construction plans for maplecrest skate park
Transcription
construction plans for maplecrest skate park
CONSTRUCTION PLANS FOR MAPLECREST SKATE PARK IMPROVEMENTS PROJECT LOCATION SUSSEX PASSAIC BERGEN WARREN MORRIS ESSEX HUDSON UNION HUNTERDON SOMERSET TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY MIDDLESEX MERCER MONMOUTH BURLINGTON GLOUCESTER OCEAN CAMDEN SALEM ATLANTIC INDEX OF DRAWINGS CUMBERLAND CAPE MAY SHEET TITLE REVISION 1 COVER SHEET - 2 LEGEND, GENERAL NOTES & QUANTITIES - 3 EXISTING CONDITIONS & DEMOLITION PLAN - 4 SITE LAYOUT PLAN - 5 SITE GRADING & DRAINAGE PLAN - 6 FOUNDATION LAYOUT & GRADING PLAN - 7 CONSTRUCTION DETAILS - 8 SOIL EROSION & SEDIMENT CONTROL PLAN - 9 SOIL EROSION & SEDIMENT CONTROL NOTES & DETAILS - STATE OF NEW JERSEY PROJECT LOCATION UTILITIES PSE&G PSE&G VERIZON NEW JERSEY NEW JERSEY AMERICAN WATER SOURCE: GOOGLE MAPS 2014 CONSTRUCTION PLANS FOR MAPLECREST SKATE PARK IMPROVEMENTS KEY MAP 1500 0 1500 3000 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY 4500 SCALE: 1"= 1500' COVER SHEET NOTE: PRIOR TO ANY EXCAVATION, CONTRACTOR MUST HAVE ALL UTILITIES MARKED OUT BY THE APPROPRIATE UTILITY COMPANIES -> 1-800-272-1000 JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. NEW JERSEY LICENSED LANDSCAPE ARCHITECT LICENSE NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 1-xx-2015 DATE: 1-xx-2015 - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 1704 Maxwell Dr., Suite 304 , Wall, N.J. 07719 732.282.1776 www.suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 DATE: PROJECT NUMBER: SCE-7733 SHEET 1 OF 9 REVISIONS: REVISION - LEGEND GENERAL NOTES: EXISTING PROPOSED W W WATER MAIN (SIZES) G G T U/G T GAS MAIN (SIZES) UNDERGROUND FIBER OPTIC T O/H T O/H E E O/H E O/H E EXIST. DOT BOX PROP. 1. ALL LOCATIONS AND ELEVATIONS ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL INFORMATION AND REPORT ALL DISCREPANCIES AT THE TIME OF BID. 2. THE CONTRACTOR SHALL PROVIDE ALL TOOLS, TRANSPORTATION, MATERIALS, LABOR, INSURANCE, AND ALL ELSE NECESSARY FOR THE WORK AND/OR INCIDENTAL THERETO. 3. ADEQUATE WARNING SIGNS AND BARRICADES SHALL BE PLACED AROUND ALL EXCAVATIONS. FLASHING LIGHTS OR OTHER ILLUMINATION DEVICES SHALL BE EMPLOYED TO WARN MOTORISTS AND PEDESTRIANS AFTER DARK. ALL TRAFFIC CONTROL MEASURES SHALL MEET THE REQUIREMENTS OF THE N.J.D.O.T. REGULATIONS AND THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" CURRENT EDITION. 4. ALL EXISTING SIGNS SHALL BE REMOVED STORED AND RESET EACH DAY DURING CONSTRUCTION. DAMAGE TO SIGNS BY CONTRACTOR SHALL REQUIRE REPLACEMENT WITH NEW SIGNS AT HIS OWN EXPENSE. 5. WHENEVER THE DRAWINGS INDICATE TO MEET EXISTING CONDITIONS, THE CONTRACTOR SHALL PROVIDE FOR A SMOOTH AND CONTINUOUS TRANSITION FROM PROPOSED TO EXISTING GRADES TO THE ACCEPTANCE OF THE ENGINEER. 6. THE PROPOSED ELEVATIONS SHOWN IN THE PLANS SHALL BE SUBJECT TO CHANGE AS DIRECTED BY THE ENGINEER TO MEET THE EXISTING CONDITIONS. 7. WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS. 8. WORK MAY BE PERFORMED MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 7:00 AM AND 5:00 PM. NO WORK SHALL OCCUR ON SATURDAYS, SUNDAYS AND HOLIDAYS UNLESS APPROVED BY THE OWNER & THE ENGINEER/LANDSCAPE ARCHITECT. THE COST FOR INSPECTION SERVICES BY THE ENGINEER BEYOND NORMAL WORK DAYS AND HOURS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 9. THE EXISTENCE OF UNDERGROUND UTILITIES ARE KNOWN IN THE PROJECT AREA. THE CONTRACTOR SHALL NOT PROCEED WITH ANY EXCAVATION UNTIL HE HAS CONTACTED EACH OF THE UTILITY COMPANIES, MUNICIPAL AUTHORITIES, AND THE OWNER TO DETERMINE THE EXACT LOCATION OF ALL UTILITIES. THIS SHALL INCLUDE THE "MARKING OUT" OF PHYSICAL LOCATION OF EACH UTILITY. OVERHEAD TELEPHONE WIRE UNDERGROUND ELECTRICAL CONDUIT OVERHEAD DOT BOX ELECTRICAL CONDUIT, HIGHWAY E STORM DRAINS SANITARY SEWERS FMS FMS FMS FORCE MAINS FMS PAVEMENT SHOULDERS SLOPES (F) (C) (F) (C) WETLAND BUFFER CENTER LINE OR BASELINE 10+00 10+00 // NO ACCESS // TWP., CITY, COUNTY LINES PROPERTY LINES CURB LINES X X X X X FENCES (MTL.) X FENCES (WD.) GUIDE RAIL (STL.) 13. THIS PLAN DOES NOT CERTIFY TO THE LOCATION, BOTH HORIZONTAL AND VERTICAL, OF ANY UNDERGROUND FEATURE OR STRUCTURE WHICH HAS NOT BEEN EXPOSED FOR DIRECT MEASUREMENT. THE CONTRACTOR SHALL BE RESPONSIBLE TO PERFORM TEST PITS AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER PRIOR TO CONSTRUCTION ACTIVITIES TO VERIFY LOCATIONS OF UTILITIES. