50% CD Theatrical Cu..
Transcription
50% CD Theatrical Cu..
ETC Element Control Console ® ™ Eos Series ® G E N E R A L I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Designed for venues using primarily conventional lighting, the Element control console provides the powerful features of the Eos system in an economical and simplified package. In addition to keypad commands, True LTP Channel Faders provide hands-on control of intensity and can be used to set manual levels and edit recorded cues and submasters. On Demand Moving Light Controls are available to facilitate using conventional accessories like moving mirror heads, color scrollers or gobo rotators, or to make controlling small numbers of moving lights simple and direct. Element ™ Element Console, 40 Faders, 250 Channels LMNT-40-500 Element Console, 40 Faders, 500 Channels LMNT-60-250 Element Console, 60 Faders, 250 Channels LMNT-60-500 Element Console, 60 Faders, 500 Channels T wo universes of DMX512-A output are available at the console via 5-pin XLR, or these universes may be distributed with ETCNet2 DMX Nodes or Net3 DMX/RDM Gateways. Gateways and network equipment must be purchased separately. Element Accessories MODEL DESCRIPTION Net3 RFR Net3 Radio Focus Remote Net3 RVI Net3 Remote Video Interface (Element supports Mirror Mode* operation only) Net3 RFR-RX Net3 Radio Focus Remote, Receiver Only Net3 RFR-TX Net3 Radio Focus Remote, Transmitter Only M231 19” LCD touch screen monitor (1280x1024) *Mirror Mode provides remote display and paging of the same screens that are displayed on the console itself. There is no additional interaction with the console allowed in Mirror Mode. Computers running Element Offline may be connected to the Element console via Ethernet as a Mirror Mode Client without the need for any additional security hardware keys. ™ ® ® DESCRIPTION LMNT-40-250 ETCNet2 or Net3 are distributed using Net3 Gateways, which provide DMX, MIDI/ SMPTE Time Code and switch-closure functionality. MIDI In/Out is also available locally at the console. APPLICATIONS • Theatre • Television Studios • Houses of Worship • Corporate Theatre • Exhibits • Special Events • Touring FEATURES • 1024 Outputs • 250 or 500 Channels • 40 or 60 Fader versions, pageable as channel or submaster control • Master Playback pair with 60mm faders, Go, Stop/Back • Intensity, Focus, Color and Beam Palettes • Stepped, Relative and Absolute Effects • Hue+Saturation Color Picker and Gel Picker for LED, CMY color mixing • ETCNet2 , Net3 /ACN, ArtNet and Avab UDP network protocols • Show import from Obsession , Express , Expression , Emphasis , Congo and Strand 500/300 Series via ASCII • I/O: local DMX512-A (2 output ports), MIDI In/Out, Ethernet • Distributed DMX, MIDI, SMPTE and contact closure via Net3 Gateways ™ MODEL ® ® SHIPS WITH: • Dust Cover • Mouse and Mousepad 1 of 4 ETC Element Control Console ® ™ Eos Series ® S P E C I F I C AT I O N S S P E C I F I C AT I O N S SYSTEM CAPACITY • 1024 Outputs/Parameters • 250 or 500 Channels • 10,000 Cues • 1 Cue List • 4 x 1000 Palettes (Intensity, Focus, Color, Beam) • 1000 Groups • 1000 Effects (relative, absolute or step) • 1000 Macros • Supports two external DVI monitors or one VGA monitor with a minumum of 1280x1024 resolution, which may also be touch screens • Hard Disk • USB ports for flash drives, pointing devices, keyboards DISPLAY FUNCTIONS • All show data may be viewed on one or two external monitors. Views may be expanded across both from easily accessed front panel controls • The Central Information Area accesses: -- Browser -- File Management -- System Setup -- Network Configuration -- Show Data Utilities -- Printing -- Record Target Lists -- Patch functions -- Help -- Hue and Saturation Color Picker and Gel Picker -- On Demand Moving Light Controls -- Electronic alpha keyboard -- Command Line -- Selected Cue -- Error messages and advisories • Channel Displays -- Live channel summary or table view -- Blind cue, palette and submaster views, in list, channel, table and spreadsheet formats -- Flexi-channel to determine which channels to display -- Zoom allows user to define how many channels are viewed -- Color coded intensity levels indicate direction of move -- Color coded non-intensity levels indicate change from previous state -- Graphic differentiation of moving lights, single parameter devices, unpatched channels and deleted channels • Patch Views -- Patch by channel -- Patch by address -- Assign proportional patch value, curve, preheat value for intensity -- Swap pan and tilt -- Invert pan and tilt -- Custom fixture editor • Playback Status Display -- Graphic representation of cue list status, past and future cues • Cue List Index • Effect Editor • Group Editor • Park Display • Fader Display -- Isolates display to active output by fader contribution • Dimmer Monitoring PLAYBACK CONTROLS • Master Playback crossfade pair with two 60mm potentiometers, Go, Stop/Back and Load buttons • Grand Master with Blackout • Playback fader controls include: -- Timing Disable -- Off -- Release -- Manual Override -- Rate • A maximum of 300 submasters (additive or inhibitive) via integral faders MOVING LIGHT CONTROLS • On Demand Moving Light controls include labeling and current parameter value on connected display monitor • Flip and Home functions • Parameters selectable on screen for mouse-based or touch screen control or command line actions 2 of 4 ETC Element Control Console ® ™ Eos Series ® S P E C I F I C AT I O N S S P E C I F I C AT I O N S ---------- Auto-mark Block at cue, intensity or parameter level Follow times Out of sequence link Loop functions Preheat enable 20 part multi-part cues with default part assignment Cue level rate override Up to 99 decimal cues between each two whole numbered cues -- Execute List ·· Triggers macros with delay ·· Show control triggers ·· Analog triggers -- Update and Update Trace functions -- Undo record and delete • Submasters -- Additive, inhibitive or effect submasters -- Bump button timing to fade up, dwell and fade out -- Exclusive and Shielded modes -- Faders as progress controller or intensity master -- Bump button to mark NPs -- Independent status • Curves -- Assignable in patch to modify dimmer output ramp -- Assignable at cue or cue part level to modify intensity crossfade profle or non-intensity parameter ramping INTERFACES • 2 DMX-512 Ports (RDM ready) • Ethernet (ETCNet2 , Net3 ,Artnet and Avab UDP protocols) • Contact Closure triggers via D-Sub connector • 2 DVI video connectors support two external DVI displays (1280x1024) with optional touch screen control • 1 - VGA connector • USB Multi-purpose (minimum 5 ports) • Phone Remote • Net 3 Radio Focus Remote • MIDI In/Out (Timecode, Show Control) • Additional MIDI/SMPTE Timecode, Show Control through Net3 Gateway • Additional contact closure (12 analog inputs, 12 SPDT contact outputs, RS-232) through Net3 Gateway ELECTRICAL • AC input (100-240V at 50/60 Hz) • 2 amps at 120V or 1 amp at 240V maximum power consumption MANUAL CONTROL • Channel selection from keypad • Lists constructed with +, -, thru • Intensity set with level wheel, keypad, “full” and “out” • True LTP channel faders for direct hands-on intensity control • Ordered groups • Offset, including even, odd, random, reverse • Sneak • Remainder Dim and restore • Home by parameter, parameter category or all non-intensity parameters • Park at level • Scaled park for temporary percentage adjustment • Recall from and Copy to commands • About provides detailed view of selected channels or record targets • Undo manual control, record, update and delete operations • Lamp controls to strike, douse, calibrate fixtures PROGRAMMING FEATURES • Channel Functions -- Non Intensity parameters set via numeric entry or On Demand Moving Light Controls -- Color matching to gel selector or Hue/Saturation color picker • Palette Functions -- Record and Update functions -- Toggle display to absolute data -- Up to 99 decimal values may be inserted between any two whole numbers -- Selective store to refine contents of record targets • Effects -- Create live or blind -- Pattern based relative dynamic effects -- Absolute effects -- Step effects -- Cycle time, trail and grouping determine channel distribution and behavior when moving through effect -- Duration of infinite, a specific amount of time or number of passes through pattern -- Effect attributes to modify basic behavior -- Cue Level Overrides to modify size, rate and form -- Multi-part effects easily synchronize parameter activity -- Entry mode determines how parameters enter effects -- Exit mode determines how parameters depart effects • Cue Recording -- Record tracking or cue-only -- Autoplayback recorded cues ™ 3 of 4 ™ ETC Element Control Console ® ™ Eos Series ® PHYSICAL Element Console Dimensions Element Console Weights * MODEL Element Console HEIGHT * WIDTH DEPTH inches mm inches mm inches mm 5.1 130 32.9 836 17.9 455 MODEL Element Console WEIGHT SHIPPING WEIGHT lbs kgs lbs kgs 30 13.6 37.5 17 *Weights and dimensions typical 17.9” 455 mm 32.9” 836 mm 5.1” 130 mm Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0) 20 8896 1000 • Fax +44 (0) 20 8896 2000 Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2011 ETC. All Rights Reserved. All product information and specifications subject to change. 