General and Heavy Duty Safety Switches

Transcription

General and Heavy Duty Safety Switches
• Revised •
07/15/15
General and Heavy Duty Safety Switches
Accessories
Selection
HT63
SAFETY
SWITCHES
4
HR612
Class R Fuse Clip Kits
Class T Fuse Adapter Kits
All General Duty and Heavy Duty
Switches are field convertible to accept
Class R Fuse Clip Kits. The kits prevent
the installation of Class H and K fuses
(one kit required per 3-pole switch).
All 100-600A, General Duty and 100200Amp and 1200Amp Heavy Duty
Switches are field convertible to accept
Class T fuses.800A switches are field
convertible to accept Class T fuses by
moving the load base to a pre-drilled
T fuse position.
Class R Fuse Clip Kits
Catalog
Number
Description
GSRK321
HR21
HR612
HR62
HR63
HR64
HR65A
HR66A
30A, 240V
30A, 240V
30A, 600V
60A, 600V
100A Kit
200A Kit
400A Kit
600A Kit
Kit (GD only)
Kit (HD only)
Kit/60A, 240V Kit
Kit
Class J Fusing
All 30-600A, 600V and 100-600A,240V
fusible Heavy Duty Switches are field
convertible to accept Class J fuses by
moving the load base to a pre-drilled J
fuse position. All 100-600A, 240V
fusible General Duty switches can also
be field converted to accept Class J fuses.
Class J Fuse Kits
Catalog
Number
Description
HJ66A
600A, 240V/600V Kit
Internal Shield Kits (for fusible switches)
Kits provide a clear plastic inner door to
prevent accidental contact with live parts.
Test probe holes are provided and fuses
can be replaced without removal of kit.
NEW
Class T Fuse Adapter Kitsa
Catalog
Number
Description
HT23
HT63
HT24
HT64s
HT25A
HT65A
HT26A
HT66A
TFAK82
100A, 240V Kit
100A, 600V Kit
200A, 240V Kit
200A, 600V Kit
400A, 240V Kit
400A, 600V Kit
600A, 240V Kit
600A, 600V Kit
1200A, 240V Kit
Neutral Kits
Standard Neutral Kits can be field
installed in General and Heavy Duty
Switches.
Neutral Kits
Switch Ampere Rating
Kit Catalog Number
30 GD
30 HD, 60 GD
60, 100 HD, 100 GD
200
400 & 600
800 & 1200
W410190
HN612
HN623
HN64
HN656A
HN678
HSK62SSW
HSK63SSW
200A HD
HSK64SSW
s Built to order. Allow 6–8 weeks for delivery.
a
O
ne kit per pole required.
4-18
200% Neutral Kits
UL listed 200% Neutrals are available
on 100-600A Heavy Duty Switches.
They are typically used with non-linear
transformers or where increased neutral
ampacity/lug capacity is required.
200% Neutral Kits
Switch
Ampere
Rating
Kit
Catalog
Number
100
200
HN263
HN264
400
HN656A
600
HN678A
Wire Range Line &
Load Lugs (Cu/Al)
(2)
(2)
(2)
(2)
(2)
(2)
#14-1/0 AWG
#6 AWG-300 Kcmil
1/0 AWG-600 Kcmil
#6 AWG-300 Kcmil
1/0 AWG-600 Kcmil
#6 AWG-300 Kcmil
Fuse Puller Kits
Fuse Puller Kits
Switch
Ampere Rating
Kit Catalog Number
30A HD
HSK61SSW
100A HD
HN264
Fuse Puller Kits are field installable in
30-100A Type VBII Heavy Duty Switches
(one kit required per 3-pole switch).
Internal Shield Kits b
60A HD
HN612
Switch
Ampere
Fuse Puller Kit
Rating
Catalog Number
030
HP61
HP61
b
060
HP62s
100
HP63s
N
ot designed for use in Non-metallic 4X safety
switches. Not designed for use with Auxiliary Contacts.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Product Category HDSS
• Revised •
07/15/15
General and Heavy Duty Safety Switches
Accessories
Selection
HA161234
HA261234
HLC612
Auxiliary Contacts
NEW
HG261234
Quick Connects
Auxiliary Contacts
Quick Connects
Kit Ampere
Rating
Switch
Ampere
Aux. Switch
Catalog
Number
125V
AC
Max.
250V
AC
Max.
Horsepower
Rating
28V
DC
Max.
125V
AC
Max.
250V
AC
Max.
1/2
1/2
3/4
3/4
1/2
1/2
3/4
3/4
1/2
1/2
3/4
3/4
Catalog Number
Description
HCQ62
HCQ63
HCQ64
60A 2 wire quick connect kit
100A 2 wire quick connect kit
200A 2 wire quick connect kit
With 1 NO & 1 NC Isolated Contacts
30-600
800-1200
HA161234
HA165678
10
10
10
10
7
—
With 2 NO & 2 NC Isolated Contacts
30-600
800-1200
HA261234
HA265678
10
10
10
10
7
7
Low Current PLC Type with 1 NO &
1 NC Gold Plated Contacts
30-600
800-1200
HA361234
HA365678
10
10
10
10
7
—
Copper Lug Kits
Heavy duty switches are UL approved to accept
field installed copper lug kits.