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. GUIDE RAIL (WD.) RETAINING WALL (ROCK) EXIST. RESET RECONSTRUCT 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER DISPOSAL OF ALL WASTE MATERIAL IN ACCORDANCE WITH GOVERNING REGULATIONS AND THE PROJECT SPECIFICATIONS. PROP. 15. ALL QUANTITIES DEPICTED ON THESE PLANS ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL QUANTITIES AND BRING DISCREPANCIES TO THE ATTENTION OF THE ENGINEER PRIOR TO BID PROPOSAL SUBMISSION. FORMAL CHANGE ORDERS SHALL BE APPROVED PRIOR TO ANY ITEM INCREASE. WORK PERFORMED PRIOR TO A CHANGE ORDER WILL NOT BE THE RESPONSIBILITY OF THE OWNER. "A" INLETS "B" INLETS "E" INLETS 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFE ACCESS TO ALL PARK FACILITIES, WALKS AND BUILDINGS AND PROVIDE ADEQUATE MEASURES TO PREVENT NON-AUTHORIZED PERSONNEL FROM ACCESSING THE SITE DURING CONSTRUCTION. SHOULD WORK HOURS OUTSIDE OF THE DESIGNATED HOURS BE APPROVED BY THE ENGINEER, THE CONTRACTOR SHALL PROVIDE SECURITY FOR ALL EMPLOYEES AND INSPECTORS. MANHOLES NEW MANHOLE CASTING SQUARE FRAME, CIRCULAR COVER CAST IRON EXTENSION RING FOR EXIST. MANHOLES CAST IRON EXTENSION FRAME FOR EXIST. INLETS 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SECURITY DURING THE CONSTRUCTION SEQUENCE. THE CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION FENCE PRIOR TO ANY EXCAVATION AND SHALL MAINTAIN CONTINUOUSLY UNTIL GRADING OPERATIONS ARE COMPLETE. SOIL BORING LOCATIONS 18. THE CONTRACTOR SHALL VERIFY THAT ALL PEDESTRIAN ACCESS IS IN COMPLIANCE WITH ALL AMERICANS WITH DISABILITIES ACT (ADA) REQUIREMENTS AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES PRIOR TO THE INSTALLATION OF ANY IMPROVEMENTS . RADIAL PINS MONUMENTS 19. NO MATERIAL OR EQUIPMENT IS TO BE STORED ON ANY AREA THAT HAS NOT BEEN ESTABLISHED AS A DESIGNATED STAGING AREA. ALL EXCAVATIONS SHALL BE PROTECTED AT THE END OF EACH WORK DAY. THE CONTRACTOR IS RESPONSIBLE FOR SITE SAFETY. STAGING AREAS SHALL BE RESTORED TO PRE-CONSTRUCTION CONDITIONS BY THE CONTRACTOR. IRON PIPE/PIN BLDG. TO BE DEMOLISHED PROP. BLDG. BLDG. TO BE REMOVED AND PAID FOR UNDER CLEARING SITE 20. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ALL LOCAL BUILDING PERMITS. THE OWNER WILL OBTAIN ALL ZONING AND LAND DISTURBANCE PERMITS, IF DEEMED NECESSARY. 21. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE HEALTH AND SAFETY OF THEIR OWN EMPLOYEES, ALL THEIR SUBCONTRACTORS, AND ALL OTHER PERSONNEL ON-SITE DURING WORK ACTIVITIES UNDER THIS CONTRACT. 34. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL APPROPRIATE SAFETY DEVICES AND TRAINING TO ALL WORKERS IN ORDER TO MAINTAIN SAFE CONDITIONS ON THE PROJECT SITE. PROFILE +% BM A MILLING LEVEL LINE BENCHMARK LOCATIONS -% 22. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE INSTALLATION, MAINTENANCE AND REPAIR OF SOIL EROSION AND SEDIMENT CONTROL MEASURES IN ACCORDANCE WITH THE APPROVED SOIL EROSION AND SEDIMENT CONTROL PERMIT. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES OR REMEDIATION REQUIRED DUE TO EROSION OR DOWNSTREAM SEDIMENT DEPOSITION. TEST PIT / SOIL BORING W.V. W.V. WATER VALVE WATER GATE VALVE G.V. G.V. 23. ALL CONSTRUCTION EXCAVATIONS SHALL BE PERFORMED IN ACCORDANCE WITH OSHA REGULATION GUIDELINES. GAS VALVE 24. THE CONTRACTOR SHALL MAKE NO PERMANENT MARKINGS OUTSIDE OF THE WORK AREA. IF MARKINGS OUTSIDE THE WORK AREA ARE REQUIRED FOR ANY REASON, THEY SHALL BE NON-PERMANENT IN NATURE (REMOVABLE STAKES, ETC.). IF ANY PERMANENT MARKINGS ARE MADE OUTSIDE OF THE WORK AREA, THEY SHALL BE REPAIRED IN ACCORDANCE WITH THE ENGINEER'S REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. HYDRANT POLE NO. EXIST. RELOCATED UTILITY POLES PROPOSED SIGNS 25. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION FOR SITE IMPROVEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH: DECIDUOUS TREES -CURRENT, PREVAILING MUNICIPAL AND/OR COUNTY SPECIFICATIONS, STANDARDS AND REQUIREMENTS. -CURRENT, PREVAILING UTILITY COMPANY/AUTHORITY AND OWNER SPECIFICATIONS, STANDARDS AND REQUIREMENTS. CONIFEROUS TREES 26. THE CONTRACTOR IS REQUIRED TO PROTECT THE EXISTING FACILITIES AND UTILITIES DESIGNATED TO REMAIN. PHOTOGRAPHIC EVIDENCE OF THE EXISTING CONDITIONS OF THE ENTIRE SITE MUST BE PERFORMED AND PROVIDED TO THE OWNER PRIOR TO THE INSTALLATION OF IMPROVEMENTS. THE CONTRACTOR IS RESPONSIBLE TO REPAIR ANY DAMAGED AREAS SO THAT THEY MATCH IN ELEVATION, COLOR, AND TEXTURE. CONTRACTOR TO RESTORE ANY UTILITIES DISTURBED BY CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. FLOWERING TREES BUSHES/TREELINE 27. THE CONTRACTOR SHALL NOTIFY THE UNDERSIGNED PROFESSIONAL IMMEDIATELY IF ANY FIELD OR SOIL CONDITIONS ENCOUNTERED DIFFER MATERIALLY FROM THOSE REPRESENTED HEREON. LIGHTS R.C. END SECTION HEADWALL NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. DRAWN BY: JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. DATE: NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 LEGEND, GENERAL NOTES, AND QUANTITIES PROJECT NUMBER: SCE-7733 SCALE: AS NOTED SHEET 2 OF 9 REVISION TO REMAIN TO REMAIN TO REMAIN TO REMAIN TO REMAIN EXISTING SHUFFLEBOARD COURTS TO REMAIN TO REMAIN 12" TWIN TREE TO REMAIN 18" PINE TREE TO REMAIN TO REMAIN EXISTING CONCRETE CURB PORTIONS TO BE REMOVED EXISTING CONCRETE CURB TO REMAIN TO REMAIN TO BE REMOVED AND REINSTALLED EXISTING CONCRETE CURB PORTIONS TO BE REMOVED EXISTING ASPHALT PAVEMENT TO BE REMOVED TO REMAIN EXISTING ASPHALT PAVEMENT (TYP.) TO REMAIN EXISTING ASPHALT PAVEMENT TO BE REMOVED EXISTING CONCRETE CURB PORTIONS TO BE REMOVED EXISTING CONCRETE CURB TO REMAIN TO BE REMOVED AND REINSTALLED EXISTING ASPHALT SIDEWALK TO BE REMOVED EXISTING TRASH RECEPTACLE TO REMAIN EXISTING ASPHALT SIDEWALK TO BE REMOVED SAWCUT EXISTING ASPHALT EDGE FOR REMOVAL TO REMAIN 18" PINE TREE TO REMAIN TO REMAIN SAWCUT EXISTING ASPHALT EDGE FOR REMOVAL NOTES: TO REMAIN 1. 2. SUBJECT PROPERTY IS KNOWN AS LOT 301, BLOCK 31.34 AS SHOWN ON SHEET 23 ON THE TAX MAP OF THE TOWNSHIP OF MAPLEWOOD, ESSEX COUNTY, NEW JERSEY. TO REMAIN THIS MAP AND SURVEY WERE PREPARED FROM INFORMATION FOUND ON THE GROUND. CONDITIONS DEPICTED HEREON PER ACTUAL FIELD INSTRUMENT SURVEY PERFORMED OCTOBER 14, 2014. TO REMAIN 12" PINE TREE 3. LOCATION OF UNDERGROUND UTILITIES, IF DEPICTED, ARE APPROXIMATE. ALL LOCATIONS AND SIZES ARE BASED ON UTILITY MARK-OUTS, ABOVE GROUND STRUCTURES THAT WERE VISIBLE AND ACCESSIBLE AT THE TIME OF THE SURVEY. THE LACK OF UTILITY INFORMATION DOES NOT DENY THE EXISTENCE OF SAMETREE AND 15" CEDAR TO REMAIN SUBURBAN CONSULTING ENGINEERS, INC. DOES NOT GUARANTEE THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA EITHER IN SERVICE OR ABANDONED. REFERENCE TO THE APPROPRIATE UTILITY AUTHORITY SHOULD BE MADE TO VERIFY THE PRESENCE OR ABSENCE OF UTILITIES. 4. HORIZONTAL DATUM BASED ON NAD-83, PER GPS SATELLITE OBSERVATION. 5. VERTICAL DATUM IS BASED ON NAVD-88, PER GPS SATELLITE OBSERVATION. TO REMAIN TO REMAIN TO REMAIN TO REMAIN EXISTING PARKING LOT TO REMAIN 10 0 10 20 30 SCALE: 1" =10' DRAWN BY: NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. DATE: DAREN J. PHIL, P.E. NEW JERSEY PROFESSIONAL LAND SURVEYOR LIC. NO. 24GS03585400 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 EXISTING CONDITIONS AND DEMOLITION PLAN PROJECT NUMBER: SCE-7733 SCALE: 1" = 10' SHEET 3 OF 9 REVISION 9' 15 .6 9. 14 ' 1B 2 1A 18" PINE TREE REINSTALL SALVAGED SIGN "SKATING RULES AND REGULATIONS" WITH NEW POST 12" TWIN TREE R1.83' R1.83' PROPOSED 39 SY TOPSOILING, FERTILIZING, SEEDING, AND MULCHING (BASE BID) PROPOSED SYNTHETIC TURF ISLAND IN LIEU OF TOPSOILING, FERTILIZING SEEDING, AND MULCHING (ALTERNATE BID) 60 14 5' R3.66 PROPOSED 38 CY DGA BASE LAYER, 4" THICK 55 .4 3' 3A .4 03 ' 10 .1 4 13 18 .6 1' 4. 4' R5.49' 10 12 3B R7.77' 11B PROPOSED SCORE JOINT (TYP.) 9 R6.76' 8 R3.2' 5 ' 19.36 R5.69' 7 11A R33.06' ' .33 14 R23.59' 6 1C PROPOSED 1,285 SY TOPSOIL, FERTILIZING, SEEDING, AND MULCHING (TYP.) ' 66.81 PROPOSED SKATE FEATURES (SEE COMPONENT LIST) R5.74' PROPOSED 4,025 SF REINFORCED CONCRETE SIDEWALK, 4" THICK PROPOSED 3 CY SIZE #10 STONE LEVELING COURSE REINSTALL SALVAGED SIGN "SKATING RULES AND REGULATIONS" WITH NEW POST PROPOSED 1 CY DGA BASE LAYER, 4" THICK 18" PINE TREE LEGEND 2 30" PINE TREE SKATE PARK COMPONENT CALLOUT NOTES: 1. 2. RAMP COMPONENTS #1A, #1B, & #1C TO RECEIVE POOL COPING. ALL OTHER COMPONENTS TO RECEIVE S.S. EDGE PROTECTION. NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SECURITY DURING CONSTRUCTION. TEMPORARY CONSTRUCTION FENCE AND GATES SHALL BE INSTALLED PRIOR TO POURING OF CONCRETE WORK. CONTRACTOR SHALL SECURE GATES AT THE END OF EACH WORK DAY DURING CONSTRUCTION SEQUENCE. 2. SCORING PATTERN TO BE FURNISHED BY CONTRACTOR PRIOR TO CONCRETE POUR. ALTERNATE SCORE JOINTS AND CONTROL JOINTS. CONTROL JOINTS 12' O.C. MAX. 3. SKATE PARK COMPONENTS WILL BE INSTALLED BY OTHERS DURING PROJECT CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH OWNER FOR SITE STORAGE (IF NEEDED) AND SCHEDULING OF INSTALLATION. (SEE FOUNDATION LOCATION PLAN FOR ADDITIONAL INFORMATION). 