Postoperative Astigmatism in the Second Eye Undergoing Cataract Surgery
Transcription
Postoperative Astigmatism in the Second Eye Undergoing Cataract Surgery
CLINICAL SCIENCES Postoperative Astigmatism in the Second Eye Undergoing Cataract Surgery Christopher T. Leffler, MD, MPH; Martin Wilkes, MD; Juliana Reeves, MD; Muneera A. Mahmood, MD, FRCOphth Objective: To predict postoperative refractive astig- matism in the second eye undergoing cataract surgery using standard biometry and information obtained from the first eye. Methods: We conducted a retrospective study of 160 patients undergoing bilateral sequential phacoemulsification with capsular bag implantation of a hydrophobic acrylic lens at a Veterans Affairs medical center. Keratometric and refractive astigmatism were described by Jackson cross cylinder with-the-rule (J0) and oblique (JX) components. Preoperative predictors of postoperative refractive astigmatism in the second eye were determined by multivariable regression. Results: The postoperative refractive astigmatism in the first eye predicted 40% of the variation in the second eye (r2 = 0.40; P ⬍ .001). The multivariable model to predict postoperative with-the-rule astigmatism was A Author Affiliations: Ophthalmology Section, Hunter Holmes McGuire Veterans Affairs Medical Center, and Department of Ophthalmology, Virginia Commonwealth University School of Medicine, Richmond, Virginia. J0PostopEye2 = (0.376 ⫻ J0PostopEye1) ⫹ (0.327 ⫻ J0KeratomEye2) ⫹ (0.097 ⫻ J0PreopEye2) − 0.099 (P ⬍ .001 for first 2 terms; r2 = 0.56). The multivariable model for oblique astigmatism was J X P o s t o p E y e 2 = (0.350 ⫻ J X K e r a t o m E y e 2 ) ⫹ (0.231 ⫻ J X K e r a t o m E y e 1 ) ⫹ (0.064 ⫻ J X P r e o p E y e 2 ) − 0.07 (P ⱕ .01 for first 2 terms; r2 =0.20). Conclusions: Refractive with-the-rule astigmatism observed postoperatively in the first eye is a strong independent predictor of postoperative with-the-rule astigmatism in the second eye. Keratometric oblique astigmatism in the first eye is a weak but statistically significant independent predictor of postoperative oblique astigmatism in the second eye. Both findings are consistent with mirror symmetry of the corneas about the midsagittal plane and may improve the prediction (and hence control) of postoperative astigmatism in the second eye. Arch Ophthalmol. 2011;129(3):295-300 CCURATE PREDICTION OF astigmatism after cataract surgery is becoming increasingly significant owing to the availability and increased use of treatments such as astigmatic keratotomy (including limbal relaxing incisions), toric intraocular lenses, and laser-assisted in situ keratomileusis.1 Each method requires accurate prediction of postoperative astigmatism. The traditional thinking is that keratometry alone determines the postoperative astigmatism because any difference between preoperative keratometric and refractive astigmatism reflects lenticular astigmatism, which is eliminated by lensectomy.2 However, standard keratometry reflects only the anterior paracentral corneal curvature and neglects more peripheral corneal curvature and the entire posterior cornea.3 Indeed, a recent study showed that preoperative refraction, which is influenced by these aspects of corneal curvature, is an independent predictor of postoperative refractive astigmatism.4 Another source of information about postprocedure refraction relies on interocular symmetry. Several reports have (REPRINTED) ARCH OPHTHALMOL / VOL 129 (NO. 3), MAR 2011 295 investigated whether postoperative refraction in the first eye can help to predict spherical refraction in the second eye undergoing laser-assisted in situ keratomileusis5 or cataract surgery.6,7 Corneal curvature,8-14 refractive astigmatism,11,15-17 and pupil center 18 demonstrate mirror interocular symmetry about the midsagittal plane. The purpose of this study was to determine which variables available preoperatively for the second eye, such as