Copper Lug Kits
Switch
Ampere
Rating
30–60
100
200
400-600
800–1200
Copper Lug
Catalog
Number
Description
HLC612
HLC63s
HLC64s
HCU656An
HLC65678
(9) Lugs/Kit #14-4 AWG Cu
(9) Lugs/Kit #14-1/0 AWG Cu
(9) Lugs/Kit #6 AWG-300 Kcmil Cu
(1) Lugs/Kit #1/0 AWG-600 Kcmil Cu
(1) Lugs/Kit #1/0 AWG-600 Kcmil Cu
s Built to order. Allow 6–8 weeks for delivery.
n Purchase field replacement kit along with lugs.
Product Category HDSS
Isolated Ground Kits
Isolated Ground Kits are available on 30-600A Heavy Duty
Switches. They are normally used on circuits with a high content
of computer or other electronic loading which require a ground
which is isolated from the building ground and neutral circuits. The
kit includes both isolated and grounded terminals as listed below.
Isolated Ground Kits
Switch
Ampere
Rating
Catalog
Number
30–200
HG261234
2
2
400–600
HG2656A
4
4
Number of Terminals
Isolated
Grounded
Wire Range
Per Terminal (Cu/Al)
#14-4 AWG
2/0-14 AWG
2/0-6 AWG
Equipment Ground Kits
Equipment Ground Lug Kits are available for all General and
Heavy Duty Switches. They are field installable in Type 1
and Type 3R Switches and are factory installed as standard
in Type 4 / 4X and Type 12 and also in all VBII 4&6-pole
Switches.
Equipment Ground Kits
Switch
Ampere
Rating
Catalog
Number
Number of
Terminals
30A GD
60–200 GD
30–200 HD
400 & 600
800–1200
GSGK60
HG61234
HG61234
HG656A
HG678
2
2
2
4
8
Wire Range
Per Terminal (Cu/Al)
#14-8 AWG
#14-4 AWG
#14-4 AWG
2/0-6 AWG
#6 AWG-250 Kcmil
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
4-19
SAFETY
SWITCHES
They provide two point control power take-off capability and
are normally used on two poles on the line side when it is
required to have control power available when the switch is
in the OFF position. They provide a mounting provision for
standard ¼” quick connect terminal. Installed in the line or
load side. 30A VBII switches have lugs UL listed to accept (2)
wires per pole as standard so a 30A kit is not required.
4
Auxiliary Contacts are available only for Heavy Duty Switches.
The auxiliary contacts are available in 1 normally open and
1 normally closed or 2 normally open and 2 normally closed
configurations. Siemens offers a PLC Auxiliary Switch (30200A) that has very low resistance for low voltage and current
typical in PLC circuits. All auxiliary contacts make after and
break before main switch contacts.
• Revised •
07/15/15
General and Heavy Duty
Hub and Lug Data
Interchangeable Hubs
Conduit hubs are available for Type 3R,
12 and 4 / 4X applications. 30-200A
Type 3R Switches are provided with a
conduit hub provision and a removable
hub plate on their top rainshed.
Conduit
Size
(inches)
Catalog
Number
a
Used On
SAFETY
SWITCHES
4
Type 3R
Cover
3/4
1
1 1/4
Cover
3/4
1
1 1/4
1 1/2
2
2 1/2
2 1/2
3
3 1/2
4
ECHA000
ECHA075
ECHA100
ECHA125
ECHS000
ECHS075
ECHS100
ECHS125
ECHS150
ECHS200
ECHS250
ECHV250
ECHV300
ECHV350
ECHV400
b
30A GD Only
SSH075
SSH100
SSH125
SSH150
SSH200
SSH250
SSH300
SSH350
SSH400
Field Replacement Kits and
Neutral Barrier Kits
All Heavy Duty Switches are field
convertible for (Crimp) type lugs.
When compression lugs are required for
30-100A switches, a neutral barrier kit
is required for 1-Phase, 3W or 3-Phase,
4W applications. When compression
lugs are required on 400-1200A switches, lug mounting kits are required.
60–200A GD
30–200A HD
400–1200A
SSH150
Field Replacement Kits and
Neutral Barrier Kits
Switch
Ampere Catalog
Rating
Number
Type 4/4X
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
Selection
30
60 &
100
400
HCL612
Kit Description
Neutral Barrier Kit
HCL623
Neutral Barrier Kit
HCM65A
240V/600V Fusible Kit
240/600V NonFusible Kit
240V/600V Fusible Kit
240V/600V NonFusible Kit
1 Pole, Compression
Lug Mounting Kit
400
HNCM65A
600
HCM66A
600
HNCM66A
800 &
1200e
HCL65678n
ECHV300
Lugs
30–200A
400–600A
Note: 30 thru 200A. Type 3R Switches have
removable hub plates on rainshed. 400A and
larger Type 3R Switches have no provisions for
mounting hubs. Drill or punch hole in the field to
accommodate hub size desired.
