pixis: 2k - Princeton Instruments
Transcription
pixis: 2k - Princeton Instruments
SPECTROSCOPY GROUP Now Powered by LightField™ PIXIS: 2K 2048 x 512 The PIXIS series from Princeton Instruments (PI) are fully integrated, low noise cameras designed for quantitative scientific imaging optical spectroscopy applications. Designed utilizing PI’s exclusive XP cooling technology, PIXIS offer thermoelectric cooling down to -75°C, while the all-metal, hermetically sealed design, with the industry’s only lifetime vacuum guarantee, ensures maintenance free operation. Choose either back-illuminated (B/BUV) or eXcelon versions of the 2048 x 512 CCD, for optimized performance from UV to NIR. High QE and ultra low-noise electronics make the PIXIS: 2K series of cameras ideal for demanding, low light applications such as Raman spectroscopy, LIBS, absorbance, emission, fluorescence and reflectance spectroscopy. Princeton Instruments’ eXcelon technology delivers the highest sensitivity in the NIR while suppressing the etaloning that occurs in standard back illuminated CCDs. Dual speed operation at 100kHz or 2MHz allow these cameras to be used for steady state as well as fast kinetics studies. FEATURE BENEFITS eXcelon® technology Increases detector sensitivity while suppressing etalon interference fringes observed in the NIR with conventional back-illuminated devices. Permanent vacuum Our all-metal brazed seals eliminate the outgassing that occurs with epoxy seals and allow us to offer the industry’s only lifetime vacuum guarantee. Deep thermoelectric cooling Low dark noise allows detection of faint signals; CoolCUBE II, a compact room temperature coolant circulator, is available for vibration sensitive environments. Single fused silica vacuum window Minimizes reflection losses from the UV to the NIR; Optional AR coating and wedge windows are available. Optional UV phosphor coating Enhances sensitivity throughout the UV to below 200 nm. 2048 x 512 imaging array, 13.5mm x 13.5mm pixels CCD format provides 6.9 mm height for rapid spectral acquisition; 13.5 mm pixel size offers superior resolution to industry-standard detectors with a 1024 pixel format. 100 kHz and 2 MHz digitization rates Dual-speed digitization allows complete freedom to select between slow operation for low noise and highest SNR or fast operation for rapid image acquisition. Dual amplifiers with software-selectable system gains High sensitivity amplifier reduces noise for weak signals; High capacity amplifier increases dynamic range. USB2.0 data interface Plug-and-play operation with desktops or laptops; Optional fiber optic interface for remote operation; Easy OEM integration. Optional: LightField® (for Windows 8/7, 64-bit) Or WinView/Spec (for Windows 8/7/XP, 32-bit) Flexible software packages for data acquisition, display and analysis; LightField offers intuitive, cutting edge user interface, IntelliCal® and more. PICAM (64-bit) / PVCAM (32-bit) software development kits (SDKs) Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming. Applications: Raman Spectroscopy, LIBS, Absorbance, Emission, Fluorescence and Reflectance Spectroscopy Page 1 of 6 PIXIS: 2K eXcelon Rev. N3.1 SPECTROSCOPY GROUP SPECIFICATIONS Features Dark current @ -75°C (e-/p/sec) PIXIS: 2KB_eXcelon PIXIS: 2KB/BUV Back-illuminated CCD with eXcelon technology. Enhanced sensitivity in the UV and the NIR with low etaloning. Back-illuminated CCD. High sensitivity in both the visible and UV regions. Special BUV version offers the highest sensitivity in the UV region. 