LC-R123R4P

Transcription

LC-R123R4P
INDIVIDUAL DATA SHEETS
LC-R123R4P
For main and standby power supplies.
Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
Dimensions (mm)
Terminal type: Faston 187
134 +- 1.5
0.5
67 +- 1
60 +- 1
6
53.2
0.3
133
66.5
Labels will vary, see page 73 for example of labels.
Battery case resin: Standard (UL94HB)
Specifications
12V
3.4Ah
134 mm
67 mm
60 mm
66 mm
1.2 kg
Discharge characteristics (25°C) (Note)
Terminal voltage (V)
Nominal voltage
Rated capacity (20 hour rate)
Length
Width
Dimensions
Height
Total Height
Approx. mass
Characteristics
Temperature
dependency
of capacity
(20 hour rate)
Self discharge
(25°C)
Charge
Method
(Constant
Voltage)
Cycle use
(Repeating
use)
Initial current
Control voltage
Initial current
Trickle use
Control voltage
1
2
4
6 8 10
20
0.34A 0.17A
1.7A 0.85A
3.4A
0
40 60
2
(Minute)
4
6 8 10
20
40
(Hour)
Duration of discharge
1.5A
Approx. 60mΩ
102%
100%
85%
65%
Duration of discharge vs. Discharge current (Note)
30
91%
20
15
82%
10
64%
(Hour)
Internal resistance
3.40Ah
3.00Ah
2.70Ah
2.10Ah
1.36 A or smaller
Duration of discharge
Capacity (note)
(25°C)
20 hour rate (170mA)
10 hour rate (300mA)
5 hour rate (540mA)
1 hour rate (2100mA)
1.5 hour rate discharge
Cut-off voltage 10.5 V
Fully charged battery
(25°C)
40°C
25°C
0°C
-15°C
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
14.4
13.8
13.2
12.6
12.0
11.4
10.8
10.2
9.6
9.0
8.4
7.8
14.5V to 14.9 V
(per 12V cell 25°C)
0.51 A or smaller
13.6V to 13.8V
(per 12V cell 25°C)
25˚C
2
1.5
-15˚C
1
50
40
30
(Minute)
(Note) The above characteristics data are average values obtained within
three charge/discharge cycles, not the minimum values.
40˚C
5
4
3
0˚C
20
10
5
3
30
50
100
300 500
1
(mA)
Discharge current
44
3
5
10
(A)
Sealed Lead-Acid Batteries