30 & 60A Switches are suitable for use
with 60° or 75°C wire. 100–1200A are
suitable for use with 75°C rated wire.
ECHS200
Multiple Padlock Accessory
A tamper-proof device to provide for
multiple padlocking to meet OSHA or
plant requirements. Accepts up to 6
1/4” padlocks. Catalog number SL0420.
Standard Carton-12.
Wire Ranges (Line, Load and Standard Neutral)
Switch
Ampere
Rating
Wire Range with
Wire Bending Space
Per NEC Requirements
30GD
30HD
60hj
100k
200i
#14-8 AWG (Cu/AI)f
#14-6 AWG (Cu/AI)
#14-3 AWG (Cu/AI)
#14-1/0 AWG (Cu/Al)
#6 AWG-250 Kcmil (Cu/Al)
(1) 1/0 AWG-600 Kcmil (Cu/Al)
(2) 1/0 AWG-500 Kcmil (Cu/Al)
(1) 1/0 AWG-600 Kcmil (Cu/Al)
(2) 1/0 AWG-500 Kcmil (Cu/Al)
(3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load
(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral
(4) 3/0 AWG-750 Kcmil (Cu/Al) Line Load
(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral
400g
600g
800
1200
4-20
Lug Wire Range
#14-6 AWG (Cu/Al)
#14-2 AWG (Cu/Al)
#14-2 AWG (Cu/Al)
#14-1/0 AWG (Cu/Al)
#6 AWG-300 Kcmil (Cu/Al)
(2) 1/0 AWG-600 Kcmil (Cu/Al)
(2) 1/0 AWG-600 Kcmil (Cu/Al)
(3) 1/0 AWG-750 Kcmil (Cu/Al) Line Load
(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral
(4) 1/0 AWG-750 Kcmil (Cu/Al) Line Load
(4) 1/0 AWG-750 Kcmil (Cu/Al) neutral
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
SL0420
n Built to order. Allow 3-4 weeks for delivery.
Hubs suitable for 3R Switches.
Also suitable for Type 12 applications.
Neutral Barrier kits are required on 30-100A switches
only and only with 1-Phase / 3W or 3-Phase / 4W
loads. Compression Lugs mounting kits are required
on 400-1200A switches only.
d Provides mounting for a single line or load lug.
e Provides mounting for (2) compression lugs per phase
on line or load.
f Line base lugs (only) are UL approved to accept #14-6
CU/Al cable.
g Max. wire size for height reduced switches is 500 kcmil
(Cu/Al).
h All but 60A GD & Compact HD NF switches are also
UL approved for #2 Cu/Al conductors.
i All 200A Heavy Duty Switches have a wire range
& wire bending space for (1) #6-300 Kcmil (Cu/Al).
j Also for 30A oversized heavy duty switches.
k Also for 60A oversized heavy duty switches.
a
b
c
Product Category HDSS & RESI
• Revised •
07/15/15
General and Heavy Duty Safety Switches
Dimensions
Safety Switch Dimensions (Inches)* & Shipping Weights
Height
Catalog Number
*For inches / millimeters conversion, multiply inches
by 25.4.
8.13
—
15.45
—
23.15
—
31.07
—
45.81
45.81
45.81
45.81
8.19
—
15.45
—
23.15
—
31.07
—
45.81
45.81
45.81
45.81
45.81
8.19
—
12.31
—
23.15
—
31.07
—
33.96
33.96
17.33
15.45
—
17.33
19.31
17.46
—
19.31
23.16
23.15
—
—
8.16
—
15.76
—
23.46
—
31.42
—
—
—
—
—
8.16
—
15.76
—
23.46
—
31.42
—
—
—
—
—
—
8.16
—
12.62
—
23.46
—
31.42
—
—
—
—
15.77
—
—
—
17.77
—
—
—
23.46
a
Depth
With
Handle
E
Box
D
5.5
5.16
6.64
6.64
9.64
9.64
14.62
14.61
22.4
22.4
22.4
22.4
7.19
7.19
6.64
6.64
9.64
9.64
14.62
14.61
22.4
22.4
22.4
22.4
22.4
7.19
7.19
6.64
6.64
9.64
9.64
14.62
14.61
22.4
22.4
6.65
6.64
6.64
6.65
9.17
9.15
9.16
9.17
9.65
9.64
9.64
With
Handle
G
Box
F
5.94
5.94
8.7
8.7
11.7
11.67
16.68
16.68
23.404
23.404
23.404
23.404
7.69
8.16
8.7
8.7
11.7
11.67
16.68
16.68
23.404
23.404
23.404
23.404
23.404
7.69
7.69
8.71
8.71
11.7
11.67
16.68
16.68
23.404
23.404
9.02
9.01
9.01
9.02
11.47
11.53
11.53
11.47
12.02
12.01
11.97
3
3.13
5.05
5.05
5.05
5.05
6.36
6.36
6.94
6.94
6.94
6.94
3
3.13
5.05
5.05
5.05
5.05
6.36
6.36
6.94
6.94
6.94
6.94
6.94
3
3.13
5.05
5.05
5.05
5.05
6.36
6.36
6.94
6.94
5.32
5.05
5.05
5.32
5.33
5.05
5.05
5.33
5.34
5.05
5.05
5.88
5.88
8.63
8.63
8.63
8.7
10.92
10.92
9.93
9.93
9.93
9.93
5.88
5.88
8.63
8.63
8.63
8.7
10.92
10.92
9.93
9.93
9.93
9.93
9.93
5.88
5.88
8.61
8.61
8.63
8.7
10.92
10.92
9.93
9.93
10.46
10.17
10.17
10.46
10.46
10.17
10.17
10.46
10.46
10.17
10.17
Knockout
Diagram
S1
S3
S6
S8
S10
S11
S12
S13
S18
S19
S18
S19
S2
S4
S6
S8
S10
S11
S12
S13
S18
S19
S19
S18
S19
S2
S4
S7
S9
S10
S11
S12
S13
S18
S18
—
S6
S8
—
—
S16
S17
—
—
S10
S11
Shipping
Weight
(lbs.)
