aqua duck car wash hollow bee, lp
Transcription
aqua duck car wash hollow bee, lp
AQUA DUCK CAR WASH HOLLOW BEE, LP 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 PLANS PREPARED FOR PROJECT LOCATION: Lot 6A - 2130 SOUTH MARKET STREET MECHANICSBURG, PA 17055 Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 Project Location: AQUA DUCK CAR WASH HOLLOW BEE, LP Plans Prepared For COVER SHEET PLANS GENERATED BY: Jurisdiction: Upper Allen Township Cumberland County, PA Applicable Building Codes: PA UCC: 2009 IBC 2009 ICC - A117.1 2008 NFPA 70 (NEC) Description: This project involves the construction of a new car wash structure. The car was will consist of two automatic bays and an equipment room. Building Data: Occupancy Use: Car Wash REAR PERSPECTIVE VIEW NTS Occupancy Classification : Business Group B Construction Type: IIB - Non Combustible Building Area: Equipment Room = 844 sf Wash Bays = 1,757 sf Total Area = 2,601 sf No. PROJECT DATA Description NTS COVER SHEET GENERAL CONSTRUCTION NOTES FOUNDATION MAIN FLOOR EXTERIOR ELEVATIONS CROSS SECTION CROSS SECTION CROSS SECTION ENCLOSURE UNIT STANDARD DETAILS EQUIPMENT/MECHANICAL PLAN ELECTRICAL LIGHTING PLAN & PANEL LAYOUTS ELECTRICAL POWER PLAN PLUMBING PLAN PLUMBING DISTRIBUTION PLAN REVISIONS G-1.0 G-1.1 A-1.0 A-1.1 A-2.0 A-3.0 A-3.1 A-3.2 A-4.0 M-1.0 E-1.0 E-1.1 P-1.0 P-1.1 FRONT PERSPECTIVE VIEW Date INDEX OF DRAWINGS VICINITY MAP Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Fire Protection: Automatic Sprinklers not required Number of required exits: 1 required, 2 provided Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: G-1.0 01 10 00 - Summary 4.) Do not use calcium chloride admixtures. 1.) All work shall be performed in accordance with these drawings and any additional notes, specifications, manufacturer's instructions, codes, etc. referenced herein. 5.) Do not allow construction equipment on newly placed slabs for a min. of seven (7) days. 03 80 00 - Concrete Cutting & Boring 2.) These drawings are based primarily on the observation of the apparent construction of the structure and the qualified knowledge and experience of Yingst Engineers & Associates, Inc. Compliance with any specifications, except as expressly noted, legal, or code requirements, is specifically excluded from this project. No guarantee or warranty as to future life, performance, or need for future repairs of any kind is intended or implied. 1.) Sawcut joints must be completed within 4 hrs. of finishing and to a minimum depth of 1/4 the slab thickness (1/3 for fiber reinforced). Joints shall be caulked with a concrete compatible sealant and shall utilize backer rod. DIVISION 04: MASONRY 3.) Drawings should not be scaled. Contact Yingst Engineers & Associates, Inc. for clarification of any dimension in question. 4.) Details shown on these drawings are typical. While drawn for specific locations, the details are intended to establish the general types of details to be used throughout. In the event certain features of the construction are not fully shown on the drawings, their construction shall be of the same character as for similar conditions that are shown or noted. 1.) Provide mortar to meet the requirements of ASTM C270, type M below grade and type S for all other work. 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 DIVISION 01: GENERAL REQUIREMENTS 2.) Provide grout consisting of 1 part Type I Portland cement, 3 parts fine sand and 1 part course aggregate. Add enough potable water to produce flowable mix. A.) Fill masonry cores and voids between masonry solid with grout as indicated. 5.) The Contractor shall not make any changes without prior written authorization from Yingst Engineers & Associates, Inc. Any changes made without this authorization shall be immediately corrected at the Contractor's expense. 3.) Adequately protect mortar and grout from freezing for seven (7) days following placing. 4.) Do not use calcium chloride admixtures in mortar or grout. 6.) The Contractor shall obtain all permits and licenses required by the governing agencies unless otherwise arranged with the building owner. 01 30 00 - Administrative Requirements 04 20 00 - Unit Masonry 1.) Provide hollow (2 core) Grade N concrete blocks (CMU - concrete masonry units) conforming to ASTM C90. Use nominal sizes as indicated. 1.) Design Criteria used in structural analysis (unless otherwise noted): 2.) Tops of masonry shall be level and faces plumb. A.) Assumed soil bearing pressure = 2000 PSF (If site conditions indicate lesser value, notify Yingst Engineers & Associates, Inc. so that necessary structural modifications can be made.) B.) Design Roof Loads: a.) Live load = 30 PSF b.) Dead load = 10 PSF c.) Snow load = 30 PSF C.) Design Wind Loads: a.) Basic wind speed = 90 MPH b.) Wind exposure = Category "B" DIVISION 05: METALS 1.) All structural steel to be fabricated and erected in accordance with specifications of the American Institute of Steel Construction and furnished with shop coat paint. 2.) All steel hollow structural sections (HSS) shall conform to ASTM A500 Grade "B". 3.) Rolled steel plates and bars shall conform to ASTM A36. DIVISION 07: THERMAL AND MOISTURE PROTECTION 2.) All shop drawings prepared by subcontractors, suppliers, etc. shall be reviewed by Yingst Engineers & Associates, Inc. for conformance with the design concept and approved by the building owner prior to construction. 07 10 00 - Dampproofing and Waterproofing 1.) Install 6 mil poly-vapor barrier under all new interior concrete floor slabs. 