Petroleum Testing
Manual Flash Point Testers
Adjustable heater provides excellent accuracy
Pensky-Martens Closed-Cup Flash Testers are used to determine the flash point of fuels, lubricating oils,
liquids containing suspended solids, and liquids that tend to form a surface film during testing. They
feature a cover that slides the shutter open to apply test flame. Select from electrical or gas heated models.
Electrical models are equipped with a 750 watt nickel-chromium heater. Gas models have a built-in nickelplated brass natural gas burner and liquid propane burner mounted on a cast iron base. Testers include a
thermometer holder, brass test cup with handle, pilot flame, test flame reference bead, built-in stirrer, plated
brass thermometer ferrule, and cooling vents. Order stirrer motor separately below.
Tag Closed-Cup Flash Testers are used to determine the flash point of liquids with viscosity below 5.5 cSt
at 104°F (40°C) or below 9.5 cSt at 77°F (25°C), and flash point below 200°F (93°C) except cut-back asphalts,
liquids that form a surface film under test conditions, and materials that contain suspended solids. They
feature a bath and cover made of plated brass; heater is enclosed in a cast aluminum base assembly. Testers
include brass test cup, plated brass thermometer ferrules, and test flame reference bead.
Cleveland Open-Cup Flash Tester are ideal for measuring flash and fire points of all petroleum products,
except fuel oils and those having an open cup flash below 175°F (79°C). They feature a thermometer
support that raises for easy placement and removal of test cup. Heater is enclosed in a stainless steel
housing with cooling vents. Tester includes test flame applicator, thermometer support, brass test cup,
and heating plate.
Tag Open-Cup Flash Testers determine the flash and fire points of liquids up to 325°F (163°C) and flash
points of cutback asphalts at less than 200°F (93°C). They include sample test cup, plated brass liquid bath
with constant level overflow, pivoting ignition taper with pilot light, reference bead, and pivoting thermometer
holder with cast aluminum base.
Specifications
Catalog
number
& Ordering Information
ASTM
method
Power
(50/60 Hz)
Pensky-Martens closed-cup flash testers
KH-59871-00
115 VAC
D93
KH-59871-05
220 VAC
KH-59871-07
Gas heated
Tag closed-cup flash testers
KH-59871-10
115 VAC
D56
KH-59871-15
220 VAC
KH-59871-17
Gas heated
Cleveland open-cup flash tester
KH-59871-20
115 VAC
D 92
KH-59871-25
220 VAC
Tag open-cup flash testers
KH-59871-30
115 VAC
D 1310/
KH-59871-35
220 VAC
D
3143
KH-59871-37
Gas heated
Dimensions
(L x W x H)
Price
Accessories
Pensky-Martens
flash tester
59871-00 shown with
motor 59871-50
KH-59871-50 Stirrer motor for Pensky-Martens tester. Slow-speed
motor rotates stirrer at 115 rpm.
Features adjustable support bracket and rod. Installs in base of
flash tester. 115 VAC, 50/60 Hz operation
KH-59871-51 Stirrer motor for 230 VAC, 50 Hz operation
KH-59871-52 Draft shield
91⁄2" x 8" x 221⁄2"
5" x 5" x 16"
Call us now
to place
your order!
10" x 51⁄2" x 14"
10" x 7" x 17"
847-549-7600
Sample Thieves
Sample petroleum, petroleum products,
and liquefied petroleum gases
Bacon Bomb Sample Thieves let you obtain samples from
storage tanks and drums. Plunger assembly opens when
it strikes the bottom of a tank and closes when it is
withdrawn to form a tight seal. Conforms to ASTM D
4057, D 6074 or ASTM D 1265 specifications. Call our
Application Specialists for adjustable sample thieves
and measuring depths up to 18".