35 (10)
35 (10)
14
14
23
24
47
48
91.1
91.1
95.6
95.6
24 (5)
24 (5)
15
15
25
25
49
50
94.6
94.6
99.6
99.6
99.6
24 (5)
24 (5)
12
13
23
24
46
47
75
77
13
12
13
13
19
18
19
19
24
23
24
K
nocks not provided on Type 4 / 4X and 12 or in 800 &
1200A switches.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
4-21
SAFETY
SWITCHES
7.97
8.07
14.26
14.39
21.95
21.95
29.9
29.9
45.32
45.32
45.32
45.32
7.97
8.07
14.26
14.39
21.95
21.95
29.9
29.9
45.32
45.32
45.32
45.32
45.32
7.97
8.07
11.11
11.11
21.95
21.95
29.9
29.9
33.47
33.47
14.27
14.26
14.39
14.27
16.22
16.26
16.26
16.22
21.96
21.95
21.95
With
Rain Shed
C
4
GF221N
GF221NR
GF222N
GF222NR
GF223N
GF223NR
GF224N
GF224NR
GF225NA
GF225NRA
GF226NA
GF226NRA
GF321N
GF321NR
GF322N
GF322NR
GF323N
GF323NR
GF324N
GF324NR
GF325NA
GF325NRA
GF326NRA
GF326NA
GF326NRA
GNF321
GNF321R
GNF322
GNF322R
GNF323
GNF323R
GNF324
GNF324R
GNF325A
GNF326A
HF221J also HF261J
HF221N also HF261
HF221NR also HF261R
HF221S also HF261S
HF222J also HF262J
HF222N also HF262
HF222NR also HF262R
HF222S also HF262S
HF223J also HF263J
HF223N also HF263
HF223NR also HF263R
Box
A
Width
With
Door
B
• Revised •
07/15/15
General and Heavy Duty Safety Switches
Dimensions
Safety Switch Dimensions (Inches)* & Shipping Weights
SAFETY
SWITCHES
4
Height
Catalog Number
HF223S also HF263S
HF224J
HF224N
HF224NR
HF224S
HF225NRA
HF225NA
HF226NA
HF226NRA
HF227N
HF227NR
HF228N
HF228NR
HF365A
HF365JA
HF365RA
HF365SA
HF366A
HF366JA
HF366RA
HF366SA
HF321J
HF321N
HF321NR
HF321S, SS
HF322J
HF322N
HF322NR
HF322S, SS
HF323J
HF323N
HF323NR
HF323S, SS
HF324J
HF324N
HF324NR
HF324S, SS
HF325JA
HF325NA
HF325NRA
HF325SA
HF326JA
HF326NA
HF326NRA
HF326SA
HF327J
HF327N
HF327NR
HF327S
HF328N
HF328NR
HF361, PV, PVPG
HF361J, JW
HF361L
HF361N
HF361NR
HF361R, RPV, RPVPG
HF361RL, RW
HF361S, SS, SSW, SW
HF362, PV, PVPG
Box
A
21.96
29.96
29.9
29.9
29.96
45.32
45.32
45.32
45.32
66.67
66.67
66.67
66.67
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
14.27
14.26
14.39
14.27
16.27
16.26
16.26
16.27
21.96
21.95
21.95
21.96
29.96
29.9
29.9
21.96
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
66.67
66.67
66.67
66.67
66.67
66.67
14.26
14.27
16.26
14.26
14.39
14.39
16.26
14.27
16.26
Width
With
Door
B
23.16
31.07
31.07
—
31.07
45.81
45.81
45.81
45.81
67.16
—
67.16
—
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
17.33
15.45
—
17.33
19.31
17.46
—
19.31
23.16
23.15
—
23.16
31.07
31.07
—
31.07
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
67.16
67.16
—
67.16
67.16
—
15.45
17.33
17.46
15.45
—
—
—
17.33
17.46
*For inches / millimeters conversion, multiply inches
by 25.4.
