madir-D
Transcription
madir-D
madIR-D www.madur.com IR sensor system CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS madur rich offer of gas analysers is supplemented by sensors for single gases. Sensors are available in OEM form - perfect solution as a suplement for customer’s larger installation. Measurement results are available as analogue (voltage / current) signal. Sensors are also available in standalone version, with housing, display, data-logger. Ideal when measurement of only one gas component is required, and when measurement environment does not force to use gas conditioner. The second division of sensors concerns measurement method. madur offers NDIR and electrochemical single gas sensors. madur Polska sp. z o.o. [email protected] 1 madIR-EN-v01.00 madIR-D CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS Available for gases: CO2, CH4, CO, N2O, CHF3 (R23 cooling agent), acetone 2x analogue outputs - one current (0mA ÷ 20mA or 4mA ÷ 20mA) and one voltage (0V ÷ 5V or 0V ÷ 10V) RS-232C interface for communication with PC computer Powerful PC programme for administrating sensor Housing made of ABS 4,5 digit display Data-logger with SD card for results collection Miniature diaphragm pump Miniature solenoid valve for automatic ventilation and zeroing Aluminium chassis for sensor and its equipment Modular construction - each aforesaid piece of equipment may be selected independently NDIR GAS SENSOR WITH OPTIONAL EQUIPMENT NDIR SENSOR UNIT LCD DISPLAY 4,5 DIGIT SOLENOID VALVE FOR AUTOMATIC VENTILATION madur Polska sp. z o.o. [email protected] MINIATURE GAS FILTER SOFTWARE & DOCUMENTS CD (NOT IN SCALE) 2 DATA - LOGGER MODULE WITH SD CARD MEMBRANE GAS PUMP madIR-EN-v01.00 madIR-D CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS OEM SENSOR PUMP SOCKET POWER SUPPLY & ANALOGUE OUTPUTS SOCKETS OTHER EQUIPMENT (E.G. VALVE) SOCKET GND VDD UOUT DATA-LOGGER SOCKET RS232C SOCKET GND IOUT DISPLAY SOCKET RS232C CABLE HYDROPHOBIC FILTER PROG RXD GND TXD madur Polska sp. z o.o. [email protected] 3 madIR-EN-v01.00 madIR-D CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS NDIR SENSOR IN STANDALONE VERISON INSTALLED IN ABS HOUSING (TWO SIZES OF HOUSING) LCD DISPLAY RS232C CONNECTOR POWER LED PG-7 CABLE PASS DATA-LOGGER BAY (UNOCCUPIED) GAS INLET & OUTLET RS232C CABLE madur Polska sp. z o.o. [email protected] 4 madIR-EN-v01.00 madIR-D CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS OEM SENSOR AND ITS EQUIPMENT INSTALLED ON ALUMINIUM CHASSIS (TWO SIZES OF CHASSIS) NDIR SENSOR UNIT GAS PUMP (OPTIONAL) SOLENOID VALVE (OPTIONAL) CHASSIS madur Polska sp. z o.o. [email protected] 5 madIR-EN-v01.00 madIR-D CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS GENERAL PARAMETERS - OEM VERSION 55 mm * 120 ÷ 224 mm * 70 mm Dimensions (W * H * D) Weight 60 ÷ 300 g Storing temperature 0°C ÷ 60°C Operating conditions T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing) Power supply: input | maximal power consumption 13 V ÷ 30 V DC or 12 V ÷ 24 V AC | 15 W Chassis material Aluminium, powder coated Communication interface with PC computer RS-232C Analogue outputs: current | voltage 0/4 mA ÷ 20 mA | 0 V÷ 10 V Ventilation valve (optional): type | maximal pressure 2-way | 2 bar GENERAL PARAMETERS - BOX SHORT VERSION LONG VERSION Dimensions (W * H * D) 80 mm * 120 mm * 80 mm 80 mm * 240 mm * 80 mm Weight 150 g ÷ 450 g 200 g ÷ 500 g Casing’s material ABS Display 4,5 digit Gas pump (optional) Diaphragm, ma 0,6l/min. ÷ 0,9l/min. Data-logger (optional): type | size | number of results madur Polska sp. z o.o. [email protected] SD flash card | max 4GB | practically unlimited 6 madIR-EN-v01.00 madIR-D CHARACTERISTIC FEATURES TECHNICAL DATA SENSORS CO - CARBON MONOXIDE NDIR 10% | 0,01 ppm ± 0,05% abs. or 5% rel. 45 sec NDIR 25% | 0,01 ppm ± 0,05% abs. or 5% rel. 45 sec NDIR 50% | 0,01 ppm ± 0,05% abs. or 5% rel. 45 sec NDIR 100% | 0,1 ppm ± 0,5% abs. or 5% rel. 45 sec NDIR 2,5% | 0,01% ± 0,05% abs. or 5% rel. 45 sec NDIR 5% | 0,01% ± 0,05% abs. or 5% rel. 45 sec NDIR 10% | 0,01% ± 0,05% abs. or 5% rel. 45 sec NDIR 25% | 0,01% ± 0,05% abs. or 5% rel. 45 sec NDIR 50% | 0,01% ± 0,05% abs. or 5% rel. 45 sec NDIR 100% | 0,1% ± 0,5% abs. or 5% rel. 45 sec NDIR 5% | 0,1% ± 0,05% abs. or 5% rel. 45 sec NDIR 10% | 0,1% ± 0,05% abs. or 5% rel. 45 sec NDIR 25% | 0,1% ± 0,05% abs. or 5% rel. 45 sec NDIR 100% | 0,1% ± 0,5% abs. or 5% rel. 45 sec NDIR 2 000 ppm | 1 ppm ± 10 ppm abs. or 5% rel. 45 sec NDIR 5 000 ppm | 1 ppm ± 10 ppm abs. or 5% rel. 45 sec CxHy - TOTAL HYDROCARBONS N2O - NITROUS OXIDE CHF3 - FLUOROFORM (REFRIGERANT R23) NDIR 2,5% | 0,01% ± 0,05% abs. or 5% rel. 45 sec NDIR 15% | 0,01% ± 0,05% abs. or 5% rel. 45 sec madur Polska sp. z o.o. [email protected] 7 madIR-EN-v01.00