keratometry and postoperative refraction in the first eye, were independently predictive of postoperative astigmatism in the second eye. METHODS The study was performed after approval by the institutional review board. Surgical procedures for cataract performed at a Veterans Affairs medical center during a 65-month period from January 1, 2004, to May 31, 2009, were reviewed. Inclusion criteria consisted of bilateral sequential cataract surgery, implantation of a hydrophobic acrylic lens (Acrysof SA60AT lens; Alcon Laboratories, Fort Worth, Texas) in the bag, documentation of keratometry axis and preoperative refraction for both WWW.ARCHOPHTHALMOL.COM ©2011 American Medical Association. All rights reserved. Downloaded From: http://archpsyc.jamanetwork.com/ on 10/15/2014 eyes, and use of the same biometry method (IOL Master system [version 5; Carl Zeiss Meditec, Inc, Dublin, California] or immersion ultrasonography) in both eyes. Exclusion criteria consisted of ophthalmic surgery before cataract surgery, complications during the surgery preventing placement of an intraocular lens in the capsular bag, postoperative macular edema, and postoperative best-corrected visual acuity of less than 20/60 in either eye. Before 2007, biometry was performed using a keratometer (Bausch & Lomb, Rochester, New York). Beginning in 2007, new patients underwent measurements performed with the IOL Master system if clarity of the optical media permitted. All patients underwent phacoemulsification with placement of the acrylic lens in the bag. Multiple residents performed most of the surgical procedures. Selection of a 2.8-mm superior scleral tunnel or a 2.8-mm temporal clear corneal incision was based on the preference of the resident and the supervising attending physician and could differ for first and second eyes. Postoperative refraction was recorded 6 to 8 weeks after the operation. For clear corneal incisions, a triplanar 2.8-mm self-sealing corneal tunnel was prepared with the keratome centered just off the horizontal meridian (eg, at the 8:30 clock position for a right-handed surgeon and a right eye). Stromal hydration was used at the end of the case. For scleral tunnel incisions, light wet-field coagulation was applied, and then a straight incision 2.8 mm wide and approximately 0.5 mm deep was made with the crescent blade, approximately 1.0 mm behind the limbus, centered just off the vertical meridian (eg, at the 11:30 clock position for a right-handed surgeon). A triplanar, self-sealing corneoscleral tunnel 2.8 mm wide was prepared and the anterior chamber was entered. A suture was placed in scleral tunnel incisions if the surgeons believed the wound was at risk of leaking postoperatively. ASTIGMATISM NOTATION All preoperative, postoperative, and expected refractions were converted to the power vector components described by Thibos et al.19,20 In this system, refractions are considered to be the sum of the following 3 components: the spherical equivalent, a Jackson cross cylinder oriented at 180° ( J0), and a Jackson cross cylinder oriented at 45° ( J45). The corneas display mirror symmetry; thus, an axis of 45° in the right eye has the same anatomic orientation with respect to the eyelids and other facial structures as an orientation of 135° in the left eye.17,21 Therefore, oblique astigmatism, JX, was defined as JX =J45 for the right eye and JX =−J45 for the left eye. In this article, J0 is referred to as quantifying with-the-rule astigmatism (although if J0 is negative, the patient has against-the-rule astigmatism). If the astigmatic portion of a refraction includes a cylinder of power C with axis 1, the cross cylinders are calculated with the following equations19,20: J0 =−(C/2)cos(21) and J45 =−(C/2)sin(21). For instance, if a refraction is ⫹5.00 ⫹ 3.00 ⫻ 100, then C=⫹3.00, 1 =100, J0 =1.41 diopters (D), and J45 =0.51 D. Once the postoperative spherical equivalent (M), J0, and J45 are predicted, they are