HWAM Monet
Transcription
HWAM Monet
HWAM Monet 09.2008 Installation af vandtank • Installation of boiler Installation von Wassertank • Bruksanvisning Indholdsfortegnelse, dansk Sikkerhedsmæssige lovkrav.................................................................................................................. 5 Tilslutning til centralvarmeanlæg........................................................................................................... 6 Totalopvarmning.................................................................................................................................... 7 Tilslutning til solfangeranlæg................................................................................................................. 8 Tilslutning sammen med jordvarmeanlæg............................................................................................. 9 Tilslutning med automatisk virkende AVTA-ventil................................................................................ 10 Overensstemmelseserklæring............................................................................................................. 11 Table of content, English Instructions for connection of a stove with domestic water heating..................................................... 14 Connection to central heating system................................................................................................. 15 Total heating........................................................................................................................................ 16 Connection to solar collector system................................................................................................... 17 Connection with geothermal energy system....................................................................................... 18 Connection with automatically functioning AVTA valve........................................................................ 19 Inhaltsverzeichnis, Deutsch Vorschriften für den Anschluss eines Ofens mit Brauchwasser-Erwärmung....................................... 21 Anschluss an eine Zentralheizungsanlage.......................................................................................... 22 Alleinheizung....................................................................................................................................... 23 Anschluss mit Erdwärme-Kollektoranlage........................................................................................... 24 Anschluss an Sonnenkollektoranlage.................................................................................................. 25 Anschluss mit Thermosicherung und geschlossener Expansion........................................................ 27 Innehållsförteckning, svensk Säkerhetsmässiga krav enligt lagen.................................................................................................... 28 Anslutning till centralvärmeanläggning................................................................................................ 29 Totaluppvärmning................................................................................................................................ 30 Anslutning till solfångaranläggning...................................................................................................... 31 Anslutning till jordvärmeanläggning..................................................................................................... 32 Anslutning till automatiskt verkande AVTA-ventil................................................................................. 33 Sikkerhedsmæssige lovkrav Dansk Tilslutning af vandtank skal ske i henhold til Arbejdstilsynets publikation nr. 42 "Forskrifter for fyrede varmtvandsanlæg". Heri henvises specielt til afsnit 2 om blandt andet sikkerhedsledning til åben ekspansionsbeholder. Sikkerhedsledningen skal sikre, at ovnens kedel kan komme af med trykket, hvis den på grund af manglende gennemstrømning (for eksempel ved strømsvigt) skulle komme i kog. Hvis vandet i tanken/kedlen koger, vil vandet blive trykket ud gennem sikkerhedsledningen til den åbne ekspansionsbeholder. Ekspansionsbeholderen skal derfor afsluttes ved gulv og afløb, så der ikke kan ske vandskade. Ekspansionsbeholderen skal dimensioneres, så den kan optage udvidelsen af anlæggets vand, når det opvarmes fra 0°C til 100°C. I praksis 4-8%. Ekspansionsbeholderen og sikkerhedsledningen skal være frostsikret. Ekspansionsbeholderens vandstand skal jævnligt kontrolleres. Efter udluftning af anlægget, eller hvis der er kogt vand ud gennem ekspansionsbeholderens overløb, skal vandstanden kontrolleres og eventuelt efterfyldes. 1. HWAM Monet brændeovn med vandkedel. 2. Afgangsstuds (øverst 1"). 3. Sikkerhedsledning, mindste indvendige diameter for stålrør: 21,6 mm, for kobberrør: 19,5 mm. Max. længde: 20 m, max. højde: 10 m. Sikkerhedsledningen må ikke kunne afspærres. 4. Åben ekspansionsbeholder. Skal kunne rumme op til 8% af anlæggets samlede vandindhold. 5. Ø 15 mm hævertbryder. 6. Meldeledning og overløb. Føres til gulv og skal være skråt afskåret. 7. Gulvafløb. 8. Påfyldnings- og aftapningshane. 9. Fremløb 10.Retur. 11.Automatisk luftudlader. T. Termometer, skal kunne måle op til 120° C M. Manometer med rød markering ved højeste vandsøjle. T + M kan være kombineret. Sikkerhedsledningen, som samtidig kan være returledningen til centralfyret, skal udgå fra ovnens topstuds. HWAM Monet's hedeflade udgør 0,28 m og må derfor tilsluttes med dykket sikkerhedsledning. Der skal så blot på det højeste punkt efter afgangsstudsen monteres en automatisk luftudlader (11). Tilslutning til centralvarmeanlæg HWAM Monet kan tilsluttes et nyt eller indkobles på et eksisterende centralvarmeanlæg som en supplerende hjælpekedel. Fremløbsvandet skal tilsluttes ved 4, og afgangsvandet fra brændeovnen skal tilsluttes anlæggets returlinie. En del af fremløbsvandet vil så cirkulere gennem ovnen, hvor det varmes yderligere op, inden det blandes med det koldere returvand. Samtidig sikres det, at der altid er gennemstrømning i ovnen, uanset om varmeanlæggets radiatortermostater skulle være lukkede. Afhængig af varmebehovet kan shuntventilen stilles på "sommerstilling" for hurtig udnyttelse af ovnen til opvarmning af andre rum med radiatorer. Er varmebehovet ikke særligt stort, kan det blive nødvendigt at sætte shunten over mod "vinterstilling" for at inddrage mere vand i cirkulationen. Med shunten i "vinterstilling" opvarmes brugsvand med kedlen. HWAM Monet tilsluttet et centralvarmeanlæg 1. 