General and Heavy Duty Safety Switches
Transcription
General and Heavy Duty Safety Switches
• Revised • 07/15/15 General and Heavy Duty Safety Switches Accessories Selection HT63 SAFETY SWITCHES 4 HR612 Class R Fuse Clip Kits Class T Fuse Adapter Kits All General Duty and Heavy Duty Switches are field convertible to accept Class R Fuse Clip Kits. The kits prevent the installation of Class H and K fuses (one kit required per 3-pole switch). All 100-600A, General Duty and 100200Amp and 1200Amp Heavy Duty Switches are field convertible to accept Class T fuses.800A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. Class R Fuse Clip Kits Catalog Number Description GSRK321 HR21 HR612 HR62 HR63 HR64 HR65A HR66A 30A, 240V 30A, 240V 30A, 600V 60A, 600V 100A Kit 200A Kit 400A Kit 600A Kit Kit (GD only) Kit (HD only) Kit/60A, 240V Kit Kit Class J Fusing All 30-600A, 600V and 100-600A,240V fusible Heavy Duty Switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. All 100-600A, 240V fusible General Duty switches can also be field converted to accept Class J fuses. Class J Fuse Kits Catalog Number Description HJ66A 600A, 240V/600V Kit Internal Shield Kits (for fusible switches) Kits provide a clear plastic inner door to prevent accidental contact with live parts. Test probe holes are provided and fuses can be replaced without removal of kit. NEW Class T Fuse Adapter Kitsa Catalog Number Description HT23 HT63 HT24 HT64s HT25A HT65A HT26A HT66A TFAK82 100A, 240V Kit 100A, 600V Kit 200A, 240V Kit 200A, 600V Kit 400A, 240V Kit 400A, 600V Kit 600A, 240V Kit 600A, 600V Kit 1200A, 240V Kit Neutral Kits Standard Neutral Kits can be field installed in General and Heavy Duty Switches. Neutral Kits Switch Ampere Rating Kit Catalog Number 30 GD 30 HD, 60 GD 60, 100 HD, 100 GD 200 400 & 600 800 & 1200 W410190 HN612 HN623 HN64 HN656A HN678 HSK62SSW HSK63SSW 200A HD HSK64SSW s Built to order. Allow 6–8 weeks for delivery. a O ne kit per pole required. 4-18 200% Neutral Kits UL listed 200% Neutrals are available on 100-600A Heavy Duty Switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 200% Neutral Kits Switch Ampere Rating Kit Catalog Number 100 200 HN263 HN264 400 HN656A 600 HN678A Wire Range Line & Load Lugs (Cu/Al) (2) (2) (2) (2) (2) (2) #14-1/0 AWG #6 AWG-300 Kcmil 1/0 AWG-600 Kcmil #6 AWG-300 Kcmil 1/0 AWG-600 Kcmil #6 AWG-300 Kcmil Fuse Puller Kits Fuse Puller Kits Switch Ampere Rating Kit Catalog Number 30A HD HSK61SSW 100A HD HN264 Fuse Puller Kits are field installable in 30-100A Type VBII Heavy Duty Switches (one kit required per 3-pole switch). Internal Shield Kits b 60A HD HN612 Switch Ampere Fuse Puller Kit Rating Catalog Number 030 HP61 HP61 b 060 HP62s 100 HP63s N ot designed for use in Non-metallic 4X safety switches. Not designed for use with Auxiliary Contacts. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Product Category HDSS • Revised • 07/15/15 General and Heavy Duty Safety Switches Accessories Selection HA161234 HA261234 HLC612 Auxiliary Contacts NEW HG261234 Quick Connects Auxiliary Contacts Quick Connects Kit Ampere Rating Switch Ampere Aux. Switch Catalog Number 125V AC Max. 250V AC Max. Horsepower Rating 28V DC Max. 125V AC Max. 250V AC Max. 1/2 1/2 3/4 3/4 1/2 1/2 3/4 3/4 1/2 1/2 3/4 3/4 Catalog Number Description HCQ62 HCQ63 HCQ64 60A 2 wire quick connect kit 100A 2 wire quick connect kit 200A 2 wire quick connect kit With 1 NO & 1 NC Isolated Contacts 30-600 800-1200 HA161234 HA165678 10 10 10 10 7 — With 2 NO & 2 NC Isolated Contacts 30-600 800-1200 HA261234 HA265678 10 10 10 10 7 7 Low Current PLC Type with 1 NO & 1 NC Gold Plated Contacts 30-600 800-1200 HA361234 HA365678 10 10 10 10 7 — Copper Lug Kits Heavy duty switches are UL approved to accept field installed copper lug kits. Copper Lug Kits Switch Ampere Rating 30–60 100 200 400-600 800–1200 Copper Lug Catalog Number Description HLC612 HLC63s HLC64s HCU656An HLC65678 (9) Lugs/Kit #14-4 AWG Cu (9) Lugs/Kit #14-1/0 AWG Cu (9) Lugs/Kit #6 AWG-300 Kcmil Cu (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu s Built to order. Allow 6–8 weeks for delivery. n Purchase field replacement kit along with lugs. Product Category HDSS Isolated Ground Kits Isolated Ground Kits are available on 30-600A Heavy Duty Switches. They are normally used on circuits with a high content of computer or other electronic loading which require a ground which is isolated from the building ground and neutral circuits. The kit includes both isolated and grounded terminals as listed below. Isolated Ground Kits Switch Ampere Rating Catalog Number 30–200 HG261234 2 2 400–600 HG2656A 4 4 Number of Terminals Isolated Grounded Wire Range Per Terminal (Cu/Al) #14-4 AWG 2/0-14 AWG 2/0-6 AWG Equipment Ground Kits Equipment Ground Lug Kits are available for all General and Heavy Duty Switches. They are field installable in Type 1 and Type 3R Switches and are factory installed as standard in Type 4 / 4X and Type 12 and also in all VBII 4&6-pole Switches. Equipment Ground Kits Switch Ampere Rating Catalog Number Number of Terminals 30A GD 60–200 GD 30–200 HD 400 & 600 800–1200 GSGK60 HG61234 HG61234 HG656A HG678 2 2 2 4 8 Wire Range Per Terminal (Cu/Al) #14-8 AWG #14-4 AWG #14-4 AWG 2/0-6 AWG #6 AWG-250 Kcmil Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 4-19 SAFETY SWITCHES They provide two point control power take-off capability and are normally used on two poles on the line side when it is required to have control power available when the switch is in the OFF position. They provide a mounting provision for standard ¼” quick connect terminal. Installed in the line or load side. 30A VBII switches have lugs UL listed to accept (2) wires per pole as standard so a 30A kit is not required. 4 Auxiliary Contacts are available only for Heavy Duty Switches. The auxiliary contacts are available in 1 normally open and 1 normally closed or 2 normally open and 2 normally closed configurations. Siemens offers a PLC Auxiliary Switch (30200A) that has very low resistance for low voltage and current typical in PLC circuits. All auxiliary contacts make after and break before main switch contacts. • Revised • 07/15/15 General and Heavy Duty Hub and Lug Data Interchangeable Hubs Conduit hubs are available for Type 3R, 12 and 4 / 4X applications. 