URDC - SIBA

Transcription

URDC - SIBA
URDC
FUSES
Fuses for DC and Traction Applications
Classes:
aR / gR / gRL(gS)
Voltage ratings:
440V DC to 4200V DC
Current ratings:
6A to 1000A
Standards:
UIC 550
IEC 60269-4
IEC 60077-5
VDE 0636-40
SIBA DC Fuses are available for clip-mounted and bolt
design. The fuses are used for traction, battery and railway
power circuit applications.
Due to the variety of applications please contact SIBA fo
information regarding use at different voltage ratings,
class or L/R time constants
Features and Benefits
Designed for heavy duty applications
Shock and vibration tested to 30 g
Developed according to customers specifications
Tested with different time constants
Designed for long life under severe service conditions
210
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
Fuses for DC and Traction Applications
Article
Description
440VDC
Selection Guide
Technical Data
216
216 - 217
218
218 - 219
220
220 - 221
No blown fuse indication
222
222 - 223
No blown fuse indication
224
224 - 225
226
226 - 227
228
228 - 229
230
230 - 231
232
232 - 233
234
234 - 235
14mmx51mm
5012434
5012634
5012934
No blown fuse indication
With 2.5N Striker
No blown fuse indication
63mm mounting centers
22mmx58mm
5014034
5014234
5014534
5014634
No blown fuse indication
With 2.5N Striker
No blown fuse indication
No blown fuse indication
80mm mounting centers
PCB mounting
660VDC / 440VDC
27mmx60mm
5019006
5019106
5019206
No blown fuse indication
With 2.5N Striker
No blown fuse indication
80mm mounting centers
700VDC
14mmx51mm
5011806
5020106
5020206
80mm mounting centers
000 DIN 80
No blown fuse indication
With blown fuse indication
With fitting for microswitch
2029221
2029220
2025920
750VDC
NH1
With fitting for microswitch
2055604
1000VDC
10mmx38mm
5021506
5021606
5021706
PCB mounting
50.6mm mounting centers
No blown fuse indication
SQB -DC90
9030020
9030021
9035020
9035021
Bladed 156mm mounting centers
Threaded M10
No blown fuse indication
With fitting for microswitch
No blown fuse indication
With fitting for microswitch
SQB -DC91
9031020
9031021
9036020
9036021
Bladed 156mm mounting centers
Threaded M8
Phone 1-973-575-7422
Fax 1-973-575-5858
No blown fuse indication
With fitting for microswitch
No blown fuse indication
With fitting for microswitch
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
211
URDC
FUSES
Fuses for DC and Traction Applications
Article
Description
1000VDC
Selection Guide
Technical Data
236
236 - 237
238
238 - 239
240
240 - 241
SQB -DC92
9032020
9032021
9037020
9037021
Bladed 171mm mounting centers
Threaded M10
No blown fuse indication
With fitting for microswitch
No blown fuse indication
With fitting for microswitch
SQB -DC92-2(Double Body)
9037821
Threaded M10
With fitting for microswitch
SQB -DC93
9033020
9033021
9038020
9038021
Bladed 171mm mounting centers
Threaded M12
No blown fuse indication
With fitting for microswitch
No blown fuse indication
With fitting for microswitch
SQB -DC93-2(Double Body)
9038821
242
With fitting for microswitch
Threaded M12
NH4
9008310
No blown fuse indication
243
20mmx127mm
9008010
9008210
With blown fuse indication
With 2.5N Striker
244
244 - 245
246
246 - 247
248
248 - 249
250
250 - 251
252
252 - 253
254
254 - 255
256
256 - 257
258
258 - 259
260
260 -261
1200VDC
SQB-DC0
9022325
9022326
Bracket 172mm mounting centers
No blown fuse indication
With fitting for microswitch
Bracket 142mm mounting centers
No blown fuse indication
With fitting for microswitch
SQB-DC2
9020325
9020326
SQB-DC2-2(Double Body)
9021325
9021326
Bracket 142mm mounting centers
No blown fuse indication
With fitting for microswitch
1500VDC
20mmx127mm
9008110
9008610
No blown fuse indication
With 2.5N Striker
20mmx190mm
9009010
9009110
No blown fuse indication
With 2.5N Striker
36mmx190mm
No blown fuse indication
With 2.5N Striker
9009410
9009510
2000VDC
SQB-DC0
9022225
9022226
Bracket 194mm mounting centers
No blown fuse indication
With fitting for microswitch
Bracket 194mm mounting centers
No blown fuse indication
With fitting for microswitch
SQB-DC2
9020225
9020226
212
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
Fuses for DC and Traction Applications
Article
Description
2400VDC
Selection Guide
Technical Data
262
262 - 263
264
264 & 265
265
265 - 266
SQB-DC0
9022125
9022126
Bracket 246mm mounting centers
No blown fuse indication
With fitting for microswitch
Bracket 244mm mounting centers
No blown fuse indication
With fitting for microswitch
SQB-DC2
9020125
9020126
SQB-DC2-2(Double Body)
9021125
9021126
Bracket 244mm mounting centers
No blown fuse indication
With fitting for microswitch
4000VDC
40mmx254mm
No blown fuse indication
9010010
267
4200VDC
SQB-DC0
9022025
9022026
Bracket 416mm mounting centers
No blown fuse indication
With fitting for microswitch
Bracket 416mm mounting centers
No blown fuse indication
With fitting for microswitch
268
268 - 269
270
270 & 272
271
271 - 272
274
274 - 275
276
276 - 277
SQB-DC2
9020025
9020026
SQB -DC92-2(Double Body)
9021025
9021026
Bracket 416mm mounting centers
No blown fuse indication
With fitting for microswitch
1000VAC
NH3
No blown fuse indication
2040704
2000VAC
NH3
No blown fuse indication
2040404
Accessories for DC and Traction Application Fuses
Article
Description
Selection Guide
Technical Data
Microswitches - Standard Level
M-Microswitch
2800104
Standard Level
Single Change Over Circuit
278
GL-Microswitch
2800201
2800202
Standard Level
Single Change Over Circuit
278
B-Microswitch
2800311
2800312
2800320
2800321
2800322
Single Change Over Circuit
Standard Level
278 - 279
Double Change Over Circuit
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
213
URDC
FUSES
Accessories for DC and Traction Application Fuses
Microswitches - Low Level
M-Microswitch
2801104
Low Level
Single Change Over Circuit
278
GL-Microswitch
2800203
2800204
Low Level
Single Change Over Circuit
278
B-Microswitch
2800410
2800411
2800412
2800420
2800421
2800422
Low Level
9108001
5106305.1DC
5106305.1LDC
5106305.2DC
5106305.2LDC
20mmx127mm 1-Pole
10mmx38mm 1-Pole, 1000VDC
10mmx38mm 1-Pole, 1000VDC
10mmx38mm 2-Pole, 1000VDC
10mmx38mm 2-Pole, 1000VDC
Single Change Over Circuit
279 - 280
Double Change Over Circuit
Fuse Modules
280
w/ Neon Lamp Indicator
281
w/ Neon Lamp Indicator
Fuse Modules
5105805.1DC
5105805.1LDC
5105805.1SDC
5105805.2DC
5105805.2LDC
5106305.1
5106305.1L
5106305.2
5106305.2L
5106305.3
5106305.3L
5106305.4
5106305.4L
14mmx51mm 1-Pole
w/ Neon Lamp Indicator
w/ Microswitch
14mmx51mm 2-Pole
10mmx38mm 1-Pole, 750VAC/DC
10mmx38mm 2-Pole, 750VAC/DC
10mmx38mm 3-Pole, 750VAC/DC
10mmx38mm 4-Pole, 750VAC/DC
282
w/ Neon Lamp Indicator
w/ Neon Lamp Indicator
w/ Neon Lamp Indicator
283
w/ Neon Lamp Indicator
w/ Neon Lamp Indicator
Fuse Bases
2155601
2500301
2100301.26
2118901
2118908
2118911
9109001
9109401
9109601
214
NH1, 1-Pole
External wall for 21 556 01
Insulating Contact Cover
281
80mm mounting centers
284
20mmx190mm
36mmx190mm
36mmx250mm
285
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
1202103 p7 SIBA UR 175 516pp 8/22/13 3:32 PM Page 215
URDC
FUSES
Accessories for DC and Traction Application Fuses
Fuse Clips and Terminals
Article
Description
Selection Guide
Technical Data
Fuse Clips and Terminals
5806316
5806319
5806317
6301701
6101701.3
6100101.2
6301701
5805806
6100201.3
6300201
6100201.4
5806006
6100401.3
6300201
9109401.3
9109401.4
10mm diameter contacts - PCB Mounting
10mm diameter contacts - PCB Mounting
10mm diameter contacts - Screw Mounting
Clamping Plate for 50 063 01
Terminal Link for 50 063 01
14mm diameter contacts - Screw Mounting
Clamping Plate for 61 001 01.2
14mm diameter contacts - PCB Mounting
20mm & 22mm diameter contacts - Screw Mounting
Clamping Plate for 61 002 01.3
Terminal Link for 61 002 01.3
20mmx & 22mm diameter contacts - PCB Mounting
27mm diameter contact - Screw Mounting
Clamping Plate for 61 004 01.3
36mm diameter contact - Screw Mounting
Terminal Link for 91 094 01.3
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
286
287
288
289
e-mail: [email protected]
www.siba-fuses.us
215
URDC
FUSES
URDC
Rated Voltage
[Un]
440V DC
Rated Breaking Test
Class Standard(s)
Voltage
Capacity
30kA(L/R=30ms 440V DC
E180276
gRL
(gS)
UL 248-13
IEC 60269-4
VDE 0636 Part 4
Size 14x51mm
Rated
Current
In
[A]
10
12
16
20
25
30
32
35
40
Without
Indicator
UL
Article Number rec
5012434.10
9
5012434.12
9
5012434.16
9
9
5012434.20
5012434.25
9
5012434.30
9
5012434.32
9
5012434.35
9
5012434.40
9
With Striker
2.5N
Striker
UL
Article Number rec
5012634.10
9
5012634.12
9
5012634.16
9
5012634.20
9
5012634.25
9
5012634.30
9
5012634.32
9
5012634.35
9
5012634.40
9
0.03
Units per Package
10
Without
Indicator
63mm
Article Number
5012934.10
5012934.12
5012934.16
5012934.20
5012934.25
5012934.30
5012934.32
5012934.35
5012934.40
UL
rec
9
9
9
9
9
9
9
9
9
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 440VDC
[W]
1.9
2.3
2.8
3.0
3.2
3.8
4.0
4.2
4.4
[A2s]
8
12
25
46
100
190
250
