Crompton Switchboard Meters
Transcription
Crompton Switchboard Meters
Crompton Switchboard Meters Ana-Digi Meters: Rugged taut bank construction 3 1/2 digit LED display Wide selection of inputs Standard ANSI 4 1/2" switchboard mounting L • • • • 077-DI Ana-Digi Meter AC AMMETERS TRANSFORMER RATED (40/2000Hz) Digital accuracy ±0.1% ±1 counts, analog accuracy ±1%. Rating Scaling* Catalog No. 5A 5A 5A 5A 5A 5A 5A 0-20A 0-50A 0-100A 0-300A 0-400A 0-500A 0-1500A 077-DIBA-LSNG-C6-** 077-DIBA-LSNT-C6-** 077-DIBA-LSPK-C6-** 077-DIBA-LSRX-C6-** 077-DIBA-LSSC-C6-** 077-DIBA-LSSF-C6-** 077-DIBA-LSTC-C6-** Direct reading AC Ammeters also available, 1A to 10A. PHASE SHIFTING TRANSFORMERS AC VOLTMETERS TRANSFORMER RATED (40/2000HZ) Phase/ Wire Amp/ Volt Scale 3/3 3/4 3/4 120V 120V 69V To Suit To Suit To Suit Standard Case Catalog Number K-956-A-PR K-957-A-PR K-956-A-NZ 41⁄2" Square Flange Hi-Shock Case Catalog Number 857-956J-PR 857-957J-PR 857-956J-NZ Rating Scaling* Catalog No. 150V 150V 150V 150V 150V 0-300V 0-600V 0-750V 0-3000V 0-6000V 077-DIWA-PZRX-C6-** 077-DIWA-PZSJ-C6-** 077-DIWA-PZSM-C6-** 077-DIWA-PZUA-C6-** 077-DIWA-PZUP-C6-** ANALOG METERS For use with Wattmeters, when VAR measurement with external phase shifter is required Direct reading AC Voltmeters also available, 200mV to 600V. AC FREQUENCY METERS K Use 855 for 412⁄ " or 834⁄ " Case Self contained 110/130 Volt rating. Integral transducer AC POWER FACTOR METERS (BALANCED LOAD) 4 ⁄ " Square Flange Hi-Shock Case Catalog Number 1 2 Phase/ Wire Amp/ Volt Scale 1/2 1/2 3 / 3 or 4 3 / 3 or 4 3 / 3 or 4 3 / 3 or 4 3 / 3 or 4 5/120 5/240 5/120 5/208 5/240 5/480 5/600 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 0.5-1- 0.5 Standard Case Catalog Number + K-425A-QQAD + K-425A-QSAD + K-427A-QQAD + K-427A-QRAD + K-427A-QSAD K-427A-QTAD K-427A-QVAD 078-425J-QQAD 078-425J-QSAD 078-427J-QQAD 078-427J-QRAD 078-427J-QSAD 078-427J-QTAD 078-427J-QVAD K Use 077 for 412⁄ " Case and 079 for 834⁄ " Case + 077 UL Recognized and CSA Approved , 079 UL Recognized AC POWER FACTOR METERS (UNBALANCED LOAD) Phase/ Wire 3/3 3/3 Amp/ Volt 5/120 5/120 Scale Standard Case Catalog Number N/A N/A AC POWER FACTOR METERS – ROTATING IRON - 360° Amp/ Volt Scale 3 / 3 or 4 3 / 3 or 4 3/3 3/3 5/120 5/280 5/120 5/280 0-1-0 0-1-0 0-1-0 0-1-0 Standard Case Catalog Number K-136A-QQAB K-136A-QRAB K-132A-QQAB K-132A-QRAB Accuracy Scaling* Catalog No. 50Hz 55Hz 60Hz 60Hz 400Hz ±0.15 ±0.25 ±0.25 ±0.15 ±1.25 45-55Hz 45-65Hz 50-70Hz 55-65Hz 360-440Hz 077-DZLA-PNAG-AG 077-DZLA-PNAJ-AJ 077-DZLA-PNAL-AL 077-DZLA-PNAN-AN 077-DZLA-PNBI-BI Direct reading AC Ammeters also available, 1A to 10A. DC VOLTMETERS - DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%. Rating Scaling* Catalog No. 200mV 1V 5V 50V 150V 300V 0-200mV 0-1V 0-5V 0-50V 0-150V 0-300V 077-DIVA-KAKA-** 077-DIVA-LALA-** 077-DIVA-LSLS-** 077-DIVA-NTNT-** 077-DIVA-PZPZ-** 077-DIVA-RXRX-** 41⁄2" Square Flange Hi-Shock Case Catalog Number 0.5-1- 0.5 077-TFUA-QQAD 0.5-1- 0.5 077-TFUA-QQAD Phase/ Wire Center 41⁄2" Square Flange Hi-Shock Case Catalog Number 078-136J-QQAB 078-136J-QQAB 078-136J-QQAB 078-136J-QQAB K Use 077 for 41⁄2" Standard Case and 079 for 83 ⁄4 " Standard Case DC AMMETERS – DIRECT READING Digital accuracy ±0.5% ±1 counts, analog accuracy ±1%. Rating Scaling* Catalog No. 1mA 10mA 20mA 100mA 1A 0-1mA 0-10mA 0-20mA 0-100mA 0-1A 077-DIAA-FAFA-** 077-DIAA-GZGZ-** 077-DIAA-HFHF-** 077-DIAA-JRJR-** 077-DIAA-LALA-** ** POWER SUPPLY MU BD NR PR PS Z2 – – – – – – 12 Volts DC 24 Volts DC 48 Volts DC 120 Volts DC 125 Volts DC 130 Volts DC PO – 115 Volts AC PQ – 120 Volts AC RR – 240 Volts AC Many standard ranges not shown. *Custom scales and custom ranges on request. 54 Weschler Analog Edgewise and Panel Meters Type 252 edgewise instruments were designed specifically for the nuclear power industry. Their ruggedness and reliability make them an excellent choice for any control panel. These instruments incorporate the same taut-band suspension system that is used in the Weschler switchboard meters. They are available for direct measurement of standard electrical quantities, or in combination with transducers for measuring any other electrical or mechanical quantity that can be converted into a proportional electrical quantity. MODIFICATIONS AVAILABLE • Internal illumination • Non-glare window • Dual scale or rating • Straight fine tubular pointer • Offset, center, or suppressed zero • Gasketed construction The V252 & H252 Meters exceed the requirements for the 2% class specified in ANSI C39.1, and may be calibrated to 1% initial accuracy. They meet the flammability requirements of IEEE Standard 420-1973 and they have passed the seismic qualification tests under IEEE Standard 344-1987. Accuracy 1 1/2% of full scale deflection, 1% on special order. Waveform Compensation to 15% of third harmonic content. Instantaneous Overload 35x AC rating, 100x DC rating Voltage to Ground 1200V dc or peak ac, 800 volts ac rms Shielding Magnetically shielded Net Weight 1 1/2 pound Input self-contained DC 50µA to 50A 50mV to 750V AC 10mA to 20A 5V to 600V L 252 Edgewise L Transducer-type frequency meters, varmeter, wattmeters and power factor meters are available. MECHANISM ALSO AVAILABLE: 351/371 panel Airpax panel L The DC instrument is of the permanent magnet moving-coil type in a core magnet construction. For ac measurement the same mechanism is used, but rectifiers and an rms network are added. This design is practically immune to the effects of magnetic fields from adjacent conductors regardless of their orientation. L ANALOG METERS SPECIFICATIONS CONSTRUCTION All components are mounted on a plastic drawer which slides into a plastic case with a clear, curved window. The entire assembly is treated to be static free. The plastic is polycarbonate (ASTM D635) for impact strength and flame retardance. Pointer edge and dial markings are on the same arc so that there is no paralax error. Instruments may be stacked horizontally or vertically. See more information online at weschler.com/analog L 20/20 panel 55 L 221/251 Yokogawa Edgewise Switchboard Meters SPECIFICATIONS Accuracy Class Standard: L ±1.5% of FS span AC horizontal; ±2% for AC vertical Repeatability: ±2% of FS Operating Environment Temp.: -4°F to 150°F (-20°C to 65°C) Panel Mounting: Vertical or Horizontal Case Size: 2.294" H x 6.040" W x 5.765" D Panel Cutout: 1.791" x 5.695" AC Amperes Type: Iron-Vane Frequency: 40/70 Hz AC Volts Type: Iron-Vane Frequency: 60 Hz ANALOG METERS 180 DC AMPERES ORDERING GUIDE Rating Scale Vertical 1-5 mA ** 180 183 FYAA 8ABA 4-20 mA ** 180 183 HEAA 8ABA 10-50 mA ** 180 183 HXAA 8ABA DC Amperes Scale/ Terminal Rating Resistance Vertical 0-50 µA 4735 180 113 CYCY 0-100 µA 1480 180 113 DRDR 0-500 µA 226 180 113 EMEM 0-1 mA 40 180 113 FAFA 0-10 mA 5.0 180 113 GZGZ 0-500 mA 0.10 180 113 KMKM 0-1A 0.05 180 113 LALA 0-5A 0.010 180 113 LSLS 0-10A 0.005 180 113 MTMT 0-30A 0.001 180 113 NLNL 0-50A 0.001 180 113 NTNT DC Ammeters-50mV Shunt Rated Scale/ Terminal Rating Resistance Vertical 0-10 12.5 180 123 ECMT 0-30 12.5 180 123 ECNL 0-60 12.5 180 123 ECNW 0-100 12.5 180 123 ECPK 0-300 12.5 180 123 ECRL 0-500 12.5 180 123 ECSC 0-1KA 12.5 180 123 ECVA DC Volts-1000 Ω/Volt Rating/ Terminal Scale Resistance Vertical 0-1 1000 180 013 LALA 0-5 5000 180 013 LSLS 0-15 15000 180 013 NDND 0-50 50000 180 013 NTNT 0-150 150000 180 013 PZPZ 0-300 300000 180 013 