ferrules
insulated and uninsulated,
6 mm2 – 16 mm2 / AWG 10 – 6
206-216
1
weight 580 g / 1.28 lbs
?
Overview of Connectable Ferrules from 0.5 mm2
Series
Rated crosssection in mm2
0.5
mm2
0.75
mm2
1
mm2
1.5
mm2
2001 0.25 – 1.5 (2.5) 216-241 216-242 216-243 216-244
2.5
mm2
4
mm2
6
mm2
10
mm2
16
mm2
––
––
––
––
––
2002
0.25 – 2.5 (4) 216-241 216-242 216-243 216-244
216-246
––
––
––
––
2003
0.25 – 2.5 (4) 216-241 216-242 216-243 216-244
216-246
––
––
––
––
2004
0.5 – 4 (6)
––
216-262 216-263 216-264
216-266
216-267
––
––
––
2005
0.5 – 4 (6)
––
216-262 216-263 216-264
216-266
216-267
––
––
––
2006
0.5 – 6 (10)
––
216-262 216-263 216-264
216-266
216-267 216-208
––
––
2010
0.5 – 10 (16)
––
––
216-286
216-287 216-288 216-289
2016
0.5 – 16 (25)
––
––
216-286
216-287 216-288 216-289 216-210
216-263 216-284
––
216-284
––
TOPJOB®S
Overview of Ferrules that can be Connected Directly (Push In)
Series Rated cross section in mm2
0.5
mm2
2001 0.25 – 1.5 (2.5)
––
2002
0.25 – 2.5 (4)
2003
0.75
mm2
1
mm2
1.5
mm2
2.5
mm2
4
mm2
6
mm2
10
mm2
16
mm2
216-242 216-243 216-244
––
––
––
––
––
––
216-242 216-243 216-244
216-246
––
––
––
––
0.25 – 2.5 (4)
––
216-242 216-243 216-244
216-246
––
––
––
––
2004
0.5 – 4 (6)
––
216-262 216-263 216-264
216-266
216-267
––
––
––
2005
0.5 – 4 (6)
––
216-262 216-263 216-264
216-266
216-267
––
––
––
2006
0.5 – 6 (10)
––
––
––
216-264
216-266
216-267 216-208
––
––
2010
0.5 – 10 (16)
––
––
––
––
216-286
216-287 216-288 216-289
2016
0.5 – 16 (25)
––
––
––
––
216-286
216-287 216-288 216-289 216-210
––
95
Convenient Marking
With WMB Inline or Continuous Marking Strip – Quick and Easy
3M - PL 300 printer
96
The smartPRINTERTM offers quick
and economical marking using the
continuous marking strip...multiple
lines of text is even possible.
Cost-Efficient and Fast Marking
Thermal transfer printer
smartPRINTERTM
Thermal printer
3M-PL300
Item
No.
Thermal transfer printerr, smartPRINTERTM
Resolution 300 dpi
258-5000
Item
No.
3M-PL300/thermal printer
Resolution 180 dpi
258-6000
Includes: smartSCRIPT software, roller for marking strips,
roller for marking WMB Inline (5mm), ink ribbon, 1 roll
continuous marking strip and 1 roll WMB inline markers
Marking material options:
Polyester strips, 11mm wide –
5.5m long in cartridge
211-611
Marking strip, white
for center marking
WMB Inline
TOPJOB®S group marker carriers
TOPJOB®S marking adapters for WMB
Module width 5 mm / 0. 197 in
Module width 10 mm / 0.394 in
Module width 15 mm / 0.59 1 in
markers and continuous marking strip
for marker cards and self-adhesive marker cards
ItemPack.-unit
No.pcs
Marker strip, white, plain
for center marking
11 mm wide, on roll
2009-110
50 m
1
WMB Inline, pitch 5 mm/ stretchable
5 mm – 5.2 mm, on roll
white, 1,500 markers 2009-1151
WMB Inline, pitch 4 mm/ stretchable
4 mm – 4.2 mm, on roll
white, 2,000 markers 2009-1141
ItemPack.-unit
No.pcs
TOPJOB®S group marker carrier,
snap-on type for jumper slot
5 mm/0.197 in wide2009-191
50
50
10 mm/0.394 in wide2009-192
50
15 mm/0.591 in wide2009-193
suitable for:
WAGO Multi marking system WMB,
miniature WSB Quick marking system,
marker strips, 11 mm wide
ItemPack.-unit
No.pcs
Marking adapter
for lateral marker receptacle
gray
2009-198
200
2002-161
100
Marking adapter
for jumper slots
gray
for marker cards and self-adhesive marker cards
2009-196
50
97
WAGO Multi Marking System WMB – Horizontal
for 3.5 mm, 4 - 4.2 mm, 5 mm and wider terminal blocks
Horizontal marking
Consecutive numbers each strip
