Figure 1 Prescribed Products
Transcription
Figure 1 Prescribed Products
Lampholder Plug Adaptor Unvented Thermal Storage Type Electric Water Heater Figure 1 Prescribed Products Extension Unit Flexible Cord Prescribed Products 1. Plugs 2. Adaptors 3. Extension Units 4. Lampholders 5. Flexible Cords 6. Unvented Thermal Storage Type Electric Water Heater Non-Prescribed Products All electrical products designed for household use other than the Prescribed Products. Essential Safety Requirements (see Schedule 1 of the Regulation) Specific Safety Requirements (see Schedule 2 of the Regulation) Applicable Safety Requirements for Particular Types of Electrical Products (see Section 6 of the Regulation) Essential Safety Requirements (see Schedule 1 of the Regulation) Figure 2 Applicable Safety Requirements Compliance PRESCRIBED PRODUCTS NON-PRESCRIBED PRODUCTS } CLASSIFICATION OF ELECTRICAL RECOGNIZED CERTIFICATION BODIES RECOGNIZED MANUFACTURERS A) National Certification Bodies under the CB Scheme operated by IEC System for Conformity Testing to Standards for Safety of Electrical Equipment (IECEE) Organizations accredited by Hong Kong Laboratory Accreditation Scheme (HOKLAS) or Hong Kong Accreditation Service (HKAS) Overseas organizations accredited by schemes which have mutual recognition agreements with HOKLAS or HKAS PRODUCT MANUFACTURERS Laboratory accredited by: 1) HOKLAS or Overseas Laboratories accredited by schemes which have mutual recognition agreements with HOKLAS or HKAS, or 2) Scheme for assessment of testing laboratories as listed in the International Directory of Laboratory Accreditation Systems of the International Laboratory Accreditation Conference; and B) Quality assurance certificate to ISO 9002 issued by the quality system registration bodies under the directory of } } CATEGORIES OF CERTIFICATION BODIES CRITERIA FOR RECOGNITION REGISTRATION WITH EMSD CB test certificates issued by National certification bodies Endorsed certificates/test reports issued by organizations accredited by HOKLAS or HKAS Endorsed certificates/test reports issued by organizations accredited by the above schemes Declaration of conformity issued by recognized manufacturers Declaration of conformity issued by product manufacturers Note: Refer to Section B.8 of the Notes for details Figure 3 Means to obtain Certificate of Safety Compliance } CERTIFICATE OF SAFETY COMPLIANCE Figure 4 CB Test Certificate The laboratory's name, address and telephone number, and the address at which the test was carried out if different from the laboratory's address The HOKLAS logo and the laboratory's registration number Unique identification number or code Date of issue Page number in the form shown if more than one page The handwritten signature and typed name of an approved signatory A statement about the laboratory's accreditation A statement about reproduction of the report Figure 5 (page 1 of 2) HOKLAS Endorsed Test Report (Prior to formation of HKAS) The laboratory’s name, address and telephone number, and the address at which the test was carried out if different from the laboratory’s address The HKAS & HOKLAS logos and the laboratory's registration number ABC Testing Limited 23, Testing Avenue, Kowloon, Hong Kong. Tel: 3995 555 Telex: 9999 HX Unique identification number or code TEST REPORT Applicant: Industry Department 36/F., Immigration Tower 7 Gloucester Road Hong Kong TEST REPORT No. PAGE DATE OF ISSUE: 0001 1 of 7 15 Dec.99 Page number in the form shown if more than one page Date of issue The handwritten signature and typed name of an approved signatory APPROVED SIGNATORY: J. LEE This laboratory is accredited by the Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific tests and/or measurements and the results shown in this test report have been determined in accordance with the laboratory's terms of accreditation. It may not be reproduced except with prior written approval from the issuing laboratory. A statement about the laboratory's accreditation A statement about reproduction of the report Figure 5 (page 2 of 2) HOKLAS Endorsed Test Report (After formation of HKAS) Declaration of Conformity Ref. No. We , (name of manufacturer) , (address) declare under our sole responsibility that product , (name, type or model, lot, batch or serial number, possibly sources and numbers of items) to which this declaration relates is in conformity with the technical requirements of the following standard(s) : (title) (grade) (no.) (year) (category) (if applicable) (name of authorized officer) (title of authorized officer) (date of issue) (signature) (company seal) Figure 6 Accreditation bodies which have mutual recognition agreement/arrangement with HOKLAS/HKAS HOKLAS/HKAS has concluded a number of mutual recognition agreements/ arrangements with thirty-eight overseas accreditation bodies up to December 2000. They included: (1) American Association for Laboratory Accreditation (A2LA) of the United States of America (2) Accreditation Organisation