4330L1003 Rev F Printed in USA 04/11 4 of 4 ETC Connector Strips Distribution Series O R D E R I N G I N F O R M AT I O N Prefix + Length 99 + L Quantity of Connector Connector connector Type* Mounting Q 1,2,3... Amp rating C M @A (A) U-ground (P) Pigtail optional (B) Stage pin (O) Outlet default 20amp (C) Twistlock (D) DMX Quantity of circuit Terminal location Hanger X 1,2,3... T H (R)ight See (L)eft hanger (C)enter page * For outlets not listed, use manufacturer's part number (must be UL listed). Basic model numbering 99L-QCM/X-T-H This is the basic form of the model number. It reads: 99 Length; Quantity; of Connector; Mounting (pigtail or panel); on X number of circuits; Terminal location; Hanger bracket type. Example: 9940-16BP/8-R-21. This is a connector strip (99) forty feet long with sixteen stage pin pigtails wired on eight circuits, terminals located on the right of the open side of the connector strip with type 21 hanger brackets. Additional standard connector types S P E C I F I C AT I O N S CONNECTOR STRIPS 18-gauge steel construction (14 ga. end caps and junction brackets for increased strength) Designed for easy shipment, installation, and service Available with DMX outlets (for scroller and moving light control) Finished with textured black-powder coat (other colors available) Shipped standard 6’ lengths, completely wired through and folded; splicing hardware included (optional 12’ or 18’ factory assembled solid lengths are available) Standard and custom lengths and circuitry are available Individual circuits can have multiple outlets Panel mount outlets or pigtail connectors 20 amp parallel-blade (Edison)(type A) 20, 50 or 100 amp grounded stage pin (type B) 20 amp Twist-lock® (type C) Multipin and other connectors available on request (i.e., VSC, Pyle National, 30 amp stage pin, 50 amp twistlock …) 2” high white-on-black circuit labels standard one side (other labeling available: 2 side polycarbonate labels, 1 and 2 side engraved lamicoid labels, or 1 side engraved covers) DIN rail mounted screwless “tension clamp” wire terminals 20 amp circuits, maximum wire size: 8 gauge Screw terminals for 50 and 100 amp circuits. Maximum wire size for 50 amp: 1 gauge. Maximum wire size for 100 amp: 2/0 Wide variety of mounting and hanger brackets available — (see Brackets) New packaging protects strips and aids in installation 99L-(QCM/X)(QCM/X) -T- H For additional connector types the form is the same as above except we group all connector types in parentheses to avoid confusion. You can add as many connector types as you need. Example: 9950-(20CP/20)(4AO/1)-L-22. This strip has twenty Twistlock™ pigtails wired on twenty circuits (one to one) and four Edison outlets wired on one circuit for work lights, terms left and type 22 hangers. Connectors other than 20 Amp 99L-(QCM/X)(QCM@50/X) -T- H For all but 20 amp connectors you must specify the amperage they are rated for. The form is the same except you add the current rating like this: @ Amps. Example: 9950-(20BP/20)(4BO@50/4)-L-22. This strip has twenty stage pin pigtails wired on twenty circuits and four stage pin outlets at 50 Amps wired on four circuits, terms left and type 22 hangers. Non-standard connector types 99L-(QCM/X) (Q*Mfg. Model #/X) (QCM/X) -T- H Non-standard connector types must be UL listed to maintain the UL listing of the connector strip. Their model numbering is similar with two exceptions. 1) Use the manufacturers model or part number separated by an asterisk (hyphens separate electrical from mechanical information) 2) Mounting information is unnecessary because it is included in part number. Example: 9950-(20BP/20)(8*HBL2410/4)(4AO/1) -L-22. This strip has twenty stage pin pigtails wired on twenty circuits, eight HBL2410’s wired on 4 circuits for moving lights and four Edison outlets wired on one circuit for work lights, terms left and type 22 hangers. DMX in Connector Strips 99L-(QCM/X) (Q*Mfg. Model #/X) (QCM/X) (8D/2) -T- H DMX model numbering (DMX rules and details on back page): 1) Show number of DMX panels on number of universes (maximum of two universes, or call factory) 2) Mounting information is unnecessary because it is a panel mount assembly. Example: 9950-(20BP/20)(8*HBL2410/4)(4AO/1)(8D/2) -L-22. This is the same connector strip as above with the addition of the DMX pass through panels to control the moving lights. M U LT I C O N D U C T O R C A B L E A N D A C C E S S O R I E S 9700 Model Gridiron junction box Rigging (by others) DMX Gridiron Junction Box Cable cradle (See table below) Kellems grip™ Strain Relief (See table below) 9900 Series Connector Strip DMX input cable DMX input box Kellems grip™ Strain Relief Kellems Support Grip™ Panel-Mount Outlet "Pigtail" Connector ETC recommends using an additional strain relief for attaching multicable to fixture pipe (Pipe by others) * Hanger brackets should be mounted every five feet. Cable and Accessory Specifications with ETC Part #'s Cable Part # OD 12/3 12/9 12/14 12/20 12/26 12/30 12/37 10/3 10/4 10/5 10/10 10/16# 10/20# 6/3 6/5 W707 W721 W718 W713 W715 W716 W717 W512 W516 W517 W513 W514 W515 W814 W815 .610 .915 1.105 1.315 1.453 1.535 1.653 .671 0.73 0.83 1.12 1.305 1.44 0.885 1.09 LB/FT .24 .60 .85 1.10 1.45 1.54 1.65 .31 0.371 0.496 0.98 1.19 1.45 0.76 1.14 Kellems® Strain Relief Grips Kellems® Deluxe Cord Grips Kellems® Standard Support (pickup) Double eye Cable Cradle HW633 HW634 HW635 HW636 HW636 HW636 HW637 HW633 HW633 HW634 HW635 HW636 HW636 HW634 HW635 HW6186 HW6188 HW6189 HW6191 HW6192 HW6192 HW6193 HW6187 HW6187 HW6187 HW6189 HW6191 HW6192 HW6188 HW6189 Hw6206 HW6208 HW6209 HW6210 HW6210 HW6211 HW6211 HW6207 HW6207 HW6208 HW6209 HW6210 HW6210 HW6208 HW6209 N/A PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 PSE8804 # Requires minimum order and extended lead time, call for details. Strain Relief Grips and Deluxe Cord Grips are not intended to support loads. See Hubbell technical section for Support Grip ratings and safety factors. DMX "Pass-Thru" Panel Mounting Hanger Brackets Fixture Pipe (by others) Connector Strips Distribution Series Types 11 through 18 are Mounting Brackets and are intended to support the connector strip only and not intended to support a pipe. No mounting hardware is supplied with type 11, 12, and 13 because it is the installers responsibility to determine the appropriate mounting hardware. Type 11 16.00" 21.5" 14.70" Type Usage and Notes 11 Mounts strips with the 6.25" dimension parallel to and directly on a wall or ceiling. No mounting hardware is supplied. Mounts strips with the 3.3" dimension parallel to and directly on a wall or ceiling. No mounting hardware is supplied. Mounts strips in a corner. No mounting hardware is supplied. Mounts strips to a pipe with the 6.25" dimension parallel to the floor over a grid. Bracket is attached to the pipe with a U-bolt. Stiffeners should be bolted between connector strips (not provided). Same as 14 w/vertical segment of hanger bolted together to allow mounting at any angle over pipe Similar to 14 but mounts strips to pipes with the 6.25" dimension perpendicular to the floor. The u-bolt can be mounted from either side making this hanger useful for any application where a connector strip is mounted to a pipe Same as 16, but the vertical segment of the hanger is bolted together to allow the connector strip to be mounted at any angle to the pipe Use where a connector strip is mounted directly on a pipe at 90 degrees 12 13 14 Type 21 Type 12 Type 26 15 16 Type 13 17 (2) 28.00" 18 9.25" (2) 25.00" Types 21 through 26 are Hanger Brackets and support both the connector strip and 1.5" schedule 40 pipe (1.9" O.D.) 22.16" 21.25" Type 14 † Type Usage and Notes 21 The default hanger, this unit hangs the connector strip and a pipe to a fly system. The .75" hole in the top of the bracket is for shackles or thimbles. Designed to hang the connector strip and a pipe from a system pipe already installed. Similar to 22, but designed to support the connector strip and the term box at the end of the pipe (This unit is automatically substituted for one 22 when a strip has a term box; do not order) Hangs the connector strip and a pipe from a system pipe (already installed in a fly system) to under hang fixtures from both pipes. The .75" hole in the top of the bracket for shackles or thimbles can be used to hang both pipes. Similar to 24, but designed to support the connector strip and the term box at the end of the pipe (This unit is automatically substituted for one 24 when a strip has a term box; do not order) Similar to 23 but 7" shorter. Use where space is a concern. Cannot be used on connector strips with term boxes. The .75" hole in the top of the bracket is for thimbles and wire rope. 22 9.25" Type 22 23 Type 32 (2) Type 23 (2) Type 33 Type 15 † 24 25 12.25" 23.00" 26 Type 16 † Types 31 through 34 are "flat" Hanger Brackets that support both the connector strip and 1.5" schedule 40 pipe (1.9" O.D.) (Note: These do not center hang loads). 12.25" Type 34** 48.00" Type 17 † (2) 42.16" Type Usage and Notes 31 32 33 34 Straight version of the 21 hanger. Pipe attached with U-bolts. Straight version of the 22 hanger. Pipe attached with U-bolts. Straight version of the 23 hanger. Pipe attached with U-bolts. Unit is designed to mount a connector strip on catwalk railings. Place u-bolts from 11.8" to 16.6 inches center to center using four positions on the top and slots on the bottom of bracket to cover a range of spacing. 18.00" (2) 14.5" 13.25" Type 18 † Designed for use with Unistrut stiffener for grid applications—these hangers not intended to support pipe. Type 24 (2) Type 25 Type 31 (2) Type 35 Note: Clamps and U-bolts on mounting brackets are designed to be used with 1.5" I.D. Schedule 40 steel pipe. (1.9" nominal O.D.) Type 23, 25, & 33 are automatically supplied for connector strips w/terminal boxes Connector Strips Distribution Series DMX CONNECTOR STRIPS DMX Pass Thru Panel Side View PUSH Top View Pass Thru DMX Output To device DMX Input From device Switch Guard Detail Pass Thru "engaged" when green DMX data originates from an optically isolated DMX 512 source (opto-splitter) Last device on this segment should be terminated with termination switch on that device Using both jacks and terminating at the same time may yield unpredicable results. DMX Pass Thru • Wire from the DMX output to DMX controlled device (moving light or scroller) with a 5 pin DMX cable. • Wire from DMX out on device to pass thru panel so DMX is routed to next location on strip • Engage the Pass Thru switch (center will turn green) to route DMX past unused locations. • The last device on a connector strip should be terminated with the termination switch on the device. • DMX should originate from an optically isolated source for each connector strip. • This system maintains a linear DMX segment eliminating common DMX wiring problems. Fixture Fixture PHYSICAL Connector Types Cross Section DMX barrier as required. Connector Connector Connector type B type A 20A parallelblade U-Ground type C 20, 50 or 20A grounded 100A pin twist-lock® connector Nema L5•20R (20 Amp Shown) (A.K.A. Edison) Nema 5•20R (Hubbell®) (Hubbell®) 6.25"/15.9cm 3.3" 8.4cm Americas 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979, USA Europe Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK ■ ■ Tel +1 608 831 4116 ■ Fax +1 608 836 1736 ■ Toll free 800 688 4116 ■ Toll free fax 800 555 8912 Tel +44 (0)20 8896 1000 ■ Fax +44 (0)20 8896 2000 Asia Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Web www.etcconnect.com ■ Email (US) [email protected] ■ (UK) [email protected] ■ ■ Tel +852 2799 1220 (Asia) [email protected] Copyright © 2004 ETC. All Rights Reserved. All product information and specifications subject to change. 