“Grounding for ESD, EMI, and Personal Safety” by Larry Labayen
Transcription
“Grounding for ESD, EMI, and Personal Safety” by Larry Labayen
Grounding ESD Technical Seminar in San Diego April 23, 2013 Copyright © 2013 T O TA L S I T E S O L U T I O N Information contained in this presentation shall not be copied, duplicated or used without the written consent from Lyncole XIT Grounding LLC, a VFC company. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com What Is Grounding? An electrical connection, whether intentional or accidental between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Reasons For Grounding – Personnel safety and equipment protection by providing a path to safely dissipate any unwanted charges or potentials. – Ensure equipment performance and protection – Satisfy manufacture’s warranty 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Electrical Protection Pyramid RF AC Surge Instrumentation Telco Data ESD Lightning Safety GROUNDING 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Earth Resistance The ohmic resistance between the grounding electrode and a remote earth (remote grounding electrode). 1 ft. 10 ft. 40 ft. 80 ft. 200 ft. > 200 ft. 12 Ω 20 Ω 22 Ω 23.8 Ω 24 Ω Remote Earth ∞ 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Typical Earth Resistance Requirements Industry Standard Target Upper Target NFPA 70 NEC 25 Ω Two rods regardless of resistance MIL-HDBK-419 10 Ω IEEE Standard 142 Equipment Dependent Equipment Dependent IEEE Standard 1100 Equipment Dependent Equipment Dependent Motorola Standard R-56 5Ω 10 Ω Telecommunications 5Ω 10 Ω Emerson DeltaV 1Ω 3Ω Essilor 3Ω GE Medical Systems 2Ω 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Grounding System Components Equipment 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Electrical Noise Any unwanted electrical signal which produces undesirable effects in the circuits of the control system in which they occur. Noise Sources Natural Example - Lightning - ESD Incidental - Fault Motors Power switching devices Dissimilar metals Intentional - Two way radio (mobile, handheld) Broadcast (AM, FM, Satellite) Cellphone WiFi 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 25 Grounding Lightning Strike 18,000A Potential Rise will be ~450KV at the site 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 5 Grounding Lightning Strike 18,000A Potential Rise will be ~90KV at the site 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Benefits of a Properly Designed Grounding System – Predictable Results – Improved Personnel Safety – Improved Equipment Reliability – Protection from Lightning/Power Surges – Improved Equipment Performance – Less System Noise – Less Stress on Equipment and Fewer Operating Errors – Improved Power Quality – Meet Mfr’s Warranty Requirements 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Resistivity Basics 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Resistivity Signal Generator ~ 1 Meter Square Earth The resistance of earth to current flow between opposite faces of a cubic earth that is one cubic meter in volume. Measured in Ohms-meter. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Resistivity IS IT The key variable in system design Determines grounding system resistance Changing from site to site Depends on: a. Soil type b. Moisture content c. Electrolytes d. Temperature 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Resistivity Comparison Soil Type Resistivity (ohms-cm) 60 Lynconite II Surface Soil 100 5,000 Clay 200 10,000 5,000 100,000 10,000 1,000,000 Limestone 500 400,000 Shales 500 10,000 2,000 200,000 Sand and Gravel Surface Limestone Sandstone 100,000 Granites, Basalts, etc Decomposed Gneisses 5,000 50,000 Slates, etc 1,000 10,000 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Conditions Affecting Soil Resistivity Moisture Electrolytes 200000 Temperature 12000 80000 70000 160000 140000 120000 100000 80000 Resistivity (ohm-cm) 10000 Resistivity (ohm-cm) Resistivity (ohm-cm) 180000 8000 6000 60000 50000 40000 30000 4000 60000 20000 40000 2000 10000 20000 0 0 1 2 3 4 5 6 7 8 9 101112 Moisture % by Weight 0 0 0.1 1 5 10 20 Added Salt % by Weight of Moisture 23 32 32 50 68 86 104 122 Temperature (deg F) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Resistivity Testing 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 4-Pt. Wenner Method C2 15 ft P2 C1 P1 5 ft 10 ft 0 ft A 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Resistivity Testing 4-Pt. Wenner Method Site Area Direction of Test 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 4-Pt. Wenner Method = 1.915 AR Probe Spacing (Feet) Meter Reading (Ohms) Calculated Resistivity (Ohm-Meter) 5 52.00 497.90 10 19.68 370.87 15 10.16 292.00 20 6.53 250.10 30 4.30 247.04 40 10.80 827.28 60 7.40 850.26 80 5.58 855.60 100 4.44 850.26 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Soil Model 100ft Vs 40ft Test Apparent Resistivity (Ohm-meters) Soil model based on a 100-ft. deep investigation 200 150 100 Soil model based on a 40-ft. deep investigation 50 0 0 50 100 150 Average Inter-Electrode Spacing (feet) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Characteristics of Ground Electrodes 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Spheres of influence Radius [ R ] or Primary Spheres Concentric Shells Rod Length ( L ) Electrode Depth (Length) equals the radius of the effective