The high quality and dependability of the ML5000 Series with the added advantage of an ergonomic reversed
quintuple nosepiecefor mounting extra objectives and an optional 50W illuminator.The ML5000Series
encompasses 12 standard configurations.
O V I E W I N GH E A D S
Availablewith standardbinocularheadsor trinocularheads:
Binocularhead:Inclinedat 30", rotatablethrough360'.
Dualgraduateddioptereyetubeswith interpupillary
adjustmentsof 52mm
to 72mm.
Trinocularhead:Inclinedat 30', rotatablethrough360'.
A slidingbeam splitterdirects 100% of the lightto the eyepiecesor 80%oIo
the cameraand 2O%o
to the eyepieces.
O TnITOcULAR
VIEWING
@ E Y E P I E CE S
PairedDIN KHW10Xwith 20mm fieldof
view, 22mm eye relief.
@ O E I CCT I V EC H A N GE R
Smoothoperating,ball bearingmounted
quintuple
ergonomic,reverse-angle,
nosepiece.
/
I
O erNocuLAR
HEAD
/ vrEWtNG
/A\
@oelecTtvEs
SM Semi Planachromats,
BF Semi
Planachromats,Planachromatsor
Phase Contrast.
@ STAGES
Fl at - t ops t age: 17 1 m mx 1 4 0 m m
surfacewith 80mm (X) by 52mm (Y)
movement,graduatedwith vernier
readingst o 0. 1m m ,d e ta c h a b l e
specimenguide,drop-downrightor lefthandedcontrols.An attachableclinical
specimenholderis availableat option.
@rur-rop
STAGE
@ CO I T I O E NS ER
An Achromatic,N.A. 1.25substage
condenserwith irisdiaphragmand filter
tray. Or, Zerniketype Phase condenser
N.A.1.25.
@ ILLUMINATOR
Variable-intensity
Koehlerillumination
for aperturesup to 1.25.Availablein 6V
30W (built-in)or 12V 50W (attached
lamp house)models.
^
Attachableclinical
specimenholder
(optional)
@ F O C U S I N GM O V E M E N T
Coaxialcoarseand fine focusing
controlswith graduationreading2
micronsper division.Incorporates
tensionadjustmentand safety Autofocus stop unit.
o
ML5200
FIE LDIR ISCO NTRO L
Lamphouseassemblyof the
Modelswith12V50W
halogenilluminator
SIZ EA ND W E I G H T
30W Models;
x 255mm(D)
x 395mm(H),
Binocular
Models:
195mm(W)
Netweighl6.4K9
x 255mm(D)
x 440mm(H),
Trinocular
Models:
195mm(W)
Netweight:
6.5K9
5OWModel s;
x 360mm(D)
Binocular
x 395mm(H),
Models:
195mm(W)
Netweight:7.5K9
x 360mm(D)
Trinocular
x 440mm(H),
Models:
195mm(W)
Netweight:7.OKg
,a
EIJI
MLSOOOSeries
TECHNO
-
|ABORATORY MICROSCOPES
PHASECONTRASTM|/CROSCOPES
I.ilfi
7
?
#$
ML5970
ORDERINGINFORMATION FOR ML5OOOSER'ES
ML5000
M L5100
ML5050
M L5150
ML5200
ML5300
ML5400
ML5500
ML5855
ML5955
ML5870
ML5970
Binocular
Trinocular
Binocular
Trinocular
S M S e m i P l a n4 X , 1 0 X ,
S 4 0 X ,5 1 0 0 X o i l
KHW1OX,
20mm
f .o .v .
BF Se miP l an4X , 10X ,
S 4 0 X 5100X
.
oi l
Binocular
Trinocular
Binocular
Trinocular
Binocular
Trinocular
Binocular
Trinocular
Planachromat
4X, 10X,
S 4 0 X 5100X
,
oi l
AchromatPhase10X,
S20X,S40X,5100Xoil
BF Semi PlanPhase10X,
S20X, S40X, 3100X oil
Flat-top,
80mm x 52mm
movement,with
(righthand contorol)
Achromatic
N . A .1 . 2 5
withbluefilter
Koehler6V 30W
Halogen
Koehler12V50W
Halogen
Zernike type
Phase condenser
N.A.1.25 with green filter
Zernike type
Phase condenserN.A.l
with green interference
.25
filter
Koehler6V 30W
Halogen
Koehler12V50W
Halogen
. Suppliedin styrofoamcasewith dustcoverand instructionmanual.