2. 3. 4. 5. 6. 7. HWAM Monet Udluftning Afgang Tilgang med AVTA-ventil Gulvvarme Radiator Fremløb 8. Retur 9. Retur- og sikkerhedsledning 10.Oliefyr 11.Varmt vand 12.Åben ekspansionsbeholder 13.Shuntventil 14.Pumpe Totalopvarmning Principskitse for totalopvarmning Åben ekspansionsbeholder Varmtvandsbeholder Afgang varmt vand Brændeovnskreds T: Termostat KP77 M1: AT mix-ventil VT: Termostatventil El-stav Tilgang koldt vand HWAM Monet Radiator Pumpe Gulvvarme Gulvvarmekreds Radiatorkreds Brugsvand og rumopvarmning HWAM Monet kan tilsluttes en automatisk virkende mix-ventil og en KP77 termostat til at starte pumperne. Anlægget prioriterer først det varme brugsvand. Derefter inddrages radiatorkredsen til rumopvarmning. Ovnens konvektionssystem afgiver dog hurtigt varme til rummet. Bedst virkning får man, hvis overskudsvarmen veksles over til gulvvarme. Gulvene virker som et varmelager, der langsomt afgiver varmen til rummene. Mix-ventilen sikrer, at vandtanken i HWAM Monet altid er over 50°C. Dette giver en bedre forbrænding og dermed en højere virkningsgrad. Funktion Når der tændes op i brændeovnen, registrerer termostaten (T), som har en føler (F3) i ovnens afgangsstuds, en højere temperatur (over 60°C) og starter cirkulationspumpen. Vekslerspiralen i kombibeholderen opvarmer efter kort tids fyring det varme brugsvand. Når returvandet fra kombibeholderen overstiger mix-ventilens (M1) indstilling, skifter tilgangen efterhånden fra + over til -. Derved inddrages radiatorkredsen i opvarmningen. Gulvvarmekredsen styres af en termoventil (VT), som sikrer, at gulvvarmen ikke overophedes. Når ovnen brænder ud, vil KP77 termostaten slukke pumpen ved 50-55°C. Derved stopper kredsløbet, inden temperaturen er nede på el-stavens ca. 40°C. • Anlægget bør frostsikres med termovæske. • Sikkerhedsledningen fra ovnens afgangsstuds skal altid udføres forskriftsmæssigt og må ikke kunne afspærres. • Der skal altid være gennemstrømning på anlægget, så ovnens vandtank kan komme af med varmen. • Brændeovnskredsen bør være så lille som mulig og være velisoleret. Tilslutning til solfangeranlæg Tilslutning sammen med solfanger HWAM Monet, kombineret med et solfangeranlæg på 4-6 m2 og en ca. 2-300 l kombitank med ekstra spiral og el-stav, er et særdeles godt alternativ til den traditionelle boligopvarmning med oliefyr. I sommerperioden klarer solfangeren opvarmningen af brugsvandet. I koldere perioder, som forår og efterår, suppleres med HWAM Monet, som giver hurtig konvektionsvarme til rummet, og supplerer solfangeren ved at opvarme vandet i den øverste halvdel af kombitanken. I vinterperioden klarer HWAM Monet hele rumopvarmningen dels ved direkte konvektionsvarme, og dels via radiator og gulvvarme. Bedst virkning får man, hvis overskudsvarmen året rundt kan veksles over til gulvvarme. Gulvvarmen virker som et varmelager, der langsomt afgiver varmen til rummene. Solfangerkredsens funktion Ved opvarmning af solfangeren registrerer føleren (F1) en højere temperatur end føleren (F2) i kombibeholderen, og differenstermostaten (DT) starter cirkulationspumpen. Vekslerkappen ligger rundt om kombibeholderens nederste ende. Derved udnyttes solfangeren bedst muligt, også på dage med lille indstråling. Derefter sørger el-staven for den videre opvarmning. Solfangerkredsen skal af hensyn til frostsikring arbejde med termovæske. Brændeovnskredsens funktion Når der tændes op i brændeovnen, registrerer termostaten (F3), som har en føler i ovnens følerstuds, en højere temperatur (over 60°C) og starter cirkulationspumpen. Vekslerspiralen i kombibeholderens top opvarmer efter kort tids fyring de øverste 80 l vand. Når returvandet fra kombibeholderen overstiger mix-ventilens (M1) indstilling, skifter tilgangen efterhånden fra + over til -. Derved inddrages radiatorkredsen i opvarmningen. Gulvvarmekredsen styres af en termoventil (VT), som sikrer, at gulvvarmen ikke overophedes. • • • • Anlægget bør frostsikres med termovæske. Sikkerhedsledningen fra ovnens afgangsstuds skal udføres forskriftsmæssigt og må ikke kunne afspærres. Overskudsvarme fra solfangeren kan ikke fordeles ud på radiatorkredsen. Brændeovnskredsen bør være så lille som mulig og være velisoleret. HWAM Monet tilsluttet sammen med et solfangeranlæg Ekspansionsbeholder DT: Differenstermostat M1: AT Mix-ventil T: Termostat KP 77 Kombibeholder Varmt brugsvand Brændeovnskreds El-stav F3 Solfangerkreds Pumpe Tilgang koldt vand Pumpe Radiator T VT M1 Pumpe 220V DT Trykekspansionsbeholder F2 220V F1 Bypass Radiatorkreds Gulvvarmekreds Gulvvarme Tilslutning sammen med jordvarmeanlæg HWAM Monet kobles på normal vis ind på centralvarmeanlægget mellem fremløbs- og returledningen, således at noget af det varme fremløbsvand opvarmes yderligere, før det blandes med det kolde returvand. Da varmepumpen ikke tåler varmt returvand, skal der før varmepumpen indskydes en termostat og en trevejsventil, så det varme returvand cirkulerer uden om varmepumpen. Funktion Når der fyres i ovnen, registrerer termostatens føler stigende temperatur i returledningen, og trevejsventilen vil lukke vandet uden om varmepumpen og føre det direkte over i fremløbsledningen.Varmepumpen vil således ikke registrere noget forbrug og vil automatisk koble ud. Når ovnen brænder ud, vil temperaturen i returledningen falde, og trevejsventilen vil igen lukke det kolde vand ind i varmepumpen. HWAM Monet tilsluttet sammen med jordvarmeanlæg Ekspansionsbeholder Motorventil M Sikkerhedsledning Termostat T Varmepumpe Afgang Radiator Føler Tilgang AVTA-ventil Jordslanger Fremløb Returledning Føler Tilslutning med automatisk virkende AVTA-ventil 1. Tilgang 3/4" studs. 