ansi/aama/nwwda 101/i
Transcription
ansi/aama/nwwda 101/i
WDMA HALLMARK CERTIFICATION PROGRAM REPORT SUBMISSION FORM THIS FORM IS TO BE COMPLETED BY THE MANUFACTURER AND SUBMITTED TO AMS PRIOR TO OR ALONG WITH SUBMISSION OF EACH NEW OR REVISED TEST REPORT FOR CERTIFICATION TO THE HALLMARK PROGRAM. ANY QUESTIONS PLEASE CONTACT AMS AT 315646-2234 OR [email protected]. Manufacturer: Eagle Window and Door, Inc. Contact: Todd Bergstrom Plant Location(s): Phone: 563-556-2270 (list all plants where product is made) 2045 Kerper Blvd. Dubuque, IA 52004-1072 Test Report #: 67830.01-602-44 Email: [email protected] Product Relationship: Extension of currently certified product? X yes If yes, what CCL # ? 099-H-652.01 Difference from Certified Product: Report re-written to A440.08 standard. Is this a Gateway Test ? yes no X n/a Does this report require a Gateway Report # ? yes no X n/a no n/a Impact Report: If this is not an impact report check here: X AWS Report # Test Plan # ? yes no X n/a Installation Instructions submitted ? yes no X n/a Certification to Florida: If this will not be submitted to Florida check here: AMS to Input to Database yes no n/a Manufacturer to input X yes no n/a WD-08 01/11/07 Recertification New (check one) Report #: X WDMA HALLMARK CERTIFICATION PROGRAM REPORT SUBMISSION FORM Product Name: (as to be listed on CCL) 4040 Axiom Clad Awning Vent Product Type: Awning Additional Manufacturer ID #: Hallmark CCL Standard ANSI/AAMA/NWWDA 101/I.S. 2 97 101/I.S.2/NAFS-02 AAMA/WDMA/CSA/101/I.S.2/A440-05 X AAMA/WDMA/CSA/101/I.S.2/A440-08 ASTM E 1996 99 / E1886-97 ASTM E 1996 01 / E1886-97 ASTM E 1996 02 / E1886-02 ASTM E 1996 03 / E1886-02 ASTM E 1996 04 / E1886-04 ASTM E 1996 05 / E1886-05 ASTM E330 02 ANSI A250.13-03 TAS 201-94 TAS 202-94 TAS 203-94 Other: WD-08 01/11/07 Rating n/a Architectural Testing AAMA/WDMA/CSA TEST REPORT Rendered to: EAGLE WINDOW & DOOR, INC. SERIES/MODEL: 4040 Axiom Clad Awning Vent PRODUCT TYPE: Aluminum Clad Awning Window Title AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/WDMA/CSA 101/I.S.2/A440-08 ANSI/AAMA/NWWDA 101/I.S. 2-97 Design Pressure* Operating Force (in motion) Air Infiltration Water Penetration Resistance Test Pressure* Uniform Load Structural Test Pressure Forced Entry Resistance *-Optional Secondary Designators Summary of Results AP-C45 1219 x 1219 (48 x 48) CW-PG45-AP 1219 x 1219 (48 x 48) AP-C45 (48 x 48) 2160 Pa (45.11 psf) 9 N (2 lbf) 0.05 L/s/m2 (0.01 cfm/ft2) 481 Pa (10.05 psf) ±3240 Pa (67.67 psf) Grade 10 Test Completion Date: 10/12/06 Reference must be made to Report No. 67830.01-602-44-R2, dated 11/21/08 for complete test specimen description and data. 5906 Saxon Avenue Schofield, WI 54476 phone: 715-241-8624 fax: 715-241-8425 www.archtest.com Architectural Testing AAMA/WDMA/CSA TEST REPORT Rendered to: EAGLE WINDOW & DOOR, INC. 2045 Kerper Boulevard Dubuque, Iowa 52004-1072 Report No.: 67830.01-602-44 Revision 2: 11/21/08 Revision 1: 11/06/06 Test Date: 10/02/06 Through: 10/12/06 Report Date: 10/19/06 Expiration Date: 10/12/10 Project Summary: Architectural Testing, Inc. was contracted by Eagle Window & Door, Inc. to perform testing on a Series/Model 4040 Axiom Clad Awning Vent, Aluminum Clad Awning Window at Architectural Testing, Inc. test facility in Schofield, Wisconsin. The sample tested successfully met the performance requirements for an AP-C45 1219 x 1219 (48 x 48), CW-PG45AP 1219 x 1219 (48 x 48) and AP-C45 (48 x 48) rating. Test specimen description and results are reported herein. Test Specification(s): The test specimen was evaluated in accordance with the following: AAMA/WDMA/CSA 101/I.S.2/A440-05, Standard/Specification for Windows, Doors and Unit Skylights. AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS Standard/Specification for Windows, Doors, and Skylights. North American Fenestration ANSI/AAMA/NWWDA 101/I.S. 2-97, Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors. Test Specimen Description: Series/Model: 4040 Axiom Clad Awning Vent Product Type: Aluminum Clad Awning Window Overall Size: 1219 mm (48") wide by 1219 mm (48") high Sash Size: 1181 mm (46-1/2") wide by 1181 mm (46-1/2") high Overall Area: 1.49 m2 (16.00 ft2) Finish: Interior wood was natural and the exterior aluminum cladding was white. 