Brochure - Meiji Techno America
Transcription
Brochure - Meiji Techno America
itilthg'3wr/fiti lllJi/JS.PE:,!l The high quality and dependability of the ML5000 Series with the added advantage of an ergonomic reversed quintuple nosepiecefor mounting extra objectives and an optional 50W illuminator.The ML5000Series encompasses 12 standard configurations. O V I E W I N GH E A D S Availablewith standardbinocularheadsor trinocularheads: Binocularhead:Inclinedat 30", rotatablethrough360'. Dualgraduateddioptereyetubeswith interpupillary adjustmentsof 52mm to 72mm. Trinocularhead:Inclinedat 30', rotatablethrough360'. A slidingbeam splitterdirects 100% of the lightto the eyepiecesor 80%oIo the cameraand 2O%o to the eyepieces. O TnITOcULAR VIEWING @ E Y E P I E CE S PairedDIN KHW10Xwith 20mm fieldof view, 22mm eye relief. @ O E I CCT I V EC H A N GE R Smoothoperating,ball bearingmounted quintuple ergonomic,reverse-angle, nosepiece. / I O erNocuLAR HEAD / vrEWtNG /A\ @oelecTtvEs SM Semi Planachromats, BF Semi Planachromats,Planachromatsor Phase Contrast. @ STAGES Fl at - t ops t age: 17 1 m mx 1 4 0 m m surfacewith 80mm (X) by 52mm (Y) movement,graduatedwith vernier readingst o 0. 1m m ,d e ta c h a b l e specimenguide,drop-downrightor lefthandedcontrols.An attachableclinical specimenholderis availableat option. @rur-rop STAGE @ CO I T I O E NS ER An Achromatic,N.A. 1.25substage condenserwith irisdiaphragmand filter tray. Or, Zerniketype Phase condenser N.A.1.25. @ ILLUMINATOR Variable-intensity Koehlerillumination for aperturesup to 1.25.Availablein 6V 30W (built-in)or 12V 50W (attached lamp house)models. ^ Attachableclinical specimenholder (optional) @ F O C U S I N GM O V E M E N T Coaxialcoarseand fine focusing controlswith graduationreading2 micronsper division.Incorporates tensionadjustmentand safety Autofocus stop unit. o ML5200 FIE LDIR ISCO NTRO L Lamphouseassemblyof the Modelswith12V50W halogenilluminator SIZ EA ND W E I G H T 30W Models; x 255mm(D) x 395mm(H), Binocular Models: 195mm(W) Netweighl6.4K9 x 255mm(D) x 440mm(H), Trinocular Models: 195mm(W) Netweight: 6.5K9 5OWModel s; x 360mm(D) Binocular x 395mm(H), Models: 195mm(W) Netweight:7.5K9 x 360mm(D) Trinocular x 440mm(H), Models: 195mm(W) Netweight:7.OKg ,a EIJI MLSOOOSeries TECHNO - |ABORATORY MICROSCOPES PHASECONTRASTM|/CROSCOPES I.ilfi 7 ? #$ ML5970 ORDERINGINFORMATION FOR ML5OOOSER'ES ML5000 M L5100 ML5050 M L5150 ML5200 ML5300 ML5400 ML5500 ML5855 ML5955 ML5870 ML5970 Binocular Trinocular Binocular Trinocular S M S e m i P l a n4 X , 1 0 X , S 4 0 X ,5 1 0 0 X o i l KHW1OX, 20mm f .o .v . BF Se miP l an4X , 10X , S 4 0 X 5100X . oi l Binocular Trinocular Binocular Trinocular Binocular Trinocular Binocular Trinocular Planachromat 4X, 10X, S 4 0 X 5100X , oi l AchromatPhase10X, S20X,S40X,5100Xoil BF Semi PlanPhase10X, S20X, S40X, 3100X oil Flat-top, 80mm x 52mm movement,with (righthand contorol) Achromatic N . A .1 . 