【 Operation Manual 】 MFC power supply meter MODEL:SP-832 Series
Transcription
【 Operation Manual 】 MFC power supply meter MODEL:SP-832 Series
【 Operation Manual 】 MFC power supply meter MODEL:SP-832 Series Series MFC Terminal power out block’s cover SP-832 Function Display with power supply No code ±15V 200mA S24 +24V 250mA No code C No attachment Terminal cover (Attachment) Thank you for purchasing this UINICS product. Please read this Operation Manual carefully in order to ensure that you use the power supply safely and correctly. ! Caution For professional use only or designed for use by a licensed electrician only. ! Attention Check if the label (model name) of the unit and your desired product specification correspond before use. UINICS CO.,LTD. 【 6th. : May. 15, 2014 】 @SP-832 E (6) ■ Precautions Please read this Operation Manual including the following precautions carefully to ensure safe use of your Power Supply. ! Caution Do not use this product for applications outside of the product specifications. ! Caution User-conducted alterations and modifications of the unit should not be performed as they may impair functioning or cause failure and accidents. ! Caution Avoid exposing the unit to direct sunlight, environments exceeding the specified temperature / humidity conditions, or condensation. ! Caution Do not use the unit in environments containing flammable gases or combustibles. ! Caution Do not subject the unit to strong vibrations or shocks. Do not give mechanical shock of IEC62262 (energy 1J or more) to the front panel. ! Caution Do not allow metallic debris, dust, or moisture to penetrate the unit. ! Caution Since there is no power switch in this machine, it will be in an operating state immediately after power supply impression. Equipment to be incorporated in the side of our customers, please be prepared to supply the switch and circuit breaker which adapted to IEC/EN60947-1 or IEC/EN60947-3 standard in the position that you can operate immediately in emergency. Moreover, please specify that they are interrupting devices. ! Caution Use the temperature rating 72 ℃ or more power cord. ! Caution Do not touch the terminal while operating. It gets an electric shock. ! Caution Devices to be connected to each terminal of the terminal block, use the one that is properly isolated from hazardous live parts. ! Caution This machine is designed to be used with the panel mounted. When used in a state other than that, there is a possibility that the protective device is provided with is impaired. ! Caution Wipe dirt with a soft cloth on the front panel. Do not use solvents such as alcohol or thinner. ■ Contents 1.About confirmation of an attachment and a guaranteed period・・・・ page.1 2.Introduction ・・・・・・・・・・・・・・・・・・・・・・・・・・・ page.2 3.Specifications ・・・・・・・・・・・・・・・・・・・・・・・・・・ page.3-4 4.Panel mounting method ・・・・・ ・・・・・・・・・・・・・・・・・ page.4 5.Names and functions of components on front ・・・・・・・・・・・・ page.5 6.Connecting terminal boards ・・・・・・・・・・・・・・・・・・・・ page.6 7.MFC connection connectors・・・・・・・・・・・・・・・・・・・・・ page.7 8.External dimensions and panel cutting dimensions ・・・・・・・・・ page.8 9.Troubleshooting・・・・・・・・・・・・・・・・・・・・・・・・・・ page.9 EC DECLARATION OF CONFORMITY ・・・・・・・・・・・・・・・・・・・ page.10 1.About confirmation of an attachment and a guaranteed period Refer to the following items to check the accessories. (1)SP-832 (according to user’s specifications) ・・・・・1 (2)SP-832 Operation manual・・・・・・・・・・・・・・・・・1 (3)Mounting bracket ・・・・・・・・・・・・・・・・・・・・1 (4)Flange nut ・・・・・・・・・・・・・・・・・・・・・・・2 (5)Unit label ・・・・・・・・・・・・・・・・・・・・・・・1 (6)User-specified accessories. (In the case of the absence of such specification, these accessories are not attached.) NOTE (3)and(4)are installed in the main body. If accessories are insufficient, please contact with an agency or UINICS. About a guaranteed period and a guaranteed area 1.Guaranteed period The period a product guarantees is 1 year from a delivered day. 2.Guaranteed area If we trouble by responsibility in whole guaranteed period, it's repaired without charge at our factory. But if a product conflicted in the following