2. Afgang 1" studs. 3. Følermuffe 3/4" A. Fremløbsledning. B. Returledning og ovnens sikkerhedsledning med forbindelse til åben ekspansion. C. AVTA-ventil. Åbner ved stigende temperatur over 50°C. D. Automatisk luftudlader. E. Termometer. F. Eventuelt manometer. Tilslutningen sikrer sammen med en korrekt fyring den optimale udnyttelse af ovnens vandkedel. Ved at anvende en Danfoss AVTA-ventil 50-90°C kan man sikre en afgangstemperatur fra ovnens vandbeholder på 70-75°C og derved undgå kondensvand på vandtanken. Samtidig sikres en bedre efterforbrænding, idet bålet ikke køles for hårdt ned. AVTA-ventilen monteres på røret til ovnens tilgangsstuds (1) og monteres med føleren gennem Følermuffen ind i ovnens vandkedel. Ventilen skal monteres ifølge fabrikkens anvisninger. Såfremt afgangsrøret og sikkerhedsledningen går nedad, bør der altid monteres en automatisk luftudlader på afgangsrøret. Derved undgås luftlommer, som kan opstå ved overfyring i optændingsfasen. Føres tilslutningen opad fra ovnen, bør der monteres en aftap-ningshane på tilgangsstudsen. Det er forbudt og farligt at blokere sikkerhedsledningen med hane, pumpe eller lignende. 10 Overensstemmelseserklæring Fabrikant: HWAM Heat Design AS Nydamsvej 53 DK – 8362 Hørning Tel.: +45 86 92 18 33 Fax: +45 86 92 22 18 E-mail: [email protected] Erklærer hermed, at Produkt: Type: Nr.: Brændeovn HWAM Monet med vandtank 117 er fremstillet i overensstemmelse med bestemmelserne i følgende direktiver: Reference nr.: Titel: 89/106/EEC Construction Products – CPD samt følgende harmoniserede standarder: Nr: Titel: Udgave: EN 13240 Roomheaters fired by solid fuel 2001 EN 13240/A2 Roomheaters fired by solid fuel 2004 og andre standarder og/eller tekniske specifikationer Nr: Titel: NS 3058 Lukkede vedfyrte ildsteder Røykudslipp NS 3059 Lukkede vedfyrte ildsteder Røykudslipp - Krav Hørning, d. 21. maj 2007 Udgave: Torsten Hvam Pedersen Fabriks- og kvalitetschef 11 Del: 12 Dato Underskrift 13 53-6088 Skorstensfejerpåtegning: Instructions for connection of a stove with domestic water heating The mounting and installation of an HWAM stove with domestic water heating must follow DIN 4751, page 2: 1.This kind of heat generators is only permitted to be used with a kettle temperature not higher than 90°C. 2.The heat exchanger is not permitted to be used for the purpose of heating the domestic water. 3.The flow pressure available for heating the domestic water must account for at least 2 atmospheric pressures. If the water conduit falls down under 2 atmospheric pressures, for example at power failure by your own water supply and at failure by the circulating pump, then the kettle must immediately be taken out of function. 4.Between the domestic water supply and the thermal drain securities no delimiter of the flow mass must be installed. 5.As thermal drain security only a certified unit is allowed to be used, fulfilling the following demands: • Response temperature 95°C. • Flow rate with a sensor temperature of 110°C and a differential pressure at the thermo valve of 1 atmospheric pressure must be at least 200 kg per hour. • The procurement as well as the proper fitting of the required thermo valve is the responsibility of the installation firm. 6.The maximum transport pressure in the joint piece is not permitted to exceed 2,5 mmWS. If this value is exceeded on the assembly place, then the chimney must be provided with a shunt appliance. 7.The equalization vessel must be equipped at its highest point with an automatically functioning exhaust valve. Furthermore, when you fire with solid fuel you have to pay special attention to the following points: a.The water pressure in front of the thermal drain security must account for at least 2 atmospheric pressures, also at open thermal valve. b.It obliges the user to let a competent person control the thermal drain security at least once a year. At this occasion the scales and the slop, if any, should be removed from the thermal drain security. The thermal valve must in this connection be tested on its functionality. Important! The heat connection must always be done by a specialist (heating constructor). Only he knows how to connect the water-leading heat kettle of the stove in a skilled way and according to the DIN norms. 14 As to installations that are not done by a specialist we have to decline every warrantee. As regards professional installation, the person who made the installation is responsible for the construction. Connection to central heating system HWAM Monet can be connected to a new or an existing central heating system as a supplementary auxiliary kettle. The water supply must be connected at 4, and the return water from the woodburning stove must be connected the return line of the system. A part of the water supply will then circulate through the stove where it is heated further, before it is mixed with the colder return water. At the same time it is secured that there is always flow in the stove, no matter if the radiator thermostats of the heating system should be closed. Depending on the need for heat, the shunt valve can be set at ”summer position” for quickly utilization of the stove to heat other rooms with radiators. If the need for heat is not very important it might be necessary to set the shunt towards “winter position” to involve more water in the circulation. With the shunt in “winter position” the kettle heats domestic water. HWAM Monet connected to a central heating system 1. 2. 3. 4. 5. 6. 