4-22
With
Rain Shed
C
—
—
—
31.42
—
—
—
—
—
—
67.74
—
67.74
—
—
—
—
—
—
—
—
—
—
15.77
—
—
—
17.77
—
—
—
23.46
—
—
—
31.42
—
—
—
—
—
—
—
—
—
—
—
67.74
—
—
67.74
—
—
—
—
15.77
15.77
17.77
—
—
a
Box
D
9.65
14.62
14.62
14.61
14.62
22.4
22.4
22.4
22.4
38.4
38.4
38.4
38.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
6.65
6.64
6.64
6.65
9.17
9.15
9.16
9.17
9.65
9.64
9.64
9.65
14.62
14.62
14.61
14.62
22.4
22.4
22.4
22.4
22.4
22.4
22.4
22.4
38.4
38.4
38.4
38.4
38.4
38.4
6.64
6.65
9.15
6.64
6.64
6.64
9.16
6.65
9.15
Depth
With
Handle
E
12.02
16.95
16.98
16.99
16.95
23.404
23.404
23.404
23.404
39.96
39.96
39.96
39.96
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
9.02
9.01
9.01
9.02
11.47
11.53
11.53
11.47
12.02
12.01
11.97
12.02
16.95
16.98
16.99
16.95
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
39.96
39.96
40.25
39.96
39.96
40.25
9.01
9.02
11.53
9.01
9.01
9.01
11.53
9.02
11.53
Box
F
K
nocks not provided on Type 4 / 4X and 12 or in 800 &
1200A switches.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
5.34
6.63
6.36
6.36
6.63
6.94
6.94
6.94
6.94
9.24
9.24
9.24
9.24
6.94
6.97
6.94
7.34
6.94
6.97
6.94
7.34
5.32
5.05
5.05
5.32
5.33
5.05
5.05
5.33
5.34
5.05
5.05
5.34
6.63
6.36
6.36
6.63
6.97
6.94
6.94
7.34
6.97
6.94
6.94
7.34
9.24
9.24
9.24
9.24
9.24
9.24
5.05
5.32
5.05
5.05
5.05
5.05
5.05
5.32
5.05
With
Handle
G
10.46
12.58
12.33
12.33
12.58
9.93
9.93
9.93
9.93
14.68
14.68
14.68
14.68
9.93
10.05
9.93
10.347
9.93
10.05
9.93
10.347
10.46
10.17
10.17
10.46
10.46
10.17
10.17
10.46
10.46
10.17
10.17
10.46
12.58
12.33
12.33
12.58
10.05
9.93
9.93
10.347
10.05
9.93
9.93
10.347
14.68
14.68
14.68
14.68
14.68
14.68
10.17
10.46
10.17
10.17
10.17
10.17
10.17
10.46
10.17
Knockout
Diagram
—
—
S12
S13
—
S19
S18
S18
S19
—
—
—
—
S18
—
S19
—
S18
—
S19
—
—
S6
S8
—
—
S16
S17
—
—
S10
S11
—
—
S12
S13
—
—
S18
S19
—
—
S18
S19
—
—
—
—
—
—
—
S6
—
S16
S6
S8
S8
S17
—
S16
Shipping
Weight
(lbs.)
24
48
47
48
48
91.1
91.1
95.6
95.6
360
362
362
364
93
93
93
93
98
98
98
98
14
14
15
14
20
19
20
20
25
25
26
25
49
49
50
49
93
94.6
94.6
93
98
99.6
99.6
98
367
380
383
367
382
385
14
14
19
14
15
15
20
15
19
• Revised •
07/15/15
General and Heavy Duty Safety Switches
Dimensions
Safety Switch Dimensions (Inches)* & Shipping Weights
Height
a
Depth
With
Handle
E
11.47
11.53
11.53
11.53
11.97
11.47
12.01
12.02
12.01
11.97
11.97
12.02
16.98
16.95
16.98
16.99
16.99
16.95
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
23.404
39.96
39.96
39.96
40.25
40.25
39.96
39.96
39.96
40.25
40.25
23.404
23.404
23.404
23.404
23.404
23.404
9.01
9.02
9.01
11.53
9.02
11.53
11.47
11.53
11.97
11.47
12.01
12.02
11.97
12.02
16.98
16.95
16.99
16.95
Box
F
5.33
5.05
5.05
5.05
5.05
5.33
5.05
5.34
5.05
5.05
5.05
5.34
6.36
6.63
6.36
6.36
6.36
6.63
6.94
6.97
6.94
6.94
6.94
7.34
6.94
6.97
6.94
6.94
6.94
7.34
9.24
9.24
9.24
9.24
9.24
9.24
9.24
9.24
9.24
9.24
6.97
6.94
7.34
7.34
6.97
6.94
5.05
5.56
5.05
5.05
5.56
5.05
5.33
5.05
5.05
5.33
5.05
5.34
5.05
5.34
6.36
6.63
6.36
6.63
With
Handle
G
10.46
10.17
10.17
10.17
10.17
10.46
10.17
10.46
10.17
10.17
10.17
10.46
12.33
12.58
12.33
12.33
12.33
12.58
9.93
10.05
9.93
9.93
9.93
10.347
9.93
10.05
9.93
9.93
9.93
10.347
14.68
14.68
14.68
14.68
14.68
14.68
14.68
14.68
14.68
14.68
10.05
9.93
10.347
10.347
10.05
9.93
10.17
10.46
10.17
10.17
10.46
10.17
10.46
10.17
10.17
10.46
10.17
10.46
10.17
10.46
12.33
12.58
12.33
12.58
Shipping
Knockout Weight

Diagram (lbs.)