4. ALL SITE AMENITIES SHALL BE ANCHORED TO CONCRETE SIDEWALK OR PAD WITH STAINLESS STEEL TAMPER RESISTANT HARDWARE. COMPONENT 12" PINE LIST TREE - ALL DIMS ARE NOMINAL REF# DESCRIPTION CODE QTY 1 7'R FLOATING RAMP 8'-1"L x 15'-8"W x 4'H 3 2 35 BANK 9'-6"L x 15'-8"W x 4'H 1 3 FLOATING BANK 15" CEDAR TREELAUNCH 6'-1"L x 5'W x 1'-6"H 2 4 PARK BENCH 8'L x 1'-8"W x 1'-5"H 1 5 LA HIGHWALL 15'-3"L x 3'-8"W x 2'-8"H 1 6 MANUAL PAD 15'L x 3'-9"W x 1'H 1 7 20 BANK 8'-8"L x 13'-9"W x 2'-8"H 1 8 20 BANK 8'-8"L x 9'-11"W x 2'-8"H 1 9 STAIRS 5'-11"L x 8'-3"W x 2'-8"H 1 10 20 BANK 8'-8"L x 8'-1"W x 2'-8"H 1 11 HUBBA 15'-8"L x 1'-6"W x 4'-5"H 2 12 FLAT DOWN RAIL 9'-2"L x 2"W x 4'-9"H 1 13 FLAT DOWN RAIL 9'-2"L x 2"W x 4'-9"H 1 14 TALL RAIL 12'L x 2"W x 1'-4"H 1 S.S. COPING 48ft. S.S. 2"x2" EDGE PROTECTION 90ft. S.S. 2"x6" EDGE PROTECTION 9ft. 10 0 10 20 30 SCALE: 1" =10' DRAWN BY: MRS DATE: 5-23-2014 NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. JOSEPH D. PERELLO, L.L.A. NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 CHECKED BY: JP DATE: 5-23-2014 THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 SITE LAYOUT PLAN PROJECT NUMBER: SCE-7733 SCALE: 1" = 10' SHEET 4 OF 9 REVISION 228.01 228.11 PROPOSED INVERT 6" HDPE: 224.02 228.09 228 228.04 227.98 228.18 18" PINE TREE 12" TWIN TREE 22 7 228.13 228.23 228.12 228.16 228.40 228.22 228.13 228.15 228.16 231.16 228.23 228.44 228.25 228.19 228.46 231.22 22 8 228.21 228.40 228.23 231.19 228.48 231.33 228.29 228.28 231.44 PROPOSED 70 LF 6" SOLID HDPE @ 2% 228.41 228.36 228.38 228.44 228.50 231.23 228.52 231.26 228.24 228.41 23 1 231.33 231.50 0 231.38 22 9 228.65 23 228.32 228.65 228.59 228.66 228.63 228.55 228.65 228.61 228.48 PROPOSED 18" SQUARE CATCH BASIN GRATE: 227.56 INV.: 225.40 228.58 228.54 HPS 228.35 PROPOSED 18" SQUARE CATCH BASIN GRATE: 228.25 INV.: 226.09 PROPOSED 70 LF 6" SOLID HDPE @ 1% PROPOSED 18" SQUARE CATCH BASIN GRATE: 228.02 INV.: 225.86 18" PINE TREE 30" PINE TREE PROPOSED 28 LF 6" SOLID HDPE @ 0.75% 12" PINE TREE 15" CEDAR TREE 10 0 10 20 30 SCALE: 1" =10' NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. DRAWN BY: JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. DATE: NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 SITE GRADING AND DRAINAGE PLAN PROJECT NUMBER: SCE-7733 SCALE: 1" = 10' SHEET 5 OF 9 REVISION 227.64 227.70 227.68 11 .6 9' 10 227.69 ' 227.78 A 15 .7 4' 227.69 227.63 A 227.65 227.75 227.76 227.71 15.7' 227.91 C C 227.81 5. 5. 1 3' 02 ' 227.83 227.83 227.85 228.91 227.90 228.95 1. D ' ' C 15.27 228.05 228.08 228.17 230.86 D 230.90 230.93 3.65' 228.11 A 13.77' 9' 6.6 231.03 231.00 .69 15 ' 228.03 B 228.25 1 A 3.48' 228.15 228.15 228.17 228.33 231.05 ' 17.46 C 228.29 228.22 228.12 227.13 C 4.53' 1.5' 228.32 228.02 C 228.19 228.08 227.99 227.99 230.89 230.90 228.15 65 230.83 ' 228.11 228.96 227.90 6' 228.13 9.45' A 5. 02 ' .4 8. 227.86 227.86 228.92 02 ' 5. 227.84 227.88 17 228.08 22 .4 9' 13 ' B 228.07 228.07 26 .1 2' 227.82 A 1. 53 227.81 227.85 227.86 227.85 227.87 B 11 7.94' 227.63 227.68 A 9' 227.67 15 .7 4' 227.74 227.79 227.80 A .6 227.62 227.58 228.26 A C PRE-CAST CANTILEVER PROFILE II N.T.S. #3 REBAR @ 16" O.C. BOTH WAYS 4000 PSI CONCRETE FLAT WORK 1/8" SAW CUT - FILL JOINT WITH SELF LEVELING SEALANT AND TOOL FLAT (SUPPLIED BY PRE-CAST MANUFACTURER) 6"x 6"x 10"/10 WELDED WIRE MESH 1/3 DEPTH COLD JOINT 6" 6" 4" 4" 4" 5" 4" 2 7/8" 4000 PSI CONCRETE FLAT WORK BASE COURSE BASE COURSE SAWCUT JOINT PREPARED SUB-GRADE PREPARED SUB-GRADE N.T.S. CONCRETE SKATE ELEMENT PRE-CAST SKATE ELEMENT COLD JOINT 1. ALL DIMENSIONS APPROXIMATE. SUCCESSFUL BIDDER WILL BE FURNISHED WITH SHOP DRAWINGS BY SPOHN RANCH, 15131 CLARK AVE., INDUSTRY, CA 91745. CONTRACTOR SHALL REFER TO MANUFACTURER'S SHOP DRAWINGS FOR FINAL LAYOUT DIMENSIONS AND CONNECTION DETAILS. 1.1. AREA REPRESENTATIVE: JASON BALDESSARI (732)-687-5886 1.2. CONSTRUCTION MANAGER: DOUG HAGAN (919)-615-2305 2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION. 3. CONTRACTOR SHALL COORDINATE DELIVERY AND STORAGE ON SITE OF ALL CONCRETE SKATE FEATURES WITH OWNER AND SPOHN RANCH. 4. CONTRACTOR SHALL COORDINATE WITH OWNER AND SPOHN RANCH FOR CONCRETE SKATE FEATURE INSTALLATION. 5. ELEVATIONS SHOWN ON PLAN ARE FINISHED FOUNDATION ELEVATION. 