FI302 OPERATION & MAINTENANCE INSTRUCTIONS MANUAL
Transcription
FI302 OPERATION & MAINTENANCE INSTRUCTIONS MANUAL
OPERATION & MAINTENANCE INSTRUCTIONS MANUAL FI302 F I 3 0 2 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp Introduction INTRODUCTION The FI302 is part of Smar´s first generation of FOUNDATION™ fieldbus field equipment. It is a converter intended to connect Foundation Fieldbus systems with actuators and positioners for 4 -20 mA control valves. The FI302 produces a 4 -20 mA output proportional to the input received by the Fieldbus network. Its digital technology enables an easy interface between the field and the control room, while offering several types of transference functions and interesting features that reduce installation, operation and maintenance costs. Foundation Fieldbus is a digital communication system that enables distributing control functions for field equipment and advantageously replaces conventional technology. Other protocols only disclose maintenance data, as they were not devised for control data. The main Fieldbus goal was to overcome this situation. Closed loop control with a 4 -20 mA performance requires high speed, which means higher power consumption – a feature that is not compatible with intrinsic safety. This fact led to the use of a moderately high communication speed and to devise a system with a minimum communication capability. Using scheduling synchronization, the system controls variable sampling, algorithm execution and communication. The network treatment is optimized and high circuit loop performance is achieved. Using Foundation Fieldbus Technology with its capability to interconnect several devices, very large projects can be constructed. The function block concept allows the user to easily construct the programming and overview complex control strategies (Smar CD600 users are familiar with this concept, since it was implemented a few years ago). Another advantage is flexibility, as the control strategy may be edited without having to rewire or change any hardware. The FI302 and the Smar FOUNDATION™ fieldbus family have function blocks that avoid the need for separate equipment and facilitate implementing the control strategy. Among these function blocks, the following may be enhanced: PID controller, Input Selector, Arithmetic, Signal Characterizer and Integrator. These built-in blocks improve control, reduce communication, dead-time and costs. Any FOUNDATION™ fieldbus equipment with Master Backup rapidity may work as a network master and be locally configured using a magnetic screwdriver in several situations. This tool eliminates the need for a configurator in many basic applications. Read carefully these instructions to get the best result from the FI302. III FI302 - Operation and Maintenance Instruction Manual NOTE This manual is compatible with version 3.XX. The 3 indicates the software version and the XX indicates the release. The 3.XX sign means that this manual is compatible with any release of software version-3 Waiver of responsibility The contents of this manual abides by the hardware and software used on the current equipment version. Eventually there may occur divergencies between this manual and the equipment. The information from this document are periodically reviewed and the necessary or identified corrections will be included in the following editions. Suggestions for their improvement are welcome. Warning For more objectivity and clarity, this manual does not contain all the detailed information on the product and, in addition, it does not cover every possible mounting, operation or maintenance cases. Before installing and utilizing the equipment, check if the model of the acquired equipment complies with the technical requirements for the application. This checking is the user’s responsibility. If the user needs more information, or on the event of specific problems not specified or treated in this manual, the information should be sought from Smar. Furthermore, the user recognizes that the contents of this manual by no means modify past or present agreements, confirmation or judicial relationship, in whole or in part. All of Smar’s obligation result from the purchasing agreement signed between the parties, which includes the complete and sole valid warranty term. Contractual clauses related to the warranty are not limited nor extended by virtue of the technical information contained in this manual. Only qualified personnel are allowed to participate in the activities of mounting, electrical connection, startup and maintenance of the equipment. Qualified personnel are understood to be the persons familiar with the mounting, electrical connection, startup and operation of the equipment or other similar apparatus that are technically fit for their work. Smar provides specific training to instruct and qualify such professionals. However, each country must comply with the local safety procedures, legal provisions and regulations for the mounting and operation of electrical installations, as well as with the laws and regulations on classified areas, such as intrinsic safety, explosion proof, increased safety and instrumented safety systems, among others. The user is responsible for the incorrect or inadequate handling of equipments run with pneumatic or hydraulic pressure or, still, subject to corrosive, aggressive or combustible products, since their utilization may cause severe bodily harm and/or material damages. The field equipment referred to in this manual, when acquired for classified or hazardous areas, has its certification void when having its parts replaced or interchanged without functional and approval tests by Smar or any of Smar authorized dealers, which are the competent companies for certifying that the equipment in its entirety meets the applicable standards and regulations. The same is true when converting the equipment of a communication protocol to another. In this case, it is necessary sending the equipment to Smar or any of its authorized dealer. Moreover, the certificates are different and the user is responsible for their correct use. Always respect the instructions provided in the Manual. Smar is not responsible for any losses and/or damages resulting from the inadequate use of its equipments. It is the user’s responsibility to know and apply the safety practices in his country. IV Table of Contents TABLE OF CONTENTS SECTION 1 - INSTALLATION ..........................................................................................................................................................1.1 GENERAL...................................................................................................................................................................................... 1.1 MOUNTING ................................................................................................................................................................................... 1.1 ELECTRIC CONNECTION ............................................................................................................................................................ 1.2 OUTPUT CONNECTION ........................................................................................................................................................... 1.2 CONNECTING THE FI302 TO THE FOUNDATION™ FIELDBUS ................................................................................................ 1.3 PREPARING THE FI302 BEFORE CONNECTING IT TO NETWORK ......................................................................................... 1.3 POWER CONSUMPTION ............................................................................................................................................................. 1.5 TERMINATOR ............................................................................................................................................................................... 1.5 CABLING ....................................................................................................................................................................................... 1.5 TOTAL CABLE LENGTH ............................................................................................................................................................... 1.6 CABLE SHIELDING ....................................................................................................................................................................... 1.7 GROUNDING ............................................................................................................................................................................ 1.7 COMMISSIONING ......................................................................................................................................................................... 1.7 COMMISSIONING STAGES ..................................................................................................................................................... 1.7 USE OF NON-PRECONFIGURED TO DEVICES ..................................................................................................................... 1.7 USE OF PRECONFIGURED EQUIPMENTS ............................................................................................................................ 1.8 LINKING DEVICE ...................................................................................................................................................................... 1.8 ERROR MONITORING AND DETECTION WITH LIVE LIST .................................................................................................... 1.8 INSTALLATION IN HAZARDOUS AREAS .................................................................................................................................... 1.8 EXPLOSION/FLAME PROOF ....................................................................................................................................................... 1.9 INTRINSICALLY SAFE .................................................................................................................................................................. 1.9 SECTION 2 - FUNCTIONAL DESCRIPTION ....................................................................................................................................2.1 FUNCTIONAL DESCRIPTION ...................................................................................................................................................... 2.1 SECTION 3 - OPERATION ...............................................................................................................................................................3.1 LIQUID CRYSTAL DISPLAY ........................................................................................................................................................ 3.1 MONITORING ............................................................................................................................................................................... 3.1 SECTION 4 - CONFIGURATION ......................................................................................................................................................4.1 TRANSDUCER BLOCK ................................................................................................................................................................. 4.1 HOW TO CONFIGURE A TRANSDUCER BLOCK ..................................................................................................................4.1 DISPLAY BLOCK .......................................................................................................................................................................... 4.2 HOW TO CONFIGURE A DISPLAY BLOCK ...........................................................................................................................4.2 SECTION 5 - CALIBRATION ............................................................................................................................................................5.1 SECTION 6 - MAINTENANCE ..........................................................................................................................................................6.1 DIAGNOSTIC BLOCK – DIAG ...................................................................................................................................................... 