RXRX 0-600 6000000 180 013 SJSJ 150-0-150 150000 180 014 PZPZ 300-0-300 300000 180 014 RXRX Horizontal 180 181 FYAA 8ABA 180 181 HEAA 8ABA 180 181 HXAA 8ABA AC AMPERES ORDERING GUIDE Horizontal 180 111 CYCY 180 111 DRDR 180 111 EMEM 180 111 FAFA 180 111 GZGZ 180 111 KMKM 180 111 LALA 180 111 LSLS 180 111 MTMT 180 111 NLNL 180 111 NTNT Horizontal 180 121 ECMT 180 121 ECNL 180 121 ECNW 180 121 ECPK 180 121 ECRL 180 121 ECSC 180 121 ECVA Horizontal 180 011 LALA 180 011 LSLS 180 011 NDND 180 011 NTNT 180 011 PZPZ 180 011 RXRX 180 011 SJSJ 180 012 PZPZ 180 012 RXRX AC Amperes—50/70 Hz, Iron Vane Scale Transformer ±2% Accuracy Rating Vertical 0-1A 180 143 LALA 0-5A Self180 143 LSLS 0-10A Contained 180 143 MTMT 0-20A 180 143 NGNG 0-30A 180 143 NLNL 0-50A 180 143 NTNT AC Amperes Transformer Rated, 5A 0-10A 10/5 180 143 LSMT 0-25A 25/5 180 143 LSNJ 0-50A 50/5 180 143 LSNT 0-75A 75/5 180 143 LSPB 0-100A 100/5 180 143 LSPK 0-150A 150/5 180 143 LSPZ 0-200A 200/5 180 143 LSRL 0-400A 400/5 180 143 LSSC 0-500A 500/5 180 143 LSSF 0-1 kA 1000/5 180 143 LSVA 0-1.2 kA 1200/5 180 143 LSVB 0-1.5 kA 1500/5 180 143 LSVC AC Voltmeters—60 Hz, Iron-Vane Type 0-150V 180 033 PZPZ 0-300V Self180 033 RXRX 0-500V Contained 180 033 SFSF 0-600V 180 033 SJSJ AC Voltmeters—Transformer-Rated, 150 Volt 0-300 240/120 180 033 PZRX 0-600 480/120 180 033 PZSJ 0-750 600/120 180 033 PZSM 0-3 KV 2400/120 180 033 PZVJ 0-5.25 KV 4200/120 180 033 PZVV 0-6 KV 4800/120 180 033 PZVX ±1.5% Accuracy Horizontal 180 141 LALA 180 141 LSLS 180 141 MTMT 180 141 NGNG 180 141 NLNL 180 141 NTNT 180 141 LSMT 180 141 LSNJ 180 141 LSNT 180 141 LSPB 180 141 LSPK 180 141 LSPZ 180 141 LSRL 180 141 LSSC 180 141 LSSF 180 141 LSVA 180 141 LSVB 180 141 LSVC 180 031 PZPZ 180 031 RXRX 180 031 SFSF 180 031 SJSJ 180 031 PZRX 180 031 PZSJ 180 031 PZSM 180 031 PZVJ 180 031 PZVV 180 031 PZVX 56 Yokogawa Edgewise Panel Meters • DC & AC Meters • Four Display Sizes: 1½", 2", 2½" and 3½" • Horizontal or Vertical Orientation • Meets ANSI C-39.1 • Shielded, Dust Tight Case (Model 185) • Stackable Mounting 185 - 3 Stack Mounted 280 Series - 3 Sizes ORDERING INFORMATION SPECIFICATIONS Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Orientation in box 2 . DC Ammeters - Zero Left, self-contained 1 11 2 CYCY 50 μA 1 11 2 DRDR 100 μA 1 11 2 EAEA 200 μA 1 11 2 EMEM 500 μA 1 11 2 FAFA 1 mA 1 11 2 FXFX 5 mA 1 11 2 GZGZ 10 mA 1 11 2 HFHF 20 mA 1 11 2 HJHJ 25 mA 1 11 2 HYHY 50 mA 1 11 2 JRJR 100 mA 1 11 2 KDKD 250 mA 1 11 2 KGKG 300 mA 1 11 2 KMKM 500 mA 1 11 2 LALA 1 Amp 1 11 2 LCLC 1.5 Amp 1 11 2 LELE 2 Amp 1 11 2 L J L J 3 Amp 1 11 2 LSLS 5 Amp 1 11 2 MTMT ** 10 Amp DC Ammeters - Zero Center, self-contained 1 11 2 CYCY 50-0-50 μA 1 11 2 DRDR 100-0-100 μA 1 11 2 EMEM 500-0-500 μA 1 11 2 FAFA 1-0-1 mA 1 11 2 FXFX 5-0-5 mA 1 11 2 HYHY 50-0-50 mA 1 11 2 LSLS 5-0-5 Amp DC Ammeters - Zero Left, 50mV Shunt Rated (Lead Resistance: 0.05–0.07Ω) Scale: 1 12 2 ECLA 1 Amp 1 12 2 ECLS 5 Amp 1 12 2 ECMT 10 Amp 1 12 2 ECNG 20 Amp 1 12 2 ECNT 50 Amp 1 12 2 ECRX 300 Amp 1 12 2 ECSF 500 Amp DC Ammeters - Zero Left, 100mV Shunt Rated (Lead Resistance: 0.05–0.07Ω) Scale: 1 12 2 GBLA 1 Amp 1 12 2 GBLS 5 Amp 1 12 2 GBMT 10 Amp 1 12 2 GMNG 20 Amp 1 12 2 GBNT 50 Amp 1 12 2 GBRX 300 Amp 1 12 2 GBSF 500 Amp Model 185 286 287 288 Nominal Size 2" 1½" 2½" 3½" Face Dimensions 0.92" x 2.258" 0.498" x 1.719" 0.673" x 2.645" 0.673" x 3.525" Bezel Dimensions 1.255" x 3.025" 0.77" x 2.075" 0.99" x 3.015" 0.99" x 3.89" Depth behind panel (incl studs) 3.3" 2.47" 3.42" 3.21" Cutout (single) 0.94" x 2.286" 0.5" x 1.650" 0.687" x 2.580" 0.687" x 3.460" Scale Length 1.78" 1.25" 1.93" 2.70" Dielectric Rating RMS 1800V 1500V 1500V 2600V Overshoot (max) 40% 25% 40% 40% Accuracy 2% DC, 3% AC @ 60Hz sine Response Time 2 sec for DC & 2.5 sec for AC, except 3 sec for μA Overload 185: Voltmeter 50% momentary, 20% sustained; Ammeter 900% momentary, 20% sustained 280 Series: DC Voltmeter 20% momentary & sustained; DC Ammeter 20% sustained DC Voltmeters - Zero Left 1000 Ω/ V 1 01 2 MTMT 10 Volts 1 01 2 NDND 15 Volts 1 01 2 NLNL 30 Volts 1 01 2 NTNT 50 Volts 1 01 2 PKPK 100 Volts 1 01 2 PZPZ 150 Volts 1 01 2 RLRL * 200 Volts 1 01 2 RXRX * 300 Volts DC Voltmeters - Zero Left, Rated 0-1mADC (for use with External Resistor—not included) Scale: 1 17 2 FASF 500 Volts 1 17 2 FASJ 600 Volts 1 17 2 FASM 750 Volts DC Voltmeters - Zero Center, self-contained (1000Ω/V except 2000Ω/V in Model 185) 1 01 2 NDND 15-0-15 Volts 1 01 2 NLNL 30-0-30 Volts 1 01 2 NTNT 50-0-50 Volts 150-0-150 Volts 1 01 2 PZPZ * ORDERING CODE GUIDE 1 2 Insert Model Number: 185 286 287 288 Insert Orientation: Zero Left Meters: 1 3 Zero Center Meters: 2 4 2" Edgewise 1½" Edgewise 2½" Edgewise 3½" Edgewise Horizontal Vertical Horizontal Vertical AC Voltmeters - Zero Left, Rectifier Type 1000 Ω/ V 1 05 2 MTMT 10 Volts 1 05 2 NDND 15 Volts 1 05 2 NLNL 30 Volts 1 05 2 NTNT 50 Volts 1 05 2 PKPK 100 Volts 1 05 2 PZPZ 150 Volts AC Ammeters - Zero Left, Rectifier Type 1 15 2 EMEM 500 μA 1 15 2 FAFA 1 mA 1 15 2 FXFX 5 mA 1 15 2 GZGZ 10 mA 1 15 2 HFHF 20 mA * Not available in 1½" ** Model 185 only OPTIONS Custom Scaling Non-standard Ranges Pointer Color Color Bands External Resistor Bezel Mounting Kit (Model 185) Stacked Mounting Bezel & mounting hardware included with 280 Series. Order separately for Model 185. 56a International Instruments Edgewise Panel Meters 3 1/2" and 6" Switchboard Meters • • • • • • Accuracy: ±1.5% (1151/1251) Single (1146/1151) or Dual Indicators (1246/1251) Rugged Construction Flush Stacking EMI Shielded Illumination Available ANALOG METERS Single/Dual Models 1151/1251 and 1146/1246 These meters were initially developed to meet the demanding specifications of the Atomic Energy Commission with respect to seismic qualifications, long-life and high accuracy. The resulting product line is the most rugged and reliable available. Models 1146 and 1246 are 3 1/2 inch meters, 1151 and 1251 6-inch models, both series of instruments manufactured of modern black plastic with a design compatibility that makes them perfectly suited for use together on the same panel board. Windows are tough clear Lexan®. ORDERING INFORMATION To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 1151-V-B-ACA 0-5/0-300 1251-V-B-ACV 0-150/0-600/B-ACA 0-5/0-400 Single A-B-C-D Dual A-B-C-D-C-D-C-D 1151 L 1251 L A – B – C – D A Model 1151 6" Single 1251 6" Dual 1146 3 1/2" Single 1246 3 1/2" Dual B Orientation H Horizontal V Vertical C Zero Position Horizontal Vertical L Left T Top C Center C Center R Right B Bottom D Standard Ranges, All Models AC Volts AC Amperes AC Milliamperes 0-10, 15, 25, 50, 150, 0-5 0-10, 100, 500 300, 500 DC Volts DC Amperes DC Microamperes DC Milliamperes 0-5, 10, 15, 0-1, 2, 5, 10, 0-50, 100, 200, 0-1, 2, 3, 4, 5, 25, 30, 50, 15, 25, 50, 300, 400, 500 10, 20, 50, 100, 100, 150, 200, 100*, 200* 200, 500, 4-20, 300, 500 10-50 *=50mV shunt rated SPECIFICATIONS Accuracy (% of FS) Repeatability Overload Response Time (sec. max.) Dielectric Strength (VRMS 60 Hz/1 min) Overshoot (max) Terminals (variations available) Scale length-inches (mm) Zero adjustment Pointer (other colors available) Weight (oz) 1146/1246 1151/1251 DC:2 AC:3 DC:1.5 AC:2.5 In Accordance with ANSI C39.1 In Accordance with ANSI C39.1 3.0 2.5 2600 40% 20% Threaded stud (10-32) Threaded stud (1/4-28) 2.7(68.6) 4.5(114.3) Yes Yes Red Delta 1146.8/1246:10 1151:25/1251:30 OPTIONS Factory