Document 6536245
Transcription
Document 6536245
Registration PE Web Table-of-Contents Petroleum Testing Manual Flash Point Testers Adjustable heater provides excellent accuracy Pensky-Martens Closed-Cup Flash Testers are used to determine the flash point of fuels, lubricating oils, liquids containing suspended solids, and liquids that tend to form a surface film during testing. They feature a cover that slides the shutter open to apply test flame. Select from electrical or gas heated models. Electrical models are equipped with a 750 watt nickel-chromium heater. Gas models have a built-in nickelplated brass natural gas burner and liquid propane burner mounted on a cast iron base. Testers include a thermometer holder, brass test cup with handle, pilot flame, test flame reference bead, built-in stirrer, plated brass thermometer ferrule, and cooling vents. Order stirrer motor separately below. Tag Closed-Cup Flash Testers are used to determine the flash point of liquids with viscosity below 5.5 cSt at 104°F (40°C) or below 9.5 cSt at 77°F (25°C), and flash point below 200°F (93°C) except cut-back asphalts, liquids that form a surface film under test conditions, and materials that contain suspended solids. They feature a bath and cover made of plated brass; heater is enclosed in a cast aluminum base assembly. Testers include brass test cup, plated brass thermometer ferrules, and test flame reference bead. Cleveland Open-Cup Flash Tester are ideal for measuring flash and fire points of all petroleum products, except fuel oils and those having an open cup flash below 175°F (79°C). They feature a thermometer support that raises for easy placement and removal of test cup. Heater is enclosed in a stainless steel housing with cooling vents. Tester includes test flame applicator, thermometer support, brass test cup, and heating plate. Tag Open-Cup Flash Testers determine the flash and fire points of liquids up to 325°F (163°C) and flash points of cutback asphalts at less than 200°F (93°C). They include sample test cup, plated brass liquid bath with constant level overflow, pivoting ignition taper with pilot light, reference bead, and pivoting thermometer holder with cast aluminum base. Specifications Catalog number & Ordering Information ASTM method Power (50/60 Hz) Pensky-Martens closed-cup flash testers KH-59871-00 115 VAC D93 KH-59871-05 220 VAC KH-59871-07 Gas heated Tag closed-cup flash testers KH-59871-10 115 VAC D56 KH-59871-15 220 VAC KH-59871-17 Gas heated Cleveland open-cup flash tester KH-59871-20 115 VAC D 92 KH-59871-25 220 VAC Tag open-cup flash testers KH-59871-30 115 VAC D 1310/ KH-59871-35 220 VAC D 3143 KH-59871-37 Gas heated Dimensions (L x W x H) Price Accessories Pensky-Martens flash tester 59871-00 shown with motor 59871-50 KH-59871-50 Stirrer motor for Pensky-Martens tester. Slow-speed motor rotates stirrer at 115 rpm. Features adjustable support bracket and rod. Installs in base of flash tester. 115 VAC, 50/60 Hz operation KH-59871-51 Stirrer motor for 230 VAC, 50 Hz operation KH-59871-52 Draft shield 91⁄2" x 8" x 221⁄2" 5" x 5" x 16" Call us now to place your order! 10" x 51⁄2" x 14" 10" x 7" x 17" 847-549-7600 Sample Thieves Sample petroleum, petroleum products, and liquefied petroleum gases Bacon Bomb Sample Thieves let you obtain samples from storage tanks and drums. Plunger assembly opens when it strikes the bottom of a tank and closes when it is withdrawn to form a tight seal. Conforms to ASTM D 4057, D 6074 or ASTM D 1265 specifications. Call our Application Specialists for adjustable sample thieves and measuring depths up to 18". Catalog number KH-59872-20 KH-59872-22 KH-59872-24 KH-59872-26 KH-59872-28 KH-59872-30 KH-59872-12 KH-59872-16 KH-59872-18 KH-59872-04 KH-59872-06 KH-59872-08 KH-59872-10 KH-59872-00 KH-59872-02 1052 Capacity oz (mL) 4 (118) 4 (118) 4 (118) 8 (237) 8 (237) 16 (473) 16 (473) 32 (946) Material of Construction Body Seal Plated brass Viton® Stainless steel Viton Plexiglass Buna N Plated brass Viton Stainless steel Viton Acrylic Viton Plated brass Viton Stainless steel Viton Acrylic Viton Plated brass Viton Plated brass Metal seat Stainless steel Viton Acrylic Viton Plated brass Viton Stainless steel Viton Dimensions L x dia 911⁄16" x 17⁄8" 