01 50 00 - Temporary Facilities and Controls 07 60 00 - Flashing and Sheet Metal 1.) Contractor shall provide all necessary temporary bracing, shoring, and guying or other means to hold structural members and materials in place during construction, and to avoid excessive material stresses and damages. Temporary bracing and shoring shall remain in place until the structure is capable of supporting loads. 1.) All horizontal and vertical flashing shall be 0.019" min. aluminum or better, fabricated on site. 2.) If temporary relocation and/or removal of electrical, mechanical, and plumbing utilities is necessary to carry out the work, the Contractor shall perform this work himself or hire a qualified subcontractor to perform this work. Any interruptions of power shall be coordinated with, and approved by the owner. The Contractor is responsible for the reinstallation and reactivation of any utilities affected by this work. 01 60 00 - Product Requirements 1.) All materials to be installed shall be in compliance with the manufacturer's recommended specifications and installation procedures. 2.) The Contractor and/or subcontractor(s) shall not substitute materials without prior acceptance from Yingst Engineers & Associates, Inc. 07 70 00 - Roof and Wall Specialties and Accessories 1.) Gutters shall be pre-finished aluminum, 4" type K, 0.032" min. unless noted otherwise. Downspouts shall be pre-finished aluminum, 2" x 3" rectangular corrugated type K, 0.019" min. unless noted otherwise. Color to be selected by Building Owner. Install all accessories as required and seal all joints. 2.) Metal Drip Edge: Minimum .024" finished aluminum sheet, brake framed to provide three (3") inches roof deck flange, and 1-1/2" fascia flange with 3/8" drip at lower edge. Furnish in eight (8') feet minimum lengths. Color to match existing. 07 90 00 - Joint Protection 1.) Caulking materials to be Pacora, Kuhla, DAP or equal, first quality, gun grade, non-staining, elastic caulking compound, meeting Federal Specification TT-C598 Grade I. Applied without thinning. Caulk around all windows, doors, penetrations, different building materials, etc., to prevent water leakage and excessive air infiltration. 01 70 00 - Execution Requirements 1.) The contractor shall keep the building and site well organized and clean throughout the construction period. Provide daily cleanup and remove all scrap and debris from construction site. Reusable scrap materials shall be stored in a neatly maintained designated area. 2.) Contractor shall provide adequate temporary protection for materials and the building to prevent damages from the elements (weather) and work. 2.) Weather-stripping, head and jamb stripping, to be provided at all doors and windows. Door thresholds shall be aluminum or membrane set on full bed of caulking compound. Install continuous metal or membrane flashing around perimeter of all doors and windows including metal or membrane pan flashing. Integrate and seal into weather barrier per manufacturers specifications. All stripping shall be adjusted as necessary for proper operation of doors and windows and the entire installation shall present a continuous air barrier around the perimeter of all openings. Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 3.) Yingst Engineers & Associates, Inc. will not be responsible for the construction means, methods, techniques, sequences, jacking process or procedures, or related safety precautions. 1.) System to be a Fully Adhered System (FAS) or Mechanically Anchored System (MAS) consisting of 0.060 EPDM rubber membrane. FAS shall ensure that a compatible substrate is installed in order for system to adhere properly. Install per manufacturer's recommendations. Contractor to provide manufacturer's warranty on all installed work. Project Location: 07 50 00 - Membrane Roofing AQUA DUCK CAR WASH HOLLOW BEE, LP 2.) Yingst Engineers & Associates, Inc. assumes no liability to the building owner, any association, or others for acts or omissions of the contractor or any other persons performing work on the project, or for the failure of the Contractor to perform the work in accordance with the construction documents. 2.) If any drainage pipes (downspouts, footing drains, yard drains, etc.) are involved with the project, the Contractor shall have all final discharge locations for all new drainage piping approved by the local code official. Drainage water shall not discharge onto driveways or sidewalks, unless noted otherwise, to prevent ice problems in cold weather. Plans Prepared For 1.) All work shall comply with the latest governing editions of all applicable local, state, and federal codes, ordinances, and regulations. GENERAL CONSTRUCTION NOTES 01 40 00 - Quality Requirements DIVISION 08: OPENINGS DIVISION 03: CONCRETE 08 10 00 - Doors and Frames 1.) All concrete work shall conform to the latest requirements, including all revisions, of ACI 301 (Specifications for Structural Concrete), ACI 301 (Guide to Curing Concrete), and ACI 318 (Building Code Requirements for Structural Concrete). 1.) Door style, manufacturer and type to be selected by Contractor and approved by Building Owner. Install per manufacturers specifications. 03 20 00 - Concrete Reinforcing 2.) Doors shall meet or exceed the following requirements unless noted otherwise: 2.) All reinforcement, anchor bolts, pipe sleeves and other inserts shall be positively secured in place before concrete is placed. 