7099L1002 Rev. C Printed in USA 12/04 ■ Fax +852 2799 9325 ETC® Fresnel Series Y R A N I IM L E PR G E N E R A L I N F O R M AT I O N S P E C I F I C AT I O N S ETC combines the efficiency of the HPL lamp with the singular optical qualities of the fresnel optical system to create the truly advanced ETC Source Four Fresnel. Traditional fresnel optics provide a unique quality of blending wash light and beam shaping via barn doors for well-defined, soft-edged area lighting. The Source Four Fresnel combines this classic system with a unique reflector design enabling the HPL 750W-equipped Source Four Fresnel to equal the lumen output of other 1000W fresnel fixtures. Spot-to-flood focus is accomplished by large, easy-to-use knob for quick adjustments in inconvenient positions. The unique Quick Xchange socket design permits re-lamping from underneath the fixture without breaking focus in most situations. LAMP • HPL – compact tungsten filament contained in a krypton/ xenon-filled quartz glass envelope (see table for suitable lamp types) • Uses same lamp as all Source Four fixtures for common inventory • 750W maximum • Patented filament geometry makes for extremely efficient light collection and transmission • Integral die-cast aluminum heat sink lamp base S P E C I F I C AT I O N S Source Four Fresnel O R D E R I N G I N F O R M AT I O N PHYSICAL • Rugged die-cast aluminum construction • Convenient full-size zoom adjustment knob • Unique HPL quick exchange socket enables easy lamp changes • Sliding yoke mount for variable balance point • Fully enclosed accessory slots for no light leak • UL and cUL listed ELECTRICAL • 100V-240V, 50/60Hz • High temperature three-conductor 36” leads in a glass fiber outer sleeve • Supports ETC Dimmer Doubling™ technology OPTICAL • 7”/175mm aperture • 20° - 65° field angle zoom range • True fresnel optical system for good barn-door beam shaping performance • Glass reflector with dichroic coating optimized for HPL performatnace MODEL DESCRIPTION FRES7 7” Source Four Fresnel (Black) FRES7-1 7” Source Four Fresnel (White) Connector Designation Use suffixes below to specify factory–fitted connector type MODEL DESCRIPTION A Parallel-blade U-ground connector (Edison) B Two-pin and ground, 20A connector C Grounded 20A twist lock connector M Dimmer Doubling Connector (NEMA L515P) See back page for Source Four Fresnel accessories 1 of 6 ETC® Fresnel Series PHOTOMETRICS Photometric data below is measured with an HPL 750W/115V 300 hr lamp. To convert data when using any other HPL lamp, use the lumen or candela multiplying factors (Lm MF or Cd MF) for that specific lamp. These multiplying factors are listed in the Lamps table in this datasheet. For lumen data, multiply by the Lm MF. For candela or footcandle data, multiply by the Cd MF. Source Four Fresnel - Flood Focus (115V) Degree Candela Field Lumens 65° 17,600 10,690 Iso-Illuminance Diagram Beam Lumens Lumens per Watt 7,590 14.3 (Flat Surface Distribution) Y 10% For field diameter at any distance, multiply distance by 1.262 For beam diameter at any distance, multiply distance by .978 65˚ Field Angle 52˚ Beam Angle X 50% .059 .118 .176 .235 15.0’ 4.6m 20.0’ 6.1m 25.0’ 7.6m Field Diameter 12.6’ 3.8m 18.9’ 5.8m 25.2’ 7.7m 31.5’ 9.6m Illuminance (fc) 176 78 44 28 1,894 842 474 303 Illuminance (lux) Candela Plot Candela Throw Distance (d) 10.0’ 3.0m 18000 16000 14000 12000 10000 8000 6000 4000 2000 0 -35 -30 -25 -20 -15 -10 -5 X Y 0 5 10 15 20 25 30 35 Degrees Source Four Fresnel - Medium Focus (115V) Iso-Illuminance Diagram Degree Candela Field Lumens Beam Lumens Lumens per Watt 40° 51,500 7,390 3,580 9.9 (Flat Surface Distribution) Y 10% For field diameter at any distance, multiply distance by 0.716 For beam diameter at any distance, multiply distance by 0.367 40˚ Field Angle 21˚ Beam Angle X 50% .059 .118 .176 .235 15.0’ 4.6m 20.0’ 6.1m 25.0’ 7.6m Field Diameter 7.2’ 2.2m 10.7’ 3.3m 14.3’ 4.4m 17.9’ 5.5m Illuminance (fc) 515 229 129 82 5,543 2,464 1,386 887 Illuminance (lux) Candela Plot 60000 50000 Candela 10.0’ 3.0m Throw Distance (d) 40000 X 30000 Y 20000 10000 0 -25 -20 -15 -10 -5 0 Degrees 2 of 6 5 10 15 20 25 ETC® Fresnel Series PHOTOMETRICS Source Four Fresnel - Narrow Focus (115V) Iso-Illuminance Diagram Degree Candela Field Lumens Beam Lumens Lumens per Watt 20° 124,300 3,.990 1,930 5.3 (Flat Surface Distribution) Y 10% For field diameter at any distance, multiply distance by 0.42 20˚ X Field Angle 9˚ Beam Angle For beam diameter at any distance, multiply distance by 0.21 50% .059 .118 .176 .235 15.0’ 4.6m 20.0’ 6.1m 25.0 7.6m Field Diameter 3.5’ 1.1m 5.2’ 1.6m 6.9’ 2.1m 8.6’ 2.6m Illuminance (fc) 1,243 552 311 199 Illuminance (lux) 13,380 5,946 3,345 2,141 Candela Plot 140000 120000 Candela Throw Distance (d) 10.0’ 3.0m 100000 80000 X Y 60000 40000 20000 0 -15 -10 -5 0 Degrees 3 of 6 5 10 15 ETC® Fresnel Series LAMPS To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor (CdMF or LmMF) shown for that lamp in the table below. ETC Avg. Rated Life Spot Spot Flood Flood Cd MF Lm MF Cd MF Lm MF 3,250 300 1.00 1.00 1.00 1.00 3,050 1,500 Watts Volts Initial Lumens Color Temp. K HPL 750/115** 750 115 21,900 HPL 750/115X 750 115 16,400 RT113 HPL 575/115** 575 115 16,520 3,250 300 RT114 HPL 575/115X 575 115 12,360 3,050 2,000 RT142 HPL 375/115 375 115 10,540 3,250 300 RT143 HPL 375/115X 375 115 8,500 3,050 1,000 N/A HPL 750/120 750 120 21,900 3,250 300 N/A HPL 750/120X 750 120 16,400 3,050 1,500 RT115 HPL 575/120 575 120 16,520 3,250 300 RT171 HPL 575/120X 575 120 12,360 3,050 2,000 RT112 HPL 550/77* 550 77 16,170 3,250 300 RT117 HPL 550/77X* 550 77 12,160 3,050 2,000 RT160 HPL 750/230** 750 230 19,750 3,200 300 N/A HPL 750/230X 750 230 15,600 3,050 1,500 Part # Lamp Code RT116 RT196 RT129 HPL 575/230** 575 230 14,900 3,200 400 RT138 HPL 575/230X 575 230 11,780 3,050 1,500 RT154 HPL 375/230X 375 230 7,800 3,050 1,000 N/A HPL 750/240 750 240 19,750 3,200 300 N/A 1,500 HPL 750/240X 750 240 15,600 3,050 RT130 HPL 575/240 575 240 14,900 3,200 400 RT139 HPL 575/240X 575 240 11,780 3,050 1,500 RT155 HPL 375/240X 375 240 7,800 3,050 1,000 N O O S G IN M O C .78 .86 .81 .84 N O O S G IN M O C Source Four Fresnels rated for 750W maximum. *77 Volt HPL lamps are for use with ETC Dimmer Doubling™ technlology only. **Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying factors extrapolated from primary test data. For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com. HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K “N/A” lamps are not available for purchase from ETC. Contact your dealer for purchase. 4 of 6 ETC® Fresnel Series O R D E R I N G I N F O R M AT I O N PHYSICAL Continued from front page... Source Four Fresnel Accessories 19.6” 497mm 15.0” 381mm 12.8” 325.6mm 6.9” 176mm MODEL DESCRIPTION 407CF Color frame (7.5”) (included) 400SC Safety Cable 400CC C-Clamp 400BD Barn Door 400PTH3 Top hat, 3” 400PTH6 Top hat, 6” 400PHH Half hat 400PGE3 Gel extender, 3” 400PGE6 Gel extender, 6” 400WB Weighted base 400XBTH Cross baffle top hat 400L Egg crate louver Note: For colors other than black and white, please call ETC. 6.5” 165mm 8.6” 218.9mm 9.43” 239.5mm Source Four products are protected by one or more of the following patents: 10.9” 278.4mm U.S. USRE36,3316, US5,345,371, US6,092,914 and US5,775,799 U.K. GB0592589, GB0673488, 99930527.9* Germany DE0592589, GB0673488, 99930527.9* Japan JP2,501,772 * European patent application number 9.1” 13.5” 341.6mm 5.64” 229.9mm 143.3mm 7.32” 186mm 12.4” 315mm Source Four Fresnel Weights* MODEL Fresnel WEIGHT SHIPPING WEIGHT lbs kgs lbs kgs 13.3 6.1 17.5 8.0 *Add 2.3 lbs for C-clamp 5 of 6 ETC® Fresnel Series Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0)20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2011 ETC. All Rights Reserved. All product information and specifications subject to change. 7064L1001 Rev. A Printed in USA 3/11 6 of 6 ETC® Source Four® jr 26° Ellipsoidal Series S p e c i f i c at i o n s S p e c i f i c at i o n s PHYSICAL • Rugged die cast aluminum construction • 20 gauge stainless steel shutters in a bi-plane assembly • Interchangeable lens tubes with smooth–running teflon guides provide three user-fit field angle options • High impact, thermally insulated knobs and shutter handles • Two accessory slots, and a top mounted, gel frame retainer • Steel yoke with two mounting positions • Positive locking, hand-operated yoke clutch • Slot for stainless steel patterns • Slot with sliding cover for motorized pattern devices or optional iris • UL and cUL Listed ELECTRICAL • 115-240V, 50/60Hz • High temperature 3–conductor 36” leads in a glass fiber outer sleeve • Supports ETC Dimmer Doubling™ technology LAMP • HPL — compact tungsten filament contained in a kryptonfilled quartz envelope (see table for suitable lamp types) • 575W Maximum • Integral die cast aluminum heat sink lamp base OPTICAL • Optimized optical system for efficient photometric performance • Projector-quality, high contrast aspheric lens • Faceted borosilicate reflector with dichroic cold mirror coating removes greater than 90% infrared radiation (heat) and reflects greater than 95% of visible light • Reflector secured with anti-vibration shock mounts • Tool free, positive locking X, Y and Z lamp centering adjustments, unaffected by relamping • Beam edge continually adjustable hard-to-soft • Interchangeable lens assembly kits permit selection of 26°, 36°, and 50° field angles, and 25°-50° zoom range Ord e r i n g i n f o rm a t i o n Source Four jr Model Description 426J 26˚ Source Four jr ellipsoidal (black) 426J-1 