. Lefthandcontrolmechanicalstageis optional.Pleaseindicatethe letter"L" afterthe modelnumberwhenorderingthe ML5000series
microscopewith lefthandcontrolmechanicalstage(For instance:lvodelML5000L).
YMEIJI
TECHNO
NILSOOOSeries
L^J
II,BORATORY M|,CROSCOPES
^
PHASECONTRAST
SET,PH.A
comprising:
MA715 Zerniketype N.A. 1.25 Phasecondenserin turretmount,
p h a s ea n n u l ifo r 1 0 X ,20X ,40Xand
indiv idual
c e n te ra b l e
positionwith irisand filtertrayfor 29.8mm
100Xwithbrightfield
diameterfilter
MA695 B F S em i P l a n a c h ro m aPh
t a s eo b j e c ti v e1 0 X ,N .A .0.25
MA697 BF Semi PlanachromatPhaseobjectivesS20X, N.A. 0.40
MA698 BF Semi Planachromat
PhaseobjectivesS40X, N.A. 0.65
MA699 BF Semi PlanachromatPhaseobjectivesS100X,N.A. 1.25 oil
MA458 Centeringtelescopeto check phaseannulus
MA759 Greeninterference
filter,29.8mmdiameter.
Theunittisequipped
inModels:
M15870
andM15970.
PH.A
P H A S EC O N T R A SSTE T .P H - B
,-,
comprising:
MA715 Zerniketype N.A. 1.25 Phasecondenserin turretmount,
p h a s ea n n u l ifo r 1 0 X,2 0X ,40Xand
indiv idual
c e n te ra b l e
positionwith irisand filtertrayfor 29.Bmm
100Xwithbrightfield
diameterfilter
MA4 4 8 DI N A c hr om a P
t h a s eo b j e c ti v e1 0 X ,N .A.0 .25
MA449 DIN AchromatPhaseobjectivesS20X, N.A. 0.40
MA450 DIN AchromatPhaseobjectivesS40X, N.A. 0.65
MA4 5 1 DI N A c hr om a P
t h a s eo b j e c ti v e 5
s 1 0 0 X,N .A . 1.25oi l
M4458 Centeringtelescopeto checkphaseannulus
MA290/05
Greenclearfilter,29.8mmdiameter.
PH-B
Theunittisequipped
in Models:
M15855
andM15955.
,-
P H A S EA N D D A R K F I E LS
DE T .P D - A
co mpr is ing:
MA716 Zerniketype N.A. 1.25 Phasecondenserin turretmount,
p h a s ea n n u l ifo r 1 0 X,2 0X and 40X ,
indiv idual
c e n te ra b l e
darkfieldstop for 40X and irisand filtertray for 29.8mm
diameterfilter
MA4 4 8 DI N A c hr oma Ph
t a s eo b j e c ti v e1 0 X,N .A .0 . 25
M4449 DIN AchromatPhaseobjectivesS20X, N.A. 0.40
MA450 DIN AchromatPhaseobjectivesS40X, N.A. 0.65
MA458 Centeringtelescopeto check phaseannulus
MA290/05
Greenclearfilter.29.8mmdiameter
€q
ad4)
4t
g;l
pD_A
ACCESSORIES
FORHIGHPOWER
DARKFIELD
MICROSCOPY
MA274 Darkfieldcondenser,Cardiodtype,for high power use (N.A.
1.25)in a centeringmount(to be used with 100Xobjective
wit h ir isonly ).
t 0 X ,N .A .0 .9 5o i l ,w i th i ri s
MA8 1 1 B F S em i pla n a c h ro maS5
diaphragm
MA8 1 3 B F S em ipla n a c h ro ma5t1 0 0 X ,N .A . 1 .2 5o il ,w i th i ri s
diaphr agm
MA4 3 0 S . P lanobje c ti v e 5
s 1 0 0 Xo i l ,w i th i ri sd i a p h ragm
Darkfield
condenser
andobjectives
withirisdiaphragm
AND ACCESSORI
ES
COMPONEIVTS
VIEWING HEADS (without eyepieces)
M4403 InclinedMonocularhead
MA6 0 2 I nc linedB in o c u l ahr e a d
MA603 InclinedTrinocularhead
EYEPI
ECES
MA 406 D IN H W F10X ,Fi el dN o.18,E ye R el i ef24mm (ea)
MA 407 D IN K H W 10X ,Fi el dN o.20,E ye R el i ef22mm(ea)
M A 4 0 8 D I NH W F 1 5 XF
, i e l dN o . 1 2 . 2E, y e R e l i e f1 5 m m( e a )
MA 409 D IN H W F20X ,Fi el dN o.9,E ye R el i ef9mm (ea)
A
G..7MErJl
.