6.1 TROUBLESHOOTING .................................................................................................................................................................. 6.1 PHYSICAL INSPECTION......................................................................................................................................................... 6.1 PARAMETERS USED FOR TROUBLESHOOTING ................................................................................................................ 6.1 DISASSEMBLE PROCEDURE ..................................................................................................................................................... 6.3 EXPLODED VIEW ........................................................................................................................................................................ 6.3 ELECTRONIC CIRCUIT ............................................................................................................................................................... 6.4 ASSEMBLY PROCEDURE ........................................................................................................................................................... 6.4 INTERCHANGEABILITY............................................................................................................................................................... 6.4 SPARES ....................................................................................................................................................................................... 6.5 SPARE PART LIST ....................................................................................................................................................................... 6.5 SECTION 7 - ADVANCED CONFIGURATION .................................................................................................................................7.1 CHARACTERIZATION CURVE ..................................................................................................................................................... 7.1 DEFINITION OF PARAMETERS AND VALUES ........................................................................................................................... 7.3 SECTION 8 - LOCAL ADJUSTMENT ...............................................................................................................................................8.1 JUMPER CONFIGURATION ......................................................................................................................................................... 8.1 JUMPER J1 CONNECTION .......................................................................................................................................................... 8.1 JUMPER W1 CONNECTION......................................................................................................................................................... 8.2 SECTION 9 - TECHNICAL CHARACTERISTICS .............................................................................................................................9.1 ORDERING CODE ........................................................................................................................................................................ 9.2 V FI302 - Operation and Maintenance Instruction Manual APPENDIX A - CERTIFICATIONS INFORMATION ........................................................................................................................ A.1 MANUFACTURING LOCATION APPROVED ............................................................................................................................... A.1 EUROPEAN DIRECTIVE INFORMATION..................................................................................................................................... A.1 HAZARDOUS LOCATIONS GENERAL INFORMATION.............................................................................................................. .A.1 HAZARDOUS LOCATIONS APPROVALS ................................................................................................................................... .A.2 IDENTIFICATION PLATE AND CONTROL DRAWING ................................................................................................................. A.5 APPENDIX B – SRF – SERVICE REQUEST FORM ....................................................................................................................... B.1 RETURNING MATERIALS ............................................................................................................................................................ B.2 VI FOUNDATION Fieldbus Blocks Fieldbus to Current Converter Transducer Block – Parameter Description Description of Parameter Description Valid Range Default/ Init Value Unit Description Positive 0 None Indicates the level of static data. TAG_DESC Null Na Description of Transducer Block. 3 STRATEGY 0 None 4 ALERT_KEY 0 v 5 MODE_BLK 3 AUTO None 6 BLOCK_ERR 5 7 UPDATE_EVT Na 8 BLOCK_ALM Na 9 TRANSDUCER_DIRECTORY 0 None It is used to select several Transducer Blocks. 10 TRANSDUCER_TYPE 65535 None Indicates the type of Transducer according to its class. 11 XD_ERROR 16 None It is used to indicate calibration status. 12 COLLECTION_DIRECTORY None Specifies the number of transducer index into Transducer Block. 13 FINAL_VALUE 0 FVR It is the current value and status that comes from AO block. 14 FINAL_VALUE_RANGE 4.0 to 20.0 mA FVR The High and Low range limit values, the engineering unit code and the number of digits to the right of the decimal point to be used for Final Value. 15 CAL_POINT_HI 4 12.5 to 20.5 mA 20.0 mA The highest calibrated value. 16 CAL_POINT_LO 4 3.99 to 11.5 mA 4.0 mA The lowest calibrated value. Index Parameter 1 ST_REV 2 Manual Section 1 to 255 E 5 5 This parameter is not checked and processed by Transducer Block. Number of identification in the plant. Indicates the operation mode of Transducer Block. Indicates the status associated with hardware or software in the Transducer. It is the alert for any static data. It is used for configuration, hardware and other failures. 17 CAL_MIN_SPAN 1.0 mA The minimum calibration span value allowed. This minimum span information is necessary to ensure that when calibration is done, the two calibrated points (high and low) are not too close together. 18 CAL_UNIT mA mA The Device Description engineering units code index for the calibration values. 19 ACT_SN 0 None 20 CAL_METHOD Factory None 21 CAL_LOC NULL None 22 CAL_DATE 23 SENSOR_CAL_WHO 24 RETURN 5 25 TERMINAL_NUMBER 3 26 BACKUP_RESTORE 27 CHARACTERIZATION_TYPE 0 to 2 32 None Indicates the actuator serial number. The method of last sensor calibration. ISO defines several standard methods of calibration. This parameter is intended to record that method, or if some other method was used. The location of last sensor calibration. This describes the physical location at which the lib ti f d The date of the last sensor calibration. The name of person who is in charge of last calibration. NULL None 0 mA 0 None Indicates the input terminal number (1, 2 and 3). 5 0 None This parameter is used to do backup or to restore configuration data. 6 255 None Indicates the type of characterization curve. 1, 2, 3 This is the current value that goes to the AO Block. VII FI302 - Operation and Maintenance Instruction Manual Index 28 Parameter Manual Section Valid Range Default/ Init Value Unit 6 True/False False None Enable and disable the characterization curve. 2a8 Indicates the length of characterization curve. CURVE _BYPASS Description 29 CURVE_LENGTH 6 8 None 30 CURVE_X 6 % % Input points of characterization curve. 31 CURVE_Y 6 % % Output points of characterization curve. 32 FEEDBACK_CAL 4 0 mA 33 CAL_CONTROL 4 Disable None 34 CAL_POINT_HI_BACKUP 20.0 mA Indicates the backup for high calibration point. En/Dis The measured current value used by the calibration method. Enable and disable for calibration process. 35 CAL_POINT_LO_ BACKUP 4.0 mA Indicates the last high calibration point. 35 CAL_POINT_HI_FACTORY 20.0 mA Indicates the last low calibration point. 37 CAL_POINT_LO_FACTORY 4.0 mA Indicates the low factory calibration point. 38 ORDERING_CODE None Indicates information about factory production. CAPTION AUTO - Automatic FACTORY - Standard of factory NULL - No standard value NONE - No unit or no value Na - Non-dimentional parameter E - Parameter list FVR - Final_Value_Range, True/False - Accepts true/false values En/Dis - Enables/Disables parameter Display Block Parameters Index Parameter Manual Section Range/Options This is a tag of the block to which the parameter belongs to use up to a maximum of 32 characters. 7 BLOCK_TAG_PARAM 3 8 INDEX_RELATIVE 3 0 a 65535 This is the index related to the parameter to be actuated or viewed (1, 2...). 9 SUB_INDEX 6 1 a 255 To visualize a certain tag, opt for the index relative equal to zero, and for the sub-index equal to one. 10 MNEMONIC 11 INC_DEC 12 DECIMAL_POINT_NUMBER This is the mnemonic for the parameter identification (maximum of 16 characters). Choose the mnemonic, preferably with no more than 5 characters because, this way, it will not necessary to rotate it on display. 6 6 13 ACCESS 14 ALPHA_NUM 63 DISPLAY_REFRESH 6 6 It is the increment and decrement in decimal units when the parameter is Float or Float Status time, or integer, when the parameter is in whole units. 0a4 Monit/ Action Mnem/ Value 3 True/ False CAPTION VIII Description Monit – Monitoring Mnem – Mnemonic This is the number of digits after the decimal point (0 to 3 decimal digits) The access allows the user to read, in the case of the “Monitoring” option, and to write when “action” option is selected, and then the display will show the increment and decrement arrows. These parameters include two options: value and mnemonic. In option value it is possible to display data both in the alphanumeric and in the numeric fields, this way, in the case of a data higher than 10000, it will be shown in the alphanumeric field. It allows updating the local adjustment tree. FOUNDATION Fieldbus Blocks Diagnostic Block Parameters Manual Section Valid Range Default/ Init Value 0 Spaces 0 0 O/S Index Parameter 1 2 3 4 5 6 ST_REV TAG_DESC STRATEGY ALERT_KEY MODE_BLK BLOCK_ERR 5 7 EXE_TIME_TAG 5 Spaces Na Block tag of the selected block to measure the execution time. 8 MIN_EXE_TIME 5 +INF ms Minimum execution time of the selected block. 9 10 11 12 13 14 CUR_EXE_TIME MAX_EXE_TIME HW_REV FIRMWARE_REV DEV_SN MAIN_BOARD_SN 5 0 0 ms ms 15 BEHAVIOR 5 0 E 16 PUB_SUB_STATUS Current execution time of the selected block. Maximum execution time of the selected block. Hardware revision. Firmware revision. Device serial number. Main board serial number. Select the initial values for parameters, there are two options Adapted and Spec. Indicate if all external links is good or if at least one is bad. 17 LINK_SELECTION 18 LINK_NUMBER Number of the external link selected. 