30-200A Type 3R Switches are provided with a conduit hub provision and a removable hub plate on their top rainshed. Conduit Size (inches) Catalog Number a Used On SAFETY SWITCHES 4 Type 3R Cover 3/4 1 1 1/4 Cover 3/4 1 1 1/4 1 1/2 2 2 1/2 2 1/2 3 3 1/2 4 ECHA000 ECHA075 ECHA100 ECHA125 ECHS000 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 ECHV250 ECHV300 ECHV350 ECHV400 b 30A GD Only SSH075 SSH100 SSH125 SSH150 SSH200 SSH250 SSH300 SSH350 SSH400 Field Replacement Kits and Neutral Barrier Kits All Heavy Duty Switches are field convertible for (Crimp) type lugs. When compression lugs are required for 30-100A switches, a neutral barrier kit is required for 1-Phase, 3W or 3-Phase, 4W applications. When compression lugs are required on 400-1200A switches, lug mounting kits are required. 60–200A GD 30–200A HD 400–1200A SSH150 Field Replacement Kits and Neutral Barrier Kits Switch Ampere Catalog Rating Number Type 4/4X 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 Selection 30 60 & 100 400 HCL612 Kit Description Neutral Barrier Kit HCL623 Neutral Barrier Kit HCM65A 240V/600V Fusible Kit 240/600V NonFusible Kit 240V/600V Fusible Kit 240V/600V NonFusible Kit 1 Pole, Compression Lug Mounting Kit 400 HNCM65A 600 HCM66A 600 HNCM66A 800 & 1200e HCL65678n ECHV300 Lugs 30–200A 400–600A Note: 30 thru 200A. Type 3R Switches have removable hub plates on rainshed. 400A and larger Type 3R Switches have no provisions for mounting hubs. Drill or punch hole in the field to accommodate hub size desired. 30 & 60A Switches are suitable for use with 60° or 75°C wire. 100–1200A are suitable for use with 75°C rated wire. ECHS200 Multiple Padlock Accessory A tamper-proof device to provide for multiple padlocking to meet OSHA or plant requirements. Accepts up to 6 1/4” padlocks. Catalog number SL0420. Standard Carton-12. Wire Ranges (Line, Load and Standard Neutral) Switch Ampere Rating Wire Range with Wire Bending Space Per NEC Requirements 30GD 30HD 60hj 100k 200i #14-8 AWG (Cu/AI)f #14-6 AWG (Cu/AI) #14-3 AWG (Cu/AI) #14-1/0 AWG (Cu/Al) #6 AWG-250 Kcmil (Cu/Al) (1) 1/0 AWG-600 Kcmil (Cu/Al) (2) 1/0 AWG-500 Kcmil (Cu/Al) (1) 1/0 AWG-600 Kcmil (Cu/Al) (2) 1/0 AWG-500 Kcmil (Cu/Al) (3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 3/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral 400g 600g 800 1200 4-20 Lug Wire Range #14-6 AWG (Cu/Al) #14-2 AWG (Cu/Al) #14-2 AWG (Cu/Al) #14-1/0 AWG (Cu/Al) #6 AWG-300 Kcmil (Cu/Al) (2) 1/0 AWG-600 Kcmil (Cu/Al) (2) 1/0 AWG-600 Kcmil (Cu/Al) (3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral (4) 1/0 AWG-750 Kcmil (Cu/Al) Line Load (4) 1/0 AWG-750 Kcmil (Cu/Al) neutral Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog SL0420 n Built to order. Allow 3-4 weeks for delivery. Hubs suitable for 3R Switches. Also suitable for Type 12 applications. Neutral Barrier kits are required on 30-100A switches only and only with 1-Phase / 3W or 3-Phase / 4W loads. Compression Lugs mounting kits are required on 400-1200A switches only. d Provides mounting for a single line or load lug. e Provides mounting for (2) compression lugs per phase on line or load. f Line base lugs (only) are UL approved to accept #14-6 CU/Al cable. g Max. wire size for height reduced switches is 500 kcmil (Cu/Al). h All but 60A GD & Compact HD NF switches are also UL approved for #2 Cu/Al conductors. i All 200A Heavy Duty Switches have a wire range & wire bending space for (1) #6-300 Kcmil (Cu/Al). j Also for 30A oversized heavy duty switches. k Also for 60A oversized heavy duty switches. a b c Product Category HDSS & RESI • Revised • 07/15/15 General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights Height Catalog Number *For inches / millimeters conversion, multiply inches by 25.4. 