Catalog
number
KH-59872-20
KH-59872-22
KH-59872-24
KH-59872-26
KH-59872-28
KH-59872-30
KH-59872-12
KH-59872-16
KH-59872-18
KH-59872-04
KH-59872-06
KH-59872-08
KH-59872-10
KH-59872-00
KH-59872-02
1052
Capacity
oz (mL)
4 (118)
4 (118)
4 (118)
8 (237)
8 (237)
16 (473)
16 (473)
32 (946)
Material of Construction
Body
Seal
Plated brass
Viton®
Stainless steel
Viton
Plexiglass
Buna N
Plated brass
Viton
Stainless steel
Viton
Acrylic
Viton
Plated brass
Viton
Stainless steel
Viton
Acrylic
Viton
Plated brass
Viton
Plated brass
Metal seat
Stainless steel
Viton
Acrylic
Viton
Plated brass
Viton
Stainless steel
Viton
Dimensions
L x dia
911⁄16" x 17⁄8"
911⁄16" x 15⁄8"
131⁄4" x 17⁄8"
131⁄4" x 17⁄8"
105⁄32" x 25⁄16"
105⁄32" x 25⁄16"
121⁄32" x 23⁄4"
121⁄32" x 23⁄4"
155⁄32" x 33⁄8"
Flash Alert
Controller and Display
59872-28
Price
59871-54
Improve safety, accuracy, and productivity
of flash point testing
Replace the thermometer in flash point testers with this simpleto-use device. It frees the operator for other tasks during the timeconsuming initial heating period and provides a digital sample
temperature reading. This unit displays sample temperature as
it rises and activates an audible and visible alarm when it’s time
to apply the test flame. A low alarm signals the operator to apply
the test flame; the high alarm indicates that the temperature is
too high to begin testing and automatically disconnects power
to the test apparatus. Temperature is displayed in °F or °C, with
resolution of 1°F (0.5°C). When flash occurs, the temperature
display can be frozen, and the value recorded later.
Specifications & Ordering Information
Catalog number
KH-59871-54
KH-59871-56
Dimensions
6" W x 7" H x 9" D
Power
120 VAC, 50/60 Hz
230 VAC, 50/60 Hz
Price
U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com
Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300
l
Registration
Web
Table-of-Contents
Petroleum Testing
PE
Penetrometers
Conforms to ASTM specifications—ideal for testing lubrication grease,
asphalt, petroleum wax, and more!
A
Manual Penetrometer
Compact design and rugged construction for long service life and field applications—also
suitable for laboratory use. Adjustable head assembly on this manual penetrometer allows
accurate placement of the tip of a needle or cone on the surface of the sample. Sturdy cast
iron base provides excellent support. Built-in spirit level and leveling screws ensure
proper alignment during testing. Order cones, needles, and plungers separately below.
What’s included: 47.5-gram plunger, and 50­­- and 100-gram weights.
B
Microprocessor-Based Digital Penetrometer
Programmable tip placement and manual fine adjustment ensure accurate results.
Versatility and ease of use characterize this microprocessor-controlled penetrometer. Select
a standard scale or program alternative measurements with 0.01 mm resolution. Program
intervals of up to 9999.9 seconds in 0.1 second intervals or use the ASTM standard default
interval of 5.0 seconds. The interval you select repeats automatically until changed. Output
sample number, interval, and penetration depth to your computer or printer.
A
Manual
penetrometer
59860-30
RS-232 output gives you data analysis and reporting options. Automatic timing streamlines
testing. Removable base—install head assembly onto bath or bench for irregular cup sizes.
Four programmable presets automatically lower the tip to the sample. Fine adjustment
button allows slight manual adjustments as needed. Coarse and fine controls, flex-mount
magnifier, and illuminator arm permit full manual operation for precise tip placement on
irregular samples. Express button returns head to raised position. Built-in 12 V rechargeable
battery allows field use and preserves data when AC power is interrupted. Order penetrometer
cones and needles that conform to appropriate ASTM standards separately below.
What’s included: 47.5-gram plunger, 50- and 100-gram weights, conductive probe, and
power adapter with 6-ft cord with plug.
Specifications & Ordering Information
Catalog
number
Range
Resolution
Interval
Display
RS-232
Dimensions
Power
Price
A
Manual penetrometer
KH-59860-30
Operator timed
Indicator dial
No
6"W x 18"H x 6"D
—
Microprocessor-based digital penetrometer
KH-59860-70
0 to 62.0 mm
0.1 mm
0.1 to 9999.9 seconds
10-digit, two-line LED
Yes
14"W x 18"H x 121⁄2"D
115 VAC, 60 Hz
B
Accessories
Cones, needles, and plungers listed are compatible with both penetrometers above.
Call our Applications Specialists for information about additional cones and needles.