03 30 00 - Cast-in-Place Concrete 1.) Use regular weight concrete (140 pcf) with Type I, IA or II Portland cement conforming to ASTM C150, aggregate conforming to ASTM C33, and potable water conforming to ACI 318-89, and in accordance with the following requirements: A.) Minimum 28-day strength: 3500 PSI, 4000 PSI if exposed to the exterior. B.) Entrained Air: 4-7% (all exposed concrete) C.) Maximum slump: 5 inches D.) Aggregate size: 1-1/2" maximum. Date 3.) Doors separating conditioned spaces and unconditioned spaces shall have a maximum U-Factor of 0.35 unless noted otherwise. DIVISION 31: EARTHWORK 1.) If required, remove any trees, shrubbery, and plant(s), which obstruct the work and dispose of within legal limits at an approved off-site location, or store for replanting as agreed to with the Building Owner. Description 4.) Door hardware by Schlage, Weiser, or equal and style to be selected by Building Owner. Install per manufacturers specifications. 2.) All footing excavations shall be inspected by the building official prior to the placing of any concrete. The building official shall be given adequate notice for the observation per local municipal requirements. 3.) Footing depths shall extend below local frost grade unless located in a frost protected area or otherwise thermally protected from frost heave. Where required, step footings to ratio of two (2) horizontal to one (1) vertical and pours shall be continuous. 4.) Soils used for back filling and compaction shall be granular, well graded, clean and free from debris and clay. Do not allow rocks or lumps larger than two (2) inches (nominal) to be filled against foundation walls. When compacting, place soil fill in six (6) inch deep layers and compact each layer using mechanical and/or manual devices to achieve a firm, stable base for successive layer(s) or final grading. 2.) Cure all concrete in accordance with accepted ACI Standards for the worst case weather conditions anticipated during the curing period. 5.) When applicable, the Contractor shall rough and finish grade the work site and restore areas damaged by construction work to original condition. All debris and excess earth material shall be disposed of off-site in accordance with all codes and ordinances. 3.) Adequately protect concrete from freezing for a minimum of seven days following placing. 6.) Final grade shall contain at least six (6) inches of topsoil where grass will be planted. No. A.) Detailing fabrication and placement of reinforcement shall be in accordance with ACI-315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Provide supports/ anchors as needed to maintain reinforcing placement during concrete pour. B.) The Contractor shall notify the building official as required by the municipality prior to each concrete pour. No concrete shall be placed until all reinforcing has been installed by the Contractor and inspected by the building official. C.) Min. concrete protective cover for reinforcing steel shall be as follows: a.) Footings = 3" b.) Beams = 2" c.) Slab = 1-1/2" d.) Walls = 1" at interior face: 3" at exterior face. A.) Exterior a.) U-Factor of 0.30 or less REVISIONS 1.) Reinforcing steel shall be intermediate grade new billet deformed bars conforming to ASTM A615 Grade 60. Welded wire fabric shall conform to ASTM A-185. Securely tie and anchor in position prior to placing concrete. Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: G-1.1 E D AA A-3.0 C B 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 F NO.5 CONT VERT FULL HGT REBAR W/ 90° HOOK INTO FOOTING (3" OUTSIDE RADIUS) SPACED EVERY 32" OC & COREFILLED (16" MIN REBAR SECTION OVERLAY) A 53' - 6" 10' - 6" 10' - 6" 10' - 6" 10' - 6" 10' - 6" 6" X 12" 6" 6" X 3" 18" x 8" CONT 3500 PSI CONC FOOTING W/ (2) NO.4 CONT REBARS INDICATES TYP POINT LOAD FROM ENCLOSURE ABOVE 3" F-2 TROUGH DRAIN ABOVE 3" 15' - 11" 14' - 11" TROUGH DRAIN ABOVE 3" TYP F-1 FOOTING DETAIL A 1" = 1'-0" TROUGH DRAIN ABOVE CC A-3.2 (3) NO.4 CONT REBARS EVENLY SPACED 3" 15' - 11" 14' - 11" 12" 1" (TYPE 2) R-BD INSUL MIN EA SIDE 3" EQ EQ 3" TROUGH DRAIN ABOVE TROUGH DRAIN ABOVE F-2 INDICATES TYP POINT LOAD FROM ENCLOSURE ABOVE 12" 6" Z B TYP F-2 FOOTING DETAIL 1" = 1'-0" Z Plans Prepared For BACKER ROD WITH SEALANT TROUGH DRAIN ABOVE FOUNDATION 6" CONT 12" x 18" 4000 PSI CONC STRIP FTG Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 PROVIDE (6) 5/8" ANCHOR BOLTS FOR BASE PLATE (6" MIN EMBED) Project Location: ISTOBAL ENCLOSURE COLUMN Y AQUA DUCK CAR WASH HOLLOW BEE, LP 32' - 10" Y 12" 32' - 10" F-2 8" REINF CMU WALL 8" REINF CMU WALL F-1 TYPE F-2 FOOTING Date F-1 6" UNEXCAVATED F-1 16' - 8" BACKER ROD W/ SEALANT 12" BB A-3.1 F-1 8" REINF CMU WALL REVISIONS 1" (TYPE 2) R-BD INSUL MIN ONE SIDE 1' - 5" 50' - 8" 2' - 4" 8" REINF CMU WALL Description 16' - 8" ISTOBAL ENCLOSURE COLUMN 1' - 5" No. 53' - 6" 1 A-1.0 FOUNDATION PLAN TYPE F-1 FOOTING 1/4" = 1'-0" C TYP COMBINATION FOOTING DETAIL 1" = 1'-0" Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: A-1.0 BILLS SAWCUT 34" MAX D BITUMINOUS EXPANSION JOINT MATERIAL INDUCED CRACK CHANGE D = DEPTH TYP EXPANSION JOINT DETAIL TYP CONTRACTION (CONTROL) JOINT DETAIL NTS IN WALL CHANGE MACHINE 717-533-3346 800-231-3346 www.yingstengineers.com 1/3 D MIN Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 OPTIONAL SEALANT COMPOUND OR MASONRY FILLER (DEPENDING ON FINISH FLOOR MATERIAL) 33" ± BACKER ROD W/ SEALANT NTS BILLS D C 16' - 0" A 53' - 6" 10' - 6" 10' - 6" 18' - 0" 10' - 6" 10' - 6" 10' - 6" 6" 6" 1' - 0" 6" 2' - 0" 1' - 6" 8' - 0" 28' - 6" 8' - 0" 1' - 6" COINS X 4' - 0" IN WALL VENDING MACHINE SLOPE X 2' - 4" B 34" MAX E 2' - 4" F 52" ± AA A-3.0 BILL RETURN SLOPE RAISED CONC PAD SLOPE SLOPE 6' - 5" B ADA SPECS - EQUIPMENT NTS 18' - 0" 8" REINF SPLIT CMU WALL Date 12' - 4" 2" FLOOR DRAIN 2" 5" THICK 4000 PSI CONC SLAB TYP W/ 6x6 W2.0 x W2.0 WWF REINF VERIFY SIZE & LOCATION WITH INSTALLER DURING BLOCK WORK 8" REINF SPLIT CMU WALL 6" MIN THICK 4000 PSI CAST-IN PLACE CONC TROUGH DRAIN 1' - 5" 50' - 8" COINS EQ EQ Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. 