10 strips w ith 10 markers per card
for terminal block widths
5 - 17.5 mm,
5 - 5.2 mm, 4 - 4.2 mm and 3.5 mm
1 Individual marking of 2002, 2022, 2004, 2006, 2010
and 2016 series terminal blocks
2 For continuous marking of 2002 and 2022 series terminal blocks. Individual marking of terminal blocks larger
than 5/5.2 mm
3 For continuous marking of 2001 series terminal blocks
4 For continuous marking of 2000 series terminal blocks
Marker Width
5 - 5.2 mm 2
Marker Width
4 - 4.2 mm 3
Marker Width
3.5 mm 4
1 . . . 10 (10x)
11 . . . 20 (10x)
21 . . . 30 (10x)
31 . . . 40 (10x)
41 . . . 50 (10x)
51 . . . 60 (10x)
61 . . . 70 (10x)
71 . . . 80 (10x)
81 . . . 90 (10x)
91 . . . 100 (10x)
Marker Width
5 mm 1
793-502
793-503
793-504
793-505
793-506
793-569
793-570
793-571
793-572
793-573
793-5502
793-5503
793-5504
793-5505
793-5506
793-5569
793-5570
793-5571
793-5572
793-5573
793-4502
793-4503
793-4504
793-4505
793-4506
793-4569
793-4570
793-4571
793-4572
793-4573
793-3502
793-3503
793-3504
793-3505
793-3506
–
–
–
–
–
1 . . . 50 (2x)
51 . . . 100 (2x)
101 . . . 150 (2x)
151 . . . 200 (2x)
793-566
793-507
793-508
793-509
793-5566
793-5507
793-5508
793-5509
793-4566
793-4507
793-4508
793-4509
793-3566
793-3507
793-3508
793-3509
201 . . . 300 (1x)
301 . . . 400 (1x)
401 . . . 500 (1x)
501 . . . 600 (1x)
601 . . . 700 (1x)
701 . . . 800 (1x)
801 . . . 900 (1x)
901 . . .1000 (1x)
793-510
793-511
793-512
793-513
793-514
793-515
793-516
793-517
793-5510
793-5511
793-5512
793-5513
793-5514
793-5515
793-5516
793-5517
793-4510
793-4511
793-4512
793-4513
793-4514
793-4515
793-4516
793-4517
–
–
–
–
–
–
–
–
1 . . . 9, ; (10x)
793-565
793-5565
793-4565
793-3565
for double deck terminal blocks
1, 3, 5, , . . . 99 and 2, 4, 6, . . . 100 (1x)
793-599
793-5599
793-5599
–
794-557
794-5557
–
–
794-558
794-5558
–
–
Marking
per card
for triple deck terminal blocks
1, 4, 7, . . . 88 and 2, 5, 8, . . . 89 and 3, 6, 9, . . . 90
and 91, 94, 97, 92, 95, 98, 93, 96, 99, ; (1x)
100, 103, 106, . . . 187 and 101, 104, 107, . . . 188
and 102, 105, 108, . . . 189 and 190, 193, 196, 191,
194, 197, 192, 195, 198, ; (1x)
Stretching of a strip,
stretchable from 4 mm up to 4.2 mm for series 2001
stretchable from 5 mm up to 5.2 mm for series 2002
98
Separation of an individual marker from the strip,
for series 2002
WAGO Multi Marking System WMB – Vertical
for 3.5 mm, 4 - 4.2 mm, 5 mm and wider terminal blocks
Vertical marking
Consecutive numbers each strip
10 strips with 10 markers per card
for terminal block widths
5 - 17.5 mm,
5 - 5.2 mm, 4 - 4.2 mm and 3.5 mm
1 Individual marking of 2002, 2022, 2004, 2006, 2010
and 2016 series terminal blocks
2 For continuous marking of 2002 and 2022 series terminal blocks. Individual marking of terminal blocks larger
than 5/5.2 mm
3 For continuous marking of 2001 series terminal blocks
4 For continuous marking of 2000 series terminal blocks
Marker Width
5 - 5.2 mm 2
Marker Width
4 - 4.2 mm 3
Marker Width
3.5 mm 4
1 . . . 10 (10x)
11 . . . 20 (10x)
21 . . . 30 (10x)
31 . . . 40 (10x)
41 . . . 50 (10x)
51 . . . 60 (10x)
61 . . . 70 (10x)
71 . . . 80 (10x)
81 . . . 90 (10x)
91 . . . 100 (10x)
Marker Width
5 mm 1
793-602
793-603
793-604
793-605
793-606
794-601
794-602
794-603
794-604
794-605
793-5602
793-5603
793-5604
793-5605
793-5606
794-5601
794-5602
794-5603
794-5604
794-5605
793-4602
793-4603
793-4604
793-4605
793-4606
794-4601
794-4602
794-4603
794-4604
794-4605
on request
1 . . . 50 (2x)