Scaling—Custom Scaling (Specify) Factory Ranging Illumination—1151 & 1251 Only Adjustable Potentiometer—Voltmeters Only Zero Center Colored Bands—Price Per Color Also available: 1 1/2", 2 1/2" & 3 1/2" Edgewise Meters 57 International Instruments Thin Panel Meters ORDERING INFORMATION 4" Edgewise Meters • Compact Design for High Density Installations • Rugged Construction • Flush Stacking • EMI Shielded • Vertical or Horizontal Styles 1140 SPECIFICATIONS Accuracy: Repeatability: Overload: Response Time: Dielectric Strength: Overshoot: Terminals: Scale length: Zero adjustment: Pointer: Enclosure: Dimensions: Panel Cutout: 57a ±2% of full scale In Accordance with ANSI C39.1 In Accordance with ANSI C39.1 2 sec. max. 500VRMS 60 Hz/1 min 20% max Solder terminals (variations available) 3.7" Optional Red standard, other colors on reqest Steel housing with internal magnetic shield 0.515"W × 5.094"H × 4.52" behind panel 0.54" × 4.75" To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: 1140-V-B-DCmA 0-5/0-300 A – B – C – D / E A Model 1140 4" Ultra-Thin Edgewise B Orientation H Horizontal V Vertical C Zero Position Horizontal Vertical L Left T Top C Center C Center R Right B Bottom D Standard Ranges DC Volts DC Amps DC Microamps DC Milliamps 0-5, 10, 15, 0-1, 2, 5, 10, 0-50, 100, 200, 0-1, 2, 3, 4, 5, 25, 30, 50, 15, 25, 50, 300, 400, 500 10, 20, 50, 100, 100, 150, 200, 100*, 200* 200, 500, 4-20 300, 500 E Scale No entry: Scale matches meter range Custom: Specify scale and legend *=50mV shunt rated AC Voltmeters and Ammeters also available Yokogawa ToughMeter Analog Panel Meters Designed to Operate in Harsh Environments • Metal Case and Polycarbonate Window • Gasket Sealed Bezel • Dust & Moisture Protection on Terminals & Zero Adjust • IP66 Environmental Rating • Made in the USA NEW SPECIFICATIONS 2 1/2" 2.70" x 1.88" 2.23" 4-40 on 2.44" BCD x3 1 /4 - 28 Case Size Size (dia x depth) Cutout (dia) Mounting studs Terminals Accuracy Repeatability Overload Overshoot Response Time Vibration Sine Vibration Random Shock Operating Temperature 3 1/2" 3.50" x 1.88" 2.55" 4-40 on 3.16" BCD x3 1 /4 - 28 ±2% DC, ±3% AC ±2% 120% continuous 10% max 2 sec max 3G 10-80 Hz 3G (P&J), 5G (TB) 10-1000 Hz 50G -45 to +70°C Vibration, temperature and environmental specifications exceed ANSI C39.1 ANALOG METERS ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Model Code in box Order Example: 270220LSLS is taut band, 21/2" meter, 5VDC DC Ammeters - Zero Left 20 µA 50 µA 100 µA 1 mA L 270 1 2 1 2 1 2 1 2 00CFCF 00CYCY 00DRDR 00FAFA DC Ammeters - Zero Left, 50 mV Shunt Rated (Lead Res .05-.07Ω) 1 2 24ECNG 20 A 1 2 24ECNL 30 A 1 2 24ECNT 50 A 1 2 24ECPB 75 A 1 2 24ECPK 100 A 1 2 24ECPZ 150 A 1 2 24ECRL 200 A 1 2 24ECRS 250 A 1 2 24ECRX 300 A 1 2 24ECSC 400 A 1 2 24ECSF 500 A 1 2 24ECSJ 600 A 1 2 24ECSN 800 A 1 2 24ECVA 1.0 kA 1 2 24ECVC 1.5 kA 1 2 24ECVE 2.0 kA DC Voltmeters – Zero Left 5V 10 V 15 V 30 V 50 V 80 V 100 V 150 V 200 V 300 V 500 V 600 V 1 and Case Sizes in box AC Ammeters - Rectifier type 1 mA 500 mA AC Voltmeters – Rectifier type 150V 300V 500V 600V Frequency 45-55 Hz, 120 VAC 45-55 Hz, 208 VAC 45-55 Hz, 240 VAC 45-65 Hz, 120 VAC 45-65 Hz, 208 VAC 45-65 Hz, 240 VAC 55-65 Hz, 120 VAC 55-65 Hz, 208 VAC 55-65 Hz, 240 VAC 380-420 Hz, 120 VAC 380-420 Hz, 208 VAC 380-420 Hz, 240 VAC 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 . 10FAFA 00KMKM 30PZPZ 30RXRX 30SFSF 30SJSJ 50AGAG 50GGGG 50DGDG 50AJAJ 50GJGJ 50DJDJ 50ANAN 50GNGN 50DNDN 50BKBK 50HKHK 50EKEK ORDERING CODE GUIDE 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 20LSLS 20MTMT 20NDND 20NLNL 20NTNT 20PDPD 20PKPK 20PZPZ 20RLRL 20RXRX 20SFSF 20SJSJ 1 2 Insert Model Number 270 271 Insert Case Size 2 3 Taut Band Pivot & Jewel 2 1/2 inches 3 1/2 inches OPTIONS UL & CUL Ratings Custom Scaling Non-standard Ranges Color Bands 58 Yokogawa DC Current & Voltage Meters ORDERING INFORMATION ANALOG METERS Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . DC Ammeters—Zero Left 1 2 00LALA 1 Amp 1 2 00LCLC 1.5 Amp 1 2 00LELE 2 Amp 1 2 00LJLJ 3 Amp 1 2 00LSLS 5 Amp 1 2 00MTMT 10 Amp 1 2 00NDND 15 Amp 1 2 00NGNG* 20 Amp 1 2 00NLNL* 30 Amp 1 2 00NTNT** 50 Amp DC Ammeters—Zero Center 1 2 01LALA 1-0-1 Amp 1 2 01LELE 2-0-2 Amp 1 2 01LSLS 5-0-5 Amp 1 2 01MTMT 10-0-10 Amp 1 2 01NDND* 15-0-15 Amp 1 2 01NGNG* 20-0-20 Amp 1 2 01NLNL* 30-0-30 Amp 1 2 01NTNT** 50-0-50 Amp DC Ammeters—Zero Left, 50mV, Shunt Rated (Lead Resistance Range: .05–.07 Ohm) Scale Only 1 2 24ECNG 20 Amp 1 2 24ECNL 30 Amp 1 2 24ECNT 50 Amp 1 2 24ECPB 75 Amp 1 2 24ECPK 100 Amp 1 2 24ECPZ 150 Amp 1 2 24ECRL 200 Amp 1 2 24ECRS 250 Amp 1 2 24ECRX 300 Amp 1 2 4ECSC 400 Amp 1 2 24ECSF 500 Amp 1 2 24ECSJ 600 Amp 1 2 24ECSN 800 Amp 1 2 24ECVA 1 Kiloamp 1 2 24ECVC 1.5 Kiloamp 1 2 24ECVE 2 Kiloamp * Not available in 11⁄2" ** Not available in 11⁄2" and 21⁄2" 59 ORDERING INFORMATION DC Voltmeters—Zero Left 1 2 20LALA 1.0 Volts 1 2 20LCLC 1.5 Volts 1 2 20LJLJ 3 Volts 1 2 20LSLS 5 Volts 1 2 20MJMJ 8 Volts 1 2 20MTMT 10 Volts 1 2 20NDND 15 Volts 1 2 20NLNL 30 Volts 1 2 20NPNP 40 Volts 1 2 20NTNT 50 Volts 1 2 20PDPD 80 Volts 1 2 20PKPK 100 Volts 1 2 20PZPZ 150 Volts 1 2 20RLRL 200 Volts 1 2 20RSRS 250 Volts 1 2 20RXRX 300 Volts 1 2 20SFSF** 500 Volts 1 2 20SJSJ** 600 Volts DC Voltmeters—Zero Left, Rated 0-1mADC (for use with External Resistor—not included) Scale Only 1 2 04FASF 500 Volts 1 2 04FASJ 600 Volts 1 2 04FASM 750 Volts DC Voltmeters—Zero Center 1 2 21LSLS 5-0-5 Volts 1 2 21MTMT 10-0-10 Volts 1 2 21NLNL 30-0-30 Volts 1 2 21NTNT 50-0-50 Volts 1 2 21PDPD 80-0-80 Volts 1 2 21PZPZ 150-0-150 V 1 2 21RXRX 300-0-300 V 1 2 21SFSF** 500-0-500 V 1 2 21SJSJ** 600-0-600 V ** Not available in 11⁄2" and 21⁄2" Horizon 251/255 L • Accuracy: ±2% of Full Scale • Meets ANSI C-39.1 • Four Display Sizes: 11⁄ 2", 21⁄ 2", 31⁄ 2", and 41⁄ 2" • Severe Duty Meters Optional (21⁄ 2" to 41⁄ 2") to Meet UL1437 SPECIFICATIONS Model 251/255 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.86" x 2.19" x 1.34" 2.66" x 3.12" x 1.81" 3.32" x 3.89" x 1.83" 4.18" x 4.73" x 1.83" Barrel (cutout) 1.53" 2.19" 2.72" 2.72" Window (cutout) 1.05" x 2.18" 1.45" x 3.11" 1.84" x 3.88" 2.22" x 4.72" Model 250/254 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.76" x 1.76" x 1.34" 2.69" x 2.69" x 1.85" 3.50" x 3.50" x 1.85" 4.41" x 4.85" x 1.85" Barrel (cutout) 1.53" 2.17" 2.72" 2.72" Scale Length 1.40" 2.06" 2.88" 3.93" Accuracy 2% Repeatability ±0.5% Response Time 2 sec. (3 sec. on µA) Operating Temperature 0–40°C Storage Temperature –10°C–50°C Dielectric 2600V for 1 min. (0therwise per ANSI except 112⁄ " size 1500V) L Horizon Line and Big Look Series Big Look 250/254 ORDERING CODE GUIDE 1 2 Insert Model Number: 250 251 254 255 Insert Case Size: 1 2 3 4 CASE AND MOVEMENT Big Look - Taut Band Horizon - Taut Band Big Look - Pivot & Jewel Horizon - Pivot & Jewel DISPLAY SIZE 112⁄ " 212⁄ " 312⁄ " 412⁄ " OPTIONS (WHERE APPLICABLE) Custom Scaling Non-standard Ranges 1% Accuracy Adjustable Potentiometer (Voltmeters Only) Zero-Center Color Bands Bezel Insulated Cap Nuts Yokogawa DC Current & Voltage Meters Stylist Series • Accuracy: ±2% of Full Scale • Meets ANSI C-39.1 • Four Display Sizes: 11/2", 21/2", 31/2" and 41/2" • Severe Duty Meters Optional (21/2" to 41/2") to Meet UL1437 • Surface-Mount & Window-Mount Models ORDERING INFORMATION 2% of full scale Voltmeters: 50% momentary, 20% sustained; Ammeters: 10x momenatry, 20% sustained 2 