WNA en Wireless Router

Transcription

WNA en Wireless Router
WNA
Version 1.00 EN
Wireless Router
Installation manual
en
Delivery scope
The delivery scope of the device includes the following parts:
 Wireless Router WNA (TL-MR3020)
 Power pack
 USB cable
 Ethernet LAN cable
 A CD with: Operating instructions (English)
 Installation manual (English)
Displays, operating elements, connections
Power
Internet
WLAN
Ethernet
WPS/Reset
LED
Status
Power
On
The router is supplied with electrical voltage.
Off
The router is switched off.
On
The router is connected with the Internet but no data is transmitted.
Internet
Flashes
WLAN
The router is connected with the Internet and data is transmitted.
Off
The router is connected with the Internet.
On
The WLAN interface is activated.
Flashes
Ethernet
Importance
The WLAN interface is activated and data is transmitted.
Off
The WLAN interface is deactivated.
On
There is an inactive connection with the port.
Flashes
Off
Data is transmitted to the port.
The port is not connected.
Reset: If the key flashes for longer than 10 seconds, the router will carry out a reset.
3G/4G-USBmodem connection
Mini USB port (DC)
Ethernet port
Operating mode selector switch




3G/4G USB port: Connection for the USB modem.
Mini USB port: Connection to the power supply.
Ethernet port: This port is used as a LAN connection.
Operating mode selector switch: Selection of router modes. If the operating mode is changed
during operation, the router will be restarted.
The router information is on a label on the side of the router: MAC address, key, SSID and the default
settings: IP address, user name, password.
This installation manual describes only two operating modes that are relevant for the operation of the
routers in connection with the interface C.M.I.
Operation in 3G/4G router mode
As 3G/4G router (with 3G/4G modem/board), this router can be connected with a 3G mobile phone
network and provided its Internet connectivity with an individual WLAN SSID.
CMI
Connection to the network
A WLAN connection is used to configure the router in the example. (You can also use a LAN connection for the configuration.)
Windows XP and Windows 7
1. On the task bar, click on the icon
(Windows XP) or
(Windows 7/8)
2. Click on Update network list and select the WLAN network of the router and click on Connect.
The standard SSID (network name) of the router is TP-LINK_POCKET_3020_xxxxxx. (The
values xxxxxx are the last 6 digits of the MAC address of the router.)
If the WLAN network of the router shows Connected, you are successfully connected with the
RASPT router.
Windows XP
Windows 7
Windows 8.x
1. The key combination Windows+I takes you to the settings.
2. The WLAN symbol
takes you to the list of all networks that you receive.
3. Tap or click on the name of the network that you want to establish a connection with and then
tap or click on “Establish connection”.
The network name of the router is
here:
TP-LINK_POCKET_3020_xxxxxx
Router configuration
1. Open a web browser and enter the address http://192.168.0.254 in the address line and per
Enter.
2. The log-in window shown in the figure below appear. Enter admin as user name and password. Click on OK or press Enter.
3. Before you proceed with the configuration, check the status of 3G/4G in Status to see if your
3G/4G modem stick has been detected.
4. In the menu, go to Quick Setup and click on Next.
5. Click on Next. The Internet access page appears. Select 3G/4G Only (recommended) and
click on Next.
6. Enter your access data in this page and click on Next.
If you cannot find your provider in the menu, set Set the Dial Number, APN, user name and
password manually to manual entry and enter your access data according to the information
of your provider (ISP).
7. The WLAN setting are now displayed.
You can leave the settings or change the “Wireless Network Name“ (ISS) and/or the password. Click on Next.
8. Click on Reboot to accept the new WLAN configuration and to complete the Quick Setup. (If
the WLAN settings were not changed, click on Finish to complete the quick installation”.)
9. After the restart, connect with the network again (see chapter “Connection to the network”)
10. You can now connect the C.M.I. with the router. The C.M.I. must be restarted subsequently.
Operation in AP (“Access Point”) mode
Configured as Client, the router how behaves like a WLAN card and thus does integrates non-WLANcapable Ethernet devices in a wireless network.
CMI
TCP/IP configuration
A LAN connection is used to configure the router in the example. (You can also use a WLAN connection for the configuration.)
1. Windows XP: Start → Settings → Control panel → Network connections;
for Windows 7: Start → Control panel → Network and Internet → Network and release
center → Change adapter settings;
for Windows 8: Windows- + C key → tap/click on Search → enter the text Control panel in
the search field and then tap/click on Control panel. → Network and Internet → Network
and release center → Change adapter settings
2. Right-click on the LAN connection and select Properties.
3. In Windows XP, double-click on the Internet protocol (TCP/IP);
In Windows 7 and Windows 8.x, double-click on the Internet protocol version 4 (TCP/IPv4).
Windows XP
Windows 7 / Windows 8.x