converted to a refraction in positive cylinder notation (S, ⫹C⫻B°) using the following equations19,20: C=2冑( J02 ⫹J452), S=M−C/2, and B=0.5tan−1( J45/J0)⫹90°. STATISTICAL EVALUATION Predictors of the postoperative astigmatic components ( J0 and JX) in the second eye were determined by means of univariate and multivariable linear regression analysis. Independent variables analyzed included age, preoperative refractive and keratometric astigmatism in both eyes, and mean preoperative keratometry readings. Nonsignificant variables were removed by stepwise backward regression analysis. We used commercially available software (Statistica, version 7; StatSoft, Inc, Tulsa, Oklahoma) to generate the regression coefficients (m values), coefficient of determination (r2 values), and statistical significance (P values). To express the model fit in the familiar unit of diopters, the square root of the mean squared (RMS) error was calculated. The squared error for each patient was C2 =4[( J0Observed −J0Expected)2 ⫹( J45Observed −J45Expected)2]. The RMS error is appropriate for assessing standard least squares regression, which minimizes the squared error. Keratometric astigmatism will have a greater effect in the spectacle plane for myopic eyes, and a lesser effect in the spectacle plane for hyperopic eyes.3,22 However, after cataract surgery, patients are close to emmetropia; therefore, keratometric astigmatism is almost unchanged when translated to the spectacle plane for typical data sets.4 A related question is whether astigmatism in the preoperative refraction, which deviates more from emmetropia, can be moved to the corneal plane. The present study addressed this question using standard formulas for vertexing spherocylinders to the corneal plane.3 For analysis of with-the-rule astigmatism, incision location was coded as 1 for superior, −1 for temporal, or 0 for not applicable. For analysis of oblique astigmatism, the incision location quadrant was estimated on the basis of surgeon handedness (eg, a right-handed surgeon performing a superior scleral tunnel incision on a right eye would be expected to produce an incision centered in the superotemporal quadrant) and was coded as 1 for the superonasal or inferotemporal quadrants, −1 for the superotemporal quadrant, and 0 for not applicable. RESULTS The second eyes of 160 patients who underwent bilateral sequential phacoemulsification were included in the study. Of these patients, 156 (97.5%) were male, and 40 (25.0%) were black. The mean (SD) age was 71.3 (9.9) years. Manual keratometry was used for both eyes in 102 patients (63.8%), and the IOL Master system was used in both eyes in the remainder. The following linear regression showed that the preoperative refractive cylinder power could be moved to the corneal plane without substantial modification: C (in the corneal plane) =0.001⫹ 0.981C (in the spectacle plane; r2 =0.987). Preoperative and postoperative refraction reflected a small amount of against-the-rule astigmatism on average (J0 ⬍ 0; Table 1). For each measure, there was interpatient variability (SD of J0, 0.40-0.49). There was less oblique astigmatism in the keratometry and refraction, as indicated by the smaller mean and SD values for JX (Table 1). Most patients (95.0%) had an absolute difference of preoperative keratometric astigmatism magnitude of 1.13 D or less and of mean keratometry of 0.85 D or less. The univariate predictors of postoperative with-therule astigmatism ( J0) in the second eye included age, preoperative refractive and keratometric astigmatism (REPRINTED) ARCH OPHTHALMOL / VOL 129 (NO. 3), MAR 2011 296 WWW.ARCHOPHTHALMOL.COM ©2011 American Medical Association. All rights reserved. Downloaded From: http://archpsyc.jamanetwork.com/ on 10/15/2014 Table 1. Refractive and Keratometric Data for the Second Eye Undergoing Surgery Mean (SD), D Preoperative keratometry Preoperative refraction Postoperative refraction SE J0 JX 43.50 (1.30) −0.70 (2.43) −0.25 (0.71) −0.03 (0.53) −0.25 (0.49) −0.21 (0.40) −0.02 (0.22) −0.001 (0.33) −0.07 (0.23) Abbreviations: D, diopter; J0, with-the-rule astigmatism; JX, oblique astigmatism; SE, spherical equivalent. Table 2. Predictors of Postoperative Refractive J0 in the Second Eye Multivariable Analysis a Univariate Analysis Age First eye Preoperative refraction, J0 Preoperative keratometry, J0 Postoperative refraction, J0 Second eye Unsutured incision location b Sutured incision location b Preoperative refraction, J0 Preoperative keratometry, J0 Multivariable model intercept m Value Intercept r 2 Value P Value m Value P Value −0.011 0.54 0.07 ⬍.001 ... ... 0.401 0.477 0.705 −0.10 −0.20 −0.06 0.21 0.30 0.40 ⬍.001 ⬍.001 ⬍.001 ... ... 0.376 ... ... ⬍.001 −0.065 0.011 0.370 0.518 ... −0.21 −0.22 −0.12 −0.20 ... 0.02 ⬍0.001 0.21 0.47 ... .08 .87 ⬍.001 ⬍.001 ... ... ... 0.097 0.327 −0.099 ... ... .053 ⬍.001 ⬍.001 Abbreviations: ellipses, not applicable; J0, with-the-rule astigmatism; m, linear regression coefficient. a Multivariable model r 2 =0.56. b Coded as 1 for superior, −1 for temporal, and 0 for not applicable. (J0) in both eyes, and postoperative refractive astigmatism ( J0) in the first eye (all P ⬍ .001; Table 2). The best predictors were the preoperative keratometric astigmatism in the second eye (r2 =0.47) and the postoperative refractive astigmatism in the first eye (r2 = 0.40; Table 2 and Figure). The following multivariable model predicted postoperative with-the-rule astigmatism in the second eye: J0PostopEye2 = (0.376 ⫻ J0PostopEye1 ) ⫹ (0.327 ⫻ J0KeratomEye2 ) ⫹(0.097⫻J0PreopEye2)−0.099, where P ⬍ .001 for the first 2 terms, and the model r2 =0.56 (Table 2). The univariate predictors of postoperative oblique astigmatism (JX) in the second eye included the preoperative keratometric astigmatism ( JX) in both eyes (both P⬍.001) and the preoperative refractive astigmatism (JX) in the second eye (P = .007; Table 3). The best predictors were the preoperative keratometric astigmatism in the second eye (r2 = 0.16) and in the first eye (r2 =0.07; Table 3). We used the following multivariable model for postoperative oblique astigmatism in the second eye: JXPostopEye2 = (0.350 ⫻ JXKeratomEye2) ⫹ (0.231 ⫻ JXKeratomEye1) ⫹(0.064⫻JXPreopEye2) − 0.07, where Pⱕ.01 for the first 2 terms, and the model r2 =0.20 (Table 3). When analyses were conducted with J45 instead of JX, refractive and keratometric J45 values in the first eye were negatively associated with postoperative refractive J45 in the second eye, consistent with mirror symmetry of the corneas.17 The RMS error for keratometry alone was 0.72 D. The RMS error for the multivariable models incorporating contralateral eye information in Table 2 and Table 3 was 0.67 D, a reduction of 6.8%. PREDICTIVE VALUE OF INCISION LOCATION In all, 106 patients (66.2%) had superior scleral tunnel incisions. Of these, 43 (40.6%) had a suture and 68 (64.2%) had the same approach in the first eye. Of the 54 patients with a clear corneal incision, 29 (53.7%) had the same approach in the first eye. Unsutured incisions were associated with a small amount of flattening in the axis of the incision, although the changes were not statistically significant (P ⱖ .08; r2 ⱕ 0.02; Table 1 and Table 2). Sutured incisions had on average no effect on the corneal curvature and no ability to predict refraction (r2 ⬍0.001), although the standard errors for the regression coefficients were 50% to 75% greater than those for the unsutured incisions. This result was consistent with more variability in the effect of sutured incisions. Multivariable models incorporating incision location confirmed the value of the contralateral eye information. For instance, a conventional model incorporating preoperative keratometry for the second eye and sutured and unsutured incision location had an r2 value of 0.47 for prediction of postoperative J0 in the second eye, and only the keratometric term