19 LINK_STATUS Status of the external link selected (see table below) 20 LINK_RECOVER 21 BLOCK_ALM 22 SAVING_CONFIG 1 a 255 Unit Null Na Null Null Na E 5 5 5 0 - Adapted 1 - Spec 0 - bom 1 - ruim 0 - First 1 - Next 2 - Previous 0 - No Action 1 - Action E 0 No Action E E Na 0 - No save 1 - save 0 E Description See Mode Parameter. Select an external link. Command a recovery process to the external link selected. The block alarm is used for all configuration, hardware, and connection failure or system problems in the block. The cause of the alert is entered in the subcode field. The first alert to become active will set the Active status in the Status attribute. As soon as the Unreported status is cleared by the alert reporting task, another block alert may be reported without clearing the Active status, if the subcode has changed. It indicates if the device is saving the configuration in a non-volatile memory. CAPTION NULL - Has no standard value Na - Non-dimensional parameter E - Parameter list. ms - Milisecond IX FI302 - Operation and Maintenance Instruction Manual X Installation Flowchart Installation Flowsheet Start Was the converter configured on the bench to match the application? Yes Install the converter on the field following the instructions below. Install the converter preferably on wether-protected areas. No Configure the engineering unit. Check the area classification and its practices. Configure the terminal(s) and output scale(s) . (Section 5 - Calibration) Install the converter (mechanically and electrically) according to the application after checking the best position for the LCD (Section 6 - Maintenance). Configure the LCD reading. (Section 4 - Configuration) Simulate the values in the Fieldbus input according to output scale and verify the signals of the 4 a 20 mA output current. Yes Is the indication correct? Power-up the converter properly. FI302 needs a external power supply for supply the 4 - 20 mA equipment . No See section 6 - Maintenance OK XI FI302 - Operation and Maintenance Instruction Manual XII Section 1 INSTALLATION General NOTE The installation carried out in hazardous areas should follow the recommendations of the IEC60079-14 standard. The FI302 is a high end device and thus, in order to take advantage to its maximum, the FI302 requires an appropriate installation. Many factors may affect the converter accuracy, among which environment conditions are the most difficult to control. In order to reduce the effects from temperature, humidity and vibration, avoid its installation in aggressive areas. The effects from temperature variation may be minimized by assembling the converter in areas protected from weather changes. If necessary, use thermal insulation against external heat sources. Humidity is harmful to the electric circuits. In areas with high relative humidity levels, the correct placing of the housing cover o-ring must be assured and hand-tight shut to press the o-ring. The housing cover should not be removed on the field so that its threads are not damaged, as they are not protected by painting. A flexible sealing material should be applied on the electric connections to avoid humidity. See details on how to connect the FI302 to Fieldbus. Mounting The display may be rotated at 90º to 90º angles for easier visualization. See figure 6.2 on section 6 – Maintenance. To access the display, unlock the locking screw on the display cover by rotating it clockwise. See figure 1.1 to locate the locking screw. COVER LOCKING SCREW HOUSING ROTATION SET SCREW Figure 1.1 - Display lid locking screw The mounting bracket makes it easier to adjust the converter in several positions, as shown on Figure 1.2 – Mounting Positions and Dimensional Drawing 1.1 FI302 - Operation and Maintenance Instruction Manual ALLOW 150 MM MINIMUM FOR LOCAL ZERO AND SPAN ADJUSTMENT WITH MAGNETIC TOOL. PLUG CONDUIT CONNECTION COMMUNICATIONS TERMINAL PLUG WALL OR PANEL MOUNTING MOUNTING BRACKET PIPE 2" FOR WALL MOUNTING 2 EXPANSION ANCHOR - S8 2 HEXAGON SCREW - 3/16”X70 FOR PANEL MOUNTING 2 BOLT AND NUTS - 1/4”X30 NOT INCLUDED Figure 1.2 - Mounting Positions and Dimensional Drawing. Electric Connection Output Connection To access the terminal block, loosen the cover locking screw to release it. Rotate the cover anticlockwise and remove it (See Figure 1.3). COVER LOCKING SCREW Figure 1.3 – Terminal Block Cover Locking Screw The housing has two threaded openings where to insert the signal cables of the connection terminal block. The threads allow connecting the wiring conduit or the cable gland. For more convenience, there are three ground terminals: one internal and two externals close to the terminal block. Figure 1.4 shows the three terminals of the converter current output channels, which are marked with numbers 1, 2 and 3. Terminal 4 is the power supply common ground to the loop controlled by the channels. The converter H1 (IEC-61158-2) power supply must be connected to the terminals marked by (+) and (-). The current output is limited by the power supply voltage on the current loop and by the conditions of the classified area. Refer to the load curve to determine the maximum equipment quantity allowed for the bus. If power fails, the outputs status will be uncertain and in case of communication loss, communication 1.2 Installation lacks, the outputs will move to fixed pre-configured values or to safety default values. BUS AND POWER SUPPLY TERMINALS GROUND CONNECTION FOR SURGE PROTECTION GROUND TERMINAL (OPTIONAL SCREW) - + 1 2 3 GROUND TERMINAL 4 COMM. + COMMUNICATION TERMINALS - LOCK Figure 1.4 – Terminal Block Connecting the FI302 to the FOUNDATION™ fieldbus The FI302 may be connected to or removed from a fieldbus network in operation. Take due precaution with this operation and prevent signal cables from touching the shielding, the ground cables or one another. Insert the FI302 on the network with communication speed equal to its own (31,25 kbps), FOUNDATION™ fieldbus protocol. Preparing the FI302 before connecting it to network The FI302 may be configured on-line or off-line by a fieldbus configuration like the Smar SYSCON installed on a Engineering station, for instance. Then, use the configuration device to attribute a tag to the converter, using the “Assign Tag” option on the menu. Download the configuration for the equipment or for the entire network. NOTE The Assign Tag may be applied on-line or off-line for specific equipment connected to a fieldbus network with other equipments. ATTENTION To attribute a new Tag to the equipment, the system configuration must be changed. This may bring some inconveniences on the control configuration. For example, the addressees configured on the previous functional blocks and links are deactivated. Therefore, if the tags are modified, the entire configuration must be revised and when applicable, the TAG list from OPC Servers shall be updated. The FI302 is protected against reverse polarity and may support ±35 VDC without causing any damage, but it will not work under these conditions. Although the FI302 cannot be affected by polarity, try and keep the polarity in all connections. In hazardous areas, the number of equipments is limited by the intrinsic safety restrictions. Consult the documents related to the use of equipment for this area. 1.3 FI302 - Operation and Maintenance Instruction Manual DCS/PLC Interface (LC700) DC Power Supply (see cargo line) Terminator Terminator DC barrier COMM C1 C2 Output 2 Equipment with 4 – 20 mA Input DC Power Supply (see cargo line) DC barrier For C1 and C2 C1 C2 The components inside the gray area are normally located in the control room Output 1 Equipment with 4 – 20 mA Input + 1 2 3 4 COMM. - + HART I.S. Communicator FI302 Junction Box Figure 1.5 – FI302 Output connections for Classified Areas. The FI302 connection for non-classified areas must follow the diagram on figure 1.6. The three available output channels may be used for that area. Terminator DC Power Supply (PS302 ou DF50) DCS/PLC Interface (LC700) Terminator Impedance Conditioner Barreira (DF49,DC DF53 or PSI302P) COMM C1 C2 Output 2 Equipment with 4 – 20 mA Input DC Power Supply (see cargo line) DC barrier For C1 and C2 ou C3 e C4 The components inside the gray area are normally located in the control room C3 C4 Output 1 Equipment with 4 – 20 mA Input + 1 2 3 4 COMM. HART Communicator Figure 1.6 – FI302 Output Connections 1.4 + - FI302 Junction Box Installation Figure 1.7 shows a typical fieldbus network with equipments for different functions connected. DCS/PLC Terminator Interface DC Power Supply (PS302 or Df50) Terminator Impedance Conditioner (DF 49, DF53 or PSI302P) smar DC302-10 STCOM LOAD FLASH VEX A INA 0 INA 1 INA 2 INA 3 INA 4 INA 5 INA 6 INA 7 VEX B GND A INB 0 INB 1 INB 2 INB 3 INB 4 VEXA VEXB VEXOUT INA INB OUT 0 0 0 1 1 1 2 3 2 3 2 3 4 4 4 5 5 5 6 6 6 7 7 7 INB 5 INB 7 VEXOUT OUT 1 OUT 3 OUT 5 OUT 7 +BUS INB 6 GND B OUT 0 OUT 2 OUT 4 OUT 6 GNDOUT -BUS FI302 DC302 LD302 TP302 LD292 FY302 Figure 1.7 – Typical Fieldbus Equipment Network Power Consumption The FI302 converter must be properly powered as follows: * Minimum 9 V voltage; * 12 mA Operating Current (lq) The power supply must provid the minimum voltage wherever theFI302 is located in the H1 segment. An independent power supply shall be used to power the 4 – 20 mA equipments connected to the converter output. Low current consumption equipments should be used for intrinsically safety applications. Choose low resistance cables to reduce drop in voltage on the junction box and on each equipment. Terminator The terminators are impedances with the same values as the specific bus impedance to avoid signal reflection and, consequently their distortion or loss. Each bus segment must have only two terminators positioned on its ends. Some equipments, especially for power source, output/input, fieldbus test or PC simulation card, etc, include the option for an internal terminator connection. Before connecting a terminator to the bus, check if the equipment already has an internal terminator on one end, and install the other terminator. Each terminator has a 100 Ohm impedance and the equivalent impedance of both will be 50 Ohm. The terminator causes a 250- to-500 mV amplitude tension drop on the bus. Smar has the terminator model BT302. Cabling The FOUNDATION™ fieldbus protocol works with several types of cable and the best they are, the longer the lengths and the greater the number of equipments to be connected to it. Table 1.1 shows the regular cable types used when installing FOUNDATION™ fieldbus equipments and their characteristics. Pair Single Shielding Yes Twisted Yes Size Maximum Length Type 0,75 mm² 1900 m A Multicables yes yes 0,32 mm² 1200 m B Multicables no yes 0,13 mm² 400 m C Multicables yes no 1,25 mm² 200 m D Table 1.1 – Types of Cables. 1.5 FI302 - Operation and Maintenance Instruction Manual NOTE The length of non-twisted cables decreases regardless of their diameter and shielding (see D type data). It is recommended not to use these cables, but if you do, do not leave them too close to power cables or noisy equipments. The Fieldbus Foundation recommends the “A” type cable. Table 1.2 shows its main characteristics for a bus project. “A” TYPE CABLE Characteristic impedance on the 31,25 kHz frequency Maximum attenuation on the 39 kHz frequency Maximum capacitance outbalance for shielding Maximum DC resistance per conductor lenght Maximum propagation delay change Conductor transversal area 100 Ohm 20% 3 dB/km 2 nF/km 22 Ohm/km 1,7 us/km 0,75 mm2 Table 1.2 – “A Type” Cable Characteristics Total Cable Length The cable(s) total length vary (ries) according to its/their quality. The total length is the sum of the trunk and the spur lengths. For instance, use the diagram on figure 1.8 and the table 1.3 to determine the total length of a hypothetical bus. Trunk Terminator A Terminator B Spur 2 Spur 3 Spur 1 FY302 LD292 FI302 Figure 1.8 – Total Cable Length Segment A, B Trunk Length Spur 1 120 m Spur 2 40 m 240 m Spur 3 80 m Total 480 m Table 1.3 – Examples of Total Cable Lengths The cable types should combine according to the equation below: L1 / L1max + L2 / L2max + … < 1 Example: the network has the following cables: L1: is the type 1 cable length L2: is the type 2 cable length L1max: is the type 1 maximum cable length (see table 1.1). L2max: is the type 2 maximum cable length (see table 1.1). 