4. Select the following IP address and enter an IP address with the format 192.168.0.x. x is a
number from 1 to 253 and the subnet mask is 255.255.255.0. Click on OK.
Router configuration
1. Open a web browser and enter the address http://192.168.0.254 in the address line and per
Enter.
2. Enter admin as user name and as password. Click on OK or press Enter.
3. In the menu, go to Quick Setup and click on Next.
4. Select the wireless operation mode type “Client” and click on Next.
5. The following window appears. Enter the network name (SSID) and the security settings.
Then click on Next.
The “security mode” must be set precisely according to the setting of the existing WLAN.
None means that the router is working completely without encryption. This way, anyone within
reach can connect with the router.
6. Click on Reboot to restart the router and to accept the settings.
After the router restart, change the TCP/IP settings of your computer back to Automatically
get IP address and Automatically get DNS server address and establish the network connection.
7. You can now connect the C.M.I. with the router. The C.M.I. must be restarted subsequently.
We reserve the right to make technical changes.
© 2014
EC- DECLARATION OF CONFORMITY
Document- Nr. / Date:
TA12032 / 27.06.2014
Company / Manufacturer:
Technische Alternative elektronische SteuerungsgerätegesmbH.
Address:
A- 3872 Amaliendorf, Langestraße 124
This declaration of conformity is issued under the sole responsibility of the manufacturer (or
ins
Product name:
WNA
Product brand:
Product description:
Technische Alternative GmbH.
Wireless Router
The object of the declaration described above is in conformity with Directives:
1999/5/EC, 2004/108/EC, 2006/95/EC, 1999/519/EC, 2011/65/EU
Employed standards:
ETSI EN 300 328 V1.7.1: 2006, ETSI EN 301 489-1 V1.8.1:2008& ETSI EN 301 489-17 V2.1.1:2009,
EN 55022:2010, EN 55024:2010, EN 61000-3-2:2006+A1:2009+A2:2009, EN 61000-3-3:2008,
EN60950-1:2006+A11:2009+A1:2010+A12:2011, EN 62311:2008, EN 301 893, EN 302 502
Position of CE - label: On packaging, manual and type label
Issuer:
Technische Alternative elektronische SteuerungsgerätegesmbH.
A- 3872 Amaliendorf, Langestraße 124
This declaration is submitted by
Kurt Fichtenbauer, General manager,
27.06.2014
This declaration certifies the agreement with the named standards, contains however no warranty of
characteristics.
The security advices of included product documents are to be considered.
Guarantee conditions
Note: The following guarantee conditions do not in any way limit the legal right to a guarantee, rather expand your rights as a consumer.
1. The company Technische Alternative elektronische Steuerungsgerätegesellschaft m. b. H.
provides a two-year guarantee from the date of purchase by the end consumer for all the devices and parts which it sells. Defects must be reported immediately upon detection and within
the guarantee period. Technical support knows the correct solution for nearly all problems. In
this respect, contacting us immediately will help to avoid unnecessary expense or effort in
troubleshooting.
2. The guarantee includes the free of charge repair (but not the cost of on site fault-finding, removal, refitting and shipping) of operational and material defects which impair operation. In the
event that a repair is not, for reasons of cost, worthwhile according to the assessment of
Technische Alternative, the goods will be replaced.
3. Not included is damage resulting from the effects of overvoltage or abnormal ambient conditions. Likewise, no guarantee liability can be accepted if the device defect is due to: transport
damage for which we are not responsible, incorrect installation and assembly, incorrect use,
non-observance of operating and installation instructions or incorrect maintenance.
4. The guarantee claim will expire if repairs or actions are carried out by persons who are not authorised to do so or have not been so authorised by us or if our devices are operated with
spare, supplementary or accessory parts which are not considered to be original parts.
5. The defective parts must be sent to our factory with an enclosed copy of the proof of purchase and a precise description of the defect. Processing is accelerated if an RMA number is
applied for via our home page www.ta.co.at. A prior clarification of the defect with our technical
support is necessary.
6. Services provided under guarantee result neither in an extension of the guarantee period nor
in a resetting of the guarantee period. The guarantee period for fitted parts ends with the
guarantee period of the whole device.
7. Extended or other claims, especially those for compensation for damage other than to the device itself are, insofar as a liability is not legally required, excluded.
Legal notice
These assembly and operating instructions are protected by copyright.
Use outside the copyright requires the consent of the company Technische Alternative elektronische
Steuerungsgerätegesellschaft m. b. H.. This applies in particular to reproductions, translations and
electronic media.
elektronische Steuerungsgerätegesellschaft m. b. H.
A-3872 Amaliendorf Langestraße 124
Tel +43 (0)2862 53635
Fax +43 (0)2862 53635 7
E-Mail: [email protected]
--- www.ta.co.at ---