DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017
Transcription
DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017
secondary framing Profiles STANDARD CEES AND ZEES Members can be manufactured to the nearest 1/8" in length from 6'-0" to 45'-0" (for Cees) and 7'-0" to 45'-0" (for Zees). For lengths other than listed, please inquire. B1 CEE ACTUAL SIZE GAUGE Web x B1 x B2 12 14 16 FINISH 10" x 21/2" x 21/2" 10" x 3" x 3" 10" x 31/2" x 31/2" 10" x 4" x 4" 12" x 21/2" x 21/2" 12" x 3" x 3" 12" x 31/2" x 31/2" Red Oxide Red Oxide Galvanized Red Oxide Galvanized Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide 4" x 21/2" x 21/2" 6" x 21/2" x 21/2" 6" x 21/2" x 21/2" 8" x 21/2" x 21/2" 8" x 21/2" x 21/2" 8" x 31/2" x 31/2" 9" x 3" x 3" 9" x 31/2" x 31/2" WEB B2 B1 ZEE WEB B2 (Symmetrical Flange) MANUFACTURED LOCATION Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Jacksonville / Woodland DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 LGSI ZEES Members can be manufactured to the nearest 1/8" in length from 7'-0" to 45'-0". For lengths under 7'-0" or over 45'-0", please inquire. ACTUAL SIZE GAUGE Web x B1 x B2 12 14 16 B1 5 7 9" x 2 /8" x 2 /8" LGSI ZEE WEB 9" x 31/8" x 33/8" 10" x 21/8" x 23/8" 10" x 25/8" x 27/8" 10" x 31/8" x 33/8" 10" x 35/8" x 37/8" B2 12" x 21/8" x 23/8" (Unsymmetrical Flange) 12" x 25/8" x 27/8" 12" x 31/8" x 33/8" 4" x 21/8" x 23/8" 6" x 21/8" x 23/8" 6" x 21/8" x 23/8" 8" x 21/8" x 23/8" 8" x 21/8" x 23/8" 8" x 31/8" x 33/8" PSF-4 FINISH Red Oxide Red Oxide Galvanized Red Oxide Galvanized Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide Red Oxide MANUFACTURED LOCATION Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Longmont / Jacksonville / Woodland Sellersburg / Jacksonville / Woodland © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing PATTERN #1 Cee and Zee Punch Patterns FOR STANDARD ZEES ONLY 7" CL 11/2" 1 /2" Bay Width 2" 5 4" 5 /8" x 3/4" Vertical Slots /8" Round Holes 11/2" 11/2" Punch pattern is similar on both ends. / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 5 8 11/4" Flange Bottom of Purlin 31/2" 11/2" PATTERN #2 / " x 3/4" Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) Standard punch patterns not available on 4" web members. 5 8 5 8 FOR STANDARD ZEES ONLY 1 1 /2" 1 1'-2" 11/4" Flange CL /2" Bay Width 1'-1/2" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 5 4" 2'-4" 5 /8" x 3/4" Vertical Slots /8" Round Holes 11/2" 11/2" Punch pattern is similar on both ends. Bottom of Purlin 11/2" 1'-1/2" 1'-2" PATTERN #3 / " x 3/4" Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 11/2" 5 8 5 8 / " Round Holes Shown (Sellersburg, IN only) 5 8 FOR STANDARD ZEES ONLY 1 11/2" Standard punch patterns not available on 4" web members. 3'-6" CL /2" Bay Width 1'-71/2" 1'-9" 5 4" 5 11/4" Flange /8" Round Holes 11/2" /8" x 3/4" Vertical Slots 11/2" Punch pattern is similar on both ends. Bottom of Purlin 1'-71/2" 1'-9" / " x 3/4" Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) Standard punch patterns not available on 4" web members. 5 8 11/2" 5 8 / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 5 8 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-9 secondary framing PATTERN #A 13/4" Cee and Zee Punch Patterns For 2'-31/2" or 4'-31/2" Laps For Standard and LGSI Zees 1' 1' 2" 2" 1' CL 1' 5 2" 2" /8" x 3/4" Vertical Slots 11/2" 11/2" Punch pattern is similar on both ends. If LGSI, Wide Flange Indicator 4" 2" 4" 4" 5 /8" Round Holes 2'-4" No flange punching for pattern #A. Standard punch patterns not available on 4" web members. PATTERN #B 13/4" For Standard and LGSI Zees 1' 1' 1' For 2'-31/2", 4'-31/2", or 6'-31/2" Laps 1' CL 1' 1' DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 2" 2" 2" 4" 2" 11/2" 11/2" Punch pattern is similar on both ends. If LGSI, Wide Flange Indicator 4" 4" 2" 2'-4" 33/4" 5 4" /8" Round Holes 5 /8" x 3/4" Vertical Slots Standard punch patterns not available on 4" web members. No flange punching for pattern #B. PATTERN #C 4" For Standard and LGSI Cees and Zees only No Lap 1 1 /4" 13/4" CL /2" Bay Width 1" 5 /8" Round Holes 11/2" If LGSI, Wide Flange Indicator 4" / " Round Holes Shown (Sellersburg, IN only) or 5/8" x 3/4" Horizontal Slots (Longmont, CO only) 5 8 11/4" Flange /2" Gap No Lap 1 11/2" Punch pattern is similar on both ends. Bottom of Purlin 11/4" 3" / " x 3/4" Vertical Slots Shown (Sellersburg, IN only) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 5 8 Standard punch patterns not available on 4" web members. PSF-10 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing PATTERN #D Cee and Zee Punch Patterns For 2'-31/2" or 4'-31/2" Laps For LGSI Zees only. 1' 13/4" 1' 2" 4" 1' 1' 2" 4" 2" 2" CL 4" 4" 5 11/2" /8" Round Holes 11/2" Punch pattern is similar on both ends. If LGSI, Wide Flange Indicator 4" 5 13/4" Flange /8" x 3/4" Vertical Slots Bottom of Purlin 21/4" 11/2" 11/2" 11/2" 11/2" 1'-13/4" 11/2" 11/2" 1' 11/2" 11/2" / " x / " Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 3 4 5 8 11/2" 1' / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) Standard punch patterns not available on 4" web members. 