1' - 3" (3) NO.4 CONT REBARS EVENLY SPACED W/ NO. 4 TRANSV REBARS 48" OC 3" 4' - 0" TYP CHANGE EQ No. 8" REINF SPLIT CMU WALL SLOPE METAL GRATE 1' - 5" 3" EQ EQ 3" 53' - 6" 1 A-1.1 MAIN FLOOR PLAN Description SLOPE SLOPE BB A-3.1 SLOPE REVISIONS SLOPE 2' - 0" SLOPE 3' - 10" EQUIPMENT ROOM FLOOR DRAIN 6' - 5" 12' - 4" 6' - 5" 12' - 4" 42" STL DR 42" STL DR 3' - 10" 16' - 8" 8" REINF SPLIT CMU WALL AUTO PAY MACHINE 4' - 0" Z 12' - 4" 16' - 8" INDICATES TYP POINT LOAD FROM ISTOBAL ENCLOSURE 6" Z UNATTENDED AUTOMATIC ENTRY SYSTEM Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 CONC APRON SLOPE Project Location: TOUCH SCREEN Plans Prepared For CREDIT 48" MAX SLOPE 12' - 0" COINS 14' - 11" WASH BAY 1 SLOPE 10' x 10' OVHD DOOR 10' x 10' OVHD DOOR 15' - 11" CONC APRON TROUGH DRAIN BILLS MAIN FLOOR 6' - 0" 6" THICK 4000 PSI CONC SLAB TYP W/ 6x6-W2.9xW2.9 WWF REINF SLOPE 4' - 0" 4' - 0" 50" ± 1' - 6" SLOPE 8' - 0" 32' - 0" 28' - 6" VACUUM MACHINE 12' - 0" 8' - 0" CC A-3.2 8"± UNATTENDED AUTOMATIC ENTRY SYSTEM Y BILLS AQUA DUCK CAR WASH HOLLOW BEE, LP RAISED CONC PAD 6" THICK 4000 PSI CONC SLAB TYP W/ 6x6-W2.9xW2.9 WWF REINF 1' - 0" 2' - 0" 1' - 6" 60" ± COINS SLOPE 32' - 10" 30' - 6" Y 12' - 0" CONC APRON SLOPE 34" MAX TROUGH DRAIN 14' - 11" SLOPE 10' x 10' OVHD DOOR WASH BAY 2 EQ CONC APRON SLOPE 13' - 0" 15' - 11" SLOPE 10' x 10' OVHD DOOR EQ INDICATES TYP POINT LOAD FROM ISTOBAL ENCLOSURE A TYP TROUGH DRAIN DETAIL 1" = 1'-0" These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: 14-0268 08/26/14 1/4" = 1'-0" Drawn By: Checked By: DTH KBK, ZAH Sheet No: A-1.1 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 3 A-2.0 EAST ELEVATION 1/4" = 1'-0" Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 Project Location: AQUA DUCK CAR WASH HOLLOW BEE, LP Description Date 1/4" = 1'-0" No. A-2.0 WEST ELEVATION REVISIONS 2 1/4" = 1'-0" Plans Prepared For A-2.0 SOUTH ELEVATION EXTERIOR ELEVATIONS 1 Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. 4 A-2.0 NORTH ELEVATION These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. 1/4" = 1'-0" Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: A-2.0 BUILT-UP 2x4 STEEL PARAPET STUB WALL 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 METAL PAN FLASHING CAP OVER EPDM W/ 1" RETURN EA SIDE (SEALANT EA END TYP) METAL PAN FLASHING CAP OVER EPDM W/ 1" RETURN EA SIDE (SEALANT EA END TYP) 9" ± BUILT-UP 2x4 PARAPET STUB WALL 7" ± DECO CROWN MOLDING ALUM GUTTER 1/2"Ø ANCHOR BOLT (1 EA SIDE OF JOIST) MIN 4" EMBED FRIEZE BOARD 8"x8"x16" CONT BOND BEAM W/ (2) NO.4 CONT REBARS TYP 1/2"Ø ANCHOR BOLT (1 EA SIDE OF JOIST) MIN 4" EMBED FRIEZE BD A TYP PARAPET DETAIL 8"x8"x16" CONT BOND BEAM W/ (2) NO.4 CONT REBARS TYP 1" = 1'-0" B TYP GUTTER DETAIL 1" = 1'-0" SLOPE 1/8" PER FT MIN TOP OF CMU 1' - 10" TOP OF CMU B A-3.0 ISTOBAL MODULAR M22 STANDARD PRE-MFR WASHBAY ENCLOSURE UNIT 3' - 6" PURLIN VULCRAFT K-SERIES 12K1 OPEN WEB STEEL JOIST OR EQ TYP 5FT OC 2' - 2" 8" SPLIT FACE EXT CMU WALL (STD CMU TYP BELOW GRADE) W/ NO.5 CONT VERT REBAR 32" OC COREFILLED 15' - 8" 18' - 0" GLASS EQUIPMENT ROOM WASH BAY #2 MAIN FLOOR PLAN SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN MAIN FLOOR PLAN Description A A-1.0 B A-1.0 REVISIONS C A-1.0 6" THICK 4000 PSI CONC SLAB TYP W/ 6x6 W2.9 x W2.9 WWF REINF OVER 6 MIL POLY VAPOR BARRIER OVER 4" MIN COMPACTED 2B STONE 6" 5" THICK 4000 PSI CONC SLAB TYP W/ 6x6 W2.0 x W2.0 WWF REINF OVER 6 MIL POLY VAPOR BARRIER OVER 4" MIN COMPACTED 2B STONE Date 10' - 0" WASH BAY #1 No. 36" MIN 18' - 9" (Overall Height) COL Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 X Plans Prepared For Y CROSS SECTION Z Project Location: VULCRAFT TYPE "F" 1.5F20 OR EQ METAL DECKING (ARC SPOT WELD EA RIB 18" MAX SPACING APART) A A-3.0 AQUA DUCK CAR WASH HOLLOW BEE, LP EPDM RUBBER ROOF OVER TAPERED INSUL AS REQD A A-1.1 AA A-3.0 CROSS SECTION AA 3/8" = 1'-0" Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: A-3.0 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 METAL PAN FLASHING CAP OVER EPDM W/ 1" RETURN EA SIDE (SEALANT EA END TYP) BUILT-UP 2x4 STEEL PARAPET STUB WALL 9" ± DECO CROWN MOLDING SOLID BLOCKING TYP AS REQD 7" ± 1/2"Ø ANCHOR BOLT (1 EA SIDE OF JOIST) MIN 4" EMBED FRIEZE BOARD 8"x8"x16" CONT BOND BEAM W/ (2) NO.4 CONT REBARS TYP A TYP PARAPET SIDEWALL DETAIL 1" = 1'-0" A A-3.1 8" SPLIT FACE EXT CMU WALL (STD CMU TYP BELOW GRADE) W/ NO.5 CONT VERT REBAR 32" OC COREFILLED EQUIPMENT ROOM SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN SLOPE 1/8" PER FT MIN BB CROSS SECTION BB A-3.1 3/8" = 1'-0" Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 MAIN FLOOR PLAN No. SLOPE 1/8" PER FT MIN REVISIONS MAIN FLOOR PLAN Date 5" THICK 4000 PSI CONC SLAB TYP W/ 6x6 W2.0 x W2.0 WWF REINF OVER 6 MIL POLY VAPOR BARRIER OVER 4" MIN COMPACTED 2B STONE Description 18' - 0" VULCRAFT K-SERIES 12K1 OPEN WEB STEEL JOIST OR EQ TYP 5FT OC 36" MIN 18' - 9" (Overall Height) VULCRAFT TYPE "F" 1.5F20 OR EQ METAL DECKING (ARC SPOT WELD EA RID 18" MAX SPACING APART) Project Location: 5' - 0" TYP Plans Prepared For TOP OF CMU CROSS