370
420
[A2s]
70
105
210
400
850
1 600
2 100
3 150
3 600
*
L/R=30ms
A
B
A
5012434
C
B
E
F
Dimensions
[in /mm]
B
D
A
B
C
D
E
F
G
H
2.00 / 51
0.55 / 14
0.28 / 7
0.20 / 4.9
2.50 / 63.5
3.03 / 7
0.34 / 8.7
0.20 / 5.5
G
H
5012934
A
5012634
Accessories
Fuse Modules - DIN Rail Mounting w/Lockout Clip
5105805.1DC
1-Pole
5105805.1LDC 1-Pole w/neon lamp indicator
2-Pole
5105805.2DC
5105805.2LDC 2-Pole w/neon lamp indicator
Page
282
Fuse Clips
6100101.2
6301701
5805806
Page
Fuse Clips Screw mounting
Clamping plate for 6100101.2
Fuse Clips PCB mounting
287
750V/50A
E186970
216
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
440V DC
Rated Breaking Test
Voltage
Capacity
30kA(L/R=30ms 440V DC
E180276
Class Standard(s)
gRL
(gS)
UL 248-13
IEC 60269-4
VDE 0636 Part 4
Size 14x51mm
Coefficients for Heavy Duty Applications
a
130
A2
1.0
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
217
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
440VDC
Class Standard(s)
Capacity
Voltage
30kA(L/R=30ms) 440VDC
gRL
(gS)
E180276
UL 248-13
IEC 60269-4
VDE 0636 Part 4
Size 22x58mm
Rated
Current
In
[A]
25
30
32
35
40
50
63
80
100
Without
Indicator
UL
Article Number rec
5014034.25
9
5014034.30
9
5014034.32
9
5014034.35
9
5014034.40
9
5014034.50
9
5014034.63
9
5014034.80
9
5014034.100
9
Without
Without
With
Indicator
Indicator
2.5N
Striker
PCB
80mm
UL
UL
UL
Article Number rec Article Number rec Article Number rec
5014234.25
9 5014534.25
9 5014634.25
9
5014234.30
9 5014534.30
9 5014634.30
9
5014234.32
9 5014534.32
9 5014634.32
9
5014234.35
9 5014534.35
9 5014634.35
9
5014234.40
9 5014534.40
9 5014634.40
9
5014234.50
9 5014534.50
9 5014634.50
9
5014234.63
9 5014534.63
9 5014634.63
9
5014234.80
9 5014534.80
9 5014634.80
9
5014234.100
9 5014534.100
9 5014634.100
9
Weight [kg/1]
0.055
Units per Package
10
5014034
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 440VDC
[W]
3.6
4.6
4.8
5.0
5.2
5.4
6.8
7.5
7.7
[A2s]
100
190
250
370
420
870
1 300
2 500
4 600
[A2s]
800
1 500
2 000
2 900
3 300
6 800
10 200
19 500
35 800
*
L/R=30ms
5014234
22
22
58
4.9
58
7
5014534
5014634
Accessories
Fuse Modules - DIN Rail Mounting w/Lockout Clip
1-Pole
5106005.1
5106005.1L
1-Pole w/neon lamp indicator
1-Pole w/Microswitch
5106005.1S
2-Pole
5106005.2
5106005.2L
2-Pole w/neon lamp indicator
5106005.2S
2-Pole w/Microswitch
5106005.3
3-Pole
3-Pole w/neon lamp indicator
5106005.3L
51005.3S 3-Pole w/Microswitch
218
Phone 1-973-575-7422
Fax 1-973-575-5858
Page
283
Fuse Clips & Terminal Links
Fuse Clips Screw mounting
6100201.3
6300201
Clamping plate for 6100201.3
Terminal Link for 6100201.3
6100201.4
5806006
Fuse Clips PCB mounting
Page
288
750V/100A
E186970
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
440V DC
Rated Breaking Test
Capacity
Voltage
30kA(L/R=30ms) 440V DC
E180276
Class Standard(s)
gRL
(gS)
UL 248-13
IEC 60269-4
VDE 0636 Part 4
Size 22x58mm
Coefficients for Heavy Duty Applications
a
130
A2
1.0
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
219
URDC
FUSES
URDC
Rated Voltage
[Un]
660VDC/440VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
Un
gR
Company Standard
E180276
Size 27x60mm
Rated
Current
In
[A]
8
10
12
16
20
25
32
40
50
63
80
100
110
125
160
Without
Indicator
With
2.5N
Without
Indicator
80mm
UL
Article Number rec
9
5019206.8
5019206.10
9
9
5019206.12
9
5019206.16
9
5019206.20
9
5019206.25
9
5019206.32
9
5019206.40
9
5019206.50
9
5019206.63
9
5019206.80
5019206.100
9
9
5019206.110
5019206.125
5019206.160
Rated Voltage[Un]
UL
Striker
Article Number rec Article Number
5019006.8
9 5019106.8
5019006.10
9 5019106.10
9 5019106.12
5019006.12
9 5019106.16
5019006.16
9 5019106.20
5019006.20
9 5019106.25
5019006.25
9 5019106.32
5019006.32
9 5019106.40
5019006.40
9 5019106.50
5019006.50
9 5019106.63
5019006.63
9 5019106.80
5019006.80
9 5019106.100
5019006.100
9 5019106.110
5019006.110
5019106.125
5019006.125
5019106.160
5019006.160
a
Striker minimum operating Voltage 10V
Weight [kg/1]
0.09
0.11
0.10
Units per Package
10
a
[V]
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
660VDC
440VDC
440VDC
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@660VDC
[W]
2.0
2.2
2.7
3.1
3.5
3.9
4.6
6.6
7.5
8.9
10.9
13.5
14.2
16.0
19.0
[A2s]
4
8
12
32
62
130
250
420
620
1 200
2 100
3 500
4 600
7 900
11 800
[A2s]
20
40
60
160
310
650
1 250
2 100
3 100
6 000
10 500
17 500
23 000
29 600
44 900
*
L/R=10ms
5019006
5019106
5019206
Accessories
Fuse Clips & Terminal Links
6100401.3
Fuse Clips Screw mounting
6300201
Clamping plate for 6100401.3
220
Phone 1-973-575-7422
Fax 1-973-575-5858
Page
Page
28
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
660V DC/440V DC
Rated Breaking Test
Capacity
30kA
Voltage
Un
Class Standard(s)
gR
Company Standard
E180276
Size 27x60mm
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
221
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
700V DC
Capacity
50kA
Class Standard(s)
Voltage
700V DC
aR
UL 248-13
E180276
Size 14x51mm
Rated
Current
In
[A]
6
8
10
12
16
20
25
30
35
40
50
Without
Indicator
UL
Article Number rec
9
5011806.6
9
5011806.8
9
5011806.10
5011806.12
9
9
5011806.16
9
5011806.20
5011806.25
9
5011806.30
9
5011806.35
5011806.40
5011806.50
Weight [kg/1]
0.022
Units per Package
10
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 700VDC
[W]
1.3
1.7
2.6
3.1
4.7
6.0
7.6
9.8
10.3
11.2
12.6
[A2s]
2.0
2.9
3.9
6.5
8.0
12
20
32
72
103
128
[A2s]
12
17
25
41
52
70
130
190
430
620
770
* (L/R=1ms)
14
51
5011806
Accessories
Fuse Modules - DIN Rail Mounting w/Lockout Clip
1-Pole
5105805.1DC
5105805.1LDC 1-Pole w/neon lamp indicator
5105805.2DC
2-Pole
5105805.2LDC 2-Pole w/neon lamp indicator
Page
282
Fuse Clips
6100101.2
6301701
5805806
Page
Fuse Clips Screw mounting
Clamping plate for 6100101.2
Fuse Clips PCB mounting
28
750V/50A
E186970
222
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
700V DC
Capacity
50kA
Class Standard(s)
Voltage
700V DC
aR
UL 248-13
E180276
Size 14x51mm
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
E11806- _
Arc voltage
diagram
DC voltage reduction
for L/R
1200
100
1000
80
Reduction factor for
power loss
1,0
Ip > 6 x In
UL
VDC
0,8
L
R
Kw
800
60
0,6
600
40
0,4
400
20
0,2
0
0
200
200
400
600
800
UB
VDC
Phone 1-973-575-7422
Fax 1-973-575-5858
200
400
600
800
UB
VDC
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
0
0,2
0,4
0,6
0,8
1,0
IB
IN
e-mail: [email protected]
www.siba-fuses.us
223
URDC
FUSES
URDC
Rated Voltage
[Un]
700V DC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
700V DC
aR
UL 248-13
E180276
Size 14x51mm
Rated
Current
In
[A]
10
12
16
20
25
32
40
50
63
Without
Indicator
Without
Indicator
63mm
UL
UL
Article Number rec Article Number rec
9 5020206.10
9
5020106.10
5020106.12
9 5020206.12
9
9 5020206.16
9
5020106.16
9 5020206.20
9
5020106.20
5020106.25
9 5020206.25
9
9 5020206.32
9
5020106.32
9 5020206.40
9
5020106.40
9 5020206.50
9
5020106.50
9 5020206.63
9
5020106.63
Weight [kg / 1]
0.022
Units per Package
10
A
B
C
D
E
F
G
A
5020106
2.00 /
0.55 /
2.50 /
3.03 /
0.34 /
Pre-arcing
Total
I2 t
I2 t*
@ 700VDC
[W]
1.1
1.2
2.0
2.3
3.1
4.1
4.6
7.0
9.5
[A2s]
12
20
32
63
82
130
250
330
512
[A2s]
67
120
190
360
480
740
1 460
1 900
3 900
*L/R=1ms
A
Dimensions
[in /mm]
B
Power
Loss
B
51
14
E
F
63.5
77
8.7
G
H
5020206
Accessories
Fuse Modules - DIN Rail Mounting w/Lockout Clip
5105805.1DC
1-Pole
5105805.1LDC 1-Pole w/neon lamp indicator
2-Pole
5105805.2DC
5105805.2LDC 2-Pole w/neon lamp indicator
Page
282
Fuse Clips
6100101.2
6301701
5805806
Page
Fuse Clips Screw mounting
Clamping plate for 6100101.2
Fuse Clips PCB mounting
287
750V/50A
E186970
224
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
700V DC
Capacity
30kA
Class Standard(s)
Voltage
700V DC
aR
UL 248-13
E180276
Size 14x51mm
Coefficients for Heavy Duty Applications
a
150
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
E21006-60_0
Arc voltage
diagram
DC voltage reduction
for L/R
Reduction factor for
power loss
100
1200
1.0
Ip > 6 x In
UL
VDC
80
1000
0.8
L
R
Kw
800
60
0.6
600
40
0.4
400
20
0.2
200
0
200
400
600
800
UB
VDC
Phone 1-973-575-7422
Fax 1-973-575-5858
0
200
400
600
800
0
UB
V DC
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
0.2
0.4
0.6
0.8
1.0
IB
IN
e-mail: [email protected]
www.siba-fuses.us
225
URDC
FUSES
URDC
Rated Voltage
[Un]
700VDC
E180276
Size NH000 - DIN 80
Rated
Current
In
[A]
35
50
63
80
100
125
160
200
250
315
Without
Indicator
DIN 80
UL
Article Number rec
9
2029221.35
9
2029221.50
9
2029221.63
2029221.80
9
9
2029221.100
9
2029221.125
9
2029221.160
9
2029221.200
9
2029221.250
9
2029221.315
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
aR
700VDC
30kA
Fuse Links for Low Inductance
Applications
With Top
Indicator
DIN 80
UL
Article Number rec
9
2029220.35
9
2029220.50
9
2029220.63
2029220.80
9
9
2029220.100
9
2029220.125
2029220.160
9
9
2029220.200
9
2029220.250
9
2029220.315
Weight [kg/1]
0.17
Units per Package
3
With Top
Indicator
70mm
Article Number
2025920.35
2025920.50
2025920.63
2025920.80
2025920.100