MLSOOO Series
LA.JTECHNO
C
LABO RATORY MI CROSCOPES
ACHROMAT
OBJECTIVES
M A 482
M A 483
M A 484
M A 485
M A 486
M A 487
BF SEMI PLANACHROMAT OBJEITIVES
MA 690
MA 691
MA 692
MA 693
MA 694
MA 696
MA811
MA 813
S . F la ta c h ro m a 4t X, N .A .0 .1 0 ,W.D . 20.0mm
S . F la ta c h ro m a t1 0 X,N .A.0 .2 5 ,W.D .6.6mm
t 0 X ,N .A.0 .4 0 ,W.D .3.1mm
S . F la ta c h ro m a S2
S . F la ta c h ro m a S4
t 0 X ,N .A.0 .6 5 ,W.D .0.4mm
S . F la ta c h ro m a S6
t 0 X ,N .A .0 .8 5 ,W.D .0.2mm
S . F la ta c h ro m a 3t 1 0 0 X,N .A. 1.2 5 ,W .D .0.13mm
SM SEMI PLANACHROMAT OBJEITIVES
-
MA611
MA612
MA613
MA614
M A 615
MA616
MA617
B FS emiP l an4X ,N .A ,0,10.W .D ,19. 83m m
W .D .6. 23m m
B FS emiP l an10X ,N ,A .0.25,
B F S emiP l anS 20XN
W .D . 3. 1m m
, .A .0.40,
B F S emiP l anS 40XN
W .D . 0. 43m m
, .A .0.65,
B FS emiP l anS 50Xoi
, l ,N .A .0.95,W .D. 0, 25m m
B FS emiP l an5100XN
, .A .1.25.,
oi l ,W. D. O . 15m m
BFSemiPlanS50X.
N.A.0.95.
oil.withiris.W.D.0.24mm
B FS emi
P l an
N..A1.25..
.
W. D. 0. 15m m
S 100X
oi l w
. i thi ris.
S M S e m iP l a n4 X , N . A .0 . 1 0 ,W . D . 1 9 . 8 3 m m
S M S e m iP l a n5 X , N . A .0 . 1 0 ,W . D . 1 9 . B 3 m m
S M S e m iP l a n1 0 X ,N . A .0 . 2 5 ,W . D . 6 . 2 3 m m
S M S e m iP l a nS 2 0 X ,N . A .0 . 4 0 ,W . D . 3 . 1 3 m m
S M S e m i P l a nS4 0 X ,N .A .0 .6 5 ,W.D .0.43mm
S M S e m iP l a nS 6 0 X ,N . A .0 . 8 5 ,W . D . 0 . 2 3 m m
S MS e m P
i l a n5 1 0 0 XN, . A .1 . 2 5 .o, i l ,W . D . 0 . 1 2 m m
rp,
,
,,.,1,irr.9",
.i<z-,.W[S;))
B F S E M IP L A N O B J E C T I V E S
lY**i*'€'t
,__:=tgi{6;irryt'
-
w
- g1/z'
MISCELLANEOUS COMPONENTS
MA326
Sparebulb 6V 30W halogen
MA275|OSSparebuld 12V 50W halogen
MA327
Fuse 3A
MA609/05 Wooden carryingcase
MA676
Attachable
clinical
specimen
holderfor MA596R
Mechanical
stage
MA680
Polarizer
setfor 30Wversion(Polarizer
to fitfilter
tray/analyser
to fit viewinghead)
Polarizerset for 50W version(Polarizerto fit
MA681
filtertraylanalyser
to fit viewinghead)
MATOO l mmersi onoi l
MA7O1
Dustcover
vl
S M S E M I P L A NO B J E C T I V E S
F IL T E R S
MA196
MAl97
MA289/05
MA290/05
MA759
MA291
ND2Neutral
density
filter,29.Bmm
diameter
filter,29.8mmdiameter
ND8Neutral
density
Blueclearfilter,29.8mmdiameter
diameter
Greenclearfilter,29.Bmm
filter,29.8mmdiameter
Greeninterference
Polarizinq
filter,29.8mmdiameter
E Y E P T E C EM T C R O M E T E R S( F O R U S E W | T H M A 4 0 7 E Y E P I E C E )
reticule,
21mmdiameter
MA284
Cross-line
O mm
di ameter
M A 255
E y e p i e cmi
e c ro me te1r,
d i v i d e idn to100uni ts,2l mm
MA256
Eyepiece
micrometer
5mmdividedinto100units,21mmdiameter
21mmdiameter
MA283/05 1Omm
squaredividedinto100parts,1.0mmsquare,
g
ra
d
u
a
ti
o
n
s
,
2 1 mmdi ameter
M A 540
Cr o s s -l i nwei th0 .1 m m
reticule
21mmdiameter
MA254/05 WaltonandBeckett
/-h
tt\
, Z \
/