SECTION TOP OF CMU AQUA DUCK CAR WASH HOLLOW BEE, LP EPDM RUBBER ROOF OVER TAPERED INSUL AS REQD Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: A-3.1 E 10' - 6" D C 10' - 6" 10' - 6" 10' - 6" A 10' - 6" PURLIN 3' - 6" PURLIN B 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 F 1" (TYPE 2) R-BD INSUL TYP AT EXT Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 Project Location: AQUA DUCK CAR WASH HOLLOW BEE, LP 10' - 6" ISTOBAL MODULAR M22 STANDARD PRE-MFR WASHBAY ENCLOSURE UNIT Plans Prepared For 16' - 2" GLASS CROSS SECTION 2' - 2" COL ADJACENT CONC APRON MAIN FLOOR PLAN Description 3/8" = 1'-0" No. A-3.2 CROSS SECTION CC REVISIONS CC Date MAIN FLOOR PLAN Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: A-3.2 PERIMETER BEAM 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 TRUSS COLUMN ISOMETRIC VIEW TUBE STEEL PURLIN PLATE FRONT VIEW SADDLE BRACKET SIDE VIEW ISTOBAL - STANDARD TRUSS DETAILS COLUMN HEIGHT SUPPLEMENT (OPTIONAL) UNION PLATE UNION PLATE SIDE VIEW COLUMN SIDE Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 2.) Yingst Engineers & Associates, Inc. has reviewed the above noted manual. Based upon the information provided within the manual, the 5h/5H structure type is consistent with the requirements listed in the 2009 International Building Code design loads for snow (30psf) and wind (90mph). Project Location: 1.) Details shown are taken from the Istobal Car Wash Equipment Enclosure calculation manual prepared by Gomez Tercero & Asociados, and are intended to be used for informational purposes only. Refer to Istobal manual for further information. AQUA DUCK CAR WASH HOLLOW BEE, LP GENERAL ENCLOSURE UNIT NOTATIONS: NTS Plans Prepared For B ENCLOSURE UNIT STANDARD DETAILS PURLIN FRONT Date TRUSS STRAPS ELEVATION ISTOBAL - STANDARD COLUMN DETAILS NTS No. C ANCHOR PLATE Description PURLIN REVISIONS ANCHORING PLATE PERIMETER BEAM Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. TIE RODS These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: PLAN VIEW Drawn By: Checked By: 14-0268 08/26/14 DTH KBK, ZAH Sheet No: A ISTOBAL - STANDARD FRAME DETAILS NTS A-4.0 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 10 9 EQUIPMENT SCHEDULE 3 CONC APRON WASH BAY 2 CONC APRON 1 5 8 18 2 1 17 6 4 16 9 13 11 LABEL DESCRIPTION 1 AIRLIFT VINYL ROLLUP DOOR MOTOR AND CONTROL STATION 2 ISTOBAL FREESTANDING DRYER MOTOR CONTROL CENTER 3 ISTOBAL FREESTANDING DRYER 4 EACH 10 HP MOTORS 4 ISTOBAL TIRE SHINER 5 ISTOBAL DRYER TIMER SUSPENDED FROM ARCH 6 TSS 7 POSITION IN BAY SIGN 7 ISTOBAL M22 AUTOMATIC BAY 1 8 ISTOBAL TRACER AUTOMATIC WITH FLOOR MOUNT 9 ISTOBAL FREESTANDING ROCKER BLASTERS TRACER BAY 4 7 1 18 17 16 6 13 11 21 12 22 PNL-A 20 14 15 23 EQUIPMENT ROOM 29 ICS RFID READER AND TOWER 13 ICS AUTO SENTRY FLEX UNIT PAY STATION 14 ISTOBAL TRACER PUMP STAND 15 HYDROFLEX CHEMICAL INJECTOR SYSTEM - WALL MOUNT 16 ISTOBAL SIGNAL BOX FOR SIGN CONTROL 17 ISTOBAL DOOR CONTROL BOX 18 ISTOBAL COMMAND POST 19 ISTOBAL M22 AUTOMATIC PUMP STAND 20 POLY STORAGE TANKS FOR SPOT FREE WATER 21 PURWATER WALL MOUNT SPOT FREE RINSE PRODUCTION SYSTEM 30 22 ISTOBAL TIRE SHINE CONTROL STATION 31 28 23 3 HP AIR COMPRESSOR 27 24 ICS BACK ROOM SERVER WITH GFCI DEDICATED CIRCUIT 25 SECURITY CAMERA DVR, POWER BOX, AND MONITOR 26 UTILITY SINK 27 12 GALLON ELECTRIC WATER HEATER (MOUNTED ABOVE SINK) 28 LOCHNIVAR - 199,000 BTUH - DEICING BOILER AND PUMP CONTROLLERS 29 AQUA BIO WATER RECLAIM CONTROL CENTER, BLOWERS AND CYCLONES 30 GINSAN IN WALL VENDOR UNIT 31 GINSAN IN WALL CHANGER UNIT 32 GINSAN VACUUMS NOTE: 1.) All equipment shall be selected & approved by owner 2.) Owner to coordinate locations of all systems and conduits with contractor prior to pouring concrete. CONC FLOOR AS SPEC 32 32 EDGE INSULATION AS SPEC No. 24 26 12 15 20 = INDICATES AREA OF HEATED FLOOR 25 TSS ENTER WAIT SIGN PAD MOUNTED Date PNL-B 19 22 11 Description 2 1 TSS BACKLIGHTED MASTER MENU PAD MOUNTED REVISIONS 5 10 Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 CONC APRON WASH BAY 1 Project Location: CONC APRON AQUA DUCK CAR WASH HOLLOW BEE, LP 3 Plans Prepared For 10 EQUIPMENT/MECHANICAL PLAN 12 NOTE: REFER TO LAND DEVELOPMENT PLAN FOR LOCATION OF VACUUM ISLANDS TIE PIPING TO CONC REINFORCING 32 32 A 1 M-1.0 DEICING/FLOOR HEATING & EQUIPMENT PLAN 3/16" = 1'-0" RADIANT FLOOR HEAT SCHEMATIC NTS Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: Checked By: 14-0268 08/26/14 KBK SMY Sheet No: M-1.0 AWG 150 A 3 0 1 Dryer Bay #1 3 -- -- -- -- 5 -- -- -- -- 7 Tracer Pump 125 A 3 1 9 -- -- -- -- 11 -- -- -- -- 13 Reclaim System 60 A 3 8 15 -- -- -- -- 17 -- -- -- -- 19 M22 Bay Feed 40 A 3 8 21 -- -- -- -- 23 -- -- -- -- 25 PNL-B 150 A 3 0 27 -- -- -- -- 29 -- -- -- -- 31 Chem Injector 20 A 2 12 33 -- -- -- -- B C 14410 VA 14410... 14410 VA 14410 VA 14410... 14410 VA 11528 VA 4803... 11528 VA 4803 VA 11528... 4803 VA 4803 VA 3602... 4803 VA 3602 VA 4803... 3602 VA 3602 VA 1320 VA 3602 VA 1320 VA 3602... 