51 . . . 100 (2x)
101 . . . 150 (2x)
151 . . . 200 (2x)
793-666
793-607
793-608
793-609
793-5666
793-5607
793-5608
793-5609
793-4666
793-4607
793-4608
793-4609
201 . . . 300 (1x)
301 . . . 400 (1x)
401 . . . 500 (1x)
501 . . . 600 (1x)
601 . . . 700 (1x)
701 . . . 800 (1x)
801 . . . 900 (1x)
901 . . .1000 (1x)
1001 . . .1100 (1x)
1101 . . .1200 (1x)
1201 . . .1300 (1x)
1301 . . .1400 (1x)
1401 . . .1500 (1x)
1501 . . .1600 (1x)
1601 . . .1700 (1x)
1701 . . .1800 (1x)
1801 . . .1900 (1x)
1901 . . .2000 (1x)
793-610
793-611
793-612
793-613
793-614
793-615
793-616
793-617
793-688
793-669
793-670
793-671
793-672
793-901
793-902
793-903
793-912
793-913
793-5610
793-5611
793-5612
793-5613
793-5614
793-5615
793-5616
793-5617
793-5688
793-5669
793-5670
793-5671
793-5672
793-5901
793-5902
793-5903
793-5912
793-5913
793-4610
793-4611
793-4612
793-4613
793-4614
793-4615
793-4616
793-4617
793-4688
793-4669
793-4670
793-4671
793-4672
793-4901
793-4902
793-4903
793-4912
793-4913
101, 101, 101, 102, . . .130, 130, 130 (1x)
131, 131, 131, 132, . . . 160, 160, 160 (1x)
793-667
793-668
793-5667
793-5668
793-4667
793-4668
for double deck terminal blocks
1, 3, 5, , . . . 99 and 2, 4, 6, . . . 100 (1x)
101, 103, 105, . . . 149 and 102, 104, 106, . . . 150 (2x)
793-669
793-900
793-5699
793-5900
793-4699
793-4900
794-657
794-5657
794-4657
794-658
794-5658
–
Marking
per card
for triple deck terminal blocks
1, 4, 7, . . . 88 and 2, 5, 8, . . . 89 and 3, 6, 9, . . . 90 and
91, 94, 97, 92, 95, 98, 93, 96, 99, ; (1x)
100, 103, 106, . . . 187 and 101, 104, 107, . . . 188 and
102, 105, 108, . . . 189 and 190, 193, 196, 191, 194,
197, 192, 195, 198, ; (1x)
99
Marker cards, plain
Marker strips
WMB Multi marking system
WMB Multi marking system
ItemPack.-unit
No.pcs
WMB Inline marking system
for 5 - 17.5 mm width, 10 strips with 10 markers per card
plain
ItemPack.-unit
No.pcs
WMB Inline marking system
for 5 - 5.2 mm width, 10 strips with 10 markers per card
plain
793-55015
793-5015
Marker cards in different colors:
yellow
793-501/000-002
red
793-501/000-005
blue
793-501/000-006
gray
793-501/000-007
orange
793-501/000-012
light green
793-501/000-017
green
793-501/000-023
violet
793-501/000-024
5
5
5
5
5
5
5
5
ItemPack.-unit
No.pcs
WMB Inline marking system
for 4 - 4.2 mm width, 10 strips with 10 markers per card
plain
793-45015
Marker cards in different colors:
yellow
793-5501/000-0025
red
793-5501/000-0055
blue
793-5501/000-0065
gray
793-5501/000-0075
orange
793-5501/000-0125
light green
793-5501/000-0175
green
793-5501/000-0235
violet
793-5501/000-0245
ItemPack.-unit
No.pcs
WMB multi marking system,
3.5 mm wide, 10 strips with 10 markers per card
plain
Marker cards in different colors:
yellow
793-4501/000-0025
red
793-4501/000-0055
blue
793-4501/000-0065
gray
793-4501/000-0075
orange
793-4501/000-0125
light green
793-4501/000-0175
green
793-4501/000-0235
violet
793-4501/000-0245
100
WSB Quick marking system
793-35011
ItemPack.-unit
No.pcs
Miniature WSB Quick marking system,
5 mm wide, 10 strips with 10 markers per card
plain
248-5015
Marker cards in different colors:
yellow
248-501/000-002
red
248-501/000-005
blue
248-501/000-006
gray
248-501/000-007
orange
248-501/000-012
light green
248-501/000-017
green
248-501/000-023
violet
248-501/000-024
5
5
5
5
5
5
5
5
Marker carriers for WCB Combi Marking System
Marking carriers
for 4 WCB markers
WCB Combi marking system
20 markers with identical
numbers/letters each tag
Item
No.