,/..'--\
t-fi-fl-ttfl-n
/
ffi
/ f f i \
I f f i l
l f f i l
t----f--]
\
\
\l-#t
\ f f i 1
\
ffi
\l-l
MA284
Cross-line
STAGE MICROMETERS
MA285 Objective
micrometer,
ruling
0.01mm
MA286 0.04"
divided
into40units,
0,001"
\-./
MA255
MA256
1 O mmi n 1 0 0p a rts Smmi n 1 0 0parts
/
MA283/05
1Ommsquarei n
100square
1mmdi videdint o
100parts
FZIMEIJI
L-.ITECHNO
V I D E OE Q U I P M E N T
450linesof
CK3100NCCDColorTV camera.1/3"CCD,
resolution,
NTSCsystemwithDC12Vadapter
450linesof
CK3100PCCDColorTV camera.1/3"CCD,
resolution,
PALsystemwithDC12Vadapter
450 linesof
CK3900NCCDColorTV camera.1|2"CCD,
NTSCsystemwithDC12Vadapter
resolution,
450linesof
CK3900PCCDColorTV camera.1/2"CCD,
PALsystemwithDC12Vadapter
resolution,
VIDEO"C" MOUNTS
MAl51/l0
"C"mount
adapter
(Replaces
existingphototube)
MAl51/35/04 "C"mount
adapterwith0.45Xlens
(Slipsovertop of existingphototube)
DIGITALCAMERAADAPTERS
MA151/30/50 DigitalCamera adapterfor use with Nikon
Coolpix95O,990, 995 and 4500 digitalcameras.
(Slipsover top of existingphototube)
adapterwith1.0Xlens
MA151/35/15"C"mount
(Slipsovertop of existingphototube)
MAl51/30/60 DigitalCamera adapterfor use with Olimpus
CamediaC-3040ZOOM, C-4040ZOOM and
C-3100ZOOM. (Slipsover top of existing
phototube)
MA151/35/20"C"mount
adapterwith0.7Xlens
(Slipsovertop of existingphototube)
MAl51/30t70 DigitalCamera adapterfor use with Nikon
Coolpix5000(Slipsover top of Existingphototube)
MAl51/35/25 "C"mount
adapterwith2.5Xlens
(Slipsovertop of existingphototube)
MA151/30/80 DigitalCamera adapterfor use with Fuji Finepix
5602 49002,.69002(Slipsover top of Existing
phototube)
photomicrography
for 35mmSLRcamera
Thefollowing
accessories
arerequired
1. CameraAttachment
models
to fit to ohototubeof trinocular
MAl50/50 Cameraattachment
finder
as above,butwitheyepiece
MAl50/60 Cameraattachment
2. Photo Eyepiece
MA512
MA508
MA500
powerby 2.5Xat thefilmplane)
2.5X(Magnifies
Photoeyepiece
objective
powerby 5X at thefilmplane)
Photoeyepiece
objective
5X (Magnifies
powerby 3.3Xat thefilmplane,withreticlemount)
Photoeyepiece
objective
3.3X(Magnifies
MAl50/60
3.T-2AdapterRing
T2-1
T2-2
T2-g
T2-4
T2-5
Adapterringfor CANONcamera
Adapterringfor MINOLTAcamera
Adapterringfor PENTAXK, RICOH-XR
camera
Adapterringfor PENTAXS camera
Adapterringfor NIKONcamera
T2-G Adapterringfor OLYMPUScamera
T2-7 Adapterringfor CONTAX,YASHIKAca-mera
T2-8 Adapterringfor KONICAcamera
T2-9 Adapterringfor CANONEOScamera
T2-1OAdapterringfor MINOLTAA, MAXIM2000camera
Agent:
MEIJITECHNO CO.,LTD.
MEIJI TEGHM)
i, Iruma-gun
322-l,ChikumazawaMiyoshi-mach
Saitama354-0043,Japan
E-mail: [email protected]
Phone: (0)49-259-0111
Fax : (0)49-259-0113
MEIJI TECHNO AMERICA
5895 Rue Ferrari, San Jose, CA 95138, USA
Tel : 408-226-3454 Fax: 408-226-0900
Toll Free : 1-800-832-0060
E-mail : [email protected]
http://www. meij itechno.com