Thermo Scientific Dionex UltiMate 3000 XRS Open Autosampler
Transcription
Thermo Scientific Dionex UltiMate 3000 XRS Open Autosampler
C H R O M ATO G R A P H Y Thermo Scientific Dionex UltiMate 3000 products are UHPLC compatible by design, establishing the new standard in conventional LC. Integrating hardware, software, and separation chemistry, we offer UHPLC to everyone – for all needs. Outstanding Flexibility and Sample Capacity Automated and Versatile Sampling Flexible System Integration The Thermo Scientific Dionex UltiMate 3000 XRS Open Autosampler features a versatile automatic, open architecture sampling platform for easy access to samples and all components of the autosampler fluidics. The UltiMate 3000 XRS Open Autosampler is integrated into the LC system by an autosampler table which is adjustable in height. All other UltiMate 3000 modules are placed below the table, so each system configuration with a height of up to 64 cm (25.2 in.) neatly fits underneath the autosampler. The UltiMate 3000 XRS Open Autosampler is equipped with an ultra-high pressure injection valve (125 MPa/18,130 psi) for UHPLC and UHPLC-MS applications. Furthermore, it offers the possibility of adding up to two additional valves, arranged in a vertical stack, that can be used as switching valves. Both XRS open autosampler configurations provide an outstanding sample capacity for high throughput applications. The OAS-3300TXRS accommodates a maximum of six normal or deep well plates, 6 × 54 2-mL vials, or any combination of these formats. The OAS-3600TXRS can handle up to 12 normal well plates. Reliable sample thermostatting ensures the integrity of temperature-sensitive samples. The sample temperature can be set between 4 °C and 40 °C. P roduct Spe cifications Thermo Scientific Dionex UltiMate 3000 XRS Open Autosampler Ultra-Low Carryover The UltiMate 3000 XRS Open Autosampler features the Dynamic Load and Wash (DLW) station which provides an efficient way of reducing carryover even when working with complex samples. Up to two washing solvents, delivered by integrated micro pumps, effectively wash the entire sample path, including the injection port and valve and the outside and inside of the sample needle. Wash timing for each solvent and wash cycle options are software selectable. The use of the DLW feature in the XRS Open Autosampler results in extremely low carryover (typically <0.003% for chlorhexidine). Fully Controlled by Various Software Packages Ordering Information Other Software Integration Chromeleon™ software has the capability to integrate full instrument control for the complete range of UltiMate 3000 LC modules with other software. Thermo Scientific Dionex DCMSLink provides the integration with mass spectrometry software from Thermo Scientific’s Xcalibur software, as well as Analyst® and HyStar™ software. Additionally UltiMate 3000 instrument interfaces are available for Thermo Scientific Atlas software and Empower™ software. These solutions provide Chromeleon’s advanced instrument control capabilities in the user’s familiar software environment. Enjoy Industry-Leading Support Thermo Scientific Customer Support Centers are located in the United States, Europe, and Asia. These state-of-the-art laboratories are equipped with the full line of Thermo Scientific instrumentation and software capabilities. Support Centers provide accessible locations for advanced training and enhanced application development capabilities. Users can visit these laboratories or sign up to learn new skills in addressing challenging applications, receive training and support, and discover new, innovative HPLC, GC, and IC solutions. Part No. Rapid Separation Pumps 5845.0010OAS-3300TXRS Rapid Separation Thermostatted Open Autosampler with Extended Pressure Range 5845.0020 OAS-3600TXRS Rapid Separation Thermostatted Open Autosampler with Extended Pressure Range ULTIMATE 3000 XRS Open Autosampler Specifications Injection MethodsPushed-loop injections, either full-loop or partial-loop filling Injection range 0.1–20 µL LinearityCorrelation coefficient R > 0.9999 at 4–12 µL (partialloop injections), benzophenone in water/methanol (50:50) Precision≤ 0.5% RSD at 2 µL in full-loop and ≤ 0.5% RSD at 1 µL in partial-loop mode, 2 µL sample loop, caffeine in water/ acetonitrile (90:10), 0.1% TFA Carry over< 0.004% chlorohexidine (UV) in water/acetonitrile (90:10), 0.1% TFA, 2 µL full-loop injection, 2 µL sample loop, with two wash liquids Sample capacityOAS-3300TXRS: 6 × 54 2-mL vials, 6 × 96 and/or 384 normal or deep well plates OAS-3600TXRS: 12 × 96 and/or 384 normal well plates Sample thermostatting 4–40 °C GLP FeaturesIn Chromeleon: All system parameters are recorded by the Chromeleon Audit Trail CommunicationsAll functions controllable via LAN/USB, LAN/RS232, or RS232/USB (optional) Emission sound pressure level Typically < 65 dB(A) in 1-m-distance Dimensions (h x w x d)Table: 448–688 × 627 × 558 mm (17.6–27.1 × 24.7 × 21.9 in.) Autosampler (incl. safety guard and control terminal): 648 × 676 × 718 mm (25.5 × 26.6 × 28.3 in.) Power requirements 100-240 V, 50/60 Hz Weight Table: 16 kg (35 lb) Autosampler: 18 kg (40 lb) www.thermoscientific.com/uhplc-xrs ©2012 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. Analyst is a registered trademark of AB Sciex, HyStar is a trademark of Bruker, and Empower is a trademark of Waters Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Australia +61 3 9757 4486 Austria +43 1 616 51 25 Benelux +31 20 683 9768 +32 3 353 42 94 Brazil +55 11 3731 5140 China +852 2428 3282 Denmark +45 36 36 90 90 France +33 1 39 30 01 10 Germany +49 6126 991 0 India +91 22 2764 2735 Ireland +353 1 644 0064 Italy +39 02 51 62 1267 Japan +81 6 6885 1213 Korea +82 2 3420 8600 Singapore +65 6289 1190 Thermo Scientific Dionex products are designed, developed, and manufactured under an ISO 9001 Quality System. Sweden +46 8 473 3380 Switzerland +41 62 205 9966 Taiwan +886 2 8751 6655 UK +44 1276 691722 USA and Canada +847 295 7500 PS70156_E 08/12S P roduct Spe cifications Chromeleon Software No other data system comes close to providing the capabilities and the usability of Thermo Scientific Dionex Chromeleon Chromatography Data System (CDS) software – it’s Simply Intelligent™. The software is designed to take users from samples to results in the shortest possible time. Sequence set-up and processing, and result calculations can all be performed quickly, easily, and without training. It controls IC, LC and GC instruments from a wide range of manufacturers.