1 Contents • Please read the manual carefully before using this unit

Transcription

1 Contents • Please read the manual carefully before using this unit
Contents
•
•
•
Please read the manual carefully before using this unit.
Please refer to cautions mentioned in the manual to avoid improper usage
of this unit.
Please keep the manual for your future reference.
Safety Cautions. .....................................................................................................2
Brief Introduction to PHC-208TM...........................................................................3
Description of the Main Unit ...................................................................................4
Operation for Manual Mode & Auto Mode .............................................................5
Electrodes & Accessories .......................................................................................6
Large LCD Screen Introduction ..............................................................................7
Operational Instructions .........................................................................................8
Maintenance and Storage after Use .......................................................................9
Acupoint Selection and Treatment for Discomfort ...............................................10
Acupoint Selection and Relief for Discomfort ................................................ 11-14
Diagram of Palm Reflection Zones & Treatment...................................................15
Diagram of Palm Reflection Zones & Treatment...................................................16
Troubles and Solutions .........................................................................................17
Specifications .......................................................................................................18
1
Safety Cautions
Brief Introduction to PHC-208TM
1 Never use the equipment with the following instruments:
•
Heart rate regulator and body built-in
electronic therapeutic instruments
•
Artificial cardiopneumatic pacemaker, electronic
life support and treatment instruments
•
Cardiometer and ambulatory electronic
therapeutic instruments
Properties
2 It is advised to follow a doctor’s advice for patients who are under medical
treatment or suffering from the following:
•
Malignant tumor
•
VD infection
•
In menstrual phase or pregnancy
•
Do not adopt the equipment near heart for heart disease patients
•
Fever above 38°C
•
Abnormal cutaneous anaphylaxis
•
Do not adopt the equipment at the diseased heat region, eyeballs, inside
mouth, genital parts and external skin trauma
•
Do not use the equipment simultaneously with other instruments
Brief Introduction of PHC-208TM
3 Cautions
•
When you feel discomfort or abnormality while use, stop using and contact
your doctor
•
Keep away from babies, children and others who are not able to express
themselves freely
•
Avoid moisture, high temperature and using in the bath or bath place
•
Do not put battery into fire as it may explode and cause an accident
•
Do not attempt any repair; contact your local dealer for any technical
assistance and or product failure
PHC-208TM is based on super low frequency electrotherapy. The objective is to
produce a therapeutic effect similar to the one produced using a traditional Chinese
acupuncture needle. The low frequency electrical impulses stimulate your main and
collateral body accupoints imitating the actual feeling of massaging, pounding on your
back, performing acupuncture and applying cupping techniques. The user may feel
relief immediately for acute conditions such as gasteralgia or lower limb pains by using
the PHC-208TM.
PHC-208TM offers the latest advances as a new generation health-care product. The
PHC-208TM is an advanced user friendly TENS instrument. It applies the physics of
bionics, traditional Chinese medicine, and clinical treatment methods. It offers not only
the seven functions presented in our previous product series, but has added distinctive
capabilities in treating Hypertension and Hypotension.
PHC-208TM Functional Advantages
•
•
•
•
•
•
•
•
Therapeutic Indications
1.
2.
3.
2
Advanced microcomputer control system with safe, easy operation
Eight selectable functions that can be adjusted based on users’ preference:
Acupuncture, Massage, Scraping, Beating, Manipulation, Slimming, Blood
Pressure and Feet-cure
Large LCD screen with easy to read full featured body display
30 mins auto-off system that automatically switches off the unit after use
User selectable AUTO and MANUAL Modes with the eight functions that can
be automatically circulated step by step under AUTO Mode
Intensity automatically adjusts to the lowest level each time when the function
is changed manually to assure optimum comfort and safety
Medical pads and Acupoint Pen can be freely applied to any part of the body
and attached to the separate feet massage slipper
Smart outlook, portable and easy to carry
General malaise: fatigue, nervosism, sore waste and back, shoulder and leg.