5 8 5 8 For LGSI Zees only. PATTERN #E 1' 1' 13/4" 2"2" 4" 1' 2" 2" For 2'-31/2", 4'-31/2", or 6'-31/2" Laps 2" 4" 1' 1' 2" 2" 2" CL 1' 4" 4" 4" 11/2" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Punch pattern is similar on both ends. If LGSI, Wide Flange Indicator 4" 11/2" /8" x 3/4" Vertical Slots 5 Bottom of Purlin /8" Round Holes 5 21/4" 11/2" 11/2" 11/2" 1 2 1 / " 11/2" 1' 1'-13/4" 13/4" from web (Sellersburg, IN) or (Jacksonville, FL) 11/4" from web (Longmont, CO only) PATTERN #F 11/2" 11/2" 11/2" 1' / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) Standard punch patterns not available on 4" web members. 5 8 For LGSI or Standard Zees only. 1' 1' 2" 4" 5 8 5 8 1 13/4" / " x 3/4" Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 2'-31/2" CL /2" Bay Width 1'-4" 2" 11/2" 5 If LGSI, Wide Flange Indicator 5 11/2" /8" Round Holes Punch pattern is similar on both ends. /8" x 3/4" Vertical Slots Bottom of Purlin 11/2" 1'-1 /4" 3 / " x 3/4" Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 11/2" 5 8 / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 5 8 13/4" from web (Sellersburg, IN) or (Jacksonville, FL) 11/4" from web (Longmont, CO only) Standard punch patterns not available on 4" web members. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-11 secondary framing PATTERN #G Cee and Zee Punch Patterns For Standard Zees only. 4'-31/2" 1 13/4" 2' 2' 2" 4" CL /2" Bay Width 2" 4" 11/2" If LGSI, Wide Flange Indicator 5 5 11/2" Punch pattern is similar on both ends. /8" Round Holes /8" x 3/4" Vertical Slots Bottom of Purlin / " x 3/4" Vertical Slots Shown (Sellersburg,IN) or (Jacksonville, FL) 5 8 / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 11/2" 11/2" / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 2'-13/4" 5 8 Standard punch patterns not available on 4" web members. 13/4" from web (Sellersburg, IN) or (Jacksonville, FL) 11/4" from web (Longmont, CO only) PATTERN #H For Standard Zees only. 6'-31/2" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 1 13/4" 8" 2'-4" 2'-4" CL 8" 2" 2" 4" /2" Bay Width 11/2" 5 If LGSI, Wide Flange Indicator 5 11/2" /8" Round Holes Punch pattern is similar on both ends. /8" x 3/4" Vertical Slots Bottom of Purlin / " x 3/4" Vertical Slots Shown (Sellersburg, IN) or (Jacksonville, FL) 5 8 / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 11/2" 11/2" 3'-13/4" 5 8 13/4" from web (Sellersburg, IN) or (Jacksonville, FL) 11/4" from web (Longmont, CO only) PATTERN #J / " Round Holes Shown (Sellersburg, IN) or (Jacksonville, FL) / " x 3/4" Horizontal Slots (Longmont, CO only) 5 8 Standard punch patterns not available on 4" web members. For LGSI or Standard Zees and Cees only. 13/4" 4" 5 Punch pattern is similar on both ends. /8" Round Holes Standard punch patterns not available on 4" web members. PSF-12 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Custom Punching Sellersburg, Indiana line only Custom punching can be done for Standard Cees, Zees, LGSI Zees, and Eave Struts. Web punching is available in 4" to 12" Cees, Zees, and Eave Struts. Punching is available only on center line of web for 4" member. Any combination of punching (1-11) can be punched together. Flange punching is available in 6" to 12" Cees, Zees, and Eave Struts only. Both holes or slots in 3, 4, 5, 6, 7, 10, and 11 must be punched together. 1 2 3 4 5 6 7 8 9 10 10 11 11 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 1" 1" C L 1" 1" 3" 3" 5 "X" "Z" 5 /8" x 3/4" Vertical Slots 3" spacing required between holes or slots in flanges. /8" Round Holes FLANGE PUNCHING Flange punching can be punched in either "X" or "Z". "X" must be 11/4", 13/4", or 2" from web. "Z" must be 21/4", 3", or 4" from web. Flange width must be 27/8", 3", 33/8", 31/2", 37/8", 4", or 5" for punching second holes or slots ("Z"). Zee LGSI Short Flange Web Cee or Eave Strut "X" "X" "Z" Flange PSF-14 C L © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net Flange secondary framing Custom Punching Longmont, Colorado line only Custom punching can be done for Standard Cees, Zees, and Eave Struts. Web punching is available in 4" to 12" Cees, Zees, and Eave Struts. Flange punching is available in 6" to 12" Cees, Zees, and Eave Struts only. Any combination of punching (1-12) can be punched together. 1 2 3 4 5 6 7 8 12 11 9 1" 1" C L 1" 1" 11/4" 10 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 5 5 5 21/4" 5 /8" x 3/4" Vertical Slots /8" x 3/4" Horizontal Slots /8" x 3/4" Vertical Slots /8" Round Holes FLANGE PUNCHING Flange punching can be punched in either "X", "Z", or Both dimensions from web. Zee Flange width must be 3" or 31/2" for punching second slots. Web Cee or Eave Strut 11/4" C L 21/4" 11/4" Flange Flange © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-15 secondary framing Custom Punching Jacksonville, Florida line only Custom punching can be done for Standard Cees, Zees, LGSI Zees, and Eave Struts. Any combination of punching with the exception of (8) can be punched together. Web punching is available in 4" to 12" Cees, Zees, and Eave Struts. Punching is available only on center line of web for 4" member. Both holes or slots in 3, 4, 5, 6, 7, 8, 14, and 15 must be punched together. Flange punching is available in 6" to 12" Cees, Zees, and Eave Struts only. All four holes or slots in 9, 10, and 11 must be punched together. 