7. Automatic aeration Vent Outlet Supply by AVTA valve Floor heating Radiator Supply 18. Return 19. Return conduit 10. Oil-fired burner 11. Hot water 12. Expansion tank 13. Shunt valve 14. Pump 15 Total heating Simplified sketch for overall heating Hot water tank Open expansion tank Hot domestic water Woodburning stove circuit A: Woodburning stove circuit B: Radiator circuit C: Floor heating circuit T: Thermostat KP77 M1:AT mix-valve 1: Thermal drain security F3:Sensor Electric heating element T Supply of cold water 1 F3 HWAM Monet Floor heating circuit Safety valve Pump Mix 50°C M1 Floor heating Radiator circuit Outlet Domestic water and heating of rooms HWAM Monet can be connected with an automatically working mix-valve and a KP 77 thermostat intended to start the pumps. The system gives the hot domestic water the highest priority. Then the radiator circuit is involved for heating the rooms. However the convection system of the stove quickly gives off heat to the room. You get the best effect if the surplus heat is converted to floor heat. The floors act as a heat storage slowly giving off the heat to the rooms. The mix-valve secures that the water tank in HWAM Monet is always warmer than 50°C. This gives a better combustion and with that a higher efficiency. Function When you light the woodburning stove, the thermostat (T), having a sensor (F3) in the outlet socket piece of the stove, registers a higher temperature (over 60°C) and starts the circulation pump. The heat exchanger spiral in the multi-purpose tank is after a short heating session heating the hot domestic water. When the return water from the multi-purpose tank exceeds the setting of the mix valve (M1), the supply is little by little changing from + to -. In that way the radiator circuit is involved in the heating. The floor heating circuit is ruled by a thermo valve (VT) securing that the floor heat is not getting superheated. When the stove is burning out the KP77 thermostat closes the pump at 50-55°C. In this way the circuit stops, before the temperature is down on the about 40°C of the electrical stick. • The system should be frost-proof by a thermo fluid. • The stove must have the thermal safeguarding drain mounted according to instructions • There must always be flow in the system so the water tank of the stove can get rid of the heat. • The woodburning circuit should be as little as possible and must be well insulated. 16 Connection to solar collector system Connection together with solar collector HWAM Monet combined with a solar collector system of 4-6 m2 and a multi-purpose tank of about 2-300 litres with extra spiral and electric heating element is a very good alternative to the traditional housing heating with oil-fired burner. During the summer period the solar collector manages the heating of the domestic water. In colder periods, such as spring and autumn, it is supplied with HWAM Monet that gives rapid convection heat to the room, and supplies the solar collector by heating the water in the upper half of the multi-purpose tank. During the winter period, HWAM Monet manages all the heating of the room, partly by direct convection heat and partly via radiator and floor heating. You will get the best effect if the surplus heats all the year can be converted to floor heating. The floor heating act as heat storage, slowly giving off heat to the rooms. The function of the solar collector system By heating the solar collector the sensor (F1) registers a higher temperature than the sensor (F2) in the multi-purpose tank, and the difference thermostat (DT) starts the circulation pump. The heat-exchanging mantle is lying around the bottom edge of the multi-purpose tank. In this way the solar collector is exploited in the best possible way, also on days with little radiation. Thereafter the electric heating element takes care of the further heating. The solar collector system must out of consideration for staying frost-proof work with antifreeze mixture. The function of the woodburning stove circuit When you light up in the woodburning stove, the thermostat (F3) having a sensor in the connecting branch of the woodburning stove registers a higher temperature (over 60°C) and starts the circulation pump. The heat-exchanging spiral in the top of the multi-purpose tank heats after a short heating session the 80 litres of water on top. When the return water from the combination tank exceeds the setting of the mix-valve (M1) the supply little by little changes from + to -. Then the radiator circuit is involved in the heating. The floor heating is ruled by a thermo valve (VT) securing that the floor heating is not getting too hot. • The system should be made frost-proof by an antifreeze mixture. • The safety conduit from the outlet socket piece of the stove must be made according to the regulations and closing off it is not allowed. • The surplus heat from the solar collector cannot be spread out to the radiator circuit. • The woodburning circuit should be as little as possible and must be well insulated. 17 HWAM Monet connected with a solar collector system DT: Differential thermostat M1: AT Mix-ventil T: Thermostat KP 77 Hot water tank Expansion tank Hot service water Woodburing stove circuit Solar collector circuit 220V Electric stick 220V F1 DT T Expansion tank F2 1. Pump Fresh water supply F3 Floor heating circuit 2. M1 Pump Mix 50° Floor heating Bypass Radiator circuit Outlet Connection with geothermal energy system HWAM Monet is connected normally to the central heating system between the supply and the return conduit so that some of the hot supply water is heated further, before it is mixed with the cold return water. As the hot return water is not good for the heat pump, it is necessary to insert a thermostat and a three-way valve, so the hot return water circulates around the pump. Function When heated in the stove, the sensor of the thermostat registers rising temperature in the return conduit, and the three-way valve will close the water around the heat pump and directly to the supply conduit. Therefore the heat pump will not register any consumption and will automatically declutch. When the stove burns out, the temperature in the return conduit will fall, and the three-way valve will once again let the cold water into the heat pump. HWAM Monet connected with geothermal heat system Expansion tank Motor valve M 1. Thermal drain security 2. Safety valve Thermostate Sensor Radiator Pump Heat pump