26˚ Source Four jr ellipsoidal (white) ETC Source Four jrs are supplied with C-clamp, color frame and 3’ (96cm) leads as standard Connector Designation Use Suffixes below to specify Factory–Fitted Connector type Model Description A Parallel-blade U-ground connector B Two-pin and ground, 20 amp connector C Grounded, 20 amp, twistlock connector M Dimmer Doubling Connector (NEMA L515P) See back page for Source Four jr Accessories 1 of 4 ETC® Source Four® jr 26° Ellipsoidal Series photometrics 25˚ Field Angle 20˚ Beam Angle Photometric data below is measured with an HPL 575W/115V 300 hr lamp. To convert data when using any other HPL lamp, use the lumen or candela multiplying factors (Lm MF or Cd MF) for that specific lamp. These multiplying factors are listed in the Lamps table in this datasheet. For lumen data, multiply by the Lm MF. For candela or footcandle data, multiply by the Cd MF. Source Four jr 26˚(cosine) Throw Distance (d) 20’ 6.1m 30’ 9.1m 35’ 10.7m 45’ 13.7m Field Diameter 8.9’ 2.7m 13.3’ 4.1m 15.5’ 4.7m 20’ 6.1m Degree Candela Field Lumens Beam Lumens Efficiency Lumens per watt Illuminance (fc) 229 102 75 45 26˚ 91,480 7,795 5,913 47.2% 13.6 2,462 1,094 804 486 Illuminance (lux) Metric Conversions: For Meters multiply feet by .3048 For Lux multiply footcandles by 10.76 For illumination with any lamp, multiply the candlepower of a beam spread by the multiplying factor (mf) shown for that lamp. To determine illumination in footcandles or lux at any throw distance, divide candlepower by distance squared. For Field diameter at any distance, multiply distance by 0.44 For Beam diameter at any distance, multiply distance by 0.35 Iso-Illuminance Diagram Cosine Candela Plot Y 120000 10% 100000 Candela 80000 X X 60000 Y 40000 20000 50% 0 -15 -12 -9 -6 -3 0 Degrees Complete IES photometry data files (LM-63-02 format) may be downloaded from the ETC website. Go to http://www.etcconnect.com/downloads.asp 2 of 4 3 6 9 12 15 ETC® Source Four® jr 26° Ellipsoidal Series Lamps To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor (CdMF or LmMF) shown for that lamp in the table below. ETC Part # Lamp Code Watts Volts Initial Lumens Color Temp. K Average Rated Life 26° 26° Cd MF Lm MF 1.00 1.00 RT113 HPL 575/115** 575 115 16,520 3,250 300 RT114 HPL 575/115X 575 115 12,360 3,050 2,000 .64 .71 RT142 HPL 375/115 375 115 10,540 3,250 300 .84 .64 RT143 HPL 375/115X 375 115 8,500 3,050 1,000 .58 .48 RT115 HPL 575/120 575 120 16,520 3,250 300 1.00 1.00 RT171 HPL 575/120X 575 120 12,360 3,050 2,000 .64 .71 RT112 HPL 550/77* 550 77 16,170 3,250 300 1.02 .98 RT117 HPL 550/77X* 550 77 12,160 3,050 2,000 .66 .73 RT129 HPL 575/230** 575 230 14,900 3,200 400 .68 .63 RT138 HPL 575/230X 575 230 11,780 3,050 1,500 .44 .45 RT154 HPL 375/230X 375 230 7,800 3,050 1,000 .38 .33 RT130 HPL 575/240 575 240 14,900 3,200 400 .65 .63 RT139 HPL 575/240X 575 240 11,780 3,050 1,500 .41 .44 RT155 HPL 375/240X 375 240 7,800 3,050 1,000 .38 .33 Source Four jr is rated for 575W maximum. *77 Volt HPL lamps are for use with ETC Dimmer Doubling technlology only. **Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying factors extrapolated from primary test data. For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com. HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K 3 of 4 ETC® Source Four® jr 26° Ellipsoidal Series p hys i c a l Ord e r i n g i n f o rm a t i o n Continued from front page... Source Four jr Accessories 13.7”/ 348mm max 10.6”/ 269mm min 8.8”/ 224mm max 6.1”/155 mm min 6.9” 175mm 19.3” 490mm Model Description 450JL 50˚ jr lens assembly 436JL 36˚ jr lens assembly 426JL 26˚ jr lens assembly 400JZK Source Four jr Zoom upgrade kit* 400CC C–clamp (included) 400SC Safety cable 400JRS Drop-in iris 400CF Colorframe (6.25”) (included) 400DN Donut (6.25”) 400TH Top hat 400HH Half hat 400GE Gel extender 400PH-M Pattern Holder (M size) Note: For colors other than black and white, please call ETC. * Converts any Source Four jr to a Source Four jr Zoom 18.5” 470mm Source Four products are protected by one or more of the following patents: U.S. 7.0” 178mm 9.7” 246mm USRE36,3316, US5,345,371, US6,092,914 and US5,775,799 U.K. GB0592589, GB0673488, 99930527.9* Germany DE0592589, GB0673488, 99930527.9* Japan JP2,501,772 * European patent application number Source Four jr Weights* model 426j weight shipping weight lbs kgs lbs kgs 10 4.5 16.5 7.5 *Includes 2.3 lbs for C-clamp Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0)20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7062L1007 Rev. F Printed in USA 12/10 4 of 4 ETC® Source Four® 26˚ Ellipsoidal Series S P E C I F I C AT I O N s S P E C I F I C AT I O N s physical • Rugged, die cast aluminum construction • Rotating shutter assembly ±25˚ • 20 gauge stainless steel shutters in a tri-plane assembly • Interchangeable lens tubes with smooth-running teflon guides provide nine user-fit field angle options • Thermally insulated rear handle • High impact, thermally insulated knobs and shutter handles • Two accessory slots and a top mounted, gel frame retainer • Steel yoke with two mounting positions • Positive locking single-clutch fixture body • Slot for glass or stainless steel patterns • Wide accessory slot with sliding cover for motorized pattern devices or optional iris • UL and cUL Listed ELECTRICAL • 115-240V, 50/60Hz • High temperature 3-conductor 36” leads in a glass fiber outer sleeve • Supports ETC Dimmer Doubling™ technology LAMP • 750W maximum • HPL – compact tungsten filament contained in a kryptonfilled quartz envelope (see table for available lamp options) • Patented filament geometry makes for extremely efficient light collection and transmission • Integral die cast aluminum heat sink lamp base OPTICAL • Re-optimized optical system for improved photometric performance and field uniformity • Projector-quality, high contrast aspheric lens • Optional enhanced definition lens tube available for even higher image quality • Faceted borosilicate reflector with dichroic cold mirror coating removes greater than 90% infrared radiation (heat) and reflects greater than 95% of visible light • Reflector secured with anti-vibration shock mounts • Lens(es) secured with anti-vibration shock mounts • Tool free, positive locking X, Y and Z lamp centering adjustments, unaffected by relamping • Beam edge continually adjustable hard-to-soft • Interchangeable lens barrels permit selection of 5˚, 10˚, 14°, 19˚, 26˚, 36˚, 50˚, 70°, and 90° field angles as well as 19˚, 26˚, 36˚, and 50˚ EDLT lenses O rderin g infor m ation Source Four Model Description 426 26˚ ellipsoidal (black) 426-1 26˚ ellipsoidal (white) ETC Source Four are supplied with C-clamp, color frame and 3’ (96cm) leads as standard Connector Designation Use Suffixes below to specify Factory–Fitted Connector type Model Description -A Parallel-blade U-ground connector -B Two-pin and ground, 20 amp connector -C Grounded, 20 amp, twistlock connector -M Dimmer Doubling Connector (NEMA L515P) See back page for Source Four Accessories 1 of 4 ETC® Source Four® 26˚ Ellipsoidal Series photo m etrics 25˚ Field Angle 18˚ Beam Angle Photometric data below is measured with an HPL 750W/115V 300 hr lamp. To convert data when using any other HPL lamp, use the lumen or candela multiplying factors (Lm MF or Cd MF) for that specific lamp, listed in the Lamps table in this datasheet. For lumen data, multiply by the Lm MF. For candela or footcandle data, multiply by the Cd MF. Throw Distance (d) 15’ 4.6m 30’ 9.1m 45’ 13.7m 60’ 18.1m Field Diameter 6.7’ 2.0m 13.4’ 4.1m 20.1’ 6.1m 26.8’ 8.2m Illuminance (fc) 783 196 87 49 8,432 2,108 937 527 Illuminance (lux) Source Four 26˚(cosine) Degree Candela Field Lumens Beam Lumens Efficiency Lumens per watt 26˚ 176,255 13,690 9,040 62.5% 18.3 Metric Conversions: For meters, multiply feet by .3048 For Lux multiply footcandles by 10.76 To determine center beam illumination in footcandles at any throw distance, divide candela by the throw distance squared. For Field diameter at any throw distance, multiply the throw distance by .45 For Beam diameter at any throw distance, multiply the throw distance by .32 Iso-Illuminance Diagram (Flat Surface Distribution) Cosine Candela Plot Y 200000 10% 180000 50% X 140000 Candela % illuminance foot candle or lux 160000 120000 X Y 100000 80000 60000 40000 20000 0 -15 -12 -9 -6 -3 0 Degrees Degrees Complete IES photometry data files (LM-63-02 format) may be downloaded from the ETC website. Go to http://www.etcconnect.com/downloads.asp 2 of 4 3 6 9 12 15 ETC® Source Four® 26˚ Ellipsoidal Series L a m ps To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor (CdMF or LmMF) shown for that lamp in the table below. Color Temp. K Average Rated Life 26° 26° ETC Part # Lamp Code Watts Volts Initial Lumens Cd MF Lm MF RT116 HPL 750/115** 750 115 21,900 3,250 300 1.00 1.00 RT196 HPL 750/115X 750 115 16,400 3,050 1,500 .64 .74 RT113 HPL 575/115** 575 115 16,520 3,250 300 .78 .82 RT114 HPL 575/115X 575 115 12,360 3,050 2,000 .56 .56 RT142 HPL 375/115 375 115 10,540 3,250 300 .66 .52 RT143 HPL 375/115X 375 115 8,500 3,050 1,000 .45 .40 N/A HPL 750/120 750 120 21,900 3,250 300 1.00 1.00 N/A HPL 750/120X 750 120 16,400 3,050 1,500 .64 .74 RT115 HPL 575/120 575 120 16,520 3,250 300 .78 .82 RT171 HPL 575/120X 575 120 12,360 3,050 2,000 .56 .56 RT112 HPL 550/77* 550 77 16,170 3,250 300 .77 .77 RT117 HPL 550/77X* 550 77 12,160 3,050 2,000 .59 .56 RT160 HPL 750/230** 750 230 19,750 3,200 300 .64 .75 N/A HPL 750/230X 750 230 15,600 3,050 1,500 .40 .59 RT129 HPL 575/230** 575 230 14,900 3,200 400 .53 .61 RT138 HPL 575/230X 575 230 11,780 3,050 1,500 .38 .45 RT154 HPL 375/230X 375 230 7,800 3,050 1,000 .29 .32 N/A HPL 750/240 750 240 19,750 3,200 300 .64 .75 N/A HPL 750/240X 750 240 15,600 3,050 1,500 .40 .59 RT130 HPL 575/240 575 240 14,900 3,200 400 .50 .61 RT139 HPL 575/240X 575 240 11,780 3,050 1,500 .36 .45 RT155 HPL 375/240X 375 240 7,800 3,050 1,000 .29 .32 Source Four is rated for 750W maximum *77 Volt HPL lamps are for use with ETC Dimmer Doubling technology only **Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying factors extrapolated from primary test data. For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K “N/A” lamps are not available for purchase from ETC. Contact your Dealer for purchase. 