1 2 3 4 5 6 8 8 7 3" 9 9 4" 10 10 4" 11 11 4" 15 14 13 12 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 3" 3" 1" 1" C L 1" 1" 5 "X" "Z" 5 3" spacing required between holes or slots in flanges. /8" x 3/4" Vertical Slots /8" Round Holes FLANGE PUNCHING Flange punching can be punched in either "X" or "Z". "X" must be 11/4", 13/4", or 2" from web. "Z" must be 21/4", 3", or 4" from web. Zee LGSI Short Flange Flange width must be 27/8", 3", 33/8", 31/2", 37/8", 4", or 5" for punching second holes or slots ("Z"). Web Cee or Eave Strut "X" "X" "Z" Flange PSF-16 C L © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net Flange secondary framing Custom Punching Woodland, California line only *Punching Capabilities Custom punching can be done for Standard Cees, Zees, and LGSI Zees. Description /8" Hole /8" x 3/4" Vertical Slot 5 /8" x 3/4" Horizontal Slot 13 /16" Hole 13 /16" x 11/4" Vertical Slot 5 Web punching is available in 4" to 14" Cees and Zees. 5 11 Flange punching is available in 4" to 14" Cees and Zees only. /16" Hole 1 /16" Hole 13 /16" x 3/4" Vertical Slot 1 7 /16" Hole 1 2 3 4 5 9 6 "Z" "X" C L A** D** 7 8 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 B** C** *See Punching Capabilities *See Punching Capabilities "Q" "R" *See Punching Capabilities (above left). **Dimensions A, B, C, and D must be within web of purlin, please contact the Woodland Branch for more information (see page PGI-2-3). FLANGE PUNCHING Top Flange Flange punching can be punched in either "X", "Z", "Q", or "R". "X" must be 3/4" from web and no more than 3/4" from flange. "Z" must be 3/4" from web and no more than 3/4" from flange. "Q" must be 3/4" from web and no more than 3/4" from flange. "R" must be 3/4" from web and no more than 3/4" from flange. Top Flange Bottom Flange Flange "Z" "X" "Q" "R" "X" LGSI Short Flange C L Zee Web Cee or Eave Strut Flange Flange width must be 27/8", 3", 33/8", 31/2", 37/8", or 4" for punching second holes or slots ("Z")"Top Flange" or ("R")"Bottom Flange". © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net C L "Q" Bottom Flange PSF-17 secondary framing Standard Cee and Zee Information GENERAL INFORMATION Standard Secondary Framing (members with symmetrical flanges) are available in 4", 6", 8", 9", 10", and 12" web sizes and available in 2-1/2", 3", 3-1/2", 4", and 5" flange sizes. Metal Sales offers members in various gauges and finishes. In addition, members can be ordered to your desired length with standard or custom punching. For your specific loading requirements please reference Metal Sales' Technical Reference Product Manual. Symmetrical Flanges at Lapping Lapped Zees DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Cees PSF-18 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing SHORT LAP Standard Zee Lap Information FOR STANDARD ZEES ONLY TWO SPAN 7" 7" lapped section Zee Lapped Section 3 OR MORE SPANS 7" 7" 7" lapped section lapped section lapped section LONG LAP FOR STANDARD ZEES ONLY 2' - 4" TWO SPAN Zee 2' - 4" lapped section Lapped Section 3 OR MORE SPANS 2' - 4" lapped section MAX LAP 2' - 4" 2' - 4" lapped section lapped section DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 FOR STANDARD ZEES ONLY 3' - 6" Zee TWO SPAN Lapped Section 3' - 6" lapped section 3 OR MORE SPANS 3' - 6" lapped section SIMPLE SPAN (NO LAP) 3' - 6" lapped section 3' - 6" lapped section FOR STANDARD ZEES ONLY © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-19 secondary framing STANDARD SHORT LAP Standard Zee Lap Information (cont.) FOR STANDARD ZEES ONLY 7" Lap 11/2" 11/2" 4" 11/2" 3" For required lap condition use standard punch pattern #1. STANDARD LONG LAP FOR STANDARD ZEES ONLY 2'-4" Lap 11/2" 11/2" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 11" For required lap condition use standard punch pattern #2. STANDARD MAX LAP 11/2" 3" 1'-2" 11" FOR STANDARD ZEES ONLY 3'-6" Lap 11/2" 11/2" 11/2" 1'-6" For required lap condition use standard punch pattern #3. STANDARD (NO LAP) 3" 1'-9" 1'-6" FOR STANDARD ZEES ONLY 4" 1 1" /2" Gap 11/2" For required lap condition use standard punch pattern #C. PSF-20 3" © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Dimensions and Section Properties of Standard Zees B1 Fy = 55.0 KSI R = 0.125 In WEB B2 Effective Section Properties (Fully Braced) X-X Axis Full Section Properties SIZE Thickness Weight in plf Web x Flange GA A In2 Ix-x in4 rx in Iy-y in4 ry in Cw in6 J In4 Ae in2 Ixe in4 Sxe in3 Max K-ft Vay Kips 16 0.057 1.926 0.5661.5521.6651.0791.3802.5430.000610.3811.3580.6211.704 3.665 4" x 21/2" 14 0.070 2.365 0.6961.8911.6491.3341.3853.1350.001140.5151.7040.7932.176 5.367 16 0.057 2.314 0.6803.9102.3971.0791.2596.2980.000740.3893.4521.0662.927 2.865 6" x 21/2" 14 0.070 2.841 0.8364.7782.3911.3341.2637.7670.001370.5304.3271.3553.719 5.331 16 0.057 2.701 0.7947.6283.0991.0791.16512.0000.000860.3936.6111.5124.150 2.102 8" x 21/2" 14 0.070 3.317 0.9769.3363.0941.3341.16914.8060.001590.5388.5092.0155.529 3.907 12 0.105 4.976 1.46313.8763.079 2.039 1.18022.5000.005381.05513.5983.354 9.20412.437 8" x 3" 14 0.070 3.555 1.045610.4373.160 2.111 1.42022.3660.001700.552 9.116 2.106 5.780 3.907 12 0.105 5.333 1.56815.5133.145 3.219 1.43333.9200.005761.054114.4303.447 9.46112.437 14 0.070 3.793 1.11611.5373.2163.1391.67831.8930.001820.5569.6102.1625.933 3.907 8" x 3 /2" 1 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 12 0.105 5.690 1.67317.1493.201 4.780 1.69048.2840.006151.02214.8563.408 9.35412.437 9" x 3" 14 0.070 3.793 1.11613.7253.508 2.111 1.37629.1620.00182 