Catalog number
Cones
KH-59860-88
KH-59860-90
KH-59860-96
KH-59860-98
Needles
KH-59860-80
KH-59860-82
KH-59860-84
KH-59860-86
KH-59860-92
KH-59860-94
Description
Weight
Conformance
Magnesium with stainless steel tip
Brass with stainless steel tip
Aluminum, quarter scale
Stainless steel, half scale
102.5 g
102.5 g
2.48 g
22.5 g
ASTM D 217
ASTM D 217
ASTM D 1403
ASTM D 1403
SS with brass shank
Stainless steel with brass shank, NIST certified
Stainless steel with stainless steel shank
Stainless steel with stainless steel shank, NIST certified
Stainless steel
Stainless steel, NIST certified
2.5 g
2.5 g
2.5 g
2.5 g
2.5 g
2.5 g
ASTM D 5
ASTM D 5
ASTM D 5
ASTM D 5
ASTM D 1321
ASTM D 1321
KH-59860-53 Plunger, 6.9 g; for use with cone 59860-96
KH-59860-51 Plunger, 15 g; for use with cone 59860-98
Price
B
Microprocessor-based digital
penetrometer 59860-70 features
RS-232 output to PC or printer.
AOCS Method Cc 16-60
AACC
Method 58-14
U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com
Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300
l
1053
Registration
PE
Web
Table-of-Contents
Petroleum Testing
Manual Reid Vapor Pressure (RVP) Apparatus
Conforms to ASTM D323, D1267; DIN 51 754
l U
se
l
to determine vapor pressure of gasoline, volatile crude oil, liquefied
petroleum gases, and other volatile petroleum products
ccurate vapor pressure is essential for selecting storage vessels,
A
shipping containers, and safe handling of petroleum products
1
2
1 RVP Bath features a mercury type thermoregulator preset to 100°F. Bath is
constructed of stainless steel; the top rim is designed for flush mounting or free
standing operation. Bath capacity is 18 gallons (68 liters). The copper clad 500 W
immersion heater reaches set temperature in 190 minutes; recovery time
with maximum 5-bomb load is two minutes. Bath measures 41"H x 20" dia.
Description
Catalog number
KH-59877-00
KH-59877-05
Reid vapor pressure bath
Power (VAC, Hz)
120, 50/60
220, 50/60
3
RVP bath
RVP gauge
RVP test bomb
1
2
Price
3
2 RVP Gauges have a large, easy-to-read
41⁄2" dia dial. Each gauge is individually
calibrated against a dead weight standard;
accuracy is ±0.5% of full range. The bourdon
tube has a full diameter opening for
complete draining of the sample. Plastic
case
seals against moisture.
Catalog number
KH-59877-50
KH-59877-51
KH-59877-52
KH-59877-53
KH-59877-54
KH-59877-55
Range
0 to 5 lb
0 to 15 lb
0 to 30 lb
0 to 45 lb
0 to 100 lb
0 to 250 lb
Division
0.1 lb
0.1 lb
0.2 lb
0.2 lb
0.5 lb
1.0 lb
Price
3 RVP Test Bombs are leakproof and
positive sealing without tools. Bombs
are polished stainless steel with knurled
sections on body for easy gripping. Test
bombs measure 16"L x 21⁄8"OD. Pressure
model includes a 1⁄4" IPS brass needle valve
on the liquid chamber and a 1⁄2" IPS valve
between the liquid and air chambers. Order
bleeder valve and adapter assembly to
convert pressure model for LPG testing.
KH-59877-62 Bleeder valve and adapter
assembly for pressure test
bomb 59877-61
59877-00
Digital Salt-In-Crude Analyzer
Automated Ethanol Purity Analyzer
Conforms to ASTM D3230 specifications
Fast, low-cost, accurate analyses of ethanol,
water, and denaturant content
Improve desalting operations—quick analysis leads to prompt
corrective action
l Helps prevent equipment and pipeline corrosion
Determining salt content of
crude oil is critical to preventing
corrosion. This salt-in-crude
analyzer quickly analyzes
oil samples, allowing you
to make necessary operation
changes to prevent corrosion
of equipment and pipelines.
The analyzer covers a range
of 0 to 99 lbs per 1000 barrels
(PTB) with an accuracy of ±5%.
Operation is simple; program
up to four voltage presets
or key in voltage manually.
59876-00
Digital display indicates both
voltage and resulting current values.
Enter a blank offset value to automatically subtract current value of
blank sample. Built for long life, the durable epoxy-coated steel
housing measures 6"L x 7"W x 9"H. Order beakers for sample testing
separately below.
l
Specifications & Ordering Information
Catalog number
KH-59876-00
KH-59876-05
Description
Salt-in-crude analyzer
Power
120, 50/60
220, 50/60
KH-34502-05 Pyrex® beakers, 100 mL. Pack of 12
1054
Price
Precisely determine the purity
of denatured ethanol being
delivered to the terminal,
refinery, or in the blending
tank. Unit only requires
2 mL of sample and
provides a reading
in 15 seconds! Based
on a solid-state electronic
design, this device is user59862-65
friendly with no moving
parts. Through automatic calibration, the
instrument determines a baseline and adjusts electronics for optimal
results after each analysis without the use of reagents. Unit is portable
and runs on batteries with an optional power adapter.