matter, it isn't a guarantee target. Please understand. ① Case of outside of the product specifications. ② Case of User-conducted alterations and modifications of the unit. ③ Case of besides our responsibility. ④ Case of safekeeping and transportation beyond the product specification condition. ⑤ Case due to natural disaster and accident. - 1 - 2.Introduction This product can operate and use the massflow controller with one. This product is integration of the power supply, the adjustment machine, and the display for MFC. A power supply and a necessary signal can be sent and received only by connecting this power supply with the D-SUB cable. The ±15V 200mA power supply of AC 100-240V input type was stored in DIN size 48 × 96mm. There were set machine, a valve open and close switch , and a display in the flont side, and it made it to an easy-to-use layout. NOTE The output of the signal of the VOR (valve open and close swith) of this power supply is a voltage impression method. It is not possible to use it with MFC of a point of contact terminal short method. Valve open or close signal is output by swiching the VOR switch of the flont. The open signal of +15V (Opiton +24V) is output on the open side.The close signal of -15V (Option PS common) is output on the close side. - 2 - 3.Specifications Item Display Digits Decimal point Over scale Sampling Display Accuracy Display value Input resistance Input About 1MΩ Mechanism dial (CMDSET) Mechanism dial with 10 turn function. Minimum value of the scale is 1/50 of 1 turn. Lock lever (Turn and scale are fixed.) Scale of dial is a standard of amount of turn. Command setting Potentiometer (CMDSET) MFC can be set to an arbitrary flowing quantity value. (When it is finished to turn to the right, 5V are output.) Command switch (COMMAND) Switches CONT :(Usually) OPEN :+15V Impressoon to VOR output. (Option +24V) CLOSE:-15V Impressoon to VOR output. (Option P.S.common) EXT:External command input is output to command out. INT:CMDSET is output to command out. Display switch (DISP) SET:Flowing quantity setting value(CMDSET) is displayed. OUT:Flowing quantity output value is displayed from MFC. Span adjustment (SPAN) 20 turn volume is turned from hole on front panel. The maximum display value can be set with in the range from 0-1999, to the 5V in the flowing quantity setting output voltage.(100 is displayed by 5V. in the shipment setting) NOTE: The span setting value of the command setting value and the flowing quantity setting value is the same. Decimal point display setting (DP) Dip switch is operated from hole on front panel. (It light when lowering) Left :1.□□□ Center :1□.□□ Right :1□□.□ MFC COMMAND OUT Voltage DC 0-5V D-SUB External command input DC 0-5V Terminal block VOR switch Operation Specifications Red LED Character height:10mm 3・1/2 digit(up to “1999”) DP-1,2,3 can be selected by selecting the switch. Blinking of “000” (More than “1999”) Approx. 2.5 c/s ±0.2% ±2digit against display. (23℃±5℃) 0V input 000 (-000) 5V input 000…Values arbitrary up to 1999 can be displayed. (Setting by span adjustment) Vor in DC +15V, -15V, (Option +24V) +15V 200mA, -15V 200mA MAX M.F.C power supply (±15V corresponds to 100mA and 300mA) Option +24V 250mA Output COMMAND OUT External signal output DC 0-5V 5mA D-SUB DC 0-5V Terminal block Valve open / close VOR OPEN DC +15V, (Option +24V) output VOR CLOSE DC -15V, (Option PS COMMON) - 3 - AC input AC rated voltage / Rated apparent power AC100-240V 180mA max 50/60Hz About 25 or less VA Weight ・ Dimensions Approx. 400g Mounting panel Others W96 × H48 × D131mm Thickness 1.0 - 4.0mm Panel coutout demensions W92 × H45mm Operating Temperature/ 0-50℃ , 30-80 % RH(Non-condensing) humidity conditions usage environment; Indoor use Up to an altitude of 2,000m operating environment Overvoltage CategoryⅡ Pollution Degree 2 4.Panel mounting method How to mount MFC power supply 1. Cut the panel to insert the MFC power supply from the front. Panel cutout dimensions +0.8 45 -0 +0.5 92 -0 (mm) 2. Flange nut×2 Tighten with the flange nut (Two places) while suppressing it from the back with the mounting brackt. Mounting bracket ・Fit the body on to a panel 1.0 - 4.0 mm in thickness. - 4 - 5.Names and function of components on front 1 2 CONT OPEN CLOSE CMDSET DP 3 ① SPAN COMMAND DISP EXT SET OUT 4 INT 5 7 6 DISPLAY SET value or OUT value is displayed according to the swith of the DISP switch. ② CONT(VOR Switch) VOR Swithch. Valve open and close swicth. ③ DP Decimal point switch. Position of the decimal point is set. ④ SPAN Volume for span adjustment. Maximum display value is arbitrarily set according to the flowing quantity value output voltage.