sec. max., except 3 sec. for microammeters 2600V for 1 min. except 11/2" size 1500V ANSI C-39.1 below 500V Stylist 260 with custom color scale DC Ammeter s—Zer o Lef t, 50mV, Shunt Rated (Lead Resistance Range: .05–.07 Ohm) Scale Only: 1 2 20 Amp 24ECNG 1 2 30 Amp 24ECNL 1 2 50 Amp 24ECNT 1 2 75 Amp 24ECPB 1 2 100 Amp 24ECPK 1 2 150 Amp 24ECPZ 1 2 200 Amp 24ECRL 1 2 250 Amp 24ECRS 1 2 300 Amp 24ECRX 1 2 500 Amp 24ECSF 1 2 750 Amp 24ECSM 1 2 1000 Amp 24ECSS 1 2 1500 Amp 24ECTC 1 2 2000 Amp 24ECTM ORDERING CODE GUIDE Insert Model Number: CASE and MOVEMENT 260 Surface Mount - Taut Band 261 Window Mount - Taut Band 264 Surface Mount - Pivot & Jewel 265 Window Mount - Pivot & Jewel 2 Insert Case Size: 1 11/2" 2 21/2" 3 31/2" 4 41/2" Op tions: Color Bands, Mirrored Scale, Non-standard Ranges, Custom Scaling, Severe Duty, Bezel Mounting, Insulated Cap Nuts 1 DC Voltme ter s—Zer o Lef t 1 2 24ECEC 50 millivolts 1 2 24GBGB 100 millivolts 1 2 20LALA 1.0 Volts 1 2 20LCLC 1.5 Volts 1 2 20LJLJ 3 Volts 1 2 20LSLS 5 Volts 1 2 20MJMJ 8 Volts 1 2 20MTMT 10 Volts 1 2 20NDND 15 Volts 1 2 20NLNL 30 Volts 1 2 20NPNP 40 Volts 1 2 20NTNT 50 Volts 1 2 20PDPD 80 Volts 1 2 20PKPK 100 Volts 1 2 20PZPZ 150 Volts 1 2 20RLRL 200 Volts 1 2 20RSRS 250 Volts 1 2 20RXRX 300 Volts 1 2 20SFSF 500 Volts 1 2 20SJSJ 600 Volts 1 2 20SMSM 750 Volts 1 2 20SSSS 1000 Volts DC Voltme ter s—Zer o Lef t, Rat ed 0-1mADC (for use with External Resistor—not included) Scale Only: 1 2 04FASF 500 Volts 1 2 04FASJ 600 Volts 1 2 04FASM 750 Volts DC Voltme ter s—Zer o Cent er 1 2 25ECEC 50-0-50 millivolts 100-0-100 millivolts 1 2 25GBGB 1 2 21LSLS 5-0-5 Volts 1 2 21MTMT 10-0-10 Volts 1 2 21NLNL 30-0-30 Volts 1 2 21NTNT 50-0-50 Volts 1 2 21PDPD 80-0-80 Volts 1 2 21PZPZ 150-0-150 V 1 2 21RXRX 300-0-300 V 1 2 21SFSF 500-0-500 V 1 2 21SJSJ 600-0-600 V 60 ANALOG METERS * Not available in 11/2" Accuracy Overload Response Time Dielectric Standard L Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . DC Amme ter s—Zer o Lef t 1 2 10 microamp 00BZBZ 1 2 20 microamp 00CFCF 1 2 50 microamp 00CYCY 1 2 100 microamp 00DRDR 1 2 200 microamp 00EAEA 1 2 500 microamp 00EMEM 1 2 1 milliamp 00FAFA 1 2 2 milliamp 00FGFG 1 2 5 milliamp 00FXFX 1 2 10 milliamp 00GZGZ 1 2 20 milliamp 00HFHF 1 2 50 milliamp 00HYHY 1 2 100 milliamp 00JRJR 1 2 200 milliamp 00KAKA 1 2 500 milliamp 00KMKM 1 2 1 Amp 00LALA 1 2 1.5 Amp 00LCLC 1 2 2 Amp 00LELE 1 2 3 Amp 00LJLJ 1 2 5 Amp 00LSLS 1 2 10 Amp 00MTMT 1 2 15 Amp 00NDND* 1 2 20 Amp 00NGNG* 1 2 30 Amp 00NLNL* 1 2 50 Amp 00NTNT* DC Amme ter s—Zer o Cent er 1 2 10-0-10 microamp 01BZBZ 1 2 25-0-25 microamp 01CJCJ 1 2 50-0-50 microamp 01CYCY 100-0-100 microamp 1 2 01DRDR 500-0-500 microamp 1 2 01EMEM 1 2 1-0-1 milliamp 01FAFA 1 2 5-0-5 milliamp 01FXFX 1 2 10-0-10 milliamp 01GZGZ 1 2 25-0-25 milliamp 01HJHJ 1 2 50-0-50 milliamp 01HYHY 1 2 100-0-100 milliamp 01JRJR 1 2 200-0-200 milliamp 01KAKA 1 2 500-0-500 milliamp 01KMKM 1 2 1-0-1 Amp 01LALA 1 2 3-0-3 Amp 01LJLJ 1 2 5-0-5 Amp 01LSLS 1 2 10-0-10 Amp 01MTMT 1 2 15-0-15 Amp 01NDND* 1 2 25-0-25 Amp 01NJNJ* 1 2 50-0-50 Amp 01NTNT* SPECIFICATIONS Window Mount Models 261/265 Case Size 21/2" 31/2" 41/2" Size (H x W x D) 2.29" x 3.01" x 2.10" 2.90" x 3.73" x 2.13" 4.60" x 5.18" x 2.13" Zero cutout 0.228" dia. 0.228" dia. 0.228" dia. Window cutout 1.27" x 2.90" 1.595" x 3.61" 2.345" x 5.02" Surface Mount Models 260/264 Case Size 11/2" 21/2" 31/2" 41/2" Size (H x W x D) 1.75" x 1.75" x 1.55" 2.27" x 2.99" x 1.80" 2.87" x 3.70" x 1.80" 3.96" x 5.10" x 1.80" Barrel cutout 1.55" 2.22" 2.82" 2.82" Scale Length 1.66" 2.29" 2.85" 4.01" Simpson Analog Panel Meters DC Voltage/Current SPECIFICATIONS Accuracy: Operating Temp: Overload (1 Sec): Overload (Continuous): L 2123/2124 L 1327/1329 ANALOG METERS Wide Vue Style: Models 1227, 1327 & 1329 • UL Recognized • Wide Angle Visibility • Plastic Case with Clear Acrylic Window • Additional Ranges Upon Request Century Style: Models 2122, 2123 & 2124 • UL Recognized • Phenolic Case and Glass Window • Additional Ranges Upon Request DC Ammeters Model 1227 21⁄2" Range Scale Catalog # 0-1 0-1 02440 0-1.5 0-1.5 02450 0-2 0-2 02460 0-3 0-3 02470 0-5 0-5 02480 0-10 0-10 02490 0-15 0-15 02500 0-25 0-25 02510 0-30 0-30 02520 0-50 0-50 02530 0-50 mV 0-100 02540* 0-50 mV 0-150 02550* 0-50 mV 0-200 02552* 0-50 mV 0-300 02554* 0-50 mV 0-500 — 15-0-15 15-0-15 — 30-0-30 30-0-30 — 50-0-50 50-0-50 — Model 1327 31⁄2" Catalog # 02640 02650 02660 02670 02680 02690 02700 02710 02720 02730 02740* 02750* 02760* 02770* 02780* 02790 02800 02810 Model 1329 41⁄2" Catalog # 02820 02830 02840 02850 02860 02870 02880 02890 02900 02910 02920* 02930* 02940* 02950* 02960* — — — DC Ammeters Model 2122 21⁄2" Range Scale Catalog # 0-1 0-1 17400 0-1.5 0-1.5 17401 0-2 0-2 17402 0-3 0-3 17403 0-5 0-5 17404 0-10 0-10 17405 0-15 0-15 17406 0-25 0-25 17407 0-30 0-30 17408 0-50 0-50 17409 0-50 mV 0-100 17410* 0-50 mV 0-150 — 0-50 mV 0-200 17412* 0-50 mV 0-300 — 0-50 mV 0-500 — 15-0-15 15-0-15 — 30-0-30 30-0-30 — Model 2123 31⁄2" Catalog # 17475 17476 17477 17478 17479 17480 17481 17482 17483 17484 17485* 17486* 17487* 17488* 17489* 17490 17491 Model 2124 41⁄2" Catalog # 17565 — 17567 17568 17569 17570 17571 17572 17573 17574 17575* 17576* 17577* 17578* 17579* — — * DC Current meters are self-contained through 50 amps. Higher ranges are supplied as 50mV meters and require an external shunt. Both WideVue and Century styles are available in 1 1/2" Sizes. Call for info. 61 Dimensions 1227 1327 1329 2122 2123 2124 ± 2% of Full Scale -20 to 65°C 10 Times Full Scale Rating 1.5 Times Full Scale Rating Height 2.47" 3.25" 4.68" 2.34" 3.00" 4.20" Width 2.47" 3.25" 4.68" 2.38" 3.00" 4.66" Housing 2.17" Dia. 2.73" Dia. 2.75" Dia. 2.16" Dia. 2.69" Dia. 2.69" Dia. DC Millivoltmeters Model 1227 21⁄2" Range Scale Catalog # 0-50 0-50 07010 50-0-50 50-0-50 — Model 1327 31⁄2" Catalog # 07020 07021 Model 1329 41⁄2" Catalog # 07030 07031 DC Millivoltmeters Model 2122 21⁄2" Range Scale Catalog # 0-50 0-50 17472 50-0-50 50-0-50 — Model 2123 31⁄2" Catalog # 17540 17541 Model 2124 41⁄2" Catalog # 17636 17635 DC Voltmeters Range Scale 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-100 0-100 0-150 0-150 0-200 0-200 0-250 0-250 0-300 0-300 0-500 0-500 0-750 0-750 Model 1227 21⁄2" Catalog # 09550 09560 09570 09580 09590 09600 09610 09620 09622 09623 09630 09640 09650** Model 1327 31⁄2" Catalog # 09720 09740 09750 09760 09770 09780 09790 09800 09810 09820 09830 09840 09850 Model 1329 41⁄2" Catalog # 09870 09890 09900 09910 09920 09930 09940 09950 09960 09970 09980 09990 10000 DC Voltmeters Range Scale 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-100 0-100 0-150 0-150 0-200 0-200 0-250 0-250 0-300 0-300 0-500 0-500 0-750 0-750 Model 2122 21⁄2" Catalog # 17445 17446 17447 17448 17449 17450 17451 17452 — — 17455 17456 — Model 2123 31⁄2" Catalog # 17525 17527 17528 17529 17530 17531 17532 17533 17534 17535 17536 17537 17538 Model 2124 41⁄2" Catalog # 17618 17620 17621 17622 17623 17624 17625 17626 17627 17628 17629 17630 17631 DC Milliammeters Range Scale 0-1 0-1 0-3 0-3 0-5 0-5 0-10 0-10 0-25 0-25 0-50 0-50 Model 1227 21⁄2" Catalog # 06175 06180 06190 06200 06220 06230 Model 1327 31⁄2" Catalog # 06310 06320 06330 06340 06370 06380 Model 1329 41⁄2" Catalog # 06470 06480 06490 06495 06530 06540 DC Milliammeters Range Scale 0-1 0-1 0-3 0-3 0-5 0-5 0-10 0-10 0-25 0-25 0-50 0-50 Model 2122 21⁄2" Catalog # 17430 17431 