—
20
S16
19
S17
20
S17
20
S11
25
—
20
S10
24
—
25
S10
25
S11
26
S11
25
—
25
S12
48
—
49
S12
49
S13
48
S13
49
—
49
S18
93
—
93
S18
94.6
S19
94.6
S19
93
—
93
S18
98
—
98
S18
99.6
S19
99.6
S19
98
—
98
—
380
—
380
—
382
—
386
—
382
—
380
—
383
—
385
—
388
—
385
—
75
S19
75
—
75
—
77
—
77
S19
77
S7
12
—
13
S9
13
S17
20
—
13
S16
18
—
19
S17
19
S11
24
—
19
S10
23
—
24
S11
24
—
24
S12
46
—
47
S13
47
—
47
K
nocks not provided on Type 4 / 4X and 12 or in 800 & 1200A switches.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
4-23
SAFETY
SWITCHES
*For inches / millimeters conversion, multiply inches by 25.4.
With
Rain Shed Box
C
D
—
9.17
—
9.15
17.77
9.16
17.77
9.16
23.46
9.64
—
9.17
—
9.64
—
9.65
—
9.64
23.46
9.64
23.46
9.64
—
9.65
—
14.62
—
14.62
—
14.62
31.42
14.61
31.42
14.61
—
14.62
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
38.4
—
38.4
—
38.4
67.74
38.4
67.74
38.4
—
38.4
—
38.4
—
38.4
67.74
38.4
67.74
38.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
22.4
—
6.64
—
6.65
12.63
6.64
17.77
9.16
—
6.65
—
9.15
—
9.17
17.77
9.16
23.46
9.64
—
9.17
—
9.64
—
9.65
23.46
9.64
—
9.65
—
14.62
—
14.62
31.42
14.61
—
14.62
4
Catalog Number
HF362J, JW
HF362N
HF362NR
HF362R, RPV, RPVPG, RW
HF362RL
HF362S, SS, SSW, SW
HF363, PV, PVPG
HF363J, JW
HF363N
HF363NR
HF363R, RPV, RPVPG
HF363S, SS, SSW, SW
HF364, PV, PVPG
HF364J, JW
HF364N
HF364NR
HF364R, RPV, RPVPG
HF364S, SS, SSW, SW
HF365A
HF365JA, HF365JWA
HF365NA
HF365NRA
HF365RA
HF365SA, HF365SWA
HF366A
HF366JA, HF366JWA
HF366NA
HF366NRA
HF366RA
HF366SA
HF367
HF367J
HF367N
HF367NR
HF367R
HF367S
HF368, J, S
HF368N
HF368NR
HF368R
HNF365JA
HNF365RA
HNF365SA
HNF366SA
HNF366JA
HNF366RA
HNF361, PV, PVPG also HNF261 & HNF362H
HNF361J, JW also HNF261J & HNF362JH
HNF361R, RPV, RPVPG also HNF261R & HNF362RH
HNF361RL
HNF361S, SS, SSW, SW also HNF261S & HNF362SH
HNF362, PV, PVPG also HNF262
HNF362J, JW also HNF262J
HNF362R, RPV, RPVPG also HNF262R
HNF362RL
HNF362S, SS, SSW, SW also HNF262S
HNF363, PV, PVPG also HNF263
HNF363J, JW also HNF263J
HNF363R, RPV, RPVPG also HNF263R
HNF363S, SS, SSW, SW also HNF263S
HNF364, PV, PVPG
HNF364J, JW
HNF364R, RPV, RPVPG
HNF364S, SS, SSW, SW
Box
A
16.27
16.26
16.26
16.26
21.95
16.27
21.95
21.96
21.95
21.95
21.95
21.96
29.9
29.96
29.9
29.9
29.9
29.96
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
45.32
66.67
66.67
66.67
66.67
66.67
66.67
66.67
66.67
66.67
66.67
45.32
33.47
33.47
33.47
45.32
33.47
11.11
11.12
11.11
16.26
11.12
16.26
16.27
16.26
21.95
16.27
21.95
21.96
21.95
21.96
29.9
29.96
29.9
29.96
Width
With
Door
B
19.31
17.46