2 5 withbluefilter Koehler6V 30W Halogen Koehler12V50W Halogen Zernike type Phase condenser N.A.1.25 with green filter Zernike type Phase condenserN.A.l with green interference .25 filter Koehler6V 30W Halogen Koehler12V50W Halogen . Suppliedin styrofoamcasewith dustcoverand instructionmanual. . Lefthandcontrolmechanicalstageis optional.Pleaseindicatethe letter"L" afterthe modelnumberwhenorderingthe ML5000series microscopewith lefthandcontrolmechanicalstage(For instance:lvodelML5000L). YMEIJI TECHNO NILSOOOSeries L^J II,BORATORY M|,CROSCOPES ^ PHASECONTRAST SET,PH.A comprising: MA715 Zerniketype N.A. 1.25 Phasecondenserin turretmount, p h a s ea n n u l ifo r 1 0 X ,20X ,40Xand indiv idual c e n te ra b l e positionwith irisand filtertrayfor 29.8mm 100Xwithbrightfield diameterfilter MA695 B F S em i P l a n a c h ro m aPh t a s eo b j e c ti v e1 0 X ,N .A .0.25 MA697 BF Semi PlanachromatPhaseobjectivesS20X, N.A. 0.40 MA698 BF Semi Planachromat PhaseobjectivesS40X, N.A. 0.65 MA699 BF Semi PlanachromatPhaseobjectivesS100X,N.A. 1.25 oil MA458 Centeringtelescopeto check phaseannulus MA759 Greeninterference filter,29.8mmdiameter. Theunittisequipped inModels: M15870 andM15970. PH.A P H A S EC O N T R A SSTE T .P H - B ,-, comprising: MA715 Zerniketype N.A. 1.25 Phasecondenserin turretmount, p h a s ea n n u l ifo r 1 0 X,2 0X ,40Xand indiv idual c e n te ra b l e positionwith irisand filtertrayfor 29.Bmm 100Xwithbrightfield diameterfilter MA4 4 8 DI N A c hr om a P t h a s eo b j e c ti v e1 0 X ,N .A.0 .25 MA449 DIN AchromatPhaseobjectivesS20X, N.A. 0.40 MA450 DIN AchromatPhaseobjectivesS40X, N.A. 0.65 MA4 5 1 DI N A c hr om a P t h a s eo b j e c ti v e 5 s 1 0 0 X,N .A . 1.25oi l M4458 Centeringtelescopeto checkphaseannulus MA290/05 Greenclearfilter,29.8mmdiameter. PH-B Theunittisequipped in Models: M15855 andM15955. ,- P H A S EA N D D A R K F I E LS DE T .P D - A co mpr is ing: MA716 Zerniketype N.A. 1.25 Phasecondenserin turretmount, p h a s ea n n u l ifo r 1 0 X,2 0X and 40X , indiv idual c e n te ra b l e darkfieldstop for 40X and irisand filtertray for 29.8mm diameterfilter MA4 4 8 DI N A c hr oma Ph t a s eo b j e c ti v e1 0 X,N .A .0 . 25 M4449 DIN AchromatPhaseobjectivesS20X, N.A. 0.40 MA450 DIN AchromatPhaseobjectivesS40X, N.A. 0.65 MA458 Centeringtelescopeto check phaseannulus MA290/05 Greenclearfilter.29.8mmdiameter €q ad4) 4t g;l pD_A ACCESSORIES FORHIGHPOWER DARKFIELD MICROSCOPY MA274 Darkfieldcondenser,Cardiodtype,for high power use (N.A. 1.25)in a centeringmount(to be used with 100Xobjective wit h ir isonly ). t 0 X ,N .A .0 .9 5o i l ,w i th i ri s MA8 1 1 B F S em i pla n a c h ro maS5 diaphragm MA8 1 3 B F S em ipla n a c h ro ma5t1 0 0 X ,N .A . 1 .2 5o il ,w i th i ri s diaphr agm MA4 3 0 S . P lanobje c ti v e 5 s 1 0 0 Xo i l ,w i th i ri sd i a p h ragm Darkfield condenser andobjectives withirisdiaphragm AND ACCESSORI ES COMPONEIVTS VIEWING HEADS (without eyepieces) M4403 InclinedMonocularhead MA6 0 2 I nc linedB in o c u l ahr e a d MA603 InclinedTrinocularhead EYEPI ECES MA 406 D IN H W F10X ,Fi el dN o.18,E ye R el i ef24mm (ea) MA 407 D IN K H W 10X ,Fi el dN o.20,E ye R el i ef22mm(ea) M A 4 0 8 D I NH W F 1 5 XF , i e l dN o . 