A large variety of chronic diseases that can be cured by acupuncture and
manipulation: stain, gasteralgia, toothache, ischialgia, menoxenia, impotence,
sexual disorder and others.
Hairdressing: bantingism, post partum belly looseness, hump breast, facial
ache and facial pigment ediment.
3
Description of the Main Unit
Operation for Manual Mode & Auto Mode
Components of Main Unit
➅
Operation for Manual Mode & Auto Mode
Electrode Socket
➄
➀
Language Selection Key
LCD Screen
Power Switch Key (On/Off)
➂ Intensity Increase Key
➃ Intensity Decrease Key
➁
Function Selection Key
Components & Functions of Main Unit
1. Mode selection: Manual/Auto Mode.
1) The Mode is Manual Mode after opening the device,
and it can be changed to Auto Mode
➃
once pressing 4 over 3 seconds.
2) Change Manual Mode to Auto Mode, and the intensity
degree decreases 1, and the time changes to 03 minutes.
3) Change Auto Mode to Manual Mode, and the intensity
degree becomes 01, and the time changes to 30 minutes.
➁
2. Manual Mode:
1) Under Manual Mode, Press 2 to change the function to next one that user needs,
and the LCD arrow will direct the selected function, and the time is 30 minutes.
2) The intensity is 01 automatically to avoid the sudden change. Press 3 or 4 to in
crease or decrease the intensity.
1 Power Switch key:
Open: Press it to start, the original LCD shows: Manual Mode, the arrow directs
function of Massage, intensity is 01, and time is 30 minutes.
Close: Press it over 3 seconds to close, or close automatically after 30 minutes.
2 Function Selection key:
Press it to select eight functions: Acupuncture, Massage, Scraping, Beating,
Manipulation, Slimming, Blood Pressure, Feet-cure.
3 Intensity Increase key:
Press once to increase 1 degree, and the maximum degree is 32.
3. Auto Mode:
1) Under Auto Mode, and the function can be automatically
changed from Massage to Feet-cure every 3 minutes.
2) The time for each function is 3 minutes,
and the device will be switched off automatically
➃
after all functions finish.
3) Under Auto Mode, the intensity doesn’t change when the
function changes, and press 3 or 4 to in/decrease intensity.
➁
➂
4 Intensity Decrease key / Manual/Auto Mode Key:
Press once to decrease 1 degree, and the minimum degree is 01.
Press this key over 3 seconds, Mode can be changed freely between Auto and
Manual.
5 LCD Screen: Directly shows the output condition.
6 Electrode Socket: Insert the plug to the device.
4
Treatment Guide
1) A standard number of treatments per day is 1-2. Some people may feel tired
during the first week of use. In this case, lower the intensity, shorten the time,
and also limit the number of treatments to one a day.
2) Duration — 10 to 15 minutes for each region
5
ELECTRODES & ACCESSORIES
ELECTRODES
Large LCD Screen Introduction
Electrodes
Chord
Plug
Acupoint pen
Big Adhering Pads (x2)
ACCESSORIES
chord winder, leather bag, battery, foam plastic box.
Foam Plastic Box
Leather Bag
NOTE:
7” Battery (AAAX3)
When the function is certainly adjusted, the corresponding black points are shown
on the human body simultaneously, then put the medical pads directly there for the
treatment.
Chord Winder
6
7
Operational Instructions
Maintenance and Storage After Use
Preparation Prior to Use
1. Cleaning the electrodes
1 Battery installation
1) Push off the battery deck cover and open the deck;
2) Insert three 7# batteries, paying attention to polarity.
3) Close the deck cover firmly.
After use, wipe off the dirt on the surface of adhering pads with wet cloth (thin silk
or glabrous woolen cloth) and place them against the chord winder. If the pads are
more than dirty, you can wash them with clean water and regain their stickness after
drying.
If pad is still not adhesive after drying, skin might feel stabbing pain. In this case you
may adopt one or two drops of water to moisturize the pad for better adhesion. But
excessive water shall be avoided which may weaken the adhesion. Cold weather
may affect the adhering force. Adhering pad is renewable. If adhesion becomes too
poor, new pad is available for replacing. To keep the clips clean and dry, you can
wipe them with alcohol.