for Testing Laboratories (BELTEST) of Belgium (3) Belgian Calibration Organisation (BKO/OBE) of Belgium (4) Bundesministerium Für Wirtschaftliche Angelegenheiten (BMwA) of Austria (5) Czech Accreditation Institute (CAI) of Czech Republic (6) China National Accreditation of Laboratories (CNACL) of the People’s Republic of China (7) Chinese National Laboratory Accreditation (CNLA) of Chinese Taipei (8) Comite Francais d’Accreditation (COFRAC) of France (9) Danish Accreditation (DANAK) of Denmark (10) Deutsche Akkreditierungsstelle Chemie GmbH (DAR-DACH) of Germany (11) Deutsches Akkreditierungssystem Prüfwesen GmbH (DAR-DAP) of Germany (12) Deutsche Akkreditierungsstelle für Technik e.V. (DAR-DATech) of Germany (13) Deutscher Kalibrierdienst (DAR-DKD) of Germany (14) Entidad Nacional de Acreditación (ENAC) of Spain (15) Finnish Accreditation Service (FINAS) of Finland (16) International Accreditation New Zealand (IANZ) of New Zealand (17) International Conference of Building Officials Evaluation Service, Inc. (ICBO ES) of the United States of America (18) National Institute of Metrology, Standardization, and Industrial Quality (INMETRO) of Brazil (19) Instituto Português da Qualidade (IPQ) of Portugal (20) Japan Accreditation Board for Conformity Assessment (JAB) of Japan (21) Japan Calibration Service System (JCSS) of Japan (22) Japan National Laboratory Accreditation (JNLA) of Japan (23) Korea Laboratory Accreditation Scheme (KOLAS) of Korea (24) Norwegian Accreditation (NA) of Norway Figure 7 (page 1 of 4) (25) National Accreditation Board (NAB) of Ireland (26) National Accreditation Board for Testing & Calibration Laboratories (NABL) of India (27) National Association of Testing Authorities (NATA) of Australia (28) National Voluntary Laboratory Accreditation Program (NVLAP) of the United States of America (29) Raad voor Accreditatie (RvA) of the Netherlands (30) Singapore Accreditation Council–Singapore Laboratory Accreditation Scheme (SACSINGLAS) of Singapore (31) South African National Accreditation System (SANAS) of South Africa (32) Swiss Accreditation Service (SAS) of Switzerland (33) Standards Council of Canada (SCC) of Canada (34) Sistema Nazionale di Accreditamento Laboratori (SINAL) of Italy (35) Servizio di Taratura in Italia (SIT) of Italy (36) Swedish Board for Accreditation and Conformity Assessment (SWEDAC) of Sweden (37) United Kingdom Accreditation Service (UKAS) of the United Kingdom (38) Vietnam Laboratory Accreditation Scheme (VILAS/Stameq) of Viet Nam The logos of these accreditation bodies are shown on next page. Figure 7 (page 2 of 4) Figure 7 (page 3 of 4) Figure 7 (page 4 of 4) Sample Warning Label for Electrical Products Designed Solely for Use at a Voltage of Less Than 200V Alternating Current Single Phase 8 mm 80 mm 警告 WARNING 5 mm 此產品不應直接接駁香港的電力供應系統, 否則可導致人身受傷或財產受損。 This product should not be connected directly to the electrical supply system in Hong Kong, otherwise personal injury or damage to property may result. 5 mm 3 mm 120 mm Note : (1) The warning label shall be with red text against a white background; (2) The warning label shall be fixed durably and conspicuously on the surface of the packaging of the electrical product, or on the product itself if no packaging is provided when supplied; (3) The warning label shall be of a size not less than (A) 120 mm by 80 mm; or (B) one quarter of the area of the largest surface of the packaging of the electrical product. Figure 8 Notes : (1) (2) All dimensions are in millimetres The dimensions shown in this figure are for reference only, please refer to BS 1363 Part 1 for exact details. Figure 9 Dimensions of BS 1363 Plug A A H G G F E B D D C DIMENSIONS IN mm RATED CURRENT ( AMPERE) 5 15 NOTES: (1) (2) A 22.22 28.58 B C D E F G (NOTE 1) H (NOTE 2) 19.05 7.04 to 7.09 5.05 to 5.1 14.73 to 15.62 20.5 to 21.39 7.93 27.2 25.4 8.69 to 8.74 7.04 to 7.09 18.49 to 19.38 28.45 to 29.34 9.52 32.3 "G" is the minimum distance between the pins and the periphery of the plug. "H" is the radius of the maximum permissible plug contour. The radius is concentric with the pitch circle radius of the pins. (3) The dimensions shown in this figure are for reference only. Please refer to BS 546 for exact details. Figure 10 Dimensions of BS 546 Plug A B D C E F DIMENSIONS IN mm A B C D E F 16.6 4.98 to 5.02 15.8 to 16.82 1.5 to 1.75 8 to 9 38.3 NOTES: (1) Unless the plug pins are provided with suitable fixed insulating sleevings, no part of either pin shall be less than 8 mm from the periphery of the face of the plug. (2) The dimensions shown in this figure are for reference only. Please refer to BS 4573 for exact details. Figure 11 Dimensions of BS 4573 Plug Dimensions in millimeters A = insulating collar B = metal pin 1) These dimensions shall not be exceeded within a distance of 18 mm from the engagement face of the plug. 2) Dimension a is : 18 mm to 19.2 mm in the plane of the engagement faces; 17 mm to 18 mm at the ends of the pins. 3) This dimension may be increased to 4 mm within a distance of 4 mm from the engagement face of the plug. Pin ends shall be rounded, or conical as shown in detail sketch. The dimensions shown in this figure are for reference only, please refer to EN 50075 for exact details. Figure 12 Dimensions of EN 50075 Plug Test Certificate on Second-Hand Electrical Products Reference no.: Part 1 Product(s) Information Product description Brand/model no. Serial no. Supplier's information Name Address Telephone no. Date of supply Business registration no./ Hawker licence no.