Admission AVTA-valve Supply conduit Earth conductor Outlet Sensor Drain 18 Return conduit Connection with automatically functioning AVTA valve 1. Inlet 3/4" socket piece 2. Outlet 1" socket piece 3. Admission of cooking water 4. Outlet of cooling water 5. Sensing socket A. Supply conduit B. Return conduit C. E.g. AVTA valve 50 - 90°. C. Will open at rising C. temperature D. Automatic aeration E. Thermometer F. Manometer, if any G.Admission with cold water (domestic water) H. Thermal circuit breaker with sensor in connecting branch (5). Opens at 90°C. I. Safety valve J. Outlet of the cooking coil K. Outlet The connection secures together with correct firing the optimal utilization of the water kettle of the stove. By using a Danfoss AVTA valve 50-90°C, you can secure an outlet temperature from the stove’s water tank of 70-75°C, and in this way avoid condensed water at the water tank. At the same time a better secondary combustion is secured, as the fire is not cooled too much down. The AVTA valve is mounted at the pipe to the inlet socket piece of the stove (1) and with the sensor through a 1” cross into to water tank of the stove through the out socket piece (2). The valve is to be mounted in accordance with the instructions of the factory. If the outlet pipe and the security conduit go downwards, there should always be mounted an automatically aeration at the outlet pipe. Like that air pockets are avoided that could arise by overheating in the lighting stage. If the connection is carried upwards from the stove, a drain cock should be mounted at the inlet socket piece. 19 Declaration of Conformity Manufacturer: HWAM Heat Design AS Nydamsvej 53 DK – 8362 Hørning Denmark Tel.: +45 86 92 18 33 Fax: +45 86 92 22 18 E-mail: [email protected] hereby declares that: Product: Type: Wood-burning stove HWAM Monet with watertank was manufactured in accordance with the provisions of the following directive: Reference no. Title: 89/106/EEC Construction Products Directive – CPD and the following harmonised standards: No: Title: Version: EN 13240 EN 13240/A2 Roomheaters fired by solid fuel Roomheaters fired by solid fuel 2001 2004 and other standards and/or technical specifications No: Title: NS 3058 NS 3059 Enclosed wood heaters - Smoke emission Enclosed wood heaters - Smoke emission - requirement Hørning, 21. May 2007 20 Vorschriften für den Anschluss eines Ofens mit Brauchwasser-Erwärmung Die Aufstellung eines HWAM Kaminofens mit Brauchwasser-Erwärmung muss nach DIN 4751, Blatt 2 erfolgen: 1. Derartige Wärmeerzeuger dürfen nur mit einer höchsten Kesselwasservorlauftemperatur von 90°C betrieben werden. 2. Der Wärmetauscher darf nicht zum Zweck der Brauchwasserbereitung benutzt werden. 3. Der für den Brauchwasserbereiter zur Verfügung stehende Fließdruck muss mindestens 2 atü betragen. Sofern der Wasserleitungsdruck unter 2 atü abfällt, z.B. Stromausfall bei Eigenwasserversorgung und Ausfall der Umwälzpumpe, muss der Kessel sofort außer Betrieb genommen werden. 4. Zwischen Brauchwasserzufluss und thermischen Ablaufsicherungen dürfen keine Durchflussmengenbegrenzer eingebaut werden. 5. Als thermische Ablaufsicherung darf nur ein bauteilgeprüftes Ventil verwendet werden, das folgende Anforderungen erfüllt: •Ansprechtemperatur 95°C. •Durchflussleistung bei einer Fühlertemperatur von 110°C und einem Differenzdruck am Thermoventil von 1 atü mindestens 200 kg pro Stunde. •Die Beschaffung und der sachgemässe Einbau des erforderlichen Thermoventils ist Pflicht der Installationsfirma. 6. Der maximale Förderdruck im Verbindungsstück darf 2,5 mmWS nicht überschreiten. Wird dieser Wert am Aufstellungsort überschritten, so ist der Schornstein mit einer Nebenluftvorrichtung auszustatten. 7. Das Ausgleichsgefäß ist an seinem höchsten Punkt mit einer automatisch wirkenden Entlüftung auszurüsten. Ferner ist bei der Verfeuerung von festen Brennstoffen auf folgende Punkte besonders zu achten: a)Der Wasserdruck von der thermischen Ablaufsicherung muss auch bei geöffnetem Thermoventil mindestens 2 atü betragen. b)Der Betreiber ist verplichtet, die thermische Ablaufsicherung mindestens einmal jährlich durch einen Sachkundigen prüfen zu lassen. Hierbei muss gegebenfalls die thermische Ablaufsicherung von Kesselstein und Schmutzwasser gereinigt werden. Das Thermoventil muss hierzu auf seine Funktionsfähigkeit überprüft werden. WICHTIG Der Heizanschluss ist in jedem Falle vom Fachmann zu erstellen (Heizungsbauer). Nur dieser ist in der Lage, den wassergeführten Kamin-Heizkessel fachgerecht und DIN-Normen entsprechend zu installieren. 21 Bei nicht fachgerechter Installation müssen wir jegliche Gewährleistung ablehnen. Für die fachgerechte Installation ist der Errichter der Anlage zuständig. Anschluss an eine Zentralheizungsanlage Der HWAM Monet kann an einer neuen Zentralheizungsanlage angeschlossen werden, oder an einer bereits vorhandenen Anlage angekoppelt werden und an als ergänzenden Hilfskessel dienen. Das Vorlaufwasser muss bei 4 angeschlossen werden, und das Rücklaufwasser des Kaminofens ist an die Retourleitung anzuschließen. Ein Teil des Vorlaufwassers zirkuliert durch den Ofen und erfährt ein zusätzliche Erhitzung, bevor es sich mit dem kälteren Rücklaufwasser vermischt. Dadurch ist gleichzeitig dafür gesorgt, dass im Ofen stets ein Umlauf stattfindet, auch dann, wenn die Heizkörperthermostate der Heizungsanlage geschlossen sein sollten. Je nach Wärmebedarf lässt sich das Wechselventil in „Sommerposition“ bringen. Auf diese Weise kann der Ofen zur schnellen Erwärmung anderer Zimmer mit Heizkörpern genutzt werden. Bei geringerem Wärmebedarf kann es sich als notwendig erweisen, das Wechselventil auf „Winterposition“ zu stellen, um größere Wassermengen in den Umlauf einzubringen. Befindet sich das Wechselventil in „Winterposition“, wird das Nutzwasser im Kessel erhitzt. HWAM Kaminofen an eine Zentralheizungsanlage angeschlossen 1. Entlüftung 2. Thermische Ablaufsicherung 3. Sicherheitsventil 4. Zugang mit AVTA-Ventil 5. Fussbodenwärme 6. Heizkörper 7. Vorlaufleitung 8. Rücklaufleitung 9. Rücklaufleitung 10.