was significant (P⬍ .001). Addition of information from the first eye (postoperative refractive astigmatism [J0; P ⬍ .001] and incision location) to the model improved the r2 value to 0.57. For (REPRINTED) ARCH OPHTHALMOL / VOL 129 (NO. 3), MAR 2011 297 WWW.ARCHOPHTHALMOL.COM ©2011 American Medical Association. All rights reserved. Downloaded From: http://archpsyc.jamanetwork.com/ on 10/15/2014 P⬍ .01 for the first 2 terms, P =.58 for the J0PreopEye2 term, and the model r2 =0.62. In these patients, the multivariable model for postoperative oblique astigmatism in the second eye was J XPostopEye2 = (0.449 ⫻ J XKeratomEye2 ) ⫹ (0.231 ⫻ JXKeratomEye1) ⫹ (0.033 ⫻ JXPreopEye2) − 0.09, where Pⱕ.001 for JXKeratomEye2, P=.05 for JXKeratomEye1, P=.72 for JXPreopEye2, and the model r2 =0.36. Compared with ipsilateral preoperative keratometry alone, with an RMS error of 0.77 D, the multivariable models improved the RMS error to 0.67 D. Postoperative Refractive J0 in Eye 2, D 1.5 1.0 0.5 0.0 – 0.5 – 1.0 y = 0.705 × – 0.06 r ² = 0.40 – 1.5 – 2.0 – 1.5 – 1.0 – 0.5 0 0.5 COMMENT 1.0 Postoperative Refractive J0 in Eye 1, D Figure. Association of postoperative refractive with-the-rule astigmatism ( J0) in the first and second eyes. D indicates diopters. oblique astigmatism, the corresponding conventional model had an r2 value of 0.17, with only the keratometric term significant (P ⬍.001). Addition of keratometry in the first eye (P = .03) and incision location improved the r2 value to 0.21. The RMS error of the conventional model was 0.75 D, and the addition of the information from the first eye improved the RMS error to 0.70 D, a reduction of 7.1%. The right eye was the second eye to have surgery in 39.4% of the cases. Laterality of surgery in the second eye was not predictive of postoperative refractive astigmatism ( J0, P = .83; r2 = 0.0003; m = 0.01 D) ( JX, P = .09; r2 =0.02; m=−0.06 D). Among the surgical procedures in the second eye, 64.4% were performed by a righthanded surgeon. Right-handedness was a weak predictor of postoperative refractive astigmatism in univariate analyses ( J0, P = .05; r2 = 0.02; b = 0.13 D) ( JX, P = .03; r2 = 0.03; b = −0.08 D) but, after controlling for ipsilateral keratometry, this relationship was not significant (P=.17 for J0; P = .07 for JX). SUBGROUP ANALYSIS Similar findings were seen in subgroup analysis. In the 102 patients undergoing manual keratometry for both eyes, the multivariable model to predict postoperative with-the-rule astigmatism in the second eye was J0PostopEye2 = (0.254 ⫻ J0PostopEye1) ⫹ (0.367 ⫻ J0KeratomEye2) ⫹ (0.123⫻J0PreopEye2) − 0.126, where P⬍ .01 for the first 2 terms, P=.06 for the J0PreopEye2 term, and the model r2 =0.55. For these patients, the multivariable model for postoperative oblique astigmatism in the second eye was JXPostopEye2 = (0.225 ⫻ JXKeratomEye2) ⫹ (0.204 ⫻ JXKeratomEye1) ⫹ (0.074⫻JXPreopEye2) − 0.05, where the P values for terms 1 to 3 were .06, .19, and .28, respectively, and the model r2 = 0.08. Compared with ipsilateral preoperative keratometry alone, with an RMS error of 0.68 D, the multivariable models improved the RMS error to 0.65 D. In the 58 patients for whom the IOL Master system was used for both eyes, the multivariable model to predict postoperative with-the-rule astigmatism in the second eye was J 0 P o s t o p E y e 2 = (0.606 ⫻ J 0 P o s t o p E y e 1 ) ⫹ (0.251⫻ J0KeratomEye2) ⫹(0.043⫻J0PreopEye2) − 0.047, where This study demonstrated that the postoperative refractive with-the-rule astigmatism in the second eye having cataract surgery is predicted by that in the first eye, independent of preoperative keratometry. Moreover, the preoperative keratometric oblique astigmatism in the first eye independently predicts postoperative refractive oblique astigmatism in the second eye, although this association is weaker. The astigmatic predictions represent incremental improvements over ipsilateral keratometry alone. For