—
—
—
19.31
23.15
23.16
23.15
—
—
23.16
31.07
31.07
31.07
—
—
31.07
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
45.81
67.16
67.16
67.16
—
—
67.16
67.16
67.16
—
—
45.81
33.96
33.96
33.96
45.81
33.96
12.31
14.14
—
—
14.14
17.46
17.46
—
—
17.46
23.15
23.16
—
23.16
31.07
31.07
—
31.07
• Revised •
07/15/15
General and Heavy Duty Safety Switches
Dimensions
Safety Switch Dimensions (Inches)* & Shipping Weights
Catalog Number
HNF365JA
HNF365JWA
HNF365RA
HNF365SA, HNF365SWA
HNF366JA
HNF366RA
HNF366SA
HNF367, J
HNF367R
HNF367S
HNF368, J, S
HNF368R
LF111N
LF111NR
LF211N
LF211NR
LNF222R
Box
A
45.32
45.32
33.47
33.47
45.32
33.47
33.47
54.67
54.67
54.67
54.67
54.67
7.97
8.07
7.97
8.07
8.07
Width
With
Door
B
45.81
45.81
33.96
33.96
45.81
33.96
33.96
55.16
—
55.16
55.16
55.16
8.13
—
8.13
—
—
With
Rain Shed
C
—
—
—
—
—
—
—
—
55.7
—
—
—
—
8.16
—
8.16
8.16
Box
D
22.4
22.4
22.4
22.4
22.4
22.4
22.4
38.4
38.4
38.4
38.4
38.4
5.5
5.16
5.5
5.16
5.16
Depth
With
Handle
E
23.404
23.404
23.404
23.404
23.404
23.404
23.404
39.96
40.25
39.96
39.96
40.25
5.94
5.94
5.94
5.94
5.94
Box
F
6.97
6.97
6.94
7.34
6.97
6.94
7.34
9.24
9.24
9.24
9.24
9.24
3
3.13
3
3.13
3.13
With
Handle
G
10.05
10.05
9.93
10.347
10.05
9.93
10.347
14.68
14.68
14.68
14.68
14.68
5.38
5.38
5.38
5.38
5.38
Knockout
Diagram
—
—
S19
—
—
S19
—
—
—
—
—
—
S2
S3
S1
S3
S5
SAFETY
SWITCHES
4
Height
Type 1 or 3R
30A GD
Type 1 or 3R
60-200A GD, 30-200A HD Type VBII
Type 1 or 3R
400-1200A Type VBII (GD & HD)
Type 4/4X or 12
400-1200A HD Type VBII
*For inches / millimeters conversion, multiply inches
by 25.4.
4-24
a
K
nocks not provided on Type 4 / 4X and 12 or in 800 &
1200A switches.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Type 4/4X or 12
30-200A HD Type VBII
Shipping
Weight
(lbs.)
75
75
75
75
77
77
77
302
304
302
305
307
35 (10)
35 (10)
35 (10)
35 (10)
35 (10)
General and Heavy Duty Safety Switches
Knockout Diagrams
Type 1 & 3R Enclosures
4
SAFETY
SWITCHES
Removable plate covering
HS Type Hub opening
(Max. 2.5 Conduit)
S8
Removable plate covering
HS Type Hub opening
(Max. 2.5 Conduit)
S9
2 K.O.'s for Conduit
0.75, 1 in.
5 K.O.'s for Conduit
0.50, 0.75, 1 in.
1 0.25 dia. K.O.
2 K.O.'s for Conduit
0.75, 1 in.
5 K.O.'s for Conduit
0.50, 0.75, 1 in.
1 0.25 dia. K.O.
*For inches / millimeters conversion, multiply inches
by 25.4.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
4-25
General and Heavy Duty Safety Switches
• Revised •
07/15/15
Knockout Diagrams
SAFETY
SWITCHES
4
Type 1 & 3R Enclosures
*For inches / millimeters conversion, multiply inches
by 25.4.