Pack.-unit
pcs
Marker carriers for 4 WCB markers
2009-184
suitable for terminal blocks with WMB marking
receptable
MarkingItem MarkingItem
per tag
No.
per tag
No.
plain
1 (20x)
2 (20x)
3 (20x)
4 (20x)
5 (20x)
6 (20x)
7 (20x)
8 (20x)
9 (20x)
0 (20x)
249-200
249-201
249-202
249-203
249-204
249-205
249-206
249-207
249-208
249-209
249-210
1...0 (2x)
249-239
1. (20x)
2. (20x)
3. (20x)
4. (20x)
5. (20x)
6. (20x)
7. (20x)
8. (20x)
9. (20x)
0. (20x)
249-241
249-242
249-243
249-244
249-245
249-246
249-247
249-248
249-249
249-250
+ (20x)
– (20x)
249-237
249-238
Pieces per packing unit: 10 tags
A (20x)
B (20x)
C (20x)
D (20x)
E (20x)
F (20x)
G (20x)
H (20x)
I (20x)
J (20x)
K (20x)
L (20x)
M (20x)
N (20x)
O (20x)
P (20x)
Q (20x)
R (20x)
S (20x)
T (20x)
U (20x)
V (20x)
W (20x)
X (20x)
Y (20x)
Z (20x)
249-211
249-212
249-213
249-214
249-215
249-216
249-217
249-218
249-219
249-220
249-221
249-222
249-223
249-224
249-225
249-226
249-227
249-228
249-229
249-230
249-231
249-232
249-233
249-234
249-235
249-236
Insert WCB Combi marker into marker carrier
...and insert the marker carrier into the WMB
marking receptacle of the terminal block
101
Approvals
Item
Approval-
No.
No.
A list of approvals (update: catalog deadline) is provided on this page. Due to the numerous agencies and approvals
as well as the ever-increasing number of new products, our online catalog provides you with complete up-to-date
information at www.wago.com
Vol- Cur-Cross
tage rentSection
V AAWG/mm2
UL –
U
Underwriters Laboratories
USA
2001-120 . E45172
600 15
2001-1207E45172
2001-130 . E45172
600 15
2001-1307E45172
2001-140.E45172
600 15
2001-1407E45172
2002-120 . E45172
600 20
2002-1207E45172
2002-130 . E45172
600 20
2002-1307E45172
2002-140.E45172
600 20
2002-1407E45172
2002-22 . . E45172
300/600 20/5
2002-32 . . E45172
300/600 20/5
2004-120 . E45172
600 30
2004-1207E45172
2004-130 . E45172
600 30
2004-1307E45172
2004-140.E45172
600 30
2004-1407E45172
2006-120 . E45172
600 50
2006-1207E45172
2006-130 . E45172
600 50
2006-1307E45172
2016-120 . E45172
600 85
2016-1207E45172
2016-130 . E45172
600 85
2016-1307E45172
22-14
22-14
22-14
22-14
22-14
22-14
22-12
22-12
22-12
22-12
22-12
22-12
22-12
22-12
20-10
20-10
20-10
20-10
20-10
20-10
20-8
20-8
20-8
20-8
20-4
20-4
20-4
20-4
K
N.V. tot Keuring van Elektro
technische Materialien,
Netherlands
2001-120 . NL2031569.05
800 18
2001-1207NL2031569.05
2001-130 . NL2031569.05
800 18
2001-1307NL2031569.05
2001-140 . NL2031569.05
800 18
2001-1407NL2031569.05
2002-120 . NL2086303.01
800 24
2002-1207NL2086303.01
2002-130 . NL2086303.01
800 24
2002-1307NL2086303.01
2002-140 . NL2086303.01
800 24
2002-1407NL2086303.01
2002-22 . . NL2086303.01
500 24
2002-32 . . NL2086303.01
500 24
2003-7641 NL2079570.51 250/400 32
2003-7642 NL2079570.51
400 32
2003-7645 NL2079570.51 250/400 32
2003-7646 NL2079570.51 250/400 32
2003-7649 NL2079570.51
400 32