8.13 — 15.45 — 23.15 — 31.07 — 45.81 45.81 45.81 45.81 8.19 — 15.45 — 23.15 — 31.07 — 45.81 45.81 45.81 45.81 45.81 8.19 — 12.31 — 23.15 — 31.07 — 33.96 33.96 17.33 15.45 — 17.33 19.31 17.46 — 19.31 23.16 23.15 — — 8.16 — 15.76 — 23.46 — 31.42 — — — — — 8.16 — 15.76 — 23.46 — 31.42 — — — — — — 8.16 — 12.62 — 23.46 — 31.42 — — — — 15.77 — — — 17.77 — — — 23.46 a Depth With Handle E Box D 5.5 5.16 6.64 6.64 9.64 9.64 14.62 14.61 22.4 22.4 22.4 22.4 7.19 7.19 6.64 6.64 9.64 9.64 14.62 14.61 22.4 22.4 22.4 22.4 22.4 7.19 7.19 6.64 6.64 9.64 9.64 14.62 14.61 22.4 22.4 6.65 6.64 6.64 6.65 9.17 9.15 9.16 9.17 9.65 9.64 9.64 With Handle G Box F 5.94 5.94 8.7 8.7 11.7 11.67 16.68 16.68 23.404 23.404 23.404 23.404 7.69 8.16 8.7 8.7 11.7 11.67 16.68 16.68 23.404 23.404 23.404 23.404 23.404 7.69 7.69 8.71 8.71 11.7 11.67 16.68 16.68 23.404 23.404 9.02 9.01 9.01 9.02 11.47 11.53 11.53 11.47 12.02 12.01 11.97 3 3.13 5.05 5.05 5.05 5.05 6.36 6.36 6.94 6.94 6.94 6.94 3 3.13 5.05 5.05 5.05 5.05 6.36 6.36 6.94 6.94 6.94 6.94 6.94 3 3.13 5.05 5.05 5.05 5.05 6.36 6.36 6.94 6.94 5.32 5.05 5.05 5.32 5.33 5.05 5.05 5.33 5.34 5.05 5.05 5.88 5.88 8.63 8.63 8.63 8.7 10.92 10.92 9.93 9.93 9.93 9.93 5.88 5.88 8.63 8.63 8.63 8.7 10.92 10.92 9.93 9.93 9.93 9.93 9.93 5.88 5.88 8.61 8.61 8.63 8.7 10.92 10.92 9.93 9.93 10.46 10.17 10.17 10.46 10.46 10.17 10.17 10.46 10.46 10.17 10.17 Knockout Diagram S1 S3 S6 S8 S10 S11 S12 S13 S18 S19 S18 S19 S2 S4 S6 S8 S10 S11 S12 S13 S18 S19 S19 S18 S19 S2 S4 S7 S9 S10 S11 S12 S13 S18 S18 — S6 S8 — — S16 S17 — — S10 S11 Shipping Weight (lbs.) 35 (10) 35 (10) 14 14 23 24 47 48 91.1 91.1 95.6 95.6 24 (5) 24 (5) 15 15 25 25 49 50 94.6 94.6 99.6 99.6 99.6 24 (5) 24 (5) 12 13 23 24 46 47 75 77 13 12 13 13 19 18 19 19 24 23 24 K nocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 4-21 SAFETY SWITCHES 7.97 8.07 14.26 14.39 21.95 21.95 29.9 29.9 45.32 45.32 45.32 45.32 7.97 8.07 14.26 14.39 21.95 21.95 29.9 29.9 45.32 45.32 45.32 45.32 45.32 7.97 8.07 11.11 11.11 21.95 21.95 29.9 29.9 33.47 33.47 14.27 14.26 14.39 14.27 16.22 16.26 16.26 16.22 21.96 21.95 21.95 With Rain Shed C 4 GF221N GF221NR GF222N GF222NR GF223N GF223NR GF224N GF224NR GF225NA GF225NRA GF226NA GF226NRA GF321N GF321NR GF322N GF322NR GF323N GF323NR GF324N GF324NR GF325NA GF325NRA GF326NRA GF326NA GF326NRA GNF321 GNF321R GNF322 GNF322R GNF323 GNF323R GNF324 GNF324R GNF325A GNF326A HF221J also HF261J HF221N also HF261 HF221NR also HF261R HF221S also HF261S HF222J also HF262J HF222N also HF262 HF222NR also HF262R HF222S also HF262S HF223J also HF263J HF223N also HF263 HF223NR also HF263R Box A Width With Door B • Revised • 07/15/15 General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights SAFETY SWITCHES 4 Height Catalog Number HF223S also HF263S HF224J HF224N HF224NR HF224S HF225NRA HF225NA HF226NA HF226NRA HF227N HF227NR HF228N HF228NR HF365A HF365JA HF365RA HF365SA HF366A HF366JA HF366RA HF366SA HF321J HF321N HF321NR HF321S, SS HF322J HF322N HF322NR