sphere of influence R = L (uniform soil resistivity) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Spheres of influence – Resistance due to sum of a series of “shells” surrounding the electrode ●●● – Closest “shell” has the smallest circumference. It has the least cross sectional area resulting in higher resistance – Outer “shells” have larger circumference. It has a larger cross sectional area resulting in lower resistance – Lower the resistance of closest “shell”, lower the overall resistance 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Resistance vs. Electrode Length (in a defined space) 300 𝑹= Resistance (Ohms) 250 𝝆 𝟒𝑳 ln[ − 𝟏] 𝟐𝝅𝑳 𝒓 ρ = 100,000 ohm-cm r = 7.94 cm (5/8 in rod ) 200 150 100 50 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Electrode Length (Feet) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Resistance vs. Number of Electrodes (in a defined space) 100 80 60 40 20 0 1 Rod 2 Rods + 3 Rods + 4 Rods + 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Types of Ground Electrodes 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Methods of Grounding and Their Limitations Driven Rods – Copper-clad rods driven into the ground Drawbacks: – Easily affected by the environment, aging, temperature, and moisture. – Resistance increases steadily with age. – Usually damaged during installation. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com “Driven rods have always worked for us...” 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Methods of Grounding and Their Limitations Water Pipes – Large amount of underground metal providing a “theoretically good ground.” Drawbacks: – Difficult to test / impossible to maintain. – Plastic inserts destroy circuit integrity. – Condensation and corrosion are accelerated. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Methods of Grounding and Their Limitations Ground Plates – Thin copper plates placed under poles or supplementing counterpoises. Drawbacks: – Small sphere of influence, higher resistance reading. – Susceptible to environmental changes and corrosion. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Methods of Grounding and Their Limitations Building Steel – Large metallic structure – Disperses fault current equally over large area Drawbacks: – May have little or no connection to earth – May not be electrically continuous – Carries large amounts of electrical noise – Creates multiple “Ground Loops” 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Methods of Grounding and Their Limitations Ufer Grounds / Concrete Encased Electrodes – Copper wire grid incorporated into building concrete foundation. Drawbacks: – Impossible to test and maintain. – Time and gradual removal of moisture can cause change in foundation integrity. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Electrolytic Rod: XIT Grounding System Slotted box cover Protective cover box U-bolt test connection Breather holes Exothermic connection 4/0 copper conductor Electrolytic ground rod Backfill material All copper Non-hazardous earth salts Weep holes Electrolytic roots 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com The XIT Grounding System (Horizontal Shaft) Slotted box cover Protective cover box U-bolt test connection Breather holes Exothermic connection # 6 thru 1000 MCM copper conductor 3’ Electrolytic ground rod Backfill material All copper Weep holes Electrolytic roots 10’ Non-hazardous earth salts 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Resistance Variance Over a Year: XIT Rod -v- Driven Rod 60 50 40 Driven Rod XIT Rod 30 20 10 0 High Low Median Study done by IAEI 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Grounding Calculations 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Earth Ground Resisitivity Nomograph This example reflects a 5 ohm ground resistance with a soil resistivity of 1800 ohms/cm using 5/8 inch diameter copper clad steel rods buried to a 10 ft depth D Directions 1) Select required resistance on R scale 2) Select apparent resistivity on P scale 3) Lay straightedge on R and P scale, and allow to intersect with K scale 4) Mark K scale point 5) Lay straightedge on K scale point and DIA scale and allow to intersect with D scale 6) R Point on D scale will be the depth required for R=Ground Rod resistance on R scale Resistance-Ohms K DIA P P=Soil Resistivity (ohms-cm) D=Rod Depth (feet) DIA= Rod Diameter (in) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Resistance of Single Rod Green Book IEEE-142 (Table 13) 4L R 1 ln 2L a R = Resistance L = Length of Rod ρ = Resistivity a = Radius of rod 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Influence of Resistivity Example: Soil Type: Clay = 1500 ohm-cm 5/8” x 10’ Driven Rod R = 4.963 ohms Soil Type: Sand = 50000 ohm-cm 5/8” x 10’ Driven Rod R = 165.447 ohms 1500 1219.2 1 ln 1915.11 0.794 R 0.78327.337 1 R R 4.963 50000 1219.1 1 ln 1915.11 0.794 R 26.1087.337 1 R R 165.447 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Resistance of Two Rods (Spacing Greater than Length) 4L L2 2 L4 1 2 4 ... R 1 ln 4L a 4 s 5s 3s 1500 7.3367 1 0.19581 0.94167 3830.23 R 2.4814 0.18439 R 2.52122 R ρ = Resistivity (1500 Ohm-cm) L = Length of Rod (304.8cm or 10 ft.) a = Radius of rod (0.794cm or 5/8in.) s = Spacing between rods (609.6cm or 20 ft.) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Resistance of Horizontal Wire (100 Feet of 4/0 AWG Buried 30 Inches Deep) (1500 ohm-cm soil) 4L 4L s s2 s4 ln R ln 2 ... 