2004-120 . NL2031569.08
800 32
2004-1207 NL2031569.08
2004-130 . NL2031569.08
800 32
2004-1307 NL2031569.08
2004-140 . NL2031569.08
800 32
2004-1407 NL2031569.08
2006-120 . NL2031569.03
800 41
2006-1207NL2031569.03
2006-130 . NL2031569.03
800 41
2006-1307NL2031569.03
2010-120 . NL2031569.02
800 57
2010-1207NL2031569.02
2010-130 . NL2031569.02
800 57
2010-1307 NL2031569.02
2016-120 . NL2031569.04
800 76
2016-1207 NL2031569.04
2016-130 . NL2031569.04
800 76
2016-1307 NL2031569.04
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,2-4
0,2-4
0,25-4
0,25-4
0,25-4
0,25-4
0,25-4
0,5-6
0,5-6
0,5-6
0,5-6
0,5-6
0,5-6
0,5-10
0,5-10
0,5-10
0,5-10
0,5-16
0,5-16
0,5-16
0,5-16
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
CSA – Canadian Standard
2
Association
Canada
2001-120 .154112-1645434 600 15
2001-1207 154112-1645434
2001-130 .154112-1645434 600 15
2001-1307 154112-1645434
2001-140 .154112-1645434 600 15
2001-1407 154112-1645434
2002-120 .154112-1536069 600 20
2002-1207 154112-1536069
2002-130 .154112-1536069 600 20
2002-1307 154112-1536069
2002-140 .154112-1536069 600 20
2002-1407 154112-1536069
2004-120 .154112-1645435 600 30
2004-1207 154112-1645435
2004-130 .154112-1645435 600 30
2004-1307 154112-1645435
2004-140 .154112-1645435 600 30
2004-1407 154112-1645435
2006-120 .154112-1543858 600 50
2006-1207 154112-1543858
2006-130 .154112-1543858 600 50
2006-1307 154112-1543858
2010-120 .154112-1645436 600 65
2010-1207 154112-1645436
102
22-14
22-14
22-14
22-14
22-14
22-14
22-12
22-12
22-12
22-12
22-12
22-12
20-10
20-10
20-10
20-10
20-10
20-10
20-8
20-8
20-8
20-8
20-6
20-6
Item
Approval-
No.
No.
Vol- Cur-Cross
tage rentSection
V AAWG/mm2
2010-130 .154112-1645436 600 65
2010-1307 154112-1645436
2016-120 .154112-1579112 600 85
2016-1207 154112-1579112
2016-130 .154112-1579112 600 85
2016-1307 154112-1579112
0
g
20-6
20-6
20-4
20-4
20-4
20-4
f
LR –
Lloyd’s Register of Shipping
Great Britain
2002-120 . 91/20112(E3)
800 24
2002-120791/20112(E3)
2002-130 . 91/20112(E3)
800 24
2002-130791/20112(E3)
2002-140 . 91/20112(E3)
800 24
2002-140791/20112(E3)
2006-120 . 91/20112(E3)
800 41
2006-120791/20112(E3)
2006-130 . 91/20112(E3)
800 41
2006-130791/20112(E3)
2016-120 . 91/20112(E3)
800 76
2016-1207 91/20112(E3)
2016-130 . 91/20112(E3)
800 76
2016-1307 91/20112(E3)
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-10
0,5-10
0,5-10
0,5-10
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
GL – Germanischer Lloyd
Germany
2002-120 . 91/20112(E3)
800 24
2002-120791/20112(E3)
2002-130 . 91/20112(E3)
800 24
2002-130791/20112(E3)
2002-140 . 91/20112(E3)
800 24
2002-140791/20112(E3)
2006-120 . 91/20112(E3)
800 41
2006-120791/20112(E3)
2006-130 . 91/20112(E3)
800 41
2006-130791/20112(E3)
2016-120 . 91/20112(E3)
800 76
2016-1207 91/20112(E3)
2016-130 . 91/20112(E3)
800 76
2016-1307 91/20112(E3)
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-10
0,5-10