HF322S, SS HF323J HF323N HF323NR HF323S, SS HF324J HF324N HF324NR HF324S, SS HF325JA HF325NA HF325NRA HF325SA HF326JA HF326NA HF326NRA HF326SA HF327J HF327N HF327NR HF327S HF328N HF328NR HF361, PV, PVPG HF361J, JW HF361L HF361N HF361NR HF361R, RPV, RPVPG HF361RL, RW HF361S, SS, SSW, SW HF362, PV, PVPG Box A 21.96 29.96 29.9 29.9 29.96 45.32 45.32 45.32 45.32 66.67 66.67 66.67 66.67 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 14.27 14.26 14.39 14.27 16.27 16.26 16.26 16.27 21.96 21.95 21.95 21.96 29.96 29.9 29.9 21.96 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 66.67 66.67 66.67 66.67 66.67 66.67 14.26 14.27 16.26 14.26 14.39 14.39 16.26 14.27 16.26 Width With Door B 23.16 31.07 31.07 — 31.07 45.81 45.81 45.81 45.81 67.16 — 67.16 — 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 17.33 15.45 — 17.33 19.31 17.46 — 19.31 23.16 23.15 — 23.16 31.07 31.07 — 31.07 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 67.16 67.16 — 67.16 67.16 — 15.45 17.33 17.46 15.45 — — — 17.33 17.46 *For inches / millimeters conversion, multiply inches by 25.4. 4-22 With Rain Shed C — — — 31.42 — — — — — — 67.74 — 67.74 — — — — — — — — — — 15.77 — — — 17.77 — — — 23.46 — — — 31.42 — — — — — — — — — — — 67.74 — — 67.74 — — — — 15.77 15.77 17.77 — — a Box D 9.65 14.62 14.62 14.61 14.62 22.4 22.4 22.4 22.4 38.4 38.4 38.4 38.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 6.65 6.64 6.64 6.65 9.17 9.15 9.16 9.17 9.65 9.64 9.64 9.65 14.62 14.62 14.61 14.62 22.4 22.4 22.4 22.4 22.4 22.4 22.4 22.4 38.4 38.4 38.4 38.4 38.4 38.4 6.64 6.65 9.15 6.64 6.64 6.64 9.16 6.65 9.15 Depth With Handle E 12.02 16.95 16.98 16.99 16.95 23.404 23.404 23.404 23.404 39.96 39.96 39.96 39.96 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 9.02 9.01 9.01 9.02 11.47 11.53 11.53 11.47 12.02 12.01 11.97 12.02 16.95 16.98 16.99 16.95 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 39.96 39.96 40.25 39.96 39.96 40.25 9.01 9.02 11.53 9.01 9.01 9.01 11.53 9.02 11.53 Box F K nocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 5.34 6.63 6.36 6.36 6.63 6.94 6.94 6.94 6.94 9.24 9.24 9.24 9.24 6.94 6.97 6.94 7.34 6.94 6.97 6.94 7.34 5.32 5.05 5.05 5.32 5.33 5.05 5.05 5.33 5.34 5.05 5.05 5.34 6.63 6.36 6.36 6.63 6.97 6.94 6.94 7.34 6.97 6.94 6.94 7.34 9.24 9.24 9.24 9.24 9.24 9.24 5.05 5.32 5.05 5.05 5.05 5.05 5.05 5.32 5.05 With Handle G 10.46 12.58 12.33 12.33 12.58 9.93 9.93 9.93 9.93 14.68 14.68 14.68 14.68 9.93 10.05 9.93 10.347 9.93 10.05 9.93 10.347 10.46 10.17 10.17 10.46 10.46 10.17 10.17 10.46 10.46 10.17 10.17 10.46 12.58 12.33 12.33 12.58 10.05 9.93 9.93 10.347 10.05 9.93 9.93 10.347 14.68 14.68 14.68 14.68 14.68 14.68 10.17 10.46 10.17 10.17 10.17 10.17 10.17 10.46 10.17 Knockout Diagram — — S12 S13 — S19 S18 S18 S19 — — — — S18 — S19 — S18 — S19 — — S6 S8 — — S16 S17 — — S10 S11 — — S12 S13 — — S18 S19 — — S18 S19 — — — — — — — S6 — S16 S6 S8 S8 S17 — S16 Shipping Weight (lbs.) 24 48 47 48 48 91.1 91.1 95.6 95.6 360 362 362 364 93 93 93 93 98 98 98 98 14 14 15 14 20 19 20 20 25 25 26 25 49 49 50 49 93 94.6 94.6 93 98 99.6 99.6 98 367 380 383 367 382 385 14 14 19 14 15 15 20 15 19 • Revised • 07/15/15 General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights Height a Depth With Handle E 11.47 11.53 