17432 17433 17436 17437 Model 2123 31⁄2" Catalog # 17510 17511 17512 17513 17516 17517 Model 2124 41⁄2" Catalog # 17600 17601 17602 17603 17606 17607 **External Multiplier furnished Jewell DC Current & Voltage Meters Modutec S & W Series • Five Display Sizes: 11/2", 21/2", 31/2", 41/2" and 51/2" • Shielded Taut-Band Movement • Surface-Mount or Window-Mount Models L S Series SPECIFICATIONS Model W Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.77 x 2.26 x 1.83" 2.29 x 3.01 x 2.10" 2.90 x 3.73 x 2.12" 4.06 x 5.18 x 2.17" 4.60 x 5.97 x 2.17" Window (cutout) 0.935 x 2.15" 1.27 x 2.90" 1.595 x 3.61" 2.345 x 5.02" 2.59 x 5.78" Model S Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.75 x 2.24 x 1.55" 2.27 x 2.99 x 1.80" 2.87 x 3.70 x 1.80" 3.96 x 5.10 x 1.80" 4.48 x 5.85 x 1.80" Barrel (cutout) 1.55" 2.22" 2.82" 2.82" 2.82" All Models: Scale Length 1.75" 2.41" 3.0" 4.22" 5.12" Accuracy ±2% of full scale Repeatability ±0.5% of full scale Response Time 1.5 sec. (except 3 sec. for <50µA full scale) ORDERING CODE GUIDE ORDERING INFORMATION W Series ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 and Model Code in box 2 . DC Millivoltme ter s – Zer o lef t, 200Ω/V 1 2 -DMV-050 0-50 1 2 -DMV-100 0-100 DC Millivoltme ter s – Zer o cent er, 200Ω/V 1 2 -DMV-50U50 50-0-50 1 2 -DMV-1H1 100-0-100 DC Voltme ter s – Zer o lef t, 1000Ω/V, except *10kΩ/V 1 2 -DVV-001 0-1 1 2 -DVV-0015 0-1.5 1 2 -DVV-002 0-2 1 2 -DVV-003 0-3 1 2 -DVV-005 0-5 1 2 -DVV-010 0-10 1 2 -DVV-015 0-15 1 2 -DVV-020 0-20 1 2 -DVV-025 0-25 1 2 -DVV-030 0-30 1 2 -DVV-040 0-40 1 2 -DVV-050 0-50 1 2 -DVV-075 0-75 1 2 -DVV-080 0-80 1 2 -DVV-100 0-100 1 2 -DVV-150 0-150 1 2 -DVV-200 0-200 1 2 -DVV-250 0-250 1 2 -DVV-300 0-300 1 2 -DVV-500 0-500 1 2 -DVV-600 * 0-600 1 2 -DVV-750 * 0-750 1 2 -DVV-1000 * 0-1000 DC Voltme ter s – Zer o cent er, 1000Ω/V, except *10kΩ/V 1 2 -DVV-5U5 5-0-5 1 2 -DVV-10U10 10-0-10 1 2 -DVV-15U15 15-0-15 1 2 -DVV-25U25 25-0-25 1 2 -DVV-50U50 50-0-50 1 2 -DVV-1H1 100-0-100 1 2 -DVV-1.5H1.5 150-0-150 1 2 -DVV-3H3 300-0-300 1 2 -DVV-5H5 500-0-500 1 2 -DVV-6H6 * 600-0-600 1 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 -DUA-050 -DUA-100 -DUA-200 -DUA-500 -DUA-25U25 -DUA-50U50 -DUA-1H1 -DUA-5H5 -DMA-001 -DMA-002 -DMA-003 -DMA-005 -DMA-010 -DMA-015 -DMA-020 -DMA-025 -DMA-030 -DMA-050 -DMA-100 -DMA-150 -DMA-200 -DMA-300 -DMA-500 -DMA-750 -DMA-1U1 -DMA-5U5 -DMA-10U10 -DMA-25U25 -DMA-50U50 -DMA-1H1 -DMA-2H2 -DMA-5H5 -DAA-001 -DAA-001.5 -DAA-002 -DAA-003 -DAA-005 -DAA-010 -DAA-015 ** -DAA-020 ** -DAA-025 ** -DAA-030 ** -DAA-050 ** -DAA-1U1 -DAA-3U3 -DAA-5U5 -DAA-10U10 -DAA-15U15 ** -DAA-25U25 ** -DAA-50U50 ** 2 Insert Size Code: 1 2 3 4 5 Insert Model Code: S W CASE SIZE 11/2" 21/2" 31/2" 41/2" 51/2" STYLE Surface Mount Window Mount ANALOG METERS L DC Micr oamme ter s - Zer o lef t 0-50 2600 0-100 640 0-200 220 0-500 135 DC Micr oamme ter s - Zer o cent er 25-0-25 2600 50-0-50 640 100-0-100 230 500-0-500 35 DC Milliamme ter s – Zer o lef t 0-1 35.0 0-2 12.5 0-3 7.2 0-5 3.8 0-10 2.2 0-15 3.3 0-20 2.5 0-25 2.0 0-30 1.7 0-50 1.0 0-100 .50 0-150 .33 0-200 .25 0-300 .166 0-500 .10 0-750 .066 DC Milliamme ter s - Zer o cent er 1-0-1 35.0 5-0-5 3.5 10-0-10 2.2 25-0-25 2.0 50-0-50 1.0 100-0-100 .50 200-0-200 .25 500-0-500 .10 DC Amme ter s - Zer o lef t, self-cont ained 0-1 .050 0-1.5 .033 0-2 .025 0-3 .0166 0-5 .010 0-10 .0050 0-15 .0033 0-20 .0025 0-25 .0020 0-30 .0015 0-50 .0010 DC Amme ter s - Zer o cent er, self cont ained 1-0-1 .050 3-0-3 .016 5-0-5 .010 10-0-10 .005 15-0-15 .003 25-0-25 .002 50-0-50 .001 OPTIONS Custom Scaling Mirror Scale High Torque Movement Suppressed Zero Color Bands Illumination Sealed Case Bezel Mount Kit ORDERING INFORMATION DC Amme ter s - Zer o lef t, 50mV, shunt r at ed 1 2 -DAA-075 0-75 1 2 -DAA-100 0-100 1 2 -DAA-150 0-150 1 2 -DAA-200 0-200 1 2 -DAA-300 0-300 1 2 -DAA-500 0-500 1 2 -DAA-750 0-750 1 2 -DAA-1000 0-1000 1 2 -DAA-1200 0-1200 1 2 -DAA-1500 0-1500 1 2 -DAA-2000 0-2000 DC Amme ter s - Zer o lef t, 100mv, shunt r at ed 0-75 E 1 2 -DAA-075 0-100 E 1 2 -DAA-100 0-150 E 1 2 -DAA-150 0-200 E 1 2 -DAA-200 0-300 E 1 2 -DAA-300 0-500 E 1 2 -DAA-500 0-750 E 1 2 -DAA-750 0-1000 E 1 2 -DAA-1000 0-1200 E 1 2 -DAA-1200 0-1500 E 1 2 -DAA-1500 0-2000 E 1 2 -DAA-2000 DC Amme ter s - Zer o cent er, 50mV, shunt r at ed 1 2 -DAA-75U75 75-0-75 1 2 -DAA-1H1 100-0-100 1 2 -DAA-2H2 200-0-200 1 2 -DAA-3H3 300-0-300 1 2 -DAA-4H4 400-0-400 1 2 -DAA-5H5 500-0-500 ** not available in 11/2" size 62 Jewell DC Current & Voltage Meters Modutec PB Series • Four Display Sizes: 1½", 2½", 3½", and 4½" • Shielded Taut-Band Movement • Large, Easy to Read Scale SPECIFICATIONS Model Case Size Size (H x W x D) Barrel (cutout) Scale Length Accuracy Repeatability Response Time 1½" 1.75 x 1.75 x 1.39" 1.53" 1.26" PB Series 2½" 3½" 2.70 x 2.70 x 1.77" 3.50 x 3.50 x 1.77" 2.20" 2.75" 2.10" 2.90" 4½" 4.41 x 4.85 x 1.84" 2.79" 4.00" ±2% of full scale ±0.5% of full scale 1.5 sec. (except 3 sec. for <50μA full scale) The PB series industrial panel board meters meet or exceed the requirements of ANSI C39.1. The mounting stud configuration complies with ANSI standards. Number of studs varies by size: 1½" meters - 2 studs; 2½" & 3½" meters - 3 studs; 4½" meters - 4 studs. ORDERING CODE GUIDE ORDERING INFORMATION PB Series ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 . DC Millivoltmeters – Zero left, 200Ω/V 1 PB-DMV-050 0-50 1 PB-DMV-100 0-100 DC Millivoltmeters – Zero center, 200Ω/V 1 PB-DMV-50U50 50-0-50 1 PB-DMV-1H1 100-0-100 DC Voltmeters – Zero left, 1000Ω/V, except *10kΩ/V 1 PB-DVV-001 0-1 1 PB-DVV-0015 0-1.5 1 PB-DVV-002 0-2 1 PB-DVV-003 0-3 1 PB-DVV-005 0-5 1 PB-DVV-010 0-10 1 PB-DVV-015 0-15 1 PB-DVV-020 0-20 1 PB-DVV-025 0-25 1 PB-DVV-030 0-30 1 PB-DVV-040 0-40 1 PB-DVV-050 0-50 1 PB-DVV-075 0-75 1 PB-DVV-080 0-80 1 PB-DVV-100 0-100 1 PB-DVV-150 0-150 1 PB-DVV-200 0-200 1 PB-DVV-250 0-250 1 PB-DVV-300 0-300 1 PB-DVV-500 0-500 1 PB-DVV-600 * 0-600 1 PB-DVV-750 * 0-750 1 PB-DVV-1000 * 0-1000 DC Voltmeters – Zero center, 1000 Ω/V, except *10k Ω/V 1 PB-DVV-5U5 5-0-5 1 PB-DVV-10U10 10-0-10 1 PB-DVV-15U15 15-0-15 1 PB-DVV-25U25 25-0-25 1 PB-DVV-50U50 50-0-50 1 PB-DVV-1H1 100-0-100 1 PB-DVV-1.5H1.5 150-0-150 1 PB-DVV-3H3 300-0-300 1 PB-DVV-5H5 500-0-500 1 PB-DVV-6H6 * 600-0-600 DC Microammeters - Zero left 0-50 4000 Ω 0-100 900 0-200 306 0-500 203 DC Microammeters - Zero center 25-0-25 4000 50-0-50 900 100-0-100 305 500-0-500 41 DC Milliammeters – Zero left 0-1 43.0 0-2 16.7 0-3 8.3 0-5 3.8 0-10 2.2 0-15 3.3 0-20 2.5 0-25 2.0 0-30 1.7 0-50 1.0 0-100 .50 0-150 .33 0-200 .25 0-300 .166 0-500 .10 0-750 .066 DC Milliammeters - Zero center 1-0-1 35.0 5-0-5 3.4 10-0-10 1.8 25-0-25 2.0 50-0-50 1.0 100-0-100 .50 200-0-200 .25 500-0-500 .10 DC Ammeters - Zero left, self-contained 0-1 .050 0-1.5 .033 0-2 .025 0-3 .0166 0-5 .010 0-10 .0050 0-15 .0033 0-20 .0025 0-25 .0020 0-30 .0015 0-50 .0010 DC Ammeters - Zero center, self contained 1-0-1 .050 3-0-3 .016 5-0-5 .010 10-0-10 .005 15-0-15 .003 25-0-25 .002 50-0-50 .001 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PB-DUA-050 PB-DUA-100 PB-DUA-200 PB-DUA-500 PB-DUA-25U25 PB-DUA-50U50 PB-DUA-1H1 PB-DUA-5H5 PB-DMA-001 PB-DMA-002 PB-DMA-003 PB-DMA-005 PB-DMA-010 PB-DMA-015 PB-DMA-020 PB-DMA-025 PB-DMA-030 PB-DMA-050 PB-DMA-100 PB-DMA-150 PB-DMA-200 PB-DMA-300 PB-DMA-500 PB-DMA-750 PB-DMA-1U1 PB-DMA-5U5 PB-DMA-10U10 PB-DMA-25U25 PB-DMA-50U50 PB-DMA-1H1 PB-DMA-2H2 