10 20 SLIP DOWEL 4000 PSI CONCRETE FLAT WORK 30 SCALE: 1" =10' 4,000 PSI CONCRETE FLAT WORK 2" 6x6 x 10/10 WELDED WIRE MESH BASE COURSE PREPARED SUB-GRADE 3" 4000 PSI CONCRETE FOOTING WITH #3 REBAR @ 16" O.C. BOTH WAYS 8" PREPARED SUB-GRADE VIBRATE CONCRETE TO PRODUCE EFFECTIVE CONSOLIDATION UNDER PRE-CAST SKATE ELEMENT ADJACENT TO FOOTING NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. D PRE-CAST PROFILE DETAIL N.T.S. DRAWN BY: JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. DATE: NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: SLIP DOWEL 6" 6" 7" BASE COURSE CAPPED 3 9/16" 0 4" NOTES: 10 DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 FOUNDATION LAYOUT AND GRADING PLAN PROJECT NUMBER: SCE-7733 SCALE: 1" = 10' SHEET 6 OF 9 REVISION WIRE MESH 6"X6" 10/10 WWM DEMOLISH EXISTING CURB TO ASPHALT SURFACE 4" THICK AIR ENTRAINED CLASS "B" CONCRETE 4" DENSE GRADED AGGREGATE BASE 1" +/- SIZE #10 CRUSHED STONE OVERLAY EXISTING ASPHALT EXISTING BASE COMPACTED SUBGRADE COMPACTED SUBGRADE 6" x 12" CONCRETE CURB NEW PAVEMENT EXISTING PAVEMENT OVERLAY NOTES: 1. 2. 3. 4. 5. 6. 7. SUBBASE SHALL BE COMPACTED TO THE SATISFACTION OF THE ENGINEER. THE SAME BRAND AND TYPE OF CONCRETE SHALL BE USED THROUGHOUT THE PROJECT. ALL CONCRETE SYSTEM COMPONENTS SHALL BE MANUFACTURED BY L.M. SCOFIELD COMPANY OR APPROVED EQUAL. ALL CONTROL JOINTS SHALL BE 1 4" WIDE X 3 4" DEEPIN A 10' X 10' MAXIMUM GRID (SEE PLAN VIEW FOR GRID LAYOUT). ALL CONTROL JOINTS SHALL BE FILLED WITH TRAFFIC-GRADE ELASTOMETRIC CAULK. ALL CONCRETE SHALL BE CLASS "B" AIR ENTRAINED MINIMUM 4,000 PSI STRENGTH W/ FIBERGLASS REINFORCEMENT. SURFACE SHALL BE HARD STEEL-TROWEL FINISH (JUST BEFORE GLASSY) AND SHALL BE CHEMICALLY SEALED WITH PERMANENT, NON-GLOSSY CONCRETE SEALANT. REINFORCED CONCRETE SIDEWALK, 4" THICK N.T.S. NDS #1242, #1242 & #1245 UNIVERSAL LOCKING OUTLET OR APPROVED EQUAL. TWIST LOCK INTO POSITION AT ANY KNOCK OUT. 6" CLASS "B" CONCRETE COLLAR AROUND CATCH BASIN PERFORATIONS SLOPE NDS #1266 OR #1889 UNIVERSAL LOCKING OUTLET OR APPROVED EQUAL. TWIST LOCK INTO POSITION AT ANY KNOCK OUT. 6" SLOPE 6" CORRUGATED SOLID WALL HDPE PIPE 6" CORRUGATED SOLID WALL HDPE PIPE NDS #1816 18" SQUARE TAPERED POLYPROPYLENE CATCH BASIN (RISER) W / U.V. INHIBITORS OR APPROVED EQUAL CLASS "B" CONCRETE COLLAR AROUND CATCH BASIN NDS #1810 18" SQUARE POLYOLEFIN GRATE W / U.V. INHIBITORS OR APPROVED EQUAL 6" SLOPE 18" SQUARE CATCH BASIN COMPACTED SUBGRADE SLOPE NOTES: 9" DEPTH 6" 1. 2. NDS ADAPTERS THAT FIT THIS BASIN ARE AS FOLLOWS: #1242, #1243, #1245, #1266, 1888, #1889, USE #1206 IF PLUGGING AN OUTLET. PERFORATIONS ON NON OPEN SIDES AND BTM. TO BE CUT OUT WHEN ADDING EXTRA OUTLETS. 3/4" CRUSHED STONE BASE 4" TO 6" DEEP BELOW BASIN 8" DEPTH 18" SQ. CATCH BASIN PLUMBING CONNECTIONS N.T.S. NON-PAVED SURFACE PAVED SURFACE 18 9/16" DEPTH TOPSOIL, FERTILIZE, SEED, & MULCH 3" MIN. NDS #1882 18" SQUARE TAPERED POLYPROPYLENE CATCH BASIN W / U.V. INHIBITORS OR APPROVED EQUAL DRILL 1/8" WEEP HOLE TYPICAL OF 4 PLACES AT BTM CORNERS COMPACTED EXCAVATED BACKFILL (SEE NOTE FOR BACKFILL MATERIAL SPECIFICATION) DENSE GRADED AGGREGATE 3 4 " CLEAN CRUSHED STONE 3/4" CRUSHED STONE BASE 4" TO 6" DEEP BELOW BASIN HDPE PIPE 9" MIN (TYP) TO SPRING LINE 6" MIN. NOTES: 1. 2. 3. GRATE TO BE ATTACHED TO CATCH BASIN WITH SCREW PROVIDED AT TIME OF INSTALLATION. RISER CAN BE CUT TO ACHIEVE EXACT ELEVATION. DO NOT USE OVER 5 RISERS WITH CATCH BASIN. O.D. + 24" MINIMUM 18" SQ. CATCH BASIN WITH RISER INSTALLATION N.T.S. COMPACTED SUBGRADE BACKFILL SPECIFICATION 1. SHALL BE FREE OF DEBRIS AND STONES 2" OR GREATER IN ANY DIMENSION. 2. SHALL BE PLACED IN 12" LIFTS AND COMPACTED TO 95% MAXIMUM DENSITY. SOLID DRAINAGE PIPE TRENCH N.T.S. NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. DRAWN BY: JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. DATE: NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 CONSTRUCTION DETAILS PROJECT NUMBER: SCE-7733 SCALE: AS NOTED SHEET 7 OF 9 REVISION SOIL EROSION AND SEDIMENT CONTROL NOTES 1. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES ON THIS PLAN WILL BE CONSTRUCTED IN ACCORDANCE WITH THE JERSEY STANDARDS FOR SOIL EROSION AND SEDIMENT 7TH EDITION LAST REVISED JANUARY 2014. THESE MEASURES WILL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE OR IN THEIR PROPER SEQUENCE AND MAINTAINED UNTIL PERMANENT PROTECTION IS ESTABLISHED. 