2025920.125
2025920.160
2025920.200
2025920.250
2025920.315
UL 248-13
VDE 0636 Part 40
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 700VDC
[W]
14
17
20
23
26
30
35
40
45
51
[A2s]
26
104
140
330
930
1 400
1 950
3 740
5 580
12 300
[A2s]
135
530
690
1 650
4 300
6 400
8 000
16 000
22 900
46 000
* (L/R=1ms)
2029221 / 2029220
2025920
Accessories
Fuse Bases
2118901
2118908
2118911
226
Page
Fuse Base 1-Pole
Phone 1-973-575-7422
Fax 1-973-575-5858
284
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
E186970
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
700V DC
E180276
Size NH000 - DIN 80
DIN80
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
aR
700V DC
30kA
Fuse Links for Low Inductance
Applications
UL 248-13
VDE 0636 Part 40
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
227
URDC
FUSES
URDC
Rated Voltage
[Un]
750V DC
Rated Breaking Test
Capacity
50kA
Class Standard(s)
Voltage
700V DC
gR
Company Standard
Size NH1
Rated
Current
In
[A]
32
40
50
63
80
100
125
160
With Top
Indicator
Article Number
2055604.32
2055604.40
2055604.50
2055604.63
2055604.80
2055604.100
2055604.125
2055604.160
Weight [kg/1]
0.37
Units per Package
3
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 750VDC
[W]
5.9
7.1
8.6
10
12
15
19
23
[A2s]
100
180
290
410
740
1 300
2 500
3 700
[A2s]
800
1 400
2 200
3 200
5 700
10 000
19 000
29 000
* (L/R=1ms)
Indicator
2055604
Accessories
Fuse Base
2155601
228
Page
1-Pole,
Phone 1-973-575-7422
Fax 1-973-575-5858
281
Microswitch (Red Hammer)
2800202
Standard Level
Low Level
2800204
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
Page
2
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
700V DC
Rated Breaking Test
Voltage
700V DC
Capacity
50kA
Class Standard(s)
gR
Company Standard
Size NH1
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.3
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
229
URDC
FUSES
URDC
Rated Voltage
[Un]
1000VDC
Rated Breaking Test
Capacity
30kA(L/R=1ms)
Class Standard(s)
Voltage
1000VDC
gR
UL 248-13
E180276
Size 10x38mm
Rated
Current
In
[A]
4
6
8
10
12
16
20
Without
Indicator
PCB
UL
UL
Article Number rec Article Number rec
5021506.4
9 5021606.4
9
9 5021606.6
9
5021506.6
9 5021606.8
9
5021506.8
9 5021606.10
9
5021506.10
9 5021606.12
9
5021506.12
9 5021606.16
9
5021506.16
9 5021606.20
9
5021506.20
Weight [kg/1]
0.009
Units per Package
10
Without
Indicator
Without
Indicator
50.6mm
UL
Article Number rec
5021706.4
9
9
5021706.6
9
5021706.8
9
5021706.10
5021706.12
9
9
5021706.16
9
5021706.20
5021506
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1000VDC
[W]
0.5
0.7
1.1
1.5
1.6
2.1
2.5
[A2s]
3
5
7
10
20
30
52
[A2s]
25
40
55
77
155
230
395
* (L/R=10ms)
5021606
5021706
Accessories
Fuse Module -DIN Rail Mounting
5106304.DC
1-Pole w/neon lamp indicator
5106304.2DC
2-Pole
230
Phone 1-973-575-7422
Fax 1-973-575-5858
Page
28
Fuse Clips
5806316
5806319
58063 7
6101701.3
Page
Fuse Clips PCB mounting
Fuse Clips PCB mounting
Fuse Clips Screw Mounting
Terminal Link
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
286
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage Rated Breaking Test
Class Standard(s)
[Un]
Voltage
gR
UL 248-13
Capacity
1000V DC
30kA(L/R=1ms) 1000V DC
E180276
Size 10x38mm
Coefficients for Heavy Duty Applications
a
130
A2
0.9
B1
1.25
B2
0.5
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
231
URDC
FUSES
URDC
Rated Voltage
[Un]
900V DC
Size SQB-DC90
Rated
Current
In
[A]
50
63
80
100
125
160
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
30kA(L/R=30ms) 1000V DC
100kA(L/R=40ms) 900V DC
100kA(L/R=100ms 750V DC
With
With
Without
Microswitch
Indicator
Microswitch
Adapter
Adapter
Article Number
Article Number
Article Number
Article Number
9030021.50
9035020.50
9035021.50
9030020.50
9035020.63
9035021.63
9030020.63
9030021.63
9030020.80
9035020.80
9030021.80
9035021.80
9030020.100
9030021.100
9035020.100
9035021.100
9030020.125
9035021.125
9030021.125
9035020.125
9030020.160
9035020.160
9030021.160
9035021.160
Bladed Contacts
Threaded Contacts
Weight [kg/1]
0.8
0.7
Units per Package
1
Without
Indicator
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Power
Loss
[W]
11
13
16
19
24
31
Pre-arcing
I2 t
[A2s]
480
900
1 900
3 600
6 600
11 200
Total
I2 t*
@ 1000VDC
[A2s]
3 200
6 200
13 000
24 500
45 000
76 500
* (L/R=10ms)
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.5
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
232
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
900VDC
Size SQB-DC90
Rated Breaking Test
Capacity
Voltage
30kA(L/R=30ms) 1000VDC
100kA(L/R=40ms) 900VDC
100kA(L/R=100ms 750VDC
Class Standard(s)
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Dimensions
[in / mm
9030020
4.88 / 124
0.79 / 20
1.69 / 43
6.14 / 156
0.24 / 6
ŷ
ŷ
0.43 / 11
0.43 / 11
7.13 / 181
9030021
A
B
D
E
F
G
H
I
J
L
4.88 / 124
0.79 / 20
1.69 / 43
6.14 / 156
0.24 / 6
2.28 / 58
3.27 / 83
0.43 / 11
0.43 / 11
7.13 / 181
Accessories
9030020
B & M Microswitches
278 - 280
9030021
Dimensions
[in / mm
9035020
9035021
4.88 / 124
A
4.88 / 124
0.79 / 20
0.79 / 20
B
D
1.69 / 43
1.69 / 43
ŷ
2.28 / 58
G
ŷ
3.27 / 83
H
4.96 / 126
4.96 / 126
L
M8
M8
M
Thread Depth
0.39 / 10
Maximum Torque
22N•m
16.2lb•ft
9035021
9035020
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
233
URDC
FUSES
Rated Voltage
[Un]
900V DC
URDC
Size SQB-DC91
Rated
Current
In
[A]
160
200
250
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
30kA(L/R=30ms) 1000V DC
100kA(L/R=40ms) 900V DC
100kA(L/R=100ms 750V DC
With
With
Without
Microswitch
Microswitch
Indicator
Adapter
Adapter
Article Number
Article Number
Article Number
Article Number
9031020.160
9036021.160
9031021.160
9036020.160
9031021.200
9036020.200
9036021.200
9031020.200
9031021.250
9036021.350
9036020.250
9031020.250
Threaded Contacts
Bladed Contacts
Weight [kg/1]
1.1
1.2
Units per Package
1
Without
Indicator
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1000VDC
[W]
28
37
45
[A2s]
9 500
17 000
27 000
[A2s]
51 000
116 000
184 000
* (L/R=10ms)
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.5
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
234
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
900VDC
Size SQB-DC91
Rated Breaking Test
Capacity
Voltage
30kA(L/R=30ms) 1000VDC
100kA(L/R=40ms) 900VDC
100kA(L/R=100ms 750VDC
Class Standard(s)
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Dimensions
[in / mm
9031020
5.08 / 129
1.02 / 26
2.01 / 51
6.54 / 166
0.24 / 6
ŷ
ŷ
0.73 / 18.5
0.43 / 11
7.48 / 190
9031021
A
B
D
E
F
G
H
I
J
L
5.08 / 129
1.02 / 26
2.01 / 51
6.54 / 166
0.24 / 6
2.60 / 66
3.58 /91
0.73 / 18.5
0.43 / 11
7.48 / 190
Accessories
B & M Microswitches
278 - 280
9031020
9031021
Dimensions
[in / mm
9036020
9036021
5.08 / 129
A
5.08 / 129
0.94 / 22
0.94 / 22
B
2.01 / 51
D
2.01 / 51
ŷ
2.60 / 66
G
ŷ
H
3.58 /91
5.18 / 131.5
5.18 / 131.5
L
M10
M
M10
Thread Depth
0.43 / 11
Maximum Torque
39N•m
28.7lb•ft
9036020
Phone 1-973-575-7422
Fax 1-973-575-5858
9036021
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
235
URDC
FUSES
URDC
Rated Voltage
[Un]
900V DC
Size SQB-DC92
Rated
Current
In
[A]
250
315
350
400
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
30kA(L/R=30ms) 1000V DC
100kA(L/R=40ms) 900V DC
100kA(L/R=100ms 750V DC
Without
With
With
Microswitch
Microswitch
Indicator
Adapter
Adapter
Article Number
Article Number
Article Number
Article Number
9032020.250
9032021.250
9037020.250
9037021.250
9037020.315
9037021.315
9032020.315
9032021.315
9037020.350
9032021.350
9032020.350
9037021.350
9032020.400
9032021.400
9037021.400
9037020.400
Bladed Contacts
Threaded Contacts
Weight [kg/1]
1.36
1.26
Units per Package
1
Without
Indicator
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1000VDC
[W]
48
57
61
67
[A2s]
21 500
38 000
57 100
79 800
[A2s]
141 000
249 000
374 000
522 000
* (L/R=10ms)
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.5
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
236
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
900VDC
Size SQB-DC92
Rated Breaking Test
Capacity
Voltage
30kA(L/R=30ms) 1000VDC
100kA(L/R=40ms) 900VDC
100kA(L/R=100ms 750VDC
Class Standard(s)
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Dimensions
[in / mm
9032020
5.08 / 129
1.02 / 26
2.36 / 60
6.73 / 171
0.24 / 6
ŷ
ŷ
0.77 / 19.5
0.51 / 13
8.11 / 206
9032021
A
B
D
E
F
G
H
I
J
L
5.08 / 129
1.02 / 26
2.36 / 60
6.73 / 171
0.24 / 6
2.95 / 75
3.94 / 100
0.77 / 19.5
0.51 / 13
8.11 / 206
Accessories
B & M Microswitches
278 - 280
9032020
9032021
Dimensions
[in / mm
90 370 20
90 370 21
5.08 / 129
5.08 / 129
A
0.94 / 24
0.94 / 24
B
2.36 / 60
D
2.36 / 60
ŷ
2.95 / 75
G
ŷ
H
3.94 / 100
5.18 / 131.5
5.18 / 131.5
L
M10
M10
M
Thread Depth
0.43 / 11
Maximum Torque
39N•m
28.7lb•ft
9037020
Phone 1-973-575-7422
Fax 1-973-575-5858
9037021
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
237
URDC
FUSES
URDC
Rated Voltage
[Un]
900V DC
Size SQB-DC92-2
Rated
Current
In
[A]
500
630
700
800