PB-DMA-5H5 PB-DAA-001 PB-DAA-0015 PB-DAA-002 PB-DAA-003 PB-DAA-005 PB-DAA-010 PB-DAA-015 ** PB-DAA-020 ** PB-DAA-025 ** PB-DAA-030 ** PB-DAA-050 ** PB-DAA-1U1 PB-DAA-3U3 PB-DAA-5U5 PB-DAA-10U10 PB-DAA-15U15 ** PB-DAA-25U25 ** PB-DAA-50U50 ** Insert Size Code: 1 2 3 4 CASE SIZE 1½" 2½" 3½" 4½" OPTIONS Custom Scaling Mirror Scale High Torque Movement Suppressed Zero Color Bands Heavy Damping ORDERING INFORMATION DC Ammeters - Zero left, 50mV, shunt rated 1 PBS-DAA-075 0-75 1 PBS-DAA-100 0-100 1 PBS-DAA-150 0-150 1 PBS-DAA-200 0-200 1 PBS-DAA-300 0-300 1 PBS-DAA-500 0-500 1 PBS-DAA-750 0-750 1 PBS-DAA-1000 0-1000 1 PBS-DAA-1200 0-1200 1 PBS-DAA-1500 0-1500 1 PBS-DAA-2000 0-2000 DC Ammeters - Zero left, 100mv, shunt rated 0-75 E 1 PB-DAA-075 0-100 E 1 PB-DAA-100 0-150 E 1 PB-DAA-150 0-200 E 1 PB-DAA-200 0-300 E 1 PB-DAA-300 0-500 E 1 PB-DAA-500 0-750 E 1 PB-DAA-750 0-1000 E 1 PB-DAA-1000 0-1200 E 1 PB-DAA-1200 0-1500 E 1 PB-DAA-1500 0-2000 E 1 PB-DAA-2000 DC Ammeters - Zero center, 50mV, shunt rated 1 PBS-DAA-75U75 75-0-75 1 PBS-DAA-1H1 100-0-100 1 PBS-DAA-2H2 200-0-200 1 PBS-DAA-3H3 300-0-300 1 PBS-DAA-4H4 400-0-400 1 PBS-DAA-5H5 500-0-500 ** not available in 1½" size 62a Yokogawa AC Current and Voltage Meters ORDERING INFORMATION ANALOG METERS Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . AC Microammeters and Milliammeters, Rectifier Type, Accuracy ±3% (60 Hz Sinewave @ 25°C) 1 2 10EMEM 500 µA 1 2 10EWEW 800 µA 1 2 10FAFA 1 mA 1 2 10FDFD 1.5 mA 1 2 10FGFG 2 mA 1 2 10F NF N 3 mA 1 2 10F XF X 5 mA 1 2 10GZGZ 10 mA 1 2 10HFHF 20 mA AC Milliameters-Self Contained, 25-400 Hz, Iron Vane, Pivot and Jewel 1 2 40GZGZ* 10 mA 1 2 40HJHJ* 25 mA 1 2 40HYHY* 50 mA 1 2 40JRJR* 100 mA 1 2 40K AK A* 200 mA 1 2 40K MK M* 500 mA AC Ammeters-Self Contained, 25-400 Hz, Iron Vane, Pivot and Jewel 1 2 40LALA* 1 Amp 1 2 40L JL J* 3 Amp 1 2 40LSLS* 5 Amp 1 2 40MJMJ* 8 Amp 1 2 40MTMT* 10 Amp 1 2 40NDND* 15 Amp 1 2 40NGNG* 20 Amp 1 2 40NLNL* 30 Amp 1 2 40NTNT** 50 Amp 1 2 40PDPD** 80 Amp AC Ammeters-Transformer Rated, 0-5 Amperes, 25-400 Hz, Iron Vane, Pivot and Jewel (Scale Only) 1 2 40LSMT* 10 Amp 1 2 40LSND* 15 Amp 1 2 40LSNG* 20 Amp 1 2 40LSNL* 30 Amp 1 2 40LSNP* 40 Amp 1 2 40LSNT* 50 Amp 1 2 40LSPB* 75 Amp 1 2 40LSPD* 80 Amp 1 2 40LSPK* 100 Amp 1 2 40LSPZ* 150 Amp 1 2 40LSRL* 200 Amp 1 2 40LSRX* 300 Amp 1 2 40LSSC* 400 Amp 1 2 40LSSF* 500 Amp 1 2 40LSSJ* 600 Amp 1 2 40LSSN* 800 Amp 1 2 40LSVA* 1.0 kA 1 2 40LSVB* 1.2 kA 1 2 40LSVC* 1.5 kA 1 2 40LSVE* 2.0 kA 1 2 40LSVJ* 3.0 kA 63 AC Voltmeter-Self Contained, Rectifier Type, Accuracy ±3% (60 Hz Sinewave @ 25°C) 1 2 30MTMT 10 Volts 1 2 30NDND 15 Volts 1 2 30NGNG 20 Volts 1 2 30NJNJ 25 Volts 1 2 30NLNL 30 Volts 1 2 30NTNT 50 Volts 1 2 30PDPD 80 Volts 1 2 30PKPK 100 Volts 1 2 30PZPZ 150 Volts 1 2 30RLRL** 200 Volts 1 2 30RSRS** 250 Volts 1 2 30RXRX** 300 Volts AC Voltmeter-Expanded Scale, Rectifier Type, Accuracy ±0.5% of full scale 1 2 37PNPN** 110-130 Volts 1 2 37PTPT** 105-125 Volts AC Voltmeter-Self Contained, Iron Vane, Pivot and Jewel 60 Hz Available in 250 and 251 only 1 2 44LJLJ* 3 Volts 1 2 44LSLS* 5 Volts 1 2 44MTMT* 10 Volts 1 2 44NDND* 15 Volts 1 2 44NLNL* 30 Volts 1 2 44NTNT* 50 Volts 1 2 44PKPK* 100 Volts 1 2 44PZPZ* 150 Volts 1 2 44RXRX* 300 Volts 1 2 44SFSF** 500 Volts 1 2 44SJSJ** 600 Volts AC Voltmeter-Self Contained, Iron Vane, Pivot and Jewel 400 Hz Available in 250 and 251 only 1 2 45PZPZ* 150 Volts 1 2 45RXRX* 300 Volts AC Voltmeter-Transformer Rated, 0-150 Volts Iron Vane, Pivot and Jewel, 60 Hz Available in 250 and 251 only Scale 1 2 44PZSJ* 600 Volts 1 2 44PZSM* 750 Volts 1 2 44PZVJ* 3 kV * Not Available in 11⁄2" ** Not available in 11⁄2" and 21⁄2" *** Custom scale can be matched to any transformer primary voltage L • Accuracy: ±2% Iron Vane Type; ±3% Rectifier Type • Four Display Sizes: 11⁄ 2", 21⁄ 2", 31⁄ 2", and 41⁄ 2" • Severe Duty Meters Optional (21⁄ 2" to 41⁄ 2") to Meet UL1437 SPECIFICATIONS Model 251/255 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.86" x 2.19" x 1.34" 2.66" x 3.12" x 1.81" 3.32" x 3.89" x 1.83" 4.18" x 4.73" x 1.83" Barrel (cutout) 1.53" 2.19" 2.72" 2.72" Window (cutout) 1.45" x 2.18" 1.45" x 3.11" 1.84" x 3.88" 2.22" x 4.72" Model 250/254 Case Size 11⁄2" 21⁄2" 31⁄2" 41⁄2" Size (H x W x D) 1.76" x 1.76" x 1.34" 2.69" x 2.69" x 1.85" 3.50" x 3.50" x 1.85" 4.41" x 4.85" x 1.85" Barrel (cutout) 1.53" 2.17" 2.72" 2.72" Scale Length 1.40" 2.06" 2.88" 3.93" All Models: Accuracy 2% iron vane type, 3% AC rectifier type (60 Hz sinewave) Repeatability ±0.5% Response Time 2.5 sec. Operating Temperature 0–40°C Big Look 250/254 Series L Horizon Line and Big Look Series Horizon Line 251/255 ORDERING CODE GUIDE 1 2 Insert Model Number: CASE AND MOVEMENT 250 Big Look - Taut Band 251 Horizon - Taut Band 254 Big Look - Pivot & Jewel 255 Horizon - Pivot & Jewel Insert Case Size: DISPLAY SIZE 1 112⁄ " 2 212⁄ " 3 312⁄ " 4 412⁄ " OPTIONS (WHERE APPLICABLE) Custom Scaling Non-standard Ranges 1% Accuracy Adjustable Potentiometer (Voltmeters Only) Zero-Center Color Bands Bezel Insulated Cap Nuts Yokogawa AC Current and Voltage Meters Stylist Series • Accuracy: ±2% Iron Vane Type; ±3% Rectifier Type • Four Display Sizes: 11/2", 21/2", 31/2" and 41/2" • Severe Duty Meters Optional (21/2" to 41/2") to Meet UL1437 ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Model Code in box 1 and Case Size in box 2 . Accuracy Overload Response Time Dielectric 2% iron vane type, 3% AC rectifier type (60 Hz sinewave) Voltmeters: 50% momentary, 20% sustained; Ammeters: 10x momenatry, 20% sustained 2.5 sec. max. 2600V for 1 min. except 11/2" size 1500V Stylist 260 with optional white on black scale AC Amme ter s-Transf or mer Rat ed, 0-5 Amper es, 50-400 Hz, Ir on Vane*** Scale Only: 1 2 10 Amp 40LSMT* 1 2 15 Amp 40LSND* 1 2 20 Amp 40LSNG* 1 2 30 Amp 40LSNL* 1 2 40 Amp 40LSNP* 1 2 50 Amp 40LSNT* 1 2 75 Amp 40LSPB* 1 2 80 Amp 40LSPD* 1 2 100 Amp 40LSPK* 1 2 150 Amp 40LSPZ* 1 2 200 Amp 40LSRL* 1 2 300 Amp 40LSRX* 1 2 400 Amp 40LSSC* 1 2 500 Amp 40LSSF* 1 2 600 Amp 40LSSJ* 1 2 800 Amp 40LSSN* 1 2 1.0 kA 40LSVA* 1 2 1.2 kA 40LSVB* 1 2 1.5 kA 40LSVC* 1 2 2.0 kA 40LSVE* 1 2 3.0 kA 40LSVJ* ORDERING CODE GUIDE 1 2 Insert Model Number: CASE and MOVEMENT 260 Surface Mount - Taut Band or Iron Vane 261 Window Mount - Taut Band or Iron Vane 264 Surface Mount - Pivot & Jewel 265 Window Mount - Pivot & Jewel Insert Case Size: 1 11/2" 2 21/2" 3 31/2" 4 41/2" Op tions: Custom Scaling, Non-standard Ranges, Severe Duty, Color Bands, Bezel Mounting, Insulated Cap Nuts AC Voltme ter-Self Cont ained, Rectif ier Type 1 2 30L JL J** 3 Volts 1 2 30LSLS** 5 Volts 1 2 30MTMT** 10 Volts 1 2 30NDND** 15 Volts 1 2 30NJNJ** 25 Volts 1 2 30NTNT** 50 Volts 1 2 30PKPK** 100 Volts 1 2 30PZPZ** 150 Volts 1 2 30RXRX** 300 Volts 1 2 30SFSF** 500 Volts 1 2 30SJSJ** 600 Volts AC Voltme ter-Expanded Scale, Rectif ier Type Accuracy ±0.5% FS 1 2 37PTPT* 105-125 Volts 1 2 37RRRR 210-250 Volts AC Voltme ter-Self Cont ained, 60 Hz Ir on Vane*** 1 2 44LSLS* 5 Volts 1 2 44MTMT* 10 Volts 1 2 44NDND* 15 Volts 1 2 44NLNL* 30 Volts 1 2 44NTNT* 50 Volts 1 2 44PKPK* 100 Volts 1 2 44PZPZ* 150 Volts 1 2 44RXRX* 300 Volts 1 2 44SFSF* 500 Volts 1 2 44SJSJ * 600 Volts AC Voltme ter-Transf or mer Rat ed, 0-150 Volts Scale Only 1 2 30PZSM** 750 Volts 1 2 30PZTC** 1500 Volts 1 2 30PZUA** 3000 Volts AC Voltme ter-Transf or mer Rat ed, 0-150 Volts Ir on Vane*** Scale Only: 1 2 44PZSJ* 600 Volts 