1.6 Installation L1 = 1000 m of A type cable L2 = 100 m of B type cable 1000 / 1900 + 100 / 1200 = 0,61 The hypothetical combination on last example satisfies the above equation: 0,61 < 1 Cable shielding Shielding must be used, especially at noisy sites with high EMI/RFI near to the bus. Connect the spur shielding with the trunk shielding. The shielding should cover a minimum 90% cable length to guarantee good protection. Grounding The shielding is grounded only at the power supply negative terminal. Do not ground it at the other terminal, in order to avoid a secondary current circulation that could induce noise onto the bus. If the cable is not shielded install it on a tray and ground it only at one end. Do not use shielding as power conductor. Signal cables should NOT be grounded. Commissioning This item will explain the commissioning related to the configuration of the converter in the network. Before receiving or installing the converter and after the plant’s detailing project conclusion, it is suggested to initiate the offline configuration. Once accompli shed those steps proceed with the device configuration download. In FOUNDATION™ fieldbus the database configuration is made on user-defined tags with no association with the physical devices. Therefore, the devices must be associated to their respective configurations. Each device has a unique Device ID with 32 characters as hardware address, and meant to distinguish a device from another. This address is engraved on the circuit board by the manufacturer and cannot be changed. A field device is associated to its configuring system when correlates its configuration tag to the device ID. If the factory tag is identical to the configured tag on the configuring systems they will be automatically associated by the configurator system. Once it is connected to the network, the factory tag may be named, if not done yet. When all the devices are associated to their respective tags, the configuration may be completely or partially unloaded on the network equipments. If possible, use the configuring system to simulate the control and the operation. Then, you may start, stop and go through the control strategies and check if the plant is operating normally before the start-up. Commissioning stages Connect the electrically converter to the segment, so that the fieldbus will recognize it as an equipment with a non-commissioned tag; Use the configuration software to instantiate the newly-connected equipment. This creates ties between the physical equipment in the plant and the database configuration; Upload the equipment internal data on the configuration system and its strategy control on the equipment. NOTE The Fieldbus requires that the measuring unit be the same, both on the equipment transducer block and the function blocks, in order to avoid commissioning error. Use of non-preconfigured to devices Devices with non-configured tags are configured during commissioning. To do it, follow the procedure: Connect each adequate equipment to a fieldbus segment. The system will recognize them as non-commissioned equipments; Instantiate each equipment on the adequate segment in the configuration software; Name a TAG to the specific device according to the plant process flowchart (P&ID); Download the configuration to the equipment. 1.7 FI302 - Operation and Maintenance Instruction Manual Use of preconfigured equipments The devices with preconfigured tags identify themselves automatically with the configuration and save commissioning time. The user must simply install them and check when they appear on the system configurator screen. Each preconfigured device must be installed on the specific plant site where it was configured for. Linking Device The linking device, for instance, the Smar DFI302 or other interface, addresses all the devices on each network automatically. For practical purpose, the node address may be hidden, once it is not of interest to most users, whose interaction is based on tags. However, the node address is typically shown on the live list for the use of specialists. As a result, the Foundation Fieldbus devices may be commissioned directly from the control room. Once the device is connected to the network it will be detected in seconds. The devices may be connected or disconnected at any time without disturbing the network. Error monitoring and detection with Live List If the device does not appear on the configuration system live list, it most probably was connected to the wrong network or was not commissioned. In this case, it may be located in the live list of the others networks. Another possibility is that the device cable is not connected or the device is not operating properly. The live list, thus, is an excellent commissioning tool, as it facilitates checking the cable connection to the field devices. To make sure that a device was not mistaken for another on the same network or that it was installed at the wrong place, the device may be disconnected temporarily from the network, so that the user check if the right tag disappears from the live list. For more safety, use the configuration system to obtain detailed ID information from any device connected to the network. This information helps checking the tag, the description, the manufacturer, the type, the version and instrument general condition in order to confirm if it is the right device and if it is working properly. Installation in Hazardous Areas WARNING Explosions could result in death or serious injury, besides financial damage. Installation of this converter in explosive areas must be carried out in accordance with the local standards and the protection type adopted .Before continuing the installation make sure the certificate parameters are In accordance with the classified area where the equipment will be installed. The instrument modification or parts replacement supplied by other than authorized representative of Smar is prohibited and will void the certification. The converters are marked with options of the protection type. The certification is valid only when the protection type is indicated by the user. Once a particular type of protection is selected, any other type of protection can not be used. The electronic housing and the sensor installed in hazardous areas must have a minimum of 6 fully engaged threads. Lock the housing using the locking screw (Figure 1.3). The cover must be tighten with at least 8 turns to avoid the penetration of humidity or corrosive gases. The cover must be tighten until it touches the housing. Then, tighten more 1/3 turn (120) to guarantee the sealing. Lock the covers using the locking screw (Figure 1.3). Consult the Appendix A for further information about certification. 1.8 Installation Explosion/Flame Proof WARNING In Explosion-Proof installations the cable entries must be connected or closed using metal cable gland and metal blanking plug, both with at least IP66 and Ex-d certification. The standard plugs provided by Smar are certified according to CEPEL certificate. If the plug needs to be replaced, a certified plug must be used. The electrical connection with NPT thread must use waterproofing sealant. A non-hardening silicone sealant is recommended. For NEMKO ATEX certificate please to follow the installation guidelines in hazardous locations below: Group II Category 2G, Ex d, Group IIC, Temperature Class T6, EPL Gb U = 28VDC Ambient Temperature: -20 to 60ºC for T6 Environmental Protection: IP66/687 or IP66W/687W The electrical connection available are ½ - 14NPT and M20x1,5. Cable entries must be connected or closed using metal cable gland and metal blanking plug, both with at least IP66 and Ex-d certification or any appropriate ATEX approved metal cable gland and metal blanking plug. Do not remove the transmitter covers when power is ON. Intrinsically Safe WARNING In hazardous zones with intrinsically safe or non-incendive requirements, the circuit entity parameters and applicable installation procedures must be observed. To protect the application the transmitter must be connected to a barrier. Match the parameters between barrier and the equipment (Consider the cable parameters). Associated apparatus ground bus shall be insulated from panels and mounting enclosures. Shield is optional. If used, be sure to insulate the end not grounded. Cable capacitance and inductance plus Ci and Li must be smaller than Co and Lo of the associated Apparatus. It is not recommended to remove the transmitter cover when the power is ON. 1.9 FI302 - Operation and Maintenance Instruction Manual 1.10 Section 2 FUNCTIONAL DESCRIPTION Functional Description See Figure 2.1. MAIN CIRCUIT BOARD OUTPUT CIRCUIT BOARD POWER ISOLATION SUPLLY FIRMWARE DOWNLOAD INTERFACE LOCAL ADJUST CORRENT CONTROL 1 EPROM FLASH POWER SUPLLY CPU . EEPROM RAM SIGNAL SHAPING . RAM SIGNAL ISOLATION D/A CONTROLER COMUNICATION 2 D/A 3 D/A 4 DISPLAY BOARD DISPLAY CONTROLLER Figure 2.1 – FI302 Block Diagram D/A Receives signal from the CPU and converts it to an analog signal to be used by the current control Current Control Controls the channel current according to the data received from the CPU. Signal Isolator Isolates the data signal between the output and the CPU. Central Processing Unit (CPU), RAM and FLASH The CPU is the converter intelligent part, and is responsible for the management and operation of the blocks, auto-diagnosis and communication. The program is stored in FLASH memory. For the temporary storing of data there is a RAM. The RAM data will be lost if energy fails, although the device has a non-volatile EEPROM where the valid data are stored, as for calibration, configuration and identification. Communication Controller It controls the line activity, modulates and demodulates communication signals and inserts or delete initial and final delimiters. Power Supply Uses energy from the control loop to power the converter circuit. Power Insulation The power must be insulated as the output signals sent or received by the output 2.1 FI302 - Operation and Maintenance Instruction Manual Signal Conditioner Prepares the signals from the network or from the communication controller at acceptable levels by the communication controller or the fieldbus network, respectively. Display Controller Receives CPU data and controls the Liquid Crystal Display. Local Adjustment The power must be insulated once signals are sent and received by the output. 2.2 Section 3 OPERATION Liquid Crystal Display The liquid crystal display shows up to three variables that may be selected by the user. When two or three variables are chosen, the display will alternate the sampling from both with an interval of approximately 3 seconds. The LCD is made of a field with 4½ numerical digits, a field with 5 alphanumeric digits and an information field, as shown on Figure 3.1. INDICATES THAT THE COMMUNICATION IS ACTIVE INDICATES THAT THE OPERATION IS LOCALLY ADJUSTED MD F (t) 5 INDICATES THAT THE EEPROM IS ACTIVE AND THE OPERATION IS SAVED INDICATES THE POSSIBILITY FOR VARIABLE/MODE ADJUSTMENT/CHANGE VARIABLE FIELD MNEMONIC FIELD Figure 3.1 - Display Monitoring During normal operation, the FI302 is in monitoring mode and the indication alternates between the variables, as configured by the user. See Figure 3.2. The display shows the engineering units, values and parameters simultaneously with the majority of status indicators, depending on the local adjustment configuration. Figure 3.2 – Typical Monitoring Mode displaying the current inferior value, namely 4.0 mA. 3.1 FI302 - Operation and Maintenance Instruction Manual The monitoring mode is interrupted when the user makes the local adjustment. The display also shows messages and errors (See Table 3.1). DISPLAY DESCRIPTION Init , FI302 & Version The FI302 is powered and initiated Blk OOS OOS block not configured and link ineffective bad Communication or signal failure or bad signal Table 3.1 – Display Messages and Errors. 