Figure 1 Prescribed Products

Transcription

Figure 1 Prescribed Products
Lampholder
Plug
Adaptor
Unvented Thermal Storage Type Electric Water Heater
Figure 1 Prescribed Products
Extension Unit
Flexible Cord
Prescribed Products
1. Plugs
2. Adaptors
3. Extension Units
4. Lampholders
5. Flexible Cords
6. Unvented Thermal
Storage Type Electric
Water Heater
Non-Prescribed
Products
All electrical products
designed for
household use other
than the Prescribed
Products.
Essential
Safety
Requirements
(see Schedule 1 of
the Regulation)
Specific
Safety
Requirements
(see Schedule 2 of
the Regulation)
Applicable Safety
Requirements for
Particular Types
of Electrical
Products (see
Section 6 of the
Regulation)
Essential
Safety
Requirements
(see Schedule 1 of
the Regulation)
Figure 2
Applicable Safety Requirements
Compliance
PRESCRIBED PRODUCTS
NON-PRESCRIBED PRODUCTS
}
CLASSIFICATION
OF ELECTRICAL
RECOGNIZED CERTIFICATION BODIES
RECOGNIZED MANUFACTURERS
A)
National
Certification
Bodies under the
CB Scheme
operated by IEC
System for
Conformity
Testing to
Standards for
Safety of
Electrical
Equipment
(IECEE)
Organizations
accredited by
Hong Kong
Laboratory
Accreditation
Scheme
(HOKLAS) or
Hong Kong
Accreditation
Service (HKAS)
Overseas organizations
accredited by schemes
which have mutual
recognition agreements
with HOKLAS or
HKAS
PRODUCT
MANUFACTURERS
Laboratory accredited by:
1) HOKLAS or Overseas Laboratories accredited by
schemes which have mutual recognition agreements with
HOKLAS or HKAS, or
2) Scheme for assessment of testing laboratories as listed in
the International Directory of Laboratory Accreditation
Systems of the International Laboratory Accreditation
Conference; and
B)
Quality assurance certificate to ISO 9002 issued by the
quality system registration bodies under the directory of
}
}
CATEGORIES OF
CERTIFICATION
BODIES
CRITERIA FOR
RECOGNITION
REGISTRATION WITH EMSD
CB test certificates
issued by National
certification bodies
Endorsed
certificates/test
reports issued by
organizations
accredited by
HOKLAS or
HKAS
Endorsed
certificates/test
reports issued by
organizations
accredited by the
above schemes
Declaration of
conformity issued by
recognized
manufacturers
Declaration of
conformity issued by
product
manufacturers
Note: Refer to Section B.8 of the Notes for details
Figure 3
Means to obtain Certificate of Safety Compliance
}
CERTIFICATE
OF SAFETY
COMPLIANCE
Figure 4 CB Test Certificate
The laboratory's name,
address and telephone
number, and the address at
which the test was carried
out if different from the
laboratory's address
The HOKLAS logo and the
laboratory's registration
number
Unique identification
number or code
Date of issue
Page number in the form
shown if more than one
page
The handwritten signature
and typed name of an
approved signatory
A statement about the
laboratory's accreditation
A statement about
reproduction of the report
Figure 5 (page 1 of 2)
HOKLAS Endorsed Test Report
(Prior to formation of HKAS)
The laboratory’s name,
address and telephone
number, and the address
at which the test was
carried out if different from
the laboratory’s address
The HKAS & HOKLAS logos
and the laboratory's
registration number
ABC Testing Limited
23, Testing Avenue, Kowloon, Hong Kong.
Tel: 3995 555 Telex: 9999 HX
Unique identification
number or code
TEST REPORT
Applicant:
Industry Department
36/F., Immigration Tower
7 Gloucester Road
Hong Kong
TEST REPORT No.
PAGE
DATE OF ISSUE:
0001
1 of 7
15 Dec.99
Page number in the form
shown if more than one
page
Date of issue
The handwritten signature
and typed name of an
approved signatory
APPROVED SIGNATORY:
J. LEE
This laboratory is accredited by the Hong Kong Laboratory Accreditation Scheme (HOKLAS)
for specific tests and/or measurements and the results shown in this test report have been
determined in accordance with the laboratory's terms of accreditation. It may not be
reproduced except with prior written approval from the issuing laboratory.