2. ALL SOIL TO BE EXPOSED OR STOCKPILED FOR A PERIOD OF GREATER THAN 14 DAYS, AND NOT UNDER ACTIVE CONSTRUCTION, WILL BE TEMPORARILY SEEDED AND HAY MULCHED OR OTHERWISE PROVIDED WITH VEGETATIVE COVER. THIS TEMPORARY COVER SHALL BE MAINTAINED UNTIL SUCH TIME WHEREBY PERMANENT RESTABILIZATION IS ESTABLISHED. PROPOSED TOPSOIL STOCKPILE LOCATION X X 3. SEEDING DATES: THE FOLLOWING SEEDING DATES ARE BEST RECOMMENDED TO ESTABLISH PERMANENT VEGETATIVE COVER WITHIN MOST LOCATIONS IN THE HEPSCD: SPRING - 3/1-5/15 AND FALL - 8/15 - 10/1 X X X X PROPOSED SILT FENCE AT DOWNSLOPE EDGE OF TOPSOIL STOCKPILE 4. SEDIMENT FENCES ARE TO BE PROPERLY TRENCHED AND MAINTAINED UNTIL PERMANENT VEGETATIVE COVER IS ESTABLISHED X X 5. ALL STORM DRAINAGE INLETS SHALL BE PROTECTED BY ONE OF THE PRACTICES ACCEPTED IN THE STANDARDS, AND PROTECTION SHALL REMAIN UNTIL PERMANENT STABILIZATION HAS BEEN ESTABLISHED. STORM DRAINAGE OUTLET POINTS SHALL BE PROTECTED AS REQUIRED BEFORE THEY BECOME FUNCTIONAL. PROPOSED INLET PROTECTION X X 6. MULCH MATERIALS SHALL BE UN-ROTTED SMALL GRAIN STRAW APPLIED AT THE RATE OF 70 TO 90 POUNDS PER 1,000 SQUARE FEET AND ANCHORED WITH A MULCH ANCHORING TOOL, LIQUID MULCH BINDERS, OR NETTING TIE DOWN. OTHER SUITABLE MATERIALS MAY BE USED IF APPROVED BY THE SOIL CONSERVATION DISTRICT. X X X 7. ALL EROSION CONTROL DEVICES SHALL BE PERIODICALLY INSPECTED, MAINTAINED AND CORRECTED BY THE CONTRACTOR. ANY DAMAGE INCURRED BY EROSION SHALL BE RECTIFIED IMMEDIATELY. X 228 8. THE HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT WILL BE NOTIFIED IN WRITING AT LEAST 48 HOURS PRIOR TO ANY SOIL DISTURBING ACTIVITIES. FAX - (973) 364-0784 OR EMAIL [email protected] 7 9. THE APPLICANT MUST OBTAIN A DISTRICT ISSUED REPORT-OF-COMPLIANCE PRIOR TO APPLYING FOR THE CERTIFICATE OF OCCUPANCY OR TEMPORARY CERTIFICATE OF OCCUPANCY FROM THE RESPECTIVE MUNICIPALITY, NJ - DCA OR ANY OTHER CONTROLLING AGENCY. CONTACT THE DISTRICT AT 973-364-0786 TO REQUEST A FINAL INSPECTION, GIVING ADVANCED NOTICE UPON COMPLETION OF THE RESTABILIZATION MEASURES. A PERFORMANCE DEPOSIT MAY BE POSTED WITH THE DISTRICT WHEN WINTER WEATHER OR SNOW COVER PROHIBITS THE PROPER APPLICATION OF SEED, MULCH, FERTILIZER OR HYDRO-SEED. 22 EXISTING LAWN PROPOSED LAWN 10. PAVED ROADWAYS MUST BE KEPT CLEAN AT ALL TIMES. DO NOT UTILIZE A FIRE OR GARDEN HOSE TO CLEAN ROADS UNLESS THE RUNOFF IS DIRECTED TO A PROPERLY DESIGNED AND FUNCTIONING SEDIMENT BASIN. WATER PUMPED OUT OF THE EXCAVATED AREAS CONTAINS SEDIMENTS THAT MUST BE REMOVED PRIOR TO DISCHARGING TO RECEIVING BODIES OF WATER USING REMOVABLE PUMPING STATIONS, SUMP PITS, PORTABLE SEDIMENTATION TANKS AND/OR SILT CONTROL BAGS. LIMIT OF EXISTING SKATE PARK PAVEMENT EXISTING LAWN PROPOSED LAWN 11. ALL SURFACES HAVING LAWN OR LANDSCAPING AS FINAL COVER ARE TO BE PROVIDED TOPSOIL PRIOR TO RE-SEEDING, SODDING OR PLANTING. A DEPTH OF 5 INCHES (UNSETTLED) IS RECOMMENDED. 22 8 PROPOSED SILT FENCE AT DOWNSLOPE EDGE OF DISTURBANCE PROPOSED CAUTION FENCE AT SITE PERIMETER PROPOSED SKATE PARK PROPOSED STABILIZED CONSTRUCTION ENTRANCE 12. ALL PLAN REVISIONS MUST BE SUBMITTED TO THE DISTRICT FOR PROPER REVIEW AND APPROVAL. PROPOSED SILT FENCE 1 EXISTING SKATE PARK PROPOSED SKATE PARK 22 9 23 0 23 13. A CRUSHED STONE WHEEL CLEANING TRACKING-PAD IS TO BE INSTALLED AT ALL SITE EXITS USING 2 ANGULAR STONE (ASTM 2 OR 3) TO A MINIMUM LENGTH OF 50 FEET AND MINIMUM DEPTH OF ALL DRIVEWAYS MUST BE PROVIDED WITH CRUSHED STONE UNTIL PAVING IS COMPLETE. 14. STEEP SLOPES INCURRING DISTURBANCE MAY REQUIRE ADDITIONAL STABILIZATION MEASURES. THESE MEASURES SHALL BE DESIGNED BY THE APPLICANT'S ENGINEER AND BE APPROVED BY THE SOIL CONSERVATION DISTRICT. 15. THE HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT SHALL BE NOTIFIED, IN WRITING, FOR THE SALE OF ANY PORTION OF THE PROJECT OR FOR THE SALE OF INDIVIDUAL LOTS. NEW OWNERS' INFORMATION SHALL BE PROVIDED. ADDITIONAL MEASURES DEEMED NECESSARY BY DISTRICT OFFICIALS SHALL BE IMPLEMENTED AS CONDITIONS WARRANT. SEQUENCE OF CONSTRUCTION LIMIT OF EARTH DISTURBANCE THE CONTRACT LENGTH SHALL BE 80 DAYS (APPROXIMATELY 12 WEEKS). CONTRACT LENGTH SHALL BE THE SAME FOR BASE BID OR BASE BID WITH ALTERNATE. 