0.554 11.8922.429 6.665 3.446 12 0.105 5.690 1.67320.4273.494 3.219 1.38744.2440.006151.06219.0324.05111.11811.728 9" x 3 /2" 14 0.070 4.031 1.18615.1213.571 3.139 1.62741.6620.001940.55912.3412.431 6.671 3.446 1 12 0.105 6.047 1.77822.5043.557 4.780 1.64063.0990.006541.03019.5824.01211.01211.728 10" x 21/2" 14 0.070 3.793 1.11615.8463.796 1.334 1.09424.3480.001820.54214.1042.625 7.203 3.083 12 0.105 5.690 1.67323.6073.756 2.039 1.10437.0310.006151.07023.1394.57112.54510.483 10" x 3" 14 0.070 4.031 1.18617.5713.850 2.111 1.33436.9460.001940.55614.8602.681 7.357 3.038 12 0.105 6.047 1.77826.1773.837 3.220 1.34656.0740.006541.06824.4314.69112.87410.483 10" x 31/2" 12 0.105 6.404 1.88328.7483.907 4.781 1.59380.1100.006921.03625.1234.65312.77010.483 10" x 4" 14 0.070 4.507 1.32621.0223.982 4.455 1.83372.4130.002170.56215.8842.686 7.372 3.083 12 0.105 6.761 1.98831.3183.969 6.775 1.846109.550.007311.10227.1434.99513.70810.483 12" x 2 /2" 1 12 0.105 6.404 1.88336.6854.413 2.039 1.04155.4690.006921.07935.9805.92916.273 8.646 12" x 3" 14 0.070 4.507 1.32627.0774.520 2.111 1.26255.5200.002170.55921.9093.188 8.750 2.546 12 0.105 6.761 1.98840.3994.508 3.220 1.27384.3130.007311.07737.8336.07716.678 8.646 12" x 3 /2" 1 12 0.105 7.118 2.09344.1134.591 4.781 1.511120.840.007691.04538.8606.04216.583 8.646 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-21 secondary framing Dimensions and Section Properties of Cees B1 Fy = 55.0 KSI R = 0.125 In WEB B2 Full Section Properties SIZE Thickness Weight in plf Web x Flange GA A In2 Ix-x in4 rx in Iy-y in4 ry in Cw in6 Effective Section Properties (Fully Braced) X-X Axis J In4 Ae in2 Ixe in4 Sxe in3 Max K-ft Vay Kips 16 0.057 1.926 0.5661.509 1.633 0.5150.9532.0581 0.000613 0.40641.3780.647 1.776 3.665 4" x 21/2" 14 0.070 2.365 0.6961.8351.6240.6300.3522.5640.0011360.5401.7140.8152.381 5.367 16 0.057 2.314 0.6803.8402.3760.5950.9354.5300.0007390.4153.5211.1113.049 2.865 6" x 21/2" 14 0.070 2.841 0.8364.6872.3680.7290.9345.6040.0013650.5554.3781.3953.829 5.331 16 0.057 2.701 0.7947.5323.0790.6520.9069.3280.000860.4186.8231.6034.400 2.102 8" x 21/2" 14 0.070 3.317 0.9769.2103.0720.8000.90610.2700.001590.5628.6262.0725.686 3.907 12 0.105 4.9756 1.46313.6493.054 1.196 0.90415.5610.0053781.10413.6493.412 9.36512.437 8" x 3" 14 0.070 3.555 1.04610.3113.1401.2431.09015.767 0.0017080.5839.3062.1866.000 3.907 12 0.105 5.3329 1.56915.2863.122 1.863 1.09023.9450.0057641.13414.8953.65510.03012.437 14 0.070 3.793 1.11611.4113.1981.8081.27322.735 0.0018220.5949.8802.2666.219 3.907 8" x 3 /2" 1 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 12 0.105 5.6899 1.67316.9223.179 2.712 1.27334.5690.0061501.09515.3713.616 9.92412.437 9" x 3" 14 0.070 3.7930 1.11613.5823.489 1.289 1.07520.3730.001820.58512.2562.562 7.031 3.446 12 0.105 5.68961.673420.1683.472 1.933 1.07530.8680.006151.14219.6494.28811.76911.728 9" x 3 /2" 14 0.070 4.0310 1.18614.9773.554 1.877 1.25829.3750.0019370.59612.8252.594 7.119 3.446 1 12 0.105 6.0466 1.77822.2453.537 2.818 1.25944.5610.0065361.10220.2484.24611.65411.728 10" x 21/2" 14 0.070 3.793 1.11615.6853.750 0.853 0.87416.7350.0018220.56614.4362.739 7.516 3.083 12 0.105 5.6896 1.67323.3163.733 1.277 0.87425.2560.0061501.11823.3164.66312.79810.483 10" x 3" 14 0.070 4.031 1.18617.4103.832 1.330 1.05925.7010.0019370.58715.3232.826 7.757 3.038 12 0.105 6.0466 1.77825.8873.815 1.995 1.05938.8750.0065361.14825.2214.95813.60610.483 10" x 31/2" 12 0.105 6.404 1.88328.4573.887 2.912 1.24356.1220.006921.10925.9584.91313.48510.483 10" x 4" 14 0.070 4.507 1.32620.8623.967 2.692 1.42551.0300.002170.60216.5862.879 7.901 3.083 12 0.105 6.7606 1.98831.0273.950 4.045 1.42677.3220.007311.16127.8005.20314.28010.483 12" x 2 /2" 1 12 0.105 6.404 1.88336.3314.392 1.340 0.84337.8370.006921.12736.3316.05516.618 8.646 12" x 3" 14 0.070 4.507 1.32626.8814.503 1.398 1.02738.6190.002170.58922.6163.358 9.217 2.546 12 0.105 6.7606 1.98840.0454.488 2.099 1.02758.2860.007311.15739.0256.40117.567 8.646 12" x 3 /2" 1 12 0.105 7.118 2.09343.759 4.572 3.072 1.211 84.1770.00769 1.118 40.0896.358 17.441 8.646 PSF-22 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Maximum Reaction for Zees and Cees Flange Flange Web Web Flange Web of C or Z Ga. Flange End Bearing (kips) Interior Bearing (kips) Length of Bearing Length of Bearing 2"3"4"5"6" 2"3" 4"5" 6" 16 0.650.7350.820.900.99 1.321.4521.6151.822.02 4" 14 1.09 1.211.331.451.572.0372.21 2.38 2.612.87 16 0.6 0.680.760.840.91 1.251.37 1.53 1.721.92 6" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 14 1.03 1.141.251.371.48 1.952.11 2.28 2.502.75 16 0.56 0.630.700.770.84 1.181.30 1.44 1.631.81 8" 14 0.96 1.071.181.281.89 2.872.02 2.18 2.392.63 12 2.56 2.772.973.183.38 4.454.71 4.97 5.235.49 10" 14 0.9 1.0 1.1 1.201.30 1.781.93 2.08 2.282.51 12 2.46 2.662.833.053.25 4.324.57 4.83 5.085.33 1. Above values have been calculated in accordance with 2001 AISI Specification, Eq. C3.4-1 (End Reaction) and Eq. C3.4-4 (Interior Reaction). PSF-28 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads GENERAL NOTES W - LB/FT W - LB/FT 3" 3" 6" 3" L L L 3" TWO SPAN SIMPLE SPAN W - LB/FT DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 6" 6" 3" L L L 3" 6" L THREE OR MORE SPANS 1. Tabulated values are allowable superimposed loads (PLF) on normal 1/2:12 to 4:12 roof pitches. Purlin weights have not been subtracted from them. They meet or exceed L/180 deflection criteria as indicated in the tables. 