3.2 Section 4 CONFIGURATION The FI302 may be configured by any Foundation Fieldbus configuration tool or by an operational console. The FI302 has three output transducer blocks, one resource block, one display block, one diagnostic block and other instant able function blocks. This manual deals with the parameters of transducer blocks, display block and diagnostic block. The function blocks are described in the specific function block manual. Transducer Block The transducer block insulates the hardware input/output function block like sensors and actuators. The transducer blocks controls the input and output access through the specific manufacturer implementation. Usually, transducer block execute linearization function, characterization. The connection between the transducer block and function blocks is called channel. How to Configure a Transducer Block When instantiating the FI302 on the configuration tool, the transducer block is automatically instantiated. The Transducer block has an algorithm, an internal parameter group and a channel that connects it to the analog output function block. The algorithm describes how the transducer transfers information from the hardware input/output to other function blocks. The internal parameters, which cannot be linked to other blocks and published on the link via communication, define the user interface for the transducer block. They are divided in Standards that comply with the Foundation Fieldbus standard and those specified by manufacturers and made according to their needs. Every standard routine (e.g. calibration) follows a step by step method, which defines generally the rules that will help the user. The transducer, display and diagnostic blocks have several parameters that could be configured. Here will treat of the most usual. The others are similar. NOTE The parameters ending with an “n” mean that they are the same for the other groups, and are distinguished by their group number instead of the letter “n”. For the FI302 basic configuration, use the Transducer and Display blocks parameters. The Transducer Block parameters are configured as follows: MODE_BLOCK The MODE-BLOCK parameter configures the transducer block mode of operation. There are two options: Out of Service or AUTO (automatic). TERMINAL_NUMBER The TERMINAL_NUMBER parameter relates a value for the channel. It starts with 1 to the transducer number 1 and goes up to 3 to the transducer number 3. The FI302 has 3 current channels and the current value will be sent internally to a specific transducer output from the analog output function block. The number of the analog output block (AO) is related to the transducer terminal number (TERMINAL_NUMBER). The channels with numbers 1, 2, 3 correspond to the terminal block numbers 1, 2, 3. Select the combinations (1 - 1), (2 - 2), (3 - 3) for the channel and the terminal block number where the output will occur (channel number – terminal block number). The TERMINAL_NUMBER parameter chooses which of the three terminals of the terminal block will supply the output. At least one of them must be chosen or otherwise the FI302 will issue the error message “Blk_error”. 4.1 FI302 - Operation and Maintenance Instruction Manual Display Block The FI302 display block shows the variable chosen on monitoring mode or the option menu on the local adjustment mode. The display block is default-configured to make it possible to adjust the Upper Trim (UPPER) and the Lower Trim (LOWER), to monitor the input transducer output and check the Tag. The options of the FI302 local adjustment tree may be entirely configured by any fieldbus configuration tool. Use them for the configuration, but for certain operations the local adjustment is easier and faster, because it does not depend on network and communication connections. The parameter options to work with the local adjustment are: Mode Block, Output Monitoring, Tag Visualization and Tuning Parameter Adjustments. Before using the magnetic tool for local adjustment, use the fieldbus configuration tool to prepare the parameters that enable this operation. How to Configure a Display Block There are seven parameter groups indexed to the Block_Tag_Param_n parameter that may be preconfigured by the user to enable a configuration by local adjustment. If it is not necessary to display this group of tag-indexed parameters, write an invalid tag for the Block_Tag_Param_n parameter. With this procedure the equipment does not recognize it as a valid parameter nor the parameters indexed to it. The Display Block parameters are configured as follows: MODE_BLOCK The configuration is identical to the previous transducer block. BLOCK_TAG_PARAM_n The is the block tag where the parameter belongs. The FI302 enables inserting up to 7 block tags. Use a maximum of 32 characters. INDEX_RELATIVE_n This is the index related to the parameter that will be activated or visualized (0, 1, 2…6). See the Function Block manual to know the required indices, or visualize them on the configuration tool by opening the desired block. The FI302 accepts up to 7 parameter indices, configuring up to 7 parameter in the LCD. DISPLAY_REFRESH This parameter updates the new configuration. 4.2 Section 5 CALIBRATION If necessary, it is possible to adjust the FI302 output channel current. The trim adjustment is used if the indication on the transducer block output is different from the reference standard adopted. Possible causes are: The user Amperemeter is different from the plant standard. The converter had its default characterization altered by overload or by the time of use. To analyze the transducer output calibration, measure the channel output current with an accurate Amperemeter and compare it with the indication on the FI302. Adjust the trim in case of difference. The trim may be adjusted in two levels: Lower Trim: At the range lower level. Upper Trim: At the range upper level. These points define the linear output characteristics. The trim adjustments are independent. The Transducer Block parameters used for the FI302 calibration or current Trim are: CAL_POINT_HI, CAL_POINT_LO, FEEDBACK_CAL e CAL_CONTROL. Parameter description: CAL_POINT_HI This parameter configures the calibration range upper value. CAL_POINT_LO This parameter configures the calibration range lower value. FEEDBACK_CAL This is the current measured value used by the calibration method. It is used to apply the current trim. To apply the lower or upper values, write the value read by the amperemeter in the parameter during the calibration of the values. Repeat this operation until the measure is the same as the value read. See figure 5.1. CAL_CONTROL It enables and disables the calibration process with options Enable and Disable. After initiating the calibration method, the CAL_CONTROL parameter is used to return to the previous normal operation. The calibration will be enabled if the AO block output has a valid value and the status is different from “Bad”. If “Bad” appears, the message “Calibration Failed” will appear on the XD_ERROR parameter. Figure 5.1 shows how to connect the converter to calibrate its lower value on 4 mA and its upper value on 20mA. 5.1 FI302 - Operation and Maintenance Instruction Manual FI302 - + 1 2 3 4 COMM. + - LOCK Power Power Supply Supply Ampere Meter Amperimeter P 30 mA I Figure 5.1 – Current Measuring Connection Diagram There are two ways to apply the trim: use a magnetic tool for one of them and a fieldbus configuration tool, like the Smar Syscon for the other. It is possible to calibrate the conveter by means of parameters CAL_POINT_LO and CAL-POINTHI. Let’s take the lower value as an example: write 4 mA or the lower value in parameter CAL_POINT_LO. This parameter indicates where the converter should be when the setpoint lower value is 0%. The desired value should be entered. Figure 5.2 - Calibrating the CAL_POINT_LO – FI302 5.2 Calibração Always keep in mind that, simply by writing in this parameter, the trim procedure is initialized. Read the current in the multimeter and write that value in parameter FEEDBACK_CAL. Write in this parameter until it reads 4.0 mA or the lower value readout of the multimeter. This parameter should be set with the actual output current during the calibration procedure. The value should be entered here. Figure 5.3 - Feedback of Current Lo Value In order to end the trim procedure, choice DISABLE in the parameter CAL_CONTROL. This parameter ends the calibration procedure. The enable option indicates that the calibration process is being done. In order to finalize its procedure, the user should set it to disable. Figure 5.4 - Closing the Calibration Lo Procedure Let’s take the upper value as an example: Write 20 mA in parameter CAL_POINT_HI. Always keep in mind that, simply by writing in this parameter, the trim procedure is initialized. 5.3 FI302 - Operation and Maintenance Instruction Manual This parameter indicates where the converter should be when the setpoint is 100%. The desired value should be entered. Figure 5.5 - Calibrating the Cal Point Hi – FI302 Read the current in the multimeter and write that value in parameter FEEDBACK_CAL. Write in this parameter until it reads 20.00 mA or the upper value readout of the multimeter. This parameter should be set with the actual output current during the calibration procedure. The value should be entered here. Figure 5.6 - Feedback of CAL_POINT_HI – FI302 In order to end the trim procedure, choice DISABLE in the parameter CAL_CONTROL. 5.4 Calibração This parameter ends the calibration procedure. The enable option indicates that the calibration process is being done. In order to finalize its procedure, the user should set it to disable. Figure 5.7 - Closing the Calibration High Procedure The calibration will be enabled only if the output of AO block has a valid value and status different of "Bad" In this case, the following message can be seen in the parameter XD_ERROR. This parameter indicates de Error Code Operation associated to calibration procedure. It indicates that the calibration procedure was not sucessfull. Figure 5.8- Calibration Error Message – FI302 5.5 FI302 - Operation and Maintenance Instruction Manual 5.6 Section 6 MAINTENANCE NOTE Equipment installed in hazardous atmospheres must be inspected in compliance with the IEC60079-17 standard. Diagnostic Block – DIAG This transducer block provides the following characteristics: Online measuring time for the functional blocks execution; Hardware revision Firmware revision Equipment serial number Main board serial number The BEHAVIOR parameter defines the initial parameter values that will be used after block instantiation. The Adapted option selects a group of initial values more proper for the parameters, thus avoiding invalid values. The Spec option also allows defining initial values. Troubleshooting Physical Inspection After connecting the FI302 to the network, if it loses communication or slows down. e.g., due to multiple tentative communication, the error may be caused by poor installation procedure, by the configuration or by poor equipment performance. Causes for communication errors Badly fit connections Installation problems, repeated equipment addresses, bad configuration, etc. Terminator located at the wrong place, with or without terminator Power supply with too low or unstable voltage value Too long or too many Spurs Wrong ground or no ground Water infiltration in the equipment due to connections with wrong sealing and/or loose clamps Low isolation After carrying out the procedures for detecting network defects, act as follows: Insulate the segment or equipment that causes the problem Check if the polarity is correct Check is the address is correct Check the the Network integrity Check if the tension on the converter terminals is at least 9.5 V during communication Remove the equipment to a bench and test it. If it presents malfunctioning, contact Smar. Parameters used for Troubleshooting The FI302Transducer Block parameters used for troubleshooting are: BLOCK_ERR, XD_ERROR, FINAL_VALUE, RETURN e BACKUP_RESTORE Caution messages may appear on the status of the Return parameter or Block Error parameter, in given circumstances such as presented below, in two modes, OOS and AUTO. BLOCK_ERR This transducer BLOCK_ERR parameter shows the following errors: Block Configuration – When XD_SCALE has an improper range or unit; 6.1 FI302 - Operation and Maintenance Instruction Manual Output Failures – When the loop current open; Out of Service – When the block is on out of service mode (OOS) Limit Conditions for Calibration Lower 3.99 < NEW_LOWER < 11.5 mA, otherwise XD_ERROR = 22 Upper 12.5 < NEW_UPPER < 20.01 mA, otherwise XD_ERROR = 22 FINAL_VALUE The desired current value and the status written by the AO block; RETURN Current output value coming from the AO block; RETURN STATUS The transducer block Return Status indicates the following errors: Bad::NonSpecific:NotLimited – When the loop current is interrupted (open loop); XD_ERROR – This parameter is used to indicate the calibration status; BACKUP_RESTORE This parameter is used as backup or to recover configuration data. Table 6.1 has the information to determine the converter or network failures. NOTE It is recommended not to repair printed circuit boards. Keep spare parts or buy them from Smar, if necessary. Symptom PROBABLE SOURCE OF ERROR Diagnostic Converter Fieldbus Connections Check power supply polarity and continuity No turn on Power Supply Check power supply output. The voltage at the FI302 terminal block must be between 9 and 32 Vdc Electronic circuit failure Check circuit boards for defects and replace them for spare ones. Network Connection Check equipment, power supply and terminator connections. Network equipment impedance Check power supply and terminator impedance. No communication Converter configuration Check the converter communication parameters setting Network Configuration Check the network communications settings Electronic Circuit Failure Replace the main board and the input board matched pairs. Output Terminal Connection Check power supply, channels, terminal box polarity and continuity Incorrect Outputs (the power supply indicated aside is for 4-20 mA equipments) Power Supply Check power supply output. The FI 302 output voltage must be between 3 and 45 Vdc. Load Resistance Must be between 0 and 2000 Ohm. The higher value depends on the output power supply voltage. Calibration Check the converter calibration Table 6.1 – Failure Diagnostic. 