3 of 4 ETC® Source Four® 26˚ Ellipsoidal Series physical O rderin g infor m ation Continued from front page... ETC Source Four Accessories 14.9”/ 378mm max. 11.8”/ 300mm min. 10.0”/ 254mm max. 7.3”/ 185mm min. 8.5” 216mm 20.1” 511mm 22.8” 579mm 21.3” 541mm Model Description 426LT 26˚ lens tube complete (black) 426LT-1 26˚ lens tube complete (white) 426EDLT 26° Enhanced Definition Lens Tube complete (black) 426EDLT-1 26° Enhanced Definition Lens Tube complete (white) 400CC C–clamp (included) 400PH-A Pattern holder (A size) 400PH-B Pattern holder (B size) 400PH-G Glass pattern holder 400SC Safety cable 400RS Drop-in iris 400CF Colorframe (6.25”) (included) 400DN Donut (6.25”) 400TH Top hat 400HH Half hat 400GE Gel extender (Recommended for 19° and 26° only) 407GE Conical gel extender (requires 407CF below) 407CF 7.5” Square color frame (required for 14°, 70°, 90° and 407GE) 400FB Source Four fixture body, single clutch Note: For colors other than black or white, please call ETC. 6.8” 173mm 13.3” 338mm Source Four Weights* model weight 26˚ Source Four products are protected by one or more of the following patents: shipping weight lbs kgs lbs kgs 14 6.4 20 9.1 *Includes 2.3 lbs for C-clamp U.S. USRE36,3316, US5,345,371, US6,092,914 and US5,775,799 U.K. GB0592589, GB0673488, 99930527.9* Germany DE0592589, GB0673488, 99930527.9* Japan JP2,501,772 * European patent application number Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0)20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7060L1008 Rev. G Printed in USA 12/10 4 of 4 ETC® Sensor®+ Racks Sensor+ Series O r d e r i n g i n f o r m at i o n Installation Racks Model Description SR48+ Sensor+ 48 Module Rack SR24+ Sensor+ 24 Module Rack SR12+ Sensor+ 12 Module Rack SR6+ Sensor+ 6 Module Rack SR24+1P Sensor+ 24 Module Single Phase Rack SR12+1P Sensor+ 12 Module Single Phase Rack SR6+1P Sensor+ 6 Module Single Phase Rack Rack Options* Model Description AT48 Amp-Trap fuse option for 48-module rack AT24 Amp-Trap fuse option for 24-module rack AT12 Amp-Trap fuse option for 12-module rack G e n e r a l I n f o r m at i o n BK48 Bussing kit for 2 – 48-module racks Sensor+ dimming systems provide high density, professional features and exceptional reliability for lighting applications that require the best the entertainment industry can offer. BK24 Bussing kit for 2 – 24-module racks BK12 Bussing kit for 2 – 12-module racks AUX30-48 30” Auxiliary Rack(s) for 48-module rack APPLICATIONS • Professional and educational theatre • Production studios • Concert and performance halls • Themed retail and dining • Multi-use Convention Centers • Houses of Worship FEATURES • High dimmer density • Up to two 2.4kW dimmers per module • 6, 12, 24, and 48 module racks available • Rugged industrial construction • Installation flexibility • Adaptable modular design • 100,000A Short Circuit Current Rating (SCCR) • Advanced configuration editing built into rack • Stores up to 128 Presets in memory • Direct Ethernet control signal input • Two DMX512 inputs • Standard system and rack monitoring with diagnostic reporting • Supports ETC Dimmer Doubling™ • All racks UL and cUL LISTED ACCESSORIES • SmartLink® Button Stations and SmartLink TimeClock • Dimmer Doubler • Sound Suppression Hood • Floor pedestal for 24-module rack • Document holder AUX19-48 19” Auxiliary Rack(s) for 48-module rack AUX19-24 19” Auxiliary Rack(s) for 24-module rack AUX19-12 19” Auxiliary Rack(s) for 12-module rack Vibration Reduction mounts available for all Sensor+ racks. Contact ETC for details Note: Power feeds above 800A up to 2000A require addition of a 30” auxiliary rack. * Rack Accessories Model Description SSSh24-48 Sensor+ Sound Suppression Hood – large SSSh6-12 Sensor+ Sound Suppression Hood – small Pedestal Floor pedestal for 24-module rack DH Document Holder SmartLink Accessories Model Description S-LPB SmartLink Power Board for Sensor+ Racks* S-10005 SmartLink 5-Button Station* S-10010 SmartLink 10-Button Station* *One SmartLink Power Board required for station support. S-LPB supports up to four stations. Only one S-LPB may be enabled in a system. 1 of 4 ETC® Sensor®+ Racks Sensor+ Series sp e ci f ic a t i o n s Addi t i o n a l I n f o r m a t i o n GENERAL • Racks available in four sizes -- SR6+ 6 modules, 12 dimmers maximum -- SR12+ 12 modules, 24 dimmers maximum -- SR24+ 24 modules, 48 dimmers maximum -- SR48+ 48 modules, 96 dimmers maximum • Dual density (two dimmers per module), single density and half density dimmer modules available • Operating temperature: 0-40°C / 32-104°F -- Dimmer room HVAC systems must at all times maintain the specified ambient temperature at the dimmer rack. Dimming systems operating within 10 degrees F of the upper or lower temperature limits must strictly follow installation and operation guidelines to operate reliably. • Relative humidity: 30-90% non-condensing • All racks UL and cUL LISTED • UL924 LISTED for Bypass operation MECHANICAL • Rugged 16-gauge steel construction • Fine-textured, scratch-resistant, epoxy paint • SR6+ and SR12+ uses wall mount installation • SR24+ can be wall or pedestal mounted • SR48+ is floor mounted • Top and bottom conduit access through removable panels (SR48+) or knockouts (SR6+, SR12+, and SR24+) • No tools required for module removal or installation • Keyed module slots prevent insertion of inappropriate module types • Front access to all wiring and terminations • Full height locking door • Electrostatic air filter easily removed from door for periodic cleaning • High efficiency cooling system with airflow sensor • High visibility LED status beacon ELECTRICAL • SR6+, SR12+ and SR24+ accept: -- Three phase 120/208 VAC -- Single phase 120/240 VAC • SR48+ accepts -- Three phase 120/208 VAC • Line feed frequencies from 47-63Hz • Line feed voltage range is 91-139 VAC* • Load terminals accept up to #4 AWG (16mm2) wire (see chart) • S hort Circuit Current Rating: 100.000A RMS symmetrical @ 240VAC • Auxiliary equipment racks and custom switchgear/distribution available (Call ETC for details) *Note:Suggested max main transformer tap 135V to allow for line fluxuation. CONTROL Electronics • Sensor+ Control Electronics Module (CEM+) • Single Ethernet control signal input • Two DMX512 inputs • S tandard diagnostic reporting via browser-based interface or DimStat software • Supports Dimmer Doubling™ • Supports SmartLink® control of presets OPTIONS • Advanced Features™ dimmer-specific load and diagnostic reporting • Amp-Trap® fuses to allow feeding individual racks from oversize mains • Bus kits available • Vibration reduction kits available for all racks • SmartLink Power Board • SmartLink TimeClock Compatible Dimmer Modules Sensor Standard Modules Model Description D15/D20 Dual 15A/20A Dimmer Module – 350μS D15E/D20E Dual 15A/20A Dimmer Module – 500μS D50AF Single 50A Dimmer Module – 500μS – AF D100AF* Half 100A Dimmer Module – 500μS – AF Sensor Special purpose Modules L10 Dual 10A Low Wattage Dimmer Module L10F Single 10A Low Wattage Fluorescent Dimmer Module D15F/D20F Single 15A/20A Fluorescent Dimmer Module R15/R20 Dual 15A/20A Relay Module CC15/CC20 Dual 15A/20A Constant Circuit Breaker Module AFM Air Flow Module *Half-density modules use two module slots Control Modules Model Description CEM+ Control Electronics Module + Load Wiring Lug Capacity Connection WIre Size 10A, 15A, 20A, and 50A lugs 4 AWG Max. (16mm2) 100A lugs 2/0 Max. Primary Feed Lug Capacity Connection WIre Size SR48+ Dual 600 kcmil – 2 AWG SR24+ Dual 350 kcmil – 4 AWG SR12+ Dual 250 kcmil – 6 AWG SR6+ Single 2/0 – 14 AWG Sound Pressure Level (dBA) MODEL dBA @ 1000Hz (1kHz)* WITHOUT WITH SSSh** SR48+ 37.0 30.9 SR24+ 40.2 34.0 SR12+ 41.8 33.8 SR6+ 26.0 21.4 *dBA values for each Sensor rack measured at 1 meter. Visit www.etcconnect.com for full spectrum dBA ratings. **Sensor Sound Supression Hood (SSSh) 2 of 4 ETC® Sensor®+ Racks Sensor+ Series t y pic a l s y s t e m r is e r Switch DMX Plug-in DMX Booth DMX Plug-in DMX SmartLink Stage Preset 1 Preset 2 Preset 3 Preset 6 Preset 7 Preset 8 Preset 1 Preset 4 Preset 9 Preset 5 Preset 10 Preset 2 Preset 3 Preset 1 Preset 6 Preset 4 Preset 2 Preset 7 Preset 5 Preset 3 Preset 8 Preset 1 Preset 4 Preset 9 Preset 5 Preset 10 Preset 2 Preset 3 Preset 4 Preset 5 Congo jr Console Sensor+ Dimming System T y pic a l n e t w o r k r is e r Link Power Aux Power Unison Control Stations Link Power PC for ETC software CMEi in ER4 Rack Switch Radio Focus Remote (Transmitter) Eos Remote Video Interface Eos Console DMX Net3 DMX Gateway Net3 DMX Gateway DMX from external source Sensor+ Dimming System Radio Focus Remote (Receiver) 3 of 4 To moving lights or any DMX device ETC® Sensor®+ Racks Sensor+ Series ph y sic a l Empty Dimmer Rack Weights model weight shipping weight lbs kgs lbs kgs 188 86 198 90 SR48+ Door 31 14 35 SR24+ 107 49 115 * 17 8 20 SR12+ 45 21 50 23 SR12+ Door* 11 5 14 6.5 SR6+ with Door 36 16 45 21 SR48+ * SR24+ Door Installation Rack Dimensions Model Height Width Depth inches mm inches mm inches mm SR48+ 83.1 2110 14.6 370 22.8 580 16 SR24+ 45.8 1160 14.6 370 16.8 430 53 SR12+ 25.8 660 14.6 370 13.3 340 9 SR6+ 16.4 420 14.6 370 13.3 340 Rack doors ship separately * SR48+ Full Dimmer Rack Weights model Max. weight Typical weight lbs kgs lbs kgs SR48+ 493 224 459 209 SR24+ 261 119 244 111 SR12+ 115 53 105 48 SR6+ 71 33 66 30 Maximum – D100AF modules (11.7lbs/slot) * All racks require minimum clearance above fan 10.0” 250mm 83.1” 2110mm SR24+ Typical – D20 modules (5lbs/slot) Refer to module datasheets to calculate rack weight for other module types 45.8” 1160mm SR12+ 25.8” 660mm SR6+ 16.4” 420mm Wall or other barrier (all racks) 14.6” 370mm 14.6” 370mm 13.3” 340mm 6” 150mm 13.3” 340mm 17” 460mm 17” 460mm 14.6” 370mm 14.6” 370mm 6” 150mm 6” 150mm 16.8” 430mm 22.8” 580mm 17” 460mm 6” 150mm 17” 460mm Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Pieve Torina, 48, 00156 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7151L1001 Rev. G Printed in USA 10/10 Sensor® products protected by one or more of the following U.S. Patent Numbers 5,323,088, 5,352,088, 7,233,112, 7,019,469, 6,849,943, and 6,002,563; European Number 0603333T2; German 69203609. 