10350 VA 1320 VA 0 VA 10518 VA 0 VA 7792 VA 624 VA 0 VA 728 VA 624 VA 728 VA AWG Poles Trip Circuit Description 0 3 -- -- -- -- 4 -- -- -- -- 6 8 3 60 A MM22 Pump 8 -- -- -- -- 10 -- -- -- -- 12 150 A Dryer Bay #2 CKT 2 8 3 40 A Tracer Bay Feed 14 -- -- -- -- 16 -- -- -- -- 18 12 3 20 A Air Comp 20 -- -- -- -- 22 -- -- -- -- 24 -- -- -- Space 26 -- -- -- Space 28 -- -- -- Space 30 12 2 20 A R/O Product Pump 32 -- -- -- -- 34 35 36 37 38 39 40 41 42 Total Load: 70181 VA 70350 VA 66272 VA Total Amps: 590 A 591 A 552 A Load Classification Connected Load Demand Factor Estimated Demand 4919 VA 100.00% 4919 VA Motor 171479 VA 100.00% 171479 VA Other 0 VA 0.00% 0 VA Total Est. Demand: 205034 VA Power 25204 VA 100.00% 25204 VA Total Conn.: 574 A 5280 VA 65.00% 3432 VA Lighting Receptacle CONC APRON CONC APRON CKT #10 PNL-B Total Conn. Load: 206882 VA PNL-B PNL-A EQUIPMENT ROOM CKT #6 PNL-B Total Est. Demand: 569 A Phases: 3 Mains Rating: 225 A Wires: 4 MCB Rating: 150 A A Poles AWG 1 VAC #1 25 A 1 10 3 VAC #3 25 A 1 10 5 VAC Lights 20 A 1 12 7 Bay Lights #1 20 A 1 12 9 Bay Lights #2 20 A 1 12 11 ICS COMP #1 20 A 1 12 13 ICS HT/AC #1 20 A 1 12 15 Vend/Changer 20 A 1 12 17 Security 20 A 1 12 19 Data Recpt 20 A 1 12 21 Softner/Filter 20 A 1 12 23 Dryer Ctrl #2 20 A 1 12 25 Dryer Ctrl #1 20 A 1 27 Site Lights 30 A 2 10 29 -- -- -- -- Dr Ctrl #2X 20 A 1 Dr Ctrl #2E 20 A 1 35 Dr Ctrl #1X 20 A 1 37 Dr Ctrl #1E 20 A 1 B C 2000 VA 2000... 2000 VA 2000 VA 960 VA 304 VA 708 VA 480 VA 304 VA 240 VA 600 VA 600 VA 1200 VA 1200 VA 960 VA 960 VA 720 VA 720 VA 960 VA 480 VA 480 VA 600 VA 500 VA 960 VA 480 VA 25 VA 1664 VA 960 VA AWG Poles Trip 10 1 25 A VAC #2 Circuit Description 2 10 1 25 A VAC #4 4 14 1 15 A Equip Rm Lights 6 12 1 20 A Menu Sign 8 12 1 20 A Exterior Lights 10 12 1 20 A ICS-CMP #2 12 12 1 20 A ICS HT/AC #2 14 12 1 20 A Floor Heat 16 12 1 20 A Tire Shiner #1 18 12 1 20 A Tire Shiner #2 20 12 1 20 A PNL GFCI 22 12 1 20 A Conv Recpt 24 14 1 15 A E-Lights 26 12 1 20 A Water Heater 28 1664 VA CKT 500 VA 32 500 VA 34 500 VA 36 500 VA 38 40 41 42 Lighting CKT #5 PNL-B 30 39 Load Classification CKT #5 PNL-B Total Load: 10389 VA 10548 VA Total Amps: 90 A 91 A LED NOTE: REFER TO LAND DEVELOPMENT PLAN FOR LOCATION OF VACUUM ISLANDS & POLE LIGHTS. LED Date Trip A.I.C. Rating: 10,000 1" CONDUIT Mounting: Surface 31 CONC APRON CKT #7 PNL-B Panel Totals Volts: 120/208 Wye Supply From: PNL-A 33 WASH BAY 1 CKT #26 PNL-B Location: Equipment Room Circuit Description CONC APRON CKT #9 PNL-B Branch Panel: PNL-B CKT WASH BAY 2 7792 VA 65 A Connected Load Demand Factor Estimated Demand 4919 VA 4919 VA 100.00% Other 0 VA 0.00% 0 VA Power 18540 VA 100.00% 18540 VA Receptacle 5280 VA 65.00% 3432 VA Plans Prepared For Poles ELECTRICAL LIGHTING PLAN & PANEL LAYOUTS Trip 1" CONDUIT Circuit Description Panel Totals Total Conn. Load: 28739 VA Total Est. Demand: 26891 VA Total Conn.: 80 A Total Est. Demand: 75 A GENERAL ELECTRICAL NOTATIONS: 1.) These electrical plans are diagrams only and are not to be scaled. 1 E-1.0 LIGHTING PLAN 3/16" = 1'-0" ELECTRICAL COMPONENT LEGEND SYMBOL 2.) Contractor shall verify all fixture locations in field prior to installation. 3.) All new electrical work shall be installed in accordance with 2008 National Electric Code and all other applicable codes and ordinances. Electrical contractor shall schedule, obtain, and pay for all required permits and inspections through the project superintendent. O DED O GFCI 3M 4.) All new electrical work shall be run concealed. Furnish and install all new lighting fixtures as specified. Provide and install all new wiring, panels, boxes. s PC 5.) The electrical contractor shall label all new and existing circuits in the panel. s DESCRIPTION 120V DEDICATED DUPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPT RECEPTACLE (GFCI) OCCUPANCY SENSOR - THREE-WAY LIGHT SWITCH PHOTO CELL LIGHT SWITCH 6.) All branch circuits shall be copper wiring unless noted otherwise. EXTERIOR BUILDING MOUNTED LIGHT W/ PHOTO CELL 7.) All exposed locations shall consist of type MC cable. CANOPY LIGHT FIXTURE - 38 WATT LED 8.) Circuits greater than 20 amps, wire shall be sized as indicated. All exposed locations shall consist of type MC cable or Romex installed in conduit. EMERGENCY LIGHTING CONNECTED TO 90 MINUTE BATTERY BACK-UP 9.) Wire in conduits shall be THHN/ THWN solid or stranded for all 15-30 amp circuits. All circuits above 30 amps shall be strand type THHN/ THWN only unless noted otherwise. 10.) Type UF cable or PVC conduit to be sized accordingly & shall be used in underground locations. EMERGENCY REMOTE HEAD CONNECTED TO 90 MINUTE BATTERY BACK-UP 2' x 8' LITHONIA FLUORESCENT LIGHT FIXTURE - 4-LAMP T-8 BULBS 11.) Grounding shall meet the 2008 NEC requirements. 12.) All electrical equipment to be installed shall be listed by a recognized testing agency such as UL. Description A CKT Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 MCB Rating: 600 A Project Location: Wires: 4 No. Mounting: Surface A.I.C. Rating: 10,000 Mains Rating: 600 A AQUA DUCK CAR WASH HOLLOW BEE, LP Volts: 120/208 Wye Phases: 3 REVISIONS Location: Equipment Room Supply From: Utility 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 Branch Panel: PNL-A Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: Drawn By: WIRE TAG W/ CIRCUIT NUMBER (RED INDICATES EMERGENCY CIRCUIT) Checked By: 14-0268 08/26/14 KBK SMY Sheet No: 13.) Owner to coordinate all conduit installation for controls and power to Istobal equipment prior to installing concrete. E-1.0 1 AIRLIFT VINYL ROLLUP DOOR MOTOR AND CONTROL STATION 2 ISTOBAL FREESTANDING DRYER MOTOR CONTROL CENTER 3 ISTOBAL FREESTANDING DRYER 4 EACH 10 HP MOTORS 4 ISTOBAL TIRE SHINER 5 ISTOBAL DRYER TIMER SUSPENDED FROM ARCH 6 TSS 7 POSITION IN BAY SIGN 7 ISTOBAL M22 AUTOMATIC BAY 1 8 ISTOBAL TRACER AUTOMATIC WITH FLOOR MOUNT 9 ISTOBAL FREESTANDING ROCKER BLASTERS TRACER BAY 12 ICS RFID READER AND TOWER 13 ICS AUTO SENTRY FLEX UNIT PAY STATION 14 ISTOBAL TRACER PUMP STAND 15 HYDROFLEX CHEMICAL INJECTOR SYSTEM - WALL MOUNT 16 ISTOBAL SIGNAL BOX FOR SIGN CONTROL 17 ISTOBAL DOOR CONTROL BOX CONC