1 2 . 2E, y e R e l i e f1 5 m m( e a ) MA 409 D IN H W F20X ,Fi el dN o.9,E ye R el i ef9mm (ea) A G..7MErJl . MLSOOO Series LA.JTECHNO C LABO RATORY MI CROSCOPES ACHROMAT OBJECTIVES M A 482 M A 483 M A 484 M A 485 M A 486 M A 487 BF SEMI PLANACHROMAT OBJEITIVES MA 690 MA 691 MA 692 MA 693 MA 694 MA 696 MA811 MA 813 S . F la ta c h ro m a 4t X, N .A .0 .1 0 ,W.D . 20.0mm S . F la ta c h ro m a t1 0 X,N .A.0 .2 5 ,W.D .6.6mm t 0 X ,N .A.0 .4 0 ,W.D .3.1mm S . F la ta c h ro m a S2 S . F la ta c h ro m a S4 t 0 X ,N .A.0 .6 5 ,W.D .0.4mm S . F la ta c h ro m a S6 t 0 X ,N .A .0 .8 5 ,W.D .0.2mm S . F la ta c h ro m a 3t 1 0 0 X,N .A. 1.2 5 ,W .D .0.13mm SM SEMI PLANACHROMAT OBJEITIVES - MA611 MA612 MA613 MA614 M A 615 MA616 MA617 B FS emiP l an4X ,N .A ,0,10.W .D ,19. 83m m W .D .6. 23m m B FS emiP l an10X ,N ,A .0.25, B F S emiP l anS 20XN W .D . 3. 1m m , .A .0.40, B F S emiP l anS 40XN W .D . 0. 43m m , .A .0.65, B FS emiP l anS 50Xoi , l ,N .A .0.95,W .D. 0, 25m m B FS emiP l an5100XN , .A .1.25., oi l ,W. D. O . 15m m BFSemiPlanS50X. N.A.0.95. oil.withiris.W.D.0.24mm B FS emi P l an N..A1.25.. . W. D. 0. 15m m S 100X oi l w . i thi ris. S M S e m iP l a n4 X , N . A .0 . 1 0 ,W . D . 1 9 . 8 3 m m S M S e m iP l a n5 X , N . A .0 . 1 0 ,W . D . 1 9 . B 3 m m S M S e m iP l a n1 0 X ,N . A .0 . 2 5 ,W . D . 6 . 2 3 m m S M S e m iP l a nS 2 0 X ,N . A .0 . 4 0 ,W . D . 3 . 1 3 m m S M S e m i P l a nS4 0 X ,N .A .0 .6 5 ,W.D .0.43mm S M S e m iP l a nS 6 0 X ,N . A .0 . 8 5 ,W . D . 0 . 2 3 m m S MS e m P i l a n5 1 0 0 XN, . A .1 . 2 5 .o, i l ,W . D . 0 . 1 2 m m rp, , ,,.,1,irr.9", .i<z-,.W[S;)) B F S E M IP L A N O B J E C T I V E S lY**i*'€'t ,__:=tgi{6;irryt' - w - g1/z' MISCELLANEOUS COMPONENTS MA326 Sparebulb 6V 30W halogen MA275|OSSparebuld 12V 50W halogen MA327 Fuse 3A MA609/05 Wooden carryingcase MA676 Attachable clinical specimen holderfor MA596R Mechanical stage MA680 Polarizer setfor 30Wversion(Polarizer to fitfilter tray/analyser to fit viewinghead) Polarizerset for 50W version(Polarizerto fit MA681 filtertraylanalyser to fit viewinghead) MATOO l mmersi onoi l MA7O1 Dustcover vl S M S E M I P L A NO B J E C T I V E S F IL T E R S MA196 MAl97 MA289/05 MA290/05 MA759 MA291 ND2Neutral density filter,29.Bmm diameter filter,29.8mmdiameter ND8Neutral density Blueclearfilter,29.8mmdiameter diameter Greenclearfilter,29.Bmm filter,29.8mmdiameter Greeninterference Polarizinq filter,29.8mmdiameter E Y E P T E C EM T C R O M E T E R S( F O R U S E W | T H M A 4 0 7 E Y E P I E C E ) reticule, 21mmdiameter MA284 Cross-line O mm di ameter M A 255 E y e p i e cmi e c ro me te1r, d i v i d e idn to100uni ts,2l mm MA256 Eyepiece micrometer 5mmdividedinto100units,21mmdiameter 21mmdiameter MA283/05 1Omm squaredividedinto100parts,1.0mmsquare, g ra d u a ti o n s , 2 1 mmdi ameter M A 540 Cr o s s -l i nwei th0 .1 m m reticule 21mmdiameter MA254/05 WaltonandBeckett /-h tt\ , Z \ / ,/..'