911⁄16" x 15⁄8" 131⁄4" x 17⁄8" 131⁄4" x 17⁄8" 105⁄32" x 25⁄16" 105⁄32" x 25⁄16" 121⁄32" x 23⁄4" 121⁄32" x 23⁄4" 155⁄32" x 33⁄8" Flash Alert Controller and Display 59872-28 Price 59871-54 Improve safety, accuracy, and productivity of flash point testing Replace the thermometer in flash point testers with this simpleto-use device. It frees the operator for other tasks during the timeconsuming initial heating period and provides a digital sample temperature reading. This unit displays sample temperature as it rises and activates an audible and visible alarm when it’s time to apply the test flame. A low alarm signals the operator to apply the test flame; the high alarm indicates that the temperature is too high to begin testing and automatically disconnects power to the test apparatus. Temperature is displayed in °F or °C, with resolution of 1°F (0.5°C). When flash occurs, the temperature display can be frozen, and the value recorded later. Specifications & Ordering Information Catalog number KH-59871-54 KH-59871-56 Dimensions 6" W x 7" H x 9" D Power 120 VAC, 50/60 Hz 230 VAC, 50/60 Hz Price U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300 l Registration Web Table-of-Contents Petroleum Testing PE Penetrometers Conforms to ASTM specifications—ideal for testing lubrication grease, asphalt, petroleum wax, and more! A Manual Penetrometer Compact design and rugged construction for long service life and field applications—also suitable for laboratory use. Adjustable head assembly on this manual penetrometer allows accurate placement of the tip of a needle or cone on the surface of the sample. Sturdy cast iron base provides excellent support. Built-in spirit level and leveling screws ensure proper alignment during testing. Order cones, needles, and plungers separately below. What’s included: 47.5-gram plunger, and 50- and 100-gram weights. B Microprocessor-Based Digital Penetrometer Programmable tip placement and manual fine adjustment ensure accurate results. Versatility and ease of use characterize this microprocessor-controlled penetrometer. Select a standard scale or program alternative measurements with 0.01 mm resolution. Program intervals of up to 9999.9 seconds in 0.1 second intervals or use the ASTM standard default interval of 5.0 seconds. The interval you select repeats automatically until changed. Output sample number, interval, and penetration depth to your computer or printer. A Manual penetrometer 59860-30 RS-232 output gives you data analysis and reporting options. Automatic timing streamlines testing. Removable base—install head assembly onto bath or bench for irregular cup sizes. Four programmable presets automatically lower the tip to the sample. Fine adjustment button allows slight manual adjustments as needed. Coarse and fine controls, flex-mount magnifier, and illuminator arm permit full manual operation for precise tip placement on irregular samples. Express button returns head to raised position. Built-in 12 V rechargeable battery allows field use and preserves data when AC power is interrupted. Order penetrometer cones and needles that conform to appropriate ASTM standards separately below. What’s included: 47.5-gram plunger, 50- and 100-gram weights, conductive probe, and power adapter with 6-ft cord with plug. Specifications & Ordering Information Catalog number Range Resolution Interval Display RS-232 Dimensions Power Price A Manual penetrometer KH-59860-30 Operator timed Indicator dial No 6"W x 18"H x 6"D — Microprocessor-based digital penetrometer KH-59860-70 0 to 62.0 mm 0.1 mm 0.1 to 9999.9 seconds 10-digit, two-line LED Yes 14"W x 18"H x 121⁄2"D 115 VAC, 60 Hz B Accessories Cones, needles, and plungers listed are compatible with both penetrometers above. Call our Applications Specialists for information about additional cones and needles. Catalog number Cones KH-59860-88 KH-59860-90 KH-59860-96 KH-59860-98 Needles KH-59860-80 KH-59860-82 KH-59860-84 KH-59860-86 KH-59860-92 KH-59860-94 Description Weight Conformance Magnesium with stainless steel tip Brass with stainless steel tip Aluminum, quarter scale Stainless steel, half scale 102.5 g 102.5 g 2.48 g 22.5 g ASTM D 217 ASTM D 217 ASTM D 1403 ASTM D 1403 SS with brass shank Stainless steel with