B #LCK418 INSTALLATION INSTRUCTION FOR MULLION
Transcription
B #LCK418 INSTALLATION INSTRUCTION FOR MULLION
INSTALLATION INSTRUCTION FOR #LCK418 MULLION B 1. Secure bottom retainer A onto surface of finished floor using (3) three 2” roundhead screws. TOP RETAINER 2. Secure top retainer B onto surface of top stop using (4) four #14x1” flat head wood screws for wooden surface or (4) four 1/4”#20x5/8” flat head machine screws for metal surface. TOP STOP TOP RETAINER DOOR 3. Measure and cut mullion C , if necessary, to achieve exact fit. MULLION 4. Measure height of strike from finished floor. (41-1/2” standard height for 9800 & 2200 exit devices.) C ADAPTOR FOR NARROW TRANSOM BAR 5. Drill and tap for strike. TOP STOP 6. Position and secure strike. TOP RETAINER DOOR MULLION CL OF MULLION D TRIM HORIZONTAL CL OF STRIKE SCREWS 9/16” 418 MULLION BACKSET “A” MINIMUM CLEAR STILE REQUIREMENTS TRIM AND MULLION EXIT BACKSET FLW/FSW ET/STS PTB/PSB “A” DEVICE MAL/MSL 2200 5000 2-7/8" 4-1/8" 4-5/8" 4-3/16" 9800 7700 A BOTTOM RETAINER 2-1/2” VERTICAL C OF L CHASSIS NOTES: *Once the strike has been installed and adjusted, drill and tap two (2) #10-24 round head machine screws *When using door silencers on the frame decrease D by silencer height e.g. [ 9/16” less silencer height ] * For “GLASS BEAD” shims, increase D by the shim height e.g. [ 9/16” plus shim height ] 3” 1-1/2” 1-1/4” INSTRUCTIONS ON HOW TO INSTALL THE CYLINDER ON THE LOCKABLE MULLION 1. Loosen the Cylinder Lock Screw, making at least five turns. 2. Push the Cylinder Lock inwards. 3. Install the supplied Cam to the Cylinder. Assemble the MCCR3812 (Cylinder Compression Ring) with the cylinder on the Mullion. 4. Turn cylinder clockwise (13 to 14 turns) while at the same time pushing the latch down. Release latch after final turn. Make sure latch moves freely. Otherwise ± 1 full turn. Note: Make sure position of the cylinder cam points upwards towards the latch. 5. Tighten the Cylinder Lock Screw. For Interchangeable Core Housing, follow step 1 thru 5. Install Core on the cylinder housing before step 4 to prevent misallignment of the cylinder cam. To order, specify 307-604 for SFIC. 130321bt/ag