0,5-10
0,5-10
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
DNV – Det Norske Veritas
Denmark
2002-120 . E7570
800 24
2002-1207E7570
2002-130 . E7570
800 24
2002-1307E7570
2002-140 . E7570
800 24
2002-1407E7570
2006-120 . E7570
800 41
2006-1207E7570
2006-130 . E7570
800 41
2006-1307E7570
2016-120 . E7570
800 76
2016-1207 E7570
2016-130 . E7570
800 76
2016-1307 E7570
ABS
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-10
0,5-10
0,5-10
0,5-16
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
ABS – American Bureau
of Shipping
USA
2001-120 . 05-HG476175/1-PDA800 18
2001-120705-HG476175/1-PDA
2001-130 . 05-HG476175/1-PDA800 18
2001-130705-HG476175/1-PDA
2001-140 . 05-HG476175/1-PDA800 18
2001-140705-HG476175/1-PDA
2002-120 . 05-HG476175/1-PDA800 24
2002-120705-HG476175/1-PDA
2002-130 . 05-HG476175/1-PDA800 24
2002-130705-HG476175/1-PDA
2002-140 . 05-HG476175/1-PDA800 24
2002-140705-HG476175/1-PDA
2004-120 . 05-HG476175/1-PDA800 32
2004-120705-HG476175/1-PDA
2004-130 . 05-HG476175/1-PDA800 32
2004-130705-HG476175/1-PDA
2004-140 . 05-HG476175/1-PDA800 32
2004-140705-HG476175/1-PDA
2006-120 . 05-HG476175/1-PDA800 41
2006-120705-HG476175/1-PDA
2006-130 . 05-HG476175/1-PDA800 41
2006-130705-HG476175/1-PDA
2010-120 . 05-HG476175/1-PDA800 57
2010-120705-HG476175/1-PDA
2010-130 . 05-HG476175/1-PDA800 57
2010-130705-HG476175/1-PDA
2016-120 . 05-HG476175/1-PDA800 76
2016-1207 05-HG476175/1-PDA
2016-130 . 05-HG476175/1-PDA800 76
2016-1307 05-HG476175/1-PDA
Item
Approval-
No.
No.
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-4
0,5-6
0,5-6
0,5-6
0,5-6
0,5-6
0,5-6
0,5-16
0,5-16
0,5-16
0,5-16
0,5-16
0,5-16
0,5-16
0,5-16
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
Vol- Cur-Cross
tage rentSection
V AAWG/mm2
CENELEC CERTIFICATION
AGREEMENT
CCA-NL –
N.V. tot Keuring van Elektrotechnische Materialien,
Netherlands
According to the CENELEC Certification Agreement,
the CCA certificate is recognized in the following
European countries:
Belgium, Denmark, Germany, Greece, Spain, France,
Ireland, Italy, Luxembourg, Netherlands, Austria,
Portugal, Finland, Sweden, Great Britain, Czech
Republic, Estonia, Cyprus, Latvia, Lithuania, Hungary,
Malta, Poland, Slovenia, Slovakia
2001-130 . NL5724
800 18
2001-1307NL5724
2001-140 . NL5724
800 18
2001-1407NL5724
2002-120 . NL5851
800 24
2002-1207NL5851
2002-130 . NL5851
800 24
2002-1307NL5851
2002-140 . NL5851
800 24
2002-1407NL5851
2002-22 . . NL5851
500 24
2002-32 . . NL5851
500 24
2003-7641NL5828
250/400 32
2003-7642NL5828
400 32
2003-7645NL5828
250/400 32
2003-7646NL5828
250/400 32
2003-7649NL5828
2004-120 . NL5725
800 32
2004-1207NL5725
2004-130 . NL5725
800 32
2004-1307NL5725
2004-140 . NL5725
800 32
2004-1407NL5725
2006-120 . NL5551
800 41
2006-1207NL5551
2006-130 . NL5551
800 41
2006-1307NL5551
2010-120 . NL5755
800 57
2010-1207NL5755
2010-130 . NL5755
800 57
2010-1307NL5755