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
30kA(L/R=30ms) 1000V DC
100kA(L/R=40ms) 900V DC
100kA(L/R=100ms 750V DC
With
Microswitch
Adapter
Article Number
9037821.500
9037821.630
9037821.700
9037821.800
Weight [kg/1]
2.59
Units per Package
1
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1000VDC
[W]
96
114
122
134
[A2s]
86 000
152 000
228 400
319 200
[A2s]
564 000
996 000
1 496 000
2 088 000
* (L/R=10ms)
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.5
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
238
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
900VDC
Size SQB-DC92-2
Rated Breaking Test
Capacity
Voltage
30kA(L/R=30ms) 1000VDC
100kA(L/R=40ms) 900VDC
100kA(L/R=100ms 750VDC
Class Standard(s)
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Dimensions
[ in / mm]
A
5.08 / 129
1.77 / 45
B
C
0.43 / 11
2.36 / 60
D
F
0.16 / 4
G
5.79 / 147
H
6.77 / 172
2.83 / 72
I
1.89 / 48
J
5.81 / 147.6
K
L
5.18 / 131.5
M
M10
Thread Depth
0.43 / 11
Maximum Torque
39N•m
28.7lb•ft
9037821
Accessories
B & M Microswitches
278 -280
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
239
URDC
FUSES
URDC
Rated Voltage
[Un]
900V DC
Size SQB-DC93
Rated
Current
In
[A]
450
500
550
630
700
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
30kA(L/R=30ms) 1000V DC
100kA(L/R=40ms) 900V DC
100kA(L/R=100ms 750V DC
Without
With
With
Indicator
Microswitch
Microswitch
Adapter
Adapter
Article Number
Article Number
Article Number
Article Number
9033020.450
9033021.450
9038020.450
9038021.450
9038021.500
9033020.500
9033021.500
9038020.500
9038021.550
9033021.550
9033020.550
9038020.550
9038021.630
9033020.630
9033021.630
9038020.630
9033020.700
9033021.700
9038020.700
9038021.700
Bladed Contacts
Threaded Contacts
Weight [kg/1]
1.96
2.06
Units per Package
1
Without
Indicator
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
(L/R=10ms)
[W]
75
86
97
112
127
[A2s]
106 000
129 000
153 000
180 000
240 000
[A2s]
691 000*
835 000*
1 357 000**
1 615 000**
2 150 000**
* @ 1000VDC
** @ 900VDC
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.5
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
240
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
900VDC
Size SQB-DC93
Rated Breaking Test
Capacity
Voltage
30kA(L/R=30ms) 1000VDC
100kA(L/R=40ms) 900VDC
100kA(L/R=100ms 750VDC
Class Standard(s)
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Dimensions
[in / mm
9033020
5.14 / 130.5
1.38 / 35
2.87 / 73
6.73 / 171
0.24 / 6
ŷ
ŷ
0.94 / 24
0.51 / 13
8.11 / 206
9033021
A
B
D
E
F
G
H
I
J
L
5.14 / 130.5
1.38 / 35
2.87 / 73
6.73 / 171
0.24 / 6
3.46 / 88
4.45 / 113
0.94 / 24
0.51 / 13
8.11 / 206
Accessories
B & M Microswitches
278 -280
9033021
9033020
Dimensions
[in / mm
90 380 20
90 380 21
A
5.14 / 130.5
5.14 / 130.5
1.10 / 28
1.10 / 28
B
D
2.87 / 73
2.87 / 73
ŷ
3.46 / 88
G
ŷ
H
4.45 / 113
5.18 / 131.5
5.18 / 131.5
L
M12
M
M12
Thread Depth
0.51 / 13
Maximum Torque
52N•m
38.3lb•ft
9038020
Phone 1-973-575-7422
Fax 1-973-575-5858
9038021
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
241
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
900VDC
Capacity
Voltage
30kA(L/R=30ms) 1000VDC
100kA(L/R=40ms) 900VDC
100kA(L/R=100ms 750VDC
Size SQB-DC93-2
Rated
Current
In
[A]
900
1000
1100
1250
1400
With
Microswitch
Adapter
Article Number
9038821.900
9038821.1000
9038821.1100
9038821.1250
9038821.1400
Weight [kg/1]
4.04
Units per Package
1
Class Standard(s)
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
(L/R=10ms)
[W]
150
172
194
224
254
[A2s]
424 000
516 000
612 000
720 000
960 000
[A2s]
2 764 000*
3 340 000*
5 428 000**
6 460 000**
8 600 000**
* @ 1000VDC
** @ 900VDC
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.5
Cf3
0.8
Accessories
B & M Microswitches
287 - 289
9038821
Dimensions
[ in / mm]
A
5.14 / 130.5
1.97 / 50
B
C
0.51 / 13
D
2.87 / 73
0.16 / 4
F
G
6.85 / 174
7.83 / 199
H
I
3.39 / 86
J
2.13 / 54
K
5.81 / 147.6
L
5.18 / 131.5
M12
M
Thread Depth
0.51 / 13
242
Virtual Pre-arcing time - [s]
Time-Current Characteristics
Maximum Torque
52N•m
38.3lb•ft
Phone 1-973-575-7422
Fax 1-973-575-5858
R.M.S. Prospective Current [A]
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
1000VDC
Rated Breaking Test
Capacity
40kA
Class Standard(s)
Voltage
1000VDC
gF
IEC 60 077-5
UIC 550
Size NH4
Without
Indicator
Article Number
9008310.500
9008310.550
9008310.630
9008310.700
9008310.800
Weight [kg/1]
3.9
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1000VDC
[W]
ŷ
ŷ
ŷ
ŷ
ŷ
[A2s]
250 000
330 000
480 000
695 000
1 030 000
[A2s]
750 000
980 000
1 400 000
2 000 000
2 900 000
* (L/R=15ms)
9008310
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Time-Current Characteristics
Virtual Pre-arcing time - [s]
Rated
Current
In
[A]
500
550
630
700
800
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
243
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
1000VDC
Class Standard(s)
Voltage aR/gR EN IEC 60269-4
1000VDC
DIN VDE-0636 Part 40
Capacity
100kA
Size 20x127mm
Rated
Current
In
Article Number
[A]
Article Number
Without Indicator
3.15 9008010.3.15
aR 9008210.3.15
With Striker
With Indicator
6
9008010.6
gR 9008210.6
9008010.8
8
gR 9008210.8
10
9008010.10
gR 9008210.10
12
9008010.12
gR 9008210.12
16
9008010.16
gR 9008210.16
20
9008010.20
gR 9008210.20
25
9008010.25
gR 9008210.25
9008010.32
32
gR 9008210.32
9008010.40
40
gR 9008210.40
50
9008010.50
gR 9008210.50
63
9008010.63
gR 9008210.63
Weight [kg/1]
0.1
Units per Package
12
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1000VDC
[W]
[A2s]
[A2s]
aR
4.1
2
13
gR
gR
gR
gR
gR
gR
gR
gR
gR
gR
gR
3.0
3.2
3.4
4.6
5.7
6.8
8.1
10.0
12.0
13.2
17.7
3
7
13
20
52
82
118
184
472
737
1 300
17
42
75
120
300
470
670
1 050
2 700
4 200
7 500
* (L/R=1ms)
9008010
9008210
Accessories
Fuse Modules
9108001
Fuse Base
9108001-B1
244
Page
1-Pole
280
1-Pole
Phone 1-973-575-7422
Fax 1-973-575-5858
Fuse Clips
6100201.3
6300201
6100201.4
5806006
Page
Fuse Clips Screw mounting
Clamping plate for 6100201.3
Terminal Link for 6100201.3
Fuse Clips PCB mounting
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
287 - 288
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
1000V DC
Capacity
100kA
Class Standard(s)
Voltage aR/gR EN IEC 60269-4
1000V DC
DIN VDE-0636 Part 40
Size 20x127mm
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Arc voltage
diagram
DC voltage reduction
for L/R
Reduction factor for
power loss
100
2500
1.0
Ip > 6 x In
UL
VDC
80
2000
0.8
L
R
Kw
1500
60
0.6
1000
40
0.4
500
20
0.2
0
0
0
400
800
1200
UB
VDC
Phone 1-973-575-7422
Fax 1-973-575-5858
0
800
900
1000
1100
UB
V DC
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
0
0.2
0.4
0.6
0.8
1.0
IB
IN
e-mail: [email protected]
www.siba-fuses.us
245
URDC
FUSES
Rated Voltage
[Un]
900VDC
URDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1200VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Rated
Current
In
[A]
25
32
40
50
63
80
100
125
160
200
215
Without
Indicator
With
Microswitch
Adapter
Article Number
Article Number
9022325.25
9022326.25
9022326.32
9022325.32
9022326.40
9022325.40
9022326.50
9022325.50
9022325.63
9022326.63
9022325.80
9022326.80
9022326.100
9022325.100
9022326.125
9022325.125
9022326.160
9022325.160
9022325.200
9022326.200
9022325.215
9022326.215
Weight [kg/1]
2
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1200VDC
[W]
15
19
23
28
34
41
50
58
80
88
ŷ
[A2s]
20
45
80
130
250
510
1 000
1 650
2 500
5 250
ŷ
[A2s]
190
410
730
1 150
2 250
4 600
8 900
14 800
16 500
35 000
ŷ
* (L/R=15ms)
M8 Contact Bolt
9022325
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9022326
Accessories
B & M Microswitches
278 - 280
246
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
Rated Voltage
[Un]
900V DC
URDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1200V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
247
URDC
FUSES
Rated Voltage
[Un]
900VDC
URDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1200VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2
Rated
Current
In
[A]
100
125
160
200
250
315
350
400
With
Microswitch
Adapter
Article Number
Article Number
9020325.100
9020326.100
9020325.125
9020326.125
9020325.160
9020326.160
9020325.200
9020326.200
9020326.250
9020325.250
9020326.315
9020325.315
9020325.350
9020326.350
9020326.400
9020325.400
Weight [kg/1]
3.5
Units per Package
1
Without
Indicator
9020325
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1200VDC
[W]
60
68
78
89
101
114
128
137
[A2s]
620
1 150
2 100
4 000
8 200
15 000
18 500
26 500
[A2s]
5 400
10 100
18 000
36 000
73 000
133 000
106 000
151 000
* (L/R=15ms)
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
Accessories
9020326
B & M Microswitches
278 - 280
248
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
Rated Voltage
[Un]
900V DC
URDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1200V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
249
URDC
FUSES
Rated Voltage
[Un]
900VDC
URDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1200VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2-2