Ölbrenner 11.Warmwasser 12.Ausdehnungsgefäß 13.Wechselventil 14.Pumpe 22 Alleinheizung Grundsatzskizze für Alleinheizung mit HWAM Monet und Mix-Ventil Warmwasserboiler Ausdehnungsgefäß T: Thermostat M1:Wechselventil F3: Messfühler VT:Thermostatventil 1. Thermische Ablaufsicherung 2. Sicherheitsventil Warmes Brauchwasser Kaminofenkreis 220V Elektrischer Heizstab T FrischwasserZuführung 1 F3 HWAM Monet Fussbodenheizungskreis 2 VT Pumpe Mix 50° M1 Fussbodenheizung Heizkörperkreis Abfluss Brauchwasser und Raumerwärmung HWAM Monet kann an ein automatisch wirkendes Wechselventil angeschlossen werden und an ein KP77 Thermostat, um die Pumpen in Betrieb zu setzen. Die Anlage bereitet zuerst das warme Brauchwasser. Danach wird der Heizkörperkreis für die Raumerwärmung eingespeist. Das Konvektionssystem des Ofens gibt aber schnell Wärme an die Räumen ab. Die beste Wirkung wird erreicht, wenn die überschüssige Wärme zu Bodenwärme gewechselt wird. Die Fussböden wirken als ein Wärmelager, das langsam die Wärme an die Räume abgibt. Das Wechselventil sichert, dass die Wassertemperatur im HWAM Monet immer über 50°C ist. Dieses ergibt eine bessere Verbrennung und damit einen höheren Wirkungsgrad. Funktion Wenn im Kaminofen geheizt wird, registriert das Thermostat (T), über einen Sensor (F3) im Abgangsstutzen des Ofens, eine höhere Temperatur (über 60°C) und setzt die Umwälzpumpe in Betrieb. Die Wechslerspirale im Kombigefäß erhitzt nach kurzer Feuerzeit das wärme Brauchwasser. Wenn das Rücklaufwasser des Kombigefäßes die Einstellung für das Wechselventil übersteigt (M1), wechselt der Zugang allmählich von + zu -. Damit wird der Heizkörperkreis in die Erwärmung aufgenommen. Der Bodenwärmekreis wird von einem Thermoventil (VT) gesteuert, das sichert, dass die Bodenwärme nicht überhitzt wird. Wenn der Ofen auf brennt, wird das KP77 Thermostat die Pumpe bei 50-55° C ausschalten. Damit hält der Kreislauf inne, bevor die Temperatur zu niedrig für den elektrischen Heizstab wird, etwa 40°C. 23 • Die Anlage sollte mit Frostschutzmittel geschützt sein. • Der Ofen muss mit den Vorschriftsmäßigen thermischen Ablaufsicherungen montiert werden. • In der Anlage muss immer Durchfluss sein, so das der Wassertank des Ofens die Wärme abgeben kann. • Der Kaminofenkreislauf sollte möglichst klein und gut isoliert sein. Anschluss mit Erdwärme-Kollektoranlage HWAM Monet wird auf normale Weise an die Zentralheizungsanlage zwischen den Vorlauf- und Rücklaufleitungen eingekoppelt, so das ein Teil des warmen Vorlaufwassers ein zusätzliche Erhitzung erfährt, bevor es sich mit dem kalten Rücklaufwasser vermischt. Da die Wärmepumpe nicht kaltes Rücklaufwasser verträgt, sind vor der Wärmepumpe einen Thermostat und ein Wechselventil einzuschieben, damit das warme Rücklaufwasser um die Pumpe zirkuliert. Funktion Wenn im Ofen geheizt wird, registriert der Sensor des Thermostats eine steigende Temperatur in der Rücklaufleitung, das Wechselventil wird dann das Wasser um die Wärmepumpe herum leiten und direkt in die Vorlaufleitung einleiten. Die Wärmepumpe registriert damit keinen Verbrauch und schaltet automatisch aus. Wenn der Ofen ausbrennt, wird die Temperatur in der Rücklaufleitung sinken und das Wechselventil wird wieder das kalte Wasser in die Wärmepumpe leiten. HWAM Monet mit einer Erdwärme-Kollektoranlage zusammengeschlossen 1. Thermische Ablaufsicherung 2. Sicherheitsventil Ausdehnungsgefäß Motorventil M Thermostat T Fühler Abgang Pumpe Wärmepumpe Heizkörper Eingang AVTA-Ventil Vorlauf Erdkollektor Fühler Rücklauf Abfluss 24 Anschluss an Sonnenkollektoranlage Anschluss zusammen mit Sonnenkollektor HWAM Monet kombiniert mit einer Sonnenkollektoranlage auf 4-6 m2 und einem 2-300 Liter Kombigefäß mit zusätzlicher Spirale und elektrischem Heizstab ist eine besonders gute Alternative zur traditionellen Wohnungsaufwärmung mit Ölheizung. In der Sommerperiode besorgt der Sonnenkollektor die Erwärmung des Brauchwassers. In kälteren Perioden, wie Frühjahr und Herbst, wird mit HWAM Monet ergänzt, der schnell seine Konvektionswärme zum Raum abgibt, und hilft dem Sonnenkollektor, das Wasser in der oberen Hälfte des KombiGefäßes zu erwärmen. In der Winterperiode besorgt HWAM Monet die ganze Wohnungsaufwärmung, teils durch direkte Konvektionswärme, und teils durch Heizkörper und Bodenwärme. Die beste Wirkung bekommt man, wenn das ganze Jahr die Überschusswärme zu Bodenwärme gewechselt werden kann. Die Bodenwärme funktioniert als ein Wärmelager, das langsam die Wärme zu den Räumen abgibt. Die Funktion des Sonnenkollektorkreises Bei Erwärmung des Sonnenkollektors registriert der Sensor (F1) eine höhere Temperatur als der Sensor (F2) im Kombigefäß, und der Differenzthermostat startet die Umwälzpumpe. Der Wechselmantel liegt rund um den kalten Teil des Kombigefäßes. Dadurch wird der Sonnenkollektor am besten ausgenutzt, auch an Tagen mit kleiner Einstrahlung. Danach sorgt der elekstrische Heizstab für die weitere Erwärmung. Der Sonnenkollektorkreis muss mit Frostschutzmittel geschützt sein. Die Funktion des Kaminofenkreises Wenn im Ofen geheizt wird, registriert der Thermostat (F3), dessen Fühler im Fühlerstutzen des Ofens ist, eine höhere Temperatur (über 60° C) und startet die Umwälzpumpe. Die Wechselspirale im oberen Teil des Kombigefäßes erwärmt nach kurzer Zeit die oberen 80 Liter Wasser. Wenn das Retourwasser vom Kombigefäß die Einstellung des Wechselventils (M1) übersteigt, wechselt der Zugang allmählich von + bis -. Damit wird der Heizkörperkreis in die Erwärmung hineingezogen. Der Fussbodenheizungskreis wird von einem Thermoventil (VT) gesteuert, der sichert, dass die Fussbodenheizung nicht überhitzt wird. • Die Anlage sollte mit Frostschutzmittel geschützt sein. • Der Ofen muss mit den Vorschriftsmäßigen thermischen Ablaufsicherungen montiert werden. • Überschusswärme vom Sonnenkollektor kann nicht auf den Heizkörperkreis nicht verteilt werden. • Der Kaminofenkreislauf sollte möglichst klein und gut isoliert sein. 25 HWAM Monet zusammen mit einer Sonnenkollektoranlage angeschlossen