APRON WASH BAY 2 CONC APRON CKT #31 PNL-B CKT #12 PNL-B CKT #33 PNL-B CKT #23 PNL-B 18 ISTOBAL COMMAND POST 19 ISTOBAL M22 AUTOMATIC PUMP STAND 20 POLY STORAGE TANKS FOR SPOT FREE WATER 21 PURWATER WALL MOUNT SPOT FREE RINSE PRODUCTION SYSTEM 22 ISTOBAL TIRE SHINE CONTROL STATION 23 3 HP AIR COMPRESSOR 24 ICS BACK ROOM SERVER WITH GFCI DEDICATED CIRCUIT 25 SECURITY CAMERA DVR, POWER BOX, AND MONITOR 26 UTILITY SINK 27 12 GALLON ELECTRIC WATER HEATER (MOUNTED ABOVE SINK) 28 LOCHNIVAR - 199,000 BTUH - DEICING BOILER AND PUMP CONTROLLERS CKT #19,21,23 PNL-A CONC APRON AQUA BIO WATER RECLAIM CONTROL CENTER, BLOWERS AND CYCLONES 30 GINSAN IN WALL VENDOR UNIT 31 GINSAN IN WALL CHANGER UNIT 32 GINSAN VACUUMS CONC APRON CKT #37 PNL-B CKT #11 PNL-B CKT #21 PNL-B CKT #25 PNL-B CKT #18 PNL-B CKT #22 PNL-B CKT #13 PNL-B CKT #20 PNL-B PNL-B PNL-A CKT #32,34 PNL-A CKT #8,10,12 CKT #20,22,24 PNL-A PNL-A CKT #19 PNL-B NOTE: CKT #8 PNL-B WASH BAY 1 CKT #1,3,5 PNL-A CKT #35 PNL-B 29 CKT #14 PNL-B CKT #2,4,6 PNL-A EQUIPMENT ROOM 1.) All equipment shall be selected & approved by owner 2.) Owner to coordinate locations of all systems and conduits with contractor prior to pouring concrete. CKT #17 PNL-B CKT #24 PNL-B CKT #28 PNL-B CKT #16 PNL-B CKT #7,9,11 PNL-A CKT #31,33 PNL-A CKT #13,15,17 PNL-A CKT #15 PNL-B GENERAL ELECTRICAL NOTATIONS: 1.) These electrical plans are diagrams only and are not to be scaled. TIED IN SAME CONDUIT TIED IN SAME CONDUIT 4.) All new electrical work shall be run concealed. Furnish and install all new lighting fixtures as specified. Provide and install all new wiring, panels, boxes. 5.) The electrical contractor shall label all new and existing circuits in the panel. 1" CONDUIT 3.) All new electrical work shall be installed in accordance with 2008 National Electric Code and all other applicable codes and ordinances. Electrical contractor shall schedule, obtain, and pay for all required permits and inspections through the project superintendent. 1 1/2" CONDUIT 2.) Contractor shall verify all fixture locations in field prior to installation. 1 1/2" CONDUIT 1 1/2" CONDUIT ALL TANKS TO BE LOCATED IN ACCORDANCE WITH THE LAND DEVELOPMENT PLAN. REFER TO AQUA BIOS SYSTEM SPECIFICATIONS FOR FURTHER DETAILS. Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 TSS ENTER WAIT SIGN PAD MOUNTED Project Location: 11 AQUA DUCK CAR WASH HOLLOW BEE, LP TSS BACKLIGHTED MASTER MENU PAD MOUNTED CKT #14,16,18 PNL-A Plans Prepared For 10 717-533-3346 800-231-3346 www.yingstengineers.com DESCRIPTION ELECTRICAL POWER PLAN LABEL Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 EQUIPMENT SCHEDULE 6.) All branch circuits shall be copper wiring unless noted otherwise. 1" CONDUIT 7.) All exposed locations shall consist of type MC cable. 8.) Circuits greater than 20 amps, wire shall be sized as indicated. All exposed locations shall consist of type MC cable or Romex installed in conduit. 9.) Wire in conduits shall be THHN/ THWN solid or stranded for all 15-30 amp circuits. All circuits above 30 amps shall be strand type THHN/ THWN only unless noted otherwise. BIOLOGICAL TANK CLARIFIER TANK CLEAN WATER TANK CKT #2 PNL-B 1500 GALLON 3-COMPARTMENT SETTLEMENT TANK AERATION TANK CKT #4 PNL-B Date 10.) Type UF cable or PVC conduit to be sized accordingly & shall be used in underground locations. 11.) Grounding shall meet the 2008 NEC requirements. FROM UTILITY (ETR) CKT #1 PNL-B CKT #3 PNL-B (2 sets) AL 500 kcmil METER BASE SYMBOL O DED O GFCI 3M s PC s PNL-A PNL-B 600 A 120/208V 3Ø 150 A 120/208V 3Ø 1 E-1.1 POWER PLAN DESCRIPTION 120V DEDICATED DUPLEX RECEPTACLE GROUND FAULT CIRCUIT INTERRUPT RECEPTACLE (GFCI) OCCUPANCY SENSOR - THREE-WAY LIGHT SWITCH PHOTO CELL LIGHT SWITCH EXTERIOR BUILDING MOUNTED LIGHT W/ PHOTO CELL CANOPY LIGHT FIXTURE - 38 WATT LED 3/16" = 1'-0" EMERGENCY LIGHTING CONNECTED TO 90 MINUTE BATTERY BACK-UP GROUND 0 AWG - CU EMERGENCY REMOTE HEAD CONNECTED TO 90 MINUTE BATTERY BACK-UP 0 AWG - AL 4 AWG - CU BOND No. NOTE: REFER TO LAND DEVELOPMENT PLAN FOR LOCATION OF VACUUM ISLANDS Description ELECTRICAL COMPONENT LEGEND 13.) Owner to coordinate all conduit installation for controls and power to Istobal equipment prior to installing concrete. REVISIONS 12.) All electrical equipment to be installed shall be listed by a recognized testing agency such as UL. 2' x 8' LITHONIA FLUORESCENT LIGHT FIXTURE - 4-LAMP T-8 BULBS Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: 08/26/14 Drawn By: WIRE TAG W/ CIRCUIT NUMBER (RED INDICATES EMERGENCY CIRCUIT) 14-0268 Checked By: KBK SMY Sheet No: A ELECTRICAL PANEL DIAGRAM NTS E-1.1 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 3"ø 4"ø 3"ø 4"ø WASH BAY 2 4"ø 750 GALLON SEPARATION TANK 4"ø CYCL BLOWER 2"ø 2"ø PLUMBING SYSTEM SCHEMATIC 3"ø REPRESS TO EQUIP 2"ø ALL TANKS TO BE LOCATED IN ACCORDANCE WITH THE LAND DEVELOPMENT PLAN. REFER TO AQUA BIOS SYSTEM SPECIFCATIONS FOR FUTHER DETAILS. 