2. Weight of roofing material and other dead loads must be subtracted from tabulated values of purlins to determine net live load capabilities. 3. Allowable loads have been calculated in accordance with the 2001 edition of AISI Specifications. These values are valid only if the compression flange of the section is adequately supported laterally. 4. Consult with your engineer or architect for design applications such as very low or very high roof pitches (1/4:12, over 4:12), floating SSR, and for uplift (suction) criteria. Sag rods of angle bracing are usually required when members are not laterally supported by sheeting on the compression flange. 5. For continuous girts, wind load values can be obtained by multiplying tabulated values by 1.333. 6. End bearing capacity must be checked using actual load, bearing lengths, and the bearing chart. 7. For full member capacity, 1/2" diameter A-325 bolts are recommended for all lap bolts. 8. Web stiffeners can be provided by welding or bolting a clip plate to the support rafters and connecting the purlins through the web holes to the clip. 9. Tabulated values are based on a 6" bearing at interior supports. Reaction at end supports can be approximated by the following equations: Simple Span R = 0.50WL 2 Spans R = 0.375WL 3 or More Spans R = 0.40WL 10. Maximum live loads for deflection ratios other than L/180 can be calculated using the values tabulated as follows: For L/240: Max. LL (PLF) = (180/240) x (Tabulated Value). For L/360: Max. LL (PLF) = (180/360) x (Tabulated Value). © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-29 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES AND CEES (Symmetrical Flanges Only) Flange Flange Web Web Flange Section Flange Span in Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 16 Ga 14 Ga 16 Ga 8 213 272 9 168 215 10 136 174 14 Ga 149 11 113144102112 95 121 79 86 4" x 21/2" 12 81 103 62 68 Cee or 13 Zee 14 70895054 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 15 61774044 16 53683336 17 47602830 18 42542326 Span in Section Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 16 Ga 14 Ga 16 Ga 10 234 298 14 Ga 11 193 246 12 163 207 13 139 176 16 91 116 84 102 17 81 103 70 85 6" x 21/2" 14 119 152 Cee or 15 104132101124 Zee 18 72925972 20 59744352 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-30 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES AND CEES (Symmetrical Flanges Only) Flange Flange Web Web Flange Flange Simple Span (plf) Span in Section Feet Defl. (L/180) Controlling Stress Controlling 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 15 148 197 327 16 130 173 288 17 115 153255247 18 102 137227208 92 123 204 119 177 8" x 2 /2" 19 Cee or 20 83111184102 152 1 Zee DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 217510016772 88131 22 69911526377114 2363 84 13955 67180 24 5877128485988 25 5371 118435278 Section Span in Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 15 206 336 16 181 296 17 160 262 12 Ga 257 18 143234137217 8" x 3" 19 Cee or 20 Zee 21 22 128 210 116 184 116 189 100 158 105 172 86 136 96 156 75 119 23 8714366104 24 80 131 58 91 25 74 121 51 81 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-31 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES AND CEES (Symmetrical Flanges Only) Flange Flange Web Web Flange Section Flange Span in Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 15 211 333 16 185 292 17 164 259 18 146 231 8" x 3 /2" 19 Cee or 20 131 207 119 187 21 108 170 1 12 Ga DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Zee 162 22 9815598141 23 9014183123 24 8213073109 25 Span in Section Feet 76 120 65 96 Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 14 272 454 16 208 347 18 165 275 20 133 222 12 Ga 110 184 168 9" x 3" 22 Cee or 24 9315487129 Zee 26 7913268102 28 68 113 55 81 30 59994566 32 52873755 34 46773146 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-32 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES AND CEES (Symmetrical Flanges Only) Flange Flange Web Web Flange Flange Span in Section Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 14 272 449 12 Ga 16 208 344 18 165 272 20 133 220 9" x 3 /2" 22 Cee or 24 Zee 26 101 182 93 153 143 79 130 75 112 28 68 112 60 90 1 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 30 59984973 32 52864060 34 46763450 Span in Section Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 14 294 512 12 Ga 16 225 392 18 178 310 20 144 251 10" x 21/2" 22 Cee or 24 Zee 26 119 207 194 100 174 150 85 148 79 118 28 74 128 63 94 30 64 112 51 77 32 56984263 34 50873553 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-33 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES AND CEES (Symmetrical Flanges Only) Flange Flange Web Web Flange Section Flange Span in Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 12 Ga 14 300 525 16 230 402 18 182 318 20 147 257 10" x 3" 22 Cee or 24 122 213 102 179 166 26 87 152 130 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Zee 28 7513170104 30 65 114 57 85 32 57 101 47 70 34 51893958 Span in Section Feet Simple Span (plf) Stress Controlling Defl. (L/180) Controlling 12 Ga 12 Ga 14 664 16 509 18 402 20 325 12" x 21/2" 22 Cee or 24 Zee 26 269 193 183 28 166 146 30 145 