instance, the absolute increase in the explained variation in with-the-rule astigmatism was 9% (with the r2 value improving from 0.47 to 0.56). Both findings depend on interocular symmetry, which also underlies other algorithms for using the postoperative refraction in the first eye to improve refractive predictions in the second eye.5-7 Although there has been some debate about whether corneal shape and refraction exhibit predominantly direct or mirror symmetry,23 our results add to the body of literature demonstrating mirror symmetry of the corneas about the midsagittal plane.8-17,21 Indeed, mirror symmetry is expected in bilateral organs16 and is observed, at least grossly, in other features of eye anatomy, such as extraocular muscles and retinal organization.24 For the corneas, this symmetry may result from genetic factors or from corresponding symmetry of facial structure or eyelid orientation, extraocular muscle tension, or other developmental factors.21,25 Because 95% of the patients had an interocular difference in keratometry readings of less than 0.85 D mean and less than 1.13 D astigmatism magnitude, the method should not be applied for patients with a greater degree of interocular asymmetry until additional data are available. The very small impact of incision location on refractive astigmatism may be surprising but is consistent with a previous study by our group.4 Unsutured incisions typically produce flattening in the axis of the incision,26,27 although the effect is less prominent with smaller incisions.28,29 In a randomized trial comparing a 3.0-mm unsutured superior scleral tunnel incision vs a 3.0-mm unsutured temporal clear corneal incision in patients with at least 0.5 D of against-the-rule astigmatism, the difference between groups in keratometric against-the-rule astigmatism at 1 month was 0.18 D, but there was no group difference in uncorrected visual acuity.30 Refractive astigmatism, which was assessed in the present study (REPRINTED) ARCH OPHTHALMOL / VOL 129 (NO. 3), MAR 2011 298 WWW.ARCHOPHTHALMOL.COM ©2011 American Medical Association. All rights reserved. Downloaded From: http://archpsyc.jamanetwork.com/ on 10/15/2014 Table 3. Predictors of Postoperative Refractive JX in the Second Eye Multivariable Analysis a Univariate Analysis First eye Preoperative refraction, JX Preoperative keratometry, JX Postoperative refraction, JX Second eye Unsutured incision location b Sutured incision location b Preoperative refraction, JX Preoperative keratometry, JX Multivariable model intercept m Value Intercept r 2 Value P Value m Value P Value 0.010 0.326 0.105 −0.07 −0.07 −0.07 ⬍0.01 0.07 0.01 .86 ⬍.001 .17 ... 0.231 ... ... .01 ... 0.028 0.001 0.154 0.422 ... −0.08 −0.08 −0.07 −0.06 ... 0.01 ⬍0.001 0.05 0.16 ... .22 .99 .007 ⬍.001 ... ... ... 0.064 0.350 −0.070 ... ... .23 ⬍.001 ⬍.001 Abbreviations: ellipses, not applicable; JX, oblique astigmatism; m, linear regression coefficient. a Multivariable model r 2 =0.20. b Coded as 1 for superonasal or inferotemporal, −1 for superotemporal, and 0 for not applicable. and is most important clinically, may not always match keratometric changes because of an opposing effect of the posterior or peripheral cornea. Small effects might be more difficult to define with statistical certainty when there is inconsistency due to the involvement of multiple resident surgeons. In the present study, the incisions that were sutured owing to concern about postoperative leaking probably might have produced a greater than average degree of flattening if left unsutured. Sutured incisions had a net null effect on astigmatism, although there was variability, because the incision might produce flattening or steepening depending on suture tightness.31,32 The degree of astigmatism induced by the incision will likely assume an even smaller role as practices transition to incisions close to 2 mm.33,34 Ideally, surgeons should estimate the surgically induced astigmatism