Rated
Current
In
[A]
500
630
700
800
Without
Indicator
With
Microswitch
Adapter
Article Number
Article Number
9021325.500
9021326.500
9021325.630
9021326.630
9021326.700
9021325.700
9021326.800
9021325.800
Weight [kg/1]
7.0
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1200VDC
[W]
212
240
269
288
[A2s]
32 800
60 000
74 000
106 000
[A2s]
292 000
532 000
424 000
604 000
* (L/R=15ms)
Accessories
B & M Microswitches
278 - 280
9021325
9021326
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
250
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
Rated Voltage
[Un]
900V DC
URDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1200V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2-2
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
251
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
1500VDC
Class Standard(s)
Voltage aR/gR IEC 60 269-4
1500VDC
VDE 0636-4
DIN EN 60 369-4
Capacity
30kA
Size 20x127mm
Rated
Without
With
Indicator
Current
Indicator
In
Article Number
[A]
Article Number
2
9008110.2
aR
3.15 9008110.3.15
aR
9008110.5
5
6
9008110.6
9008110.8
8
9008110.10
10
9008110.12
12
9008110.16
16
9008110.20
20
9008110.25
25
Weight [kg/1]
0.1
Units per Package
12
With
2.5N
Striker
Article Number
gR
gR
gR
gR
gR
gR
gR
gR
9008610.5
9008610.6
9008610.8
9008610.10
9008610.12
9008610.16
9008610.20
9008610.25
gR
gR
gR
gR
gR
gR
gR
gR
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1500VDC
[W]
3.9
4.1
3.0
3.0
3.2
3.4
3.6
4.6
5.5
6.9
[A2s]
0.64
2.0
4.8
3.0
7.0
13
20
52
[A2s]
5
16
11
17
42
75
120
300
470
670
* (L/R=1ms)
82
118
9008110.2 - 3.15
9008110.5 -25 / 9008610.5 -25
Accessories
Fuse Modules
9108001
Fuse Base
9108001-B1
252
Page
1-Pole
280
1-Pole
Phone 1-973-575-7422
Fax 1-973-575-5858
Fuse Clips
6100201.3
6300201
6100201.4
5806006
Page
Fuse Clips Screw mounting
Clamping plate for 6100201.3
Terminal Link for 6100201.3
Fuse Clips PCB mounting
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
287 - 288
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
1500V DC
Capacity
30kA
Class Standard(s)
Voltage aR/gR IEC 60 269-4
1500V DC
VDE 0636-4
DIN EN 60 369-4
Size 20x127mm
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Time-Current Characteristics
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
T08110- _
Arc voltage
diagram
3000
DC voltage reduction
for L/R
100
Reduction factor for
power loss
1.0
Ip > 6 x In
UL
VDC
2500
80
0.8
L
R
Kw
2000
60
0.6
1500
40
0.4
1000
20
0.2
500
0
500
1000
UB
VDC
1500
Phone 1-973-575-7422
Fax 1-973-575-5858
0
1000
1500
UB
V DC
2000
0
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
0.2
0.4
0.6
0.8
1.0
IB
IN
e-mail: [email protected]
www.siba-fuses.us
253
URDC
FUSES
URDC
Rated Voltage
[Un]
1500VDC
Rated Breaking Test
Capacity
60kA
Class Standard(s)
Voltage
1500VDC
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Size 20x190mm
Rated
Current
In
[A]
6
8
10
12
16
20
25
32
Without
Indicator
With
2.5N
Striker
Article Number
Article Number
9009110.6
9009010.6
9009110.8
9009010.8
9009110.10
9009010.10
9009010.12
9009110.12
9009010.16
9009110.16
9009010.20
9009110.20
9009110.25
9009010.25
9009110.32
9009010.32
Weight [kg/1]
0.11
Units per Package
6
Power
Loss
Pre-arcing
Total
I2 t
I2 t
@ 1500VDC
[W]
3.1
4.1
4.4
4.7
6.2
7.6
8.1
9.7
[A2s]
7.4
13
30
53
90
150
240
600
[A2s]
44
80
180
320
550
900
1 400
3 600
9009010
9009110
Accessories
Fuse Base
9109001
254
Page
1-Pole
Phone 1-973-575-7422
Fax 1-973-575-5858
285
Fuse Clips
6100201.3
6300201
6300201.4
5806006
Page
Fuse Clips Screw mounting
Clamping plate for 6100201.3
Terminal Link for 6100201.3
Fuse Clips PCB mounting
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
287 - 288
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
1500V DC
Capacity
60kA
Class Standard(s)
Voltage
1500V DC
gR
IEC 60 077-5
UIC 550
VDE 0115 Part 460-5
Size 20x190mm
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
T09010-60 _0
Reduction
Reduction
factor for
factor
I 2t for I 2t Reduction
Reduction
Reduction
factor
factor
forfor
factor
powe
powe
for powe
Arc Voltage
Arc Voltage
Diagram
Diagram
100
3000
UL
VDC
1.0
80
2500
0.8
L
R
Kw
2000
60
0.6
1500
40
0.4
1000
20
0.2
0
500
500
1000
1500
2000
UB
VDC
Phone 1-973-575-7422
Fax 1-973-575-5858
0
500
1000 1500
UB
VDC
2000
0
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
0.2
0.4
0.6
0.8
1.0
IB
IN
e-mail: [email protected]
www.siba-fuses.us
255
URDC
FUSES
URDC
Rated Voltage
[Un]
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
1500VDC
gR
In compliance with
VDE 0636-1 & 4
Size 36x190mm
Rated
Current
In
[A]
20
25
32
40
50
63
80
100
Without
Indicator
With
2.5N
Striker
Article Number
Article Number
9009510.20
9009410.20
9009410.25
9009510.25
9009410.32
9009510.32
9009510.40
9009410.40
9009410.50
9009510.50
9009410.63
9009510.63
9009410.80
9009510.80
9009510.100
9009410.100
Weight [kg/1]
1
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 1500VDC
[W]
9
12
16
22
25
30
34
38
[A2s]
60
100
130
290
620
1 000
2 050
3 500
[A2s]
470
770
950
2 200
4 600
7 500
15 300
25 800
* (L/R=30ms)
9009410
9009510
Accessories
Fuse Modules
9109401
256
Page
1-Pole
Phone 1-973-575-7422
Fax 1-973-575-5858
285
Fuse Clips
9100401.3
9101401.4
Page
Fuse Clips Screw mounting
Terminal Link for 6100201.3
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
288
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Breaking Test
Rated Voltage
[Un]
1500V DC
Capacity
30kA
Class Standard(s)
Voltage
1500V DC
gR
In compliance with
VDE 0636-1 & 4
Size 36x190mm
Coefficients for Heavy Duty Applications
a
130
A2
0.6
B1
1.25
B2
0.6
Cf3
0.8
Time-Current Characteristics
104
103
s
40 A
8
10 2
A
100
80 A
32 A
25 A
5 6
x
63 A
50 A
20 A
Virtual Pre-arcing time - [s]
102
101
100
10 -1
8
6
5
4
3
2
10-2
10 1
2
3
4
2
3
4
5 6
8
10 3
2
3
4
5 6
8
10 4
A
2
3
4
5 6
8
105
R.M.S. Prospective Current [A]
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
257
URDC
FUSES
URDC
Rated Voltage
[Un]
1700VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2000VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Rated
Current
In
[A]
20
25
32
40
50
63
80
100
125
150
200
Without
Indicator
With
Microswitch
Adapter
Article Number
Article Number
9022226.20
9022225.20
9022226.25
9022225.25
9022225.32
9022226.32
9022226.40
9022225.40
9022226.50
9022225.50
9022225.63
9022226.63
9022226.80
9022225.80
9022225.100
9022226.100
9022225.125
9022226.125
9022225.150
9022226.150
9022225.200
9022226.200
Weight [kg/1]
2
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 2000VDC
[W]
25
28
37
43
57
60
73
75
80
85
125
[A2s]
11.5
20
32
46
82
184
328
1 000
1 660
2 950
5 300
[A2s]
96
170
270
390
680
1 600
2 700
8 400
13 800
24 500
30 000
* (L/R=15ms)
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
Accessories
9022225
258
Phone 1-973-575-7422
Fax 1-973-575-5858
M Microswitches
278 - 280
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
9022226
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
1700V DC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2000V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
259
URDC
FUSES
URDC
Rated Voltage
[Un]
1700VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2000VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2
Rated
Current
In
[A]
125
160
200
250
315
350
400
Without
Indicator
With
Microswitch
Adapter
Article Number
Article Number
9020225.125
9020226.125
9020225.160
9020226.160
9020226.200
9020225.200
9020226.250
9020225.250
9020225.315
9020226.315
9020225.350
9020226.350
9020226.400
9020225.400
Weight [kg/1]
2
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 2 000VDC
[W]
89
103
115
134
152
165
178
[A2s]
1 300
2 500
5 200
9 900
20 300
25 000
40 000
[A2s]
10 900
20 600
38 300
82 500
170 000
120 000
190 000
* (L/R=15ms)
Accessories
M Microswitches
278 - 280
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9020225
260
Phone 1-973-575-7422
Fax 1-973-575-5858
9020226
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
1700V DC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2000V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
261
URDC
FUSES
URDC
Rated Voltage
[Un]
1800VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2400VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Rated
Current
In
[A]
25
32
40
50
63
80
100
125
150
Without
Indicator
With
Microswitch
Adapter
Article Number
Article Number
9022125.25
9022126.25
9022125.32
9022126.32
9022125.40
9022126.40
9022126.50
9022125.50
9022125.63
9022126.63
9022126.80
9022125.80
9022125.100
9022126.100
9022125.125
9022126.125
9022125.150
9022126.150
Weight [kg/1]
2.9
Units per Package
1
Accessories
M Microswitches
278 - 280
9022125
262
Phone 1-973-575-7422
Fax 1-973-575-5858
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 2400VDC
[W]
28
38
45
56
60
72
75
80
98
[A2s]
32
46
82
128
228
512
1 150
2 050
3 330
[A2s]
260
380
700
1 050
2 400
4 200
9 400
16 700
27 100
* (L/R=15ms)
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9022126
