Considering as example: evaluation electronics YCO01IS-0CE + indicating and operator terminal isi30
Transcription
Considering as example: evaluation electronics YCO01IS-0CE + indicating and operator terminal isi30
Sample of filled in declaration "Compatibility of modules" Considering as example: evaluation electronics YCO01IS-0CE + indicating and operator terminal isi30 in combination with the platform IFS4-1500LL-NCE Eichbehörden der Länder, englischsprachige Fassung Company X, Sample Street Manufacturer: City X, XXX Country a) Metrological and technical Data : Weighing instrument (WI) accuracy class Serial number: maximum capacity 12345678 WAHR III class - verification scale interval Two ranges WI Type of weighing instrument: kg kg Max1 e1 600 0,2 kg kg Max2 e2 1500 0,5 kg kg kg kg SARTICS reduction ratio R 1,000 - number of load cells N 4 - initial zero setting range IZSR 300 kg TAC (Type Approval Certificate): correction for non uniform distributed load NUD 300 kg D04-09-015 dead load of load receptor DL 110 kg additive tare T+ 1200 kg limits of temperature range T min Owner of TAC: length of cable L 6 m Sartorius AG cross section of wire A 0,14 mm Electronic indicator accuracy class class III - Manufacturer: max. number verification scale intervals n ind 6000 - Sartorius AG load cell excitation voltage U exc 9 V minumum inputvoltage for the indicator U min 0 mV Type: min. input voltage per verification scale interval ∆ u min 0,675 µV YCO01IS-0CE + isi30 minimum/maximum load cell resistance R Lmin R Lmax 83 1050 Ω Ω TC (Test certificate): limits of temperature range T min T max -10 40 °C °C D09-95.30 + D09-95.09 fraction of the maximum permissible error p ind and/or TAC (Type Approval Certificate): cable connection (4- or 6 wire) T max -10 number of wires 40 °C °C 2 0,5 - 6 - 300 m/mm2 max. value of cable length per wire cross section (L /A )max Load cell(s) (LC) accuracy class class C - Manufacturer : maximum capacity E max 1100 kg Sartorius Hamburg minimum dead load E min 0 kg rated output C 1,94 mV/V max. number verification scale intervals n LC 3000 - minimum verification scale interval or the ratio Y = E max / v min v min Y 11000 kg - ratio Z = E max / (2 DR ) or Z 3000 minimum dead load output return DR kg input resistance of single load cell R LC 350 Ω limits of temperature range T min fraction of the maximum permissible error p LC 0,7 - fraction of the maximum permissible error p con 0,5 - Type: 011232 / 1100kg TC (Test certificate): TC6273 Revision 1 or TAC (Type Approval Certificate): Connecting elements T max -10 40 °C °C The above described modules have been applied in originally Version. Date and signature of an authorized representative of the WI-Manufacturer: GM-P9, Anhang 8.1.10 zu Abschnitt 9.1 Data input 2003-01-21 page 1 of 6 Eichbehörden der Länder, englischsprachige Fassung b) Verification of Compatibility - Two ranges weighing instrument (WI) (1) Accuracy class of weighing instrument (WI) compatible to class of indicator (IND) and load cell (LC) LC C & & IND III equal or better equal or better I. O. ? WI III YES (2) Temp.limits of the weighing instr.(WI) compared with the temp.limits of the load cell (LC) and the indicator (IND) T min T max LC -10 40 IND -10 40 & & ≤ ≥ WI -10 40 YES YES (3) Sum of the squares of the fractions p i of the max. permissible errors of connecting elements, indicator and load cells p con2 0,25 p ind2 0,25 + + + + p LC2 0,49 ≤1 ≤1 YES ≥ ≥ ≥ n (i) = Max (i) /e (i) 3000 3000 YES YES 2,27 E max 1100 YES (4) Number of verification scale intervals of the weighing instrument and the indicator two ranges weighing instrument n ind 6000 6000 i=1 i=2 (5) Maximum capacity of load cells must be compatible to Max of the weighing instrument Faktor Q (EN 45 501 No 4.12.1) : Q = (Max 2+DL +IZSR +NUD +T +)/Max 2 = (Q *Max 2*R )/N ≤ 852,5 ≤ (6a) Maximum number of verification scale intervals of load cell and number of scale intervals of the weighing instrument two ranges weighing instrument n LC 3000 3000 i=1 i=2 ≥ ≥ ≥ n (i) = Max (i) /e (i) 3000 3000 YES YES (6c) Minimum dead load output return of the load cell and smallest verification scale interval e1 of a multiple range weighing instrument n LC oder Z = E max / (2*DR ) 3000 ≥ ≥ 0,4*Max 2 /e 1 3000 YES ≥ ≥ E min 0 YES (6d) Minimum dead load of the load cells to the actual dead load of the load receptor DL *R /N 27,5 (7) Verification scale interval of the weighing instrument and minimum load cell scale interval must be compatible e 1*R /√N 0,1 ≥ ≥ v min= E max /Y 0,1 YES (8) Minimum input voltage for the indicator, minimum input voltage per verification scale interval and actual output of the LCs (unloaded WI) U = C *U exc*R *DL /(E max *N ) 0,437 ≥ ≥ U min 0 input voltage per verification interval ∆ u = C *U exc*R *e /(E max *N ) ≥ ≥ ∆ u min 0,675 YES ≤ ≤ R Lmax 1050 YES (L /A )max 300,00 YES minimum input voltage 0,79 YES (9) Allowed impedance range for the electronic indicator and actual load cell impedance R Lmin 83 ≤ ≤ R LC / N 87,5 (10) Cable length per wire cross section of the connection cable between the load cell(s) and indicator (L /A) 42,86 GM-P9, Anhang 8.1.10 zu Abschnitt 9.1 Evaluation Two ranges weighing instrument 2003-01-21 ≤ ≤ page 3 of 6