11.53 11.53 11.97 11.47 12.01 12.02 12.01 11.97 11.97 12.02 16.98 16.95 16.98 16.99 16.99 16.95 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 23.404 39.96 39.96 39.96 40.25 40.25 39.96 39.96 39.96 40.25 40.25 23.404 23.404 23.404 23.404 23.404 23.404 9.01 9.02 9.01 11.53 9.02 11.53 11.47 11.53 11.97 11.47 12.01 12.02 11.97 12.02 16.98 16.95 16.99 16.95 Box F 5.33 5.05 5.05 5.05 5.05 5.33 5.05 5.34 5.05 5.05 5.05 5.34 6.36 6.63 6.36 6.36 6.36 6.63 6.94 6.97 6.94 6.94 6.94 7.34 6.94 6.97 6.94 6.94 6.94 7.34 9.24 9.24 9.24 9.24 9.24 9.24 9.24 9.24 9.24 9.24 6.97 6.94 7.34 7.34 6.97 6.94 5.05 5.56 5.05 5.05 5.56 5.05 5.33 5.05 5.05 5.33 5.05 5.34 5.05 5.34 6.36 6.63 6.36 6.63 With Handle G 10.46 10.17 10.17 10.17 10.17 10.46 10.17 10.46 10.17 10.17 10.17 10.46 12.33 12.58 12.33 12.33 12.33 12.58 9.93 10.05 9.93 9.93 9.93 10.347 9.93 10.05 9.93 9.93 9.93 10.347 14.68 14.68 14.68 14.68 14.68 14.68 14.68 14.68 14.68 14.68 10.05 9.93 10.347 10.347 10.05 9.93 10.17 10.46 10.17 10.17 10.46 10.17 10.46 10.17 10.17 10.46 10.17 10.46 10.17 10.46 12.33 12.58 12.33 12.58 Shipping Knockout Weight Diagram (lbs.) — 20 S16 19 S17 20 S17 20 S11 25 — 20 S10 24 — 25 S10 25 S11 26 S11 25 — 25 S12 48 — 49 S12 49 S13 48 S13 49 — 49 S18 93 — 93 S18 94.6 S19 94.6 S19 93 — 93 S18 98 — 98 S18 99.6 S19 99.6 S19 98 — 98 — 380 — 380 — 382 — 386 — 382 — 380 — 383 — 385 — 388 — 385 — 75 S19 75 — 75 — 77 — 77 S19 77 S7 12 — 13 S9 13 S17 20 — 13 S16 18 — 19 S17 19 S11 24 — 19 S10 23 — 24 S11 24 — 24 S12 46 — 47 S13 47 — 47 K nocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 4-23 SAFETY SWITCHES *For inches / millimeters conversion, multiply inches by 25.4. With Rain Shed Box C D — 9.17 — 9.15 17.77 9.16 17.77 9.16 23.46 9.64 — 9.17 — 9.64 — 9.65 — 9.64 23.46 9.64 23.46 9.64 — 9.65 — 14.62 — 14.62 — 14.62 31.42 14.61 31.42 14.61 — 14.62 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 38.4 — 38.4 — 38.4 67.74 38.4 67.74 38.4 — 38.4 — 38.4 — 38.4 67.74 38.4 67.74 38.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 22.4 — 6.64 — 6.65 12.63 6.64 17.77 9.16 — 6.65 — 9.15 — 9.17 17.77 9.16 23.46 9.64 — 9.17 — 9.64 — 9.65 23.46 9.64 — 9.65 — 14.62 — 14.62 31.42 14.61 — 14.62 4 Catalog Number HF362J, JW HF362N HF362NR HF362R, RPV, RPVPG, RW HF362RL HF362S, SS, SSW, SW HF363, PV, PVPG HF363J, JW HF363N HF363NR HF363R, RPV, RPVPG HF363S, SS, SSW, SW HF364, PV, PVPG HF364J, JW HF364N HF364NR HF364R, RPV, RPVPG HF364S, SS, SSW, SW HF365A HF365JA, HF365JWA HF365NA HF365NRA HF365RA HF365SA, HF365SWA HF366A HF366JA, HF366JWA HF366NA HF366NRA HF366RA HF366SA HF367 HF367J HF367N HF367NR HF367R HF367S HF368, J, S HF368N HF368NR HF368R HNF365JA HNF365RA HNF365SA HNF366SA HNF366JA HNF366RA HNF361, PV, PVPG also HNF261 & HNF362H HNF361J, JW also HNF261J & HNF362JH HNF361R, RPV, RPVPG also HNF261R & HNF362RH HNF361RL HNF361S, SS, SSW, SW also HNF261S & HNF362SH HNF362, PV, PVPG also HNF262 HNF362J, JW also HNF262J HNF362R, RPV, RPVPG also HNF262R HNF362RL HNF362S, SS, SSW, SW also HNF262S HNF363, PV, PVPG also HNF263 HNF363J, JW also HNF263J HNF363R, RPV, RPVPG also HNF263R HNF363S, SS, SSW, SW also HNF263S HNF364, PV, PVPG HNF364J, JW HNF364R, RPV, RPVPG HNF364S, SS, SSW, SW Box A 16.27 16.26 16.26 16.26 21.95 16.27 21.95 21.96 