Warmwasserlager Ausdehnungsgefäß Warmes Brauchwasser Kaminofenkreis Elektrischer Heizstab 220V 220V Sonnenkollektorkreis DT T Offenes Ausdehnungsgefäß F2 1. Pumpe Frischwasserzuführung F3 Fussbodenheizungskreis 2. Pumpe F1 Mix 50° Fussbodenheizung M1 Bypass Heizkörperkreis Abfluss T: Thermostat DT: Differenzthermostat 1: Thermische Ablaufsicherung 2: Sicherheitsventil 26 Anschluss mit Thermosicherung und geschlossener Expansion 1.Zugangstutzen 3/4" 2.Abgangstutzen 1" 3.Zugang Kühlwasser 4.Abgang Kühlwasser 5.Fühlermuffe A. Vorlaufleitung. B. Rücklaufleitung. C. Z.B. AVTA-Ventil 50-90°C. Öffnet bei steigender Temperatur. D. Automatischer Luftauslass. E. Thermometer. F. Eventuelles Manometer. G. Zugang mit kaltem Wasser (Brauchwasser). H. Thermosicherung mit Sensor in Sensorstutzen (5). Öffnet bei 90°C. I. Sicherheitsventil. J. Ablauf von Kühlspirale. K. Abgangsrohr. Der Anschluss sichert zusammen mit einer korrekten Feuerung die optimale Ausnutzung des Wasserkessels des Ofens. Durch die Verwendung eines AVTA-Ventils 50-90°C wird eine Abgangstemperatur von 70-75°C gewährleistet und somit wird Kondenswasser auf dem Kessel vermeidet. Gleichzeitig wird eine bessere Nachverbrennung gesichert, da das Feuer nicht zu hart heruntergekühlt wird. Das AVTA-Ventil wird auf das Rohr für den Zugangstutzen des Ofens (1) und mit dem Sensor durch ein 1" Kreuz in den Wasserkessel des Ofens durch den Abgangstutzen (2) montiert. Das Ventil muss nach den Anweisungen der Fabrik montiert werden. Wenn das Abgangsrohr nach unten geleitet wird, sollte ein automatischer Entlüftungshahn auf das Abgangsrohr immer montiert werden. Dadurch werden Lufttaschen, die bei Überhitzung in der Einheizungsphase entstehen können, vermieden. Wenn der Anschluss vom Ofen nach oben geleitet wird, sollte ein Abflusshahn auf den Zugang-stutzen montiert werden. 27 Säkerhetsmässiga krav enligt lagen Anslutning av en vattentank ska ske i enlighet med arbetsinspektionens publikation nr 42 “Föreskrifter för eldade varmvattensystem” och gällande nationella och lokala standarder. I dessa hänvisas särskilt till avsnitt 2 om bland annat en säkerhetsledning till en öppen expansionsbehållare. Säkerhetsledningen ska se till att kaminens värmepanna kan göra sig av med trycket om den kokar på grund av bristande genomströmning (till exempel vid strömavbrott). Om vattnet i tanken/värmepannan kokar trycks vattnet ut genom säkerhetsledningen till den öppna expansionsbehållaren. Expansionsbehållaren ska därför isoleras vid golv och utlopp så att det inte kan uppkomma vattenskada. Expansionsbehållaren ska dimensioneras så att den kan rymma utvidgningen av vattnet i systemet när det värms upp från 0 °C till 100 °C. I praktiken 4-8 %. Expansionsbehållaren och säkerhetsledningen ska vara frostsäkrade. Expansionsbehållarens vattennivå ska kontrolleras regelbundet. När systemet luftats eller om expansionsbehållaren kokat över ska vattennivån kontrolleras och eventuellt fyllas på. 1. HWAM Monet med vattentank. 2. Utgångsrör (överst 1”). 3. Säkerhetsledning, minsta invändiga diameter för stålrör: 21,6 mm, för kopparrör: 19,5 mm. Max. längd: 20 m, max. höjd: 10 m. Det får inte gå att stänga av säkerhetsledningen. Se ev. Arbetarinspektionens publikation nr 42 “Anvisningar för eldade varmvattensystem”. 4. Öppen expansionsbehållare. Ska kunna rymma upp till 8 % av systemets totala vatten-innehåll. 5. Ø 15 mm hävertbrytare. 6. Skvallerledning och överkokning. Dras till golvet och ska vara snett avskuren. 7. Golvutlopp. 8. Påfyllnings- och avtappningskran. 9. Retur. 10. Tillopp. 11. Automatisk luftutsläpp. T. Termometer, ska kunna mäta upp till 120 °C M. Manometer med röd markering vid högsta vattenpelare. T + M kan kombineras. 28 Säkerhetsledningen, som dessutom kan fungera som returledning till centralpannan, ska utgå från kaminens toppanslutning. Värmeytan på HWAM Monet är 0,28 m och därför ska den anslutas med försänkt säkerhetsledning. Sedan behöver du bara montera en automatisk avluftare (11) på den högsta punkten efter utloppsanslutningen. Anslutning till centralvärmeanläggning HWAM Monet kan anslutas till en ny centralvärmeanläggning eller kopplas som extra panna till en befintlig sådan. Framledningsvattnet ska anslutas till 4 och utloppsvattnet från braskaminen ska anslutas till anläggningens returledning. En viss mängd av framledningsvattnet kommer att cirkulera i kaminen och värms upp ytterligare innan det blandas med det svalare returvattnet. Samtidigt säkerställs att det alltid är genomströmning i kaminen – även om värmeanläggningens radiatortermostater skulle vara stängda. Beroende på uppvärmningsbehovet kan shuntventilen ställas in på “sommarinställning”, vilket innebär att kaminen kan utnyttjas för att snabbt värma upp andra rum med element. Om behovet av uppvärmning inte är särskilt stort kan du vara tvungen att ställa in shunten på ”vinterinställning” för att få mer vatten i cirkulation. När shunten står på ”vinterinställning” värms tappvatten upp med pannan. HWAM Monet ansluten till en centralvärmeanläggning 1. 2. 3. 4. 5. 6. 7. HWAM Monet Avluftning Utlopp Inlopp med AVTA-ventil Golvvärme Radiator Framledning 8. Retur 9. Retur- och säkerhetsledning 10.Oljepanna 11.Varmt vatten 12.