4 of 4 ETC Standard Dimmer Module Standard Series nal Sig D20 nal Sig G e n e r a l I n f o r m at i o n O r d e r i n g i n f o r m at i o n The Standard Dimmer Module is designed for use in both Sensor®+ and Unison® Dimming Series modular rack enclosures. Standard Dimmer Modules provide cost-effective digital forward phase angle dimming for standard loads such as incandescent, low voltage, quartz, neon, cold-cathode and 2 and 4-wire fluorescent ballasts. The patented, high-density, dual modules feature modular installation and removal, fully magnetic circuit breakers and standard or enhanced risetime toroidal filters. 100-120V Standard Dimmer Modules APPLICATIONS • Incandescent lighting • Low voltage lighting • Quartz lighting • Neon lighting • Cold Cathode lighting • 2-wire Fluorescent ballast • 4-wire Fluorescent ballast FEATURES • Two 1.8 or 2.4kW dimmers per module • Standard or Enhanced risetime toroidal filters • High-density modular assembly • Die-cast aluminum chassis • Fully magnetic circuit breakers General • 100,000A Short Circuit Current Rating (SCCR) • UL and cUL LISTED Model Description D15 Dual 15A Dimmer Module, 350μS D15E Dual 15A Dimmer Module, 500μS D20 Dual 20A Dimmer Module, 350μS D20E Dual 20A Dimmer Module, 500μS AFM Air Flow Module Compatible Systems Model Description Sensor+ Installation Racks* SR6+ Sensor+ 6 module rack SR12+ Sensor+ 12 module rack SR24+ Sensor+ 24 module rack SR48+ Sensor+ 48 module rack SR6AF+ Sensor+ 6 module Advanced Features rack SR12AF+ Sensor+ 12 module Advanced Features rack SR24AF+ Sensor+ 24 module Advanced Features rack SR48AF+ Sensor+ 48 module Advanced Features rack SRAFN+ Sensor+ GFCI racks Sensor+ Touring Racks SP4820+ Sensor+ 24 module Touring Rack (48-20A dimmers) SP9620+ Sensor+ 48 module Touring Rack (96-20A dimmers) Sensor+ Portable Packs SP1220+ Sensor+ 6 module Portable Pack (12-20A dimmers) SP1215+ Sensor+ 6 module Portable Pack (12-15A dimmers) SP2420+ Sensor+ 12 module Portable Pack (24-20A dimmers) SP2415+ Sensor+ 12 module Portable Pack (24-15A dimmers) Rack enclosures also available for 230CE and 240 Volt applications * 1 of 2 ETC Standard Dimmer Module Standard Series sp e ci f ic a t i o n s physical GENERAL • UL and cUL Listed for continuous duty at 100% of rated load -- D15/D15E – 1.8kW -- D20/D20E – 2.4kW PHYSICAL • Modular plug-in assemblies • Cast aluminum chassis, finished with textured epoxy paint • Keyed to prevent insertion in inappropriately rated rack positions CIRCUIT BREAKERS • Fully magnetic to eliminate nuisance tripping • 20x inrush current rating • 125%, 10-120 seconds, must-trip rating • Rated for 100% switching duty applications RATINGS • 100,000A Short Circuit Current Rating Rating (SCCR) • Modules withstand hot-patching of cold loads up to full rating • UL and cUL LISTED Power Device • Sealed, patented assembly • Field replaceable with screwdriver • Two back-to-back SCRs per circuit • One control LED per circuit • 4000V isolation between control and power components • Integral bonded heatsink • Integral temperature sensor FILTERING • High quality toroidal filters -- 350μS risetime - Standard 100-120V modules* -- 500μS risetime - Enhanced 100-120V modules* Module Dimensions *Risetime measured at full load, at worst case firing angle (90 degrees), from 1090% of output wave form Dimmer room HVAC systems must at all times maintain the specified ambient temperature at the dimmer rack. Dimming systems operating within 10°F of the upper or lower temperature limits must strictly follow installation and operation guidelines to operate reliably. Model Height Width Depth inches mm inches mm inches mm D15 1.5 38. 11.8 300 4.9 127 D15E 1.5 38 11.8 300 4.9 127 D20 1.5 38 11.8 300 4.9 127 D20E 1.5 38 11.8 300 4.9 127 Module Weights model weight lbs shipping weight kgs lbs kgs D15/D20 5.0 2.3 6.9 3.1 D15E/D20E 5.5 2.5 6.9 3.1 Maximum BTU Production per module model BTUs Watts Efficiency D15 380 112 96.9% D15E 474 140 96.1% D20 522 154 96.8% D20E 810 238 95.0% These values should be provided to a qualified HVAC design engineer, along with dimmer quantities, types and dimmer room dimensions, to calculate dimmer room air handling requirements. DIMMER RANGE • Incandescent, low voltage dimming range 100-0% • Dimming range of 2 and 4-wire fluorescent ballast is dependent on lamp ballast combination. Contact ETC for range verification • Sizing of Neon transformer used in dimming applications should be 1.5x greater than size used in non-dimming application SCR Rating moDULE Single cycle peak surge current Half cycle peak surge current Transient over voltage D15/D20 625A 1620A 600V Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. 7050L1028 Rev. D Printed in USA 10/08 Sensor® products protected by one or more of the following U.S. Patent Numbers 5,323,088, 5,352,088, 7,233,112, 7,019,469, 6,849,943, and 6,002,563; European Number 0603333; German 69203609. 2 of 2 ETC Unison® Heritage™ Button Station Unison Control Series O r d e r i n g i n f o r m at i o n Button Stations G e n e r a l I n f o r m at i o n Elegant and clean-lined, Unison Heritage controls are designed to complement – not to compete with – the aesthetics of any interior environment, while being easy to install using LinkConnect. Artful but durable, Heritage stations are engineered to stand up to the daily abuse of busy public areas. The Unison Heritage series of button control stations can be customized to suit any décor and application – available in a wide range of sizes, colors and configurations. Choose from pre-configured button combinations or put stations together to create endless combinations of controls. APPLICATIONS • Churches • Hotels • Convention Centers • Meeting Rooms • Schools • Restaurants FEATURES • LinkConnect – using Echelon’s LonTalk® protocol with LinkPower, the two wire topology-free system gives you the freedom to put stations where you need them • Fastener Free Faceplate System – no visible means of attachment • ColorCondition – RGB LED’s allow for customized control indication on a per button basis, unlocking the conditional logic capabilities of a Paradigm control system • Forever Legend System – complimentary colored standard or custom legend options using an indelible, laser-marking method • RemoteDirect – a built in InfraRed (IR) receiver on every station allows for optional IR remote control at every station • LockOut – configurable control lockout from the push of a button • Take Control – set the faders on a Heritage fader station and then choose when to gain control of the lighting in a room, at exactly the right moment model description Legend UH00001- __1F 1/2 gang, 1 button On/Off UH00002- __1F 1/2 gang, 2 button On, Off UH00005- __1F 1/2 gang, 5 button Preset 1-4, Off UH10001- __1F 1 gang, 1 button On/Off UH10001- __2F 1 gang, 1 button Entry UH10001- __3F 1 gang, 1 button Panic UH10002- __1F 1 gang, 2 button On, Off UH10002- __2F 1 gang, 2 button Open, Close UH10005- __1F 1 gang, 5 button Preset 1-4, Off UH10007- __1F 1 gang, 7 button Raise, Lower, Preset 1-4, Off UH10010- __1F 1 gang, 10 button Preset 1-9, Off UH11K00- __1F 1 gang, 1 keyswitch (maintained*) Lockout UH11K01- __1F 1 gang, 1 keyswitch (maintained*), 1 button Lockout, On/Off UH11K01- __2F 1 gang, 1 keyswitch (maintained*), 1 button Lockout, Entry UH11K01- __2F 1 gang, 1 keyswitch (maintained*), 1 button Lockout, Panic UH11K02- __1F 1 gang, 1 keyswitch (maintained*), 2 button Lockout, On, Off UH11K02- __2F 1 gang, 1 keyswitch (maintained*), 2 button Lockout, Open, Close UH11K05- __1F 1 gang, 1 keyswitch (maintained*), 5 button Lockout, Preset 1-4, Off *Keyswitch stations available in momentary configurations. Notes: Enter station color code in __ space provided: 1 = Cream (RAL 9001) 2 = Ivory (RAL 1015) 3 = Gray (RAL 7001) 4 = Black (RAL 9004) 5 = Signal White (RAL 9003) Above stations flush mount (F) in industry standard gang boxes. (By Others) Also available in surface mount (S) and portable (P) configurations. (Contact ETC) 1 of 2 ETC Unison® Heritage™ Button Station Unison Control Series sp e ci f ic a t i o n s physical GENERAL • UL and cUL LISTED • CE Marked FUNCTIONAL • Button and keyswitch functions include: preset selection, record mode activation, station lockout, raise, lower, macro activation, zone on/off control, timed event override and wall open/close or toggle • Custom button functionality programmable via LightDesigner configuration software • Programmable electronic lockout levels • Allows for programming of individual lockout levels MECHANICAL • Standard configurations with 1, 2, 5, 7 and 10 buttons or 0,1,2,and 5 buttons with a maintained or momentary keyswitch • Custom button stations available, contact ETC • Gangable for custom applications • Enclosed electronics assembly and faceplate included • Cantilevered switch arrays with removable caps • No visible means of attachment • Flush mount in industry standard back box, RACO 690 or equivalent • Surface mount back-boxes available from manufacturer • Constructed of injection molded, ABS plastic in five standard colors, matched to RAL standard colors • Custom colors available with sample • Indelibly marked legends in a contrasting color • Integral RGB LED response indicator for each button • Integrated IR receiver ELECTRICAL • Connect via Echelon® LinkPower control network utilizing low voltage Class II wiring • Topology free and polarity independent wiring over Belden 8471 or equivalent and (1) #14 ESD drain wire • Wiring may be bus, loop, home-run or any combination of these • All station terminations are connectorized • UL and cUL LISTED, CE marked THERMAL • Ambient room temperature: 0-40°C / 32-104°F • Ambient humidity: 30-90% non-condensing Flush Backbox Dimensions* Gang Height Width Depth inches mm inches mm inches mm 1/2 3.75 95.3 1.3 33 3.25 82.6 1 3.75 95.3 2.0 50.8 2.5 63.5 1 Gang flush mount back box RACO 690 1/2 Gang flush mount back box provided by ETC Surface Backbox Dimensions* gang Height inches Width mm inches Depth mm inches mm 1/2 3.75 95.3 1.75 44.5 3.25 82.6 1 3.75 95.3 2.0 50.8 2.5 63.5 Surface mount back boxes provided by ETC Faceplate Dimensions* gang * Height Width inches mm inches mm 1/2 4.5 114.3 1.75 44.5 1 4.5 114.3 2.8 71 Dimensions typical Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. 