21.95 21.95 21.95 21.96 29.9 29.96 29.9 29.9 29.9 29.96 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 45.32 66.67 66.67 66.67 66.67 66.67 66.67 66.67 66.67 66.67 66.67 45.32 33.47 33.47 33.47 45.32 33.47 11.11 11.12 11.11 16.26 11.12 16.26 16.27 16.26 21.95 16.27 21.95 21.96 21.95 21.96 29.9 29.96 29.9 29.96 Width With Door B 19.31 17.46 — — — 19.31 23.15 23.16 23.15 — — 23.16 31.07 31.07 31.07 — — 31.07 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 45.81 67.16 67.16 67.16 — — 67.16 67.16 67.16 — — 45.81 33.96 33.96 33.96 45.81 33.96 12.31 14.14 — — 14.14 17.46 17.46 — — 17.46 23.15 23.16 — 23.16 31.07 31.07 — 31.07 • Revised • 07/15/15 General and Heavy Duty Safety Switches Dimensions Safety Switch Dimensions (Inches)* & Shipping Weights Catalog Number HNF365JA HNF365JWA HNF365RA HNF365SA, HNF365SWA HNF366JA HNF366RA HNF366SA HNF367, J HNF367R HNF367S HNF368, J, S HNF368R LF111N LF111NR LF211N LF211NR LNF222R Box A 45.32 45.32 33.47 33.47 45.32 33.47 33.47 54.67 54.67 54.67 54.67 54.67 7.97 8.07 7.97 8.07 8.07 Width With Door B 45.81 45.81 33.96 33.96 45.81 33.96 33.96 55.16 — 55.16 55.16 55.16 8.13 — 8.13 — — With Rain Shed C — — — — — — — — 55.7 — — — — 8.16 — 8.16 8.16 Box D 22.4 22.4 22.4 22.4 22.4 22.4 22.4 38.4 38.4 38.4 38.4 38.4 5.5 5.16 5.5 5.16 5.16 Depth With Handle E 23.404 23.404 23.404 23.404 23.404 23.404 23.404 39.96 40.25 39.96 39.96 40.25 5.94 5.94 5.94 5.94 5.94 Box F 6.97 6.97 6.94 7.34 6.97 6.94 7.34 9.24 9.24 9.24 9.24 9.24 3 3.13 3 3.13 3.13 With Handle G 10.05 10.05 9.93 10.347 10.05 9.93 10.347 14.68 14.68 14.68 14.68 14.68 5.38 5.38 5.38 5.38 5.38 Knockout Diagram — — S19 — — S19 — — — — — — S2 S3 S1 S3 S5 SAFETY SWITCHES 4 Height Type 1 or 3R 30A GD Type 1 or 3R 60-200A GD, 30-200A HD Type VBII Type 1 or 3R 400-1200A Type VBII (GD & HD) Type 4/4X or 12 400-1200A HD Type VBII *For inches / millimeters conversion, multiply inches by 25.4. 4-24 a K nocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Type 4/4X or 12 30-200A HD Type VBII Shipping Weight (lbs.) 75 75 75 75 77 77 77 302 304 302 305 307 35 (10) 35 (10) 35 (10) 35 (10) 35 (10) General and Heavy Duty Safety Switches Knockout Diagrams Type 1 & 3R Enclosures 4 SAFETY SWITCHES Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S8 Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S9 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in. 1 0.25 dia. K.O. 2 K.O.'s for Conduit 0.75, 1 in. 5 K.O.'s for Conduit 0.50, 0.75, 1 in. 1 0.25 dia. K.O. *For inches / millimeters conversion, multiply inches by 25.4. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 4-25 General and Heavy Duty Safety Switches • Revised • 07/15/15 Knockout Diagrams SAFETY SWITCHES 4 Type 1 & 3R Enclosures *For inches / millimeters conversion, multiply inches by 25.4. 