(0-1999) (100 is displayed by 5V. in the shipment setting) ⑤ COMMAND Command switch. An external setpoint signal and the command settting signal are switched. ⑥ DISP Display switch. The display of set value and out value can be switched. ⑦ CMDSET Potentiometers for command adjustment. Flowing quantity setting signal can be fine-tuned by 10 turn function. - 5 - 6.Connecting terminal boards (Rear side) No. Function ① D-SUB 15pin For MFC connection. (HEX-NUT M2.6) ② Mounting bracket Body is fixed at the mount. ③ Flange nut (M4) Bracket is fixed. (Tightening torque 0.6-0.7N/m) It grounds is to earth. ④ AC AC100-240V 50-60Hz AC AC100-240V 50-60Hz NC Please do not connect anything. OPEN Terminal CLOSE block Valve open signal is input from external. Valve close signal is input from external. VOR IN Valve open/close signal is input from external. EXT COMMAND IN Command seting signal is input from external. EXT SIG OUT MFC flowing quantity signal is output external. COMMAND COMMON, OUTPUT COMMON Connects with common. - 6 - 7.MFC connection connectors D-Sub 15Pin(Pin assign) Pin No. Function 1 DC+15V(+24V) Sub-power supply. Capacity is shared with Pin No.13 2 NC(Please do not connect anything.) 3 NC(Please do not connect anything.) 4 NC(Please do not connect anything.) 5 0-5V COMMAND OUT 6 COMMAND COMMON 7 VOR 8 SIGNAL INPUT COMMON 9 EXT VALVE COMMON 10 0-5VSIGNAL INPUT 11 NC(Please do not connect anything.) 12 PS.COMMON 13 DC+15V(+24V) Power supply for MFC 14 DC-15V(PS.COMMON) Power supply for MFC 15 NC(Please do not connect anything.) ( - 7 - )Option 8.External dimensions and panel cutting dimensions External dimensions 96 21 6 131 109 16 CONT OPEN CLOSE 48 CMDSET DP SPAN COMMAND DISP EXT SET OUT INT (mm) When optional C is selected, the terminal cover is attached. Panel cutout dimensions and interval +0.8 -0 70 or more 45 +0.5 -0 92 120 or more (mm) When you mount the machine, please provide a space of at least 20mm from the wall in the direction of up and down, right and left and rear (terminal stand side). - 8 - 9.Troubleshooting Please do the follwing check when abnormality occurs. No. 1 2 Problem Display does not appear at all. Unusual LED lighting Checking point Solution →Is the power supply input normal? Is not the input code short-circuited? NO ↓ ↓ →Damege of internal parts. →Check the power-supply voltage and wiring with the tester, and tighten the screw of the terminal block again. →When a “-” is displayed. →Check the polarity of the signal line. →When a “000” is blinking display. →Check whether the input signal is too large. →have it serviced. →Have it serviced when it is generated many times. 3 Rate meter remains at “0” 4 Display disappears, and it is unstable. 5 Other Problem →Is the setting of the DISP switch correct? ↓ ↓ →Is the input signal normal? ↓ ↓ →Is the position of the COMMAND switch correct? ↓ ↓ NO →The influence of the spark noise generated from the electromagnetic switch, the solenoid, the valve, and the realy is thought. →Check whether to be set at the position where each switch is proper. →The set value is below the range of an effective display. →Check whether to be set at the position where each switch is proper. →Have it serviced →Keep away from the noise source. →Have it serviced - 9 - - 10 - MEMO - 11 - MEMO - 12 - UINICS CO.,LTD. Head Office / Technical TEL:+81-72-274-6001 inquiry FAX:+81-72-274-6005 123-1, Kami, Nishi-Ku, Sakai-shi, Osaka, 593-8311 Japan Tokyo Office TEL:+81-3-5256-8311 FAX:+81-3-5256-8312 All specifications may be changed without notice. - 13 -