6.2 Maintenance If the failure is not on table 6.1 use the Factory Init. The note below shows how to do it. NOTE Use factory init as the last option to recover control over the device when it presents problems related to function blocks or the communication. Only authorized personnel should do it and the converter must be offline. This procedure will enable the standard configuration values of the plant and disable the previous equipment configuration. To access the letters S and Z use two magnetic screwdrivers and loosen the screw that holds the identification plate. Proceed as follows: 1) Turn off the equipment and insert the magnetic screw drive handles in the openings S and Z and leave them there; 2) Power the equipment; When the display shows factory init, remove them and wait for the “S” symbol on the right upper corner to unlit, indicating the end of the operation. After running the factory init, download partially the configuration, which characterizes the equipment functional behavior on the fieldbus. Disassemble Procedure See Figure 6.1 for guidance on this procedure. Turn off the power supply before disassembling the converter. Exploded View 12 11 10 9 8 7 15 6 5 14 4 2 16 3 13 1 Figure 6.1 – FI302 Exploded View 6.3 FI302 - Operation and Maintenance Instruction Manual Electronic Circuit The main board (5) and output board (7) are matched pairs and must be replaced together should it be needed. Tighten the locking screw cap (8) located on the opposite side of the enclosure housing marked by "Field Terminals" and unscrew the cap (1) to access the display and circuit boards. To remove the motherboard (5) and the display, release the two screws (3) that hold them. Disconnect the display of the motherboard (5) and that the board's output signal. To remove the entry (7), loosen the screws (6) that hold the housing (9). CAUTION The boards have CMOS components that may be damaged by electrostatic discharges. Follow the right procedure for handling the CMOS components. Store the circuit boards in electrostatic-proof packaging. Assembly Procedure See Figure 6.1 for guidance on this procedure. Insert the output signal board (7) into the housing (9) and fasten it with its screws. Insert the main board (5) in the housing, making sure that all the pins are connected. The display may be mounted in any of the 4 possible positions (see Figure 6.2). The “▲” sign indicates the display upper position. Hold firmly the main board and the display with their screws (3). Fit the cover (1) according to the area classification and lock it with the locking screw (8). Figure 6.2 – Four Possible Indicator Positions Interchangeability The output and the main boards are matched pairs, once the calibration data for the output board is stored in the EEPROM of the main board. If for any reason, boards must be mixed to form a functional pair, a new calibration procedure must be done in order to guarantee the outputs accuracy. 6.4 Maintenance Spares SPARES ORDER CODE SD1 FDI302 DESCRIPTION Magnetic Screwdriver for local adjustment Field device interface Spare Part List SPARE PART LIST DESCRIPTION OF PARTS Cover Without Window (Included O-ring) Cover With Window (Included O-ring) Sealing ring (Note 2) Aluminum Housing Main Board Screw 316 Stainless Steel Housing Main Board Screw Aluminum 316 Stainless Steel Aluminum 316 Stainless Steel Cover, Buna-N Units with indicator Units without indicator Units with indicator Units without indicator Digital Indicator Main and Output Board Output Board Screw Aluminum Housing 316 Stainless Steel Housing Cover Locking Screw Housing, Aluminum (Note 1) Housing, 316 Stainless Steel (Note 1) 1/2 - 14 NPT M20 x 1.5 PG 13.5 DIN ½ - 14 NPT M20 x 1.5 PG 13.5 DIN Local Adjustment Protection Cap Identification Plate Screw Terminal Block Insulator External Ground Screw Terminal Block Insulator Screw Six-Sided Plug 1/2" NPT Internal BR Ex Six-Sided Plug 1/2" NPT Internal Six-Sided Plug M20 X 1.5 External BR Ex d Six-Sided Plug PG13.5 External BR Ex d Mounting Bracket for 2” Pipe (Note 3) 1. 2. 3. 4. Aluminum Housing 316 Stainless Steel Housing Bichromated Carbon Steel Bichromated 304 Stainless Steel Bichromated Carbon Steel Bichromated 304 Stainless Steel 316 Stainless Steel 316 Stainless Steel Carbon Steel 316 Stainless Steel Carbon Steel Bolts, Nuts, Washers and U-clamp in Stainless Steel POSITION CODE 1 e 15 1 e 15 1 1 2 3 3 3 3 4 5e7 6 6 8 9 9 9 9 9 9 10 11 12 13 14 14 16 16 16 16 16 16 - 204-0102 204-0105 204-0103 204-0106 204-0122 304-0118 304-0117 204-0118 204-0117 214-0108 324-0140 314-0125 214-0125 204-0120 324-0130 324-0131 324-0132 324-0133 324-0134 324-0135 204-0114 204-0116 314-0123 204-0124 304-0119 204-0119 400-0808 400-0809 400-0583-11 400-0583-12 400-0810 400-0811 214-0801 214-0802 - 214-0803 CATEGORY (NOTE 4) B A NOTE Includes terminal insulator, bolts (cover lock, grounding and terminal insulator), and I.D. plate without certification. Sealing orings are packed in dozens. Includes U-clamp, nuts, bolts and washers. Spare part list. For category “A” it is recommended to keep in stock 1 set for each 25 installed pairs, and for category “B”, 1 set/50 pairs. 6.5 Section 7 ADVANCED CONFIGURATION The transducer block allows some configurations through the parameters below that alter the current output curve. Parameter description CHARACTERIZATION_TYPE Indicates the characterization curve type; CURVE_BYPASS Enables and disables the characterization curve; CURVE_LENGHT Indicates the number of points the characterization curve; CURVE_X Characterization curve input points; CURVE_Y Characterization curve output points; Characterization Curve The transducer block also has a characterization curve, used to give a determined profile to the output. This is useful, for example, when the FI302 controls a valve with a non-linear feature. The characterization curve is applied to the input signal before being converted and sent to the analog output by the transducer. The CURVE_BYPASS parameter determines if the curve will be used or not. If the parameter is a true Bypass, the curve is not used and the input value is transmitted directly to the output current conversion routine. "True" means that the Characterization Curve will be bypassed. This value "False" enables the Characterization Curve. Figure 7.1 - Enabling the Characterization Curve The characterization curve has 8 points. Each point has two coordinates (X and Y). These two coordinates define the point location in the X – Y space, and the connection of adjacent points with a linear segment forms the characterization curve. Extreme points are extrapolated. 7.1 FI302 - Operation and Maintenance Instruction Manual This parameter determines the number of points valid and configured. The maximum number of points is 8. Figure 7.2 - Setting the Characterization Curve Length These points are numbered from 1 to 8 and are contained in the CURVE_X (abscissas) and CURVE_Y (ordinates) parameters. CURVE_X parameter requires points in crescent order, meaning that the subsequent points must be greater than the preceding ones, or the parameter will not be accepted. CURVE_Y parameter does not require this, and a non-monotonic curve is allowed. NOTE When writing on CURVE parameters remember to place the point coordinates in the correct order. This parameter defines the coordinates X The values should be configured in crescent order. Figure 7.3 - Configuring the Characterization Curve X points 7.2 Configuração Avançada This parameter defines the coordinates Y It is not necessary to follow any order. A monotone curve is allowed. FI2EM312 CDR Figure 7.4 - Configuring the Characterization Curve - Y points The Display Block allows configure up to three variables her they be shown in the digital indicator, or a tree with parameters that can be altered via local adjustment. This configuration is possible through procedures below: NOTE The parameters with “n” at its end mean that they are the same for other groups and are differentiated by their group number instead of the letter. The Display Block parameters are: SUB_INDEX_n, MNEMONIC_n, INC_DEC_n, DECIMAL_POINT_NUMBER_n e ACCESS_n SUB_INDEX_n To visualize a tag choose the relative index equal to zero and the sub index equal to 1 MNEMONIC_n This mnemonic identifies the parameter (16 characters maximum). Preferably, choose the mnemonic with up to 5 characters because it will be not necessary to rotate it on the display. INC_DEC_n It is the increase and the decrease in decimal units when the parameter is Float, Float Status, or Integer when the parameter is expressed in total units; DECIMAL_POINT_NUMBER_n Number of digits after the decimal point (0 to 3 decimal digits); ACCESS_n On Monitoring, the parameter enables only this option and on Action the function shows on the display the increment and decrement values. Definition of Parameters and Values Block_Tag_Param This is tag of the block to which the parameter belongs. Use up to a maximum of 32 characters. Index_Relative This is the index related to the parameter to be actuated or viewed (0, 1, 2…). Refer to the Function Blocks Manual to know the desired indexes, or visualize them on the SYSCON by opening the desired block. In case you wish to visualize a certain tag, opt for the index relative equal to zero, and for the subindex equal to one (refer to paragraph Structure Block in the Function Blocks Manual). Sub_Index 7.3 FI302 - Operation and Maintenance Instruction Manual This is the mnemonic for the parameter identification (it accepts a maximum of 16 characters in the alphanumeric field of the display). Choose the mnemonic, preferably with no more than 5 characters because, this way, it will not be necessary to rotate it on the display. Inc_Dec It is the increment and decrement in decimal units when the parameter is Float or Float Status time, or integer, when the parameter is in whole units. Decimal_Point_Numb. This is the number of digits after the decimal point (0 to 3 decimal digits). Access The access allows the user to read, in the case of the “Monitoring” option, and to write when "action" option is selected, then the display will show the increment and decrement arrows. Alpha_Num These parameters include two options: value and mnemonic. In option value, it is possible to display data both in the alphanumeric and in the numeric fields; this way, in the case of a data higher than 10000, it will be shown in the alphanumeric field. In option mnemonic, the display may show the data in the numeric field and the mnemonic in the alphanumeric field. In case you wish to visualize a certain tag, opt for the index relative equal to zero, and for the subindex equal to one (refer to paragraph Structure Block in the Function Blocks Manual). Figure 7.5- Parameters for Local Adjustment Configuration 7.4 Configuração Avançada Figure 7.6 - Parameters for Local Adjustment Configuration Figure 7.7 - Parameters for Local Adjustment Configuration 7.5 FI302 - Operation and Maintenance Instruction Manual Figure 7.8 - Parameters for Local Adjustment Configuration This parameter updates the local adjustment programming tree configured on each device. The option "update" should be selected in order to execute the upgrade of local adjustment programming tree. After its step all the parameters selected will be show on the LCD display. Figure 7.9 - Parameters for Local Adjustment Configuration 7.6 Section 8 LOCAL ADJUSTMENT When using the local adjustment for calibration, configure the display block to show the following parameters: CAL_POINT_HI (UPPER mnemonic), CAL_POINT_LO (LOWER mnemonic) and TAG (TAG mnemonic). The FI302 has three output transducers, although only the number 1 leaves Smar with factory configuration. To configure the other transducers to work with local adjustment use the configuration tool. NOTE The Trim mode is removed from local adjustment automatically if the magnetic tool is not used during approximately 16 seconds. Under its identification plate, the FI302 has two openings marked with S and Z at their side, giving access to two Reed Switch magnetic tools. They are activated when the magnetic tool is inserted in the orifices by its handle (See Figure 8.1). The magnetic tool permits adjusting most block parameters. Figure 8.1 – Local Adjustment Orifices. Jumper Configuration J1 and W1 Jumpers located on top of the main board must be coupled with the main board and the converter must have a display to show the local adjustment options. Table 8.1 shows the possible actions applied on openings S and Z when the local adjustment is enabled. OPENING ACTION S Selects the function shown on the display Z Initializes the local adjustment and moves through the available options. Table 8.1 – Function of the Openings on the Housing J1 Jumper Connection If J1 (see figure 8.2) is connected to the ON pins, it will be possible to simulate values and status using the SIMULATE parameter on the functional blocks. 