5906 Saxon Avenue Schofield, WI 54476 phone: 715-241-8624 fax: 715-241-8425 www.archtest.com Architectural Testing 67830.01-602-44 Page 2 of 6 Revision 1: 11/06/06 Revision 2: 11/21/08 Test Specimen Description: (Continued) Glazing Details: The window utilized a nominal 19.1 mm (3/4") thick insulating glass fabricated from two sheets of nominal 3.18 mm (1/8") annealed glass separated by an aluminum spacer system. The glass was set from the interior against butyl rubber mastic. Wood glazing stops with single sided adhesive foam tape were utilized on the interior and secured with 1-1/4" brads spaced 1" from each corner and 6" to 8" on center. Weatherstripping: Description Quantity Location 0.267" diameter hollow bulb 1 Row Sash stiles and top rail 0.320" diameter foam filled bulb 1 Row Interior frame perimeter Vinyl spline 1 Row Between frame jambs and stop Frame Construction: The wood frame was of laminated veneer lumber (LVL) with corners rabbet jointed, butted, sealed with silicone and secured with two (2) 7/16" crown by 1-1/2" long staples per corner. Extruded aluminum cladding was slip-fit over the wood frame members with the corners miter cut, sealed with silicone and secured with a nylon corner key and two (2) #8 x 7/16" screws. The head stop was secured with 3/16" crown by 1-1/8" long staples spaced approximately 10" on center. The side stops were secured with glue and a vinyl spline. The sill operator cover was secured with four (4) #8 x 2-1/8" screws spaced 3" and 103/4" from each end. Sash Construction: The sash members were of molded pine. The sash corners utilized mortise and tenon construction and were secured with glue and one (1) #7 x 1-1/4" screw per corner. Extruded aluminum cladding was slip-fit over the wood sash members with the corners miter cut, silicone sealed and secured with a nylon corner key and one (1) #5 x 1-1/2" screw per corner. Hardware: Description Quantity Location Dual arm operator 1 Frame sill at midspan Single point lock system 2 Locking jamb/stile, located 12-1/2" from bottom rail of the sash Lock keeper 2 Frame stile adjacent to locks 22" metal hinge with track 2 Frame stiles/rails at the top Metal sash retainer 1 Frame head at midspan Architectural Testing 67830.01-602-44 Page 3 of 6 Revision 1: 11/06/06 Revision 2: 11/21/08 Test Specimen Description: (Continued) Installation: The window was installed within a nominal double wood test buck. A 2"x SPF wood test buck surrounds the window with a 2"x12" SPF wood test buck incasing the smaller buck. The window was attached to the wood surround with an applied nailing fin which was set in silicone and secured with 2" nails spaced approximately 6" on center. Silicone sealant was also applied over the fastener heads. The test buck had a rough opening of 48-1/2" x 481/2". Test Results: The results are tabulated as follows: Paragraph Title of Test - Test Method Results Allowed 5.3.1 5.3.1 Operating Force ASTM E 2068 Initiate motion 13 N (3 lbf) Maintain motion 9 N (2 lbf) Latch 13 N (3 lbf) 70 N (15 lbf) 45 N (10 lbf) 100 N (22.5 lbf) 5.3.2 5.3.2 2.1.2 Air Leakage Resistance per ASTM E 283 75 Pa (1.57 psf) 0.05 L/s/m2 (0.01 cfm/ft2) See Note #1 1.5 L/s/m2 (0.3 cfm/ft2 max.) Note #1: The tested specimen meets (or exceeds) the performance levels specified in AAMA/WDMA/CSA 101/I.S.2/A440-05, AAMA/WDMA/CSA 101/I.S.2/A440-08 and ANSI/AAMA/NWWDA 101/I.S. 2-97 for air leakage resistance. 