2 Preparation of electrodes
1) Peel off the smooth film on the adhering pads.
2) Put the adhering pads on the chord winder after use.
3 Placing electrodes
1) Wipe the position of body to be
massaged with wet towel to
remove oil, dirt, sweat and makeup;
2) Stick the electrodes directly onto the skin to be massaged.
3) Treatment can not be effected unless both of the two electrodes are placed onto
the body surface. It is not necessary to place the two electrodes symmetrically.
4) Before treating, you may choose two pieces of medical pads, or choose
acupoint pen with one piece of medical pad, as following picture shows.
8
2. Cleaning the main unit
The main unit and electrodes should be cleaned after use.
Regular cleaning of accessories is necessary. Clean the
main unit and electrodes with soft cloth without
dilutions, patrol or other volatile solutions.
3. Storage
Keep away from moisture, high temperature, direct sunlight and water.
Keep away from children to avoid contrived damage.
Take out the batteries if you will not use it for a certain long time.
9
Acupoint Selection and Treatment for Discomfort
You should choose the acupoints to be treated according
to your symptom. If you just want to have massage to
release fatigue, you may choose the acupoints according
to the acupoint map or just massage the sore place.
However, if you want to treat various diseases, you
should choose the proper acupoints according to the
acupoint selection table or other medical books. Correct
selection of acupoints helps a lot to cure your disease, and wrong one may cause vain
effect or even side effect.
Main Symptom
Accompanying Symptom
Acupoints Selected
Therapy
Neck ache
Reluctant to get up, heavy
head, trance, dizzy
Aching point on neck,
dazhui, jianjing, jianyu
Massage, back
stroke for 15
mins. Massage
whenever aching
Vertebra ache
Humeral callus ache,
swollen shoulder, stiff
shoulder
Aching point on
Massage,
shoulder, jianyu, jianjin, Manipulation,
quchi
Stroke
Arm ache
Swollen arm, heavy and
inertia, arm muscle tension,
difficult to move
Shaohai, quze,
qiemen, yanggu,
yangchi
Abdomen ache
Hard to sleep deeply, getting Qihai, shenque,
zhongwan, juque,
up frequently during night,
weiyu
discomfort in abdomen
Sore waste
Difficult to bent
Fengmen, shenyu,
Back stroke,
dachangyu, weizhong,
Massage, Cupping
chengshan
Sleepy eyes
Difficult to bent
Hegu, yangxi, quchi,
qingming
Nose snuffles
Faint hearing, itching nose,
discomfort
Yingxiang, quchi
Acupuncture
Sore and collap
sing laps
Difficult to climb stairs,
heavy legs, easy to get
fever, difficult toe and ankle
movement, feet numbness
and cold
Shenyu, cichou,
weizhong, zhishi
Massage,
Acupuncture,
Manipulation
Poor complexion
Easy to grow comedo, dry
and itching skin
Hegu, quchi, yingxiang
Acupuncture,
Massage
SYMPTOM: Abdomen Ache
ACUPOINT: Qihai
MODE: Massage
TIME: 15 mins
SYMPTOM: Atrophic Arthritis
ACUPOINT: Waiguan
MODE: Manipulation
TIME: 15 mins
SYMPTOM: Acute Lumbar Sprain
ACUPOINT: Mingmen
MODE: Massage
TIME: 15 mins
SYMPTOM: Body Fitness
ACUPOINT: Guanyuan, Qihai
MODE: Acupuncture
TIME: 15 mins
Massage, Cupping
Massage,
Acupuncture
Massage,
acupuncture,
Manipulation
Just choose one or several acupoint(s) for general discomfort, waist and back ache, and headache.
Not necessarily treating all acupoints as listed above.
10
Acupoint Selection & Relief for Discomfort
SYMPTOM: Arm Ache
ACUPOINT: Chize
MODE: Cupping
TIME: 20 mins
WARNING: Consult with your Physician prior to use.