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
1800V DC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2400V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
263
URDC
FUSES
URDC
Rated Voltage
[Un]
1800VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2400VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2 & SQB-DC2-2
Without
Rated
Indicator
Current
In
[A]
Article Number
With
Microswitch
Adapter
Article Number
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 2400VDC
[W]
[A2s]
[A2s]
58
68
82
96
130
175
1 700
3 000
5 300
9 100
16 100
26 600
13 500
24 000
42 700
73 500
131 000
216 000
Size SQB-DC2
100
125
160
200
250
315
9020125.100
9020125.125
9020125.160
9020125.200
9020125.250
9020125.315
9020126.100
9020126.125
9020126.160
9020126.200
9020126.250
9020126.315
355
9020125.355
9020126.355
177
30 700
288 000
400
9020125.400
9020126.400
Weight [kg/1]
3.54
Units per Package
1
180
55 400
401 000
* (L/R=15ms)
Accessories
M Microswitches
278 - 280
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9020125
9020125
264
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
1800VDC
Rated Breaking Test
Capacity
30kA
Voltage
2400VDC
Class Standard(s)
aR
IEC 60 077-5
UIC 550
Size SQB-DC2 & SQB-DC2-2
Without
Rated
Current
Indicator
In
[A] Article Number
With
Microswitch
Adapter
Article Number
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 2400VDC
[W]
[A2s]
[A2s]
202
273
368
372
378
36 400
64 400
160 400
158 800
221 600
294 000
524 000
864 000
1 152 000
1 604 000
* (L/R=15ms)
Size SQB-DC2-2
400
500
630
700
800
9021125.400
9021125.500
9021125.630
9021125.700
9021125.800
9021126.400
9021126.500
9021126.630
9021126.700
9021126.800
Weight [kg/1]
7.08
Units per Package
1
Accessories
M Microswitches
278 - 280
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9021125
9021126
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
265
URDC
FUSES
URDC
Rated Voltage
[Un]
1800VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
2400VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2 & SQB-DC2-2
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
266
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
Rated Voltage
[Un]
3600VDC
URDC
Rated Breaking Test
Class Standard(s)
Capacity
Voltage
3.2kA(L/R=16ms) 4000VDC
1.6kA(L/R=11ms)
aR
IEC 60 077-5
UIC 550
Size 40x254mm
Without
Indicator
Power
Loss
Article Number
9010010.2
9010010.3.15
9010010.3.9
9010010.5
9010010.6.3
9010010.8
9010010.12.5
9010010.16
9010010.20
Weight [kg/1]
2
Units per Package
1
[W]
9
13
24
18
22
21
40
23
27
Pre-arcing
Total
I2 t
I2 t*
@ 4000VDC
[A2s]
2.5
4
8
15
24
27
68
72
120
[A2s]
3.5
8
13
21
41
110
220
360
600
* (L/R=1ms)
9010010
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Time-Current Characteristics
Virtual Pre-arcing time - [s]
Rated
Current
In
[A]
2
3.15
3.9
5
6.3
8
12.5
16
20
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
267
URDC
FUSES
URDC
Rated Voltage
[Un]
3600VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
4200VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Rated
Current
In
[A]
40
50
63
80
100
125
150
Without
Indicator
With
Microswitch
Adapter
Article Number
Article Number
9022026.40
9022025.40
9022026.50
9022025.50
9022025.63
9022026.63
9022025.80
9022026.80
9022026.100
9022025.100
9022026.125
9022025.125
9022025.150
9022026.150
Weight [kg/1]
1.78
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 4200VDC
[W]
91
99
105
117
121
142
153
[A2s]
82
184
328
740
1 300
2 500
4 000
[A2s]
640
1 400
2 600
5 700
10 200
19 200
31 200
* (L/R=15ms)
Accessories
M Microswitches
278 - 280
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9022026
9022025
268
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
3600V DC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
4200V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC0
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
269
URDC
FUSES
URDC
Rated Voltage
[Un]
3600VDC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
4200VDC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2 & SQB-DC2-2
Rated
Without
Current
Indicator
In
Article Number
[A]
With
Microswitch
Adapter
Article Number
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 4200VDC
[W]
[A2s]
[A2s]
75
90
120
145
165
205
220
2 300
4 000
6 600
11 800
21 000
27 000
33 000
19 000
33 500
55 300
98 000
175 000
221 000
273 000
* (L/R=15ms)
Size SQB-DC2
100
125
160
200
250
280
315
9020025.100
9020025.125
9020025.160
9020025.200
9020025.250
9020025.280
9020025.315
9020026.100
9020026.125
9020026.160
9020026.200
9020026.250
9020026.850
9020026.315
Weight [kg/1]
3.54
Units per Package
1
Accessories
M Microswitches
278 - 280
9020025
270
Phone 1-973-575-7422
Fax 1-973-575-5858
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
9020026
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
3600VDC
Rated Breaking Test
Capacity
30kA
Voltage
4200VDC
Class Standard(s)
aR
IEC 60 077-5
UIC 550
SizeeSQB-DC2 & SQB-DC2-2
Rated
Without
Current
Indicator
In
Article Number
[A]
With
Microswitch
Adapter
Article Number
Power
Loss
Pre-arcing
Total
I2 t
I2 t*
@ 4200VDC
[W]
[A2s]
[A2s]
305
348
465
47 200
84 000
132 000
392 000
700 000
1 092 000
* (L/R=15ms)
Size SQB-DC2-2
400
500
630
9021025.400
9021025.500
9021025.630
9021026.400
9021026.500
9021026.630
Weight [kg/1]
7.08
Units per Package
1
Accessories
M Microswitches
278 - 280
9021026
9021025
Phone 1-973-575-7422
Fax 1-973-575-5858
M8 Contact Bolt
Maximum Torque
15N•m
11.1lb•ft
133lb•in
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
271
URDC
FUSES
URDC
Rated Voltage
[Un]
3600V DC
Rated Breaking Test
Capacity
30kA
Class Standard(s)
Voltage
4200V DC
aR
IEC 60 077-5
UIC 550
Size SQB-DC2 & SQB-DC0-2
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.25
B2
0.6
Cf3
0.8
Virtual Pre-arcing time - [s]
Time-Current Characteristics
R.M.S. Prospective Current [A]
272
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Standard(s)
Rated Voltage
Rated Breaking Test
Class
Capacity
[Un]
Voltage
gR
600VDC
600VDC(UL) gPV
30kA (L/R=5ms)
600VDC(IEC)
E180276
UL 248-13
IEC 60 269-6
Size 10x38mm
Rated
Current
In
[A]
1
2
3
4
5
6
8
10
12
15
16
20
25
30
Without indicator
Without indicator
PCB
Without indicator
50.6mm
Mounting
Article Number UL Article Number UL Article Number UL
5022526.1
9 5022626.1
9 5022726.1
9
5022526.2
9 5022626.2
9 5022726.2
9
5022526.3
9 5022626.3
9 5022726.3
9
5022526.4
9 5022626.4
9 5022726.4
9
5022526.5
9 5022626.5
9 5022726.5
9
5022526.6
9 5022626.6
9 5022726.6
9
5022526.8
9 5022626.8
9 5022726.8
9
5022526.10
9 5022626.10
9 5022726.10
9
9 5022626.20
9 5022726.20
9
5022526.20
9 5022626.15
9 5022726.15
9
5022526.15
9 5022626.16
9 5022726.16
9
5022526.16
9 5022626.20
9 5022726.20
9
5022526.20
9 5022626.25
9 5022726.25
9
5022526.25
9 5022626.30
9 5022726.30
9
5022526.30
Power
Loss
Total
I2 t
I2 t*
@600VDC
[A2s]
0.33
3
12
10
20
45
3
5
9
20
20
29
66
82
[W]
0.8
1.2
1.6
1.8
2.0
2.5
1.5
1.8
2.3
2.3
2.6
3.1
3.6
5.3
Power loss limit of
fuse base has to be considered
38
[A2s]
38
0.8
10.3
16.4
10.3
10.3
Pre-arcing
6.0
38
3.8
5022726
58.8
1.2
0.8
38.8
50.6
5.1
5022526
4.0
6.4
6.0
10.4
Time-Current Characteristics
5022626
Virtual Pre-arcing time - [s]
Coefficients for Heavy Duty Applications
a
130
A2
0.9
B1
1.25
B2
0.5
Cf3
0.8
R.M.S. Prospective Current [A]
Fuse Modules - DIN Rail Mounting w/Lockout Clip
5105805.1DC
1-Pole
5105805.1LDC 1-Pole w/neon lamp indicator
5105805.2DC
2-Pole
5105805.2LDC 2-Pole w/neon lamp indicator
Phone 1-973-575-7422
Fax 1-973-575-5858
Page
282
750V/50A
Fuse Clips
6100101.2
6301701
5805806
Page
Fuse Clips Screw mounting
Clamping plate for 6100101.2
Fuse Clips PCB mounting
287
E186970
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
273
URDC
FUSES
URDC
Rated Voltage
[Un]
1000VAC
Rated Breaking Test
Capacity
100kA
Class Standard(s)
Voltage
1000VAC
aR
IEC 60 269-40
VDE 0636 Part 40
Size NH3
Rated
Current
In
[A]
100
125
160
200
224
250
315
355
400
450
500
With
Top Indicator
Article Number
2040704.100
2040704.125
2040704.160
2040704.200
2040704.224
2040704.250
2040704.315
2040704.355
2040704.400
2040704.450
2040704.500
Weight [kg/1]
1.01
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t
@ 1000VAC
[W]
28
34
36
41
45
49
73
77
79
82
87
[A2s]
2 100
2 900
4 100
5 600
6 700
10 000
34 000
51 000
60 000
74 000
125 000
[A2s]
5 800
8 900
12 800
18 000
21 500
31 000
97 000
152 000
180 000
220 000
370 000
2040704
Accessories
Microswitch (Red Hammer)
Standard Level
2800202
2800204
Low Level
274
Phone 1-973-575-7422
Fax 1-973-575-5858
Page
Page
278
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
1000V AC
Rated Breaking Test
Capacity
100kA
Class Standard(s)
Voltage
1000V AC
aR
IEC 60 269-40
VDE 0636 Part 40
Size NH3
Coefficients for Heavy Duty Applications
a
130
A2
0.55
B1
1.3
Cf3
0.8
Time-Current Characteristics
Virtual Pre-arcing time - [s]
Cutoff Current - Peak [kA]
Cut-Off current Characteristics
B2
0.6
Prospective Short Circuit Current [kA]
(Symmetrical r.m.s.)
