What is Ambient Air? 2
Transcription
What is Ambient Air? 2
What is Ambient Air? The monitoring stations does not generate any noise, and therefore, will not cause a disturbance. The equipment is calibrated in accordance with ISO 17025 on a quarterly basis, which is essential for accreditation purposes. 2 Ambient air refers to any unconfined portion of the atmosphere or outdoor air. It is a mixture of the gases: Nitrogen (78%) Oxygen (21% ) Carbon dioxide (0.03% ) a small amount of Argon and other gases. Past, present and proposed future locations for monitoring stations 6 1 Air Pollution occurs if there is a change in the composition of the ambient air caused by smoke, dust, gases, fumes, aerosols and odorous substances. 7 3 4 8 The first three monitoring stations were located in: 5 Paarl — Cape Winelands District Municipality (2008-2009) Vredenburg — West Coast District Municipality Why do we have to monitor ambient air? It is a legal requirement in terms of National Environmental Management: Air Quality Act No.39 of 2004 for the provincial authority to monitor ambient air. The Western Cape Department of Environmental Affairs and Development Planning (D:EA&DP) have developed an Air Quality Management Plan (AQMP). The information obtained from the monitoring can be used to determine the impacts of the air pollutants on the environment, as well as health impacts on the community. This information provides an indication of the quality of the air in the Western Cape and thus aided in the development phase of the AQMP as well as to monitor the effectiveness of the Implementation Plan of the AQMP. (2008-2010) 1. 2. 3. 4. Rain gauge Anemometer (measures wind speed) Stevenson screen (temperature and relative humidity) Radiometer (measures radiation) 5. 6. 7. 8. VOC passive sampler (Diagram 3) PM10 inlet Gas analyzer inlet Air-conditioned Housing unit Diagram 1: Monitoring station depicting the movable housing unit to the right and meteorological station to the left. 2 Possible sources of air pollution include transportation, power generation, industries and domestic sources, etc. Poor air quality can cause various health problems; primarily respiratory and cardiac diseases. Some air pollutants such as benzene are categorised as carcinogens (cancer-causing substances). 3 (2008-2010) These have subsequently been moved to Worcester, Malmesbury and George; respectively. The D: EA&DP is currently operating 8 monitoring stations and envisages to be operating 11 monitoring stations by the end of March 2012. The current monitoring stations are located at: 1 How does air pollution affect us? Mossel Bay — Eden District Municipality Worcester- De Jong Sub-station Malmesbury- Swartland High School Stellenbosch– Bird Street George- George Swimming Pool Oudtshoorn- Bongolethu clinic St. Helena Bay- H.P. Williams Primary School Khayelitsha- Khayelitsha Training Center Dana Bay - Mossel Bay Water Reservoir Vissershok - Small holding, Morning Star The locations were chosen because it is downwind from major air pollution sources (e.g. industries and traffic) and will be used to assess ambient air pollutant concentrations which the community is exposed to. How do we monitor air pollution? The D:EA&DP has installed Continuous Ambient Air Quality Monitoring Stations across the province. The monitoring stations consist of mobile units containing instruments to measure certain air pollutants and would be placed in selected areas throughout the Western Cape for a period of approximately one year. 3 4 1. 2. 3. 4. PM10 Analyser O3 Analyser SO2 Analyser NOx Analyser 1 2 1. 2. Shelter Radiello VOC passive sampler Diagram 2: Analysers inside housing units. Diagram 3: VOC passive sampler with shel- AREA Cape Winelands Paarl Worcester Stellenbosch Mossel Bay YEAR 2008 2009 2010 2011 2012 /09 /10 /11 /12 /13 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X George Oudtshoorn Eden X Dana Bay West Coast Vredenburg Malmesbury St. Helena Bay Overberg X X Caledon Maitland Vissershok City of Cape Town Khayelitsha Hout Bay X X Table: Past, present and proposed locations of the monitoring stations What is measured? Pollutants, commonly known as criteria pollutants, for which there are local and international standards to evaluate them against, are measured. These are: O3 (Ozone) PM10 (Particulate Matter less than 10 micron) SO2 (Sulphur Dioxide) NOx (Oxides of Nitrogen) CO (Carbon Monoxide) Other pollutants of concern that are being measured are: H2S (Hydrogen Sulphide) CO2 (Carbon Dioxide) PM2.5 (Particulate Matter less than 2.5 micron) TRS (Total Reduced Sulphur) Some monitoring stations also have Continuous Volatile Organic Compound (VOC’s) analysers, while VOC’s are measured with VOC passive samplers at the other monitoring stations. Meteorological data (wind speed, wind direction, temperature, relative humidity, radiation and rainfall) is also measured to better understand the pollution patterns in the area. What are Ambient Air Quality Standards? Air Quality Standards refer to the level of pollutants prescribed by regulations that cannot be exceeded during a given time in a defined area. It is necessary to monitor these pollutants to ensure compliance to the Air Quality Standards. What value does the data possess? The monitoring data is analysed and compiled into daily, monthly and annual reports that describe the status of the air quality within the province. The monitoring data can also be used for Atmospheric Dispersion Modeling to inform decision making. How can the community get involved? You can become involved by reporting any air pollution, or odour problems in your area and by attending public participation meetings, which are advertised in your local newspaper. For more information, contact any of the following officials: Western Cape Department of Environmental Affairs and Development Planning Dr. Joy Leaner Director: Pollution Management Telephone: 021 483 2798 Cellphone: 084 409 6909 E-mail: [email protected] Mr. Kamaseelan Chetty Deputy Director: Air Quality Management Telephone: 021 483 2749 Cellphone: 074 502 8023 This brochure was produced and printed by the Directorate: Pollution Management, SubDirectorate: Air Quality Management. Printed on organic glossy paper INFORMATION BROCHURE: MOBILE AMBIENT AIR QUALITY MONITORS IN THE WESTERN CAPE