How to install INSTALLATION MANUAL Power peak-cut control board MODEL:TCB-PCDM2E
Transcription
How to install INSTALLATION MANUAL Power peak-cut control board MODEL:TCB-PCDM2E
INSTALLATION MANUAL Power peak-cut control board MODEL:TCB-PCDM2E How to install (1) Be sure to turn off the power switch before installing. (2) Place this P.C. board by using the support on the upper side of the electric component box. There are four installation holes to place the support on the upper side of the electric Safety Precautions Please read this section carefully before installation work to install the accessory parts in the prescribed manner. The precaution given here deal with serious safety issues. It is, therefore, of the utmost importance that they are observed in full. l The meanings of safety-related symbol are as follows: component box. l WARNING Correct direction Be careful the terminal block direction as the interior side. (4) Connect the P.C.board (TCB-PCDM2E)PJ17 This symbol is used to identify action which, if carried out in an incorrect ignoring this indication, could lead to serious personal injury or even death. CAUTION This symbol is used to identify action which, if carried out in an incorrect ignoring this indication, could lead to serious human injury or property damage. l Incorrect direction (3) Install the P.C.board to the supports. After installation work has been completed, perform a trial operation of the equipment in order to ensure that it is operating normally, and then hand over to the customer and ask to keep this Safety Precautions and Installation Instruction. withconnection cable. (5) Bind the remaining connection cable with the attached banding band. Wiring Length Input wiring WARNING Installation of accessory parts should be performed either by personnel from this dealer where it was purchased or by specialist installation technicians. l Incorrect installation by unqualified personnel can result in electric shock, fire or abnormal operation. Reassembling, repair, or modification of this accessory parts is strictry forbidden. l Failure to follow these directions can result in inflammation, earth leakage or abnormal operation causing electric shock or injury. Use the specified wires for wiring connect the terminals securely fix. To prevent external forces applied to the terminals from affecting the terminals. Do not install a location where flammable gasses may be present. l Fire may break out should flammable gas leak into the vicinity of the parts. Repair of the accessory parts must also carried out by personnel from dealer where it was purcased. l Fire may break out should flammable gas leak into the vicinity of the parts. Terminal block and outdoor unit interface CN513 Size Type 0.75mm2 Shield wire * * Shield wire Up to 500m 2-core or 3-core, Up to 200m 2-core, 0.75mm2 Output wiring Up to 400m 2-core, 1.5mm2 * In conformity with design 60245 IEC 57 (1) Refer to the "Electric wiring diagram" when wiring. (2) Be sure to use the shield wire to prevent noise trouble, and perform the grounding at both sides of shield wires. (3) Fix the output wiring with the wire clamp and banding band. (3)-1. Let the output wiring into the banding band and band it together with the other wiring. (3)-2. Fix the wire-clamp using the screw hole on the "B" position. [ Electric component box ] Feature The upper limit capacity of the outdoor unit is restricted based on the demand request signal from outside Dimension A B Accesory parts Terminal(Screw M3) 4-φ4 hole No. 1 2 3 4 5 6 Size(mm):H20 x L85 x W71 Weight(g): 65 2 2 Parts name Connection cable Support to fix the board Earth screw Wire-clamp Screw for wire-clamp Banding band Banding band Q’ty 1 4 2 1 1 2 Wire-clamp Output wiring (Local supply) Connector and Switch position on interface PC board Terminal(Screw M4) <Connector position> Placing position [ Outdoor unit ] CN513(Blue) Install this P.C. board to the upper side of the electric component box on outdoor unit. [ Electric component box ] Power peak-cut control board <Switch position> Outdoor unit interface PC board SW07 Function / Electric wiring diagram Two type control can be selected by setting SW07(Bit2) on the interface P.C. board of the header unit. [ Standard function ] I/F P.C. Board* TCB-PCDM2E Display Relay SW07 Bit2 OFF Connection Cable CN513 PJ17 OPERATION COM ON ON Local Supply L1 : Display lamp suring power peak-cut control. Power Supply In case of pulse signal Be sure to prepare the point of contact for each terminal. L1 The time of the pulse signal is more than 100msec. Don’t switch on both SW1 and SW2 terminal simultaneously. SW2 SW1 SW1 COM OFF OFF SW2 *Place this option P.C. Board to header unit. SW07-Bit2 OFF Input SW1 OFF ON SW2 ON OFF SW07-Bit1 Bit1 OFF 100%(Normal) 0%(Stop) Bit1 ON 100%(Normal) Up to 60% Display Relay (L1) OFF ON CAUTION) ・Be sure to prepare a non-voltage point for each terminal. ・Display Relay capacity of "OPERATION" Below AC240V 0.5A (COSφ=100%) When connecting load such as relay coil to "L1" load, insert the noise surge absorber. Below DC24V 1A (Non-inductive load) When connecting load such as relay coil to "L1" load, insert the the bypass circuit. ・Supplementary Insulation must be added to user touchable part of switches. [ Expansion function ] I/F P.C. Board * TCB-PCDM2E Display Relay SW07 Bit2 ON Power Supply L1 : Display lamp suring power L1 peak-cut control. Connection Cable CN513 OPERATION SW07-Bit2 ON Input Local Supply PJ17 COM ON ON COM OFF OFF * Place this option P.C. Board to header unit. SW1 SW2 SW1 OFF ON OFF ON SW2 OFF OFF ON ON SW07-Bit1 Bit1 OFF 100%(Normal) Up to 80% Up to 60% 0%(Stop) Bit1 ON 100%(Normal) Up to 85% Up to 75% Up to 60% Display Relay (L1) OFF ON ON ON CAUTION) ・Be sure to prepare non voltage continuous point of contact for each terminal. ・Display Relay capacity of "OPERATION" Below AC240V 0.5A (COSφ=100%) When connecting load such as relay coil to "L1" load, insert the noise surge absorber. Below DC24V 1A (Non-inductive load) When connecting load such as relay coil to "L1" load, insert the bypass circuit. ・Supplementary Insulation must be added to user touchable part of switches. SN:EH99839001