119 32 127 98 34 113 82 226 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-34 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES AND CEES (Symmetrical Flanges Only) Flange Flange Web Web Flange Flange Span in Section Feet Simple Span (plf) Defl. (L/180) Controlling Stress Controlling 14 Ga 12 Ga 14 Ga 14 357 680 16 273 521 18 216 411 20 175 333 12" x 3" 22 Cee or 24 Zee 26 144 275 121 231 103 197 12 Ga DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 28 89 170 160 30 77 148 130 32 68 130 107 34 60 115 89 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-35 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 2'-4" Lap Web Long Lap Flange Long Lap - 2 Spans Long Lap - 3 Spans Span in Defl. (L/180) Stress Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 12 139 177155 198194 14 Z4" x 21/2" 16 96122 11314499121 70 90 8611066 81 18 5368 68864656 Long Lap - 2 Spans Long Lap - 3 Spans Span in Stress Stress Defl. (L/180) Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 14 153 202195 240 16 115 149145 189 Z6" x 21/2" 18 88 114112 146142 20 Span in Section Feet 70 91 8911684102 Long Lap - 2 Spans Stress Controlling, plf Defl. (L/180) Controlling, plf Long Lap - 3 Spans Stress Controlling, plf Defl. (L/180) Controlling, plf 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 16 139205370 174261436 18 110160286 140203360 20 90 128226 115163285 22 74 105184 95 134232 225 Z 24 6387 151 80 111 192 170 8" x 21/2" 25 5880 139 73 102 175 152 26 53 74128 68 94162 90 135 28 46 64109 58 80123 72 120 30 405594 50691184863 93 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-36 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 2'-4" Lap Web Long Lap Flange Long Lap - 2 Spans Long Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 165 292 211 370 20 133 231169 293 22 109 188138 238 Z8" x 3" 24 91 155115 196193 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 25 83 142106 180171 26 77 131 97165146 28 66 111 83 14181 121 30 5796 721216698 Long Lap - 2 Spans Section Long Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 169 289215 367 20 136 229173 290 22 112 186142 235 2493 154 118 194 Z8" x 31/2" 25 86 141108 178 26 79 129100 163 28 68110 85 139 134 30 58 9574 120 73 108 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-37 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 2'-4" Lap Web Long Lap Flange Long Lap - 2 Spans Long Lap - 3 Spans Span in Defl. (L/180) Stress Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 179 338226 429 20 146 268185 341 22 120 218153 277 Z9" x 3" 24 101 181128 229 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 2593 166 118 210 26 86 152109 193 28 74 130 94164159 30 64112 81 142 129 Long Lap - 2 Spans Section Long Lap - 3 Spans Span in Stress Stress Defl. (L/180) Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 179 335226 425 20 146 266185 337 22 120 216153 274 24 101 179128 227 Z9" x 31/2" 2593 164 118 208 26 86 151109 191 2874 129 94 163 3064 111 81 140 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 1996 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-38 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 2'-4" Lap Web Long Lap Flange Long Lap - 2 Spans Long Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 20 149 297186 377 22 124 242156 307 24 105 202132 255 25 97 185122 234 Z10" x 21/2" 2690 170 113 215 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 28 78145 98 184 30 68 126 86159151 32 59110 75 138 123 Long Lap - 2 Spans Section Long Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 20 152 300188 388 22 128 245158 318 24 107 207134 262 Z-10" x 3" 25 100 190125 240 26 92 175116 221 28 79 149101 189 30 69129 88162 32 61 113 77 142136 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 1996 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-39 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 2'-4" Lap Web Long Lap Flange Long Lap - 2 Spans Long Lap - 3 Spans Span in Stress Defl. (L/180) Defl. (L/180) Stress Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 12 Ga 12 Ga 20 358 456 22 296 376 24 248 315 25 Z1 12" x 2 /2" 26 229 290 211 268 28 182 230 30 158 200 32 138 175 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Long Lap - 2 Spans Long Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 20 155 365184 463 22 132 302158 384 24 113 254137 322 25 106 234127 296 Z12" x 3" 2698 216 119 273 28 86 186105 235 3076 161 93 204 3267 141 83 179 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 1996 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-40 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 3'-6" Lap Web Flange Max Lap Max Lap - 2 Spans Section Max Lap - 3 Spans Span in Stress Stress Defl. (L/180) Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 10 226 288229 292 12 160 204157 201198 14 119 152 115 147101 124 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Z16 4" x 21/2" 84107 87 11266 82 18 6280 69 884757 20 4861475755 713441 22 3844354145 582531 Max Lap - 2 Spans Section Max Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 16 Ga 14 Ga 14 185 250190 250 16 135 178152 193 18 103 135115 150140 Z20 6" x 21/2" 80104 95 12285105 22 6483 791006378 24 5368 66 834860 25 4862 61 774353 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 1996 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-41 