A statement about the
laboratory's accreditation
A statement about
reproduction of the report
Figure 5 (page 2 of 2)
HOKLAS Endorsed Test Report
(After formation of HKAS)
Declaration of Conformity
Ref. No.
We
,
(name of manufacturer)
,
(address)
declare under our sole responsibility that product
,
(name, type or model, lot, batch or serial number, possibly sources and numbers of items)
to which this declaration relates is in conformity with the technical requirements of the
following standard(s) :
(title)
(grade)
(no.)
(year)
(category) (if applicable)
(name of authorized officer)
(title of authorized officer)
(date of issue)
(signature)
(company seal)
Figure 6
Accreditation bodies which have mutual recognition agreement/arrangement with
HOKLAS/HKAS
HOKLAS/HKAS has concluded a number of mutual recognition agreements/ arrangements
with thirty-eight overseas accreditation bodies up to December 2000. They included:
(1) American Association for Laboratory Accreditation (A2LA) of the United States of
America
(2) Accreditation Organisation for Testing Laboratories (BELTEST) of Belgium
(3) Belgian Calibration Organisation (BKO/OBE) of Belgium
(4) Bundesministerium Für Wirtschaftliche Angelegenheiten (BMwA) of Austria
(5) Czech Accreditation Institute (CAI) of Czech Republic
(6) China National Accreditation of Laboratories (CNACL) of the People’s Republic of
China
(7) Chinese National Laboratory Accreditation (CNLA) of Chinese Taipei
(8) Comite Francais d’Accreditation (COFRAC) of France
(9) Danish Accreditation (DANAK) of Denmark
(10) Deutsche Akkreditierungsstelle Chemie GmbH (DAR-DACH) of Germany
(11) Deutsches Akkreditierungssystem Prüfwesen GmbH (DAR-DAP) of Germany
(12) Deutsche Akkreditierungsstelle für Technik e.V. (DAR-DATech) of Germany
(13) Deutscher Kalibrierdienst (DAR-DKD) of Germany
(14) Entidad Nacional de Acreditación (ENAC) of Spain
(15) Finnish Accreditation Service (FINAS) of Finland
(16) International Accreditation New Zealand (IANZ) of New Zealand
(17) International Conference of Building Officials Evaluation Service, Inc. (ICBO ES) of
the United States of America
(18) National Institute of Metrology, Standardization, and Industrial Quality (INMETRO)
of Brazil
(19) Instituto Português da Qualidade (IPQ) of Portugal
(20) Japan Accreditation Board for Conformity Assessment (JAB) of Japan
(21) Japan Calibration Service System (JCSS) of Japan
(22) Japan National Laboratory Accreditation (JNLA) of Japan
(23) Korea Laboratory Accreditation Scheme (KOLAS) of Korea
(24) Norwegian Accreditation (NA) of Norway
Figure 7 (page 1 of 4)
(25) National Accreditation Board (NAB) of Ireland
(26) National Accreditation Board for Testing & Calibration Laboratories (NABL) of India
(27) National Association of Testing Authorities (NATA) of Australia
(28) National Voluntary Laboratory Accreditation Program (NVLAP) of the United States
of America
(29) Raad voor Accreditatie (RvA) of the Netherlands
(30) Singapore Accreditation Council–Singapore Laboratory Accreditation Scheme (SACSINGLAS) of Singapore
(31) South African National Accreditation System (SANAS) of South Africa
(32) Swiss Accreditation Service (SAS) of Switzerland
(33) Standards Council of Canada (SCC) of Canada
(34) Sistema Nazionale di Accreditamento Laboratori (SINAL) of Italy
(35) Servizio di Taratura in Italia (SIT) of Italy
(36) Swedish Board for Accreditation and Conformity Assessment (SWEDAC) of Sweden
(37) United Kingdom Accreditation Service (UKAS) of the United Kingdom
(38) Vietnam Laboratory Accreditation Scheme (VILAS/Stameq) of Viet Nam
The logos of these accreditation bodies are shown on next page.