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
275
URDC
FUSES
URDC
Rated Voltage
[Un]
2000VAC
Rated Breaking Test
Capacity
100kA
Class Standard(s)
Voltage
2000VAC
aR
IEC 60 269-40
VDE 0636 Part 40
Size NH3
Rated
Current
In
[A]
200
224
250
300
315
355
400
450
With
Top Indicator
Article Number
2040404.200
2040404.224
2040404.250
2040404.300
2040404.315
2040404.355
2040404.400
2040404.450
Weight [kg/1]
1.7
Units per Package
1
Power
Loss
Pre-arcing
Total
I2 t
I2 t
@ 2000VAC
[W]
78
85
103
115
121
135
145
153
[A2s]
21 000
27 000
33 000
53 000
62 000
94 000
130 000
159 000
[A2s]
60 000
77 000
95 000
151 000
172 000
280 000
410 000
520 000
2040404
Accessories
Microswitch (Red Hammer)
2800202
Standard Level
2800204
Low Level
276
Phone 1-973-575-7422
Fax 1-973-575-5858
Page
Page
278
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
[Un]
2000VAC
Rated Breaking Test
Capacity
100kA
Class Standard(s)
Voltage
2000VAC
aR
IEC 60 269-40
VDE 0636 Part 40
Size NH3
Coefficients for Heavy Duty Applications
a
130
A2
0.65
B1
1.25
Cf3
0.8
Time-Current Characteristics
Virtual Pre-arcing time - [s]
Cutoff Current - Peak [kA]
Cut-Off current Characteristics
B2
0.6
Prospective Short Circuit Current [kA]
(Symmetrical r.m.s.)
R.M.S. Prospective Current [A]
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
277
URDC
FUSES
URDC
Accessories
Microswitch
GL Microswitch
Standard Level
Article Number
2800201
2800202
Insulating
Voltage
[V]
Change
Over
Circuits
[V]
ŷ
1
250
Interrupt Rating
AC
DC
[A]
5(resistive)
3(inductive)
[V]
33
26
[A]
3(resistive)
3(inductive L/R =10ms)
Low Level
Interrupt Rating
Minimum
2800203
2800204
Weight [kg / 1]
0.02
Units per Package
10
ŷ
1
5VAC
5VDC
Maximum
1mA(resistive)
30VAC
30VDC
2800201 / 2800203
2800202 / 2800204
(Black Hammer)
(Red Hammer)
0.3A
M Microswitch
Standard Level
Insulating
Voltage
[V]
ŷ
Article Number
2800104
Change Over
Circuits
1
Interrupt Rating (Resistive Load)
Minimum Load Requirement AC/DC
Maximum AC / DC
[V]resistive
[mA]
[A]
[V]
30
10
250
10
Low Level
ŷ
2801104
1
5
1
250VAC
35VDC
10
1
E186970
2800104 Standard
2801104 Low Level
278
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Accessories
Microswitch
B Microswitch
Standard Level
2800310
2800311
2800312
Weight [kg / 1]
0.025
Units per Package
10
2800320
2800321
2800322
Weight [kg / 1]
0.032
Units per Package
10
Insulating Change Over
Voltage
Circuits
1250
1
2200
1
5500
1
1250
2200
5500
Interrupt Rating (Resistive Load)
Maximum AC / DC
Minimum Load Requirement AC/DC
5V
50mA
30V
10mA
100V
5mA
250VAC
35VDC
12AAC
10ADC
2
2
2
Low Level
2800410
2800411
2800412
Weight [kg / 1]
0.025
Units per Package
10
2800420
2800421
2800422
Weight [kg / 1]
0.032
Units per Package
10
Insulating Change Over
Voltage
Circuits
1250
1
1
2200
5500
1
Interrupt Rating (Resistive Load)
Minimum Load Requirement AC/DC
Maximum AC / DC
DO NOT USE BELOW
5V
1250
2200
5500
Phone 1-973-575-7422
Fax 1-973-575-5858
1mA
250VAC
35VDC
10AAC
1ADC
2
2
2
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
279
URDC
FUSES
URDC
Accessories
Microswitch
B - Microswitch
2800310
2800410
2800311
2800411
2800320
2800420
2800321
2800421
2800312
2800412
2800322
2800422
Maximum Torque - 10N•m
Standard(s)
IEC 90947-3; AC20B, DC020B
9108001
280
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Rated Voltage
690VAC / 1000VDC
Fuse
Size
1
1 - Pole
Fuse Base
Article No.
2155601
Rated
Current
[A]
250
Rated Power
Acceptance
[W]
32
Accessories
Fuse Bases
Weight
[kg/1]
0.72
Standard(s)
IEC 60269-2
Units
per
Package
1
External Wall
Partition Wall
Article No.
2500301
Article No.
Insulating
Contact Covers
Article No.
2100301.26
2500301
2100301.26
2155601
URDC
E341490
Standard(s)
25 003
01
Rated Voltage
1000VDC - UL / IEC
5106305 DC 10mm x38mm Fuse Module
Article No.
10x38mm DIN Rail Mounting
Rated voltage; 1000VDC, UL / IEC
Rated current; 30A UL, 32A IEC
Power acceptance; 4W
Conductor solid; 0.75mm2 - 16mm2, 18AWG - 8AWG
UL 4248-1 & 18
IEC 60269-1 & 2
IEC 60947-1 & 2
UL 486E
CSA 22.2
Description
5106305.1DC
No indicator
1-Pole
5106305.1LDC
w/ Neon lamp indicator
5106305.2DC
No indicator
2-Pole
5106305.2LDC
w/ Neon lamp indicator
Fuse module current derating for adjacent pole with direct contatact
Number of Poles
De-rating factor
1.0XIn
1-3
0.8XIn
4-6
0.7XIn
7-9
0.6XIn
≥ 10
Conductor stranded; 0.75mm2 - 16mm2, 18AWG - 8AWG
Maximum torque; 2.5N•m - 3N•m, 18lb•in - 22lb•in
Utilization Category AC-21B 690V - DC-20B 1000V
Pollution degree; 3
Rated insulation voltage; Uimp = 6kV
Degree of protection; IP-20*
Construction, body & handle; Thermoplastic Polyester
Contacts; copper-silver plated
Flammability "UL 94"; V0
Operating temperature range; -50⁰C to +85⁰C**
Rating of light indicator; 350VDC - 1000VDC
*Depends on connection and mounting parts;
Contact SIBA for stranded wire ≤6mm2 or solid wire ≤ 10mm2
** Avoid handling of lever during installation or maitenance below -20⁰C
Important: DO NOT OPEN UNDER LOAD !
E341490
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
281
URDC
FUSES
URDC
Rated Voltage
690VAC - 1000VDC - IEC Accessories
Modules
w/lamp indicator
Standard(s)
CSA 22.2 Fuse
UL 4248-1
IEC 60269-1 & 2 IEC 60947-1 & 2
5105805 DC Series for 14x51mm 1000V Fuse Links
Article No.
14x51mm DIN Rail Mounting
Rated voltage; IEC 690VAC, 1000VC
Rated current; 50A UL, 50A IEC
Power acceptance; 6W
Description
5105805.1DC
No indicator
5105805.1LDC
w/ Neon lamp indicator
1-Pole
5105805.1SDC
w/ Microswitch
5105805.2DC
No indicator
2-Pole
5105805.2LDC
w/ Neon lamp indicator
Fuse module current derating for adjacent pole with direct contatact
Number of Poles
De-rating factor
1.0XIn
1-4
0.8XIn
5-6
0.7XIn
7-9
0.6XIn
≥ 10
Conductor solid; 1.5mm2 - 35mm2
Conductor stranded; 1.5mm2 - 25mm2
Torque rating; 2.5N●m - 3N●m, 18lb●in - 22lb●in
Utilization Category AC-21B 690V - DC-20B 1000V
Pollution degree; 3
Rated insulation voltage; Uimp = 8kV
Degree of protection; IP-20*
Construction, body & handle; Thermoplastic Polyester
Contacts; copper-silver plated
Flammability "UL 94"; V0
Operating temperature range; -40⁰C to +85⁰C**
Rating of light indicator; 350VDC - 1000VDC
*Depends on connection and mounting parts;
Contact SIBA for stranded wire ≤10mm2 or solid wire ≤ 10mm2
** Avoid handling of lever during installation or maitenance below -20⁰C
Important: DO NOT OPEN UNDER LOAD !