11
Acupoint Selection & Relief for Discomfort
Acupoint Selection & Relief for Discomfort
SYMPTOM: Cervical Spondylopathy
ACUPOINT: Tianzong
MODE: Cupping
TIME: 25 mins
SYMPTOM: Hypertension
ACUPOINT: Quchi
MODE: Massage
TIME: 20 mins
SYMPTOM: Constipation
ACUPOINT: Dachangshu
MODE: Acupuncture
TIME: 15 mins
SYMPTOM: Impotence
ACUPOINT: Ciliao
MODE: Manipulation
TIME: 15 mins
SYMPTOM: Chronic Lumbar Muscle Strain
ACUPOINT: Yaoyangguan
MODE: Manipulation
TIME: 20 mins
SYMPTOM: Manoxenia
ACUPOINT: Qihai
MODE: Acupuncture
TIME: 30 mins
SYMPTOM: Neck Ache
ACUPOINT: Jianjing
MODE: Massage
TIME: 15 mins
SYMPTOM: Diarrhea
ACUPOINT: Guanyuan
MODE: Manipulation
TIME: 20 mins
SYMPTOM: Cold/Headache
ACUPOINT: Hegu
MODE: Acupuncture
TIME: 15 mins
SYMPTOM: Gastralgia
ACUPOINT: Qimen
MODE: Acupuncture
TIME: 30 mins
WARNING: Consult with your Physician prior to use.
12
SYMPTOM: Insomnia
ACUPOINT: Pishu
MODE: Manipulation
TIME: 20 mins
SYMPTOM: Rheumatic Arthritis
ACUPOINT: Liangqiu
MODE: Manipulation
TIME: 20 mins
WARNING: Consult with your Physician prior to use.
13
Acupoint Selection & Relief for Discomfort
SYMPTOM: Sore Waste
ACUPOINT: Shenshu
MODE: Massage
TIME: 15 mins
Diagram of Palm Reflection Zones & Treatment
SYMPTOM: Stomach Spasm
ACUPOINT: Zhongwan
MODE: Acupuncture
TIME: 30 mins
SYMPTOM: Sore & Collapsing Laps
ACUPOINT: Zusanli
MODE: Acupuncture
TIME: 15 mins
SYMPTOM: Vertebra Ache
ACUPOINT: Dazhui
MODE: Manipulation
TIME: 20 mins
SYMPTOM: Stiff Neck
ACUPOINT: Fengchi
MODE: Cupping
TIME: 20 mins
•
WARNINGS: Consult with your Physician prior to use.
14
Palm Acupoint
• Palm Edge Acupoint
Main Acupoint
15
Troubles and Solutions
Diagram of Palm Reflection Zones & Treatment
Status of the
Product
Cause
Solutions
Battery deck is stained
with foreign objects
Check and remove
Batteries used up or
polarity incorrect
Check the cause and remove
or re-install batteries
Plug inserted in the jack
firmly?
Check and correct connection
between electrode and chord,
chord and jack
Electrode contacting
skin correctly?
Stick the mat firmly onto the
skin
Dirt on mat surface?
Clean or change mat
Oil on skin?
Clean your skin
Batteries used up
Replace batteries
Treated surface
flushing, itching,
or twinging
Skin pathergy against
mat contact
Check skin allergic history. For
slight allergy, change position
or shorten treatment time. For
severe allergy, stop treatment
or take disentilization therapy.
Power can not be
turned on after
automatic stop
with timer
Normal
Turn off the power and turn on
3 seconds later.
No stimulation or
no LCD display
Stimulation
becomes weak or
tingling
Output stops
during treatment
for less than 15
minutes since
use.
SPECIFICATIONS
Power
Frequency
Power consumption
Service life of battery
Dimensions of main unit
Weight
16
AAA X 3 (7# battery, 3 pieces)
1-50 Hz
Less than 180mw
Continuously 45 hours in normal condition.
153X70X18 mm.
About 90g
17