4"ø NTS 4"ø BIOLOGICAL TANK CLARIFIER TANK CLEAN WATER TANK 1500 GALLON 3-COMPARTMENT SETTLEMENT TANK AERATION TANK 4"ø ø 3" ø 2" 2"ø 4"ø SANITARY/CYCLONE PLAN 1 P-1.0 3/16" = 1'-0" Description Date 4" TO SANITARY MAIN REVISIONS PIPING LEGEND SYMBOL SANITARY PIPE SLOPE REQUIREMENTS PIPE SIZE (Inches) MINIMUM SLOPE (Inch Per Foot) 2-1/2" or Less 1/4" 3" to 6" 8" or Larger DESCRIPTION No. A 3/4"ø 1 1/2"ø 3"ø 3" VTR CP 2"ø 3"ø Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 CONDENSATE DRAIN Plans Prepared For 3"ø 4"ø ø 3" FD 3"ø PLUMBING PLAN EQUIPMENT ROOM ø 3" FD 4"ø 750 GALLON SEPARATION TANK Project Location: WASH BAY 1 3"ø AQUA DUCK CAR WASH HOLLOW BEE, LP 3"ø Domestic Cold Water Piping GENERAL PLUMBING NOTATIONS: Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. Domestic Hot Water Piping 1.) These plumbing plans are intended to show the nature and conceptual layout of the domestic water supply & sanitary waste systems based on the estimated loads and general requirements. These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Schedule 40 Sanitary Waste Piping 2.) All new plumbing work shall be installed in accordance with the 2009 IPC. Plumbing contractor shall schedule, obtain, and pay for all required permits and inspections. Schedule 80 Cyclone Supply Piping 3.) Plumbing contractor shall furnish and install all soil, waste, and vent piping, fittings, valves, unions, sleeves, escutcheons, cleanouts, and similar items as required for installation of specified fixtures. All work shall be run concealed. Schedule 80 Cyclone Return Piping 4.) All water piping shall be plastic PEX (unless noted otherwise). Provide shutoff valves for all fixtures on both hot and cold water supplies. Schedule 80 Cyclone Air Piping 5.) Sanitary waste piping to be schedule 40 PVC connected to the existing sewer. Project No: Date: 1/8" 1/16" Drawn By: Checked By: 14-0268 08/26/14 KBK SMY Sheet No: P-1.0 DESCRIPTION 1 AIRLIFT VINYL ROLLUP DOOR MOTOR AND CONTROL STATION 2 ISTOBAL FREESTANDING DRYER MOTOR CONTROL CENTER 3 ISTOBAL FREESTANDING DRYER 4 EACH 10 HP MOTORS 4 ISTOBAL TIRE SHINER 5 ISTOBAL DRYER TIMER SUSPENDED FROM ARCH 6 TSS 7 POSITION IN BAY SIGN 7 ISTOBAL M22 AUTOMATIC BAY 1 8 ISTOBAL TRACER AUTOMATIC WITH FLOOR MOUNT 9 ISTOBAL FREESTANDING ROCKER BLASTERS TRACER BAY TSS BACKLIGHTED MASTER MENU PAD MOUNTED 11 TSS ENTER WAIT SIGN PAD MOUNTED 12 ICS RFID READER AND TOWER 13 ICS AUTO SENTRY FLEX UNIT PAY STATION 14 ISTOBAL TRACER PUMP STAND 15 HYDROFLEX CHEMICAL INJECTOR SYSTEM - WALL MOUNT 16 ISTOBAL SIGNAL BOX FOR SIGN CONTROL 17 ISTOBAL DOOR CONTROL BOX 18 ISTOBAL COMMAND POST 19 ISTOBAL M22 AUTOMATIC PUMP STAND 20 POLY STORAGE TANKS FOR SPOT FREE WATER 21 PURWATER WALL MOUNT SPOT FREE RINSE PRODUCTION SYSTEM 22 ISTOBAL TIRE SHINE CONTROL STATION 23 3 HP AIR COMPRESSOR 24 ICS BACK ROOM SERVER WITH GFCI DEDICATED CIRCUIT 25 SECURITY CAMERA DVR, POWER BOX, AND MONITOR 26 UTILITY SINK 27 12 GALLON ELECTRIC WATER HEATER (MOUNTED ABOVE SINK) 28 LOCHNIVAR - 199,000 BTUH - DEICING BOILER AND PUMP CONTROLLERS 29 AQUA BIO WATER RECLAIM CONTROL CENTER, BLOWERS AND CYCLONES 30 GINSAN IN WALL VENDOR UNIT 31 GINSAN IN WALL CHANGER UNIT 32 GINSAN VACUUMS CONC APRON WASH BAY 2 CONC APRON WASH BAY 1 CONC APRON 1 1 /2 " ø 10 1 1/2" WATER MAIN TO PA AMERICAN PIT CONC APRON NOTE: 1"ø 1/2"ø 1 1/2"ø 1 1/2"ø EQUIPMENT ROOM 1/2"ø 1.) All equipment shall be selected & approved by owner 2.) Owner to coordinate locations of all systems and conduits with contractor prior to pouring concrete. 3/4"ø 3/4"ø GAS METER ALL TANKS TO BE LOCATED IN ACCORDANCE WITH THE LAND DEVELOPMENT PLAN. REFER TO AQUA BIOS SYSTEM SPECIFCATIONS FOR FUTHER DETAILS. 1"ø GENERAL PLUMBING NOTATIONS: 1.) These plumbing plans are intended to show the nature and conceptual layout of the domestic water supply & sanitary waste systems based on the estimated loads and general requirements. 2.) All new plumbing work shall be installed in accordance with the 2009 IPC. Plumbing contractor shall schedule, obtain, and pay for all required permits and inspections. 3.) Plumbing contractor shall furnish and install all soil, waste, and vent piping, fittings, valves, unions, sleeves, escutcheons, cleanouts, and similar items as required for installation of specified fixtures. All work shall be run concealed. BIOLOGICAL TANK CLARIFIER TANK CLEAN WATER TANK AERATION TANK Lot 6A - 2130 S Market St Mechanicsburg, PA 17055 1 1/2"ø 1 1/2"ø Project Location: 1"ø 1/2"ø AQUA DUCK CAR WASH HOLLOW BEE, LP 1/2"ø 1 1/2"ø 1 1/2"ø 1 1/2"ø 1 1/2" PRESSURE REDUCER Plans Prepared For 1 1/2"ø 1/2"ø 3/4"ø 1/2"ø 1"ø 1/2"ø 1/2"ø 3/4"ø 1 1/2"ø 3/4"ø 3/4"ø 1 1/2"ø PLUMBING DISTRIBUTION PLAN PLUMBING FROM CONTROL SYSTEMS TO CARWASH UNITS 1"ø LABEL 717-533-3346 800-231-3346 www.yingstengineers.com Stephen M. Yingst, P.E., CBIE 421 W. Chocolate Ave., Hershey, PA 17033 EQUIPMENT SCHEDULE 1500 GALLON 3-COMPARTMENT SETTLEMENT TANK 4.) All water piping shall be plastic PEX (unless noted otherwise). Provide shutoff valves for all fixtures on both hot and cold water supplies. 1 PIPING LEGEND DISTRIBUTION LAYOUT 3/16" = 1'-0" Domestic Cold Water Piping Domestic Hot Water Piping Description DESCRIPTION REVISIONS Schedule 40 Sanitary Waste Piping No. SYMBOL P-1.1 Date 5.) Sanitary waste piping to be schedule 40 PVC connected to the existing sewer. Schedule 80 Cyclone Supply Piping Copyright © 2014, Yingst Engineers & Associates, Inc. All rights reserved. Schedule 80 Cyclone Return Piping Schedule 80 Cyclone Air Piping These drawings are instruments of service and remain the exclusive property of Yingst Engineers & Associates, Inc. The client shall be granted a non-exclusive licence to use the drawings solely for the project depicted on the drawings. The drawings may not be modified in any way and may not be used for subsequent buildings, additions, renovations, modifications or alterations without the express written consent of Yingst Engineers & Associates, Inc. Yingst Engineers & Associates, Inc. assumes no liability for any use of the drawings beyond the non-exclusive licence granted herein. Project No: Date: 14-0268 08/26/14 Drawn By: Checked By: KBK SMY Sheet No: P-1.1