What's included: one glass sample cell and a 120 or 240 VAC
power adapter.
Specification & Ordering Information
Display: 4 lines x 20 column LCD with back light
Dimensions: 8"L x 4"W x 6"H
Parameter
Range
Resolution
Water
0 to 5
0.01
Ethanol
75 to 100
0.01
Denaturant
0 to 20
0.01
*Vol %
Catalog number
KH-59862-65
KH-59862-67
Power (VAC, Hz)
120, 50/60
220, 50/60
Price
$0000.00
0000.00
KH-59862-71 Battery pack..............................................................$00.00
KH-59862-73 Replacement sample cell.........................................$00.00
U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com
Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300
l
Registration
Web
Table-of-Contents
Petroleum Testing
PE
Front View Distillation Apparatus
Observe temperatures of samples when evaporated and condensed under controlled conditions
Conforms to ASTM D86, D285, and related international specifications. Distillation system
evaporates and condenses samples under controlled conditions, for observation of the
temperatures at which various percentages are recovered, and/or the percentages recovered at
specified temperatures. Units have a 13.2 cu ft capacity, and measure 151⁄4"L x 181⁄4"W x 191⁄2"H.
Front View Distillation Apparatus (Groups 0, 1, 2, and 3) is designed for testing motor and
aviation gasolines, aviation turbine fuels, napthas, kerosenes, distillate fuels, natural gasoline,
liquid hydrocarbon mixtures, and other petroleum products. Features a 1000 W heater with
stepless variable control, and push-turn heater elevation control knob.
Front View Distillation Apparatus (Group 4) is designed for testing grade no. 2 fuel oil, grade no.
2-D diesel fuel oil, and other distillates requiring condenser bath temperatures up to 140°F (60°C).
Also suitable for gasolines, aviation turbine fuels, napthas, kerosenes, and other liquid petroleum
products. Features a 300 W copper immersion condenser heater with stepless electronic control.
What’s included: fully insulated stainless steel condenser and heater units (flask support
platform, viewing window, and rack and pinion heater elevation mechanism), and graduate
support block and flask support boards A and C.
Specifications
& Ordering Information
Catalog number
Heater unit orientation
Front view distillation apparatus, Groups 0, 1, 2, and 3
KH-59873-00
Right side
KH-59873-05
KH-59873-10
Left side
KH-59873-15
Front view distillation apparatus, Group 4
KH-59873-20
Right side
KH-59873-25
KH-59873-30
Left side
KH-59873-35
Power (VAC, Hz)
Price
115, 50/60
220, 50/60
115, 50/60
220, 50/60
59873-05
115, 50/60
220, 50/60
115, 50/60
220, 50/60
Portable Gasoline Analyzers
A complete gasoline test lab in a compact, easy-to-use instrument
Monitor product quality in the field, at process plants,
and where fuels are blended
l Optimize fuel and additive blending
l Minimize trans-mix and contamination problems
while increasing lab efficiency
These fully automated portable units require only 10 mL of sample to
quickly measure fuel properties and determine multiple analyte levels.
The rugged design eliminates prep time and operator bias—making them
ideal for lab or field use. These instruments have proven effective in
refineries as well as commercial, test, and research labs worldwide. Quick,
accurate fuel analysis with a variety of powerful features provides refiners
and marketers a cost-effective way to reliably evaluate product quality and
compliance almost anywhere.
l
Developed specifically for refineries, pilot plants, and R&D. Enhanced
software enables maximum flexibility for custom method development.
Users control operation and data processing directly from a computer.
59862-02
Specifications & Ordering Information
115 VAC
K-59862-08
x
x
x
x
x
x
x
x
x
Catalog number
Oxygenates (ASTM D 5845)
Benzene (ASTM D 6277)
Toluene and xlyenes
Total aromatics, olefins, saturates
Octane (RON, MON, R+M/2)
Distillation points (T50, T90)
Evaporation points (E200, E300)
Driveability index
VOC emissions calculator
Price
230 VAC
K-59862-12
x
x
x
x
x
x
x
x
x
Click
Here
Search online for all our new items—
product lines are continually updated!
www.coleparmer.com
U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com
Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300
l
1055