5.3.2.2 5.3.2.2 Canadian Infiltration/Exfiltration Level A3 75 Pa (1.6 psf) Infiltration <0.05 L/s/m² (<0.01 cfm/ft²) 75 Pa (1.6 psf) Exfiltration <0.05 L/s/m² (<0.01 cfm/ft²) 5.3.3.2 5.3.3.2 2.1.3 Water Penetration Resistance per ASTM E 547 and E 331 See Note #2 5.3.4.2 5.3.4.2 2.1.4.1 Uniform Load Deflection per ASTM E 330 See Note #2 5.3.4.3 5.3.4.3 2.1.4.2 Uniform Load Structural per ASTM E 330 See Note #2 0.50 L/s/m² max. (0.10 cfm/ft²) max. 0.50 L/s/m² max. (0.10 cfm/ft²) max. Note #2: The client opted to start at a pressure higher than the minimum required. Those results are listed under “Optional Performance.” Architectural Testing 67830.01-602-44 Page 4 of 6 Revision 1: 11/06/06 Revision 2: 11/21/08 Test Results: (Continued) Paragraph Title of Test - Test Method Results 5.3.5 5.3.5 2.1.8 Forced Entry Resistance per ASTM F 588 Type: B Grade: 10 Disassembly Test No entry Test B1 thru B3 No entry Hardware Manipulation Test No entry Sash Manipulation Test No entry No entry No entry No entry No entry 5.3.6.6.7 5.3.6.6.6 Awning Projected Hardware Load Test 140 N (30 lbf) 51.6 mm (2.03") 53.6 mm (2.11") 2.2.4.5.2 Sash Torsion Test 140 N (30 lbf) 53.6 mm (2.11") 51.6 mm (2.03") Allowed Optional Performance 4.4.2.6 4.3.2 4.3 Water Penetration Resistance per ASTM E 547 and E 331 481 Pa (10.05 psf) No leakage No leakage 4.4.2.6 4.3.2 4.4.1 Uniform Load Deflection per ASTM E 330 (Deflections reported were taken on the sash top rail) (Loads were held for 60 seconds) See Note #3 2160 Pa (45.11 psf) (positive) 0.25 mm (0.01") 3.30 mm (0.13") max. 2160 Pa (45.11 psf) (negative) 0.76 mm (0.03") 3.30 mm (0.13") max. 2249 Pa (47.00 psf) (positive) 0.25 mm (0.01") 3.30 mm (0.13") max. 2249 Pa (47.00 psf) (negative) 0.76 mm (0.03") 3.30 mm (0.13") max. Note #3: The Deflections reported are not limited by AAMA/WDMA/CSA 101/I.S.2/A440-05, AAMA/WDMA/CSA 101/I.S.2/A440-08 and ANSI/AAMA/NWWDA 101/I.S. 2-97 for this product designation. The deflection data is recorded in this report for special code compliance and information only. 4.4.2.6 4.3.2 4.4.2 Uniform Load Structural per ASTM E 330 (Permanent sets reported were taken on the sash top rail) (Loads were held for 10 seconds) 3240 Pa (67.67 psf) (positive) <0.25 mm (<0.01") 1.78 mm (0.07") max. 3240 Pa (67.67 psf) (negative) <0.25 mm (<0.01") 1.78 mm (0.07") max. 3373 Pa (70.50 psf) (positive) <0.25 mm (<0.01") 1.78 mm (0.07") max. 3373 Pa (70.50 psf) (negative) <0.25 mm (<0.01") 1.78 mm (0.07") max. Architectural Testing 67830.01-602-44 Page 5 of 6 Revision 1: 11/06/06 Revision 2: 11/21/08 Drawing Reference: The test specimen drawings have been reviewed by Architectural Testing, Inc. and match the test specimen reported herein. Detailed drawings, representative samples of the test specimen and a copy of this report will be retained by Architectural Testing, Inc. for a period of four years from the original test date. The above results were secured by using the designated test methods and they indicate compliance with the performance requirements of the above referenced specification. This report does not constitute certification of this product, which may only be granted by the certification program administrator. This report may not be reproduced, except in full, without the approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, INC. Audrey S. Matis Senior Technician ASM/hlc Attachments (Pages): Appendix A: Alteration Addendum (1) Appendix B: Installation Drawing (1) Appendix C: Drawings (45) Wanda L. Matis Senior Project Manager Architectural Testing 67830.01-602-44 Page 6 of 6 Revision 1: 11/06/06 Revision 2: 11/21/08 Revision Log Rev. # Date Page(s) Revision(s) 0 10/19/06 N/A Original report issue 1 11/06/06 Page 3 of 6 Under "Installation" sentence stating; "A masonry clip was utilized at midspan of both jambs and secured to the frame with four (4) #8 x 5/8" screws and to the wood surround with two (2) #8 x 1-1/2" screws." was removed. 2 11/21/08 All Test report results conducted prior to 2008 standard being published; report is as compared to 2008 standard. Report and drawings forwarded to AMS for Hallmark Certification. APPENDIX A Alteration Addendum Note: No alterations were required. APPENDIX B Installation Drawing APPENDIX C Drawings