4-26 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Special Application Safety Switches Dimension Drawings Non-Metallic Dimensions Non-Metallic 4 H W D A B C E F G J HF321NX HF322NX HF361NXa HF362NXa HF363NXa HF364NXa 18.75 18.75 18.75 18.75 26.95 33.41 12.11 12.11 12.11 12.11 14.87 27.47 10.25 10.25 10.25 10.25 13.25 13.19 16.59 16.59 16.59 16.59 24.84 31.31 10.97 10.97 10.97 10.97 13.72 26.31 7.00 7.00 7.00 7.00 6.25 18.50 17.50 17.50 17.50 17.50 25.75 32.25 1.98 1.98 1.98 1.98 3.75 3.91 .46 .46 .46 .46 .46 .47 9.20 9.20 9.20 9.20 12.15 12.10 HNF361Xa HNF362Xa HNF363Xa HNF364Xa 18.75 18.75 26.95 33.41 12.11 12.11 14.87 27.47 10.25 10.25 13.25 13.19 16.59 16.59 24.84 31.31 10.97 10.97 13.72 26.31 7.00 7.00 6.25 18.50 17.50 17.50 25.75 32.25 1.98 1.98 3.75 3.91 .46 .46 .46 .47 9.20 9.20 12.15 12.10 Dimensions (Inches) Non-Metallic VBII Interlocked Receptacle Switches Ampere Rating Dimensions (Inches) A B C D E F G 6.22 6.34 6.80 1.52 1.52 1.52 6.1 6.4 6.5 6.0 7.4 7.6 6.22 6.34 6.80 1.52 1.52 1.52 6.1 6.4 6.5 6.0 7.4 7.6 1.52 1.52 3.5 5.0 3.0 4.5 3.5 5.0 3.0 4.5 Cr-H Type Fusible (240 & 600V) 30 60 100 14.27 16.27 21.96 7.42 9.17 9.65 9.02 11.47 12.02 Cr-H Type Non-Fusible (600V max.) 30 60 100 14.27 16.27 21.96 7.42 9.17 9.65 9.02 11.47 12.02 Pyle-National Type Fusible (240 & 600V) 30 60 14.27 16.27 7.42 9.17 9.02 11.47 6.22 6.34 Pyle-National Type Non-Fusible (600V max.) 30 60 14.27 16.27 7.42 9.17 9.02a 11.47a *For inches / millimeters conversion, multiply inches by 25.4. 6.22 6.34 1.52 1.52 a imensions also apply to “L” suffix switches (less D lugs). Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 4-27 SAFETY SWITCHES Catalog Number Special Application Safety Switches Dimension Drawings 4-Pole & 6-Pole Dimensions 4 & 6-Pole Safety Switch Dimensions – Inches (mm) Mounting Enclosure Catalog Number A B C D E Figure 1, 4-Pole Fusible and Non-fusible, Type 1 HNF461 HF461 HNF462 HF462 HNF463 HF463 HNF464 HF464 24.50 (622) 29.12 (740) 24.88 (632) 33.53 (852) 27.62 (702) 36.44 (926) 36.00 (914) 49.48 (1257) 9.53 (242) 9.53 (242) 11.50 (292) 11.50 (292) 12.18 (309) 12.18 (309) 19.12 (486) 19.12 (486) 6.09 (155) 6.09 (155) 6.09 (155) 6.09 (155) 6.09 (155) 6.09 (155) 6.42 (163) 6.42 (163) F 19.00 (483) 23.50 (597) 19.00 (483) 27.50 (699) 19.36 (492) 28.11 (714) 30.88 (784) 45.50 (1130) 6.75 (171) 6.75 (171) 9.38 (238) 9.38 (238) 8.00 (203) 8.00 (203) 15.00 (381) 15.00 (381) 0.268 (7) 0.268 (7) 0.268 (7) 0.268 (7) 0.268 (7) 0.268 (7) 0.44 (11) 0.44 (11) SAFETY SWITCHES 4 Figure 2, 4 & 6-Pole Fusible Type 12/3R and 4X HF461J, HF661J, HF661S HF462J, HF662J, HF662S HF463J, HF663J, HF663S HF464J, HF664J, HF664S 29.50 (622) 9.53 (242) 6.48 (165) 31.65 (804) 5.47 (139) 0.27 (7) 33.53 (852) 11.50 (292) 6.48 (165) 35.69 (907) 8.00 (203) 0.27 (7) 36.44 (926) 12.18 (309) 6.48 (165) 38.67 (982) 8.47 (215) 0.27 (7) 49.48 (1257) 19.12 (486) 6.78 (172) 51.64 (1312) 13.44 (341) 0.33 (8) Figure 2, 4 & 6-Pole Non-fusible Type 12/3R and 4X HNF461J, HNF661J, HNF661S HNF462J, HNF662J, HNF662S HNF463J, HNF663J, HNF663S HNF464J, HNF664J, HNF664S 24.50 (622) 9.53 (242) 6.48 (165) 26.65 (667) 5.47 (139) 0.27 (7) 24.88 (632) 11.50 (292) 6.48 (165) 27.03 (687) 8.00 (203) 0.27 (7) 27.54 (700) 12.18 (309) 6.48 (165) 29.77 (756) 8.47 (215) 0.27 (7) 36.00 (914) 19.12 (486) 6.78 (172) 38.16 (969) 13.44 (341) 0.33 (8) Figure 1: Type 1 4-28 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Figure 2 : Type 12/3R and 4X
Similar documents
Die BUCHSTAVIER - Das Dosierte Leben
zusammen-, vor-, her- und hinstellten, musste dies ja so kommen. - Dies ist Werner Rabus gewidmet, der uns frei Haus diese Buchstabenkombinationen errechnete und lieferte. - Dies ist Jochen Kunzman...
More information