Figure 7 (page 2 of 4)
Figure 7 (page 3 of 4)
Figure 7 (page 4 of 4)
Sample Warning Label for Electrical Products Designed Solely for Use at a
Voltage of Less Than 200V Alternating Current Single Phase
8 mm
80 mm
警告
WARNING
5 mm
此產品不應直接接駁香港的電力供應系統,
否則可導致人身受傷或財產受損。
This product should not be connected directly
to the electrical supply system in Hong Kong,
otherwise personal injury or damage
to property may result.
5 mm
3 mm
120 mm
Note :
(1) The warning label shall be with red text against a white background;
(2) The warning label shall be fixed durably and conspicuously on the surface
of the packaging of the electrical product, or on the product itself if no
packaging is provided when supplied;
(3) The warning label shall be of a size not less than (A) 120 mm by 80 mm; or
(B) one quarter of the area of the largest surface of the packaging of the
electrical product.
Figure 8
Notes : (1)
(2)
All dimensions are in millimetres
The dimensions shown in this figure are for reference only, please refer to
BS 1363 Part 1 for exact details.
Figure 9 Dimensions of BS 1363 Plug
A
A
H
G
G
F
E
B
D
D
C
DIMENSIONS IN mm
RATED
CURRENT
( AMPERE)
5
15
NOTES: (1)
(2)
A
22.22
28.58
B
C
D
E
F
G
(NOTE 1)
H
(NOTE 2)
19.05
7.04
to
7.09
5.05
to
5.1
14.73
to
15.62
20.5
to
21.39
7.93
27.2
25.4
8.69
to
8.74
7.04
to
7.09
18.49
to
19.38
28.45
to
29.34
9.52
32.3
"G" is the minimum distance between the pins and the periphery of the plug.
"H" is the radius of the maximum permissible plug contour. The radius is concentric with the pitch circle
radius of the pins.
(3)
The dimensions shown in this figure are for reference only. Please refer to BS 546 for exact details.
Figure 10 Dimensions of BS 546 Plug
A
B
D
C
E
F
DIMENSIONS IN mm
A
B
C
D
E
F
16.6
4.98
to
5.02
15.8
to
16.82
1.5
to
1.75
8
to
9
38.3
NOTES: (1)
Unless the plug pins are provided with suitable fixed insulating sleevings, no part of either pin shall
be less than 8 mm from the periphery of the face of the plug.
(2)
The dimensions shown in this figure are for reference only. Please refer to BS 4573 for exact details.
Figure 11 Dimensions of BS 4573 Plug
Dimensions in millimeters
A = insulating collar
B = metal pin
1)
These dimensions shall not be exceeded within a distance of 18 mm from the engagement
face of the plug.
2)
Dimension a is :
18 mm to 19.2 mm in the plane of the engagement faces;
17 mm to 18 mm at the ends of the pins.
3)
This dimension may be increased to 4 mm within a distance of 4 mm from the engagement
face of the plug.
Pin ends shall be rounded, or conical as shown in detail sketch.
The dimensions shown in this figure are for reference only, please refer to
EN 50075 for exact details.
Figure 12 Dimensions of EN 50075 Plug
Test Certificate on Second-Hand Electrical Products
Reference no.:
Part 1
Product(s) Information
Product description
Brand/model no.
Serial no.
Supplier's information
Name
Address
Telephone no.
Date of supply
Business registration no./
Hawker licence no.*
Part 2
(Registered Electrical Worker no#
I,
)
(name)
certify that inspection and testing on the product(s) mentioned in Part 1 have been carried out and the
product(s) is/are* found to be under a safe condition. The details of the inspection and testing are recorded in
the inspection and testing report of ref. no.
.
Signature of qualified person/
registered electrical worker*
Date :
I,
confirm that the second-hand electrical product(s) mentioned
(name of supplier)
in Part 1 has/have* been inspected and tested, and is/are* found to be under a safe condition.
Authorized Signature
/ Company Chop*
Date :
*
#
Delete inappropriate
The inspection & testing should be carried out by a qualified person or registered electrical worker. Enter the
REW no. for inspection & testing carried out by a registered electrical worker.
Figure 13
Inspection and Testing Report on Second-Hand Electrical Products
Reference no.:
1.