2 4 4L a s 2 L 16 L 512 L 1500 9.114 3.689 2 0.05 0.000625 0.000000195 19151.15 R 0.0783 10.852 R 0.8499 R ρ = Resistivity (1500 ohm-cm) 2L = Length of Wire (3048cm or 100 ft.) a = Radius of Wire (0.671cm or 0.264 in.) s/2 = Depth of conductor (76.2cm or 30 in.) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Grounding Design 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com ABC ENGINEERING John Smith Date: November 30, 2008 RE: Site # Grounding Option N/A Address: Project #: Acct Mgr.: 080020 Zahid Mitha Engineer: Yellow Brick Road #1 Main Street Anywhere, USA XYZ Communication Julian Hristov These options are conservative calculations of the grounding system, based on testing data provided by ABC Engineering. These designs will provide a stable, system that will be unsusceptible to environmental variables, such as changes in temperature and precipitation, and may improve with time. NUMBER OF ELECTRODES ELECTRODE TYPE TYPE AND SIZE OF GRID PLACEMENT OF ELECTRODES CALCULATED EARTH RESISTANCE Grounding Option 3 K2L-10CS As illustrated (Drawing 1) As illustrated (Drawing 1) < 25 ohms 5 K2L-10CS As illustrated (Drawing 2) As illustrated (Drawing 2) < 10 ohms 8 K2L-10CS As illustrated (Drawing 3) As illustrated (Drawing 3) < 5 ohms Note: Lyncole recommends that the copper conductor be covered with Lynconite II or Lyncole Grounding Gravel™ to protect from corrosive action of the soil and to promote conductivity. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Grounding System Resistance Testing 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Ground System Testing – Why Test Grounds? – Determine Baseline – Validate Construction – Confirm Design Spec Satisfied – Satisfy Warranty Reqs – Ensure Equip Protection & Performance 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Testing Methods − Two Test Methods − Fall Of Potential Test (Three Point/62% Test) − Clamp-On Test 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Fall of Potential Test – Advantage – Recognized As Accurate – Most Commonly Utilized (IEEE 81) – Disadvantages – Results are Frequently Invalid – Requires Isolated Ground System – Requires Large Area; 10X rod length (ideal) or 5X rod length (min) – Time Consuming – Access To Soil 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Fall of Potential Test 25 50-100ft Spacing 20 15 Readings Not Impacted by Spheres of Influence 10 05 Plateau System Resistance Current Probe 00 Spheres of Influence 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Ground System Testing Required Equipment – 3 / 4 Pole Tester – AVO / AEMC – Test Kit – Probes – Conductor – Tape Measure 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Fall-of-Potential Method C1 P1 C2 Ground Rod Under Test P2 Auxiliary Voltage Electrode 1 ft Remote Current Electrode Earth 10%20% 30% 40% 50% 60%70%80% 90% 10 x depth of electrode 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Fall-of-Potential Test Results P2 Distance (%) P2 Distance (Feet) Measured Resistance (ohms) Resistance Change (ohms) 1 1 67.0 10 10 114.5 47.5 20 20 119.6 5.1 30 30 121.3 1.7 40 40 122.2 0.9 50 50 122.5 0.3 60 60 123.1 0.6 70 70 123.7 0.6 80 80 126.6 2.9 90 90 141.8 15.2 100 100 C2 probe 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Fall of Potential – Why 10+ Samples? – Single Point Could Be Misinterpreted – Data must be plotted – Visual Plateau – Confirms Test Validity Measured Resistance (ohms) 150 140 130 120 110 100 90 80 70 60 1 10 20 30 40 50 60 70 80 90 P2 Probe Distance (Feet) 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Ground Resistance Testing Clamp-On Resistance Testing AEMC 3711 Clamp-On Meter – Convenient, Quick, Easy – Does Not Require Disconnecting Equipment – Measures Current on the Ground 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Clamp -On Meter Operation 2 Control Xformers Current Flow R=E/I ??? ohms Current Flow 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Clamp-On Resistance Testing Example R Rx Rn-1 Rn 1 I V Rx R1 R2 R3 Rn-1 Rn 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Clamp-On Meter Operation Utility Neutral Line Parallel Paths NeutralGround Bond Grounding Conductor Series Loop Current Flow R = ??? E/I 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Conclusion − Grounding is the foundation for personnel safety and system performance. − Low impedance to earth minimizes potential rise in event of lightning, fault or heavy load switching. − A good grounding system implementation always starts at the design phase. − Soil resistivity testing is the key variable for grounding design. − Effective, pragmatic and economically sound earth resistance targets is engineered using computer aided grounding design software. − Test the system before commissioning. − Monitor ground system to ensure system performance. 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com Where Grounding Bonds With Science ® 3547 Voyager Street Suite 204 ● Torrance ● CA 90503 ● Tel: 800.962.2610 ● Email: [email protected] ● Web: www.Lyncole.com
Similar documents
Released courtesy of Areva Resources Canada and UEX
sandstone above the SLC but the TAMT inverted results are not as smoothly varying and the conductive halo not as wide. Within the basement, the TAMT inverted results place conductive material aroun...
More information