B #LCK418 INSTALLATION INSTRUCTION FOR MULLION

Transcription

B #LCK418 INSTALLATION INSTRUCTION FOR MULLION
INSTALLATION INSTRUCTION FOR #LCK418 MULLION
B
1. Secure bottom retainer A
onto surface of finished floor
using (3) three 2” roundhead
screws.
TOP RETAINER
2. Secure top retainer B onto
surface of top stop using
(4) four #14x1” flat head
wood screws for wooden
surface or (4) four 1/4”#20x5/8”
flat head machine screws for
metal surface.
TOP STOP
TOP RETAINER
DOOR
3. Measure and cut mullion C , if
necessary, to achieve exact fit.
MULLION
4. Measure height of strike from
finished floor. (41-1/2” standard
height for 9800 & 2200 exit
devices.)
C
ADAPTOR FOR
NARROW
TRANSOM BAR
5. Drill and tap for strike.
TOP STOP
6. Position and secure strike.
TOP RETAINER
DOOR
MULLION
CL OF MULLION
D
TRIM
HORIZONTAL CL
OF STRIKE SCREWS
9/16”
418 MULLION
BACKSET
“A”
MINIMUM CLEAR STILE REQUIREMENTS
TRIM AND MULLION
EXIT BACKSET
FLW/FSW
ET/STS PTB/PSB
“A”
DEVICE
MAL/MSL
2200
5000
2-7/8"
4-1/8"
4-5/8"
4-3/16"
9800
7700
A
BOTTOM RETAINER
2-1/2”
VERTICAL C OF
L
CHASSIS
NOTES:
*Once the strike has been installed and adjusted, drill
and tap two (2) #10-24 round head machine screws
*When using door silencers on the frame decrease D
by silencer height e.g. [ 9/16” less silencer height ]
* For “GLASS BEAD” shims, increase D by the shim
height e.g. [ 9/16” plus shim height ]
3”
1-1/2”
1-1/4”
INSTRUCTIONS ON HOW TO INSTALL THE CYLINDER ON THE LOCKABLE MULLION
1. Loosen the Cylinder Lock Screw,
making at least five turns.
2. Push the Cylinder Lock inwards.
3. Install the supplied Cam to the Cylinder.
Assemble the MCCR3812 (Cylinder Compression
Ring) with the cylinder on the Mullion.
4. Turn cylinder clockwise (13 to 14 turns)
while at the same time pushing the latch down.
Release latch after final turn. Make sure latch
moves freely. Otherwise ± 1 full turn.
Note: Make sure position of the cylinder
cam points upwards towards the latch.
5. Tighten the Cylinder Lock Screw.
For Interchangeable Core Housing, follow
step 1 thru 5. Install Core on the cylinder housing
before step 4 to prevent misallignment of
the cylinder cam.
To order, specify 307-604 for SFIC.
130321bt/ag