brass shank, NIST certified Stainless steel with stainless steel shank Stainless steel with stainless steel shank, NIST certified Stainless steel Stainless steel, NIST certified 2.5 g 2.5 g 2.5 g 2.5 g 2.5 g 2.5 g ASTM D 5 ASTM D 5 ASTM D 5 ASTM D 5 ASTM D 1321 ASTM D 1321 KH-59860-53 Plunger, 6.9 g; for use with cone 59860-96 KH-59860-51 Plunger, 15 g; for use with cone 59860-98 Price B Microprocessor-based digital penetrometer 59860-70 features RS-232 output to PC or printer. AOCS Method Cc 16-60 AACC Method 58-14 U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300 l 1053 Registration PE Web Table-of-Contents Petroleum Testing Manual Reid Vapor Pressure (RVP) Apparatus Conforms to ASTM D323, D1267; DIN 51 754 l U se l to determine vapor pressure of gasoline, volatile crude oil, liquefied petroleum gases, and other volatile petroleum products ccurate vapor pressure is essential for selecting storage vessels, A shipping containers, and safe handling of petroleum products 1 2 1 RVP Bath features a mercury type thermoregulator preset to 100°F. Bath is constructed of stainless steel; the top rim is designed for flush mounting or free standing operation. Bath capacity is 18 gallons (68 liters). The copper clad 500 W immersion heater reaches set temperature in 190 minutes; recovery time with maximum 5-bomb load is two minutes. Bath measures 41"H x 20" dia. Description Catalog number KH-59877-00 KH-59877-05 Reid vapor pressure bath Power (VAC, Hz) 120, 50/60 220, 50/60 3 RVP bath RVP gauge RVP test bomb 1 2 Price 3 2 RVP Gauges have a large, easy-to-read 41⁄2" dia dial. Each gauge is individually calibrated against a dead weight standard; accuracy is ±0.5% of full range. The bourdon tube has a full diameter opening for complete draining of the sample. Plastic case seals against moisture. Catalog number KH-59877-50 KH-59877-51 KH-59877-52 KH-59877-53 KH-59877-54 KH-59877-55 Range 0 to 5 lb 0 to 15 lb 0 to 30 lb 0 to 45 lb 0 to 100 lb 0 to 250 lb Division 0.1 lb 0.1 lb 0.2 lb 0.2 lb 0.5 lb 1.0 lb Price 3 RVP Test Bombs are leakproof and positive sealing without tools. Bombs are polished stainless steel with knurled sections on body for easy gripping. Test bombs measure 16"L x 21⁄8"OD. Pressure model includes a 1⁄4" IPS brass needle valve on the liquid chamber and a 1⁄2" IPS valve between the liquid and air chambers. Order bleeder valve and adapter assembly to convert pressure model for LPG testing. KH-59877-62 Bleeder valve and adapter assembly for pressure test bomb 59877-61 59877-00 Digital Salt-In-Crude Analyzer Automated Ethanol Purity Analyzer Conforms to ASTM D3230 specifications Fast, low-cost, accurate analyses of ethanol, water, and denaturant content Improve desalting operations—quick analysis leads to prompt corrective action l Helps prevent equipment and pipeline corrosion Determining salt content of crude oil is critical to preventing corrosion. This salt-in-crude analyzer quickly analyzes oil samples, allowing you to make necessary operation changes to prevent corrosion of equipment and pipelines. The analyzer covers a range of 0 to 99 lbs per 1000 barrels (PTB) with an accuracy of ±5%. Operation is simple; program up to four voltage presets or key in voltage manually. 59876-00 Digital display indicates both voltage and resulting current values. Enter a blank offset value to automatically subtract current value of blank sample. Built for long life, the durable epoxy-coated steel housing measures 6"L x 7"W x 9"H. Order beakers for sample testing separately below. l Specifications & Ordering Information Catalog number KH-59876-00 KH-59876-05 Description Salt-in-crude analyzer Power 120, 50/60 220, 50/60 KH-34502-05 Pyrex® beakers, 100 mL. Pack of 12 1054 Price Precisely determine the purity of denatured ethanol being delivered to the terminal, refinery, or in the blending tank. Unit only requires 2 mL of sample and provides a reading in 15 seconds! Based on a solid-state electronic design, this device is user59862-65 friendly with no moving parts. Through automatic calibration, the instrument determines a baseline and adjusts electronics for optimal results after each analysis without the use of reagents. Unit is portable and runs on batteries with an optional power adapter. What's included: one glass sample cell and a 120 or 240 VAC power adapter. Specification & Ordering Information Display: 4 lines x 20 column LCD with back light Dimensions: 8"L x 4"W x 6"H Parameter Range Resolution Water 0 to 5 0.01 Ethanol 75 to 100 0.01 Denaturant 0 to 20 0.01 *Vol % Catalog number KH-59862-65 KH-59862-67 Power (VAC, Hz) 120, 50/60 220, 50/60 Price $0000.00 0000.00 KH-59862-71 Battery pack..............................................................