8.1 FI302 - Operation and Maintenance Instruction Manual W1 Jumper Connection If W1 (see figure 8.2) is connected to ON, the display may perform configurations through local adjustment. OFF ON OFF ON LOC ADJ WR J1 W1 MAIN BOARD Figure. 8.2 – J1 and W1 Jumpers To calibrate the upper and lower current values by local adjustment follow the step-by-step example below: In order to initialize the local adjustment, insert the Insert it again in orifice S and wait for 5 secs. magnetic screwdriver. Insert it in orifice Z and wait for the letters MD to appear. Figure 8.3 – FI302 Step 1 8.2 Local Adjustment Remove it from opening S Insert it again on opening S. The abbreviations LOC ADJ will be displayed Figure 8.4 – FI302 Step 2 The first option on the tree is LOWER, with an arrow pointing upwards. An arrow pointing upwards () increments the value and an arrow pointing downwards () decrements the value. This parameter is used to calibrate the lower current value. In order to adjust the lower current value insert the tool in orifice S. Leave it there until the display shows 4,00 mA. If the values are different, move to FEED parameter and insert the mili-amperimeter current value to correct it. Insert the magnetic tool in the orifice Z. If it is the first option to be configured, the option TAG and its equivalent mnemonic will be displayed. Otherwise, the last option configured will be displayed. By keeping the tool in the opening, the local adjustment menu will rotate through the options on the local adjustment tree. Figure 8.5 – FI302 step 3 The UPPER option is used to calibrate the upper current value. Insert the magnetic tool in the S and leave it there until the display indicates 20,00 mA. Insert the miliamperimeter in the output terminal of the terminal block and measure the current. If the values are different, move to the FEED parameter and insert the current value read on the meter to correct it. In order to decrement the lower value, insert the magnetic tool in the orifice Z to shift the arrow to the downward position. Insert the tool in opening S and wait for the lower value to decrement to 4,99 mA. Insert the miliamperimeter in the terminal block output and measure the current. If the values are different, move to the FEED parameter and insert the miliamperimeter current value to correct it. Figure 8.6 – F302 Step 4 8.3 FI302 - Operation and Maintenance Instruction Manual In order to decrement the upper value, insert the magnetic tool in the Z to shift the arrow to the downward position. Insert the tool in the S and wait for the lower value to decrease to 20,00 mA. Insert the miliamperimeter in the output terminal of theterminal block and measure the current. If the values are different, go to the FEED parameter and insert the miliamperimeter current value to correct it. The FEED option allows the user to correct the current shown on the display, when the current is different from the standard value measured at the output. To implement the correction, read the current shown on the meter and apply this value. This option makes it possible to correct the calibration points on both Upper and Lower currents. An arrow pointing upwards () increments the current. Figure 8.7 – FI302 Step 5 Insert the magnetic tool in the S to shift the arrow downwards and decrement the calibration current according to the measured value. An arrow pointing downwards () willDecrement the current value. Figure 8.8 – FI302 Step 6 8.4 Section 9 TECHNICAL CHARACTERISTICS Functional Specification Output Signal Three 4 - 20 mA current output, external supply, common ground. Input Signal FOUNDATION™ fieldbus, digital, voltage mode 31.25 Kbit/s with bus power. Output Load Limitation External 3 - 45 Vdc output supply. Bus power 9 a 32 Vdc. Quiescent current consumption 12 mA. Non-intrinsic safety: 7.8 KHZ to 39 KHZ impedance must greater or equal to 3 K. With an intrinsic safety, the output impedance should be greater or equal to 400 , on the assumption that exists a power supply barrier of 7.8 KHz to 39KHz. 4½ digit LCD display. Power Supply Output Impedance Display Hazardous Area Certification Explosion-proof and intrinsically safe (ATEX (NEMKO and DEKRA EXAM), FM, CEPEL, CSA and NEPSI). Designed to comply with European Regulations (ATEX 94/9/EC and LVD 2006/95/EC). Temperature Limits Operation: -40 to 85 oC (-40 to 185 °F); Storage Display: -40 -10 to 120 oC to 60 oC (-40 to 250 °F); ( 14 to 140 °F) Operation; -40 to 85 oC (-40 to 185 °F) without damage. Humidity Limits 0 a 100% RH. Operation starting time Approximately 10 seconds. Update time Approximately 0.2 seconds. Performance Specification Accuracy 0.1%. Ambient Temperature Effect For a 10º C variation: ± 0.05% . Output Power Supply Effect ± 0.005% V. Vibration Effect Complies with SAMA PMC 31.1. Electromagnetic interference Effect Designed to comply with European Directive EMC 2004/108/EC. Electrical connection 1/2 -14 NPT, PG 13.5 or M20 x 1.5. Injected low copper aluminum and finishing with polyester painting or 316 stainless steel, with Buna N O-rings on cover. With an optional bracket, may be installed on a 2” pipe or on a wall or panel. Without display and mounting brackets: 0.80 Kg. Add 0.13 Kg for digital display. Add 0.60 Kg for mounting bracket. Physical Specification Material of Construction Mounting Weight 9.1 FI302 - Operation and Maintenance Instruction Manual Ordering Code MODEL FI302 TRIPLE CHANNEL FOUNDATION FIELDBUS TO CURRENT CONVERTER COD. Local Indicator 0 1 Without Indicator With Digital Indicator COD. Mounting Bracket 0 Without Bracket 1 Carbon Steel. Accessories: Carbon Steel 2 316 Stainless Steel. Accessories: AI316 7 Carbon Steel. Accessories: AI316 COD. Electrical Connections 0 1/2 - 14 NPT 1 1/2"- 14 NPT X 3/4 NPT (AI316) - with adapter 2 1/2" - 14 NPT X 3/4 BSP ( AI316) - with adapter 3 1/2" - 14 NPT X 1/2 BSP (AI316) - with adapter A M20 X 1.5 B PG 13.5 DIN SPECIAL OPTIONS COD. Housing H0 Aluminum (IP/TYPE) H1 316 Stainless Steel (IP/TYPE) H2 Aluminum for saline atmosphere (IPW/TYPE X) H3 316 Stainless Steel for saline atmosphere (IPW/TYPE X) COD. Identification Plate I1 FM: XP, IS, NI, DI I3 CSA: XP, IS, NI, DI I4 EXAM (DMT): Ex-ia; NEMKO: Ex-d I5 CEPEL: Ex-d, Ex-ia I6 Without Certification IE NEPSI: Ex-ia COD. Painting P0 Gray Munsell N 6,5 Polyester P3 Black Polyester P4 White Epoxi P5 Yellow Polyester P8 Without Painting P9 Safety Blue Epoxy - Electrostatic Painting PC Safety Blue Polyester - Electrostatic Painting PG Safety Orange Epoxi Paint - Electrostatic Painting COD. Output Signal T0 3 output - 4 to 20 mA COD. Tag Plate J0 With tag J1 Blank J2 According to user’s notes COD. Special ZZ FI302 1 1 0 * Leave it blank if not applicable 9.2 * * * * * * See Notes TYPICAL MODEL Appendix A CERTIFICATIONS INFORMATION Manufacturing Location Approved Smar Equipamentos Industriais Ltda – Sertãozinho, São Paulo, Brasil. European Directive Information Consult www.smar.com for the EC declarations of conformity for all applicable European directives and certificates. ATEX Directive 94/9/EC - “Electrical equipment and protective system intended for use in potential explosive atmospheres” The EC-Type Examination Certificate had been released by Nemko AS (CE0470) and/or DEKRA EXAM GmbH (CE0158), according to European Standards. The certification body for Production Quality Assurance Notification (QAN) and IECEx Quality Assessment Report (QAR) is Nemko AS (CE0470). LVD Directive 2006/95/EC - “Electrical Equipment designed for use within certain voltage limits” According the LVD directive Annex II, electrical equipment for use in an explosive atmosphere is outside the scope of this directive. According to IEC standard: IEC 61010-1:2010 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements. EMC Directive 2004/108/EC - “Electromagnetic Compatibility” The equipment is in compliance with the directive and EMC test was performed according to IEC standards: IEC61326-1:2005 and IEC61326-2-3:2006. To comply with the EMC directive the installation must follow these special conditions: Use shielded, twisted-pair cable for powering the instrument and signal wiring. Keep the shield insulated at the instrument side, connecting the other one to the ground. Hazardous Locations General Information Padrões Ex: IEC 60079-0 General Requirements IEC 60079-1 Flameproof Enclosures “d” IEC 60079-11 Intrinsic Safety “i” IEC 60079-26 Equipment with equipment protection level (EPL) Ga IEC 60079-27 Fieldbus intrinsically safe concept (FISCO) IEC 60529 Classification of degrees of protection provided by enclosures (IP Code) Customer responsibility: IEC 60079-10 Classification of Hazardous Areas IEC 60079-14 Electrical installation design, selection and erection IEC 60079-17 Electrical Installations, Inspections and Maintenance Warning: Explosions could result in death or serious injury, besides financial damage. Installation of this instrument in an explosive environment must be in accordance with the national standards and according to the local environmental protection method. Before proceeding with the installation match the certificate parameters according to the environmental classification. General Notes: Maintenance and Repair The instrument modification or replaced parts supplied by any other supplier than authorized representative of Smar Equipamentos Industriais Ltda is prohibited and will void the Certification. A.1 FI302 – Operation and Maintenance Instruction Manual Marking Label Once a device labeled with multiple approval types is installed, do not reinstall it using any other approval types. Scratch off or mark unused approval types on the approval label. For Ex-i protection application Connect the instrument to a proper intrinsically safe barrier. Check the intrinsically safe parameters involving the barrier, equipment including the cable and connections. Associated apparatus ground bus shall be insulated from panels and mounting enclosures. When using shielded cable, isolate the not grounded cable end. Cable capacitance and inductance plus Ci and Li must be smaller than Co and Lo of the Associated Apparatus. For Ex-d protection application Only use Explosion Proof/Flameproof certified Plugs, Adapters and Cable glands. As the instrument is non-ignition capable under normal conditions, the statement “Seal Not Required” could be applied for Explosion Proof version regarding to electric conduits connection. (CSA Approved) In an Explosion-Proof/Flame-Proof installation, do not remove the instrument housing covers when powered on. Electrical Connection In Explosion-Proof installations the cable entries must be connected through conduit with sealed unit or closed using metal cable gland or closed using metal blanking plug, all with at least IP66 and Ex-d certification. For enclosure with saline environment protection (W) and ingress protection (IP) applications, all NPT thread parts must apply a proper water-proof sealant (a non-hardening silicone group sealant is recommended). For Ex-d and Ex-i protection application The transmitter has a double protection. In this case the transmitter shall be fitted with appropriate certified cable entries Ex-d and the electric circuit supplied by a certified diode safety barrier as specified for the protection Ex-ia. Environmental Protection Enclosure Types (Type