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 3'-6" Lap Web Max Lap Flange Max Lap - 2 Spans Span in Section Feet Stress Controlling, plf Defl. (L/180) Controlling, plf Max Lap - 3 Spans Stress Controlling, plf Defl. (L/180) Controlling, plf 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 16 Ga 14 Ga 12 Ga 16 156240435 205286470 18 126183330 161225370 20 101145250 130180301 22 83 118 204106 147 246 226 Z 24 6997 166 88 123 208118176 8" x 21/2" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 25 6388 153 81 113 190103154 26 5981 139 74 103 176 92137 28 50 67118 64 8815159 72 110 30 43 59102 54 7512848 59 89 Max Lap - 2 Spans Max Lap - 3 Spans Span in Stress Stress Defl. (L/180) Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 189 339234 383 20 150 264188 309 22 121 211 155 252 Z8" x 3" 24 100 172128 213197 25 92 157117 196174 26 84 144107 181 103 154 28 72121 91 15482123 30 62 104 78 13267 99 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 1996 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-42 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 3'-6" Lap Web Max Lap Flange Max Lap - 2 Spans Max Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf Section 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 16 250 448300 480 18 194 337240 380 20 154 260193 300 22 124 210158 250 Z24 102 170130 212 8" x 31/2" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 25 94 155120 194190 26 86 142110 180168 28 74120 93 15290135 30 63 102 81 13073 110 Max Lap - 2 Spans Max Lap - 3 Spans Span in Stress Stress Defl. (L/180) Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 202 391261 449 20 163 305209 363 22 133 245171 299 Z9" x 3" 24 111 201142 250 25 102 183130 230229 26 94 167119 212203 28 80 142102 180162 30 69 122 88154131 32 60 105 77 133 72 108 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 1996 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-43 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 3'-6" Lap Web Flange Max Lap Max Lap - 2 Spans Max Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 203 387261 445 20 163 303209 359 22 133 243171 296 24 111 199142 248 Z1 9" x 3 /2" 25 102 181130 228 DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 26 94 166120 210 28 80 140102 178 30 69 120 88152144 Max Lap - 2 Spans Max Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Section Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 20 166 336 211 410 22 136 271176 337 24 115 223147 282 25 106 204135 258 Z10" x 21/2" 26 98 187125 237235 28 84 158107 201187 30 73 136 93172152 32 64118 81 149 124 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-44 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 3'-6" Lap Web Flange Max Lap Max Lap - 2 Spans Section Max Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 18 205 435260 520 20 168 345213 420 22 140 242176 350 Z 24 117 228150 290 10" x 3" DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 25 106 208138 265 26 100 190127 245 28 86 162108 205 Section Max Lap - 2 Spans Max Lap - 3 Spans 12 Ga 12 Ga Span in Stress Defl. (L/180) Defl. (L/180) Stress Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 20 401514 22 328419 24 273 348 25 Z12" x 21/2" 26 250 319 231 293 28 197 250 30 170 216 32 148 188 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-45 secondary framing Allowable Uniform Loads in Pounds per Linear Foot LOAD TABLES FOR STANDARD ZEES (Symmetrical Flanges Only) Flange 3'-6" Lap Web Flange Max Lap Max Lap - 2 Spans Section Max Lap - 3 Spans Span in Stress Defl. (L/180) Stress Defl. (L/180) Feet Controlling, plf Controlling, plf Controlling, plf Controlling, plf 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga 14 Ga 12 Ga DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 20 170 410200 520 22 143 335175 430 24 123 280150 350 Z 25 114 255140 325 12" x 3" 26 105 235131 300 2893 202 115 260 30 81 194100 220 Notes: 1. Tabulated values are allowable superimposed loads. Purlin and all other load weights have not been subtracted from them. 2. Allowable loads have been calculated in accordance with 2001 AISI Specifications. 3. Bearing must be checked using actual bearing length and loads. 4. Wind loads can be obtained by multiplying tabulated values by 1.33. 5. Tabulated values are valid only if the compression flange of the section is adequately supported laterally. PSF-46 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing LGSI Information The 2001 revision of the AISI specifications made it necessary for manufacturers of light gauge structural sections to make substantial revisions to their design properties, load table, and other published data. In an effort to answer the requirements mandated by this code revision, several manufacturers formed the Light Gauge Structural Institute in 1989. The Light Gauge Structural Institute is a nonprofit organization comprised of member companies who are in the business of manufacturing light gauge cold-formed sections. This manual is the result of an effort to develop uniform information about light gauge structural sections. Companies that are members of the Light Gauge Structural Institute conform to a set of bylaws and standards that ensure their compliance with the various policies set forth by the institute including, but not limited to, annual unannounced inspections that allow members to