7181L1002 Rev. A Printed in USA 09/08 Unison® products protected by one or more of the following U.S. Patenten Numbers 5,323,088, 5,352,958 and 6,849,943; European Pateten Number 0603333; German Patent Number 69203609; US and International patents pending 2 of 2 ETC Unison® Heritage™ Fader Stations Unison Control Series O r d e r i n g i n f o r m at i o n Heritage Fader Stations Model description Legend UH10100- __1F 1 gang, 1 fader Master UH10101- __1F 1 gang, 1 fader, 1 button Master, On/Off UH10101- __2F 1 gang, 1 fader, 1 button Master, Entry UH10101- __3F 1 gang, 1 fader, 1 button Master, Panic UH10102- __1F 1 gang, 1 fader, 2 buttons Master, Open, Close UH10102- __2F 1 gang, 1 fader, 2 buttons Master, On, Off G e n e r a l I n f o r m at i o n UH10105- __1F 1 gang, 1 fader, 5 buttons Master, Preset 1-4, Off Elegant and clean-lined, Unison Heritage controls are designed to complement – not to compete with – the aesthetics of any interior environment, while being easy to install using LinkConnect. Artful but durable, Heritage stations are engineered to stand up to the daily abuse of busy public areas. The Unison Heritage series of button/fader control stations can be customized to suit any décor and application – available in a wide range of sizes, colors and configurations. Choose from pre-configured button/fader combinations or put stations together to create endless combinations of controls. UH30407- __1F 3 gang, 4 fader, 7 buttons Manual, Record, Master, Zone 1-3, Preset 1-4, Off UH30412- __1F 3 gang, 4 fader, 12 buttons Manual, Record, Master, Zone 1-3, Preset 1-9, Off UH40707- __1F 4 gang, 7 fader, 7 buttons Manual, Record, Master, Zone 1-6, Preset 1-4, Off UH40712- __1F 4 gang, 7 fader, 12 buttons Manual, Record, Master, Zone 1-6, Preset 1-9, Off UH51007- __1F 5 gang, 10 fader, Manual, Record, Master, 7 buttons Zone 1-9, Preset 1-4, Off UH51012- __1F 5 gang, 10 fader, Manual, Record, Master, 12 buttons Zone 1-9, Preset 1-9, Off UH61307- __1F 6 gang, 13 fader, Manual, Record, Master, 7 buttons Zone 1-12, Preset 1-4, Off UH61312- __1F 6 gang, 13 fader, Manual, Record, Master, 12 buttons Zone 1-12, Preset 1-9, Off UH71607- __1F 7 gang, 16 fader, Manual, Record, Master, 7 buttons Zone 1-15, Preset 1-4, Off UH71612- __1F 7 gang, 16 fader, Manual, Record, Master, 12 buttons Zone 1-15, Preset 1-9, Off APPLICATIONS • Churches • Hotels • Convention Centers • Meeting Rooms • Schools • Restaurants FEATURES • LinkConnect – using Echelon® LonTalk® protocol with LinkPower, the two wire topology-free system gives you the freedom to put stations where you need them • Fastener Free Faceplate System – no visible means of attachment • ColorCondition – RGB LED’s allow for customized control indication on a per button or fader basis, unlocking the conditional logic capabilities of a Unison control system • Forever Legend System – complimentary colored standard or custom legend options using an indelible, laser-marking method • RemoteDirect – built in InfraRed (IR) receivers on every station allow for optional IR remote control at every station location • RealFade – physical slider controls for groups or zones with 1 to 16 faders per station, paired with up to 12 buttons • LockOut – configurable control lockout from the push of a button • Take Control – preset the faders on a Heritage fader station and then choose when to gain control of the lighting in a room, at exactly the right moment Enter station color code in __ space provided. 1 = Cream (RAL 9001) 2 = Ivory (RAL 1015) 3 = Gray (RAL 7001) 4 = Black (RAL 9004) 5 = Signal White (RAL 9003) Above stations flush mount (F) in industry standard gang boxes. (By Others) Also available in surface mount (S) and portable (P) configurations. (Contact ETC) 1 of 2 ETC Unison® Heritage™ Fader Stations Unison Control Series sp e ci f ic a t i o n s physical FUNCTIONAL • UL and cUL LISTED • CE Marked FUNCTIONAL • Operate default or custom system functions including preset selection, manual mode activation, record mode activation, station lockout, raise, lower, sequence control, zone on/off, room combine, macro activation and timed event override • Fader functions include master, zone, fade rate, or preset • Custom button and fader functionality programmable via LightDesigner configuration software • Programmable electronic lockout levels • Buttons allow programming of individual lockout levels. MECHANICAL • Standard configurations with 7 or 12 buttons and 4, 7, 10, 13 or 16 faders • Support for 1-12 buttons and 1-16 faders for custom applications, contact ETC • Enclosed electronics assembly • Faceplate with no visible means of attachment • 45mm slide potentiometer faders and cantilevered switch arrays with removable caps • Flush mount in industry standard back boxes • Surface mount back boxes available from manufacturer • Constructed of injection molded, ABS plastic in five standard colors, matched to RAL standard colors • Custom colors available with sample • Indelibly marked legends in a contrasting color • Integral RGB LED response indicator for each button and fader • Integrated IR receiver ELECTRICAL • Connect via Echelon® LinkPower® control network utilizing low voltage Class II wiring • Topology free and polarity independent wiring over Belden 8471 or equivalent, and (1) #14 ESD drain wire • Wiring may be bus, loop, home-run or any combination of these • All station terminations are connectorized. • UL and cUL LISTED, CE marked THERMAL • Ambient room temperature: 0-40°C / 32-104°F • Ambient humidity: 30-90% non-condensing Flush Backbox Dimensions* gang Height Depth mm inches mm inches mm 1 (RACO 690*) 3.75 95.3 2.0 50.8 2.5 63.5 3 (RACO 692 ) 3.75 95.3 6.4 162.6 2.5 63.5 4 (RACO 693 ) 3.75 95.3 8.2 208.3 2.5 63.5 5 (RACO 694*) 3.75 95.3 10.0 254.0 2.5 63.5 6 (RACO 695 ) 3.75 95.3 11.8 299.7 2.5 63.5 7 (by ETC) 3.75 95.3 13.6 345.4 2.5 63.5 * * * * Width inches Or equivalent Surface Backbox Dimensions* gang Height inches * mm Width inches mm Depth inches mm 1 4.6 116.8 2.9 73.7 2.5 63.5 3 4.6 116.8 6.9 175.3 2.5 63.5 4 4.6 116.8 8.7 221.0 2.5 63.5 5 4.6 116.8 10.5 266.7 2.5 63.5 6 4.6 116.8 12.3 312.4 2.5 63.5 7 (by ETC) 4.6 116.8 14.1 358.1 2.5 63.5 Surface mount back boxes provided by ETC Faceplate Dimensions* gang Height inches * mm Width inches mm 1 4.5 114.3 2.8 71.1 3 4.5 114.3 6.7 170.2 4 4.5 114.3 8.6 218.4 5 4.5 114.3 10.4 264.2 6 4.5 114.3 12.2 309.9 7 4.5 114.3 14.0 355.9 Weights and dimensions typical Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2008 ETC. All Rights Reserved. All product information and specifications subject to change. 7181L1001 Rev. A Printed in USA 09/08 Unison® products protected by one or more of the following U.S. Patenten Numbers 5,323,088, 5,352,958 and 6,849,943; European Pateten Number 0603333; German Patent Number 69203609; US and International patents pending 2 of 2 ETC® Unison® Paradigm® ControlDesigner™ Unison Software Series G e n e r a l I n f o r m at i o n g e n e r a l i n f o r m at i o n Companion to LightDesigner™, ControlDesigner software gives you the tools to create the look of your Touchscreen pages and other user interfaces, pre-visualizing your control interface. Free for download from ETC’s Web site www.etcconnect.com, ControlDesigner lets you choose from built-in graphics or build your own as you develop unique interfaces ahead of time and load them when you are ready. Change the look of the graphics by selecting from a variety of convenient ready-made themes, or easily design your own. Features • DesignView – create and edit control pages using buttons, faders, custom pages, pop-up windows, background images, animated clocks, transparent buttons, and navigation controls with animated page transitions, add pages to create and edit timed events within your system • ControlView – simulate each page, and the page transitions before uploading to the system • ThemeBuilder – design pages using standard graphics, then change the “skin” using built-in or custom graphics • Secure-It Touch – automatically create numeric passwordentry pages, protecting any page or control from access Applications • Churches • Schools • Restaurants • Hotels • Museums • Casinos • Ballrooms Minimum Computer Requirements • Windows 7 (Home Premium) or XP (Pro SP2) or better • 2 GHz Pentium 4 processor or better (Dual or Quad core recommended) • 1 GB of available hard drive space • 1 GB of RAM or better (2GB recommended) • Video Card capable of 1024x768 resolution (1280x1024 recommended) • Open GL Graphics Acceleration • Ethernet Port • USB Port or SD card slot • Keyboard and Mouse 1 of 2 ETC Unison® Paradigm® ControlDesigner™ Unison Software Series sp e ci f ic a t i o n s sp e ci f ic a t i o n s The Unison Paradigm ControlDesigner software program shall be an application software package that facilitates off-line Unison Paradigm Touchscreen station configuration • Software setup shall include Configuration and Design Wizards, to create a graphical representation of a control environment • The software program shall be downloadable from the manufacturer’s website free of charge Functions • Provides functionality to create and modify Pages for display on a specific type of Touchscreen Station • There shall be a wizard to assist with the creation of Pages • A single configuration for an Touchscreen Station shall be defined as a set of one or more Pages • Each Page shall have a background that may incorporate multiple images or animations • Pop-ups can be shown/hidden over any Page in a Configuration and more than one Popup can be shown at once • Pages may have multiple design elements that may be Controls, Indicators or both • Design elements shall have a user-defined size, position and z-order that cannot be changed from within the System • Each design element shall have between 1 and 256 states, each of which can have a distinct appearance • The appearance of a state can be taken from a Theme or imported image file • There shall be support for import of JPEG and PNG image formats • Transparency shall be supported • Animated images shall be supported • Transitions between