* Part 2 (Registered Electrical Worker no# I, ) (name) certify that inspection and testing on the product(s) mentioned in Part 1 have been carried out and the product(s) is/are* found to be under a safe condition. The details of the inspection and testing are recorded in the inspection and testing report of ref. no. . Signature of qualified person/ registered electrical worker* Date : I, confirm that the second-hand electrical product(s) mentioned (name of supplier) in Part 1 has/have* been inspected and tested, and is/are* found to be under a safe condition. Authorized Signature / Company Chop* Date : * # Delete inappropriate The inspection & testing should be carried out by a qualified person or registered electrical worker. Enter the REW no. for inspection & testing carried out by a registered electrical worker. Figure 13 Inspection and Testing Report on Second-Hand Electrical Products Reference no.: 1. Product(s) Information Product description Brand/model no. Serial no. 2. Inspection and Testing 2.1 Preliminary inspection to identify any abnormalities of the product □ □ □ □ □ □ Cracked parts Loose connection Damaged components Sign of overheating Burnt marks Water marks Yes Yes Yes Yes Yes Yes □ □ □ □ □ □ Remark@ Remark@ Remark@ Remark@ Remark@ Remark@ No No No No No No Others 2.2 Product is fitted with an appropriate plug that complies with the requirements of the Electrical Products (Safety) Regulation (e.g. 3-pin plug conforming to BS546 or BS1363 Part 1). □ Yes □ The original plug is replaced by the following plug 2.3 Inspection check on the compatibility of the product, its associated flexible cord and plug, and the rating of its associated fuse. □ Satisfactory □ The following part(s) has/have been replaced Current rating of fuse 2.4 A Inspection check on the class of product □ Class I (earthed) □ Class II (double/ reinforced insulated) Remark@ Figure 14 (page 1 of 2) 2.5 Earth continuity test for a Class I product □ Satisfactory Remark@ Instrument used Reading Ohm 2.6 Insulation testing □ Satisfactory Remark@ Insulation resistance Instrument used Voltage used M Ohm 2.7 Functional test to ensure that the product operates normally : Excessive temperature Unguarded moving parts Abnormal nois e or operation Sharp edges Loosened parts Exposed live parts □ □ □ □ □ □ Yes Yes Yes Yes Yes Yes □ □ □ □ □ □ No No No No No No Remark@ Remark@ Remark@ Remark@ Remark@ Remark@ Others 2.8 Other tests (please specify, use separate sheet when necessary) Inspected & tested by (Name) (Registered Electrical Worker no #) Signature of qualified person/ registered electrical worker* Date # □ Remark@ * The inspection & testing should be carried out by a qualified person or registered electrical worker. Enter the REW no. for inspection & testing carried out by a registered electrical worker. Tick the appropriate box Record the abnormalities identified and any replacement or repairing work done. Delete inappropriate Figure 14 (page 2 of 2) Importer’s Declaration Ref. No. DOC123 Page 1 of 2 We ABC Company Limited (Name of Supply Agent/ Importer) Block A, 8th floor, DEF Building, GHI Road, HONG KONG (Address) Telephone no. 12345678 Fax no. 87654321 (Telephone & Fax no.) declare under our sole responsibility that product(s) : as specified in the Appendix enclosed ( ref. no. DOC123 Page 2 of 2) to which this declaration relates is/are in conformity with the technical requirements of the following standard(s) : as specified in the Appendix enclosed ( ref. no. DOC123 Page 2 of 2) C. C. Wong (Name of authorized officer) Manager (Title of authorized officer) 1 December 2000 (Date of issue) (Signature) (Company seal / chop) Figure 15 (page 1 of 2) Ref. No. DOC123 Page 2 of 2 Name/Type/ Category of Product 'BRAND' microwave ovens Certificate of safety compliance / documentation issued in support of this Declaration Model Standards 123-M 223-M 567- F 890- G 890- H IEC 60335-2-25 IEC 60227 BS 1363 Part1 CB test certificate ref. no. AB - 123 Declaration of Conformity ref. no. D001 HOKLAS endorsed test certificate ref. no. ABC/0001/96 'BEAUTY' electric hair dryers 456-N 456-O 456-P 456-Q 567-N 567-O 567-P 567-Q CB test certificate ref. no. DB - 100 IEC 60335-2-23 BS 6500 BS 1363 Part 1 CB test certificate ref. no. DB - 101 CB test certificate ref. no. DA - 888 UKAS/NAMAS endorsed test certificate ref. no. MAS/0002/01 1 December 2000 (Date of issue) (Signature) (Company seal / chop) Figure 15 (page 2 of 2)