2016-120 . NL5555
800 76
2016-1207 NL5555
2016-130 . NL5555
800 76
2016-1307 NL5555
0,5-2,5
0,5-2,5
0,5-2,5
0,5-2,5
0,2-4
0,2-4
0,2-4
0,2-4
0,2-4
0,2-4
0,2-4
0,2-4
0,25-4
0,25-4
0,25-4
0,25-4
0,25-4
0,5-6
0,5-6
0,5-6
0,5-6
0,5-6
0,5-6
0,5-10
0,5-10
0,5-10
0,5-10
0,5-16
0,5-16
0,5-16
0,5-16
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
0,5-25 “f“
PBundesanstalt
Germany
PTB Physikalisch Technische
EEx e II
2001-120 .PTB05Atex1094U 550 16 0,5-2,5
with push-in type jumper bar max 17 A
2001-120 .IECEx
PTB05.0034U 550160,5-2,5
with push-in type jumper bar max 17 A
2001-1207 PTB05Atex1094U 0,5-2,5
2001-1207 IECExPTB05.0034U 0,5-2,5
2001-130 .PTB05Atex1094U 550 16 0,5-2,5
with push-in type jumper bar 17 A
2001-130 .IECEx
PTB05.0034U 550160,5-2,5
with push-in type jumper bar 17 A
2001-1307 PTB05Atex1094U 0,5-2,5
2001-1307 IECExPTB05.0034U 0,5-2,5
2001-140 .PTB05Atex1094U 550 16 0,5-2,5
with push-in type jumper bar 17 A
2001-140 .IECEx
PTB05.0034U 550160,5-2,5
with push-in type jumper bar 17 A
2001-1407 PTB05Atex1094U 0,5-2,5
2001-1407 IECExPTB03.0004U 0,5-2,5
2002-120 .PTB03Atex1162U 550 22 0,2-4
with push-in type jumper bar 20 A
2002-120 .IECEx
PTB03.0004U 550220,2-4
with push-in type jumper bar 20 A
2002-1207 PTB03Atex1162U 0,2-4
2002-1207 IECExPTB03.0004U 0,2-4
2002-130 .PTB03Atex1162U 550 22 0,2-4
with push-in type jumper bar 20 A
2002-130 .IECEx
PTB03.0004U 550220,2-4
with push-in type jumper bar 20 A
2002-1307 PTB03Atex1162U 0,2-4
2002-1307 IECExPTB03.0004U 0,2-4
2002-140 .PTB03Atex1162U 550 22 0,2-4
with push-in type jumper bar 20 A
2002-140 .IECEx
PTB03.0004U 550220,2-4
with push-in type jumper bar 20 A
2002-1407 PTB03Atex1162U 0,2-4
2002-1407 IECExPTB03.0004U 0,2-4
2004-120 .PTB05Atex1095U 550 30 0,5-6
with push-in type jumper bar 30 A
2004-120 .IECEx
Item
Approval-
No.
No.
Vol- Cur-Cross
tage rentSection
V AAWG/mm2
PTB05.0033U 550300,5-6
with push-in type jumper bar max 30 A
2004-1207 PTB05Atex1095U 0,5-6
2004-1207 IECExPTB05.0033U 0,5-6
2004-130 .PTB05Atex1095U 550 30 0,5-6
with push-in type jumper bar max 30A
2004-130 .IECEx
PTB05.0033U 550300,5-6
with push-in type jumper bar max 30 A
2004-1307 PTB05Atex1095U 0,5-6
2004-1307 IECExPTB05.0033U 0,5-6
2004-140 .PTB05Atex1095U 550 30 0,5-6
with push-in type jumper bar max 30 A
2004-140 .IECEx
PTB05.0033U 550300,5-6
with push-in type jumper bar max 30 A
2004-1407 PTB05Atex1095U 0,5-6
2004-1407 IECExPTB05.0033U 0,5-6
2006-120 .PTB05Atex1030U 550 33 0,5-10
with push-in type jumper bar max 38 A
2006-120 .IECEx
PTB05.0014U 550330,5-10
with push-in type jumper bar max 38 A
2006-1207 PTB05Atex1030U 0,5-10
2006-1207 IECExPTB05.0014U 0,5-10
2006-130 .PTB05Atex1030U 550 33 0,5-10
with push-in type jumper bar max 36 A
2006-130 .IECEx
PTB05.0014U 550330,5-10
with push-in type jumper bar max 36 A
2006-1307 PTB05Atex1030U 0,5-10
2006-1307 IECExPTB05.0014U 0,5-10
2010-120 .PTB05Atex1070U 550 51 0,5-16