states of design elements can be animated • Page transitions can be animated • Design elements shall have a visibility group and threshold • Design elements that are Controls shall have a lockout group and threshold • All text shall have a user-definable font family, size, color and alignment • There shall be at least the following types of design elements -- Label -- Level Indicator -- Button -- Fader (straight and curved) -- Clock (analog and digital) -- Numeric Keypad -- Tab -- Pages -- Pop-ups -- Frames • Pop-ups can be any fixed size up to the Page size • P op-ups will have a fixed position on screen (but may move when being shown/hidden) • Themes shall define a collection of consistent appearances and sounds for design elements • It shall be possible to change the Theme used for a particular Station without modifying the underlying design elements • There shall be tools to assist with the creation of new Themes • Shall allow sounds to be associated with a particular Page • S hall allow sounds to be associated with state transitions of particular design elements • S ounds may be used to provide Touchscreen interaction feedback • A Page can be designated as the Station inactivity Page • A Page can have a lockout group and threshold • A Tab can have a visibility group and threshold • There shall be a visualization interface for Page creation and editing • S tandard graphical interaction methods (drag-and-drop) shall be used to arrange design elements on Pages • There shall be a layout grid with user-defined spacing and color with associated snap-to-grid functionality • It shall be possible to reuse the graphical layout of a configuration independent of any assigned functionality • The Touchscreen design functionality shall be part of a separate application that can be used alongside LightDesigner Corporate Headquarters • 3031 Pleasant View Rd, PO Box 620979, Middleton WI 53562 0979 USA • Tel +1 608 831 4116 • Fax +1 608 836 1736 London, UK • Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK • Tel +44 (0)20 8896 1000 • Fax +44 (0)20 8896 2000 Rome, IT • Via Ennio Quirino Visconti, 11, 00193 Rome, Italy • Tel +39 (06) 32 111 683 • Fax +44 (0) 20 8752 8486 Holzkirchen, DE • Ohmstrasse 3, 83607 Holzkirchen, Germany • Tel +49 (80 24) 47 00-0 • Fax +49 (80 24) 47 00-3 00 Hong Kong • Room 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong • Tel +852 2799 1220 • Fax +852 2799 9325 Web • www.etcconnect.com • Copyright©2010 ETC. All Rights Reserved. All product information and specifications subject to change. 7180L1006 Rev. C Printed in USA 06/10 Unison® products protected by one or more of the following: U.S. Patent No. 5,323,088, 6,849,943, and 5,352,958; European Patent No. 0603333; German Patent No. 69203609; US and International patents pending 2 of 2 ETC Outlet Boxes Distribution Series G E N E R A L I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Outlet boxes are designed for surface or recess mounting in theatres, television studios and other spaces for distribution of lighting circuits. FEATURES PHYSICAL # of Outlets Surface and recess mounting available 1, 2, 3, 4, 5, 6, and 8 connectors Panel mount connector Options: Edison (20A) Stage Pin (20, 60 and 100 amp) Grounded Twist-Lock (20A) Over- and Under-hung U-bolt and C-clamp pipe mount options available UL and cUL Listed Fabricated from 18-gauge steel with 16-gauge covers and 14-gauge end caps Finished with fine-textured, scratch-resistant, black powder coat 2” or 3/4” labels with white numbers on black background (sized to match product) Pin outlets spaced on 1.25” or 3” centers Edison or Twist-Lock outlets spaced on 3” centers only Back box Dimensions 9100 Panel Widths 9200 Panel Widths PIN 1.25” 1 2,3,4 5,6 8 3” W x 6.25” H x 3.25” D 6” W x 6.25” H x 3.25” D 9” W x 6.25” H x 3.25” D 12” W x 6.25” H x 3.25” D 3” 6” 9” 12” 4” 7” 10” 13” Other 3.00” 1,2 3,4 5,6 8 6” W x 6.25” H x 3.25” D 12” W x 6.25” H x 3.25” D 18” W x 6.25” H x 3.25” D 24” W x 6.25” H x 3.25” D 6” 12” 18” 24” 7” 13” 19” 25” Standard Surface Mount Outlet Boxes Outlet Qty Edison Pin 3” Pin 1.25” Twistlock 1 2 3 4 5 6 8 9101A 9102A 9103A 9104A 9105A 9106A 9108A 9101B 9102B 9103B 9104B 9105B 9106B 9108B 9101BD 9102BD 9103BD 9104BD 9105BD 9106BD 9108BD 9101C 9102C 9103C 9104C 9105C 9106C 9108C Standard Recessed Mount Outlet Boxes Outlet Qty Edison Pin 3” Pin 1.25” Twistlock 1 2 3 4 5 6 8 9201A 9202A 9203A 9204A 9205A 9206A 9208A 9201B 9202B 9203B 9204B 9205B 9206B 9208B 9201BD 9202BD 9203BD 9204BD 9205BD 9206BD 9208BD 9201C 9202C 9203C 9204C 9205C 9206C 9208C To any 9100 series box, add “-U” (U-Bolt) or “-C” (C-clamp) after the connector type to indicate pipe mount option. For example, 9104B-U indicates surface mount, 4-outlet box with stage pin connectors and U-bolt pipe mounting kit. Pigtail Boxes Distribution Series G E N E R A L I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Pigtail boxes are designed for surface or recess mounting in theatres, television studios and other spaces for distribution of lighting circuits. FEATURES PHYSICAL # of Pigtails Surface and recess mounting available 1, 2, 3, 4, 5, 6, and 8 connectors 18”, 24” and 36” pigtails standard Connector Options: Edison (20A) Stage Pin (20, 60 and 100 amp) Grounded Twist-Lock (20A) Over- and Under-hung U-bolt and C-clamp pipe mount options available UL and cUL Listed Fabricated from 18-gauge steel with 16-gauge covers and 14-gauge end caps Finished with fine-textured, scratch-resistant, black powder coat 2” or 3/4” labels with white numbers on black background (sized to match product) Pin pigtails spaced on 1.25” or 3” centers Edison or Twist-Lock pigtails spaced on 3” centers only Back box Dimensions 9300 Panel Widths 9400 Panel Widths PIN 1.25” 1 2,3,4 5,6 8 3” W x 6.25” H x 3.25” D 6” W x 6.25” H x 3.25” D 9” W x 6.25” H x 3.25” D 12” W x 6.25” H x 3.25” D 3” 6” 9” 12” 4” 7” 10” 13” Other 3.00” 1,2 3,4 5,6 8 6” W x 6.25” H x 3.25” D 12” W x 6.25” H x 3.25” D 18” W x 6.25” H x 3.25” D 24” W x 6.25” H x 3.25” D 6” 12” 18” 24” 7” 13” 19” 25” Standard Surface Mount Pigtail Boxes Outlet Qty Edison Pin 3” Pin 1.25” Twistlock 1 2 3 4 5 6 8 9301A 9302A 9303A 9304A 9305A 9306A 9308A 9301B 9302B 9303B 9304B 9305B 9306B 9308B 9301BD 9302BD 9303BD 9304BD 9305BD 9306BD 9308BD 9301C 9302C 9303C 9304C 9305C 9306C 9308C Standard Recessed Mount Pigtail Boxes Outlet Qty Edison Pin 3” Pin 1.25” Twistlock 1 2 3 4 5 6 8 9401A 9402A 9403A 9404A 9405A 9406A 9408A 9401B 9402B 9403B 9404B 9405B 9406B 9408B 9401BD 9402BD 9403BD 9404BD 9405BD 9406BD 9408BD 9401C 9402C 9403C 9404C 9405C 9406C 9408C To any 9300 series box, add “-U” (U-Bolt) or “-C” (C-clamp) after the connector type to indicate pipe mount option. For example, 9304B-U indicates a surface mount box with 4-18” pigtails and stage pin connectors plus a U-bolt pipe mounting kit. Floor / Wall Pockets Distribution Series G E N E R A L I N F O R M AT I O N Floor and Wall Pockets are designed for recess mounting in floors and walls of theatres, television studios and other spaces for distribution of lighting circuits. FEATURES FLOOR POCKET WALL POCKET 1, 2, 3, 4, 5, and 6 connectors Connector Options: Edison (20A) Stage Pin (20, 60 and 100 amp) Grounded Twist-Lock (20A) UL and cUL Listed enclosure 3/8” cast iron hinged cover with a non-skid tread pattern and cable notches 3/4” labels with white numbers on black background Fabricated from 18-gauge steel with 16 gauge covers Finished with fine-textured, scratch-resistant, black powder coat 3/4” reverse-screened white-on-black polycarbonate adhesive labels O R D E R I N G I N F O R M AT I O N Standard Floor Pockets Model# Description 8501 8502 8503 8504 8505 8506 Floor Floor Floor Floor Floor Floor pocket, pocket, pocket, pocket, pocket, pocket, 1 2 3 4 5 6 outlet outlets outlets outlets outlets – Pin & Edison only outlets – Pin only Standard Wall Pockets Model# Description 9601 9602 9603 9604 9605 9606 Recess Recess Recess Recess Recess Recess Wall Wall Wall Wall Wall Wall pocket, pocket, pocket, pocket, pocket, pocket, 1 2 3 4 5 6 outlet outlets outlets outlets outlets – Pin only outlets – Pin only Add A (Edison), B (Stage Pin) or C (Twist lock) to part number to indicate connector type. For example, 9504B indicates a floor pocket with 4 stage pin connectors. Part numbers refer to 20A outlets; consult factory for alternate configurations. NEMA Panels Distribution Series G E N E R A L I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N An alternative to surface and recessed outlet boxes, NEMA Panels are designed for recessed mounting in discreet small spaces or existing back boxes – balcony rails and orchestra pits. Standard NEMA Outlet Panels Model# 9801B 9802B 9803B 9804B 9801C 9802C 9803C 9801A 9802A 9803A 9804A NEMA panels are designed for use with customer-supplied industry standard electrical back boxes. FEATURES PHYSICAL 1, 2, 3, and 4 connectors 20A Connector Options: Edison Stage Pin Grounded Twist-Lock UL and cUL Listed Fabricated of .125 aluminum Finished with fine-textured, scratch-resistant, black powder coat Custom finishes available 3/4” labels with white numbers on black background Surface mount back box available (3.5” deep) Stage Pin Panel, 1 outlet Stage Pin Panel, 2 outlets Stage Pin Panel, 3 outlets Stage Pin Panel, 4 outlets Twist-Lock Panel, 1 outlet Twist-Lock Panel, 2 outlets Twist-Lock Panel, 3 outlets Edison Panel, 1 outlet Edison Panel, 2 outlets Edison Panel, 3 outlets Edison Panel, 4 outlets Americas ■ Europe Unit 5, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK ■ Tel: +44 (0)20 8896 1000 ■ Fax: +44 (0)20 8896 2000 Asia ■ ■ 3030 Laura Lane, P.O. Box 620979, Middleton, WI 53562-0979 USA Description ■ ■ 695 696 697 698 695 697 699 695 696 697 698 Tel: +1 608 831 4116 ■ Fax: +1 608 836 1736 ■ Toll free: 800 688 4116 ■ Toll free fax: 800 555 8912 Room 605-606, Tower III Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong ■ Tel: +852 2799 1220 ■ Fax: +852 2799 9325 Web: www.etcconnect.com RACO Back Box Part # Email: (US) [email protected] ■ (UK) [email protected] ■ (Asia) [email protected] Copyright © 2003 ETC. All Rights Reserved. All product information and specifications subject to change. 7099L1004 Rev. A Printed in USA 04/03