within their own practice. If confirmed, the regression equations could be used to predict refraction after cataract surgery in the second eye. The findings may be specific to our particular practice, consisting mostly of male patients and multiple surgeons in a teaching environment. In addition, the findings are based on retrospective calculations. The next step in evaluating the clinical value of this strategy would be a prospective randomized trial of adjusting astigmatism control in the second eye on the basis of refractive results in the first eye vs standard care. The uncorrected near and far visual acuity would be an important end point. In studies of toric intraocular lenses, the benefit might be reduced by the fact that lenses are available in discrete increments. Based on the present study, when astigmatism control is contemplated along with cataract surgery, consideration should be given to delaying surgery in the second eye until an accurate postoperative refraction can be obtained in the first eye. An unexpected refractive astigmatic outcome in the first eye should prompt a close evaluation of possible causes, including the influence of posterior or peripheral corneal curvature, which might also be manifested in the results in the second eye. Submitted for Publication: March 15, 2010; final revision received July 13, 2010; accepted July 13, 2010. Correspondence: Muneera A. Mahmood, MD, FRCOphth, Eye Clinic, Room 112, Hunter Holmes McGuire Veterans Affairs Medical Center, 1201 Broad Rock Blvd, Richmond, VA 23249 ([email protected]). Financial Disclosure: None reported. REFERENCES 1. Nichamin LD. Astigmatism control. Ophthalmol Clin North Am. 2006;19(4):485493. 2. Chang DF. Pearls for implanting the Staar toric IOL. Br J Ophthalmol. 2001;85(1) (suppl). http://bjo.bmj.com/cgi/content/full/85/1/DC1. Accessed August 7, 2007. 3. Holladay JT, Moran JR, Kezirian GM. Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism. J Cataract Refract Surg. 2001;27(1):61-79. 4. Leffler CT, Javey G, Mahmood MA. Prediction of postoperative astigmatism in cataract surgery. Can J Ophthalmol. 2008;43(5):551-554. 5. Chiang PK, Hersh PS. Comparing predictability between eyes after bilateral laser in situ keratomileusis: a theoretical analysis of simultaneous versus sequential procedures. Ophthalmology. 1999;106(9):1684-1691. 6. Jabbour J, Irwig L, Macaskill P, Hennessy MP. Intraocular lens power in bilateral cataract surgery: whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye. J Cataract Refract Surg. 2006; 32(12):2091-2097. 7. Covert DJ, Henry CR, Koenig SB. Intraocular lens power selection in the second eye of patients undergoing bilateral, sequential cataract extraction. Ophthalmology. 2010;117(1):49-54. 8. Dingeldein SA, Klyce SD. The topography of normal corneas. Arch Ophthalmol. 1989;107(4):512-518. 9. Smolek MK, Klyce SD, Sarver EJ. Inattention to nonsuperimposable midline symmetry causes wavefront analysis error. Arch Ophthalmol. 2002;120(4):439-447. 10. Boote C, Hayes S, Abahussin M, Meek KM. Mapping collagen organization in the human cornea: left and right eyes are structurally distinct. Invest Ophthalmol Vis Sci. 2006;47(3):901-908. 11. Kelly JE, Mihashi T, Howland HC. Compensation of corneal horizontal/vertical astigmatism, lateral coma, and spherical aberration by internal optics of the eye. J Vis. 2004;4(4):262-271. 12. Myrowitz EH, Kouzis AC, O’Brien TP. High interocular corneal symmetry in average simulated keratometry, central corneal thickness, and posterior elevation. Optom Vis Sci. 2005;82(5):428-431. 13. Read SA, Collins MJ, Carney LG. The influence of eyelid morphology on normal corneal shape. Invest Ophthalmol Vis Sci. 2007;48(1):112-119. 14. Misson GP. Circular polarization biomicroscopy: a method for determining human corneal stromal lamellar organization in vivo. Ophthalmic Physiol Opt. 2007; 27(3):256-264. 15. Hofstetter HW, Baldwin W. Bilateral correlation of residual astigmatism. Am J Optom Arch Am Acad Optom. 