--\ t-fi-fl-ttfl-n / ffi / f f i \ I f f i l l f f i l t----f--] \ \ \l-#t \ f f i 1 \ ffi \l-l MA284 Cross-line STAGE MICROMETERS MA285 Objective micrometer, ruling 0.01mm MA286 0.04" divided into40units, 0,001" \-./ MA255 MA256 1 O mmi n 1 0 0p a rts Smmi n 1 0 0parts / MA283/05 1Ommsquarei n 100square 1mmdi videdint o 100parts FZIMEIJI L-.ITECHNO V I D E OE Q U I P M E N T 450linesof CK3100NCCDColorTV camera.1/3"CCD, resolution, NTSCsystemwithDC12Vadapter 450linesof CK3100PCCDColorTV camera.1/3"CCD, resolution, PALsystemwithDC12Vadapter 450 linesof CK3900NCCDColorTV camera.1|2"CCD, NTSCsystemwithDC12Vadapter resolution, 450linesof CK3900PCCDColorTV camera.1/2"CCD, PALsystemwithDC12Vadapter resolution, VIDEO"C" MOUNTS MAl51/l0 "C"mount adapter (Replaces existingphototube) MAl51/35/04 "C"mount adapterwith0.45Xlens (Slipsovertop of existingphototube) DIGITALCAMERAADAPTERS MA151/30/50 DigitalCamera adapterfor use with Nikon Coolpix95O,990, 995 and 4500 digitalcameras. (Slipsover top of existingphototube) adapterwith1.0Xlens MA151/35/15"C"mount (Slipsovertop of existingphototube) MAl51/30/60 DigitalCamera adapterfor use with Olimpus CamediaC-3040ZOOM, C-4040ZOOM and C-3100ZOOM. (Slipsover top of existing phototube) MA151/35/20"C"mount adapterwith0.7Xlens (Slipsovertop of existingphototube) MAl51/30t70 DigitalCamera adapterfor use with Nikon Coolpix5000(Slipsover top of Existingphototube) MAl51/35/25 "C"mount adapterwith2.5Xlens (Slipsovertop of existingphototube) MA151/30/80 DigitalCamera adapterfor use with Fuji Finepix 5602 49002,.69002(Slipsover top of Existing phototube) photomicrography for 35mmSLRcamera Thefollowing accessories arerequired 1. CameraAttachment models to fit to ohototubeof trinocular MAl50/50 Cameraattachment finder as above,butwitheyepiece MAl50/60 Cameraattachment 2. Photo Eyepiece MA512 MA508 MA500 powerby 2.5Xat thefilmplane) 2.5X(Magnifies Photoeyepiece objective powerby 5X at thefilmplane) Photoeyepiece objective 5X (Magnifies powerby 3.3Xat thefilmplane,withreticlemount) Photoeyepiece objective 3.3X(Magnifies MAl50/60 3.T-2AdapterRing T2-1 T2-2 T2-g T2-4 T2-5 Adapterringfor CANONcamera Adapterringfor MINOLTAcamera Adapterringfor PENTAXK, RICOH-XR camera Adapterringfor PENTAXS camera Adapterringfor NIKONcamera T2-G Adapterringfor OLYMPUScamera T2-7 Adapterringfor CONTAX,YASHIKAca-mera T2-8 Adapterringfor KONICAcamera T2-9 Adapterringfor CANONEOScamera T2-1OAdapterringfor MINOLTAA, MAXIM2000camera Agent: MEIJITECHNO CO.,LTD. MEIJI TEGHM) i, Iruma-gun 322-l,ChikumazawaMiyoshi-mach Saitama354-0043,Japan E-mail: [email protected] Phone: (0)49-259-0111 Fax : (0)49-259-0113 MEIJI TECHNO AMERICA 5895 Rue Ferrari, San Jose, CA 95138, USA Tel : 408-226-3454 Fax: 408-226-0900 Toll Free : 1-800-832-0060 E-mail : [email protected] http://www. meij itechno.com