1. SOIL EROSION AND SEDIMENT CONTROL MEASURES AND CONSTRUCTION ACCESS DRIVE 0.5 WEEKS 2. CLEARING SITE, EXCAVATION AND SUBGRADE PREPARATION 2.5 WEEKS 3. INSTALLATION OF DRAINAGE STRUCTURES AND PIPES INSTALLATION OF SKATE PARK SUBBASE AND FOUNDATIONS 3.5 WEEKS 4. INSTALLATION OF SKATE PARK FEATURES AND CONCRETE SIDEWALKS 3.5 WEEKS 6. SURFACE RESTORATION TOPSOIL, FERTILIZE, SEED AND MULCH 1.5 WEEK 7. DEMOBILIZATION AND REMOVAL OF SOIL EROSION AND SEDIMENT CONTROL MEASURES AND CONSTRUCTION ACCESS DRIVE 0.5 WEEK PROPOSED 18" SQUARE CATCH BASIN (TYP.) 18" PINE TREE PROPOSED 6" HDPE PIPE (TYP.) 12" PINE TREE TOTAL: EXISTING PARKING LOT 12.0 WEEKS LEGEND 10 15" CEDAR TREE 0 10 20 30 PROPOSED LIMIT OF DISTURBANCE SCALE: 1" =10' PROPOSED TEMPORARY CONSTRUCTION FENCE X X PROPOSED SILT FENCE SOIL SERIES BOUNDARY NOTICE PROPOSED INLET PROTECTION THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. DRAWN BY: JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. DATE: NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 SOIL EROSION AND SEDIMENT CONTROL PLAN PROJECT NUMBER: SCE-7733 SCALE: 1" = 10' SHEET 8 OF 9 REVISION SOIL EROSION AND SEDIMENT CONTROL NOTES 1. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES ON THIS PLAN WILL BE CONSTRUCTED IN ACCORDANCE WITH THE JERSEY STANDARDS FOR SOIL EROSION AND SEDIMENT 7TH EDITION LAST REVISED JANUARY 2014. THESE MEASURES WILL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE OR IN THEIR PROPER SEQUENCE AND MAINTAINED UNTIL PERMANENT PROTECTION IS ESTABLISHED. 2. ALL SOIL TO BE EXPOSED OR STOCKPILED FOR A PERIOD OF GREATER THAN 14 DAYS, AND NOT UNDER ACTIVE CONSTRUCTION, WILL BE TEMPORARILY SEEDED AND HAY MULCHED OR OTHERWISE PROVIDED WITH VEGETATIVE COVER. THIS TEMPORARY COVER SHALL BE MAINTAINED UNTIL SUCH TIME WHEREBY PERMANENT RESTABILIZATION IS ESTABLISHED. 3. SEEDING DATES: THE FOLLOWING SEEDING DATES ARE BEST RECOMMENDED TO ESTABLISH PERMANENT VEGETATIVE COVER WITHIN MOST LOCATIONS IN THE HEPSCD: SPRING - 3/1-5/15 AND FALL - 8/15 - 10/1 4. SEDIMENT FENCES ARE TO BE PROPERLY TRENCHED AND MAINTAINED UNTIL PERMANENT VEGETATIVE COVER IS ESTABLISHED 5. ALL STORM DRAINAGE INLETS SHALL BE PROTECTED BY ONE OF THE PRACTICES ACCEPTED IN THE STANDARDS, AND PROTECTION SHALL REMAIN UNTIL PERMANENT STABILIZATION HAS BEEN ESTABLISHED. STORM DRAINAGE OUTLET POINTS SHALL BE PROTECTED AS REQUIRED BEFORE THEY BECOME FUNCTIONAL. MULCH MATERIALS SHALL BE UN-ROTTED SMALL GRAIN STRAW APPLIED AT THE RATE OF 70 TO 90 POUNDS PER 1,000 SQUARE FEET AND ANCHORED WITH A MULCH ANCHORING TOOL, LIQUID MULCH BINDERS, OR NETTING TIE DOWN. OTHER SUITABLE MATERIALS MAY BE USED IF APPROVED BY THE SOIL CONSERVATION DISTRICT. 7. ALL EROSION CONTROL DEVICES SHALL BE PERIODICALLY INSPECTED, MAINTAINED AND CORRECTED BY THE CONTRACTOR. ANY DAMAGE INCURRED BY EROSION SHALL BE RECTIFIED IMMEDIATELY. 8. THE HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT WILL BE NOTIFIED IN WRITING AT LEAST 48 HOURS PRIOR TO ANY SOIL DISTURBING ACTIVITIES. FAX - (973) 364-0784 OR EMAIL [email protected] 9. EXISTING GRADE 6" MIN. DRIP LINE NOTE: SEED IMMEDIATELY AFTER STOCKPILING CLEAN STONE PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND ROADWAY AMOCO MODEL 2002 FILTER FABRIC OR APPROVED EQUAL DOWN G RADE LENGTH ACCORDING TO TABLE BELLOW* CORRECT FENCING FOR TREE PROTECTION R = 25' INCORRECT FENCING FOR TREE PROTECTION SILT FENCE (SEE DETAIL ) TREE PROTECTION TYPICAL TOPSOIL STOCKPILE N.T.S. N.T.S. PUBLIC RIGHT OF WAY EXISTING GRADE THE APPLICANT MUST OBTAIN A DISTRICT ISSUED REPORT-OF-COMPLIANCE PRIOR TO APPLYING FOR THE CERTIFICATE OF OCCUPANCY OR TEMPORARY CERTIFICATE OF OCCUPANCY FROM THE RESPECTIVE MUNICIPALITY, NJ - DCA OR ANY OTHER CONTROLLING AGENCY. CONTACT THE DISTRICT AT 973-364-0786 TO REQUEST A FINAL INSPECTION, GIVING ADVANCED NOTICE UPON COMPLETION OF THE RESTABILIZATION MEASURES. A PERFORMANCE DEPOSIT MAY BE POSTED WITH THE DISTRICT WHEN WINTER WEATHER OR SNOW COVER PROHIBITS THE PROPER APPLICATION OF SEED, MULCH, FERTILIZER OR HYDRO-SEED. 15' MIN. POLYETHYLENE SNOW FENCE AS MANUFACTURED BY TENAX NORDIC II, ORANGE COLOR OR APPROVED EQUAL STEEL U-POST 6'-0" O.C. MIN. 10'-0" O.C. MAX. 10. PAVED ROADWAYS MUST BE KEPT CLEAN AT ALL TIMES. DO NOT UTILIZE A FIRE OR GARDEN HOSE TO CLEAN ROADS UNLESS THE RUNOFF IS DIRECTED TO A PROPERLY DESIGNED AND FUNCTIONING SEDIMENT BASIN. WATER PUMPED OUT OF THE EXCAVATED AREAS CONTAINS SEDIMENTS THAT MUST BE REMOVED PRIOR TO DISCHARGING TO RECEIVING BODIES OF WATER USING REMOVABLE PUMPING STATIONS, SUMP PITS, PORTABLE SEDIMENTATION TANKS AND/OR SILT CONTROL BAGS. R = 25' DANGER KEEP OUT 12. ALL PLAN REVISIONS MUST BE SUBMITTED TO THE DISTRICT FOR PROPER REVIEW AND APPROVAL. 4'-0" MIN. 14" X 10" - 0.060 PLASTIC "DANGER KEEP OUT" SIGNS AS MANUFACTURED BY RAINBOW SIGNS, MODEL NO. 04-240G. ATTACH SIGNS TO FENCE WITH PLASTIC TIES. SPACE SIGNS 50 FEET APART. 