1957;34(7):388-391. 16. Solsona F. Astigmatism as a congenital, bilateral and symmetrical entity (observations based on the study of 51,000 patients). Br J Physiol Opt. 1975;30(2-4): 119-127. (REPRINTED) ARCH OPHTHALMOL / VOL 129 (NO. 3), MAR 2011 299 WWW.ARCHOPHTHALMOL.COM ©2011 American Medical Association. All rights reserved. Downloaded From: http://archpsyc.jamanetwork.com/ on 10/15/2014 17. Guggenheim JA, Zayats T, Prashar A, To CH. Axes of astigmatism in fellow eyes show mirror rather than direct symmetry. Ophthalmic Physiol Opt. 2008;28 (4):327-333. 18. Lu F, Wu JX, Qu J, et al. Association between offset of the pupil center from the corneal vertex and wavefront aberration. J Optom. 2008;1(1):8-13. doi:10.3921 /joptom.2008.8. 19. Thibos LN, Wheeler W, Horner D. Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error. Optom Vis Sci. 1997;74(6):367-375. 20. Thibos LN, Horner D. Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg. 2001;27(1):80-85. 21. Garcia ML, Huang D, Crowe S, Traboulsi EI. Relationship between the axis and degree of high astigmatism and obliquity of palpebral fissure. J AAPOS. 2003; 7(1):14-22. 22. Elliott M, Callender MG, Elliott DB. Accuracy of Javal’s rule in the determination of spectacle astigmatism. Optom Vis Sci. 1994;71(1):23-26. 23. McKendrick AM, Brennan NA. The axis of astigmatism in right and left eye pairs. Optom Vis Sci. 1997;74(8):668-675. 24. Enoch JM. The relationship between retinal receptor orientation and photoreceptor optics. Int Ophthalmol Clin. 1978;18(2):41-80. 25. Read SA, Collins MJ, Carney LG. A review of astigmatism and its possible genesis. Clin Exp Optom. 2007;90(1):5-19. 26. Cillino S, Morreale D, Mauceri A, Ajovalasit C, Ponte F. Temporal versus supe- 27. 28. 29. 30. 31. 32. 33. 34. rior approach phacoemulsification: short-term postoperative astigmatism. J Cataract Refract Surg. 1997;23(2):267-271. Goes FM Jr, Goes FJ. Astigmatic changes after sutureless small-incision cataractsurgery using a superior or temporal corneal incision. Bull Soc Belge Ophtalmol. 1998;268:27-32. Dam-Johansen M, Olsen T. Induced astigmatism after 4 and 6 mm scleral tunnel incision: a randomized study. Acta Ophthalmol Scand. 1997;75(6):669-674. Beltrame G, Salvetat ML, Chizzolini M, Driussi G. Corneal topographic changes induced by different oblique cataract incisions. J Cataract Refract Surg. 2001; 27(5):720-727. Oshima Y, Tsujikawa K, Oh A, Harino S. Comparative study of intraocular lens implantation through 3.0 mm temporal clear corneal and superior scleral tunnel self-sealing incisions. J Cataract Refract Surg. 1997;23(3):347-353. Gimbel HV, Sun R, DeBroff BM. Effects of wound architecture and suture technique on postoperative astigmatism. Ophthalmic Surg Lasers. 1995;26(6):524-528. Azar DT, Stark WJ, Dodick J, et al. Prospective, randomized vector analysis of astigmatism after three-, one-, and no-suture phacoemulsification. J Cataract Refract Surg. 1997;23(8):1164-1173. Masket S, Wang L, Belani S. Induced astigmatism with 2.2- and 3.0-mm coaxial phacoemulsification incisions. J Refract Surg. 2009;25(1):21-24. Hayashi K, Yoshida M, Hayashi H. Postoperative corneal shape changes: microincision versus small-incision coaxial cataract surgery. J Cataract Refract Surg. 2009;35(2):233-239. Topic Collections. Archives offers collections of articles in specific topic areas to make it easier for physicians to find the most recent publications in a field. These are available by subspecialty, study type, disease, or problem. In addition, you can sign up to receive a Collection E-Mail Alert when new articles on specific topics are published. Go to http://archopht.ama-assn.org/collections/ to see these collections of articles. (REPRINTED) ARCH OPHTHALMOL / VOL 129 (NO. 3), MAR 2011 300 WWW.ARCHOPHTHALMOL.COM ©2011 American Medical Association. All rights reserved. Downloaded From: http://archpsyc.jamanetwork.com/ on 10/15/2014