Product(s) Information
Product description
Brand/model no.
Serial no.
2.
Inspection and Testing
2.1 Preliminary inspection to identify any abnormalities of the product
□
□
□
□
□
□
Cracked parts
Loose connection
Damaged components
Sign of overheating
Burnt marks
Water marks
Yes
Yes
Yes
Yes
Yes
Yes
□
□
□
□
□
□
Remark@
Remark@
Remark@
Remark@
Remark@
Remark@
No
No
No
No
No
No
Others
2.2 Product is fitted with an appropriate plug that complies with the requirements of the Electrical Products
(Safety) Regulation (e.g. 3-pin plug conforming to BS546 or BS1363 Part 1).
□
Yes
□
The original plug is replaced by the following plug
2.3 Inspection check on the compatibility of the product, its associated flexible cord and plug, and the rating
of its associated fuse.
□
Satisfactory
□
The following part(s) has/have been replaced
Current rating of fuse
2.4
A
Inspection check on the class of product
□
Class I
(earthed)
□
Class II
(double/ reinforced
insulated)
Remark@
Figure 14 (page 1 of 2)
2.5 Earth continuity test for a Class I product
□ Satisfactory
Remark@
Instrument used
Reading
Ohm
2.6 Insulation testing
□ Satisfactory
Remark@
Insulation resistance
Instrument used
Voltage used
M Ohm
2.7 Functional test to ensure that the product operates normally :
Excessive temperature
Unguarded moving parts
Abnormal nois e or operation
Sharp edges
Loosened parts
Exposed live parts
□
□
□
□
□
□
Yes
Yes
Yes
Yes
Yes
Yes
□
□
□
□
□
□
No
No
No
No
No
No
Remark@
Remark@
Remark@
Remark@
Remark@
Remark@
Others
2.8 Other tests (please specify, use separate sheet when necessary)
Inspected & tested by
(Name)
(Registered Electrical Worker no #)
Signature of qualified person/
registered electrical worker*
Date
#
□
Remark@
*
The inspection & testing should be carried out by a qualified person or registered electrical worker. Enter
the REW no. for inspection & testing carried out by a registered electrical worker.
Tick the appropriate box
Record the abnormalities identified and any replacement or repairing work done.
Delete inappropriate
Figure 14 (page 2 of 2)
Importer’s Declaration
Ref. No. DOC123
Page 1 of 2
We
ABC Company Limited
(Name of Supply Agent/ Importer)
Block A, 8th floor, DEF Building, GHI Road, HONG KONG
(Address)
Telephone no. 12345678
Fax no. 87654321
(Telephone & Fax no.)
declare under our sole responsibility that product(s) :
as specified in the Appendix enclosed ( ref. no. DOC123 Page 2 of 2)
to which this declaration relates is/are in conformity with the technical requirements of
the following standard(s) :
as specified in the Appendix enclosed ( ref. no. DOC123 Page 2 of 2)
C. C. Wong
(Name of authorized officer)
Manager
(Title of authorized officer)
1 December 2000
(Date of issue)
(Signature)
(Company seal / chop)
Figure 15 (page 1 of 2)
Ref. No.
DOC123
Page 2 of 2
Name/Type/
Category of
Product
'BRAND'
microwave
ovens
Certificate of safety
compliance /
documentation
issued in support of this
Declaration
Model
Standards
123-M
223-M
567- F
890- G
890- H
IEC 60335-2-25
IEC 60227
BS 1363 Part1
CB test certificate ref.
no. AB - 123
Declaration of
Conformity ref. no.
D001
HOKLAS endorsed test
certificate ref. no.
ABC/0001/96
'BEAUTY'
electric hair
dryers
456-N
456-O
456-P
456-Q
567-N
567-O
567-P
567-Q
CB test certificate ref.
no. DB - 100
IEC 60335-2-23
BS 6500
BS 1363 Part 1
CB test certificate ref.
no. DB - 101
CB test certificate ref.
no. DA - 888
UKAS/NAMAS
endorsed test certificate
ref. no. MAS/0002/01
1 December 2000
(Date of issue)
(Signature)
(Company seal / chop)
Figure 15 (page 2 of 2)

Similar documents