1 2 44PZSM* 750 Volts 1 2 44PZVJ* 3 kV * Not Available in 11/2" ** 11/2" in surface mount only ***Use 260 for Surface Mount, 261 for Window Mount 64 ANALOG METERS L AC Milliamme ter s, Rectif ier Type , 60 Hz 1 2 10FAFA 1 mA 1 2 10FXFX 5 mA 1 2 10GZGZ 10 mA 1 2 10HJHJ 25 mA 1 2 10HYHY 50 mA 1 2 10JRJR 100 mA 1 2 10KAKA* 200 mA AC Milliame ter s-Self Cont ained, 50-400 Hz Ir on Vane*** 1 2 40GZGZ* 10 mA 1 2 40HJHJ* 25 mA 1 2 40HYHY* 50 mA 1 2 40JRJR* 100 mA 1 2 40KDKD* 250 mA 1 2 40KMKM* 500 mA AC Amme ter s-Self Cont ained, 50-400 Hz Ir on Vane*** 1 2 40LALA* 1 Amp 1 2 40LELE* 2 Amp 1 2 40L JL J* 3 Amp 1 2 40LSLS* 5 Amp 1 2 40MTMT* 10 Amp 1 2 40NDND* 15 Amp 1 2 40NGNG* 20 Amp 1 2 40NLNL* 30 Amp 1 2 40NTNT* 50 Amp AC Amme ter s-Self Cont ained, Rectif ier Type, 60 Hz 1 2 10LALA* 1 Amp 1 2 10LELE* 2 Amp 1 2 10L JL J* 3 Amp 1 2 10LSLS* 5 Amp 1 2 10MTMT* 10 Amp 1 2 10NDND* 15 Amp 1 2 10NGNG* 20 Amp 1 2 10NJNJ* 25 Amp 1 2 10NLNL* 30 Amp AC Amme ter s-Transf or mer Rat ed, 0-5 Amper es, Rectif ier Type, 60 Hz Scale Only: 1 2 10LSNT* 50 Amp 1 2 10LSPB* 75 Amp 1 2 10LSPK* 100 Amp 1 2 10LSPZ* 150 Amp 1 2 10LSRL* 200 Amp 1 2 10LSRX* 300 Amp 1 2 10LSSF* 500 Amp 1 2 10LSSJ* 600 Amp 1 2 10LSSN* 800 Amp 1 2 10LSSS* 1000 Amp 1 2 10LSTC* 1500 Amp 1 2 10LSTM* 2000 Amp SPECIFICATIONS Window Mount Models 261/265 Case Size 21/2" 31/2" 41/2" Size (H x W x D) 2.29" x 3.01" x 2.10" 2.90" x 3.73" x 2.13" 4.60" x 5.18" x 2.13" Zero cutout 0.228" dia. 0.228" dia. 0.228" dia. Window cutout 1.27" x 2.90" 1.595" x 3.61" 2.345" x 5.02" Surface Mount Models 260/264 Case Size 11/2" 21/2" 31/2" 41/2" Size (H x W x D) 1.75" x 1.75" x 1.55" 2.27" x 2.99" x 1.80" 2.87" x 3.70" x 1.80" 3.96" x 5.10" x 1.80" Barrel cutout 1.55" 2.22" 2.82" 2.82" Simpson Analog Panel Meters AC Voltage/Current L SPECIFICATIONS Century Style L Accuracy: Operating Temp: Overload (1 Sec): Overload (Continuous): ANALOG METERS Wide Vue Wide Vue Style: Models 1247, 1257, 1347, 1357, 1349 & 1359 Century Style: Models 2142, 2143, 2152, 2153, 2144 & 2154 • UL Recognized • Wide Angle Visibility • Phenolic Case with Acrylic Window • Additional Ranges Upon Request • UL Recognized • Phenolic Case and Glass Window • Additional Ranges Upon Request AC Ammeters (Self-Contained) Range Scale 0-1 0-1 0-2 0-2 0-3 0-3 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-75 0-75 Model 1257 21⁄2" Model 1357 31⁄2" Model 1359 41⁄2" Catalog # 02560 — 02575 02580 02590 02599 02609 02615 02619 — Catalog # 03130 03150 03160 03170 03180 03190 03200 03205 03210 03215 Catalog # 03260 03280 03290 03300 03310 03320 03330 03335 03340 03345 AC Ammeters (Self-Contained) Range Scale 0-1 0-1 0-2 0-2 0-3 0-3 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-30 0-30 0-50 0-50 0-75 0-75 Model 2152 21⁄2" Model 2153 31⁄2" Model 2154 41⁄2" Catalog # 17665 — 17667 17668 17669 17670 17671 17672 17673 — Catalog # 17695 17697 17698 17699 17700 17701 17702 17703 17704 17710 Catalog # 17740 17742 17743 17744 17745 17746 17747 17748 17749 17755 AC Ammeters** (for use with CT) Range Scale 0-5 0-25 0-5 0-50 0-5 0-75 0-5 0-100 0-5 0-150 0-5 0-200 0-5 0-300 Model 1257 21⁄2" Model 1357 31⁄2" Model 1359 41⁄2" Catalog # — — — 02622 02624 02626 02627 Catalog # 35074 35075 35076 03220 03230 03240 03250 Catalog # 35078 35079 35080 03350 03360 03370 03380 AC Ammeters** (for use with CT) Range Scale 0-5 0-25 0-5 0-50 0-5 0-75 0-5 0-100 0-5 0-150 0-5 0-200 0-5 0-300 Model 2152 21⁄2" Model 2153 31⁄2" Model 2154 41⁄2" Catalog # — — — 176744 — — — Catalog # 35082 35083 35084 17706 17707 17708 17709 Catalog # 35086 35087 35088 17751 17752 17753 17754 Dimensions 1247, 1257 1347, 1357 1349, 1359 2142, 2152 2143, 2153 2144, 2154 ±2% of Full Scale (±3% Rectifier Type) -20 to 65°C 10 Times Full Scale Rating 1.5 Times Full Scale Rating Height 2.47" 3.25" 4.68" 2.34" 3.00" 4.20" Width 2.47" 3.25" 4.68" 2.38" 3.00" 4.66" Housing 2.17" Dia. 2.73" Dia. 2.75" Dia. 2.16" Dia. 2.69" Dia. 2.69" Dia. AC Voltmeters-Rectified Model 1247 21⁄2" Range Scale Catalog # 0-5 0-5 10015 0-10 0-10 10016 0-15 0-15 — 0-50 0-50 — 0-150 0-150 10017 0-300 0-300 10018 Model 1347 31⁄2" Catalog # 10020 10030 10040 10050 10060 10070 Model 1349 41⁄2" Catalog # 10090 10100 10110 10120 10130 10140 AC Voltmeters-Rectified Model 2142 21⁄2" Range Scale Catalog # 0-5 0-5 17460 0-10 0-10 — 0-15 0-15 — 0-50 0-50 — 0-150 0-150 17462 Model 2143 31⁄2"Catalog # 17542 17543 17544 17545 17546 Model 2144 41⁄2" Catalog # 17640 17641 17642 17643 17644 Voltmeters-Iron Vane Range Scale 0-5 0-5 0-10 0-10 0-15 0-15 0-25 0-25 0-50 0-50 0-100 0-100 0-150 0-150 0-250 0-250 0-300 0-300 0-500 0-500 Model 1257 21⁄2" Catalog # — 09670 09675 09680 09690 09695 09700 09705 09710 09715* Model 1357 31⁄2" Catalog # 10160 10170 10180 10190 10200 10210 10220 10230 10240 10250* Model 1359 41⁄2" Catalog # 10260 10270 10280 10290 10300 10310 10320 10330 10340 10350* Voltmeters-Iron Vane Range Scale 0-10 0-10 0-15 0-15 0-25 0-25 0-50 0-50 0-100 0-100 0-150 0-150 0-250 0-250 0-300 0-300 0-500 0-500 Model 2152 21⁄2" Catalog # 17685 17686 17687 17688 — 17690 17691 17692 — Model 2153 31⁄2" Catalog # 17726 17727 17728 17729 17730 17731 17732 17733 17734* Model 2154 41⁄2" Catalog # 17771 17772 17773 17774 17775 17776 17777 17778 17779* AC Milliammeters Range Scale 0-10 0-10 0-50 0-50 0-100 0-100 0-250 0-250 0-500 0-500 Model 1257 21⁄2" Catalog # 06294 06295 06296 06297 06300 Model 1357 31⁄2" Catalog # 06625 06630 06640 06650 06660 Model 1359 41⁄2" Catalog # 06665 06670 06680 06690 06699 AC Millammeters Range Scale 0-10 0-10 0-50 0-50 0-100 0-100 0-250 0-250 0-500 0-500 Model 2152 21⁄2" Catalog # 17680 17681 17682 17683 17684 Model 2153 31⁄2" Catalog # — 17716 17717 17718 17719 Model 2154 41⁄2" Catalog # 17760 17761 17762 17763 17764 * External multipliers are furnished on AC meters having a range of 500 volts or higher. ** These meters require an external current transformer. 65 Jewell AC Current and Voltage Meters SPECIFICATIONS Modutec S & W Series L • Five Display Sizes: 11/2", 21/2", 31/2", 41/2" and 51/2" • Shielded Taut-Band Movement • Surface-Mount or Window-Mount Models S Series Model W Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.77 x 2.26 x 1.83" 2.29 x 3.01 x 2.10" 2.90 x 3.73 x 2.12" 4.06 x 5.18 x 2.17" 4.60 x 5.97 x 2.17" Window (cutout) 0.935 x 2.15" 1.27 x 2.90" 1.595 x 3.61" 2.345 x 5.02" 2.59 x 5.78" Model S Series Case Size 11/2" 21/2" 31/2" 41/2" 51/2" Size (H x W x D) 1.75 x 2.24 x 1.55" 2.27 x 2.99 x 1.80" 2.87 x 3.70 x 1.80" 3.96 x 5.10 x 1.80" 4.48 x 5.85 x 1.80" Barrel (cutout) 1.55" 2.22" 2.82" 2.82" 2.82" All Models: Scale Length (Rect/Iron) 1.75" 2.41"/2.15" 3.0"/2.7" 4.22"/3.8" 5.12"/--Accuracy ±2% iron vane type, ±3% AC rectifier type (60 Hz sinewave) Repeatability ±2% iron vane, ±0.5% rectifier type Response Time 1.5 sec. (except 3 sec. for <50µA full scale) ORDERING CODE GUIDE W Series Custom Scaling Mirror Scale High Torque Movement Color Bands Illumination Custom Artwork Sealed Case Bezel Mount Kit Also Available: VU Meters & Elapsed Time Meters These meters are available in both moving coil (rectifier type) and iron vane versions. The iron vane construction is relatively insensitive to input distortion. The rectifier type is less affected by frequency variations. ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 and Model Code in box 2 . AC Voltme ter s – Self-cont ained, r ectif ier type, 900Ω/V 1 2 0-3 -AVV-003 1 2 0-5 -AVV-005 1 2 0-10 -AVV-010 1 2 0-15 -AVV-015 1 2 0-25 -AVV-025 1 2 0-50 -AVV-050 1 2 0-100 -AVV-100 1 2 0-150 -AVV-150 1 2 0-300 -AVV-300 1 2 0-500 -AVV-500 1 2 0-600 -AVV-600 AC Voltme ter s – Transf or mer r at ed, 0-150V, r ectif ier type 1 2 0-750 -AVV-750 1 2 0-1500 -AVV-1500 1 2 0-3000 -AVV-3000 AC Voltme ter s – Ir on vane: self-cont ained, 60Hz nominal 1 2 0-3 -AVC-003 ** 1 2 0-5 -AVC-005 ** 1 2 0-10 -AVC-010 ** 1 2 0-15 -AVC-015 ** 1 2 0-30 -AVC-030 ** 1 2 0-50 -AVC-050 ** 1 2 0-100 -AVC-100 ** 1 2 0-150 -AVC-150 ** 1 2 0-300 -AVC-300 ** 1 2 0-500 -AVC-500 ** 1 2 0-600 -AVC-600 ** AC Voltme ter s – Ir on vane: tr ansf or mer r at ed, 0-150V, 60Hz 1 2 0-600 -AVCX-600 ** 1 2 0-750 -AVCX-750 ** 1 2 0-1500 -AVCX-1500 ** 1 2 0-3000 -AVCX-3000 ** ORDERING INFORMATION AC Milliamme ter s – Self-cont ained, r ectif ier type 1 2 0-1 1100W -AMA-001 1 2 0-5 260 -AMA-005 1 2 0-10 140 -AMA-010 1 2 0-25 90 -AMA-025 1 2 0-50 45 -AMA-050 1 2 0-100 6.0 -AMA-100 1 2 0-200 1.5 -AMA-200 * 1 2 0-500 .4 -AMA-500 * AC Milliamme ter s – Ir on vane: Self-cont ained, 60Hz nominal input (50-400Hz r ange) 1 2 0-10 2600 -AMC-010 ** 1 2 0-25 430 -AMC-025 ** 1 2 0-50 105 -AMC-050 ** 1 2 0-100 27 -AMC-100 ** 1 2 0-250 4.3 -AMC-250 ** 1 2 0-500 1.1 -AMC-500 ** AC Amme ter s – Self-cont ained, r ectif ier type 1 2 0-1 .07 -AAA-001 * 1 2 0-1.5 .05 -AAA-0015 * 1 2 0-2 .04 -AAA-002 * 1 2 0-3 .025 -AAA-003 * 1 2 0-5 .015 -AAA-005 * 1 2 0-10 .0075 -AAA-010 * 1 2 0-15 .005 -AAA-015 * 1 2 0-20 .004 -AAA-020 * 1 2 0-25 .0037 -AAA-025 * 1 2 0-30 .0025 -AAA-030 * 1 2 0-50 .0015 -AAA-050 * AC Amme ter s – Ir on vane: Self-cont ained, 60Hz nominal input (50-400Hz r ange) 1 2 0-1 .26 -AAC-001 ** 1 2 0-1.5 .12 -AAC-0015 ** 1 2 0-2 .07 -AAC-002 ** 1 2 0-3 .048 -AAC-003 ** 1 2 0-5 .022 -AAC-005 ** 1 2 0-10 .005 -AAC-010 ** 1 2 0-15 .003 -AAC-015 ** 1 2 0-20 .002 -AAC-020 ** 1 2 0-25 .002 -AAC-025 ** 1 2 0-30 .0015 -AAC-030 ** 1 2 0-50 .001 -AAC-050 ** Insert Size Code: CASE SIZE 1 11/2" 2 21/2" 3 31/2" 4 41/2" 5 51/2" 2 Insert Model Code: STYLE S Surface Mount W Window Mount 1 AC Amme ter s – Transf or mer r at ed, 0-5A , r ectif ier type 1 2 0-60 -AAAX-060 * 1 2 0-75 -AAAX-075 * 1 2 0-100 -AAAX-100 * 1 2 0-150 -AAAX-150 * 1 2 0-200 -AAAX-200 * 1 2 0-300 -AAAX-300 * 1 2 0-400 -AAAX-400 * 1 2 0-500 -AAAX-500 * 1 2 0-600 -AAAX-600 * 1 2 0-800 -AAAX-800 * 1 2 0-1000 -AAAX-1000 * 1 2 0-1500 -AAAX-1500 * 1 2 0-2000 -AAAX-2000 * AC Amme ter s – Ir on vane: Transf or mer r at ed, 0-5A , 60Hz nominal input (50-400Hz r ange) 1 2 0-60 -AACX-060 ** 1 2 0-75 -AACX-075 ** 1 2 0-100 -AACX-100 ** 1 2 0-150 -AACX-150 ** 1 2 0-200 -AACX-200 ** 1 2 0-300 -AACX-300 ** 1 2 0-500 -AACX-500 ** 1 2 0-600 -AACX-600 ** 1 2 0-800 -AACX-800 ** 1 2 0-1000 -AACX-1000 ** 1 2 0-1500 -AACX-1500 ** 1 2 0-2000 -AACX-2000 ** Frequency Me ter s – Point er Type Electr onic 1 2 45-65 Hz 120V -FRQ-55/120-20 ** 1 2 45-55 120 -FRQ-50/120-10 ** 1 2 55-65 120 -FRQ-60/120-10 ** 1 2 380-420 120 -FRQ-400/120-40 ** 1 2 45-55 230 -FRQ-50/230-10 ** 1 2 55-65 230 -FRQ-60/230-10 ** *not available in 11/2" size **not available in 11/2" or 51/2" sizes 66 ANALOG METERS L OPTIONS (WHERE APPLICABLE) Jewell AC Current and Voltage Meters Modutec PB Series • Four Display Sizes: 1½", 2½", 3½", and 4½" • Shielded Taut-Band Movement • Large, Easy to Read Scale SPECIFICATIONS Model Case Size Size (H x W x D) Barrel (cutout) Scale Length Accuracy Repeatability Response Time 1½" 1.75 x 1.75 x 1.39" 1.53" 1.26" PB Series 2½" 3½" 2.70 x 2.70 x 1.77" 3.50 x 3.50 x 1.77" 2.20" 2.75" 2.10" 2.90" 4½" 4.41 x 4.85 x 1.84" 2.79" 4.00" ±2% iron vane type, ±3% AC rectifier type (60 Hz sinewave) ±2% iron vane, ±0.5% rectifier type 1.5 sec. (except 3 sec. for <50μA full scale) The PB series industrial panel board meters meet or exceed the requirements of ANSI C39.1. The mounting stud configuration complies with ANSI standards. Number of studs varies by size: 1½" meters - 2 studs; 2½" & 3½" meters - 3 studs; 4½" meters - 4 studs. ORDERING CODE GUIDE OPTIONS (WHERE APPLICABLE) PB Series Custom Scaling Mirror Scale High Torque Movement Color Bands Custom Artwork Heavy Damping Also Available: VU Meters & Elapsed Time Meters These meters are available in both moving coil (rectifier type) and iron vane versions. The iron vane construction is relatively insensitive to input distortion. The rectifier type is less affected by frequency variations. ORDERING INFORMATION Use Ordering Code Guide to complete Part #. Insert Size Code in box 1 . AC Voltmeters – Self-contained, rectifier type, 900Ω/V 1 PB-AVV-003 0-3 1 PB-AVV-005 0-5 1 PB-AVV-010 0-10 1 PB-AVV-015 0-15 1 PB-AVV-025 0-25 1 PB-AVV-050 0-50 1 PB-AVV-100 0-100 1 PB-AVV-150 0-150 1 PB-AVV-300 0-300 1 PB-AVV-500 0-500 1 PB-AVV-600 0-600 AC Voltmeters – Transformer rated, 0-150V, rectifier type 1 PB-AVVX-750 0-750 1 PB-AVVX-1500 0-1500 1 PB-AVVX-3000 0-3000 AC Voltmeters – Iron vane: self-contained, 60Hz nominal 1 PB-AVC-003 * 0-3 1 PB-AVC-005 * 0-5 1 PB-AVC-010 * 0-10 1 PB-AVC-015 * 0-15 1 PB-AVC-030 * 0-30 1 PB-AVC-050 * 0-50 1 PB-AVC-100 * 0-100 1 PB-AVC-150 * 0-150 1 PB-AVC-300 * 0-300 1 PB-AVC-500 * 0-500 1 PB-AVC-600 * 0-600 AC Voltmeters – Iron vane: transformer rated, 0-150V, 60Hz 1 PB-AVCX-600 * 0-600 1 PB-AVCX-750 * 0-750 1 PB-AVCX-1500 * 0-1500 1 PB-AVCX-3000 * 0-3000 1 Insert Size Code: 1 2 3 4 CASE SIZE 1½" 2½" 3½" 4½" ORDERING INFORMATION AC Milliammeters – Self-contained, rectifier type 1 PB-AMA-001 0-1 1100 Ω 1 PB-AMA-005 0-5 260 1 PB-AMA-010 0-10 140 1 PB-AMA-025 0-25 90.0 1 PB-AMA-050 0-50 45.0 1 PB-AMA-100 0-100 6.0 1 PB-AMA-200 0-200 1.5 1 PB-AMA-500 0-500 .4 AC Milliammeters – Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) 1 PB-AMC-010 * 0-10 2600 1 PB-AMC-025 * 0-25 430 1 PB-AMC-050 * 0-50 105 1 PB-AMC-100 * 0-100 27 1 PB-AMA-250 * 0-250 4.3 1 PB-AMC-500 * 0-500 1.1 AC Ammeters – Self-contained, rectifier type 1 PB-AAA-001 * 0-1 .07 1 PB-AAA-0015 * 0-1.5 .05 1 PB-AAA-002 * 0-2 .04 1 PB-AAA-003 * 0-3 .025 1 PB-AAA-005 * 0-5 .015 1 PB-AAA-010 * 0-10 .0075 1 PB-AAA-015 * 0-15 .005 1 PB-AAA-020 * 0-20 .004 1 PB-AAA-025 * 0-25 .0037 1 PB-AAA-030 * 0-30 .0025 1 PB-AAA-050 * 0-50 .0015 AC Ammeters – Iron vane: Self-contained, 60Hz nominal input (50-400Hz range) 1 PB-AAC-001 * 0-1 .20 1 PB-AAC-0015 * 0-1.5 .012 1 PB-AAC-002 * 0-2 .07 1 PB-AAC-003 * 0-3 .048 1 PB-AAC-005 * 0-5 .022 1 PB-AAC-010 * 0-10 .005 1 PB-AAC-015 * 0-15 .003 1 PB-AAC-020 * 0-20 .002 1 PB-AAC-025 * 0-25 .002 1 PB-AAC-030 * 0-30 .0015 1 PB-AAC-050 * 0-50 .001 ORDERING INFORMATION AC Ammeters – Transformer rated, 0-5A, rectifier type 1 PB-AAAX-060 0-60 1 PB-AAAX-075 0-75 1 PB-AAAX-100 0-100 1 PB-AAAX-150 0-150 1 PB-AAAX-200 0-200 1 PB-AAAX-300 0-300 1 PB-AAAX-400 0-400 1 PB-AAAX-500 0-500 1 PB-AAAX-600 0-600 1 PB-AAAX-800 0-800 1 PB-AAAX-1000 0-1000 1 PB-AAAX-1500 0-1500 1 PB-AAAX-2000 0-2000 AC Ammeters – Iron vane: Transformer rated, 0-5A, 60Hz nominal input (50-400Hz range) 1 PB-AACX-060 * 0-60 1 PB-AACX-075 * 0-75 1 PB-AACX-100 * 0-100 1 PB-AACX-150 * 0-150 1 PB-AACX-200 * 0-200 1 PB-AACX-300 * 0-300 1 PB-AACX-500 * 0-500 1 PB-AACX-600 * 0-600 1 PB-AACX-800 * 0-800 1 PB-AACX-1000 * 0-1000 1 PB-AACX-1500 * 0-1500 1 PB-AACX-2000 * 0-2000 Frequency Meters – Pointer Type Electronic 1 PB-55/120-20 * 45-65 Hz 120V 1 PB-50/120-10 * 45-55 120 1 PB-60/120-10 * 55-65 120 1 PB-400/120-10 * 380-420 120 1 PB-50/230-10 * 45-55 230 1 PB-60/230-10 * 55-65 230 *not available in 1½" size 66a