with push-in type jumper bar max 51 A
2010-120 .IECEx
PTB06.0003U 550510,5-16
with push-in type jumper bar max 51 A
2010-1207 PTB05Atex1070U 0,5-16
2010-1207 IECExPTB06.0003U 0,5-16
2010-130 .PTB05Atex1070U 550 50 0,5-16
with push-in type jumper bar max 50 A
2010-130 .IECEx
PTB06.0003U 550500,5-16
with push-in type jumper bar max 50 A
2010-1307 PTB05Atex1070U 0,5-16
2010-1307 IECExPTB06.0003U 0,5-16
2016-120 .PTB05Atex1031U 550 33 0,5-25
with push-in type jumper bar max 70 A
2016-120 .IECEx
PTB05.0015U 550330,5-25
with push-in type jumper bar max 70 A
2016-1207 PTB05Atex1031U 0,5-25
2016-1207 IECExPTB05.0015U 0,5-25
2016-130 .PTB05Atex1031U 550 33 0,5-25
with push-in type jumper bar max 67 A
2016-130 .IECEx
PTB05.0015U 550330,5-25
with push-in type jumper bar max 67 A
2016-1307 PTB05Atex1031U 0,5-25
2016-1307 IECExPTB05.0015U 0,5-25
c URus –
Y
Underwriters Laboratories
USA
2001-120 . E185892
550 15
2001-1207E185892
2001-130 . E185892
550 15
2001-1307E185892
2001-140 . E185892
550 15
2001-1407E185892
2002-120 . E185892
550 20
2002-1207E185892
2002-130 . E185892
550 20
2002-1307E185892
2002-140 . E185892
550 20
2002-1407E185892
2004-120 . E185892
550 30
2004-1207E185892
2004-130 . E185892
550 30
2004-1307E185892
2004-140 . E185892
550 30
2004-1407E185892
2006-120 . E185892
550 50
2006-1207E185892
2006-130 . E185892
550 50
2006-1307E185892
2016-120 . E185892
550 85
2016-1207E185892
2016-130 . E185892
550 85
2016-1307E185892
22-14
22-14
22-14
22-14
22-14
22-14
22-12
22-12
22-12
22-12
22-12
22-12
20-10
20-10
20-10
20-10
20-10
20-10
20-8
20-8
20-8
20-8
20-4
20-4
20-4
20-4
103
Germany
WAGO Kontakttechnik
Minden
Tel. ++49/571/887/0
Fax ++49/571/887/169
Austria
WAGO Kontakttechnik
Wien
Tel.++43/1/615/07/80
Fax++43/1/615/07/75
Belgium
WAGO Kontakttechnik
Zaventem
Tel.++32/2/7/17/90/90
Fax++32/2/7/17/90/99
51288667 0888-0832/0000-0309 Printed in the United States
WAGO Service Worldwide
China
WAGO ELECTRONIC Co. Ltd.
Tianjin
Tel ++86/22/59617688
Fax++86/22/59617668
England
WAGO, Ltd.
Rugby
Tel.++44/1788/568008
Fax++44/1788/568050
France
WAGO CONTACT S.A.
Paris
Tel.++33/148172590
Fax++33/148632520
Italy
WAGO ELETTRONICA SRL
Casalecchio di Reno (BO)
Tel.++39/051/6132112
Fax++39/051/6272174
Japan
WAGO Co. of JAPAN Ltd.
Tokyo
Tel.++81/3/5627/2050
Fax ++81/3/5627/2055
Poland
WAGO ELWAG sp. z o. o.
Wroclaw
Tel.++48/71/3604670/78
Fax++48/71/3604699
Singapore
WAGO Electronic Pte. Ltd.
Singapore
Tel.++65/62866776
Fax++65/62842425
Switzerland
WAGO CONTACT SA
Domdidier
Tel.++41/26/676/75/86
Fax++65/26/676/75/01
Mexico
WAGO Corporation
Queretaro
Tel. 001/800/309/5975
+ 52/442/221/5946
Fax + 52/442/221/5063
Canada
WAGO Corporation
Tel. 800/DIN Rail (346-7245)
Fax 262/255-3232
www.wago.ca
WAGO Corporation
N120 W19129 Freistadt Road
Germantown, Wisconsin 53022
Telephone: 800 / DIN Rail (346-7245)
Fax: 262 / 255-3232
[email protected]
www.wago.us