282
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
E186970
Rated Voltage
Standard(s)
750VAC/DC - UL
Accessories
UL 4248-1
CSA 22.2
690VAC/ - 750VDC - IEC Fuse Modules IEC 60269-1 & 2 VDE 0636-1 & 2
w/lamp indicator
IEC 60947-1 & 2 VDE 0660-100 & 107
5106305 DC Series for 10x38mm 750VAC/DC Fuse Links
10x38mm DIN Rail Mounting
Rated voltage; 750VAC/DC UL(rec), 690VAC - 750VDC IEC
Rated current; 30A - UL, 32A - IEC
Power acceptance; 4W
Conductor solid; 0.75mm2 - 16mm2, 18AWG - 8AWG,
Conductor stranded; 0.75mm2 - 16mm2, 18AWG - 8AWG
Torque rating; 2.5N●m, 18lb●in
Utilization Category AC-21B 690V - DC-20B 750V
Pollution degree; 3
Rated insulation voltage; Uimp = 6kV
Degree of protection; IP-20*
Construction, body & handle; Thermoplastic Polyester
Contacts; copper-silver plated
Flammability "UL 94"; V0
Operating temperature range; -50⁰C to +85⁰C**
Rating of light indicator; 120VAC/DC - 690VAC/DC
*Depends on connection and mounting parts;
750V/30A
Contact SIBA for stranded wire ≤6mm2 or solid wire ≤ 10mm2
** Avoid handling of lever during installation or maitenance below -20⁰C
Important: DO NOT OPEN UNDER LOAD !
Phone 1-973-575-7422
Fax 1-973-575-5858
Article No.
5106305.1
No indicator
1-Pole
5106305.L
w/ Neon lamp indicator
5106305.2
No Indicator
2-Pole
5106305.2L
w/ Neon lamp indicator
5106305.3
No Indicator
3-Pole
5106305.3L
w/ Neon lamp indicator
5106305.4
No Indicator
4-Pole
5106305.4L
w/ Neon lamp indicator
Fuse module current derating for adjacent pole with direct contatact
Number of Poles
De-rating factor
1.0XIn
1-4
0.8XIn
5-6
0.7XIn
7-9
0.6XIn
≥ 10
E186970
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
283
URDC
FUSES
Rated Voltage
1000VAC
URDC
E186970 Size
NH000/00 DIN 80
Rated Current
400A
Power Acceptance
34W
Accessories
Fuse Bases
2118901
289 08
A
B
B1
B2
C
D
E
F
G
G1
G2
H
I
J
K
Lmax
L1
L2
M
N
21 189 01
4.96 / 126
1.57 / 40
ŷ
ŷ
0.50 / 13
0.75 / 19
3.15 / 80
0.12 / 3
1.73 / 44
ŷ
ŷ
4.40 / 112
0.26 / 6.5
0.60 / 15.5
0.63 / 16
5.75 / 146
ŷ
ŷ
M8
0.98 / 25
Dimensions
[in / mm]
21 189 08
4.96 / 126
ŷ
1.57 / 40
1.34 / 34
0.50 / 13
0.75 / 19
3.15 / 80
0.12 / 3
1.81 / 46
ŷ
ŷ
21 189 11
4.96 / 126
ŷ
ŷ
0.50 / 13
0.75 / 19
3.15 / 80
0.12 / 3
ŷ
2.00 / 51
1.73 / 44
2.91 / 74
0.26 / 6.5
0.60 / 15.5
0.63 / 16
ŷ
5.75 / 146
6.50 / 165
4.40 / 112
0.26 / 6.5
0.60 / 15.5
0.63 / 16
5.75 / 146
ŷ
ŷ
M8
0.98 / 25
M8
0.98 / 25
Max M8 nut torque
12N•m
8.8lb•ft
106lb•in
Max base mounting torque
4N•m
3lb•ft
35lb•in
2118911
284
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Accessories
Fuse Bases
0
36mmx190mm
91090 1
20mmx190mm
9109601
2000VDC - 36mmx250mm
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
285
URDC
FUSES
URDC
Accessories
Fuse Clips
Fuse Clips for 10mm Diameter Contacts
Dimensions
[ in / mm]
5806316
5806316
0.43 / 11.0
0.47 / 12.0
0.71 / 18.0
0.14 / 3.6
0.08 / 2.0
ŷ
ŷ
0.03 / 0.65
0.43 / 11.0
0.18 / 4.45
0.06 / 1.5
0.22 / 5.5
0.45 / 11.5
A
B
C
D
E
E1
E2
F
G
H
I
J
L
5806319
0.43 / 11.0
0.47 / 12.0
0.71 / 18.0
0.14 / 3.6
ŷ
0.08 / 2.0
0.12 / 3.0
0.03 / 0.65
0.43 / 11.0
0.18 / 4.45
0.06 / 1.5
0.22 / 5.5
0.45 / 11.5
5806319
Dimensions
[ in / mm]
5806317
0.43 / 11.0
0.47 / 12.0
0.71 / 18.0
0.17 / 4.2
ŷ
0.03 / 0.65
ŷ
ŷ
0.06 / 1.5
0.22 / 5.5
A
B
C
D
E
F
G
H
I
J
6301701
0.39 / 10.0
0.35 / 9.0
0.08 / 2.0
0.17 / 4.2
ŷ
ŷ
ŷ
ŷ
ŷ
ŷ
6301701
5806317
Dimensions
[ in / mm]
A
B
C
D1
D2
E
F
G
6101701.3
0.83 / 21.0
0.24 / 6.0
0.08 / 2.0
ŷ / M5
ŷ / M4
0.61 / 15.5
0.43 / 11.0
0.22 / 5.5
6101701.3
286
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Accessories
Fuse Clips
Fuse Clips for 14mm Diameter Contacts
Dimensions
[ in / mm]
6100101.2
6100101.2
0.61 / 15.5
0.61 / 15.5
0.90 / 22.8
0.17 / 4.2
0.03 / 0.7
0.06 / 1.5
0.26 / 6.5
0.57 / 14.5
A
B
C
D
F
I
J
L
6301701
0.39 / 10.0
0.35 / 9.0
0.08 / 2.0
0.17 / 4.2
ŷ
ŷ
ŷ
ŷ
6301701
Dimensions
[ in / mm]
5805806
0.63 / 16.0
0.47 / 12.0
0.61 / 15.5
5805806
0.14 / 3.5
0.20 / 5.0
0.03 / 0.70
0.42 / 10.7
0.17 / 4.2
0.04 / 1.0
0.12 / 3.0
0.33 / 8.5
A
B
C
D
E
E1
E2
F
G
H
I
K
L
Fuse Clips for 22mm Diameter Contacts
Dimensions
[ in / mm]
6100201.3
Phone 1-973-575-7422
Fax 1-973-575-5858
6100201.3
0.73 / 18.5
0.72 / 18.4
1.42 / 36.0
0.18 / 4.2
0.31 / 8.0
0.05 / 1.2
0.31 / 8.0
0.08 / 2.0
0.16 / 4.0
0.98 / 25.0
A
B
C
D
E
F
G
I
J
L
6300201
0.73 / 18.5
0.59 / 15.0
0.12 / 3.0
ŷ / M4
0.31 / 8.0
ŷ
0.31/ 8.0
ŷ
0.16 / 4.0
ŷ
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
6300201
e-mail: [email protected]
www.siba-fuses.us
287
URDC
FUSES
URDC
Accessories
Fuse Clips
Fuse Clips for 22mm Diameter Contacts
Dimensions
[ in / mm]
A
B
C
D1
D2
E
F1
F2
G
6100201.4
1.40 / 35.5
0.59 / 15.0
0.12 / 3.0
ŷ / M4
ŷ / M6
0.31 / 8.0
0.30 / 7.5
0.31 / 8.0
0.31 / 8.0
6100201.4
Dimensions
[ in / mm]
5806006
0.67 / 17.0
0.79 / 20.0
0.91 / 23.0
0.08 / 2.0
5806006
0.24 / 6.0
0.14 / 3.5
0.03 / 0.8
0.42 / 10.7
0.17 / 4.2
0.04 / 1.0
0.13 / 3.2
0.49 / 12.5
A
B
C
D
E
E1
E2
F
G
H
I
K
L
Fuse Clips for 27mm Diameter Contacts
Dimensions
[ in / mm]
6100401.3
288
Phone 1-973-575-7422
Fax 1-973-575-5858
6100401.3
0.73 / 18.5
0.91 / 23.2
1.79 / 45.5
0.17 / 4.3
0.31 / 8.0
0.05 / 1.2
0.31 / 8.0
0.08 / 2.0
0.16 / 4.0
1.14 / 29.0
A
B
C
D
E
F
G
I
J
L
6300201
0.73 / 18.5
0.59 / 15.0
0.12 / 3.0
ŷ / M4
0.31 / 8.0
ŷ
0.31/ 8.0
ŷ
0.16 / 4.0
ŷ
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
6300201
e-mail: [email protected]
www.siba-fuses.us
URDC
FUSES
URDC
Accessories
Fuse Clips
Fuse Clips for 36mm Diameter Contacts
Dimensions
[ in / mm]
9109401.3
1.38 / 35.0
0.98 / 25.0
2.17 / 55.0
0.33 / 8.5
0.20 / 5.1
0.06 / 1.5
0.49 / 12.5
ŷ
ŷ
0.31 / 8.0
0.20 / 5.0
1.38 / 35.0
A
B
C
D1
D2
F
G
G1
G2
I
J
L
9109401.4
2.48 / 63.0
0.79 / 20.0
0.24 / 6.0
0.33 / 8.5
0.20 / 5.1
ŷ
ŷ
0.49 / 12.5
1.36 / 34.5
ŷ
0.69 / 17.5
ŷ
9109401.4
9109401.3
Phone 1-973-575-7422
Fax 1-973-575-5858
SIBA LLC
29 Fairfield Place
West Caldwell, New Jersey 07006
e-mail: [email protected]
www.siba-fuses.us
289

Similar documents

Siba 2014 Brochure update

Siba 2014 Brochure update DC Sizes: 10x38mm, 14x51mm, 22x58mm, 27x60mm, 20x127mm, 20x190mm, 36x190mm, 40x254mm, NH000 DIN80, SQB-DC0 &2, SQB-DC2-2 (double), SQB-DC90, 1, & 2, SQB DC92-2 (double body), SQB-DC93, SQB-DC93-2 (...

More information

Miniature Fuses

Miniature Fuses 7.2 Operation at extra-Low-Voltage Ub << Urat Fuse-links can operate without difficulty at voltages below their rated voltage. The voltage drop of the fuse-links (internal resistance) must be taken...

More information