How to choose the right LNB for the Ku-band QPSK
Transcription
How to choose the right LNB for the Ku-band QPSK
2003-05-19 How to choose the right LNB for the Ku-band QPSK First you have to look at the Data rate, Symbol rate or Bandwidth to select the recommended LO stability. Please note that all models can be used for higher rate or specified bandwidth. Data rate from 20 kbps from 200 kbps from 500 kbps from 2 Mbps from 3 Mbps from 20 Mbps from 30 Mbps from 40 Mbps from 60 Mbps Recommended Model and LO Stability PLL ext. 10 MHz ref. (LO stability depends on the external reference) PLL LO stability +/- 10 kHz PLL LO stability +/- 25 kHz PLL LO stability +/-100 kHz PLL LO stability +/-150 kHz LNB with DRO oscillator LO stability +/- 1 MHz LNB with DRO oscillator LO stability +/- 1.5 MHz LNB with DRO oscillator LO stability +/- 2 MHz LNB with DRO oscillator LO stability +/- 3 MHz Symbol rate from 10 kSamples/s from 100 kSamples/s from 250 kSamples/s from 1 MSamples/s from 1.5 MSamples/s from 10 MSamples/s from 15 MSamples/s from 20 MSamples/s from 30 MSamples/s Recommended Model and LO Stability PLL ext. 10 MHz ref. (LO stability depends on the external reference) PLL LO stability +/- 10 kHz PLL LO stability +/- 25 kHz PLL LO stability +/-100 kHz PLL LO stability +/-150 kHz LNB with DRO oscillator LO stability +/- 1 MHz LNB with DRO oscillator LO stability +/- 1.5 MHz LNB with DRO oscillator LO stability +/- 2 MHz LNB with DRO oscillator LO stability +/- 3 MHz Bandwidth from 10 kHz from 100 kHz from 250 kHz from 1 MHz from 1.5 MHz from 10 MHz from 15 MHz from 20 MHz from 30 MHz Recommended Model and LO Stability PLL ext. 10 MHz ref. (LO stability depends on the external reference) PLL LO stability +/- 10 kHz PLL LO stability +/- 25 kHz PLL LO stability +/-100 kHz PLL LO stability +/-150 kHz LNB with DRO oscillator LO stability +/- 1 MHz LNB with DRO oscillator LO stability +/- 1.5 MHz LNB with DRO oscillator LO stability +/- 2 MHz LNB with DRO oscillator LO stability +/- 3 MHz The Phase noise and Noise figure. All SMW models has low Phase noise and Noise Figure, and are not neccessary to select for the LNB. Please look in the specifications. Secondly you have to look at the Gain. The figures are general and may vary depending on how strong the signals are. Size of the dish up to 3.0 m 3.4 m 3.8 m 4.5 m 5.0 m 6.3 m 6.3 m 7.2 m 8.1 m 9.3 m 9.3 m 11 m 13 m Gain (guideline value) Standard gain Max 50 dB Max 48 dB Max 47 dB Max 47 dB Max 44 dB Max 44 dB Max 43 dB Max 42 dB Max 41 dB Max 41 dB Max 40 dB Max 38 dB If you have any questions you are very welcome to contact us at: SMW AB Box 230 591 23 MOTALA, SWEDEN Tel. +46 141 21 61 35 Fax. +46 141 21 52 24 e-mail: [email protected] Website: http://www.smw.se