Öppet expansionskärl 13.Shuntventil 14.Pump 29 Totaluppvärmning Principskiss för totaluppvärmning Öppet expansionskärl Varmvattenbehållare Utlopp varmvatten Kaminkrets T: Termostat KP77 M1: AT blandarventil VT: Termostatventil Elstav Inlopp kallvatten Radiator HWAM Monet Pump Golvvärme Golvvärmekrets Radiatorkrets Tappvatten och rumsuppvärmning HWAM Monet kan anslutas till en automatisk blandarventil och en KP77-termostat som startar pumparna. Anläggningen utnyttjar först det varma tappvattnet. Sedan aktiveras radiatorkretsen för rumsuppvärmning. Kaminens konvektionssystem sprider snabbt värme i rummet. Bäst verkan blir det om du låter överskottsvärmen växla över till golvvärme. Golven fungerar då som en värmebuffert som långsamt avger värme i rummen. Blandarventilen ser till att temperaturen i vattentanken på HWAM Monet alltid ligger över 50 °C. Det ger bättre förbränning och därmed högre verkningsgrad. Funktion När du tänder brasan i kaminen registrerar termostaten (T), som har en sensor (F3) i kaminens utloppsanslutning, att temperaturen höjts (över 60 °C) och startar cirkulationspumpen. Efter en stunds eldning värmer växlarslingan i kombibehållaren upp det varma tappvattnet. När returvattnet från kombibehållaren överskrider blandarventilens (M1) inställning ändras tillförseln efterhand från + till -, vilket leder till att radiatorkretsen omfattas av uppvärmningen. Golvvärmekretsen styrs av en termoventil (VT) som ser till att det inte blir överhettning i golvvärmen. När elden slocknar i kaminen kommer KP77-termostaten att stänga av pumpen vid 50–55 °C, vilket i sin tur leder till att cirkulationen stannar innan temperaturen är nere på elstavens ca 40 °C. • Anläggningen bör skyddas med frostskydd. • Säkerhetsledningen från kaminens utloppsanslutning måste alltid dras enligt gällande föreskrifter och det får inte vara möjligt att spärra den. • Det måste alltid vara cirkulation i anläggningen så att kaminens vattentank kan bli av med värmen. • Kaminkretsen bör vara så liten som möjligt och välisolerad. 30 Anslutning till solfångaranläggning Anslutning till solfångare HWAM Monet som kombineras med en solfångaranläggning på 4–6 m2 och en kombitank på 200–300 l med extra slinga och elstav är ett mycket bra alternativ till vanlig uppvärmning med oljepanna. Under sommaren sköter solfångaren uppvärmningen av tappvattnet. Under de kyligare perioderna, som vår och höst, används dessutom HWAM Monet som snabbt avger konvektionsvärme i rummet och kompletterar solfångaren genom att värma upp vattnet i kombitankens övre halva. Under vintern sköter HWAM Monet all uppvärmning, dels via direkt konvektionsvärme, dels via radiatorer och golvvärme. Bäst verkan blir det om du låter överskottsvärmen växla över till golvvärme året runt. Golvvärmen fungerar som en värmebuffert som långsamt avger värme i rummen. Solfångarkretsens funktion Vid uppvärmning av solfångaren registrerar sensorn (F1) högre temperatur än sensorn (F2) i kombibehållaren och differenstermostaten (DT) startar cirkulationspumpen. Värmeväxlarmanteln ligger runt kombibehållarens nedre del. Därmed utnyttjas solfångaren bäst, även mulna dagar. Sedan sköter elstaven den fortsatta uppvärmningen. På grund av risken för frostskador ska det finnas frostskydd i solfångarkretsen. Kaminkretsens funktion När du tänder brasan i kaminen registrerar termostaten (F3), som har en sensor i kaminens givaranslutning, att temperaturen höjts (över 60 °C) och startar cirkulationspumpen. Efter en stunds eldning värmer växlarslingan i kombibehållarens topp upp de översta 80 l vatten . När returvattnet från kombibehållaren överskrider blandarventilens (M1) inställning ändras tillförseln efterhand från + till -, vilket leder till att radiatorkretsen omfattas av uppvärmningen. Golvvärmekretsen styrs av en termoventil (VT) som ser till att det inte blir överhettning i golvvärmen. • Anläggningen bör skyddas med frostskydd. • Säkerhetsledningen från kaminens utloppsanslutning måste dras enligt gällande föreskrifter och det får inte vara möjligt att spärra den. • Överskottsvärme från solfångaren kan inte överföras till radiatorkretsen. • Kaminkretsen bör vara så liten som möjligt och välisolerad. DT: Differenstermostat M1: AT blandarventil T: Termostat KP 77 HWAM Monet ansluten till solfångaranläggning Öppet expansionskärl Kombibehållare Utlopp varmvatten Kaminkrets Elstav F2 220V F3 F1 220V DT Tryckexpansionskärl Solfångarkrets Pump Inlopp kallvatten Radiator T Pump M1 Golvvärme Pump Golvvärmekrets Bypass 31 Anslutning till jordvärmeanläggning HWAM Monet kopplas som vanligt in mellan centralvärmeanläggningens fram- och returledning så att en del av det varma framledningsvattnet värms upp ytterligare innan det blandas med det kalla returvattnet. Eftersom värmepumpen inte tål varmt returvatten måste en termostat och en trevägsventil monteras framför den så att det varma returvattnet leds förbi. Funktion När du eldar i kaminen registrerar termostatens sensor att temperaturen i returledningen stiger och trevägsventilen leder vattnet förbi värmepumpen och direkt till framledningen. Värmepumpen registrerar alltså inte någon förbrukning och stängs av automatiskt. När elden slocknar faller temperaturen i returledningen och trevägsventilen släpper åter in det kalla vattnet i värmepumpen. HWAM Monet ansluten till jordvärmeanläggning Öppet expansionskärl Säkerhetsledning Motorventil M Termostat T Värmepump Utlopp Radiator Sensor Inlopp AVTA-ventil Jordslangar Framledning Returledning Sensor 32 Anslutning till automatiskt verkande AVTA-ventil 1. Inlopp 3/4” muff. 2. Utlopp 1” muff. 3. Sensormuff 3/4” A. Tilloppsledning. B. Returledning och kaminens säkerhetsledning med anslutning till en öppen expansionsbehållare. C. AVTA-ventil. Öppnar vid stigande temperatur över 50 °C. D. Automatiskt luftutsläpp E. Termometer. F. Eventuell manometer. Tillsammans med korrekt eldning säkrar anslutningen ett optimalt utnyttjande av kaminens vattenpanna. Genom att använda en Danfoss AVTA-ventil 50-90 °C går det att säkerställa en utloppstemperatur från kaminens vattenbehållare på 70-75 °C och därigenom undvika kondensvatten på vattentanken. Detta säkerställer längre livslängd för vattentanken när det gäller korrosion och samtidigt en bättre efterförbränning genom att elden inte kyls ner för snabbt. AVTA-ventilen monteras på röret till kaminens tilloppsmuff (1) och monteras med sensorn genom sensormuffen (2). Ventilen ska monteras enligt anvisningarna från fabriken. Om utloppsröret och säkerhetsledningen går neråt bör det alltid monteras en automatisk avluftare på utloppsröret. Därmed undviks luftfickor som kan uppstå vid överhettning i antändningsfasen. Om anslutningen går uppåt från kaminen bör du montera en tappkran på inloppsanslutningen. Det är förbjudet och farligt att blockera säkerhetsledningen med kran, pump eller liknande. 33 DK-8362 Hørning [email protected] www.hwam.com 36