4-26
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Special Application Safety Switches Dimension Drawings
Non-Metallic
Dimensions
Non-Metallic
4
H
W
D
A
B
C
E
F
G
J
HF321NX
HF322NX
HF361NXa
HF362NXa
HF363NXa
HF364NXa
18.75
18.75
18.75
18.75
26.95
33.41
12.11
12.11
12.11
12.11
14.87
27.47
10.25
10.25
10.25
10.25
13.25
13.19
16.59
16.59
16.59
16.59
24.84
31.31
10.97
10.97
10.97
10.97
13.72
26.31
7.00
7.00
7.00
7.00
6.25
18.50
17.50
17.50
17.50
17.50
25.75
32.25
1.98
1.98
1.98
1.98
3.75
3.91
.46
.46
.46
.46
.46
.47
9.20
9.20
9.20
9.20
12.15
12.10
HNF361Xa
HNF362Xa
HNF363Xa
HNF364Xa
18.75
18.75
26.95
33.41
12.11
12.11
14.87
27.47
10.25
10.25
13.25
13.19
16.59
16.59
24.84
31.31
10.97
10.97
13.72
26.31
7.00
7.00
6.25
18.50
17.50
17.50
25.75
32.25
1.98
1.98
3.75
3.91
.46
.46
.46
.47
9.20
9.20
12.15
12.10
Dimensions (Inches) Non-Metallic
VBII Interlocked Receptacle Switches
Ampere
Rating
Dimensions (Inches)
A
B
C
D
E
F
G
6.22
6.34
6.80
1.52
1.52
1.52
6.1
6.4
6.5
6.0
7.4
7.6
6.22
6.34
6.80
1.52
1.52
1.52
6.1
6.4
6.5
6.0
7.4
7.6
1.52
1.52
3.5
5.0
3.0
4.5
3.5
5.0
3.0
4.5
Cr-H Type Fusible (240 & 600V)
30
60
100
14.27
16.27
21.96
7.42
9.17
9.65
9.02
11.47
12.02
Cr-H Type Non-Fusible (600V max.)
30
60
100
14.27
16.27
21.96
7.42
9.17
9.65
9.02
11.47
12.02
Pyle-National Type Fusible (240 & 600V)
30
60
14.27
16.27
7.42
9.17
9.02
11.47
6.22
6.34
Pyle-National Type Non-Fusible (600V max.)
30
60
14.27
16.27
7.42
9.17
9.02a
11.47a
*For inches / millimeters conversion, multiply inches
by 25.4.
6.22
6.34
1.52
1.52
a
imensions also apply to “L” suffix switches (less
D
lugs).
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
4-27
SAFETY
SWITCHES
Catalog
Number
Special Application Safety Switches Dimension Drawings
4-Pole & 6-Pole
Dimensions
4 & 6-Pole Safety Switch Dimensions – Inches (mm)
Mounting Enclosure
Catalog
Number
A
B
C
D
E
Figure 1, 4-Pole Fusible and Non-fusible, Type 1
HNF461
HF461
HNF462
HF462
HNF463
HF463
HNF464
HF464
24.50 (622)
29.12 (740)
24.88 (632)
33.53 (852)
27.62 (702)
36.44 (926)
36.00 (914)
49.48 (1257)
9.53 (242)
9.53 (242)
11.50 (292)
11.50 (292)
12.18 (309)
12.18 (309)
19.12 (486)
19.12 (486)
6.09 (155)
6.09 (155)
6.09 (155)
6.09 (155)
6.09 (155)
6.09 (155)
6.42 (163)
6.42 (163)
F
19.00 (483)
23.50 (597)
19.00 (483)
27.50 (699)
19.36 (492)
28.11 (714)
30.88 (784)
45.50 (1130)
6.75 (171)
6.75 (171)
9.38 (238)
9.38 (238)
8.00 (203)
8.00 (203)
15.00 (381)
15.00 (381)
0.268 (7)
0.268 (7)
0.268 (7)
0.268 (7)
0.268 (7)
0.268 (7)
0.44 (11)
0.44 (11)
SAFETY
SWITCHES
4
Figure 2, 4 & 6-Pole Fusible Type 12/3R and 4X
HF461J, HF661J, HF661S
HF462J, HF662J, HF662S
HF463J, HF663J, HF663S
HF464J, HF664J, HF664S
29.50 (622)
9.53 (242)
6.48 (165)
31.65 (804)
5.47 (139)
0.27 (7)
33.53 (852)
11.50 (292)
6.48 (165)
35.69 (907)
8.00 (203)
0.27 (7)
36.44 (926)
12.18 (309)
6.48 (165)
38.67 (982)
8.47 (215)
0.27 (7)
49.48 (1257)
19.12 (486)
6.78 (172)
51.64 (1312)
13.44 (341)
0.33 (8)
Figure 2, 4 & 6-Pole Non-fusible Type 12/3R and 4X
HNF461J, HNF661J,
HNF661S
HNF462J, HNF662J,
HNF662S
HNF463J, HNF663J,
HNF663S
HNF464J, HNF664J,
HNF664S
24.50 (622)
9.53 (242)
6.48 (165)
26.65 (667)
5.47 (139)
0.27 (7)
24.88 (632)
11.50 (292)
6.48 (165)
27.03 (687)
8.00 (203)
0.27 (7)
27.54 (700)
12.18 (309)
6.48 (165)
29.77 (756)
8.47 (215)
0.27 (7)
36.00 (914)
19.12 (486)
6.78 (172)
38.16 (969)
13.44 (341)
0.33 (8)
Figure 1: Type 1
4-28
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Figure 2 : Type 12/3R and 4X