$00.00 KH-59862-73 Replacement sample cell.........................................$00.00 U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300 l Registration Web Table-of-Contents Petroleum Testing PE Front View Distillation Apparatus Observe temperatures of samples when evaporated and condensed under controlled conditions Conforms to ASTM D86, D285, and related international specifications. Distillation system evaporates and condenses samples under controlled conditions, for observation of the temperatures at which various percentages are recovered, and/or the percentages recovered at specified temperatures. Units have a 13.2 cu ft capacity, and measure 151⁄4"L x 181⁄4"W x 191⁄2"H. Front View Distillation Apparatus (Groups 0, 1, 2, and 3) is designed for testing motor and aviation gasolines, aviation turbine fuels, napthas, kerosenes, distillate fuels, natural gasoline, liquid hydrocarbon mixtures, and other petroleum products. Features a 1000 W heater with stepless variable control, and push-turn heater elevation control knob. Front View Distillation Apparatus (Group 4) is designed for testing grade no. 2 fuel oil, grade no. 2-D diesel fuel oil, and other distillates requiring condenser bath temperatures up to 140°F (60°C). Also suitable for gasolines, aviation turbine fuels, napthas, kerosenes, and other liquid petroleum products. Features a 300 W copper immersion condenser heater with stepless electronic control. What’s included: fully insulated stainless steel condenser and heater units (flask support platform, viewing window, and rack and pinion heater elevation mechanism), and graduate support block and flask support boards A and C. Specifications & Ordering Information Catalog number Heater unit orientation Front view distillation apparatus, Groups 0, 1, 2, and 3 KH-59873-00 Right side KH-59873-05 KH-59873-10 Left side KH-59873-15 Front view distillation apparatus, Group 4 KH-59873-20 Right side KH-59873-25 KH-59873-30 Left side KH-59873-35 Power (VAC, Hz) Price 115, 50/60 220, 50/60 115, 50/60 220, 50/60 59873-05 115, 50/60 220, 50/60 115, 50/60 220, 50/60 Portable Gasoline Analyzers A complete gasoline test lab in a compact, easy-to-use instrument Monitor product quality in the field, at process plants, and where fuels are blended l Optimize fuel and additive blending l Minimize trans-mix and contamination problems while increasing lab efficiency These fully automated portable units require only 10 mL of sample to quickly measure fuel properties and determine multiple analyte levels. The rugged design eliminates prep time and operator bias—making them ideal for lab or field use. These instruments have proven effective in refineries as well as commercial, test, and research labs worldwide. Quick, accurate fuel analysis with a variety of powerful features provides refiners and marketers a cost-effective way to reliably evaluate product quality and compliance almost anywhere. l Developed specifically for refineries, pilot plants, and R&D. Enhanced software enables maximum flexibility for custom method development. Users control operation and data processing directly from a computer. 59862-02 Specifications & Ordering Information 115 VAC K-59862-08 x x x x x x x x x Catalog number Oxygenates (ASTM D 5845) Benzene (ASTM D 6277) Toluene and xlyenes Total aromatics, olefins, saturates Octane (RON, MON, R+M/2) Distillation points (T50, T90) Evaporation points (E200, E300) Driveability index VOC emissions calculator Price 230 VAC K-59862-12 x x x x x x x x x Click Here Search online for all our new items— product lines are continually updated! www.coleparmer.com U.S. 800-323-4340 toll-free, 847-549-7600 (outside the U.S.), www.coleparmer.com Canada 800-363-5900 l India 91-22-6716-2222 l UK 0500-345-300 l 1055