0.001 (typical) 0.001 (typical) CCD format 2048 x 512 imaging pixels; 13.5 x 13.5-mm pixels with 100% fill factor Imaging area Optical mount Deepest cooling temperature Thermostating precision Cooling method Spectrometric well capacity: High Sensitivity High Capacity ADC speed/bits System read noise @100 kHz @2 MHz Vertical shift speed 27.6 x 6.9 mm (optically centered) Princeton Instruments Acton spectrometer adapter with optional shutter -75°C guaranteed ±0.05°C Thermoelectric air or liquid cooling (CoolCUBE II required) Non-linearity Software selectable gains Operating systems supported Data interface I/O signals <1% @ 100 kHz 1.5, 3, 6 e- (high sensitivity); 3, 6, 12 e- (high capacity); available at all speeds Windows 8/7/XP (32-bit), Windows 8/7 (64-bit) and Linux USB2.0 Operating environment Certification Dimensions / Weight +5 to +30°C non-condensing CE 16.59 cm (6.53") x 11.81 cm (4.65") x 11.38 cm (4.48") (L x W x H) / 2.27kg (5lbs) 250 ke- (typical), 150 ke- (min) 750 ke- (typical), 600 ke- (min) 100kHz/16-bit and 2MHz/16-bit 3.5 e- rms (typical), 6 e- rms (max) 14 e- rms (typical), 20 e- rms (max) 15.2 msec/row Two MCX to BNC connectors for programmable frame readout, shutter, trigger in All specifications are subject to change. SPECTRAL RATE @ 100 kHz Full Vertical Binning (FVB) @ 2 MHz Full Vertical Binning (FVB) 35 spectra/sec 90 spectra/sec Page 2 of 6 PIXIS: 2K eXcelon Rev. N3.1 SPECTROSCOPY GROUP QE DATA 100% 90% 80% Quantum Efficiency (QE) 70% 60% 50% 40% 30% 20% 10% 0% 250 300 350 400 450 500 2KB_eXcelon 550 600 650 2KB 700 750 800 850 900 950 1000 1050 With optional UV coating 2KBUV Wavelength (nm) NOTE: Graph shows typical Quantum Efficiency (QE) data measured at + 25°C. QE decreases at normal operating temperatures. For the best results for your application, please discuss the specific parameters of your experiment with your sales representative. VACUUM WINDOW AR COATINGS 100 95 NOTES: Standard anti-reflection (AR) coating options shown on graph Designed by Acton Optics, our BBAR coating offers unmatched performance for 400 nm - 1100 nm Custom wedge window options and other AR coatings are also available Contact your local sales representative for more information Transmission (%) 90 85 80 NIR -AR 75 NO -AR 70 MgF2 65 BBAR (400 -1100nm) 60 55 50 200 300 400 500 600 700 800 900 1000 Wavelength (nm) Page 3 of 6 PIXIS: 2K eXcelon Rev. N3.1 SPECTROSCOPY GROUP eXcelon Performance Etalon Oscillations (B_eXcelon vs. B) QE Improvement (B_eXcelon vs. B) 25 0.15 0.1 15 Relative Amplitude QE Improvement (B_eXcelon - B) 20 10 5 0.05 0 -0.05 -0.1 0 -0.15 -5 330 370 410 450 490 530 QE Data measured at +25˚C 570 610 650 690 730 770 810 850 890 930 Wavelength (nm) B_eXcelon provides superior QE over the standard back illuminated (“B”) version in the UV-NIR range. 970 1010 1050 1090 600 650 700 750 800 eXcelon B/I 850 900 950 1000 1050 1100 Wavelength (nm) B_eXcelon provides significantly lower etaloning (unwanted fringes) compared to standard back illuminated (“B”) version. Data taken with white light source through a monochromator, comparing etaloning performance of eXcelon vs. back-illuminated CCDs. Page 4 of 6 PIXIS: 2K eXcelon Rev. N3.1 SPECTROSCOPY GROUP PIXIS DRAWINGS (AIR COOLED) PIXIS with Spectroscopy Mount / 2.27 KG PIXIS with Spectroscopy Mount; with Shutter / 2.27 KG Page 5 of 6 PIXIS: 2K eXcelon Rev. N3.1 SPECTROSCOPY GROUP PIXIS DRAWINGS (LIQUID COOLED) COOLANT INLET/OUT QUICK DISCONNECT FITTINGS 0.203 2 MCX CONNECTORS 0 0.358 0.23 5.77 0.23 5.77 35° TYP. 17.5° TYP. USB 2.0 CONNECTOR 3.600 B.C. 1.851 47.02 0.821 20.85 120° TYP. 0 0 0.450 11.43 0.500 12.70 4.65 2 PIN LEMO CONNECTOR SHUTTER 1/4-20 UNC 9 PIN DIN CONNECTOR POWER 0.593 15.06 0 0.250 6.35 1.780 45.21 6.41 162.9 5.09 129.2 4.24 107.6 0.310 MOUNTING SURFACE TO FRONT SURFACE OF WINDOW 0.600 15.2 CCD TO MOUNT SURFACE 0.06 1.6 0 0 2.14 54.4 0 1.45 36.8 NOTES: 1. WEIGHT 5.5 lbs / 2.49 kg 2. POWER DISSIPATION 110 WATTS AT FULL POWER 3. EXTERNAL WATER CIRCULATOR COOL CUBE II 7567-0002 www.princetoninstruments.com [email protected] TOLL-FREE +1.877.474.2286 | PHONE +1 609.587.9797 Visit the Princeton Instruments website to find a representative in your area. Page 6 of 6 PIXIS: 2K eXcelon Rev. N3.1
Similar documents
pixis: 100 - Princeton Instruments
light applications such as Raman spectroscopy, photo- and electroluminescence, fluorescence and reflectance spectroscopy. Princeton Instruments’ exclusive eXcelon® technology delivers the highest s...
More information