X): Supplementary letter X meaning special condition defined as default by Smar the following: Saline Environment approved - salt spray exposed for 200 hours at 35ºC. (Ref: NEMA 250) Ingress protection (IP W): Supplementary letter W meaning special condition defined as default by Smar the following: Saline Environment approved - salt spray exposed for 200 hours at 35ºC. (Ref: IEC60529) Ingress protection (IP x8): Second numeral meaning continuous immersion in water under special condition defined as default by Smar the following: 1 Bar pressure during 24hours. (Ref: IEC60529) Hazardous Locations Approvals CSA (Canadian Standards Association) Class 2258 02 – Process Control Equipment – For Hazardous Locations (CSA1002882) Class I, Division 1, Groups B, C and D Class II, Division 1, Groups E, F and G Class III, Division 1 Class I, Division 2, Groups A, B, C and D Class II, Division 2, Groups E, F and G Class III CLASS 2258 03 - PROCESS CONTROL EQUIPMENT – Intrinsically Safe and Non-Incendive Systems - For Hazardous Locations (CSA 1002882) Class I, Division 2, Groups A, B, C and D Model FI302 Fieldbus Converter; supply 12-42V dc, 4-20mA; Enclosure Type 4/4X; non-incendive with Fieldbus / FNICO Entity parameters @ Terminals + and - : Vmax =24V, Imax =570 mA, Pmax = 9.98 W, Ci = 5 nF, Li = 12uH; @ Terminals 1 - 4: Vmax =30V, Imax =110mA, Ci = 5 nF, Li = 12uH; when connected through CSA Certified Safety Barriers as per SMAR Installation drawing 102A0559; Temp. Code T3C. Class 2258 04 – Process Control Equipment – Intrinsically Safe Entity – For Hazardous Locations (CSA 1002882) Class I, Division 1, Groups A, B, C and D Class II, Division 1, Groups E, F and G Class III, Division 1 FISCO Field Device A.2 Certifications Information Model FI302 Fieldbus Converter; supply 12-42V dc, 4-20mA; Enclosure Type 4/4X; Intrinsically safe with Fieldbus/FISCO Entity parameters @ Terminals + and -: Vmax = 24 V, Imax = 380 mA, Pi = 5.32 W, Ci = 5 nF, Li = 12 uH; @ Terminals 1 – 4: Vmax = 30 V, Imax = 110 mA, Ci = 5nF, Li = 12 u H; when connected through CSA Certified Safety Barriers as per Smar Installation Drawing: 102A0559; Code T3C. Note: Only models with stainless steel external fittings are Certified as Type 4X. Special conditions for safe use: Temperature Class T3C Maximum Ambient Temperature: 40ºC (-20 to 40 ºC) FM Approvals (Factory Mutual) Intrinsic Safety (FM 0D7A9.AX) IS Class I, Division 1, Groups A, B, C and D IS Class II, Division 1, Groups E, F and G IS Class III, Division 1 Explosion Proof (FM 0D7A9.AX) XP Class I, Division 1, Groups A, B, C and D Dust Ignition Proof (FM 0D7A9.AX) DIP Class II, Division 1, Groups E, F and G DIP Class III, Division 1 Non Incendive (FM 0D7A9.AX) NI Class I, Division 2, Groups A, B, C and D Environmental Protection (FM 0D7A9.AX) Option: Type 4X/6/6P or Type 4/6/6P Special conditions for safe use: Entity Parameters Fieldbus Power Supply Input (report 3015629): Vmax = 24 Vdc, Imax = 250 mA, Pi = 1.2 W, Ci = 5 nF, Li = 12 uH Vmax = 16 Vdc, Imax = 250 mA, Pi = 2 W, Ci = 5 nF, Li = 12 uH 4-20 mA Current Loop: Vmax = 30 Vdc, Imax = 110 mA, Pi = 0,825 W, Ci = 5 nF, Li = 12 uH Temperature Class T4 Maximum Ambient Temperature: 60ºC (-20 to 60 ºC) NEMKO (Norges Elektriske MaterielKontroll) Explosion Proof (Nemko 13 ATEX 1570) Group II, Category 2 G, Ex d, Group IIC, Temperature Class T6, EPL Gb Ambient Temperature: -20 to 60 ºC Environmental Protection (Nemko 13 ATEX 1570) Options: IP66W/68W The Essential Health and Safety Requirements are assured by compliance with: EN 60079-0:2012 General Requirements EN 60079-1:2007 Flameproof Enclosures “d” EXAM (BBG Prüf - und Zertifizier GmbH) Intrinsic Safety (DMT 00 ATEX E 065) - In Progress Group I, Category M2, Ex ia, Group I, EPL Mb Group II, Category 2 G, Ex ia, Group IIC, Temperature Class T4/T5/T6, EPL Ga FISCO Field Device Supply circuit for the connection to an intrinsically safe fieldbus-circuit: Ui = 24Vdc, Ii = 380 mA, Pi = 5.32 W, Ci ≤ 5 nF, Li = neg Parameter of the supply circuit complies with FISCO model according to EN 60079-27: 2008. A.3 FI302 – Operation and Maintenance Instruction Manual Output-signal-circuits; three 4-20 mA current sinks with common ground for external intrinsically safe supply Effective internal capacitance Ci negligible Effective internal inductance Ci negligible Safety-relevant maximum values for certified intrinsically safe 4-20 mA current loop circuits as a function of ambient temperature and temperature class; Max. Ambient temperature Ta Temperature Class Voltage DC Ui Current Ii Power Pi 60ºC T4 28 V 93 mA 750 mW 50ºC T5 28 V 93 mA 750 mW 40ºC T6 28 V 93 mA 570 mW The signal outputs are safely galvanically separated from the fieldbus circuit. Ambient Temperature: -40ºC ≤ Ta ≤ 60ºC The Essential Health and Safety Requirements are assured by compliance with: EN 60079-0:2009 General Requirements EN 60079-11:2007 Intrinsic Safety “i” EN 60079-26:2007 Equipment with equipment protection level (EPL) Ga EN 60079-27:2008 Fieldbus intrinsically safe concept (FISCO) CEPEL (Centro de Pesquisa de Energia Elétrica) Intrinsic Safety (CEPEL 97.0019X) Ex ia, Group IIC, Temperature Class T4/T5, EPL Ga FISCO Field Device Entity Parameters: Pi = 5.32 W, Ui = 30V, Ii = 380 mA, Ci = 5.0 nF, Li = Neg Ambient Temperature: -20 to 65ºC for T4 -20 to 50ºC for T5 Explosion Proof (CEPEL 97.0091) Ex d, Group IIC, Temperature Class T6, EPL Gb Maximum Ambient Temperature: 40ºC (-20 to 40 ºC) Environmental Protection (CEPEL 97.0019X and CEPEL 97.0091) Options: IP66/68W or IP66/68 Special conditions for safe use: The certificate number ends with the letter "X" to indicate that for the version of FIELDBUS to current Converter model FI302 equipped with housing made of aluminum alloy, only can be installed in "Zone 0" if is excluded the risk of occurs impact or friction between the housing and iron/steel itens. The Essential Health and Safety Requirements are assured by compliance with: ABNT NBR IEC 60079-0:2008 General Requirements ABNT NBR IEC 60079-1:2009 Flameproof Enclosures “d” ABNT NBR IEC 60079-11:2009 Intrinsic Safety “i” ABNT NBR IEC 60079-26:2008 Equipment with equipment protection level (EPL) Ga IEC 60079-27:2008 Fieldbus intrinsically safe concept (FISCO) ABNT NBR IEC 60529:2005 Classification of degrees of protection provided by enclosures (IP Code) NEPSI (National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation) Intrinsic Safety (NEPSI GYJ071324) Ex ia, Group IIC, Temperature Class T4/T5/T6 Supply terminals entity parameters: A.4 Certifications Information Ui = 16 V, Ii = 250 mA, Pi = 2.0 W, Ci = 5 nF, Li = 0 Terminals 1-4: Pi = 0.75 W, Ui = 28 V, Ii = 93 mA, Ci = 0 nF, Li = 0 Ambient Temperature: T4 40 ºC for Pi = 2.0W, Pi = 750 mW T4 60 ºC for Pi = 865 mW, Pi = 750 mW T5 40 ºC for Pi = 990 mW, Pi = 750 mW T6 40 ºC for Pi = 630 mW, Pi = 570 mW Identification Plate and Control Drawing CSA (Canadian Standards Association) FM Approvals (Factory Mutual) NEMKO (Norges Elektriske MaterielKontroll) / EXAM (BBG Prüf - und Zertifizier GmbH) A.5 FI302 – Operation and Maintenance Instruction Manual CEPEL (Centro de Pesquisa de Energia Elétrica) NEPSI (National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation) A.6 Certifications Information Canadian Standards Association (CSA) A.7 FI302 – Operation and Maintenance Instruction Manual A.8 MARCIAL MISSAWA 20 10 08 20 10 08 MARCIAL MISSAWA 6 16 07 07 16 07 07 MOACIR CASSIOLATO 5 07 05 03 07 05 03 MOACIR CASSIOLATO 4 08 02 00 08 02 00 REV. DESIGN APPROVED 7 ALT DE 0049/08 AREA DRAWING + DESIGN - + VERIFIED MELONI M.MISSAWA SINASTRE ALT DE 0004/07 28 03 95 28 03 95 28 03 95 ALT DE CUSTOMER: 0043/03 EQUIPMENT: FI302/303 ALT DE 0015/00 CONTROL DRAWING 28 03 FIELDBUS GROUND BUS 4 to 20mA I.S. BARRIER FIELDBUS I.S. BARRIER OPTIONAL SHIELDING APPROVAL CONTROLLED BY C.A.R. APPROVED PELUSO 95 : DRAWING N. Voc Isc Po 24V 250mA 1,2W Voc Isc Po CABLE INDUCTANCE +12uh La FIELDBUS CABLE CAPACITANCE +5nF Ca GROUPS A,B,C,D,E,F & G CLASS I,II,III DIV.1 16V 250mA 2W 4-20mA Voc 30V Isc 110mA ENTITY PARAMETERS FOR ASSOCIATED APPARATUS POWER SUPPLY - POWER SUPPLY ASSOCIATED APPARATUS EARTH IN EXCESS OF 250VAC OR 250VDC. SOURCE OF POTENTIAL IN RELATION TO NORMAL OR ABNORMAL CONDITIONS, A BE SUPPLIED FROM, NOR CONTAIN UNDER UNSPECIFIED, EXCEPT THAT IT MUST NOT SAFE AREA APPARATUS NON HAZARDOUS OR DIVISION 2 AREA TRANSMITTER SPECIFICATION MUST BE IN ACCORDANCE TO APPROVAL LISTING. 2- WIRES: TWISTED PAIR, 22AWG OR LARGER. SHIELD IS OPTIONAL IF USED, BE SURE TO INSULATE THE END NOT GROUNDED. 56- 4-20mA Ci=5nF Li=12uH Vmax 30V Imax 110mA FIELDBUS Ci=5nF Li=12uH Vmax 24V Imax 250mA ENTITY VALUES: CLASS I,II,III DIV.1, GROUPS A,B,C,D,E,F & G MODELS FI302 AND FI303 - SERIES FIELDBUS APPROVAL. PREVIOUS MANUFACTURER BE SUBSTITUTED WITHOUT COMPONENTS CAN NOT CABLE CAPACITANCE AND INDUTANCE PLUS Ci AND Li MUST BE SMALLER THAN Ca AND La OF THE ASSOCIATED APPARATUS. ASSOCIATED APPARATUS GROUND BUS RESISTANCE TO EARTH MUST BE SMALLER THAN 1(ONE) OHM, IF NOT ISOLATED. 4- 7- ASSOCIATED APPARATUS GROUND BUS TO BE INSULATED FROM PANELS AND MOUNTING ENCLOSURES. 3- FM INSTALLATION MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70) AND ANSI/ISA-RP12.6 HAZARDOUS AREA 1- REQUIREMENTS: Certifications Information Factory Mutual (FM) FM APPROVED smar O.S. 102A0080 REV SH.01/01 07 A.9 FI302 – Operation and Maintenance Instruction Manual A.10 Appendix B SRF – Service Request Form Converter from Fieldbus to 4-20mA GENERAL DATA Model: Serial Number: TAG: FI302 ( ) FI303 ( ) ______________________________________________________________________________________________________ ______________________________________________________________________________________________________ How many channels are used in IF? 1( ) Configuration: Magnetic Tool ( ) 2( ) PC ( ) 3( ) Software: _____________ Version: ________________ Other: _____________________ INSTALLATION DATA Type/Model/Manufacturer of device connected to the channel 1: Type/Model/Manufacturer of device connected to the channel 2: Type/Model/Manufacturer of device connected to the channel 3: _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ PROCESS DATA Hazardous Area Classification: ( ) Yes, please specify: ______________________________________________________________________________ ( ) No More details: _______________________________________________________________________________________ Types of Interference Without interference ( ) presents in the area: Ambient Temperature: Temperature ( ) Vibration ( ) Others: ____________________________________ From __________ºC up to __________ºC OCCURRENCE DESCRIPTION _____________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________ SERVICE SUGGESTION Adjustment ( ) Cleaning ( ) Preventive Maintenance ( ) Update / Up-grade ( ) Other: _______________________________________________________________________________________________________________ USER INFORMATION Company: ___________________________________________________________________________________________________________ Contact: _____________________________________________________________________________________________________________ Title: ________________________________________________________________________________________________________________ Section: _____________________________________________________________________________________________________________ Phone: _________ _________________________ _________ _________________________ E-mail: ________________________________________________________________________ Extension: __________________________ Date: ______/ ______/ _________________ For warranty or non-warranty repair, please contact your representative. Further information about address and contacts can be found on www.smar.com/contactus.asp. B.1 FI302 – Operation, Maintenance and Instructions Manual Returning Materials Should it be necessary to return the converter to Smar, simply contact your local Smar office informing the defective equipment serial number and dispatch it to our factory. For easier analysis and faster solution of the problem, the returned material should include the documentation with a description of the failure observed in the field and the circumstances that caused it. Other information, such as the installation site, type of measure taken and the process conditions are also important for a prompt evaluation. B.2