receive certification of compliance. The AISI code revisions created a need to investigate light gauge structural sections in a manner not previously addressed. As a part of this investigation, sections with unequal flanges were considered; and as a result of considerable design analysis and study, it became obvious that unequal flanges offered considerable advantages, particularly due to the number of applications that were lapped. Metal Sales also manufactures other light gauge structural sections that are not included in the scope of this manual. Metal Sales will provide information for these shapes unique to their operation. However, a requirement of the Light Gauge Structural Institute is that these shapes be designed in the same manner and using the same criteria applied to the sections in the Light Gauge Structural Steel Framing System Design Handbook. Section properties, section allowables, load tables and sample calculations are available in the "Light Gauge Structural Steel Framing System Design Handbook". Please refer to the latest edition of this handbook when inquiring about Light Gauge Structural Institute criteria. DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Light Gage Structural Steel Framing System Design Handbook Volume 1 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-47 secondary framing LGSI Zee Information LGSI Secondary Framing (members with unsymmetrical flanges) are available in 4", 6", 8", 9", 10", and 12" web sizes and available in 21/8" x 23/8", 25/8" x 27/8", 31/8" x 33/8", and 35/8" x 37/8" flange sizes. Metal Sales offers members in various gauges and finishes. In addition, members can be ordered to your desired length with standard or custom punching. For your specific loading requirements please reference Metal Sales' Technical Reference Product Manual. Bolt Bolt OR Purlin Clip Attached inverted purlins to beam with clip Attached purlins to beam with flange bolt DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Lapped Purlins Triangle punch in LGSI Purlin reflects where larger flange is located. PSF-48 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing LGSI Zee Lap Information (cont.) LONG LAP For Zees Only 2' - 31/2" TWO SPAN Zee 2' - 31/2" Lapped Section lapped section FOUR SPAN 2' - 31/2" 2' - 31/2" 2' - 31/2" lapped section lapped section lapped section 2' - 31/2" 2' - 31/2" 2' - 31/2" 2' - 31/2" 2' - 31/2" lapped section lapped section lapped section lapped section lapped section For required lap condition use standard punch pattern #A, #D, or #F. SIX SPAN MAX LAP For Zees Only 4' - 31/2" Zee TWO SPAN 4' - 31/2" lapped section FOUR SPAN 4' - 3 /2" 1 lapped section SIX SPAN 4' - 31/2" lapped section DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 4' - 31/2" 4' - 31/2" Lapped Section For required lap condition use standard punch pattern #A or #D. lapped section lapped section 4' - 31/2" 4' - 31/2" 4' - 31/2" 4' - 31/2" lapped section lapped section lapped section lapped section STANDARD LAP For Zees Only 2'-31/2" 4' - 31/2" Zee Zee Lapped Section For required lap condition use standard punch pattern #A or #D. FOUR SPAN 2'-31/2" 4' - 31/2" lapped section lapped section lapped section 4' - 31/2" 2'-31/2" 2'-31/2" 2'-31/2" lapped section lapped section lapped section lapped section 4' - 31/2" Lapped Section SIX SPAN 4' - 31/2" lapped section © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-49 secondary framing LGSI Zee Lap Information (cont.) SUPER LAP For Zees Only 6' - 31/2" Zee Lapped Section TWO SPAN For required lap condition use standard punch pattern #B, #E, or #H. 6' - 31/2" Lap Lapped Section EXTENDED LAP For Zees Only DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 4' - 31/2" 6' - 31/2" Zee Lapped Section Lapped Section For required lap condition use standard punch pattern #B or #E. FOUR SPAN 6' - 31/2" 4' - 31/2" 6' - 31/2" Lapped Section Lapped Section Lapped Section SIX SPAN 6' - 31/2" Lapped Section SIMPLE SPAN PSF-50 Zee 4' - 31/2" 4' - 31/2" 4' - 31/2" 6' - 31/2" Lapped Section Lapped Section Lapped Section Lapped Section For Zees Only © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net secondary framing LGSI Zee Lap Information (cont.) LGSI LONG LAP For Zees Only 2' - 31/2" Lap 1'-0" 2" 2" 1'-0" For required lap condition use standard punch pattern #A, #D, or #F. LGSI MAX LAP For Zees Only 4' - 31/2" Lap DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 2'-0" 2" 2" 2'-0" For required lap condition use standard punch pattern #A, #D, or #G. LGSI SUPER LAP For Zees Only 6' - 31/2" Lap 3'-0" 2" 2" 3'-0" For required lap condition use standard punch pattern #B, #E, or #H. © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net PSF-51 secondary framing LGSI Zee Lap Information (cont.) Use Eave Strut Punch Patterns: #S 3 C #S 3 D #S 4 #S 5 See Page PSF-13 for information. .5" 3" Holes punched at center point of member for bracing or sag rods. DISTRIBUTED BY: www.iMETAL.net PHONE: 267-983-1017 Vertical Slots or Holes for beam attachment. EAVE STRUT NOTES 1. Single Slope, Double Slope, or Universal Eave Struts are available, please specify. 2. Before ordering Eave Struts, you must subtract 1/2" from bay width. PSF-52 © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com iMetal.net - Phone: 267-983-1017 - www.iMetal.net Punch Pattern similar on both ends