11. ALL SURFACES HAVING LAWN OR LANDSCAPING AS FINAL COVER ARE TO BE PROVIDED TOPSOIL PRIOR TO RE-SEEDING, SODDING OR PLANTING. A DEPTH OF 5 INCHES (UNSETTLED) IS RECOMMENDED. 13. A CRUSHED STONE WHEEL CLEANING TRACKING-PAD IS TO BE INSTALLED AT ALL SITE EXITS USING 2 ANGULAR STONE (ASTM 2 OR 3) TO A MINIMUM LENGTH OF 50 FEET AND MINIMUM DEPTH OF ALL DRIVEWAYS MUST BE PROVIDED WITH CRUSHED STONE UNTIL PAVING IS COMPLETE. LENGTH STONE REQUIRED PERCENT SLOPE OF ROADWAY COARSE GRAINED SOILS FINE GRAINED SOILS 0 TO 2% 50 FT. 100 FT. 2 TO 5% 100 FT. 200 FT. > 5% ATTACH FENCE TO POSTS ENTIRE SURFACE STABILIZED WITH FABC BASE COURSE 1 1 AS PRESCRIBED BY LOCAL ORDINANCE OR OTHER GOVERNING AUTHORITY. GROUND LINE 1'-6" MIN 14. STEEP SLOPES INCURRING DISTURBANCE MAY REQUIRE ADDITIONAL STABILIZATION MEASURES. THESE MEASURES SHALL BE DESIGNED BY THE APPLICANT'S ENGINEER AND BE APPROVED BY THE SOIL CONSERVATION DISTRICT. 15. THE HUDSON-ESSEX-PASSAIC SOIL CONSERVATION DISTRICT SHALL BE NOTIFIED, IN WRITING, FOR THE SALE OF ANY PORTION OF THE PROJECT OR FOR THE SALE OF INDIVIDUAL LOTS. NEW OWNERS' INFORMATION SHALL BE PROVIDED. ADDITIONAL MEASURES DEEMED NECESSARY BY DISTRICT OFFICIALS SHALL BE IMPLEMENTED AS CONDITIONS WARRANT. STABILIZED CONSTRUCTION ENTRANCE N.T.S. CAUTION FENCE/TEMPORARY CONSTRUCTION FENCE SHALL BE PROVIDED CONTINUOUSLY AROUND THE CONSTRUCTION SITE PERIMETER AS DIRECTED BY THE ENGINEER. "DANGER-KEEP OUT" SIGNS SHALL BE PROVIDED EVERY 50 FEET ON THE TEMPORARY CONSTRUCTION FENCE. 16. TOTAL AREA OF DISTURBANCE: 0.35 AC (15,242 SF) CAUTION FENCE/TEMPORARY CONSTRUCTION FENCE 2 EACH DUMP STRAPS N.T.S. REQUIREMENTS FOR SILT FENCE: 1. FENCE POSTS SHALL BE SPACED 8 FEET CENTERTO-CENTER OR CLOSER. THEY SHALL EXTEND AT LEAST 2 FEET INTO THE GROUND AND EXTEND AT LEAST 2 FEET ABOVE GROUND. POSTS SHALL BE CONSTRUCTED OF HARDWOOD WITH A MINIMUM DIAMETER THICKNESS OF 1.5 INCHES. DRAWSTRING RUNNING THROUGH FABRIC ALONG TOP OF FENCE 2. A METAL FENCE WITH 6 INCH OR SMALLER OPENINGS AND AT LEAST 2 FEET HIGH MAY BE UTILIZED, FASTENED TO THE FENCE POSTS, TO PROVIDE REINFORCEMENT AND SUPPORT TO THE GEOTEXTILE FABRIC WHERE SPACE FOR OTHER PRACTICES IS LIMITED AND HEAVY SEDIMENT LOADING IS EXPECTED. 8' FENCE POST (SPACING 8'-0" C. TO C.) FABRIC (3'-0" WIDE) SECURED TO POST WITH METAL FASTENERS AND REINFORCEMENT BETWEEN FASTENER AND FABRIC. 3. A GEOTEXTILE FABRIC, RECOMMENDED FOR SUCH USE BY THE MANUFACTURER, SHALL BE BURIED AT LEAST 6 INCHES DEEP IN THE GROUND. THE FABRIC SHALL EXTEND AT LEAST 2 FEET ABOVE THE GROUND. THE FABRIC MUST BE SECURELY FASTENED TO THE POSTS USING A SYSTEM CONSISTING OF METAL FASTENERS (NAILS OR STAPLES) AND A HIGH STRENGTH REINFORCEMENT MATERIAL (NYLON WEBBING, GROMMETS, WASHERS, ETC.) PLACED BETWEEN THE FASTENER AND THE GEOTEXTILE FABRIC. THE FASTENING SYSTEM SHALL RESIST TEARING AWAY FROM THE POST. THE FABRIC SHALL INCORPORATE A DRAWSTRING IN THE TOP PORTION OF THE FENCE FOR ADDED STRENGTH. 2'-0" MIN. GRADE 6" DIG 6" WIDE x 6" DEEP TRENCH, BURY BOTTOM 1'-0" OF FABRIC, TAMP IN PLACE 6" 2'-0" MIN. EXPANSION RESTRAINT (1/4" NYLON ROPE, 2" FLAT WASHERS) DUMP STRAP 1" REBAR FOR BAG REMOVAL FROM INLET DUMP STRAP SILT SACK AS MANUFACTURED BY ATLANTIC CONSTRUCTION FABRICS, INC., RICHMOND, VA. LE N GT H= BAG DETAIL DEPTH = D 6. PUBLIC RIGHT OF WAY STABILIZED CONSTRUCTION ENTRANCE N.T.S. = TH W D WI L INSTALLATION DETAIL INLET PROTECTION DEVICE N.T.S. N.T.S. SEDIMENT FENCE DETAIL N.T.S. NOTICE THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AUTHORIZED FOR USE ONLY BY THE PARTY FOR WHOM THE WORK WAS CONTRACTED OR TO WHOM IT IS CERTIFIED. DRAWN BY: JOSEPH D. PERELLO, L.L.A. DAREN J. PHIL, P.E. DATE: NEW JERSEY LICENSED LANDSCAPE ARCHITECT LIC. NO. AS00666 NEW JERSEY PROFESSIONAL ENGINEER LICENSE NO. 24GE03619100 LOT 301, BLOCK 31.34 TOWNSHIP OF MAPLEWOOD ESSEX COUNTY, NEW JERSEY CHECKED BY: THIS DRAWING MAY NOT BE COPIED, REUSED, DISCLOSED, DISTRIBUTED, OR RELIED UPON FOR ANY OTHER PURPOSE WITHOUT THE WRITTEN CONSENT OF - Civil Engineers - Municipal Engineers - Landscape Architects - Planners - Environmentalists - Land Surveyors - DATE: CHECKED BY: DESCRIPTION NO. ALL RIGHTS RESERVED REVISIONS DATE: BY: CHK: DATE: DATE: DATE: 100 Valley Rd., Suite 202 , Mt. Arlington, N.J. 07856 973.398.1776 - suburbanconsulting.com CERTIFICATE OF AUTHORIZATION NO.: 24GA28037500 SOIL EROSION AND SEDIMENT CONTROL NOTES AND DETAILS PROJECT NUMBER: SCE-7733 SCALE: AS NOTED SHEET 9 OF 9 REVISION